NI cRIO-9073 connection (software error)

Hi,
I tried to connect to the cRIO using MAX. But there is software error (as shown in picture MAX). What shoud I do?
Regards
Solved!
Go to Solution.
Attachments:
MAX.jpg ‏115 KB
Internet protocol version.jpg ‏70 KB

Dear Sljukaa,
You are working with the cRIO. So the modules list will may not come in MAX. To identify the problem create a FPGA application and descover the c Series modules in LabVIEW. You will get the module list in FPGA parent in Tree. If still you feel some issue to detect the module Open your LabVIEW INI file and copy past "cRIO_FavoriteBrand=generic" line.
Thanks and Regards
Himanshu Goyal | LabVIEW Engineer- Power System Automation
Values that steer us ahead: Passion | Innovation | Ambition | Diligence | Teamwork
It Only gets BETTER!!!

Similar Messages

  • Not able to create OUT file with "nidll_vxworks" in Matlab for use with the LabVIEW SIT 2010 and a cRio 9073, sh.exe error

    I am trying to compile an OUT file for my Simulink model using "nidll_vxworks" and run it using the Simulation Interface Toolkit for a cRIO 9073 . I am able to compile the DLL file using "nidll" and succesfully run the simulation using my PC as the host.
    I already downloaded the "gccdist" and "vxworks61gccdist" folders and copied them to "c:" When I build the model in Sumulink I get the following error at the end of the process (at the same time windows tells me that "sh.exe" has stopped working). If it matters I am running Windows 7 64bits, but using Matlab 2009b 32bits and LabView 2010 32 bits. ANY HELP WILL BE APPRECIATED. "QofV" is the name of my Simulink model and I changed to "XXX" parts of the file path.
    ### Linking ...
    rm -f "QofV.out" ctdt.c;nmppc QofV.o QofV_data.o rtGetInf.o rtGetNaN.o rt_logging.o rt_look.o rt_look1d.o rt_nonfinite.o  nidll_main.o rt_sim.o ode8.o    | tclsh c:/gccdist/WindRiver/vxworks-6.3/host/resource/hutils/tcl/munch.tcl -c ppc > ctdt.c 
    abnormal program termination 
    C:\Users\XXX\AppData\Local\Temp\make426012.sh: fork failed: no child processes [1]
    make: *** [QofV.out] Error 1 
    ### Real-Time Workshop build procedure for model: 'QofV' aborted due to an error.
    >> 
    ### Linking ...rm -f "QofV.out" ctdt.c;nmppc QofV.o QofV_data.o rtGetInf.o rtGetNaN.o rt_logging.o rt_look.o rt_look1d.o rt_nonfinite.o  nidll_main.o rt_sim.o ode8.o    | tclsh c:/gccdist/WindRiver/vxworks-6.3/host/resource/hutils/tcl/munch.tcl -c ppc > ctdt.c  
    abnormal program termination 
    C:\Users\XXX\AppData\Local\Temp\make426012.sh: fork failed: no child processes [1]make: *** [QofV.out] Error 1 ### Real-Time Workshop build procedure for model: 'QofV' aborted due to an error.>>
    ### Linking ...rm -f "QofV.out" ctdt.c;nmppc QofV.o QofV_data.o rtGetInf.o rtGetNaN.o rt_logging.o rt_look.o rt_look1d.o rt_nonfinite.o  nidll_main.o rt_sim.o ode8.o    | tclsh c:/gccdist/WindRiver/vxworks-6.3/host/resource/hutils/tcl/munch.tcl -c ppc > ctdt.c  abnormal program termination C:\Users\XXX\AppData\Local\Temp\make426012.sh: fork failed: no child processes [1]make: *** [QofV.out] Error 1 ### Real-Time Workshop build procedure for model: 'QofV' aborted due to an error.>> 
    Solved!
    Go to Solution.

