Problem in 0581 infotype

when i am maintaining infotype 0581 and giving the amount , the system is giving the message "No automatic updation 0008, allowance grouping not found"
rgrds
sw

Hi Shweta,
Check for the allowance grouping of the employee (based on the PS type, PS group, PS area, PS level and ESG fpr CAP) and check if a wage type exist in V_TINA9 for the allowance grouping of the employee.
Regards,
Praveen

Similar Messages

  • Display Problem in Custom Infotype

    Hello Experts,
                          A problem is being encountered in the display of data using the overview icon for a custom infotype. When we enter data through transaction PA30, we are able to see data as per the date validities when the user clicks on display icon. But when the Overview button is clicked, the data is not being displayed properly.
    The following comments were logged with the following dates.
    02.12.2007 31.12.9999 - Comment 1
    14.11.2006 30.11.2006 - Comment 2
    01.01.2006 13.11.2006 - Comment 3.
    when the same is observed using Overview icon, data is not being diaplyed properly.
    Any help would be greatly appreciated.
    Thanks
    Srinivas.

    Hi Sankhadip,
                           Thanks for your reply. The problem is in my Custom IT9005. The time constraint of the infotype is 2. I am using LSMW to upload data. I am not having any problem with loading data as of now, but its only wit the overview icon, its not updating properly.. Please help me with this. Thanks again for your response.
    Srinivas.

  • Problem with LSMW infotype 1950 recording

    Hi !
    When I use The LSMW recording facility to play in a PO10 Properties (HR infotype 1950) I get error in the process step when the pgm action to the =UPD command  is to clear all the screens fields (pgm MP195000 screen 2000).
    I see that when LSMW process step is running sets sy-datar to "X" when MP195000 screen 2000 is executing and then a clear step executes
    ....but it do not be the same with manually infotyp input  by the same screens.
    Can some one help me  with this problem?

    Can I import it from the QA Client....there are lot of recording in this project , in which I just want to export/import only one project , how can I do that .

  • Problem in custom infotype module pool

    Hi experts,
    I have created custom infotype using PM01 where i am showing fields Basic and HRA. When I enter the value for Basic, automatically the calculation for HRa should be done depending on formula. Also, the HRA fields should be only output field. When I do the changes in the module pool PBO and regenerate the object , the changes I made get disappered. Do I have to create Z of the includes. If so, how to assign it to the infotype?  Please help me to solve this problem since its urgent.
    Thanks in advance.
    Proper solution would be rewarded.
    Ujjwala

    C
    This is the flavour of Infotype.
    When you regenerate the Infotype, you are again reassigning the Chanrecterstcis of your Infotype. so the Existing will get regenerated with the Standard Code.
    To avoid this what I suggest you is.
    After finishing the Regeneration then edit the Module pool of the Infotype basically Screen 200 then add your code and Activate it there itself. Hope you got it.
    If you again Regenerate it you loose your Code.
    If you have further Questions please let me know.

  • Problem inserting in Infotype 0002 using FM HR_INFOTYPE_OPERATION

    Hello.
    Im having some trouble uploading data to the PA0002 infotype table. In my program , I upload all the information from a txt file. In this file, every line correponds to an entry of the table.
    To do this, I use the SPLIT sentence to insert in a pa0002 structure, all the values that come from the file line. After that, I use the HR_INFOTYPE_OPERATION to insert the data.
    This works for almost all the tests i made, except for one case: when I have to pass the P0002-ANZKD (number of children) field to the FM.
    The problem here is that when I call the function module the value seems to be correct. But when I make a debug  inside the FM, i noticed that this value is not displayed correctly when the FM makes the move operation to insert this value in the corresponding FVAL field for the PROPOSED_VALUES table. Also, all the values going after this field are not represented correctly in the PROPOSED_VALUES table.
    P0002-ANZKD is a DEC type field, so to make it work with SPLIT, i had to specify ANZKD as a type c field in my structure (everything else is as equal as P0002).  And I also tried uploading the data, first to my structure and later I make a MOVE-CORRESPONDING to an exact P0002 structure, but I get the same result in this case too .
    Does anybody now how can solve this issue?
    Thanks in advance,
    Juanma.

