PAP2T is Droppiing DIal Tone after around 1 hour when connected to D-Link DSL-504G

I have recently changed my router to a D-Link DSL-504G and now my PAP2T looses dial tone randomly but usually after 15 -60 mins of use.  It never comes back on unless I reset the router and PAP2T.  Then it does the same.
I have an external static IP address (ISP) I have a static IP address for my router. I have made a internal static IP address for the PAP2T. I have port forwarded as per my SIP providers instructions (maybe have made an error here?).
I have called D-Link and they don't have a clue. I have upgraded the D-Link to the latest firmware. I have NOT upgraded the PAP2T as it used to work wit h my other router. (Not available anymore)
Is this a configuration problem on the D-Link or is it just incompatible?

Hello,
if you have forwarded SIP ports (5060 and 5061 by default) make sure you also forward the RTP port range (16384-16482). The loss of the dialtone appears to be tight to loss of the registration - which can be related to dead/wrong conntrack entry somewhere on the way between you and your VoIP provider.
Next time you loose the tone try to change "SIP Port" on the line in trouble from 5060 (5061) to something (exotix) else, like 6050 (6051).
You may also consider to completely cancel the port forwarding and use the NAT keeplive ( $INFO or $NOTIFY) every 5 or so minutes (300s) to keep the NAT alive between the $REGISTER requests (which are every 3600s by default AFAIK)

Similar Messages

  • Dial tone after first two digits are dialed

    I was just made aware that one of our sites when dialing out (local, LD, TF, etc) receives dial tone after dialing the first two digits of any number.  They can continue to dial the number and will call out.  I am trying to understand where the dial tone is coming from after the 2nd digit is dialed.  Any idea's?
    CUCM 8.5
    2821 Gateway - MGCP - T1PRI

    I absolutely agree with Aaron's statement that ALL route patterns need to have the 'provide outside dial tone' checked on all applicable route patterns.  I would also like to note that any dial plan overlap with those route patterns would also cause delay in secondary dial tone.
    For example if you dial 9 to get out and a dial-able extension gets added accidentally to a phone that also starts with a 9, that could cause similar issues.
    So after checking route patterns first and if all that looks correct, I recommend Call Routing -> Route Plan Report, to search for ALL numbers that start with your outside access code.

  • Hello . I hope to get a solution to my problem: ( I bought a laptop Mac Pro, a user But the seller was not the Secretary Laptop after arriving I've worked for almost an hour When connected to electricity Nour appears very faint, I do not see it quickly ht

    Hello
    . I hope to get a solution to my problem: (
    I bought a laptop Mac Pro, a user
    But the seller was not the Secretary :" (  !!
    Laptop after arriving I've worked for almost an hour
    * When connected to electricity
    Nour appears very faint, I do not see it quickly
    http://www.3rabart.com/up/download.php?img=38472
    When separated from the energy, light shows intermittently and then disappears fast
    http://www.3rabart.com/up/download.php?img=38473
    I need urgent help please.
    Thank you

    Please ، How Email  for a company ? I want to communicate with them about my problem "(

  • Since upgrading to Mavericks I am finding that I am lucky to get 2 hours (when connected to WiFi) of use from my macbook Pro.

    Since upgrading to Mavericks I am finding that I am lucky to get 2 hours (when connected to WiFi) of use from my Macbook Pro.  I have turned off Bluetooth ( which was not an issue previously), uninstalled Chrome, again not an issue before I upgraded, and have not seen any improvement.
    I was using an older OS system (Snow Leopard) on my 2010 Macbook Pro.  I am wondering now if the upgrade was an unwise move?

    jbuckworth,
    which apps do you run under battery power? Are any of them identified as “apps using significant energy” when you click on the battery icon in the menu bar? If you have a 15-inch or 17-inch model, are your apps using the discrete GPU (which consumes more power than the integrated GPU)?
    How many charge cycles has your battery accumulated?
    How long have you had Mavericks installed? Is Spotlight still reïndexing your boot drive? (It does that whenever your OS is upgraded, because so many files change in an OS upgrade.)

  • Ipod touch for Christmas, but cannot get started: after installing itunes, when connecting to my laptop I get no instruactions, just the error message "This iPod cannot be used because the Aplle Mobile Device service is not started". Any suggestions???

    ipod touch for Christmas, but cannot get started: after installing itunes, when connecting to my laptop I get no instruactions, just the error message "This iPod cannot be used because the Aplle Mobile Device service is not started". Any suggestions???

