Nexus monitoring, device recource metrics

Hello
I'm looking for Nagios/Nexus Plugins and lesson learned is, that there seams to be currently (2011/10/20) nothing at all.
So I want to start with this and want to ask the experts about the basics of Nexus monitoring.
What is the best practice to monitor Nexus device recource metrics? NetConfig, SNMP, SSH with preshared key?
For Netconfig are there any documentation how to can use it with Perl?
If SNMP should be still the best, are this OIDs known or what should be the best method to get them out?
Are there SNMPv3 issues e.g. with views?
How to find out the Nexus OID's for its IOS-equivalents, e.g.
"Voltage" => ".1.3.6.1.4.1.9.9.13.1.2",
"Temperature" => ".1.3.6.1.4.1.9.9.13.1.3",
"Fan" => ".1.3.6.1.4.1.9.9.13.1.4",
"PSU" => ".1.3.6.1.4.1.9.9.13.1.5"
ModuleState ?
How to find out OIDs for special CLI commands, e.g. traffic class violations:
sh policy-map interface control-plane | egrep "class-map|violated"
    class-map copp-system-class-normal (match-any)
        violated 5394687638 bytes; action: drop
If Netconfig is to complicated and finding Nexus SNMP-OIDs is an unresolveable neightmare, can SSH with preshared key could be an oportunity for permanent monitoring?
many thx in advance for your hints and ideas,
Steffen

Though Nexus 7004 is supported from LMS 4.2.2 onwards, but it is in a restricted support :
The following features are supported:
Fault Management
Network Topology Layer 2 Services
The following features are not supported:
Inventory Collection , User Tracking, VLAN Management, VRF Lite, LANE Management
Configuration Deploy Protocols: HTTPS, SCP, RCP, TELNET, TFTP, SSH
Configuration Fetch Protocols: HTTPS, SCP, RCP, TELNET, TFTP, SSH
Software Distribution by: Advanced flow, Image, Remote Staging
Software Repository Synchronization
CiscoView
Software Image Types for Distribution: System Software, Bootloader
Software Images Import from: Cisco.com, Device, File System, Network, URL
Upgrade Analysis from: Cisco.com, Repository
Software Image Import Connection Protocols: SNMP
Software Image Import Transfer Protocols: TFTP,  TELNET
Software Image Distribution Transfer Protocols: TFTP, TELNET
Software Image Distribution Connection Protocols: SNMP
If this is not working, it is only that the essential device package seems to be missing. please do the following :
1. Download all device packages available for LMS server :
     Step 1: Open command prompt on server.
     Step 2: Run following cli command :
psucli -p rme,cmf,dfm,cvw,upm,cm -download -dst C:\test_download -all
**Created test_download dir or name some existing.
     Step 2: Check the downloaded files, if they are in diffrent folders inside download dir, copy all of them to a common folder and run this command :
psucli -p rme,cmf,dfm,cvw,upm,cm -install -src D:\test_download -all
**use directory you downloaded packages to
     Step 4: Check the device if it shows nexus 7004 information or not.
Share results.
-Thanks
Vinod
**Rating Encourages contributors, and its really free. **

Similar Messages

  • Using LMS 3.2 can it possible to monitor device Utilization

    Hi,
    Running LMS 3.2. Can we able to see the utilization reports related CPU,memory,link,interface etc ??
    Help me out!!!
    Regards,
    Krishna

    Hi,
    If you have HUM installed along with LMS 3.2, you will be able to monitor Device Utilization too. By default HUM comes as an add on for 90 days of evaluation period with the LMS 3.2 bundle setup.
    Thanks,
    Gaganjeet

  • LMS 4.0: Fault Monitoring Device Administration stuck in learning

    Hello Members,
    i have a problem with Fault Monitoring Device Administration. i have two devices which stuck in learning mode for almost forever. When the job is done the devices report an error SNMP timeout. I run a credential verfication job and the credentials for the devices are correct.
    any ideas?
    regards
    alex

