Problem creating switch virtual link

I have two brand-new Catalyst 4500X switches running cat4500e-UNIVERSALK9-M. The switch has GLC-T 10Gbs copper SFPs in it. All the ports are set to "switchport"
I am trying to crate a VSS pair, but I cannot bundle interfaces T2/7 & 8. I am getting error:
Te2/8 is not compatible with Po10 and will be suspended (trunk mode of Te2/8 is dynamic, Po10 is trunk)
I followed the procedure as follows
Switch1:
switch virtual domain 5
switch 1
switch 1 priority 110
switch 2 priority 100
interface port-channel 10
switchport
switch virtual link 1
no shut
interface range ten 2/7 & 8
channel-group 10 mode on
Switch 2:
switch virtual domain 5
switch 2
switch 1 priority 110
switch 2 priority 100
interface port-channel 20
switchport
switch virtual link 2
no shut
interface range ten 2/7 - 8
channel-group 20 mode on
If I look at the config on switch 1, it looks correct
interface TenGigabitEthernet2/7
 switchport mode trunk
 switchport nonegotiate
 no lldp transmit
 no lldp receive
 no cdp enable
 channel-group 10 mode on
 service-policy output VSL-Queuing-Policy
interface TenGigabitEthernet2/8
 switchport mode trunk
 switchport nonegotiate
 no lldp transmit
 no lldp receive
 no cdp enable
 channel-group 10 mode on
 service-policy output VSL-Queuing-Policy
But po10 is down (waiting to aggregate)
Is there something I am missing here? What am I doing wrong?

I can answer my own question here
the error is "transient" and goes away after the conversion process is complete. Po10 in this instance will not come up until conversion, despite what it says in the official documentation

Similar Messages

  • Problem- Create Remote Delta link in Federated Portal Network environment

    Dear Experts,
    I am working in a Fedeated protal network environment where the producer is  BI 7.0 Portal and the EP portal is the consumer.
    FPN was already configured at client side and some reports were already integrated .
    Now i am working to integrate some other BI reports and need to work on PCD  ( creating iviews/pages/worksets/roles )..for integrating the BI reports.
    I followed to create th remote delta link for content of producer  in the consumer portal as following .
    1.In consumer portal i navigated to the  Portal catalog of NetWeaver Content Producers
    2 .Browse the Portal Catalog of the remote producer and then, choose Copy.
    3.Right-click a folder in conusmer local Portal Catalog (in the Portal Content root folder) and then choose Paste as Local Content.
    While perfoming third step i am getting following error
    "*Could not create remote delta link to object'pcd:portalcontent/com.analog.analog/hcm_bi_reports/iviews/basic_reports/com.analog.cost_center_report'Could not connect to producer portal. Please check that the producer portal is running, there are no network problems, and your consumer settings for the producer are configured properly_* "
    Producer potal is already in running mode and producer content is get dispalying in consumer portal under NetWeaver Content Producers.
    Could any body help me what might be the problem.
    i would appriciate if you replied for the same.
    Thanks and Regards
    Ratnakar

    Hi,
    Could you try to set the log level ALL for com.sap.portal.fpn and its subtree (From log configurator service in Visual Administration)?
    Then see the log messages in the default.trc logs and possibly post them to this threads.
    Regards
    Dagfinn

  • Problem creating a database link

    Hi,
    I tried to create a database link, but it doesn't work. When I connect to the database via SQL*Plus or SQL Developer, the entries in the tnsnames.ora work.
    create database link DBOPBWS2.BAG connect to demo identified by demo
    using 'DBOPBWS2.BAG';
    Entry in tnsnames.ora:
    DBOPBWS2.BAG =
      (DESCRIPTION =
        (ADDRESS = (PROTOCOL = TCP)(HOST =serv01.server.spub-systeme.de)(PORT = 1485))
        (CONNECT_DATA =
          (SERVER = DEDICATED)
          (SID = DBOPBWS2)
    Entry in sqlnet.ora:
    NAMES.DIRECTORY_PATH= (TNSNAMES, EZCONNECT)
    select * from [email protected];
    Error:
    ORA-12154: TNS: Angegebener Connect Identifier konnte nicht aufgelöst werden
    12154. 00000 - "TNS:could not resolve the connect identifier specified"
    What is wrong with the datbase link?
    Please help me
    Siegwin

    Hi,
    You could also "skip" the TNSNAMES use :Scott@my11g SQL>create database link DBOPBWS2.BAG connect to demo identified by demo
    using '(DESCRIPTION = (ADDRESS = (PROTOCOL = TCP)(HOST =serv01.server.spub-systeme.de)(PORT = 1485)) (CONNECT_DATA = (SERVER = DEDICATED) (SID = DBOPBWS2)))'
    Database link created.