    Hello jarcTec,
    I am not sure right now if you can do it, but this tutorial might help, also everything was made in Winddows 7 in this one.
    http://zone.ni.com/devzone/cda/tut/p/id/11654
    Take a quick look and let me know if it works!!!
    Luis Fernando
    National Instruments Cono Sur
    Ingeniería de Campo y Consultoría
    http://chile.ni.com/

  • Error when running simulation with SIT 2010 on a cRIO 9073, what do I need to install on the cRio?

    Hi.
    I am trying to run a simulink model on a cRio 9073 using SIT 2010. I succesfully created the FPGA vi and the lvbit file in order to map input/outputs to the model. I also created the DLL and OUT for the model.
    When I run the interface VI on my computer, everything seems OK, until I get the following error and I am not able to run the simulation. I found a similar post earlier that suggests that I need to install the shared variable engine or the Simulation Interface Toolkit on my cRio. I tried to do both using MAX but could not find neither of the suggested installations.
    Thanks for the help!
    Items.viNI_SIT_driversupportVIs.lvlibIT Probe Model Items.vi loaded with errors on the target and was closed.
    LabVIEW:  Failed to load shared library SITs.*robeSignals:C. Ensure that the library is present on the RT target. Use MAX to install NI software or FTP to transfer custom libraries to the RT target.
    Items.viNI_SIT_driversupportVIs.lvlibIT Probe Model Items.vi loaded with errors on the target and was closed.LabVIEW:  Failed to load shared library SITs.*robeSignals:C. Ensure that the library is present on the RT target. Use MAX to install NI software or FTP to transfer custom libraries to the RT target.

    Hola jarcTec;
    Este tipo de error suena suele ocurrir cuando no se tienen las librerías apropiadas instaladas en el cRIO. Te recomendaría que abrieras MAX, debajo de la pestaña de Remote Systems selecciones tu dispositivo>> software, click derecho e instalar software. Aquí debes asegurarte que las librerías que te faltan estén instaladas en el cRIO. En Custom Installation selecciona SIT como opción para instalar en el cRIO tal y como se muestra en las imagenes.
    Espero esta información te sea de utilidad
    Exito en tu aplicación
    Marisol

  • Error While Reading a file Dynamicall​y in CRIO - 9073

    Hello all,
              I am using CRIO - 9073, here i transferred a file (With size of 5mb) through FTP from my PC..... and then i am trying to read it Dynamically, but while i am reading this file and updating, my CRIO going to stop mode...... So i can't workout more... Give a fine reply all...
    Regards
    Pandithan.

    What code for path building do you have running on the CRIO?
    Ton
    Free Code Capture Tool! Version 2.1.3 with comments, web-upload, back-save and snippets!
    Nederlandse LabVIEW user groep www.lvug.nl
    My LabVIEW Ideas
    LabVIEW, programming like it should be!

  • SbRIO (cRIO) reboots into safe mode (software error)

    Hi there,
    I've used the sbRIO-9612 for year on the project, recently it sometimes reboots into safe mode. In MAX I may find the status of the sbRIO is "Safe Mode with software error". Can anyone tell me, how can I find out where is the problem. I have the error log as attachment.
    Regards,
    Wilbur
    Solved!
    Go to Solution.
    Attachments:
    lvrt_err_log.txt ‏51 KB

    Hi,
    I read again the log file. There're something that should help:
    Exception code: 0x00000700
    Thread ID: 0x02E270B8 Thread name: niserial
    Thread stack base: 0x02E270B8 stack size: 32768
    Call Stack:
    0x1de9170+0xe93cc: _dtors () in module niserial.out
    0x1ddd83c+0xdda98: _dtors () in module niserial.out
    0x1dc840c+0xc8668: _dtors () in module niserial.out
    0x1df3a34+0xf3c90: _dtors () in module niserial.out
    0x1db2154+0xb23b0: _dtors () in module niserial.out
    0x1dc6a2c+0xc6c88: _dtors () in module niserial.out
    0x1dc68a0+0xc6afc: _dtors () in module niserial.out
    0x1dc67b0+0xc6a0c: _dtors () in module niserial.out
    0x3dbc80+0x8: Virtual function table for __cxxabiv1::__si_class_type_info () in module 0x0

  • Why Do I Receive Internal Software Error(s): Terminal Index Out of Bounds. Error code -61350,When Compiling my FPGA VI for an cRIO-9118 using NI 9223 ?

