Network error 10060 client timed - for only a particular Application!

Hi All,
I'm getting the following error when I try to connect to Essbase from Excel sheet but for only a particular Application & Database:
network error [10060]: Unable to connect to [server_name_xxx:1423]. the client timed out waiting to connect to essbase agen TCP/IP........
I'm able to connect to other applications/dbs residing on the same server. But I get this error only for this particular application.
Kindly help.
Thanks.

you will receive this error if the data cannot be retrieved within the appropriate timeout window. If your query is big, or you have less/no aggregations on the cube (ASO) , Addin will wait upto certain period and throw time out error. You can try following tips
1. Change essbase.cfg file. Increase "NETDELAY" and "NETRETRY COUNT" to 300000 ( 5 mins) and restart services.
2. Open registry editor in you mechine and navigate to "HKEY_CURRENT_USER\Software\Microsoft\Windows\CurrentVersion\Internet Settings" and add/edit the following DWord items:
ReceiveTimeout 300000
KeepAliveTimeout 300000
ServerInfoTimeout 300000
* note: The timeout values in the registry are in milliseconds. So 300000 is the equivalent of 5 minutes
Is your application is a BSO or ASO?

Similar Messages

  • Network Error in Client Full System Restore

    Hi,
    I've been attempting, as a test, to restore a full system backup to a client computer using a boot flash drive. When I attempt to do so, I get a "Unknown Network Error" at the point where the client has attempted to contact the server, been unable
    to and offered the opportunity to enter a name or an IP address. When I enter either one, I immediately get an "Unknown Network Error". There's no error number or other specific identifying informations.
    Details:
    The client computer is a UEFI motherboard PC running Windows 7 Professional. It connects with no difficulty whatsoever on a normal basis to the Windows 2012 R2 Essentials server. It gets backed up every night by the server over the network with no problem.
    When I boot from the Network Client Computer Restore USB key, everything works fine except that it is unable to find network drivers. When given the chance to load missing drivers, I use the "Drivers for Full System Restore (from the full system backup)"
    on another USB key and they are found just fine.
    Then when we get to the point of searching for the server, it appears to look for 30 seconds or so, then a dialog comes up asking whether to search again or if I want to enter a IP or name. Searching again doesn't yield results, and when either an IP or
    the server name is entered, I get the "Unknown Network Error".
    I feel certain there must be some logging that is either available or could be turned on if I knew how. I feel concerned that I would not be able to restore my client computer if something were to happen. Any ideas would be greatly appreciated.
    Jeff

    Hi Justin,
    Thanks for your response. I'm sorry that I didn't see it sooner - I guess I assumed I'd get an email if there was a response...
    Anyway, at the time when the error occurs, the OS is not running. We have just booted via PXE over the network and started the "Full System Restore" Wizard, so it is not possible to "ping" the server. However, the fact that we successfully
    booted via PXEs tells me that basic connectivity exists to the server, because otherwise the PXE boot wouldn't work.
    Thanks for the pointer to the logs - I'll check them.
    What I have done since I last updated was to do a few experiments. I added a Windows 7 boot image and install image with the Windows Distribution Service, so that on PXE boot I'm given 2 options - a Full System Restore and a Software Install.
    I also roped another PC into service, one that is running from BIOS rather than UEFI. On that PC, both the System Restore and Software Install via PXE boot work fine. This tells me the server is at least nominally working, and that the problem is related
    somehow to the specifics of the PC being connected. Could be server setup still, could be something on the PC.
    On the computer with the UEFI, neither Full System Restore nor Software Install works. However, there is at least a clue in the error response from the Windows Setup - I get a lengthy error message that essentially says that \Windows\Boot\EFI\bootmgr.EFI
    is corrupted. I'm not clear whether at this point we are referring to a file extant on the PC or one that is being downloaded that's being claimed to be corrupted.
    This took me down a path in which, to eliminate variables, I changed the boot drive on the UEFI system from MBR to GPT. No joy. Also broke up my mirrored drive and changed the SATA from RAID back to AHCI. Also no joy. But everything I am reading is leading
    me to believe that the problem has to do with the fact that my target PC has a UEFI BIOS. I continue to investigate - and will look through the logs you mention.
    Jeff
    Update 8/24/2014
    Made some progress yesterday. I'm now able to use Windows Deployment Service to deploy Windows 7 over the network to the UEFI computer. I had to do two things to get that to work.
    Turn off driver signing in the UEFI bios. That got me past the error screen complaining about a corrupted driver (which I'm pretty sure I don't have). But then it got hung up saying it couldn't find a driver for the network.
    To fix that, I added the driver package to the boot image using the tools in the Windows Deployment Service applet.
    After that, it found the server just fine, allowed me to authenticate, and would have proceeded to install Windows 7 if I hadn't aborted.
    I then added the exact same driver package to the Full System Restore boot image, but it made absolutely no difference. Exactly the same symptoms as reported previously.
    So, where am I and what do I know?
    I can do both a Remote Windows 7 install and Client Full System Restore using Windows Deployment Services on an X64, BIOS based computer.
    I can do a Remote Windows 7 install to my X64 UEFI based computer.
    When I attempt a Client Full Restore to the X64 UEFI computer, I get all the way to the Full System Restore Wizard, which tells me that it can't find network drivers (even when they've been installed to the boot image). It finds network drivers when provided
    via a USB key, but then when the Wizard looks for the server, it's unable to find it. When a manual option is presented, and I enter the server's IP address, I get an "Unknown Network Error" popup message, and I can't proceed further.
    On the UEFI computer, I've tried all combinations of Compatibility Support Module (CSM) settings, but they make absolutely no difference to the Full System Restore process.
    I've also tried converting the boot disk from MBR to GPT, didn't make any difference.
    I "unmirrored" my mirrored RAID drives and changed the SATA bios from RAID to AHCI. Made no difference.
    So, at this point I'm kind of stuck. I'm out of ideas for things to try for now. I did look at the logs as suggested, but didn't see much of anything relative to WDS. Possibly logging has to get turned on?
    As always, any help or ideas would be much appreciated.
    Jeff