  • Problem Creating Internal pdf Links In Preview

    I am trying to create internal links in a pdf file within Preview. When I "Set Destination" to a particular page within the file, the link always goes to the page after the one I set. The strange thing is that when I view the same file on a Windows PC it works right. Any ideas how to fix?

    Did you ever find out why this happens? I am having the same problem and so is another mac user I know. We can't figure it out!

  • Problem Creating an Image Link within an html snippet?

    Hi,
    For some reason I have been unable to link to an image on my Mac by using <img src within an html snippet.
    I have uploaded the photo to my server and created a link with <img src "http://www.domain.com/image.jpg" />.
    However, when I try linking to the image like this - <img src "Users:Documents:Photos:image.jpg" />, when I click apply on the html snippet all I get is a blue dot with a question mark and I have checked that the image is in my Documents and then Photos folder and it is. When I link to it with the server the photo shows.
    Any ideas as to what I am doing wrong?
    I would appreciate some help, as I have tried various combinations to link and nothing seems to be working except linking directly from my server and I don't really want to do this at the moment.
    Thanks

    Thanks for that and I did use correct syntax in the html snippet - it was a typo here.
    I did as you suggested and dragged the photo into the Safari browser, after placing the photo on the desktop and it gave me the file name and that showed as file:///Users/My username/Desktop/Image.jpg, so I tried this in my html snippet and did it as so:
    It is still not working for some reason and when I click apply, the photo shows up as a blue square with a question mark in it, although I know the photo is there.
    Why is this? I followed the path, yet when I link to the photo on the server with it works perfectly everytime.
    Thanks

  • NFirefox will not allow me to click on a link without switching to another program first. The version is 3.6.8. This problem makes Firefox virtually unusable. Help!

    Firefox will not allow me to click on more than one link in a sequence. After one click, I am forced to switch to another active application before returning to Firefox and clicking on another link. I have seen this problem posted by others, but I can't find an answer by Mozilla. Since this problem makes Firefox virtually unusable (version 3.6.8) I would hope that Mozilla would offer an answer ASAP. Until then, I'm stuck with Explorer.
    == This happened ==
    Every time Firefox opened

    Do you have that problem when running in the Firefox SafeMode?
    [http://support.mozilla.com/en-US/kb/Safe+Mode]
    ''Don't select anything right now, just use "Continue in SafeMode."''
    If not, see this:
    [http://support.mozilla.com/en-US/kb/troubleshooting+extensions+and+themes]

  • Problem creating several image maps (linking to different pdf files) RoboHelp 8

    Hi,
    I have a problem creating several image map hotspots (that link to different .pdf files), from the same image using RoboHelp 8 HTML (WebHelp project).
    After compiling, the first image map hotspot created, opens the .pdf file correctly.  Unfortunately, when clicking on the other image hotspots, I get an error " Cannot find file...<file path>... Make sure path or Internet address is correct".
    All the pdf documents are located in the same folder within the project.
    Can anyone help?

    Have you added the target files as baggage?
    See www.grainge.org for RoboHelp and Authoring tips
    @petergrainge

  • Cannot create new virtual network adapter on logical switch team

    I am currently moving from Hyper-V 2012 to Hyper-V 2012 R2 and in turn I have just installed SCVMM 2012 R2. I am using SCVMM 2012 R2 to create some NIC teams which I have done no problem in the past with SCVMM 2012 SP1. Now we have everything set up just
    like we did in the past and it seems to create the NIC team just fine. The problem is when I try to create a New Virtual Network Adapter, when I click the button, it immediately says:
    VMM cannot create the virtual network adapter. Either there are no VM networks associated with the network sites that the uplink port profile "Logical Network Name" Connects to, or the VM networks associated with those network sites all use Hyper-V
    network virtualization.
    Now I've checked and the VM Network is assigned to the logical network that is associated with the Network Site that contains the host I'm working with. I've also tried disabling Hyper-V network virtualization but that didn't change anything and I thought
    that it's always enabled on 2012 R2 anyway.
    I would like to gain network connectivity to this team at least for testing purposes and we also are planning on building a Hyper-V cluster. Were some new restrictions added in 2012 R2 to prevent creating virtual network adapters in this scenario or am I
    doing something wrong?
    Any information would be helpful. Thank you in advance for your time!