    Assuming these are the only four devices using SNMPv3 in LMS, then the engineID is a non-issue.  However, if any other device has the same engineID as those two non-working devices, the problem could still be a duped engineID.  Debugging with logs is fairly complex.  The easiest way to identify the problem is to use a sniffer.  Start a sniffer trace filtering on all traffic to one of the failing devices.  Then, rediscover the device in Fault Monitoring under Admin > Collection Settings > Fault > Fault Monitoring Device Administration.  When it goes to a Questioned state, look at the sniffer trace.
    If you see SNMP report packets indicating an error of notInWindow, that points to the duplicate engineID problem.  ICMP packets without responses points to problems with ping.

  • Cisco Nexus 5548 device

    Hi,
    Can you please let me know how to get (command) Manufacture date for Cisco Nexus 5548 device.
    Appreciate your support.
    Thanks,
    Brahma

    Hi Brahma,
    I dont believe there is a command which would give you the Manufacture date directly, however there is an old theory which speaks about decoding the date of manufacture from the serial number.
    Excerpt is as captured below:-
    The date code is built into the serial number. The format is LLLYYWWSSSS, where:
    LLL is the location at which the unit was built.
    YY is the year that the unit was built (1997=01, 1998=02, 1999=03, 2000=04).
    WW is the work week of the year that the unit was built.
    SSSS is the serial number.
    Else the account rep would be able to give more details by backtracking the serial number to the inventory.
    HTH,
    S@G@R

  • UCCX 10.5 HA, Silent Monitoring, no devices under CDA VoIP Monitoring Device

    Hi
    I'm configuring Silent Monitoring, but in UCCX CDA under Settings: Services Configuration > Multiline, Monitoring & Recording > VoIP Monitoring Device, there are no devices.
    Note: I have CAD agents setup with IP Phone working properly. UCCX is "IN SERVICE", Cisco Desktop VoIP Monitor Service "IN SERVICE"
    UCCX 10.5.1.10000-24
    Let me know if someone had the same issue.
    Regards
    Carlito

    Hi Carlito,
    you need to agregate IP Phone that you want to monitor  to RmCm User (Application user), in "Device Information/Controlled devices", and save.
    Let me know if this information could help you.
    Regards,
    Caosfox

  • RME 4.3.1 & Nexus 7000 device package

    I am have 27 devices that RME reports as "Out-of-Sync", among those some are Nexus 7K devices, with the sysObjectId .1.3.6.1.4.1.9.12.3.1.3.612, which according to the "Supported Device Table for LMS 3.2" is supported in RME 4.3.1.
    Searching for device package with that sysObjectId I get no result in Common Services. However, when performing a "Device Update" with my CCO account, Ciscoworks tells me that "All the available package(s) at source location are already installed."
    What do I have to do to get that device package?

    Hi,
        To check / download the latest RME Device Package for Nexus 7k support, please do the following :
    1. Go to Common Services -> Software Centre -> Device Update and click on the hyperlink for 'CiscoWorls Common Services'
    * You should see 2 packages listed  - Device Data and MDF.
    * The latest versions of these are 1.10 and 1.48 respectively.
    * If you don't have the lateset versions installed, please run an update to install these.
    2. Once you have the most up to date packages for Common Services installed, go to Common Services -> Software Centre -> Device Update and click on the number in the 'Device Type Count' collumn for Resource Manager Essentials.  Filter the list of devices by Package Name = Nexus.
    * Do you see sysObjectId .1.3.6.1.4.1.9.12.3.1.3.612 displayed ?
    * What version of the Nexus device package do you have installed ? (The latest version is 2.5)
    3. Even if you have the latest Nexus package installed, run a device update for RME so that you loaded the latest versions of all packages (I see there were some new updates for shared packages eg LibCommon as recent as 21st January 2011.
        In terms of the devices being reported as 'Out-of-sync' , this means that RME has detected that the running configuration and the startup configuration on the device are different. This could be because RME doesn't have the most recent copy of either config or it is a real situation of the startup and running config being out of sync on the device.  If you go to the Out-of-Sync Summary page, select the Nexus 7k's and click on 'Sync on Device' RME will run a job to login to the devices and execute a copy run start.
    * If your Nexus 7k's are still reported as 'Out-of-Sync' after the job completes then we'll need to investigate further.
    Regards
    Derek Clothier