  • Errors generating client stubs for web services

    Hello,
    We are having issues trying to generate client stubs from the Unifier wsdl document (mainservice.wsdl). I see this was generated using Axis 1.4 (2006). I normally use Apache CXF but it complains due to the use of RPC/encoding. I tried Axis2 but it complains about "SchemaCompilationException: can not find type {http://schemas.xmlsoap.org/soap/encoding/}Array from the parent schema". I am wondering if we need to use Axis 1.4?
    If you have successfully generated client stubs from the wsdl documents please let me know which method was successful for you.
    We have Unifier R9.12 installed.
    Thank you
    Rudy

    I found more notes on what I had to do:
    - the process above created package names like java.oracle_e1_bssv_jp010000
    - we need to rename these to be proper package names.
    - refresh the eclipse project so you see these folders
    - select the package, right click, refactor, rename
    - rename these to be like oracle.e1.bssv.jp010000 (remove the java. and replace _ with .)
    - there will probably be a bunch of errors in individual java files you will need to fix.
    - they are very easy, it should be a matter of just deleting the imports, these are not needed because they are in the same package.

  • Error during client copy in GRC 10.0 -Application exit

    Hello Experts,
    After installing GRC 10.0,as post installation activity ,
    we are doing client copy (accordence with the sap note 1505255).
    but we are getting  'Application Exit Error' when executing method FDT_BEFORE_EXPORT_C:
    any help would be appreciated.
    regards,
    vinay singh

    HI
    Can you attach client copy log for analysis.
    Regards
    Rajan Arora

  • Item condition for only one particular sales order type, manual condition.

    Hi Gurus
    We have one condition ZXXX, item condition and it should process manually for one particular order type, ZOR. it should not process for other document types like ZOR1 etc.
    i did create condition table with S.org/dis chn/div/ sales.doc type. and kept in access seq. and same in condition type ZXXX. and mainatined condition record as with sales area and doc type ZOR.
    condition type settings ate like item condition and manaula entries - no limitation.
    in pricing procedure i didnt checked manaul, mandoatry and statistic.
    but whn iam craeting in ZOR1 and giving manually condition ZXXX, its accepting but as per our condition record it should get only for ZOR... where iam missing the seeting, please suggest.
    Thanks
    Ramki

    Hi Ram,
    In my point of view i think so you have to create the new document pricing procedure.
    after creating that you have maintain new item catergory determination procedure using the new document pricing procedure created before.
    assign this document pricing procedure to your ZOR document type.
    now create new pricing procedure by copying the standard one.
    after that do the assigning procedure for the pricing procedure by using the new document pricing procedure.
    then try to create the order with ZOR and also with ZOR1
    Make sure that your condition type is not assign to any other pricing procedure.
    if it happens then let me know also.
    Suneet Prakash

  • Hide Portal Favorites for only a particular iView

    Hello,
    Can we hide Portal Favorites in Navigation Panel for a particular iView and whenever requires we can open the Portal Favorites for that iView.
    Please suggest. Thank You.
    Regards,
    Sridhar.