    Hi,
    I've managed to solve the problem. Changing the size of the anzkd field of my structure (greather than 3) and then passing all the values to a  p0002 stucture,  gave me the opportunity to upload succesfully the data into pa0002 with the FM.
    Thank you for your help Anil,
    Juanma.

  • Problem in custom infotype.

    Hi friends,
    I have two problem on creating custom infotype 9010.
    The infotype has 4 field:
    docu_type -> subtype field
    Docu_number
    cost -> DE:WAERS
    cost_curr -> DT: Curr length 10 dec 2
    I referred the cost to the cost_curr field of the infotype 9010
    First Problem
    The infotype is created but when I tried to enter the cost via pa30
    put 50 on it, and press enter, 50 will be changed into 5000. But when I re-enter again, the ammount remained unchanged.
    2nd Problem.
    For the infotype i need to give a further information on the screen.
    Such as that, it looks like the screen on IT0022 where when you put the educational establishment, the text of the subtype appears beside it. How do I suppose to do things like that with my infotype so that when I enter 4 as the subtype field, the subtype text appears.
    Thanks

    prob 1 .
    what is the reference field u have given for the currency of ur 9010 table .. just check the reference field u have given for currency ..
    how are u handling this in the pai part of the code , can u just make the field pass to a char field and then reassign it to the screen field .. for primary investigation.
    prob 2.
    u need to maintain a field just adjacent field in the layout as ouput field only . and populate this field with the suitable text once u enter the subtype field which is input field .
    this u need to do in the pai part of the infotype mp901000 code  ..
    if p-styp is not initial .. "subtype is present fire the text part .
    populate text to screen field p9010-stxt.
    endif.

  • Problem in custom infotype --urgent

    Dear Freinds,
                i have create a custom infotype , iam facing one problem when i say
    create and enter into the screen, and if the user doesnt do any change any thing
    in the screen (i.e if he is not performing any changes in the screen) and hits
    the button back , it is asking do  you want to save.  Please let me know why it is  behaving in this way.
    regards
    syamala.

    Dear Pranesh
                 i have created the custom infotype..........while testing i have found that
    if i am creating a new record and we dont select any record in the infotype
    and try to exit (by clicking X button) then a popup button is coming for a confirmation do you want to save the record.......here i have not select any field
    after me pressing F5 (create) in PA30 . So now if  say yes it saves record , if no
    then it exists out of infotype without saving............this should not come like this
    please let me know what i should do in this regard.
    however--- if  enter begda and endda  it is saving on the dates i have entered...so it will be new record only...........it gets delimited ...as begda and endda or not defaulted.
    thanks in advance

  • Problem creating PD infotype

    Initially I tried creating PD infotype by creating the structure HRI9005 and then going to PPCI to create custom infotype. Due to some reason , I had to delete all objects from the requests . When I tried to create it the next time , it is throwing me error messages as Structure p9005 does not exist, table hrp9005 does not exist . Is it something to do with my previous deletions . Any suggesions to overcome this problem would be highly appreciated

    use this link:
    http://help.sap.com/saphelp_erp2005/helpdata/de/b7/0feb34bf03c210e10000009b38f83b/frameset.htm

  • Problem in updating infotype 2001

    Hi Experts,
                     While i am  updating infotype 2001 , using HR_INFOTYPE_operation FM it giving a error , because it calling a wrong sceen 2000 , instead of 2001 . can anybody can help on this ?
    thanks and regards
    Renjith MP

