OAF: Error While Formatting a Read Only MessgeTextInput field of an AdvanceTable "$#,##0.00" format.

Hi Gurus,
Please see the below issue I am facing while formatting the field in OAF.
Situation:
Custom BidPG page extends a shared region.(sharedRN.xml)
and in SharedRN I have a advance table, with 5 columns each having  MessageTextInput read only Items.
While the page is getting loaded values are coming from action fired in the PFR. and getting formatted with a $#,##0.00 format. which I have done over bean of all MessageTextInput items
using below code in process request.
Formatter formatter =  new OADecimalValidater("$#,##0.00;($#,##0.00)", "$#,##0.00;($#,##0.00)");
OAMessageTextInputBean NetincPerMac = (OAMessageTextInputBean)webBean.findIndexedChildRecursive("item243");
NetincPerMac.setAttributeValue(ON_SUBMIT_VALIDATER_ATTR, formatter);
Above formatting is working for below cases.
285 becomes $285.00
230.45 becomes $230.45
But in case if there are numbers like 234.254 it will be formatted as $234.254. Here it wont set the precision to 2.
I want to display till only 2 digits after decimal.
please let me know Where I am going wrong or missing some steps to do so.
I have tried below approaches but it did not worked out for me.
          OADecimalValidater dval= new OADecimalValidater("$#,##0.00;($#,##0.00)", "$#,##0.00;($#,##0.00)");
           dval.setMaxPrecision(2);        
          Formatter formatter = dval;
Also , I have tried to set Currency Code as well to USD but it didnot worked out for me.
Please let me know how we can set the precision to 2.
Please note: in process request I dont have data in the bean, I have tried writing a method in controller and setting precision to 2.but it errored out for NULL values coming from bean in process request.
Please reply. Its an urgent issue needs to be resolved.
Thanks,
Premanshu

On another link I found the following :
BKI4007E
File filename cannot be read. Reason: errno(errno number) errno text.
Explanation:
Data could not be read due to some system error. Check errno text for further information. If this error recurs, this might indicate some hardware problems.
User response:
Contact your system administrator.
The Link:
http://ezbackup.cornell.edu/techsup-v5.4/ibmdocs/messages/html/anrcms5878.htm
Regards,
Siddhesh

Similar Messages

  • PC FORMATTED iPod read by MAC & PC?  MAC formatted iPod read only by MAC?

    Is this how the formatting issue works? I'm looking to buy an iPod for a friend who (I think) has PC.....
    Since I'm a mac person, I want to buy the gift, load some music on, and ship it off to the lucky recipient....but if they have a PC , will it be recongnized once it's plugged in?
    Any info would be helpful.
    Thanks.

    PC FORMATTED iPod read by MAC & PC? MAC formatted iPod read only by MAC? Is this how the formatting issue works?
    Yes, that is how it works.
    Since I'm a mac person, I want to buy the gift, load some music on, and ship it off to the lucky recipient....but if they have a PC , will it be recongnized once it's plugged in?
    Okay, unless you restore your iPod while you're on the Mac, I believe it will still be formatted for a PC.
    (You will not need to restore the iPod for transferring music to it on a Mac unless you want to upgrade the iPod's firmware on a Mac computer, then it will have to be Mac-formatted).
    You see, when you recieve an iPod, it is shipped to you as a Windows-formatted iPod, probably since the majority of the population has PCs, and also, PC-formatted iPods are compatible for music transfer for a Mac also.
    Does that make sense?
    EDIT: Zevoneer has already answered your question, so you can ignore all of my post if you wish.
    -Kylene

  • Event ID 1012 - There was an error while attempting to read the local hosts file

    When I start my Computer after it has been turned off overnight (switched off at the Power supply) I get a Blue screen and have to reboot the PC. in the Event log it has this error: Event ID 1012 - DNS client events - There was an error while attempting
    to read the local hosts file.
    Once the PC has booted evrything is O.K. I can restart the PC with no problems, it only seems to happen if the PC has been switched off for a while.
    I am connected to the net via an Netgear dg834v4 Modem/Router
    Windows 7 Ultimate
    Intel Q8200 CPU
    2 x 360 Gb HDD
    ATI 4680 !Gb Video Card
    Digital HDA X-Mystique 7.1 Sound Card
    Aver media 777 TV Tuner card.
    Thank you
    jeepers01
    After further Investigation it seems that this error is Not responsible for my Blue screening......I started my PC after leaving it off all night, and it started normally, but i still have this error in the Event Log - System.....I have searched the Technet
    forums (and there is a lot of ID 1012 errors) but non relating to my problem....If anyone knows what is causing this error and how to fix it, i'd be Grateful....although it does not seem to affect the PC in any way that i can see.
    thanks
    jeepers01