    Hi Sir,
    Glad to hear that the problem has been solved , thanks for your sharing .
    Best Regards,
    Elton Ji
    Please remember to mark the replies as answers if they help and unmark them if they provide no help. If you have feedback for TechNet Subscriber Support, contact [email protected] .

  • Problem creating a link to a network folder

    I am working with a SharePoint 2010 site. Due to not being able to utilize SharePoint Designer, I am limited to editing the site by first navigating to the SharePoint site and then selecting edit page from the site options menu.
    I have a table setup and there are two cells within the table that I want to have linked to different network folders. The first cell has 'operations brief' in it, and after researching how to establish a link to a network folder, I learned that I could
    do it by inserting a link and pointing to file://servername. In this situation, I highlighted the text and then selected insert and link from address option. I typed in
    file://Y:\Operations%20Brief\2013 into the URL field. After saving the site, I tested the link and it successfully opened the network folder.
    I then followed the same procedure for another network folder named Quick Reference Card. The only difference between the operations brief folder and the quick reference card folder is that the quick reference card folder has parentheses and numbers - Y:\(8)Library\Quick
    Reference Card (QRC). I am not understanding why when I view the site out of editing mode, I can click on the operations brief folder and have it open. When I click the Quick Reference Card link, nothing happens. The text appears as a hyperlink -- it's in
    blue and is underlined.
    I've removed the link and re-added it several times, only to get the same result. I can't figure out why one link works, and why another one doesn't even though I'm sure I created the second link the same way I created the first link.

    Hi,
    I have followed the same procedure what you followed, it is working as expected and both the links are working fine.  The following is the HTML SOURCE from the content editor web part.  Please verify your HTML source from the content editor part.
    <p>​</p>
    <p>Welcome to Operations folder <a href="file:///Y:/Operations%20Brief/2013">Operations</a></p>
    <p><a href="file:///Y:/(8)Library/Quick%20Reference%20Card%20(QRC)">Quick Reference card folder</a>&#160;</p>
    <p>&#160;</p>
    <p>&#160;</p>
    <p>&#160;</p>
    <p>&#160;</p>
    To view the content editor web part content -> click on Edit Web part -> 
    And also you can try replacing 
    Encoded characters for "(" with %28 and ")" with %29
    http://www.w3schools.com/tags/ref_urlencode.asp
    **Please don't forget to mark as answered and helpful

  • Problem creating virtual Collection

    Hello
    We purchased Windows Server 2012 R2 Datacenter edition and deployed Remote Desktop Services role to it. We created Windows 7 Professional virtual machine using Hyper-V, installed the integration services to it and syspressed it.
    Now we are trying to create a pooled virtual desktop collection, but it always ends with following error messages:
    "Event ID 8216: The virtual hard disk could not be configured. Verify that there are no other virtual hard disks mounted, the virtual desktop template contains a valid Windows operating system image, and the storage for the VHD is available to the RD
    Virtualization Host server. 
    "Event ID 5130: Remote Desktop Virtualization Host could not modify the virtual disk named D:\VRDisk\KGVR\KGVR0\Virtual Hard Disks\KGVR0.vhdx while running a provisioning request for the shared virtual desktop collection named KGVR. Verify that the
    virtual disk has a valid Windows operating system image. Hresult: 0x800703ED"
    What might be the cause for this? I cannot see that there are any virtual hard disks mounted. 
    Best Regards

    Hi,
    From the error description seems that there is some issue with image file and might got corrupt which you have sysprep as can’t working and create your new pooled virtual Desktop. Please check the configuration again and if possible try to create a new image
    syspre it and then create your virtual desktop. You can follow the below guide for more information.
    Test Lab Guide: Managed Pooled Virtual Desktop Collections
    https://technet.microsoft.com/en-in/library/hh831663.aspx
    Hope it helps!
    Thanks.
    Dharmesh Solanki
    Please remember to mark the replies as answers if they help and unmark them if they provide no help. If you have feedback for TechNet Support, contact [email protected]

