Problem with deploying FPGA host VIs using TestStand deployment utility

I am using a PCI-7831R FPGA to control an automated test fixture.  I have several host VI's that I am calling from TestStand (4.2.1) in order to control the 7831R.  The host VI's that TestStand calls are setup as sub-VI's and are used for various things such as opening an FPGA reference (which is bound to a strict type def), downloading and executing the files on the 7831R, reading writing to controls, and finally closing the reference.  In the sequence file, I am passing the reference values as a file global so that the host sub-VI's can communicate correctly.  I have all functionality working correctly in TestStand on my development PC.  When I go to deploy this to a production PC, I get errors when the sequence file trys to load the first host VI.  The error basically states that the VI is broken - try to open and run it (which I can't because I have no development license on the production PC).  I am currently trying to deploy this to another development PC to see if I can track down where the VI might be breaking. 
I have included the lvbitx and strict type def control that the host subVI's reference in my deployment files.  I can't think of anything that I might be missing.  Is there any good documentation on exactly which files I need to include in the deployment when using FPGA Host VIs (the TestStand reference manual is pretty vague at best)?  It seems that any documentation that I read says the TestStand deployment utility will analyze all VI dependencies (other than shared variables).  On a side question, is the strict type def considered a shared variable?
Has anyone successfully deployed a sequence that calls host VI's?  Any help would be greatly appreciated.  If any of the above needs further clarification please ask away and I will be happy to give more details. 
Thanks,
Mike

Hi hawkstringer
Do you encounter this problem using a deployed version of your code? Note that the subject of this topic is about deploying an FPGA application.
I forgot I posted here, in the mean time I've managed to deploy my application. I think my problem was solved when I included all necessary drivers and components (but I'm not absolutely sure). I included the following:
NI IVI Compliance Package
NI FlexRIO
NI PXI Platform Services Configuration Support
NI R Series Multifunction RIO
NI DAQmx Core Runtime
NI DAQmx MAX Configuration Support
NI RIO
Good luck!

Similar Messages

  • Problem with flash on IE11 after using adobe cleaner

    Problem with flash on IE11 after using adobe cleaner to remove a trial version of photoshop because there was not any entry on add/remove applications in windows 8.1
    Its to frustrating to reinstall everything. I tried everything from your support page with no luck…

    Link for Download & Install & Setup & Activation problems may help
    -Online Chat http://www.adobe.com/support/download-install/supportinfo/

  • Problem with Adobe Premiere Elements 12 using Scary Halloween template

    I'm having a problem with Adobe Premiere Elements 12 using Scary Halloween template under Menu Theme.  My problem is the red line is default to Scenes.  I would like it to default to Play.  How can I do that? Is it a bug?
    Side Note:  Other template default to Play Movie
    Thanks

    jeffrey caban
    No bug. Just the way the .psd for the Scary Halloween template was put together.
    You are going to have to get into the .psd for the Scary Halloween template and rearrange the
    Layer Sets. Do you know how to do that? If not, I will give you very specific instructions on how to
    do that.
    You want the order of the Layer Sets to look like
    That is what worked for me just now to get the disc menu Preview to open to the main
    menu with the red highlight under Play.
    We will be watching for your reply.
    ATR

  • I have a problem with iphone4 I bought a used and unlocked iphone4 old apple id because the first owner dies please help me how to activate iphone4 I unlocked with icloud

    I have a problem with iphone4
    I bought a used and unlocked iphone4
    old apple id because the first owner dies
    please help me how to activate iphone4
    I unlocked with icloud