    Since Windows system uses separated user mode and kernel mode memory space, stop errors are always caused by kernel portion components, such as a third-party device drivers, backup software or anti-virus services (buggy services).
    The system goes to a BSOD because there is some exceptions happened in the kernel (either the device driver errors or the service errors), and Windows implements this mechanism: When it detects some errors occur in the kernel, it will kill the box in case
    some more severe damage happens. Then we get a blue screen or the system reboots (it depends on what the system settings are).
    To troubleshoot this kind of kernel crash issue, we need to debug the crashed system dump. Unfortunately, debugging is beyond what we can do in the forum. A suggestion would be to contact Microsoft Customer Service and Support (CSS) via telephone so that
    a dedicated Support Professional can assist with your request. Please be advised that contacting phone support will be a charged call.
    To obtain the phone numbers for specific technology request please take a look at the web site listed below:
    Microsoft - Help and Support
    If you are outside the US please see
    Microsoft Worldwide Home for regional support phone numbers.
    Meantime we can try some available steps as a general troubleshoot.
    1. Please remove the antivirus and run the system with a period. If the issue does not occur, mainly focus on antivirus settings and compatibility. 
    2. Disable Automatic Restart and see detail information on the blue screen.
    1).Click Start, in the Start Search box enter sysdm.cpl.
    2).Click the tab Advanced. Under Startup and Recovery, click the Settings button.
    3). Uncheck “Automatically restart”.
    4). On the drop-down menu “Write debugging information”, choose “Small memory dump”.
    5). Click OK.
    When Blue Screen displays, you may find some useful information.
    Arthur Xie - MSFT

  • When I try to install Itunes, I get this error: (translated from Norwegian) There was a network error while trying to read from the file: C: \ windows \ installer \ iTunes.msi I have tried many times to reinstall, but nothing helps, please help me.

    When I try to install Itunes, I get this error: (translated from Norwegian) There was a network error while trying to read from the file: C: \ windows \ installer \ iTunes.msi I have tried many times to reinstall, but nothing helps, please help me.

    (1) Download the Windows Installer CleanUp utility installer file (msicuu2.exe) from the following Major Geeks page (use one of the links under the "DOWNLOAD LOCATIONS" thingy on the Major Geeks page):
    http://majorgeeks.com/download.php?det=4459
    (2) Doubleclick the msicuu2.exe file and follow the prompts to install the Windows Installer CleanUp utility. (If you're on a Windows Vista or Windows 7 system and you get a Code 800A0046 error message when doubleclicking the msicuu2.exe file, try instead right-clicking on the msicuu2.exe file and selecting "Run as administrator".)
    (3) In your Start menu click All Programs and then click Windows Install Clean Up. The Windows Installer CleanUp utility window appears, listing software that is currently installed on your computer.
    (4) In the list of programs that appears in CleanUp, select any iTunes entries and click "Remove", as per the following screenshot:
    (5) Quit out of CleanUp, restart the PC and try another iTunes install. Does it go through properly this time?

  • Can I bring up siebel services while DB in read only / Standby Mode

    Hi,
    I am trying to bring up the siebel services while DB is in read only mode..
    Can I bring up siebel services while DB in read only / Standby Mode ???

    Hi ,
    Not sure. But I think you can, since bringing up the siebel service require some query from DB and some readings from the gateway.
    Cheers

  • Invalid data has been used to update the list item. The field you are trying to update may be read only (Lookup Field).