    I am receiving the following error (in a pop-up window) when compiling my VI FPGA code in chassis NI 9118 using NI 9223 module.  This error occur while compiling process (generating intermediate files , stage 7 of 7). how do I resolve this error ?
    thank you
    additional information :
    Original error message: 
    Errors : 
    Internal Software Error(s): Terminal Index Out of Bounds.
    Error code: -61350
    Details : 
    A terminal with this index does not exist on this block diagram node.
    NiFpgaHandleCallbackError.vi<APPEND>
    <b>Complete call chain:</b>
    NiFpgaHandleCallbackError.vi
    niFpgaNodeInformation.lvclass:Get Const Variant.vi
    DfirModGen.lvclass:GetConstant.vi
    niLvFpgaMungerBrainwashIONodeCommon_Dfir.vi
    niLvFpgaMungerBrainwashSingleIOGrowableMethod_DFIR.vi
    nirviEIOMethodImplementation_SpecifyDFIR.vi
    nirviEIOMethodImplementation_SpecifyDFIR.vi.ProxyCaller
    Solved!
    Go to Solution.

    Hi tesa,
    This is a bug which was fixed in LabVIEW 2012 SP1. The CAR number created for this bug is 332811 and as you can see in this link, it is already in the bug fixes list.
    Carmen C.

  • How to use SEA GSM Module on different slot of the cRIO 9073

    Hello to All,
    I have a SEA GSM+ Module on my cRIO 9073 at slot 7. I run the example program included in the resource CD as well as compiling the FPGA driver on my target but still don't work. Power supply is connected on the module. I don't know what I am missing. I followed strictly below steps as indicated in the read me text file but still nothing works. Please help.
    How to switch the FPGA Target on LabVIEW
    Complete the steps only if you use FPGA target other than 9104.
    1.  Add your new Compact RIO Target to the project
    1.  Add the new FPGA target below the cRIO-RT Target.
    3.  Drag the Gxxx folder from the original FPGA target and drop it into the new FPGA target. Make sure, that the module with its IOs, the FIFOs and the FPGA VI are integrated
    4.  Recompile the main VI - FPGA_App.vi, which is located in the Gxxx folder. A new bit file is created (.lvbit)
    5.  Open the Gxxx_Open.vi and select the just created bit file within the 'Open FPGA VI Reference.vi'.
    6.  Bind to TypeDef using ..Shared/Shared_TypeDefs.llb/Gxxx_FPGA_RefNum.ctl.
    7.  Close all VIs and do a "Save All, this project"
    Thanks in Advance,
    Joey

    Hello Jeff,
    The module is not working in any slot. Yes, I am using the sample code provided with the module name "Gxxx.lvproj". And also the FPGA is successfully compiled. Please see attached file for the error I received by the module.
    I already see this error in this forum and it was answered by powering the module by the external power supply. I already powered it. but still got an error.
    For the clarification, I am not using the  "SEA cRIO-Combo plus" module in the project rather I am using "SEA cRIO-GSM plus". I also attached the sren shotof the manual. I don't see any Toolkit Software manual in the resource CD and on the SEA website.
    Best Regards,
    Joey
    Attachments:
    GSM error.JPG ‏34 KB
    manual.JPG ‏91 KB

  • NI CRIO 9073 doubt regarding compatibility

    Hello,
                 I have installed 2011 version of labview in one PC and on another PC I have 9.0 version. More, I would like to write a simple program in MODBUS RTU in such a way that can communicate with pressure sensor(Keller) that is already connected to a NI-CRIO 9073(version 10.0) module.
    Problems have been faced..
    1) When try to connect remotely to my CRIO 9073 from each PC, I gives an error message that the versions are not compatible. I had installed version of 2011 labview but still the CRIO 9073 is not connected to new verstion. Is there any special drivers for this.
    2) I don't have modbus Vi options in my 2011 version. I downloaded MODBUS zip file from ni website but I am not sure how can I import that options into my labview functions pallet.
    Thank you.