  • A question about CREATE PUBLIC DATABASE LINK and ORA-12154 error

    Dear all,
    I have a problem about public database link creation and I would appreciate if you could kindly give me a hand. I have the following connection parameters in my
    tnsnames.ora file:
    DGPAPROD.WORLD =
         (DESCRIPTION =
           (ADDRESS_LIST =
            (ADDRESS = (COMMUNITY=tcp.world)
              (PROTOCOL=TCP)(HOST=ORASR001)(PORT=1521)
           (CONNECT_DATA = (SID = DGPAPROD))
    ...Having the above mentioned parameters I can connect to this remote database directly in a SQL*Plus shell:
    $ sqlplus username/[email protected] works pretty well and the connection is established without any problem.
    Now, what I would like to do is to create a public database link to this remote database in order to avoid the user/connection switching for viewing the
    content of this database. I proceeded according to the syntax indicated in the Oracle online documentation:
    http://download.oracle.com/docs/cd/B28359_01/server.111/b28286/statements_5005.htm#SQLRF01205
    Therefore I run the following in order to create a public database link
    CREATE PUBLIC DATABASE LINK SR001_dblink CONNECT TO user IDENTIFIED BY password USING 'DGPAPROD.WORLD';Apparently there is no error and the link is created successfully. However it cannot resolve the remote host and whenever I run the following query
    (myenterprise is the name of a table in that remote database)
    SELECT *
    FROM myenterprise@SR001_dblink
    ERROR at line 1:
    ORA-12154: TNS:could not resolve the connect identifier specifiedWhat causes this problem?
    Thanks in advance,
    Kind Regards,
    Dariyoosh

    spajdy wrote:
    You must have defined DGPAPROD.WORLD in tnsnames.oar on server where you DB is runnig.Hello there,
    Thanks a lot for this nice solution. In fact I had to add the connection parameters into the tnsnames.ora file of the server on which the link was created (not the tnsnames.ora of my oracle client stored on the localhost)
    After a bit googling I found another solution that allows to create the database link:
    CREATE PUBLIC DATABASE LINK SR001_dblink CONNECT TO user IDENTIFIED BY password USING '(DESCRIPTION =  (ADDRESS_LIST =  (ADDRESS = (COMMUNITY=tcp.world)
    (PROTOCOL=TCP)(HOST=ip_adresse)(PORT=1521)))(CONNECT_DATA = (SID = GPAPROD)))';Thanks a lot for your help!
    Kind Regards,
    Dariyoosh
    Edited by: dariyoosh on 18 nov. 2009 07:15

  • Problem with switching tabs in top level navigation for Roles

    Hi,
    I've created two tabs (based on two roles) in the portal top level navigation menu. When clicking the first one it opens as it should. Then when clicking on the second tab it will not open, instead the first tab open up again, it sort of switches back automatically.These  two roles  are  basically consists of worksets and iviews(accessing to r/3).
    Does anyone have any expericene with this type of problem?
    please  suggest me
    Thanks
    Aravinda

    Hi Aravinda
    Please check this link
    Re: Problem with switching tabs in top level navigation
    Regards
    Geogi