    Hi.
    I am getting below error while adding value to look-up field.
    Invalid data has been used to update the list item. The field you are trying to update may be read only.
    I have tried many forums ans post but didn't come to know what's the root cause of issue. I am also posting Code for creating and adding lookup field.
    CAML to create lookup field (It works Fine)
    string lkproductNumber = "<Field Type='Lookup' DisplayName='Product Number' StaticName='ProductNumber' ReadOnly='FALSE' List='" + pNewMaster.Id + "' ShowField='Product_x0020_Number' />";
    Code to insert value to lookup field
    ClientContext client = new ClientContext(SiteUrl);
    client.Load(client.Web);
    client.Credentials = new NetworkCredential(this.UserName, this.Password, this.Domain);
    // Lookup Lists
    List pmList = client.Web.Lists.GetByTitle("Product_Master");
    //List Conatining Lookup Columns
    List piList = client.Web.Lists.GetByTitle("Product_Inventory");
    client.Load(piList);
    query.ViewXml = "<View/>";
    ListItemCollection collection = pmList.GetItems(query);
    client.Load(collection);
    client.ExecuteQuery();
    int prodid=0;
    foreach (ListItem item in collection)
    if (Convert.ToString(item["Product_x0020_Number"]) == ProductNumber)
    { prodid = Convert.ToInt32(item["ID"]); }
    ListItem piItem = piList.AddItem(new ListItemCreationInformation());
    piItem["Product_x0020_Number"] = new FieldLookupValue() { LookupId = prodid };
    piItem.Update();
    client.ExecuteQuery();
    Exception Detail
    Microsoft.SharePoint.Client.ServerException was caught
    Message=Invalid data has been used to update the list item. The field you are trying to update may be read only.
    Source=Microsoft.SharePoint.Client.Runtime
    ServerErrorCode=-2147352571
    ServerErrorTypeName=Microsoft.SharePoint.SPException
    ServerStackTrace=""
    StackTrace:
    at Microsoft.SharePoint.Client.ClientRequest.ProcessResponseStream(Stream responseStream)
    at Microsoft.SharePoint.Client.ClientRequest.ProcessResponse()
    at WebServiceProviders.ClientServices.NewProductInventory() in Z:\.............ClientServices.cs:line 889
    InnerException:
    Quick response is highly appreciated.
    Thanks
    Mehar

    Try some thing like below,
    your data value that needs to be update should be in this format "ID of the lookup";#"Title of the Lookup" 
    For example,
    listItem["Product_x0020_Number"]
    = "1;#iPhone";
    listItem["Product_x0020_Number"]
    = "2;#Mobile";
    Hope this helped you....

  • How to right align a read only numeric field in a panel form layout

    Hi, does anyone know how to right align a read only numeric field in a panel form layout? I am using: Style Class = AFFieldNumberMarker, but it only seems to work if the field is disabled. Disabling the field gives it a difference appearance that does not look right on our forms. These are calculated fields, which cannot be modified, so read only is necessary.
    I have looked online for some answers, and it seems that others are having similar issues.
    I have tried different combinations for the properties, but so far I cannot get it to work.
    Thanks
    Judy
    I am using JDEV 11.1.1.5

    Sorry for the delay in my response. Here is the code
    <af:inputText value="#{bindings.TotalAirlineCostEst.inputValue}"
    label="#{bindings.TotalAirlineCostEst.hints.label}"
    required="#{bindings.TotalAirlineCostEst.hints.mandatory}"
    columns="#{bindings.TotalAirlineCostEst.hints.displayWidth}"
    maximumLength="#{bindings.TotalAirlineCostEst.hints.precision}"
    shortDesc="#{bindings.TotalAirlineCostEst.hints.tooltip}"
    id="it20" readOnly="false"
    disabled="true"
    styleClass="AFFieldNumberMarker">
    <f:validator binding="#{bindings.TotalAirlineCostEst.validator}"/>
    <af:convertNumber groupingUsed="true"
    pattern="#{bindings.TotalAirlineCostEst.format}"
    type="number"
    maxFractionDigits="0"/>
    </af:inputText>
    thank you,
    Judy

  • OVS on read-only input field

    OVS will not allow me to change the value of a read-only input field.  If the input field is set to read-only, the OVS selection table does not display an 'OK' button, only close.
    Value cannot be copied (field is not editable)
      I do not want the field to be editable on the screen, but only allow input via the selected row in the OVS.  Any suggestions?
    Edited by: Bob DeNuto on Jul 31, 2008 1:22 AM