    Jennifer...
    Follow the instructions here >  iPod touch: How to restart the Apple Mobile Device Service (AMDS) on Windows

  • I installed iCloud yesterday and since my mac book pro is slowing down to almost total freeze after 8 minutes when connected to internet. Anyone knows what to do? Many thanks

    I installed iCloud yesterday and since my mac book pro is slowing down to almost total freeze after 8 minutes when connected to internet. Anyone knows what to do? Many thanks

    Removed trend micro smart crap files from disco and it worked.

  • HomeHub - No landline dial tone after a few hours.

    Hi Guys,
    I have an odd problem with my HomeHub & Phone.
    It seems every few hours my hub phone stops picking up the landline dial tone, if I reset the HomeHub then the dial tone comes back.
    While the HomeHub is not picking up a dial tone it (the HubPhone) will ring when people call, although i'm not sure at this point if I can hear people on the other end of the line as I have only been calling myself to test it.
    If I plug an ordinary landline phone into the HomeHub it also gets no dial tone, if I plug the ordinary phone directly into the landline I get a dial tone and can make calls as normal.
    So that leads me to believe something is not right with my HomeHub.
    Does anybody have any ideas as to what the problem could be before I ask for the Hub to be changed?, i've only had it a week so I would have to be unlucky to get a faulty one.
    I did originally post this issue in the 'phones' section until I knew the issue was with my Hub.
    Thanks

    Hi guys,
    If you haven't already given this a go, try power-cycling the Hub, and while the Hub is restarting power-cycle the Hub Phone as well.
    dallaway, can you try using a different handset as Burge did (it'll give an indication as to whether the Hub handset is faulty or not).
    If this problem continues let us know.
    Stephanie
    Stephanie
    BTCare Community Manager
    If you like a post, or want to say thanks for a helpful answer, please click on the Ratings star on the left-hand side of the post. If someone answers your question correctly please let other members know by clicking on ’Mark as Accepted Solution’.

  • An incoming call from VoIP. The SPA122 generate Dial Tone after the far end hung up rather busy tone.

    Hi All!
    I have a problem with the SPA122 telephony adapter, uncorrectly process the subscriber signaling at the end of the call.
    1) Outbound call from FXS port SPA122 . When a remote caller hangs up first , the subscriber SPA122 Reorder Tone played with a delay specified in the Reorder Delay. This circuit is working properly.
    2 ) Incoming call from VoIP to the SPA122. When a remote caller hangs up first , subscriber on the FXS port of the SPA122 hears silence ~ 3-4 seconds , then SPA122 plays Dial Tone, as if he had just picked up the phone and he 's going to call . No signal lights out (Busy Tone or Reorder Tone) will not play .
    Config is attached.
    Model: SPA122, LAN, 2 FXS
    Hardware Version: 1.0.0 Boot Version: 1.0.1 (Oct 6 2011 - 20:04:00)
    Firmware Version: 1.3.2-XU (014) Jul 2 2013
    Recovery Firmware: 1.0.2 (001)
    WAN MAC Address: 6C:20:56:55:3A:B6
    Host Name: SPA122
    Domain Name: (none)
    Serial Number: CCQ16450LG3
    However, other VoIP terminals registered to Huawei, including older versions of the Linksys SPA2102 work in these scenarios correctly.
    Where to kick it?

    [2] is misconfiguration on your's side. You have CPC turned on, but no CPC capable device. Set CPC Duration to zero to turn off CPC.
    By the way, wrong forum for your question. You should consider to move it to space.

  • Need second dial tone after dialing 9

    Hello, I am trying to configure CCM so when user picks up his phone and dials 9 he is provided with a second dial tone. Usually this is a feature provided by the local PBX but I wanted to know if I can do this on the CCM.

    Hi Farid,
    Check your 9@ Route Patterns for this setting;
    Provide Outside Dial Tone
    Check this check box to provide outside dial tone. To route the call in the network, leave the check box unchecked.
    From this CCM 4.1.3 doc;
    http://www.cisco.com/en/US/products/sw/voicesw/ps556/products_administration_guide_chapter09186a00803ed685.html#wp1023973
    Hope this helps!
    Rob

  • My computer is crashed after 3 hours, when am running an Executable file from LabView 6.0.2

    My VI is using DAQ6025e and GPIB cards, it is countiniusly writing data to files and talking with 2 GPIB instruments and one Serial instrument. Sudenly after 3 hours of perfect working it is crash my computer.
    Does any body know why ??? Help? S.O.S?