  • TE over ospf virtual-link does not work

    Hi Expert,
    I want to practise the TE over ospf virtual-link. The topo is like this one:
    R1 R2
    | |
    R3---R4
    | |
    R5 R6
    all links are in area 0 except link between R3 and R4.
    rt5_1#ro
    router ospf 1
    router-id 1.1.1.1
    log-adjacency-changes
    network 0.0.0.0 255.255.255.255 area 0
    mpls traffic-eng router-id Loopback0
    mpls traffic-eng area 0
    interface Tunnel16
    ip unnumbered Loopback0
    tunnel destination 6.6.6.6
    tunnel mode mpls traffic-eng
    tunnel mpls traffic-eng autoroute announce
    tunnel mpls traffic-eng priority 5 5
    tunnel mpls traffic-eng bandwidth 5
    tunnel mpls traffic-eng path-option 10 dynamic
    rt5_2#ro
    router ospf 1
    router-id 2.2.2.2
    log-adjacency-changes
    network 0.0.0.0 255.255.255.255 area 0
    mpls traffic-eng router-id Loopback0
    mpls traffic-eng area 0
    rt5_3#ro
    router ospf 1
    router-id 3.3.3.3
    log-adjacency-changes
    area 1 virtual-link 4.4.4.4
    network 3.3.3.3 0.0.0.0 area 0
    network 10.10.13.0 0.0.0.255 area 0
    network 10.10.34.0 0.0.0.255 area 1
    network 10.10.35.0 0.0.0.255 area 0
    mpls traffic-eng router-id Loopback0
    mpls traffic-eng area 0
    mpls traffic-eng interface
    Ethernet1/0/1 area 0
    rt5_4#ro
    router ospf 1
    router-id 4.4.4.4
    log-adjacency-changes
    area 1 virtual-link 3.3.3.3
    network 4.4.4.4 0.0.0.0 area 0
    network 10.10.24.0 0.0.0.255 area 0
    network 10.10.34.0 0.0.0.255 area 1
    network 10.10.46.0 0.0.0.255 area 0
    mpls traffic-eng router-id Loopback0
    mpls traffic-eng area 0
    mpls traffic-eng interface Ethernet1/1 area 0
    rt5_5#ro
    router ospf 1
    router-id 5.5.5.5
    log-adjacency-changes
    network 5.5.5.5 0.0.0.0 area 0
    network 10.10.35.0 0.0.0.255 area 0
    mpls traffic-eng router-id Loopback0
    mpls traffic-eng area 0
    rt5_7#ro
    router ospf 1
    router-id 6.6.6.6
    log-adjacency-changes
    network 6.6.6.6 0.0.0.0 area 0
    network 10.10.46.0 0.0.0.255 area 0
    mpls traffic-eng router-id Loopback0
    mpls traffic-eng area 0
    The tunnel 16 on R1 from R6 does not come up .
    rt5_1#sh mpls traffic-eng tunnels t16
    Name: rt5_1_t16 (Tunnel16) Destination: 6.6.6.6
    Status:
    Admin: up Oper: down Path: not valid Signalling: Down
    path option 10, type dynamic
    Config Parameters:
    Bandwidth: 5 kbps (Global) Priority: 5 5 Affinity: 0x0/0xFFFF
    Metric Type: TE (default)
    AutoRoute: enabled LockDown: disabled Loadshare: 5 bw-based
    auto-bw: disabled
    Shortest Unconstrained Path Info:
    Path Weight: UNKNOWN
    Explicit Route: UNKNOWN
    History:
    Tunnel:
    Time since created: 1 hours, 7 minutes
    Path Option 10:
    Last Error: PCALC:: No path to destination, 6.6.6.6
    Does anyone the cause of the problem?
    thanks,

    Hi,
    There is one virutal link between R3 and R4.
    rt5_1#sh mpls traffic-eng topology
    IGP Id: 3.3.3.3, MPLS TE Id:3.3.3.3 Router Node (ospf 1 area 0)
    link[0]: Broadcast, DR: 10.10.35.5, nbr_node_id:24, gen:224
    frag_id 1, Intf Address:10.10.35.3
    TE metric:10, IGP metric:10, attribute flags:0x0
    link[1]: Broadcast, DR: 10.10.13.1, nbr_node_id:25, gen:224
    frag_id 0, Intf Address:10.10.13.3
    TE metric:10, IGP metric:10, attribute flags:0x0
    link[2]: Broadcast, DR: 10.10.34.3, nbr_node_id:-1, gen:224
    frag_id 3, Intf Address:10.10.34.3
    TE metric:10, IGP metric:invalid, attribute flags:0x0
    sh mpls traffic-eng topology brief
    IGP Id: 3.3.3.3, MPLS TE Id:3.3.3.3 Router Node (ospf 1 area 0)
    link[0]: Broadcast, DR: 10.10.35.5, nbr_node_id:31, gen:106
    frag_id 1, Intf Address:10.10.35.3
    TE metric:10, IGP metric:10, attribute flags:0x0
    link[1]: Broadcast, DR: 10.10.13.1, nbr_node_id:32, gen:106
    frag_id 0, Intf Address:10.10.13.3
    TE metric:10, IGP metric:10, attribute flags:0x0
    link[2]: Broadcast, DR: 10.10.34.3, nbr_node_id:-1, gen:106
    frag_id 3, Intf Address:10.10.34.3
    TE metric:10, IGP metric:invalid, attribute flags:0x0
    IGP Id: 4.4.4.4, MPLS TE Id:4.4.4.4 Router Node (ospf 1 area 0)
    link[0]: Broadcast, DR: 10.10.46.6, nbr_node_id:34, gen:104
    frag_id 0, Intf Address:10.10.46.4
    TE metric:10, IGP metric:invalid, attribute flags:0x0
    link[1]: Broadcast, DR: 10.10.24.2, nbr_node_id:19, gen:104
    frag_id 1, Intf Address:10.10.24.4
    TE metric:10, IGP metric:10, attribute flags:0x0
    link[2]: Broadcast, DR: 10.10.34.3, nbr_node_id:-1, gen:104
    frag_id 2, Intf Address:10.10.34.4
    TE metric:10, IGP metric:invalid, attribute flags:0x0
    IGP Id: 5.5.5.5, MPLS TE Id:5.5.5.5 Router Node (ospf 1 area 0)
    link[0]: Broadcast, DR: 10.10.35.5, nbr_node_id:31, gen:94
    thanks,
    guoming