    fherly nur arief wrote:
    I unlocked with icloud
    If you had already removed the device from 'Find My iPhone' in iCloud, then you jus tneed to powercycle the device in order to activate it.
    Source: http://support.apple.com/kb/TS4515
    "After the device is removed from the previous owner’s account, turn the device off by pressing and holding the Sleep/Wake button located on the top-right side of the device. Then restart your device and proceed with device setup as you would normally."
    If it has not been removed, then the activation lock is still active.
    If the previous owner cannot remove the device from their account there is nothing you can do unless the place you purchased it from will give you a refund.
    Activation Lock: http://support.apple.com/kb/ht5818
    What if I purchase a device that is still linked to the previous owner's account?
    Contact the previous owner as soon as possible and ask them to erase the device and remove it from their account. For complete instructions, read how to remove a device from a previous owner's account.
    How do I check for Activation Lock before purchasing a used device?
    When purchasing an iPhone, iPad, or iPod touch from someone other than Apple or an authorized Apple reseller, it is up to you to ensure that the device has been erased and is no longer linked to the previous owner’s account.
    Follow each of these steps to make sure that you can use the device you purchase:
    Turn the device on and slide to unlock.If the passcode lock screen or the home screen appears, the device has not been erased. Ask the seller to completely erase the device by going to Settings > General > Reset > Erase All Content and Settings. Do not take ownership of any used iPhone, iPad, or iPod touch until it has been erased.
    Begin the device setup process.After choosing a language, choosing a country, and connecting to a network, the device will begin activation. If you are asked for the previous owner’s Apple ID and password, the device is still linked to their account. Hand the device back to the seller and ask them to enter their password. If the previous owner is not present, they can remove the device from their account by signing in to icloud.com/find. Do not take ownership of any used iPhone, iPad, or iPod touch until it has been removed from the previous owner’s account.
    You will know that a device is ready for you to use when you are asked to “Set up your iPhone", “Set up your iPad", or “Set up your iPod” during the device setup process.

  • I have the new iPad. Even with airplane mode on, my battery life is extremely limited. Is there a problem with the battery? I used to have the ipad2 and had no such problem.

    I have the new iPad. Even with airplane mode on, my battery life is extremely limited. Is there a problem with the battery? I used to have the ipad2 and had no such problem.

    What is your brightness setting & how many apps are open?
    The quickest way (and really the only way) to charge your iPad is with the included 10W USB Power Adapter. iPad will also charge, although more slowly, when attached to a computer with a high-power USB port (many recent Mac computers) or with an iPhone Power Adapter (5W). When attached to a computer via a standard USB port (most PCs or older Mac computers) iPad will charge very slowly (but iPad indicates not charging). Make sure your computer is on while charging iPad via USB. If iPad is connected to a computer that’s turned off or is in sleep or standby mode, the iPad battery will continue to drain.
    Apple recommends that once a month you let the iPad fully discharge & then recharge to 100%.
    How to Calibrate Your Mac, iPhone, or iPad Battery
    http://www.macblend.com/how-to-calibrate-your-mac-iphone-or-ipad-battery/
    At this link http://www.tomshardware.com/reviews/galaxy-tab-android-tablet,3014-11.html , tests show that the iPad 2 battery (25 watt-hours) will charge to 90% in 3 hours 1 minute. It will charge to 100% in 4 hours 2 minutes. The new iPad has a larger capacity battery (42 watt-hours), so using the 10W charger will obviously take longer. If you are using your iPad while charging, it will take even longer. It's best to turn your new iPad OFF and charge over night. Also look at The iPad's charging challenge explained http://www.macworld.com/article/1150356/ipadcharging.html
    Also, if you have a 3rd generation iPad, look at
    Apple: iPad Battery Nothing to Get Charged Up About
    http://allthingsd.com/20120327/apple-ipad-battery-nothing-to-get-charged-up-abou t/
    Apple Explains New iPad's Continued Charging Beyond 100% Battery Level
    http://www.macrumors.com/2012/03/27/apple-explains-new-ipads-continued-charging- beyond-100-battery-level/
    New iPad Takes Much Longer to Charge Than iPad 2
    http://www.iphonehacks.com/2012/03/new-ipad-takes-much-longer-to-charge-than-ipa d-2.html
    Apple Batteries - iPad http://www.apple.com/batteries/ipad.html
    Extend iPad Battery Life (Look at pjl123 comment)
    https://discussions.apple.com/thread/3921324?tstart=30
    New iPad Slow to Recharge, Barely Charges During Use
    http://www.pcworld.com/article/252326/new_ipad_slow_to_recharge_barely_charges_d uring_use.html
    Tips About Charging for New iPad 3
    http://goodscool-electronics.blogspot.com/2012/04/tips-about-charging-for-new-ip ad-3.html
    Prolong battery lifespan for iPad / iPad 2 / iPad 3: charging tips
    http://thehowto.wikidot.com/prolong-battery-lifespan-for-ipad
    In rare instances when using the Camera Connection Kit, you may notice that iPad does not charge after using the Camera Connection Kit. Disconnecting and reconnecting the iPad from the charger will resolve this issue.
     Cheers, Tom