    Hi Peter,
    "but those two systems are giving compatible error."
    That's what I summarized in my previous post. And I gave a hint on how to solve that.
    "I am new to measurement and automation in labview."
    That doesn't imply you don't need to read the documentation. You have a document coming with your cRIO that describes installation routines and you should be able to contact NI in case of bigger problems...
    Best regards,
    GerdW
    CLAD, using 2009SP1 + LV2011SP1 + LV2014SP1 on WinXP+Win7+cRIO
    Kudos are welcome

  • How can I diagnose a Labview RT program crash on cRIO 9073?

    I have 2 cRIO 9073 purchased about 1 year apart.  Both are running the same realtime application.  The first cRIO runs fine.  The 2nd cRIO crashes intermittently while executing 1 particular VI that contains 2 timed loops running in parallel (1 collecting data and the other controlling machine movement).  When it crashes, the app stops, web server and FTP stop responding, MAX cannot communicate with the device ( I must perform a hard reset).  After reset, viewing the error log using MAX shows no errors.  I've added message logging to see if it stops in a particular place, but see no patterns.  In some cases, the device seems to be continually restarting (every 2-3 minutes) until it finally hangs.  In many instances, my configurations files (used to store runtime variables) have been corrupted or erased.  When trying to deploy the app on this Rio, I generally must try multiple times because I receive the error, "Error deploying on target".  I have tried formatting the flash and reinstalling the OS many times from different sources.
    I'm running Labview 2009, SP1 with the FPGA option. 
    Any ideas on how to diagnose this problem?  Are there any diagnostic tools to test this device?

    Here's a better description of what I'm trying to do.  This system is used to control the head position on a test machine.  I used the LV RT wizard to create the base VI with 1 deterministic loop and 1 non-deterministic.  The deterministic loop schedules 2 different test.  Test 1 is every 5 minutes (collect analog data, read temperatures, calculate new head position based on temperature , drive stepper motors to new position, collect data after moving, then dismiss).  Test 2 runs once a day with a duration of about 4.5 hours (drive stepper motors to user defined position, simulatiously collect data at various rates from 5Hz to .01 Hz, drive head to next user defined position, etc). This test has 2 timed loops running at different rates, one collects data, the other moves the head and acts as a timer to know when to move to the next position.
    If I never run test 2, then the system has never crashed, leading me to believe the problem is in the test 2 VI.  The crashes don't necessarly occur in the Test 2 VI.  On some occations 1-2 hours after Test 2 has completed, the CRIO will start rebooting itself (every 2-3 minutes).  This may happen 4-5 times until it will finally hang completely. 
    Since the crashes happen randomly (it may run for 2-3 days before crashing) I'm trying to find some way of trapping  errors or exceptions that would give me some clue as to what the problem may be. 

  • Can't connect via Airport -- "connection timeout" error, instead

    I've got a MacBook Pro here, which was successfully connected online via Airport, under OS X 10.4.11.
    Then I upgraded to Leopard (10.5), and the machine would no longer connect automatically to the router.
    OK, I tried manually configuring the wireless connection, but no luck. So, I brought in an old iBook G4 running the same OS (10.5), and successfully linked it to the router, wirelessly, via Airport.
    Copying the procedure that worked with the iBook -- to the MBPro -- did not help. Still getting a "connection timeout" error message.
    So I performed a fresh install of 10.5 -- and I even DLed the Software Updates, including two that were supposed to improve Airport functionality -- and tried again. No luck.
    Any suggestions?
    TIA.