  • Problems Creating PDFs

    A lot of problems creating PDFs come from using the wrong printer to create the PDF or underlying printfile.
    You should use Adobe's Distiller printer instance to create a PDF. This comprises the latest Adobe Postscript printer for your operating system plus the Distiller PPD.
    Don't use an HP printer to create your PDF. PostScript, or otherwise.
    Don't use a Xerox printer to create your PDF. PostScript or otherwise.
    See #1.
    Note: If you are outputting to a service bureau, you might want to use something other than the Distiller printer instance. However, if you encounter problems with your particular PDFs, try using the official method with the Distiller printer to see whether any problems are limited just to your setup. If problems persist, you might have to create your PostScript output using one printer driver and the PDF using Adobe's Distiller printer instance.
    Common problems include:
    Black and white, or greyscale, PDFs created from color FrameMaker books and documents.
    Distiller terminating the PDF creation process early, thus no PDF is created.
    Troubleshooting:
    For lack-of-color problems, first check you don't have Spot as Black set in the Frame Print dialog.
    Update the printer you are using to the latest Adobe PostScript printer driver version.
    Uninstall the printer you are using to create PDFs and to reinstall the latest version from scratch.

    FAQ: Creating PDF Files from FrameMaker Documents -- Why you should not use "save as PDF"! -- Windows & MacOS Only!
    Dov Isaacs - 07:02pm Dec 6, 2001 Pacific
    An issue that has come up over and over again on several FrameMaker and Acrobat/PDF email lists as well on the corresponding Adobe User-to-User forums is that of creation of PDF files. FrameMaker 5.5.6 and 6 have what looks like a convenient feature that is supposed to allow you to create PDF files via simply saving the document as a PDF file. I have gone on record as advising end-users not to use this approach for reliable creation of PDF files from FrameMaker documents under Windows and MacOS with FrameMaker 6 and earlier. Why do I most vociferously offer this advice and why doesn't the problem get fixed? And how SHOULD you create PDF files from FrameMaker?
    GOOD NEWS
    I will start with the good news. The "next major version" of FrameMaker will indeed have "save as PDF" re-implemented in a manner that it will be as reliable as printing to the "Acrobat Distiller" printer instance under Windows or the "Create Adobe PDF" desktop printer under MacOS. I am personally working with the FrameMaker development organization to make sure this really happens and is fully and properly tested and debugged! Furthermore, this next major revision of FrameMaker, unlike FrameMaker 6, will come with a Distiller installer that will properly install the "Acrobat Distiller" printer instance under Windows and the "Create Adobe PDF" desktop printer on the Macintosh (of course assuring that the latest PostScript driver is also automatically and correctly installed).
    DON'T USE "SAVE AS PDF"
    But what's wrong with "save as PDF" as currently implemented?
    The following are some of the SYMPTOMS reported over the last few years by FrameMaker users that were traced back to use of "save as PDF" under FrameMaker:
    (1) No PDF file is produced at all, possibly with a log file showing not-readily apparent PostScript errors during distillation.
    (2) The PDF file "loses" color in images. All or some images (raster, bitmap images, NOT vector artwork) appear in the PDF file in grayscale.
    (3) The resultant PDF file is on the wrong paper size, i.e., the document's logical page size does not match the output page size as seen in Acrobat or Acrobat Reader.
    (4) Some or all text in the resultant PDF file is blotchy looking or overly bold.
    (5) Some or all text in the resultant PDF file cannot be searched or indexed.
    (6) Some or all text in the resultant PDF file appears in Courier or in some other substitution font.
    (7) Interword or intercharacter spacing is a bit irregular in the resultant PDF file.
    (8) Content is missing in the margin areas of the page, i.e. you cannot do full-page bleeds.
    (9) Some or all page content is missing (other than margin areas).
    (10) Relatively inefficient PDF is generated.
    If this list by itself isn't enough for you, please note that some of these symptoms are very subtle and may escape attention when the PDF is first viewed or printed. Oftimes, it is when one attempts to manipulate the PDF file in Acrobat or repurpose its content or even view or print on a system other than the one on which the PDF file was created, that some of these symptoms make themselves obnoxiously visible (or invisible in some cases I won't make any bad jokes here about graphic examples!).
    It is important to understand that FrameMaker does NOT have its own native ability to create PDF. Any and all PDF created from FrameMaker documents is actually done by creating PostScript via the PostScript driver and having the Acrobat Distiller create PDF from that PostScript. The only exception to this is creation of PDF via the Acrobat PDFWriter driver, which is likewise not recommended (see below).
    In order for "save as PDF" to work correctly, FrameMaker must do the equivalent of calling Printer Setup and selecting the "Acrobat Distiller" printer instance under Windows or the "Create Adobe PDF" desktop printer under MacOS followed by setting the driver's options correctly for paper size, page range, etc., followed by sending the proper commands to the driver to create PostScript.
    Contrary to popular belief, PostScript as generated by the Windows and MacOS PostScript drivers is VERY device-dependent. The information in the PPD file associated with a printer driver instance provides critical parameters for generation of PostScript including:
    Whether the printer supports color (Acrobat Distiller does)
    What PostScript language level is supported (Acrobat Distiller 4.x and Acrobat Distiller 5.x are both PostScript language level 3)
    Whether native TrueType support is available (Acrobat supports native TrueType as Type 42 fonts)