    Some questions to help us troubleshoot:
    1)How crashed is your computer when it crashes?
    Blue Screen Of Death crashed? If you don't know about BSOD then that
    is when your computer presents a blue screen (white in XP) and tells
    you that the system is halted, gives you a register dump and the
    memory address where it stopped (all of which is useless unless you
    are an assembly language wizard) and then you have to reboot the
    machine.
    Application error that kills LabVIEW.exe? Usually a pop-up MSGBOX
    style dialog box will appear with a such and such error occurred in
    LabVIEW.exe or another application and an OK button.
    VI Slows to a crawl w/hourglass in the app window? Program doesn't
    stop executing, it just stops responding to user inputs.
    LabVIEW error cluster error that causes the VI to quit?
    2) What O/S are you running? Win 3.1, Win 95, Win 98, Win NT 3.1, Win
    NT 3.5, Win NT 4.0, Win2000, WinME, WinXPHome, Win XPPro?, Linux?, Mac
    O/S?
    In the Microsoft family, WinNT and Win2000 are by far the most stable
    and reliable of the various versions of Windows with Win95 and Win98
    having a lot of problems running for long periods of time. Make sure
    that you get WinNT 4.0 updated to service pack 6 if you are still
    using 4.0 but haven't updated the service pack level yet. There were
    quite a number of problems with it when it first came out that have
    since been cured.
    3) Have you run the LabVIEW VI profiler yet? This will point out
    memory leaks that are due to dynamically built arrays using shift
    registers etc. or appending to strings, or improper IMAQ management,
    etc.
    4) Have you brought up the task manager and looked at the memory
    allocated for LabVIEW.exe and for the whole system as well? Is it
    growing? Sometimes there can be memory leaks that don't show in the
    profiler that will show in the task manager when you look. These can
    be due to bugs in LabVIEW itself or some driver for some hardware you
    are using, etc.
    If you are not running NT or a later derivative, then you won't have
    task manager available but you can get diagnostic tools that are very
    similar to task manager from off the web.
    5) How much memory do you have in your PC? How fast is your PC? What
    does the CPU % usage look like under task manager when you first start
    your app? If it is running >40% CPU usage for any significant amount
    of time at the start then perhaps your PC is overloaded with work and
    you need a faster PC or your code needs redesigning. I like data
    acquisition systems to operate <25% generally speaking. This number
    seems to improve the reliability of the code that is running on them.
    6) How much H/D space is available? You say you are writing data to
    files. Your h/d space isn't running out is it?
    7) Is it possible to run one instrument at a time for several hours to
    see if it is a particular instrument that is causing the crash? Make
    sure that your GPIB cards are properly configured so that they don't
    share resources with any other devices(IRQ, DMA, memory addresses,
    etc.) It may be possible that they behave fine most of the time even
    with shared resources but if they ever try to send a command
    simultaneously and they share resources, they could "collide" and
    crash your PC. You can check all this out in the control panel and/or
    MAX.
    8) Is it possible that your serial port is getting hung up after
    running a long period of time? Serial port UARTS are notoriously
    finicky especially over longer line lengths and higher data rates. It
    could be that your serial instrument is locking up your app or your PC
    serial port is locking up your app and causing the crash. Can you put
    a serial port analyzer in between your serial instrument and your PC
    to see what's going on when it crashes?
    9) Are you trying to read or write to the serial port in more than one
    thread or while loop or dynamically launched vi? If you are you MUST
    protect the serial port access with a semaphore or a VISA resource
    lock. You CANNOT use a boolean global to protect access. Regular
    globals aren't atomic and you can have race conditions that result in
    unintended serial port collisions between differen threads. I have
    seen this lock up multi-threaded serial programs before to the point
    of requiring rebooting.
    This problem can be especially frustrating if you haven't done
    multi-threaded before. The port won't necessarily lock up right away
    or at the same time every time. You MUST make sure that serial port
    access is limited to ONLY ONE execution thread at a time.
    10) Is there another application or service running in the background
    with your application that may be trying to access the serial port or
    GPIB cards when you aren't expecting it? This could cause a collision
    that could crash your system as well.
    Douglas De Clue
    LabVIEW developer
    [email protected]
    Yan wrote in message news:<[email protected]>...
    > My VI is using DAQ6025e and GPIB cards, it is countiniusly writing
    > data to files and talking with 2 GPIB instruments and one Serial
    > instrument. Sudenly after 3 hours of perfect working it is crash my
    > computer.
    > Does any body know why ??? Help? S.O.S?