  • Critical Alarm for Nexus 7010 device

    Hi Team,
    We are getting Critical Alarm for the Data center device Nexus 7010 continuously from 28-Oct.
    error (device hde1) in start_transaction: Journal has aborted - kernel
    2012 Oct 29 10:00:18.227 DC-Core-Switch2 29 10:00:18 %KERN-2-SYSTEM_MSG: EXT3-fs
    error (device hde1) in start_transaction: Journal has aborted - kernel
    2012 Oct 29 10:28:37.497 DC-Core-Switch2 29 10:28:37 %KERN-2-SYSTEM_MSG: EXT3-fs
    error (device hde1) in start_transaction: Journal has aborted - kernel
    2012 Oct 29 10:28:42.398 DC-Core-Switch2 29 10:28:42 %KERN-2-SYSTEM_MSG: EXT3-fs
    Also attaching the complete logs collected for this device and suggest if there is any Hardware related issue or some Software related issue.
    Regards,
    Ashutosh

    Hello
    hde1 is the logflash device. Looks like there were IO errors and the kernel mounted the fs read-only. You can try to reload the device and if logflash will come back up fine after the reload, its a transient issue; if the issue comes back, the logflash device most likely is damaged bad and needs to be replaced. You will need to open a service request with TAC to get it replaced.
    HTH,
    Alex

  • LMS 4.2 Fault Monitor - Device Name and Frequency of Events

    Hi all,
    I've just installed LMS 4.2, like it a lot so far.  But I'm running into a few problems, and I'm hoping someone out here has a suggestion. 
    In the Fault Monitor, the Device Name column shows the device's IP address rather than the host name.  We need for it to show the host name, for ease of troubleshooting; most folks don't have the IP addresses memorized.    Likewise, when an email is sent out for an event, the managed device field also shows up as the device's IP address.
    The devices were all discovered with their IP addresses rather than a host name...should LMS have automatically found their host names?  Regardless, I manually updated all of the device's host names, yet they still display as an IP address in the fault monitor. 
    Also, it appears I need to figure out some way to throttle alerts.  One particular device will report an event (ie a temperature out of range) dozens of times in a polling period...several per second, even though it's the same alert.  Any suggestions on where I can throttle this?  My inbox is exploding.                  
    If anyone has any ideas, I would appreciate it!
    Jen

    I am having the IP vs. device name issue as well. The funny thing is if you hover over the IP of the device in Fault Monitor, you can see the device name listed. I was on a conference call with Cisco recently and pointed this out. One of the reps said the faults and alerts showing IP address issue should be fixed in version 4.2.3, but I don't know if he was basing this on first-hand knowledge or was just assuming. Does anyone know if this is the case?
    As for throttling alerts. I had a false positive alert from a device that I put in a custom fault group and changed the threshold on to keep them from firing. You probably have already resolved this issue, but I didn't see a resolution listed here. You would have to determine if raising a threshold for a device is adequate for your situation.
    Thank you,
    Mark