    Hi Dude,
    Go through the below code for 2002 infotype :
    TYPES BEGIN OF text_version.
    TYPES   nummer TYPE x.
    TYPES END OF text_version.
    DATA: PERSONALDATAKEY    LIKE BAPIPAKEY.
    DATA: RETURN       LIKE BAPIRETURN1.
    DATA: P2002       LIKE P2002.
    DATA: PSKEY       TYPE PSKEY.
    DATA: IT_TEXT       TYPE HRPAD_TEXT_TAB .
    DATA: LINE       TYPE HRPAD_TEXT.
    DATA: version       TYPE text_version.
    DATA: pcl1       TYPE pcl1.Input Parameters:
    PARAMETERS:  PERNR  LIKE PA2002-PERNR  DEFAULT '1004511',
                 AWART  LIKE PA2002-AWART  DEFAULT 'LW',
                 BEGDA  LIKE PA2002-BEGDA  DEFAULT SY-DATUM,
                 ENDDA  LIKE PA2002-ENDDA  DEFAULT SY-DATUM,
                 BEGUZ  LIKE PA2002-BEGUZ,
                 ENDUZ  LIKE PA2002-ENDUZ.
    START-OF-SELECTION.
      CALL FUNCTION 'HR_EMPLOYEE_ENQUEUE'
            EXPORTING
              number = PERNR
            IMPORTING
              RETURN = RETURN.
      IF RETURN-NUMBER IS NOT INITIAL.
        EXIT.
      ENDIF.
    * ADD DATA
      CLEAR: P2002.
      P2002-PERNR = PERNR.
      P2002-SUBTY = AWART.
      P2002-ENDDA = BEGDA.
      P2002-BEGDA = BEGDA.
      P2002-BEGUZ = BEGUZ.
      P2002-ENDUZ = ENDUZ.
      P2002-AWART = AWART.
      P2002-ITXEX = 'X'.
    * WRITE DATA
      CLEAR: RETURN, PERSONALDATAKEY.
      CALL FUNCTION 'HR_INFOTYPE_OPERATION'
             EXPORTING
                  INFTY          = '2002'
                  NUMBER         = PERNR
                  SUBTYPE        = AWART
                  VALIDITYEND    = BEGDA
                  VALIDITYBEGIN  = BEGDA
                  RECORD         = P2002
                  OPERATION      = 'INS'
                  NOCOMMIT       = ''
                  TCLAS          = 'A'
             IMPORTING
                  RETURN         = RETURN
                  KEY            = PERSONALDATAKEY
             EXCEPTIONS
                  OTHERS         = 0.
      IF RETURN-NUMBER IS INITIAL.
        COMMIT WORK AND WAIT.
      ELSE.
        ROLLBACK WORK.
        EXIT.
      ENDIF.

  • Problem During maintaining Infotype 8 in tcode PA30

    hi all,
    i have different PS group for employees like OFFICER and EXECUTIVE and when i m creating the IT 8 then i select group as OFFICER and then it pics the wage type '1001', '1004', '1013' and '1016' automaticaly but problem is that when i select group as EXECUTIVE then it pics nothing automatically.
    can anyone please tell me what is the prob and how can i remove it?
    Regards.

    in PSG  and PSL
    thre is mismatch of Groupings Check with Archanas response once
    Check the Groupings of ur PSG  PSL and ur allowance Grouping

  • Updation problem in custom infotypes.

    HI ALL,
    I have created two custom infotypes, and the process is that one infotype updates the other infotype.
    When i open the first infotype by pa30 and then open the second and changes some value which update the first infotype table. now when i go to first info type it shows the old value. untill i exit pa30 and start again then it shows the updated values. what is the solution for this.
    Thanks.

    Hi abap sap,
      It is becasue of PAI and PBO module itterations.
    Go to the custom related program created with that infotype and insert your logic to clear the field contents.
    Reward if useful!

  • PPCI - Problem in Creating Infotype

    Hello Expert,
    I want to create OM custom infotype,but in T.code - PPCI afte entering necessary entries when clicked on Create m getting follwing log .Please let me know whether i am doing any mistake :
    Infotype 9501
           Dictionary
               Structure HRI9501 exists
               Structure P9501 exists
               Table HRP9501 does not exist
                   HRP9501 not created in the database
                   Database index XXXX not created
           Module Pool
               Module pool MP950100 does not exist
               Include MP950120 does not exist
               Include MP9501BI does not exist
           Screens
               Screen 1000 does not exist
               Screen 2000 does not exist
               Screen 3000 does not exist
           User interface
               User interface for MP950100 does not exis
           Table entries
               T778T: no table entries exist
               T777T: no table entries exist
               T777D: no table entries exist
               T77ID: no table entries exist
               T777I: no table entries exist
               T777Z: no table entries exist
               T77OA: no table entries exist

    Hi,
    Before calling transaction PPCI you need to create the HRC9XXX structure via SE11.
    Then you can carry on to PPCI - Create.
    When you have the log of tables to be maintained, please make sure you have updated the tables T777I, T777D, T770A
    Regards,
    Dilek

  • Problem with OM infotype

    Hello,
    I have a problema with the IT1222 (General Attribute Maint.) in OM (Po10). I have configured it in SPRO with a new sutype (9104) and this subtype with 2 attributes in the table T77OMATTR.
    Well, all is working, but I need that those attributes gets inherited to the objects (organizational units) that has a relationship in a lower level to the main organizational unit.
    Thanks,

    Thanks all, I have solved it.