    Using Dictionary Search Help and OVS in this case will disable the Copy button and you don't have any control.
    Use Freely Programmed Value Help, this will solve your problem
    https://wiki.sdn.sap.com/wiki/display/WDABAP/Freelyprogrammedinput+help
    how to provide f4 help to the read only input field
    Abhi

  • Error ora-12028 while creating a read-only snapshot

    Hi !
    I'm in trouble creating a read-only snapshot of a simple table.
    The Master table belongs to an ORACLE 7.3.4 database instance, while the snapshot site belongs to an ORACLE 8.1 database. The read-only snapshot should have a refresh type FAST, but while I'm running the CREATE SNAPSHOT statement in the snapshot site I receive the following message:
    "ORA-12028 snapshot type is not supported by master site string
    Cause: Pre-Oracle master sites are not able to support primary key or
    subquery snapshots that are able to perform a fast refresh.
    Action: Create a ROWID snapshot or use a master table from an Oracle8 site. "
    This message doesn't help me enough. Is there anyone who can give me an advice ?
    Thanks you all.
    Laura

    Well laura earlier version doesn't support snap shot based on primary key
    u should disable primary key constraint from master site
    and create snap shot on the basis of row id.
    for further detail mail me at [email protected]

  • T60 - Error while attempting to read the boot configuration data

    Hello,
    My wife just got an IBM-certified "pre-owned" T60 (type 2007 66U) running XP a few days ago. I updated all the drivers & patches and handed it over to her in good working order.
    This morning when she turned it on, she encountered a message from the Windows Boot Manager:
    Windows failed to start. A recent hardware or software change might be the cause. To fix the problem:
     1) Insert your Windows installation disc
     2) Language settings
     3) Repair your computer
    If you do not have this disc....
    File: \Boot\BCD
    Status: 0xc000000f
    Info: An error occurred while attempting to read the boot configuration data
    It almost goes without saying that we do not having our Windows installation disc as it was pre-installed by Lenovo. I've tried using F11 (after enabling it per other threads on this site) to access the recovery partition but it only takes me directly to the Windows Boot Manager error screen.
    How do I go about repairing this BCD/Windows installation so we can continue our life?
    Thanks...

    You said that the computer is running Windows XP, but unless i'm wrong BCD (Boot Configuration Data) is a new feature starting with Windows Vista and also used by Windows 7. Windows XP use NTLDR (NT Loader) so if BCD is corrupted it sounds to me like someone tried to install Vista og Win7 on the computer or there might have been some leftovers from the previous owner. I don't think you have any other option but to use a Windows CD/DVD to fix this problem since you won't be able to boot from this computer. There might be some 3part utilities available that should be able to fix this, but i wouldn't know what that might be. My recommendation would be to get a Windows CD/DVD.
    -gan

  • Textarea formatting for read-only display

    Hello,
    I currently have a textarea field that is on a data entry screen, which can be displayed as editable or read-only, based on certain criteria. I noticed that when text with line breaks is entered into the textarea, it keeps these line breaks as expected when viewing the record again in edit mode. However, when the record is read-only, and the textarea is showing as read-only text, the formatting has been an issue -- all of the text is run together as if it were one continuous line. In the Label area of properties for the textarea, I added in <PRE> in the Pre Element Text value, and </PRE> for the Post Element Text, to retain formatting of the text. The good news is that now the text formats properly in edit or read-only mode; however, if a long amount of text was entered before a line break, when viewing the textarea as read-only, the text goes on and on far past the right edge of the screen so a lot of scrolling must be done to read the text.
    Is there some property or workaround I can use to restrict the width of the text showing when read-only, so the text will wrap but also maintain line breaks? I don't want to change any properties that will cause the edit view of of this textarea to function any differently. In a nutshell, I'd like to be able to have the text wrap, but still show the line breaks.
    Thanks in advance,
    Brian

    Yes, I had the same issue.
    Read only with textarea .
    It is not fixed in 3.0 version I don't know if it is in 3.0.1.
    My workaround was to use javascript to change the property of the textarea to readonly on page load event upon certain condition, something like :
    if ('&P8_EMP_TYPE.' != 'EMP' || '&P8_DATE.' != ''){
    document.getElementById('P8_EMP_COMMENTS').readOnly = true}
    You should be able to do something similar with most conditions, if you find a better workaround pls let me know.
    George