    Hi,
    You can hide the detailed navigation pannel for a particular page, but user will be able to re-open it via a click on "expand detailed navigation menu".
    You can not delete the favorites part for just one iview/page, as it is configured on the portal framework.
    You can decide that the iview can not be added to portal's favorite (it is an iview option).
    Fabien.

  • How does labview opc communication with plc affect timing for the actual plc application

    Hi Everyone, 
    I have a doubt and thus want to start a discussion regarding communication with PLC's from NI OPC server.
    Let's imagine you have a production machine like a caping machine for a bottle production line, let's say the PLC on this machine is a Siemens S7300 which according to NI is compatible with NI OPC server.
    The PLC would have already been programmed by the company who sells the machine to control it correctly.
    The question is, if you'd like to add an interface, and all the capabilities that LabVIEW offers to this machine by controlling/monitoring its PLC, returning its alarms etc...
    In that configuration is there a possibility that the LabVIEW application you would devellop affects the PLC's Behaviour and thus the machine functionality or yield and thus would have a negative impact?
    Thanks a lot for your answers.
    Best Regards,

    Hi Olivioloyer Good Morning:
    The issue here is that if you want to control, display and log data and funcionality from that PLC through LabVIEW you will have to change the program on the PLC to work correctly with your Interface and Alarming program that you will create in LabVIEW. If you develop a well designed architecture and an efficient code there will be no negative impact on yout PLC, on the contrary you will expand the funcionality and capability of your application. 
    Note: You will need to change your PLC program to achieve correct functionality with what your LabVIEW code will do.(Send and receive control commands). If you just want to monitor your PLCs behaviour, your code will be much more simple and maybe no change will be required on the PLCs program.
    Juan Arguello
    National Instruments México y Latinoamérica
    Applications Engineer

  • Essbase Error (1042017): Network Error in Smart View

    I try to do Ad hoc ahalysis in Smart View via Essbase provider and get Essbase Error (1042017): Network Error: The client or server timed out waiting to receive data using TCP/IP. Check network connections. Increase the olap.server.netConnectRetry and/or olap.server.netDelay values in the essbase.properties.
    I've tried to increase this values in essbase.properties file in C:\Oracle\Middleware\EPMSystem11R1\products\Essbase\aps\bin directory and in Essbase Administration Services console but it has no effect. This behaviour occur only for one application. Early I has no problem with this.
    How this can be fixed?

    Please follow the steps below:
    1) Add the following parameters to the mod_wl_ohs.conf for APS within the aps location match section:
    WLIOTimeoutSecs 1800
    Idempotent OFF
    For Example:
    <LocationMatch ^/aps/>
    SetHandler weblogic-handler
    WeblogicCluster vm0asazon1112:13080
    WLIOTimeoutSecs 1800
    Idempotent OFF
    </LocationMatch>
    Note: mod_wl_ohs.conf file is located in <drive>:\<Oracle_EPM_Home>\Middleware\user_projects\epmsystem1\httpConfig\ohs\config\OHS\ohs_component directory.
    Make a back up copy of the mod_wl_ohs.conf file before editing.
    2) Save the mod_wl_ohs.conf
    3) Restart Reporting and Analysis Framework - Web Application
    4) Restart Oracle Process Manager (ohsInstancexxxxxxxxxx)
    For more details on the Weblogic Plug-ins parameters, please refer to this link: http://download.oracle.com/docs/cd/E13222_01/wls/docs92/pdf/plugins.pdf
    Hope this helps.
    HTH-
    Jasmine.

  • Software update - networking error (Mac OS 10.4.11)

    Hi everyone,
    I've been having problems running software update on my 867 MHz Powerbook G4. Every time I try to run software update, I get the same message: "A networking error has occurred: timed out (-1001). Make sure you can connect to the Internet, then try again."
    I'm using Mac OS X 10.4.11.
    My network is running fine, and I've run Network Diagnostics several times fully through to confirm this.
    I've tried repairing the disk permissions through disk utility a few times, and nothing's changed.
    I tried copying three files from my Library / Preferences folder, along with my Caches folder (after reading that this could fix the problem), but still, software update doesn't work.
    I tried running the 10.4.11 combo update for PPC, rebooted in safe mode, and repaired my disk permissions again, but still, no luck.
    There's another problem that might be related: Safari can't load pages. Firefox 2.0.0.18 works fine, but Safari doesn't do anything. Also, closing the Safari window (Ctrl + W) doesn't work, quitting the program is the only way to make it go away.
    Thanks in advance for the help, it's much appreciated!