  • Mac resets after 1 hour when using ATV

    When viewing a movie that is on my Mac via my ATV the Mac resets after 1 hour and I have to physically log in again to continue.
    ATV is ethernet connected via a D-Link switch.

    Exactly, it only logs out when I use the ATV and It is always 1 hour.
    The ATV is connected via ethernet through a D-Link DIR-655 switch so I am wondering if it could be something in the switch settings, (multicast streams?)

  • Why is the ios7 draining my battery by 50% after three hours when i havent used it?

    My iphone 5 has been updated to ios7,
    the battery life if appauling, i have lost 50% of the battery over three hours when i havent even used it,
    i also am  unable to delete my open apps?
    the apps keep freezing when i do use it,
    This is ridiculous i am really annoyed with this update as i am unable to use my phone or it will die seconds later!

    Well, you could start by searching the forum. You might then find this: https://discussions.apple.com/thread/3391947?tstart=0, a thread with over a million views and over ten thousand posts, discussing this very subject.
    But the short answer is you have an app that is using data and power. If you have an Exchange account it might be email if you get a lot of messages. If you have the FaceBook app it is almost certainly that. Exiting out of apps does not necessarily kill the background process if they are built in apps (like mail, contacts and calendar, ping, genius, iTunes). Other apps can re-launch their background tasks if they are set to receive notifications and the receive one.

  • Suddenly Error -17306 in LV-Operato​r-Interfac​e after 3 hours when trying to read a StationGlo​bal

    Hello,
    i´m using the example-labview-operator-interface with some modifications.
    One of the changes is that i created a Thread (UserEcentCallback.vi) which reads a value from the StationGlobals and displays it on the OP.
    This thread is running in a loop and executed every second. This worked fine for ~ 3hours and suddenly the attached error-message appeared.
    What can i do to prevent this problem?
    I´m using the default "TestStand Get Property Value.vi" to read the Globals.
    Thanks for all tips.
    Attachments:
    error4.JPG ‏66 KB

    Hi,
    That seems a strange one, especially seeing the VI before it must have found the property ProjectParameter as it read State_Mode without problems.
    I guessing ProjectParameter is still present in your StationGlobals after the error occurred!
    As to what to do, you could do a Check to make sure the property exists before reading the data.
    Regards
    Ray
    Regards
    Ray Farmer

  • Suddenly Error -17306 in LV-Operator-Interface after 3 hours when trying to read a StationGlobal

    Hello,
    i´m using the example-labview-operator-interface with some modifications.
    One
    of the changes is that i created a Thread (UserEcentCallback.vi) which
    reads a value from the StationGlobals and displays it on the OP.
    This
    thread is running in a loop and executed every second. This worked fine
    for ~ 3hours and suddenly the attached error-message appeared.
    What can i do to prevent this problem?
    I´m using the default "TestStand Get Property Value.vi" to read the Globals.
    Thanks for all tips.
    (Sorry for double posting, buut i dont know if this is a labview or teststand-problem)
    Attachments:
    error4.JPG ‏66 KB

    Hi,
    That seems a strange one, especially seeing the VI before it must have found the property ProjectParameter as it read State_Mode without problems.
    I guessing ProjectParameter is still present in your StationGlobals after the error occurred!
    As to what to do, you could do a Check to make sure the property exists before reading the data.
    Regards
    Ray
    Regards
    Ray Farmer

  • My iPod Touch 5 won't turn on.A minute before it was working perfectly fine and then i locked it. after an hour when i check on my itouch. it won't open. they say try to restart it using the lock home button trick.My home button is broken what to do?

    please someone help me now.

    Connect the iPod to your computer and restore via iTunes
    iTunes: Restoring iOS software
    If still problem, make an appointment at the Genius Bar of an Apple store since it appears you have a hardware problem besides the Home button.
      Apple Retail Store - Genius Bar                              

Maybe you are looking for