  • Network Monitoring Device

    Hello,
    I have added some device which were not supported in SCOM into network monitoring with ICMP ONLY for availability reporting porpuse. The devices got discovered and showing healthy in Network Monitoring Pane. However, when I open network node dashboard, the
    Average Availability Dashboard is RED and get the below error.
    I am using SCOM 2012 R2, with dedicated Resource pool for Network monitoring.
    Please provide the following information to the support engineer if you have to contact Microsoft Help and Support :
    Microsoft.EnterpriseManagement.Presentation.DataAccess.DataProviderException: An error occurred executing the command: [Microsoft.EnterpriseManagement.Presentation.DataProviders.Library!NetworkDashboardProvider/GetManagedEntityAvailabilityPercentage] in
    provider: [Microsoft.EnterpriseManagement.Presentation.DataProviders.NetworkDashboardProvider, Microsoft.EnterpriseManagement.Presentation.DataProviders.Library, Version=7.0.5000.0, Culture=neutral, PublicKeyToken=31bf3856ad364e35]. : Unable to execute stored
    procedure needed for dashboard.  If you just installed Operations Manager Reporting Server, please wait a while and try again.  This can also occur if the Operations Manager Reporting Server SQL Server is not started or inaccessible. ---> Microsoft.EnterpriseManagement.Presentation.DataProviders.DataWarehouseException:
    Unable to execute stored procedure needed for dashboard.  If you just installed Operations Manager Reporting Server, please wait a while and try again.  This can also occur if the Operations Manager Reporting Server SQL Server is not started or inaccessible.
    ---> Microsoft.EnterpriseManagement.Common.UnknownDatabaseException: Sql execution failed. Error 777971002, Level 16, State 1, Procedure Microsoft_SystemCenter_Visualization_Library_GetManagedEntityAvailability, Line 43, Message: Sql execution failed. Error
    0, Level 0, State 0, Procedure SDK.GetManagedEntityAvailability, Line 0, Message: Non existent managed entity
       at Microsoft.EnterpriseManagement.Common.Internal.ServiceProxy.HandleFault(String methodName, Message message)
       at Microsoft.EnterpriseManagement.Common.Internal.MonitoringDataWarehouseServiceProxy.GetDataWarehouseStoredProcedureResult(String SpName, StoredProcedureParameterCollection param, IEnumerable`1 columnFilter, Int32 timeout)
       at Microsoft.EnterpriseManagement.Warehouse.DataWarehouse.GetDataWarehouseData(String storedProcedureName, StoredProcedureParameterCollection param, IEnumerable`1 columnFilter, Int32 timeout)
       at Microsoft.EnterpriseManagement.Presentation.DataProviders.NetworkDashboardProvider.GetManagedEntityAvailabilityPercentage(DateTime startDateTime, DateTime endDateTime, Guid managedEntityId, Int32[] goodStates)
       --- End of inner exception stack trace ---
       at Microsoft.EnterpriseManagement.Presentation.DataProviders.NetworkDashboardProvider.GetManagedEntityAvailabilityPercentage(DateTime startDateTime, DateTime endDateTime, Guid managedEntityId, Int32[] goodStates)
       --- End of inner exception stack trace ---
       at Microsoft.EnterpriseManagement.Presentation.DataAccess.DataProviderCommandMethod.Invoke(CoreDataGateway gateWay, DataCommand command)
       at Microsoft.EnterpriseManagement.Presentation.DataAccess.CoreDataGateway.ExecuteScalarInternal[TResult](DataCommand command)
       at Microsoft.EnterpriseManagement.Presentation.DataAccess.CoreDataGateway.<ExecuteScalarAsync>b__2[TResult](<>f__AnonymousType0`1 data)
    Any help is appreciated.
    Thanks,
    Binoy Das