    Available binary communications (Acrobat Distiller supports pure binary and ASCII, but NOT TCP, TBCP, or PJL)
    Resident fonts (Acrobat Distiller doesn't really have resident fonts)
    Available paper sizes and custom paper size availability (Acrobat Distiller supports a wide range of predefined sizes and continually variable "custom" sizes up to 200" by 200")
    Margins / printable areas (for PDF and the Acrobat Distiller, there are no margins in which imaging is not permitted)
    Device resolution (Acrobat Distiller can be set to any value from 72 to 4000 dpi; as a convenience, the Acrobat Distiller PPD provides a series of values for use by the driver. Since there is no inherent "resolution" of a PDF file, this parameter is used only for purposes of allowing PostScript programs that query for such a value to be satisfied and for the driver to be able to communicate this value to the operating system and/or application as required.)
    Paper handling (totally irrelevant to Acrobat Distiller if input or output tray selection via "setpagedevice" is found in the PostScript stream, it is ignored by Acrobat Distiller)
    Thus, if the wrong printer driver instance is selected (i.e., it isn't associated with the Acrobat Distiller PPD file) or that driver instance is improperly configured, improper PostScript will result and one or more of the symptoms described above can occur. As currently implemented, FrameMaker depending upon version will not necessarily choose the correct printer driver instance and/or correctly parameterize the print job via driver setup options. In fact, FrameMaker 5,5,6 might even try to generate PDF via calling a PCL driver, FAX driver, or even a non-PostScript inkjet printer!
    DON'T USE PDFWRITER
    The Acrobat PDFWriter is a relic of older versions of Acrobat. In fact, it is no longer installed by default in the "easy install" or the "typical install" of Acrobat 5. It hasn't really be updated since Acrobat 3 and only supports PDF 1.2. It is a GDI (Windows) / QuickDraw (MacOS) driver that directly generates PDF without any intermediary PostScript. Since it is not a PostScript printer driver, applications cannot pass through EPS graphics and/or PDFMark information (used for a wide variety of purposes by FrameMaker). For EPS graphics, most applications will send the low resolution TIFF (or PICT) EPS header in lieu of the PostScript text, if they send anything at all, to the driver. Forget about links, structure, or any other PDF "goodies." Expect that PDFWriter will fully "bite the dust" in the next major version of Acrobat.
    SO HOW DO I GENERATE PDF FILES FROM FRAMEMAKER 6 & EARLIER?
    The ONLY method that is really reliable for producing PDF files with FrameMaker 6 and earlier requires the generation of PostScript via a properly set printer driver instance associated with the Acrobat Distiller PPD and distillation of the resultant PostScript by Acrobat Distiller.
    Case 1: FrameMaker and the Full Acrobat 4.05 or Acrobat 5.0x Products
    PDF file from a "chapter" -- print directly to the Acrobat Distiller printer instance (Windows) or the Create Adobe PDF desktop printer (MacOS) already installed by Acrobat. If you check the "Acrobat data" option, then make sure to UNcheck the "print to file" option that gets set at the same time. As a result, the driver will automatically send the generated PostScript to the Distiller for you and delete the intermediate PostScript when done.
    PDF file from a "book" -- print directly to the Acrobat Distiller printer instance with the "print to file" option checked (Windows) or the Virtual Printer desktop printer (MacOS) associated with the Distiller PPD (see details below under Case 2/MacOS). You will need to manually process the resultant PostScript file through the Distiller (or use a "watched folder" arrangement).
    In both the above sub-cases, the default driver options generally will be OK, but check on paper size and communication protocol (Use pure binary, not ASCII, for optimal performance AND no CTRL-D characters under Windows. Make sure to set Level 3 only and Binary under MacOS. Font inclusion "All" for Acrobat 4.05 and "None" for Acrobat 5 under MacOS.). With Acrobat 4.05, make sure you preset the Distiller to use the joboptions you want. With Acrobat 5, you can set this on a job-by-job basis via the driver printer setup interface (or print dialog on MacOS).
    Case 2: FrameMaker 6 and the Bundled Acrobat 4.05 Distiller
    Windows -- Create a new printer driver instance using the latest version of the Adobe Universal PostScript Driver Installer, downloadable from Adobe's web site AND the Acrobat Distiller PPD file (located in the XTRAS subdirectory of the Distiller directory). This driver instance should be set to print to the local port named "FILE:". Name this driver instance as "Acrobat Distiller". The default driver options generally will be OK, but check on paper size and communication protocol (use pure binary, not ASCII, for optimal performance AND no CTRL-D characters). Make sure you preset the Distiller to use the joboptions you want. Print directly to this Acrobat Distiller printer instance. Make sure that the "print to file" option is checked. You will need to manually process the resultant PostScript file through the Distiller (or use a "watched folder" arrangement).
    MacOS -- Install the latest version of AdobePS 8.7.x, downloadable from Adobe's web site. In FrameMaker, go to Page Setup and select the "Virtual Printer" and go to the "Virtual Printer" window pane. Select the Acrobat Distiller PPD file (located in the XTRAS subfolder of the Distiller folder). Print directly to the "Virtual Printer" (Make sure to set Level 3 only, Binary, and font inclusion "All".). Make sure you preset the Distiller to use the joboptions you want. You will need to manually process the resultant PostScript file through the Distiller (or use a "watched folder" arrangement).
    Case 3: Acrobat 3
    Acrobat 3 is not officially supported for the latest OS versions and I personally would no longer recommend its use for generation of PDF files given that Acrobat 5.0.5 is the current version of Acrobat.
    - Dov