    John,
    I had the same problem when I upgraded from Tiger to Leopard in January. My memory is already rusty but try the following:
    1. Go to System Preferences > Network pane. On the left pane, click on AirPort. In the right pane lower right, click Advanced button. Then on the AirPort tab, click on the name of your network and then the minus sign to remove it from the list.
    2. Click Apply and quit System Preferences.
    3. Put the computer to sleep.
    4. Wake the computer.
    5. Go back in to Network preferences, AirPort tab. Click the plus sign to add your network. Fill in the Network Name, choose the type of Security by clicking on the pop-down bar, enter password/code/phrase and click Add. NOTE: Do not connect to the network at this time.
    6. Click Apply and Quit the Network Preferences.
    7. On the Menu row, click the Airport icon and select your network. (IF your network does not show, choose Join Other Network. Fill in the Network Name, choose the type of Security by clicking on the pop-down bar, enter password/code/phrase and click Join.)
    8. Verify connectivity
    9. Put the computer to sleep.
    10. Wake the computer.
    11. Verify connectivity
    HTH

  • Windows Server 2012 Essentials Connection Software not working

    This comes in response to a ticket I got great help from a user on but I'm still stuck on the connection software bit.
    Original Thread: http://social.technet.microsoft.com/Forums/windowsserver/en-US/0a7e6d91-98c7-42f2-9cdd-66117df91d76/win-2012-essentials-not-allowing-client-connections?forum=winserveressentials#0a7e6d91-98c7-42f2-9cdd-66117df91d76
    Summary: All my machines 8 of them up to now have been adding machines using the servername/connect
    Well I have 2 new HP's here Win 7 Pro all updated that WILL NOT get past the asking for the server username/pass screen of the connects software install. I can get them onto the server manually and my GP applies fine, my roaming profiles are working, the
    computer is seen in AD but I have none of the features that are provided by the connect software like dashboard viewing and backups etc.
    The error I get is "The server is not available. Try connecting this computer again, or for more information, see Troubleshoot connecting computers to the server"
    Anyone have any ideas?

    Hi James,
    Based on your description, “Well I have 2 new HP's here Win 7 Pro all updated that WILL NOT get past the
    asking for the server username/pass screen of the connects software install.”, would you please let me confirm whether have reached the page of Windows Server Essentials Connector Configuration Wizard as below picture shows, then can’t go through?
    àI can get them
    onto the server manually and my GP applies fine, my roaming profiles are working, the computer is seen in AD
    Did you mean that add the client computer to windows essentials domain by using traditional method (change
    Workgroup to Domain in System Properties)?
    When this issue occurred, please ping server from the problematic client computer by using server name and
    IP address. Then monitor the result.
    Meanwhile, I noticed your
    original thread that Howtodo have provided some suggestions. As he mentioned, would you please check if Connector software had been installed? Please alos check ClientDeploy log file.
    By the way, did you add the client computer to windows server essentials network via wireless?
    Hope this helps.
    Best regards,
    Justin Gu

  • When I try to scan a document on my MF8050cn, I get a "Connect Computer" error.

    When I try to scan a document on my MF8050cn, I get a "Connect Computer" error.  I am running Windows 8.  My device is directly connected to the computer.  I can print from the computer to the printer without issue.  I get this error when using the controls on the device. 
    If I try to use the MF Toolbox - Scan Function controls, I get the following error message: "This action cannot be completed because the other program is busy.  Choose 'Switch To' to activate the busy program and correct the problem."  When I click "Switch To", it brings me to the Windows 8 tiles screen but does not resolve the issue.
    Please help!