    The below step solved the problem. It might help someone.
    Assessment :
    Log Name:      Operations Manager
    Source:        Health Service Modules
    Date:          7/24/2014 2:38:04 PM
    Event ID:      31553
    Task Category: Data Warehouse
    Level:         Error
    Keywords:      Classic
    User:          N/A
    Computer:      abc.domain.com
    Description:
    Data was written to the Data Warehouse staging area but processing failed on one of the subsequent operations.
    Exception 'SqlException': Sql execution failed. Error 2627, Level 14, State 1, Procedure ManagedEntityChange, Line 368, Message: Violation of UNIQUE KEY constraint 'UN_ManagedEntityProperty_ManagedEntityRowIdFromDAteTime'. Cannot insert duplicate key in object
    'dbo.ManagedEntityProperty'. The duplicate key value is (28420, May 15 2014  1:34AM).
    One or more workflows were affected by this. 
    Workflow name: Microsoft.SystemCenter.DataWarehouse.Synchronization.ManagedEntity
    Instance name: Data Warehouse Synchronization Service
    Instance ID: {4F977FCC-C642-3A1B-849C-B74CD07B4D51}
    Management group: XXXX
    Workflow : : Microsoft.SystemCenter.DataWarehouse.Synchronization.ManagedEntity , not able to insert data to the records already available in table Managedentityproperty.
    Next Action:
    •         Take the Full backup of Operations Manager Database and Data Warehouse
    •         After backup completed run  the below queries to back up the ME stage table and then remove the duplicate entries
    select * into ManagedEntityStageDuplicates from ManagedEntityStage
    delete mes
    from ManagedEntityStage mes
    inner join ManagedEntity me on mes.ManagedEntityGuid = me.ManagedEntityGuid
    inner join ManagedEntityProperty mep on me.ManagedEntityRowId = mep.ManagedEntityRowId
    where mep.FromDateTime = mes.ChangeDateTime

  • How to exclude the monitoring (device avaibility) on an interface vlan?

    Hello All,
    How can i exclude the monitoring on an "intervace vlan"
    My switch 3750X have many interface vlan , LMS 4.2.2 discover the device and have an automatic poller that test the reachability on the IP for these interface vlan.
    And i have many Critical alarmes when the interface vlan is down, because no end host are in this vlan
    (Operationaly Down, Unresponsive).
    Thank you.
    Alain Pernelle.

    Hello pkr_legend,
    Take a look at these symptoms and see if the troubleshooting steps help to resolve your issues.  Please let me know.
    Good luck!
    ↙-----------How do I give Kudos?| How do I mark a post as Solved? ----------------↓

  • Voice Monitoring Devices in UCCX 8.51 SU1

    Why do the devices not show up in the Desktop Admin web page under Voice Montoring Devices? I get the following error when I try to monitor.
    Supervisor has failed to start voice monitor on the device :2337
    It is not the NIC card because it happens across the board

    Are agents using extension mobility? There are multiple defects opened for 8.5.1 monintoring issues.
    CSCtq46866
    CSCtq55066

  • How to monitor gbic SFPs metrics using SNMP?

    i have
    Vendor Name           :   CISCO-FINISAR
    Vendor Part Number    :   FTRJ1319P1BTL-C
    Vendor Revision       :   0x42 0x20 0x20 0x20
    and when i try to get info from telnet i get normal information
    #sho interfaces transceiver
    If device is externally calibrated, only calibrated values are printed.
    ++ : high alarm, +  : high warning, -  : low warning, -- : low alarm.
    NA or N/A: not applicable, Tx: transmit, Rx: receive.
    mA: milliamperes, dBm: decibels (milliwatts).
                                               Optical   Optical
               Temperature  Voltage  Current   Tx Power  Rx Power
    Port       (Celsius)    (Volts)  (mA)      (dBm)     (dBm)
    Gi0/26       52.5       3.25      26.9      -5.7     -13.8
    but i couldnot get from snmp can someone tell me if is some configure in device or  oid .

    i have
    Vendor Name           :   CISCO-FINISAR
    Vendor Part Number    :   FTRJ1319P1BTL-C
    Vendor Revision       :   0x42 0x20 0x20 0x20
    and when i try to get info from telnet i get normal information
    #sho interfaces transceiver
    If device is externally calibrated, only calibrated values are printed.
    ++ : high alarm, +  : high warning, -  : low warning, -- : low alarm.
    NA or N/A: not applicable, Tx: transmit, Rx: receive.
    mA: milliamperes, dBm: decibels (milliwatts).
                                               Optical   Optical
               Temperature  Voltage  Current   Tx Power  Rx Power
    Port       (Celsius)    (Volts)  (mA)      (dBm)     (dBm)
    Gi0/26       52.5       3.25      26.9      -5.7     -13.8
    but i couldnot get from snmp can someone tell me if is some configure in device or  oid .