  • Read-only input field error

    I have an input field marked read-only on a form.  When I run the application, select the read-only field, press enter, then Save (validating action), I get a WebDynpro exception saying that I attempted to modify a read-only context attribute.  This does not happen if I select the field and press other keys (such as characters)...  only when I press enter.  If I make the field disabled (instead of read-only), this error is avoided because I cannot even select the input field - but I would rather use read-only because it doesn't gray out the field at runtime.  Is this a bug, or am I missing something?
    -Dave

    When you select the inputField and press enter the OnEnter action of the inputField is being called.
    When you disable the inputField it prevents you from entering values as well as accessing it actions also.
    When you try to keep you context attribute as read only and keep the input field as enabled it is similar to trying to modify a read only attribute which is not permissible.
    Hence the error.
    Revert for further clarifications.
    Message was edited by: Noufal Kareem

  • Time Machine backup fails w/error: Backup Volume is Read Only

    This is another Leopard Bug! My Time Machine has always "just worked," but tonight, backup failed. Looking at the error message, it says, "Backup Volume is Read Only." My Time Machine was set up correctly, and has been working fine for quite some time. Now what?

    Update: The next scheduled backup succeeded. I didn't change anything. Doesn't exactly give you that feeling of confidence in your equipment. The whole point of Time Machine is it is supposed to work in the background. If I have to think about it, and check up on it, it is useless, and I may as well return to my old manual backup methods.