    Hi h_rankin.
    I recommend uninstalling and reinstalling the drivers and software.  Please follow the steps below to perform the operation:
    1.  Unplug the USB cable from the printer.
     2.  Press the Windows key and 'x'.
     3.  Select 'Control Panel'.
     4.  Select Devices and Printers.  The Devices and Printers window opens.
     5.  In the Devices and Printers window, right click on the MF8000 Series and select 'Remove' to delete the printer.  Delete all of the icons for the MF8050Cn.
     6.  Close the Devices and Printers window then press the Windows key and 'x'.
     7.  Select 'Control Panel'.
     8.  Select 'Programs and Features'.
     9.  Double click on driver to uninstall.  Follow the on screen prompts.  Repeat to uninstall the MF Tool box.
    10.  Restart you computer.
    Once your computer restarts, please follow these steps to download and install the drivers and the MF Toolbox from Canon's web site:
     1.  Visit our web site at: http://www.usa.canon.com.
     2.  After clicking SUPPORT & DRIVERS in the top right corner, select your model in the following manner:
         a.  From the first menu, select CONSUMER & HOME OFFICE.
         b.  From the second menu, select PRINTERS & MULTIFUNCTION.
         c.  From the third menu, select your series, IMAGECLASS SERIES.
         d.  From the fourth menu, click DRIVERS & SOFTWARE under imageCLASS MF8050Cn.
     3.  Click the drop-down arrow and change the operating system to Windows 8 (x64).
     4.  Click on 'DRIVERS', then click on [Windows 64bit] imageCLASS MF8050Cn MF Drivers file. 
     5.  Click on I Agree - Begin Download on the next page.
     6.  When the Save As box comes up, choose Desktop and click Save. 
     7.  Once the download is complete, click on 'I Decline- Go Back' and you will return to the previous page.
     8.  Click on 'SOFTWARE', then click on the [Windows 32bit & 64bit] Tool Box Ver.4.9.1 file.
     9.  Click on I Agree - Begin Download on the next page.
    10.  When the Save As box comes up, choose Desktop and click Save. 
    11.  Once the download is complete, close all windows.
    12.  Double click the [ToolBox_4911mf16_Win_EN.exe ] file on the Desktop.  Follow the prompts to install the MF Toolbox.
    13.  Double click the [MF8050Cn_MFDrivers_W64_us_EN_2.exe] files to decompress them.  A new folder will be created on the Desktop.  The new folder has the same name as the decompressed file.  Double-click the decompressed Setup.exe file to start installation.
    14.  Once that window goes away, connect the USB cable from the MF8050Cn to the computer.  Installation will complete.
    Wait a few minutes then scan a document using the MF Toolbox.
    If you still experience any errors, or need any further assistance, please contact us at 1-800-OK-CANON (1-800-652-2666). 
    Have a good day.
    Did this answer your question? Please click the Accept as Solution button so that others may find the answer as well.

  • Varying ON time pulse train generation using NI cRIO-9073 and NI 9401 module

    Hi,
              I am a beginner to the Labview environment.  Am using NI cRIO-9073 and NI 9401 module; and NI Labview 2013. I want to generate 64 pulses, wherein the ON time of the pulses are varying as shown below. The Pulses need to have a constant period of about 34µs. The pulses should have a constant amplitude anywhere from 5 to 10V. I am trying to do the same in FPGA interface mode but failing to do so. Please advise me..... Please also suggest pdf and video resources to learn Labview programming.
    Pulse ON Time
    18 µs
    19 µs
    20 µs
    21 µs
    22 µs
    23 µs
    24 µs
    25 µs
    26 µs
    27 µs
    28 µs
    29 µs
    30 µs
    31 µs
    32 µs
    33 µs
    33 µs
    32 µs
    31 µs
    30 µs
    29 µs
    28 µs
    27 µs
    26 µs
    25 µs
    24 µs
    23 µs
    22 µs
    21 µs
    20 µs
    19 µs
    18 µs
    17 µs
    16 µs
    15 µs
    14 µs
    13 µs
    12 µs
    11 µs
    10 µs
    09 µs
    08 µs
    07 µs
    06 µs
    05 µs
    04 µs
    03 µs
    02 µs
    02 µs
    03 µs
    04 µs
    05 µs
    06 µs
    07 µs
    08 µs
    09 µs
    10 µs
    11 µs
    12 µs
    13 µs
    14 µs
    15 µs
    16 µs
    17 µs