  • We encountered a problem with some client machines that use Firefox version 24ESR and IE8. Ajax requests of aspx pages from Firefox are getting the following er

    I encountered a problem with some client machines that use Firefox version 24ESR and IE8.
    Ajax requests of aspx pages from Firefox are getting the following error from the iis server (iis version 7.5):
    Bad Request - Request Too Long
    HTTP Error 400. The size of the request headers is too long.
    From analyzing the request that was sent to the server, I saw that the request consist of only the viewstate of the aspx page.
    I tried to disable the viewstate for one page and the server got the request correctly.
    I do not encounter any issues on these laptops with postback requests from Firefox or when running the same application with IE8.

    Sometimes that means that the page address sent is loo long.
    Check the link address you are using.
    I can't help you further and will send for more help.

  • Problem With MC.1 Report vis-a-vis chnage in Division

    Dear All,
    I am facing some problem related with MC.1 Report.
    The problem is basically due to Change in DIVISION field after doing MIGO.
    At the time of Material upload, wrong Division was uploaded. While analyzing the MC.1 report basis the Division, we came to know that the Report is wrong due to wrong Division in Material Master.
    We rectified the Division, ran the MC.1 report, we found that the Stock is getting displayed in both the (old & new) Divisions based on the Transaction date.
    Would like to know is there any method thru which we can update the Old Transactional Records (related with Division) so that we can get the correct report.
    Thanks & Regards,
    P K Karn

    Hi hawkstringer
    Do you encounter this problem using a deployed version of your code? Note that the subject of this topic is about deploying an FPGA application.
    I forgot I posted here, in the mean time I've managed to deploy my application. I think my problem was solved when I included all necessary drivers and components (but I'm not absolutely sure). I included the following:
    NI IVI Compliance Package
    NI FlexRIO
    NI PXI Platform Services Configuration Support
    NI R Series Multifunction RIO
    NI DAQmx Core Runtime
    NI DAQmx MAX Configuration Support
    NI RIO
    Good luck!

  • Getting error 1035 using teststand deployment​.

    Whenever I do a Teststand deployment and I select to password protect my VI's, I get a very freindly and descriptive: Error 1035. I assume (because I am a LV user and have been trained to decode cryptic error messages) that this means that one of my VI's cannot be password protected. Any help is appreaciated.
    Michael Aivaliotis
    VI Shots LLC

    Hi Michael,
    I have been able to reproduce the error on my end and I have something I would like you to try. 
    The proper way to deploy a Project Library (*.lvlib) from TestStand is
    to insert a Deploy Library step before you call the VI with the shared
    variables.  To get the Deploy Library step you right click in your
    sequence and go to Insert Step » LabVIEW Utility » Deploy Library. 
    Right click on this step and go to Configure Deploy Library...  Change
    the Library Path to the Project Library (*.lvlib) that contains your
    shared variables.  Set the Operation to Deploy.  When you are done
    calling the VIs, you need to Undeploy using the
    same step.  Set the Operation to Undeploy.
    Also, make sure you add the .lvlib file to the workspace as well.  In the example you posted, when I completed these steps, I could build the deployment successfully.  I hope this helps!
    Matt S
    National Instruments
    Applications Engineer