  • Standby database errors - Alter database open read only

    alter database open read only
    AUDIT_TRAIL initialization parameter is changed to OS, as DB is NOT compatible for database opened with read-only access
    Signalling error 1152 for datafile 1!
    Beginning standby crash recovery.
    Serial Media Recovery started
    Managed Standby Recovery starting Real Time Apply
    Media Recovery Waiting for thread 1 sequence 216
    Mon Dec 20 11:58:18 2010
    Standby crash recovery need archive log for thread 1 sequence 216 to continue.
    Please verify that primary database is transporting redo logs to the standby database.
    Wait timeout: thread 1 sequence 216
    Standby crash recovery aborted due to error 16016.
    Errors in file /u01/app/oracle/diag/rdbms/mdm2/MDM2/trace/MDM2_ora_17442.trc:
    ORA-16016: archived log for thread 1 sequence# 216 unavailable
    Recovery interrupted!
    Completed standby crash recovery.
    Signalling error 1152 for datafile 1!
    Errors in file /u01/app/oracle/diag/rdbms/mdm2/MDM2/trace/MDM2_ora_17442.trc:
    ORA-10458: standby database requires recovery
    ORA-01152: file 1 was not restored from a sufficiently old backup
    ORA-01110: data file 1: '+MDMDG1/mdm2/datafile/system.280.738243341'
    ORA-10458 signalled during: alter database open read only...
    Mon Dec 20 12:13:46 2010
    ALTER DATABASE RECOVER managed standby database using current logfile disconnect
    Attempt to start background Managed Standby Recovery process (MDM2)
    Mon Dec 20 12:13:46 2010
    MRP0 started with pid=23, OS id=18974
    MRP0: Background Managed Standby Recovery process started (MDM2)
    started logmerger process
    Mon Dec 20 12:13:51 2010
    Managed Standby Recovery starting Real Time Apply
    Parallel Media Recovery started with 2 slaves
    Waiting for all non-current ORLs to be archived...
    All non-current ORLs have been archived.
    Media Recovery Waiting for thread 1 sequence 216
    Completed: ALTER DATABASE RECOVER managed standby database using current logfile disconnect
    The above lines are from alert log of standby database.
    Standby standbase
    SQL> alter database open read only;
    alter database open read only
    ERROR at line 1:
    ORA-10458: standby database requires recovery
    ORA-01152: file 1 was not restored from a sufficiently old backup
    ORA-01110: data file 1: '+MDMDG1/mdm2/datafile/system.280.738243341'
    Parameters set on primary are
    log_archive_dest_1 LOCATION=+MDMDG3/MDM1/ARCH VALID_FOR=(ALL_LOGFILES,ALL_ROLE ) DB_UNIQUE_NAME=MDM1
    log_archive_dest_state_1 ENABLE
    log_archive_dest_2 SERVICE=MDM2 SYNC VALID_FOR=(ONLINE_LOGFILES,PRIMARY_ROLE) DB_UNIQUE_NAME=MDM2
    log_archive_dest_state_2 ENABLE
    dg_broker_config_file1 +MDMDG2/mdm/dg_config/dgconfig1_mdm.dat
    dg_broker_config_file2 +MDMDG2/mdm/dg_config/dgconfig2_mdm.dat
    fal_server MDM2
    standby_file_management AUTO
    log_archive_config dg_config=(MDM1,MDM2)
    db_file_name_convert MDM2, MDM1
    ALTER DATABASE SET STANDBY DATABASE TO MAXIMIZE availability ;
    Standby pfile
    *.archive_lag_target=900
    *.audit_file_dest='/u01/app/oracle/admin/MDM2/adump'
    *.audit_trail='db'
    *.compatible='11.2.0.0.0'
    *.control_files='+MDMDG1/MDM2/CONTROLFILE/controlfile01.ctl','+MDMDG2/MDM2/CONTROLFILE/controlfile02.ctl'
    *.db_block_size=8192
    *.db_create_file_dest='+MDMDG1'
    *.db_domain=''
    *.db_file_name_convert='MDM1','MDM2'
    *.db_name='MDM'
    *.db_recovery_file_dest='+MDMDG2'
    *.db_recovery_file_dest_size=10485760000
    *.db_unique_name='MDM2'
    *.dg_broker_config_file1='+MDMDG2/MDM/DG_CONFIG/dgconfig1_MDM.dat'
    *.dg_broker_config_file2='+MDMDG2/MDM/DG_CONFIG/dgconfig2_MDM.dat'
    *.diagnostic_dest='/u01/app/oracle'
    *.dispatchers='(PROTOCOL=TCP) (SERVICE=MDM2XDB)'
    *.fal_server='MDM11','MDM12'
    *.instance_name='MDM2'
    *.log_archive_config='dg_config=(MDM1,MDM2)'
    *.log_archive_dest_1='LOCATION=+MDMDG3/MDM2/ARCH VALID_FOR=(ALL_LOGFILES,ALL_ROLES) DB_UNIQUE_NAME=MDM2'
    *.log_archive_dest_2='SERVICE=MDM1 ASYNC VALID_FOR=(ONLINE_LOGFILES,PRIMARY_ROLE) DB_UNIQUE_NAME=MDM1'
    *.log_archive_dest_state_1='ENABLE'