    t81,
    It is possible to make frequency measurements with either the 9422 or the 9425 but each will have its own limitations in the range of frequency it will be able to accurately measure.  
    A few things to know:  
    1. What are the frequency ranges for each sensor (tach and MFM)? More than just knowing Hz/kHz will be helpful.
    2. To what accuracy do you need to measure these signals?
    The 9422 supports a specialty digital configuration counter input that can be configured for frequency measurement (see link)
    http://zone.ni.com/reference/en-XX/help/372603F-01​/riohelprt/crio-9422_rt/
    The specialty mode is only available when using Scan Interface mode, not with FPGA.  
    But the max clock rate in the specifications for the 9422 is 4kHz so this may not be sufficient for the tachometer.  I believe this is the max rate at which the module will update its state no matter how fast the underlying software (RT controller) is running.
    The 9425 has a higher clock rate (~140kHz) but doesn't support the specialty digital mode mentioned above.  It is also a software timed only device but this shouldn't be a problem if you use FPGA.
    Dan

  • FPGA Internal software error

    Hi,
    I'm using labview 2009. When I compile the fpga target vi, i got the following message:
    " An internal software error has occurred. Please contact National Instruments technical support at ni.com/support with the following information:#,910x,907x,911x,783x;781x,785x;784x,9​10x,907x,911x,783x;781x,785x;784x,9101;9102;9103;9​104,9072;9073;9074;9144;9601;9602;9611;9612;9631;9​632;9641;9642,9111;9112;9113;9114;9116;9118,7830;7​831;7833;7811;7813,7851;7852;7853;7854;7841;7842,9​101;9102;9103;9104,9072;9073;9074;9144;9601;9602;9​611;9612;9631;9632;9641;9642,9111;9112;9113;9114;9​116;9118,7830;7831;7833;7811;7813,7851;7852;7853;7​854;7841;7842,Onboard,Onboard,Onboard,Onboard,Onbo​ard,Derived,Derived,Derived,Derived,Derived#,,,,,,​,,,,CONST_TCO_SPI,12.5,13.5,11.25,14.5,12.25,9.25,​13.5,7.5,11.25,8.5CONST_TSU_SPI,2,4,3,2,4,4,4,4,4,​4CONST_TH_SPI,4,4,4,4,4,4,4,4,4,4CONST_TSU_PLUS_TH​_SPI,6,8,7,6,8,8,8,8,8,8#,,,,,,,,,,CONST_TSU_SSMIS​O,6,6,6,6,6,6,6,6,6,6CONST_TH_SSMISO,4,4,4,4,4,4,4​,4,4,4CONST_TSU_PLUS_TH_SSMISO,10,10,10,10,10,10,1​0,10,10,10#,,,,,,,,,,CONST_9201_TCO_SPI,10,10,10,1​4.5,12.25,9.25,10,7.5,11.25,8.5
    Method Name: <b>Compile For Target</b>"
    Does anyone know what caused this problem? Thanks in advance.

    Hello Kb1126,
    To better be able to answer your question could you please share what RIO device you are working with, the RIO device software and any relevent Xilinix tools versions, as well as the possible version installed on your RT target (assuming you are using a RT controller to interface with your FPGA). 
    Thanks,
    Blayne Kettlewell

  • Iphone 5 Screen is Frozen Connection Timeout Error Connection to this app has timed out

    I upgraded to IOS 7 just a few hours before my Iphone 5 screen froze and I cannot make changes -  I have a Connection Timeout Error with Connection to this app has timed out.  With Ok in blue.  The screen doesn't respond,  I can turn off the phone, tap OK or do anthing.  Any advice on how I can reset or fix?

    Check for any anti-virus or anti-spyware software you might have. Temporarily disable that to continue. Normally this is what will cause a timeout. I assume you have a good Internet connection?

Maybe you are looking for