  • Problem Creating Hyperlink to another workbook

    I am having a problem creating a hyperlink to a worksheet in another workbook.
    Here is what I have done:
    Created the master and detail reports in 2 different workbooks.
    Executed the master worksheet to display the data
    Right clicked the field in the first row where I want to create the hyperlink, and chose Manage Links
    Clicked the New Link button
    Chose Worksheet for Where do you want to link to?
    Clicked Browse by the Destination Worksheet
    Clicked the detail report from the list of workbooks but the select button is grayed out
    Does anyone have any idea why it won't let me select the detail report to link to?
    I have OracleBI Discoverer Plus 10g
    Any suggestions would be deeply appreciated.

    Yes, I did add a parameter to the detail report so that I could get detail just for that one item. The part that is giving me trouble is specifying the Destination workbook/worksheet. I see the detail report when I browse but the Select button is grayed out so I haven't made it to the part where you identify what values to pass to the detail report yet.

Maybe you are looking for

  • How can i load Client side XML file to Table

    Hi, How can i load the all the XML files (near 10,000 files) available in client machine to the XML table . I did try with directrory list in the Webutility demo form, but when the number of file is near to 1,500 its giving error. Please suggest the

  • Photo are not showing in view area when looking in folder for picture

    When i have a photo folder open the pictures are not showing where i can see them without having to open the file, they used to after i updated my touch smart the photo are is gone

  • When try to install on windows: Error 1330: cabinet file data1.cab invalid

    I'm trying to install Java 6 build 13 on a windows XP computer. It gives me the error: Error 1330: A file that is required cannot be installed because the cabinet file "C:\...\Data1.cab" has an invalid signature. This may indicate that the cabinet fi

  • Safari Crashes on Startup

    Safari started crashing all the time each time it starts. I think a Java update was installed and the safari problem. Started Macbook Pro in safe mode and disabled extensions but Safari still crashes. I am running OSX Mavericks on MacBook Pro 2011. A

  • Wrongly selected landline instead of mobile number...

    i mistakenly selected landline instead of mobile kindly help me to cancel the present subscription or change my present subscription to mobile number