    *.log_archive_dest_state_2='ENABLE'
    *.log_archive_format='MDM_%t_%s_%r.arc'
    *.log_file_name_convert='MDM1','MDM2'
    *.memory_target=838860800
    *.nls_language='ENGLISH'
    *.nls_territory='UNITED KINGDOM'
    *.open_cursors=300
    *.processes=500
    *.remote_login_passwordfile='exclusive'
    *.sessions=555
    *.standby_file_management='AUTO'
    *.undo_tablespace='UNDOTBS1'
    On standby ASM
    ASMCMD [+] > find * *
    +MDMDG1/ASM/
    +MDMDG1/ASM/ASMPARAMETERFILE/
    +MDMDG1/ASM/ASMPARAMETERFILE/REGISTRY.253.737811541
    +MDMDG1/MDM/
    +MDMDG1/MDM2/
    +MDMDG1/MDM2/CONTROLFILE/
    +MDMDG1/MDM2/CONTROLFILE/controlfile01.ctl
    +MDMDG1/MDM2/CONTROLFILE/current.265.738243333
    +MDMDG1/MDM2/DATAFILE/
    +MDMDG1/MDM2/DATAFILE/CANVAS_POPULARITY_DATA.264.738243343
    +MDMDG1/MDM2/DATAFILE/CANVAS_POPULARITY_IDX.277.738243343
    +MDMDG1/MDM2/DATAFILE/MDM_SRC_DATA.282.738243343
    +MDMDG1/MDM2/DATAFILE/MDM_SRC_IDX.275.738243343
    +MDMDG1/MDM2/DATAFILE/MIPS_MDM_DATA.283.738243341
    +MDMDG1/MDM2/DATAFILE/MIPS_MDM_IDX.276.738243343
    +MDMDG1/MDM2/DATAFILE/SYSAUX.281.738243341
    +MDMDG1/MDM2/DATAFILE/SYSTEM.280.738243341
    +MDMDG1/MDM2/DATAFILE/TEST_TBSP1.273.738243345
    +MDMDG1/MDM2/DATAFILE/TEST_TBSP2.272.738243345
    +MDMDG1/MDM2/DATAFILE/UNDOTBS1.256.738243343
    +MDMDG1/MDM2/DATAFILE/UNDOTBS2.279.738243343
    +MDMDG1/MDM2/DATAFILE/USERS.278.738243347
    +MDMDG1/MDM2/ONLINELOG/
    +MDMDG1/MDM2/ONLINELOG/group_1.259.738243429
    +MDMDG1/MDM2/ONLINELOG/group_2.257.738243431
    +MDMDG1/MDM2/ONLINELOG/group_21.284.738243505
    +MDMDG1/MDM2/ONLINELOG/group_22.261.738243505
    +MDMDG1/MDM2/ONLINELOG/group_23.274.738243505
    +MDMDG1/MDM2/ONLINELOG/group_3.258.738243431
    +MDMDG1/MDM2/ONLINELOG/group_31.262.738243513
    +MDMDG1/MDM2/ONLINELOG/group_32.270.738243513
    +MDMDG1/MDM2/ONLINELOG/group_33.263.738243513
    +MDMDG1/MDM2/ONLINELOG/group_4.260.738243431
    +MDMDG2/MDM/
    +MDMDG2/MDM/DG_CONFIG/
    +MDMDG2/MDM2/
    +MDMDG2/MDM2/AUTOBACKUP/
    +MDMDG2/MDM2/AUTOBACKUP/2010_12_20/
    +MDMDG2/MDM2/AUTOBACKUP/2010_12_20/s_738242861.263.738244155
    +MDMDG2/MDM2/CONTROLFILE/
    +MDMDG2/MDM2/CONTROLFILE/controlfile02.ctl
    +MDMDG2/MDM2/CONTROLFILE/current.271.738243335
    +MDMDG2/MDM2/ONLINELOG/
    +MDMDG2/MDM2/ONLINELOG/group_1.270.738243429
    +MDMDG2/MDM2/ONLINELOG/group_2.269.738243431
    +MDMDG2/MDM2/ONLINELOG/group_21.268.738243505
    +MDMDG2/MDM2/ONLINELOG/group_22.272.738243505
    +MDMDG2/MDM2/ONLINELOG/group_23.262.738243505
    +MDMDG2/MDM2/ONLINELOG/group_3.273.738243431
    +MDMDG2/MDM2/ONLINELOG/group_31.266.738243513
    +MDMDG2/MDM2/ONLINELOG/group_32.265.738243513
    +MDMDG2/MDM2/ONLINELOG/group_33.264.738243513
    +MDMDG2/MDM2/ONLINELOG/group_4.261.738243431
    +MDMDG3/MDM/
    +MDMDG3/MDM/ARCH/
    +MDMDG3/MDM2/
    +MDMDG3/MDM2/ARCH/
    -- Please can I know how to open read only standby database.

    user5846399 wrote:
    ORA-16016: archived log for thread 1 sequence# 216 unavailable
    Recovery interrupted!archived log for thread 1 sequence# 216
    This file is needed for recovery, Find it and move it to the standby database side.

  • Error Backup volume is read only

    Time machine is giving me an error message of backup volume is read only.
    I am using a time capsule for the backup disk
    How do I change from read only to read and write?

    I erased my TC and started over. It seemed to work fine until I tried to see my backups, it crashed. I've switched to Déjà Vu: http://propagandaprod.com/
    I've been using this back up software for years with out ever having problems, I switched to Time Machine because I liked the fact that you could replace one pictures from iPhoto or one Address instead of the hole library. But I can't risk my work, I was never a fan of using Disk Images as backup, they get corrupted to often. Déjà Vu Works perfect with TC so I'm going back to Old Reliable. Plus it doesn't hog up your Hard Drive space. It could Mirror your files, it has a safety net option where you could pick how many days to save, and it only backs up once a Day, Week or month. Which is better than every hour.

Maybe you are looking for