  • Cisco monitoring devices

    I have a question how can you monitor on a Cisco router and switches, and receives a message?

    Hi ,
    You need a Monitoring software  E.g Cisco works .
    You can download an Evaluation software from the below link which will be Expired in 90 days :
    https://cisco.mediuscorp.com/market/networkers/homeWork.se.work
    Thanks--
    Afroj
    If this post answers your question, please click the "Correct Answer" button"

  • Aaa New format configuation on IOS and Nexus-OS based devices ?

    Dear all,
    I have been working on an assignment to get our TACACs servers  standardized and to change the old format  aaa configs to the new  standard before the old format gets deprecated.
    I have many multiple IOS based model devices such as 2350, 2821,  3650,   Firewalls, Nexus based 3048s 3064s  and 7010s
    However,   I have tried the new format on both the IOS based 2350s and also on  the Nexus based 3048s which has error on both cases
    our plan is to move to the new style of aaa configuration and at  least to have one standard format configuration for IOS based devices  and one other standard format for Nexus based devices.
    •Our tacacs appliances are crashing on AD authentication on a fairly  regular basis. And I was wondering as to where to get resource on  Cisco.com to see if we are on the latest version. Can you point me  resource where I can find the latest version so that I will be able to  compare it with what we have
    Also if you have a forum recommendation for me to get help on this and other related staff that will be a huge help.
    probably we might need to upgrade our IOS for example the below new  aaa config format didn’t work?  when I tried it on 2350 based on  flash:/c2350-lanlite-mz.122-46.EY/c2350-lanlite-mz.122-46 version any  suggestion here?
    I have attached the sample config I have been trying to use-- If you have a better configuration suggestion let me know? Thanks a million for the help!
    Abe
    With Regards,
    Abe

    Yes, the focus with ML is certainly on trying to get people who have iOS devices to switch to using Apple computers.
    For long-time devotees of OS X like us, there's not much in it. Snow Leopard was still a far more versatile and more widely compatible OS than either 10.7 or 10.8. If you're on 10.6.8. I would think twice about upgrading.
    However, I think if you're on 10.7 already, it's worth upgrading to 10.8, simply because ML seems to be more stable and more refined. They have fixed some of the annoying things in Lion (like you can now put Devices back to the top of the Finder sidebar, Resume is turned off by default, 'Save As' has been resurrected, Launchpad actually has a filter bar etc etc.). Some of the apps are better too - some nice new features in Preview for editing and Safari has an all-in-one address/search bar).
    More features are advertised explained here: http://www.apple.com/osx/whats-new/features.html

  • Metrics to monitor Alert Log

    Hi,
    I am trying to make modification in metric for monitoring alertlog.
    When I try to add a new line,it's asking for field "Time/Line Number",any one know what should be the value for that?
    Description on that page --> "The table lists all Time/Line Number objects monitored for this metric. You can specify different threshold settings for each Time/Line Number object." doesn''t make much sense to me.
    I gave a dummy value 50,but it doesn't seem to work..
    Any help is highly appreciated... thanks...

    For monitoring <11g database note 976982.1 may be of use to you: https://support.oracle.com/CSP/main/article?cmd=show&type=NOT&doctype=BULLETIN&id=976982.1;
    For monitoring 11g db's see note 949858.1 (Monitoring 11g Database Alert Log Errors in Enterprise Manager)
    I your case you may want to consider to create a UDM, see Monitor Non Critical 11g Database Alert Log Errors Using a SQL UDM [ID 961682.1]
    Eric