  • Problem updating the infotype 1208 subtype ALUM

    Hi,
    My requirement is to update the infotype 1208 subtype ALUM with the Value "YES" when I terminate a employee in PA40. ( immediately).
    I am using the FM - HR_INFOTYPE_OPERATION which doesn't seem to work.
    I tried running a BDC for PA30 , but it is not allowing me to edit the employee and says that i am processing him.
    I feel this is an issue with locks. But not sure about how to go with.
    Are there any standard classes available or any other method to use to update this infotype while terminating.
    Regards,
    Karan.

    Hi,
    try using this method, this will convert the OLD_IMAGE, NEW_IMAGE, parameters into pnnnn table.
    this code is the following class.
    CL_IM_BR_SALARY_INCREASE,
    you need to create your own method, copy the parameters as well.
    method READ_IMAGE .
      FIELD-SYMBOLS: <f> type any.
      DATA: help_prelp TYPE prelp,
            inf_tabname(10).
      data: wa_p0008      type p0008,
            wa_p0734      type p0734.
      concatenate 'WA_P' p_infty into inf_tabname.
      ASSIGN (inf_tabname) TO <f>.
      loop at p_image into  help_prelp
                      where infty eq p_infty and
                            opera eq p_opera and
                            subty eq '0'.
        CLEAR <f>.
        CALL METHOD cl_hr_pnnnn_type_cast=>prelp_to_pnnnn
          EXPORTING
            prelp = help_prelp
          IMPORTING
            pnnnn = <f>.
          append <f> to pnnnn.
      endloop.
    endmethod.
    Message was edited by:
            javier  santana

  • Problem in customize infotype data for save

    Hi experts,
    specially for ABAP-hr guys.....Can u pls help me in providing me the correct solution for the below:
    I had created the new infotype with table control now i have to save this table control value means list box value or check box value which is been inside the table control.How i save these values in the table .
    Shall I have to write the query for Insert the data in infotype or some other way.Because if i take the only fields in the infotype insted of table control no need to write the query statement.
    How can i achive this pls help me.
    Thanks
    sandeep

    Hi,
    Just remember one thing never ever fire any SQL query (Inset,Delete,Update) on infotypes it can cause havoc.
    to maintain infotypes SAP has given few standard function modules. use HR-INFOTYPE-OPERATION to maintain infotype data.
    you can also use BDCs  and LSMWs to upload data as well but never a quey unless if u dnt have ne other options and u knw exact impacts of the same.

Maybe you are looking for

  • Help Please! Syncing from my ipod touch

    I've connected my ipod to my computer as per and it's synced all the purchases i've made on my ipod to my computer, but just at the end it gives an error message and lo and behold i've lost about 1000 songs. Not sure where, or which ones, but my numb

  • How to install the sample shema (HR)

    Hi, I'm begining to study the class about the introduction to PL/SQL and I need the shema HR for it. But I lost it during a 'cleaning' of my PC to retrieve some place. So I created a new database named 'HR' and I tried to run the hr_* scripts that I

  • [SOLVED] Update to Samba 4 completely broke functionality of Samba

    I have a computer running Arch 64bit, from which I share media files to my girlfriend's Windows 7 laptop, and to my own Windows 8 tablet. Until an hour or so, I was running Samba 3.6.13 which happily worked most of the time (with occasional breaks th

  • How to diable only one field enabled and other fields disabled for one user group?

    Hi, I have a form contains many fields. A group of users can add items using that form. As per the user requirement I have created a filtered view and that filtered view can be seen by some other sharepoint user group but as per their further require

  • Shortcut for selecting non-default button in dialog boxes

    I seem to remember that there was a keyboard shortcut many OSs ago. I can't seem to find it or replicate it. Particularly, I would like to choose the non-default button in a dialog box in Acrobat Pro for productivity's sake. Thanks, Jon