    Hi James, and a warm welcome to the forums!
    To expand a bit on Sig's great advice...
    "Try Disk Utility
    1. Insert the Mac OS X Install disc that came with your computer, then restart the computer while holding the C key.
    2. When your computer finishes starting up from the disc, choose Disk Utility from the Installer menu. (In Mac OS X 10.4 or later, you must select your language first.)
    *Important: Do not click Continue in the first screen of the Installer. If you do, you must restart from the disc again to access Disk Utility.*
    3. Click the First Aid tab.
    4. Click the disclosure triangle to the left of the hard drive icon to display the names of your hard disk volumes and partitions.
    5. Select your Mac OS X volume.
    6. Click Repair. Disk Utility checks and repairs the disk."
    http://docs.info.apple.com/article.html?artnum=106214
    Then Safe Boot, (holding Shift key down at bootup), run Disk Utility in Applications>Utilities, then highlight your drive, click on Repair Permissions, reboot when it completes.
    Also, how much free space do you have on your HDD?

  • Can't install iTunes upgrade due to network error

    I've never had a problem downloading & installing iTunes updates, but I've been trying for a week or two to update iTunes and I'm always getting the following error message:
    A networking error has occurred: timed out (-1001). Make sure you can connect to the Internet, then try again.
    There is NOTHING wrong with my Internet connection, and all my other Apple updates have installed successfully. I have NO idea how to try to fix this problem. Please help!!!

    I am getting this same message but only after the 38.5MB iTunes file has downloaded. Last week a forum named "can't download" also had several user posts with this same problem but I don't see it now. Thought I'd try upgrading again today but it still doesn't work. Does Apple read these posts?

  • Getting "Network Error"

    I have a summary report and I get the following message: "network Error" The client or server timed out waiting to receive data using TCP/IP.Check Network Connections. Increase the NetRetryCount and/or the NetDelay values in the ESSBASE.CFG file. Update this file on both client and server.Restart the client and try again. Network error [10054]: Cannot Receive Data.Do you have any ideas whta is going wrong? There is no ESSBASE.CFG file either on the server or on the client so I have already created them and set the NetRetrycount to 900 andNetDelay to 400 and I still get the same error. Critical situation. Many thanks

    I get the 10054 message almost daily when running Essbase on my laptop; it happens when I unplug my net card and a different IP address gets assigned to the laptop (Essbase doesn't like that!)BTW, restarting Essbase fixes it for me..Tim TowApplied OLAP, Inc

  • IO Error: Socket read timed out / IOP_iopinstance1_datasource" closed

    Hi ,
    Can somebody suggest what could be the probable cause of following errors showing up in IOP log file?
    ####<Aug 16, 2011 10:49:11 PM PDT> <Info> <Common> <sc-csttest> <IOPServer_iopinstance1> <weblogic.work.j2ee.J2EEWorkManager$WorkWithListener@357ac2f7> <<anonymous>> <> <0000J7MI9kZFk3vLsYw0yX1EIpFA00002K> <1313560151943> <BEA-000628> <Created "1" resources for pool "IOP_iopinstance1_datasource", out of which "1" are available and "0" are unavailable.>
    ####<Aug 16, 2011 10:49:12 PM PDT> <Info> <JDBC> <sc-csttest> <IOPServer_iopinstance1> <weblogic.work.j2ee.J2EEWorkManager$WorkWithListener@357ac2f7> <<anonymous>> <> <0000J7MI9kZFk3vLsYw0yX1EIpFA00002K> <1313560152146> <BEA-001128> <Connection for pool "IOP_iopinstance1_datasource" closed.>
    java.sql.SQLRecoverableException: IO Error: Socket read timed out
    Thanks
    Lokesh

    This particular error means your database is down and socket is timedout. Or the query takes so long that the reader timedout -- unlikely.
    Also, the general weblogic socket write errors, which you might see sometimes means that the client got disconnected before the server wrote results back. This is harmless

  • Why do I keep getting the message; Network error occurred?

    Whenever I try to send an email. The message in the outbox states the sending failed. When I click on that email, it simply states that, Network error, occurred.
    What is causing this network error?

    Hello,
    Thank for the reply. My zip code is: 19702.
    My browser is the latest Android. Completely stock. I can access the internet. I don't use chrome. 
    I get the message only when I try to send emails from my Verizon email account. I can sometimes receive email but not all the time. I cannot send emails at all once this happens. I can send and receive emails from other email accounts except Verizon (that is why I am using Hotmail).
    If I completely deleted my Verizon account, restart my phone, than add my account back on to the phone, it will work for a couple of emails than I will get the message; send fail. Network error occurred. 
    Sent from my Verizon Wireless 4G LTE smartphone

  • Can't software update, networking error, yet internet connection fine

    I am trying to use software update, but can't. I get this:
    "A networking error has occured: timed out (-1001). Make sure you can connect to the internet, then try again. Software Update can't check for updates because of a network problem."
    Yet network diagnostics show everything fine; mail works fine; network utility shows everything ok; wireless connection fine; TCP/IP looks normal; and browsers are fine -- here i am posting.
    WTH?!
    I know there are other threads about this, but the questions there are unanswered, even though the threads are marked answered.
    I tried the following:
    1. i backed up using Carbon Copy Cloner, then wiped my HD and copied back. That was ok, but still couldn't use software update.
    2. i archived/installed 10.4, restarted.Some prefs gone but basically ok, couldn't use software update.
    3. downloaded last combo update 10.4.7, and last security update. Quit everything, repaired perms, installed combo update, restarted. Installed security update, restarted.
    4. i reset PRAM.
    5. i checked the disk using Disk Utility. It's fine.
    6. I made a new user account to test. Logged in there, tried software update, same result.
    And i still can't use software update.
    Someone in another thread wrote that this seems to be in UK and Netherlands. Possible?
    Any suggestions anybody?
    thanks, P
    powerbook g4, 1ghz, 512 mb ram   Mac OS X (10.4.7)  

    sorry, i forgot that: Yes, i deleted:
    /Library/Preferences/com.apple.SoftwareUpdate.plist
    [home]/Library/Preferences/com.apple.SoftwareUpdate.plist
    [home]/Library/Preferences/ByHost/com.apple.SoftwareUpdate.plist
    This last i am not sure of the exact name, i saw it before, deleted it, but it hasn't been regenerated.
    there is also:
    [home]/Library/Caches/Software Update/
    which has nothing in it;
    and
    [home]/Library/Preferences/com.apple.SoftwareUpdate/
    which has a lot of numbered folders and cache files with names like
    '1321878279-2428557571.cache'
    Should i try deleting those?
    How do i find out the server name for Software Update btw?
    Perhaps i should try plugging that into the SoftwareUpdate.plist?
    thanks, P
    powerbook g4, 1ghz, 512 mb ram Mac OS X (10.4.7)

  • HT4972 Restoring with itunes says network error

    I have iphone 4 32 GB ios 6.1.3. I have some bug issues in my phone.
    I tried to Restore with itunes, but after almost 4 hrs when the downloading was nearing complete... It says 'Network error'
    I tried this for 3-4 times..
    Please guide...

    Turn off all anti-virus software & firewalls. Try again.

Maybe you are looking for

  • Add Minutes to a Timestamp column

    Hello there, I need to know how to add minutes to a timestamp column in APEX. I was looking for an answer on the internet but the DATEADD function doesn't work in APEX. Any ideas? Ruben

  • Add_tree_data - tree node label cannot be null

    I have a hierarchical tree displayed and when the user expands a node I'm calling add_tree_data using a record group to add items to the expanded node. This works for the first node I expand, if I try to expand another node I get frm-47337 Tree node

  • Master data Load - Strategy

    Hi All, I would like to know the better master data strategy. When using 3.x master data load strategy I can load directly into the info object without going thru additional DTP process. Is there any specific advantages of doing this, besides that it

  • Blu-ray archiving

    Roxio's website, maker of Toast, states that blu-ray discs will hold 50gigs of data. is anyone out there using blu-ray on a mac for archiving purposes and if so, how much video are you getting on a single sided 25gig or a 50gig? I have a large librar

  • Error using tag  cfhtmlhead

    I have a page referring to itself. The code is trying to go to an anchor on the page. Please check the syntax in my code which uses the cfhtmlhead tag. Note it has two pound symbols in a row, like this ## <cfif structKeyExists(session.currentperson,