  • Problem with variables in formulas when using CrystalReportViewer

    Post Author: Aksu
    CA Forum: Formula
    Hi! I have a problem with variables in Crystal Reports formulas, when using CrystalDecisions.Windows.Forms.CrystalReportViewer class from VS2005-project. ReportViewer always gives error:*************Crystal Report Windows Forms ViewerThis field name is not known.Details: errorKindError in File C:\{dir&#93;}\{file}.rpt:Error in formula <mCustomerAttributes>.'Dim result As String'This field name is not known.Details: errorKind ************* Report without variables works fine with Viewer and in Crystal Reports Designer report with variables works also fine. I have tried with both "formula-syntaxes" - basic and crystal. But Viewer always gives error when trying to define new variable.I think the problem might be with CR -versions, because VS-project has formerly been designed to VS2003 and CR9 or 10. Now I'm using VS2005 and CR11. Though I have changed all references to new CrystalDecisions-asseblies (Ver.11.0.3300.0), when I debug the project and checkout the Viewers ReportSources FormatEngine Shows version CR9_2.... I have no idea where it gets this version...***************DEBUG-view when Viewer is created *******************CrystalReportViewer    |_        ReportSourceClassFactoryName ... , Version=11.0.3300.0 , ...    |_            ReportSource            |_                FormatEngine    {CrystalDecisions.CrystalReports.Engine.FormatEngine}                        |_                        ClientVersionHeader    {CrystalDecisions.Shared.ReportServiceVersionHeader}                            |_                            |    version = 920     (int)                            |_                                Static members                                            |_                                        VER_CR9    = 920    (int)**************************************** Could anyone have any answers or tips for this problem? I'd really appreciate it... ---Aksu

    Has anyone been able to answer this question?
    I am having the same problem:
    I am designing a report in Crystal Reports XI Developer that contains parameters, which are passed to a stored procedure and are also used within formulas ( in Crystal Syntax ie. {?FORMAT_ID} ) in the report itself.
    I can run the report successfully in CRXI Developer.  The formulas use the correct values from the parameters entered during execution and everything looks good.
    I then deploy the report to Business Objects Enterprise XI.  I do all of the things necessary to manage the report including setting up the proper database connection information and default parameter values.
    When I run the report using the Crystal Report Viewer, I get the following error message:
    Error in File Forecasting.rpt:
    Error in formula <Report Format>.
    'if (not isNull({?FORMAT_ID} ) ) then
    This field name is not known.
    Details: errorKind
    This happens when I press the "Preview" button in the Manage Object dialog from Crystal or when I run the report using InfoView.
    I have changed the formulas and it doesn't seem to matter what the specific content of the formula is; other than the existence of a parameter reference in the formula.  If I comment out the parameter and replace it with a hard-coded value, it gets through the formula fine.
    Does Business Objects Enterprise XI support crystal reports with parameter references in the formulas?
    Thanks,
    Tim H.
    Edited by: Tim Haley on Nov 25, 2008 11:11 PM
    Edited by: Tim Haley on Nov 25, 2008 11:12 PM

  • Error code 1127 when using teststand deployment utility

    I'm have installed on my pc Teststand 3.0 and labview 7.0 -this error occurs during build
    Error Code:1127
    Could not process LabVIEW VIs. Fix any broken VIs before rebuilding. LabVIEW error:
    Open VI Reference in TestStand - Dist Chg and Save VIs.vi->TestStand - Dist Build LLB Image.vi->TestStand - Build VI Distribution.vi->TestStand - Build VI Distribution AX Wrapper.vi->TestStand - Build VI Distribution AX Wrapper.vi.ProxyCaller

    >>>>>>>ok, I'm getting a different error code: error code 7 instead of a error code 1127 with the error:
    Error Code:7 Could not process LabVIEW VIs. Fix any broken VIs before rebuilding. LabVIEW
    error: Invoke Node in TestStand - Dist Cmp Settings to Disk Hier.vi->TestStand - Build VI
    Distribution.vi->TestStand - Build VI Distribution AX Wrapper.vi->TestStand - Build VI
    Distribution AX Wrapper.vi.ProxyCaller
    >>>>>>>>And I did a mass compile of the directory mentioned above and I got this error:
    #### Starting Mass Compile: Thu, Jul 15, 2004 9:44:04 PM
    Directory: "C:\Program Files\National Instruments\TestStand
    3.0\Components\NI\Tools\Deployment Utility"
    CompileFolder: error 13 at C:\Program Files\National Instruments\TestStand 3.0\Compon
    ents\NI\Tools\Deployment Utility\DeploymentUtility.exe
    #### Finished Mass Compile: Thu, Jul 15, 2004 9:44:17 PM

  • Any problem with a single MySQL database used on more than one site?

    I have a set of multiple sites hosted separately I'm working on. I'd like to set up a PHP/MySQL database on one site, and be able to pull data from it for completely separate sites. Seems like it shouldn't be a problem. Are there any problems with doing this I need to be aware of?

    I've set up databases on three different hosts, and in all cases I could access the databases from outside the domain of the site itslef.  GoDaddy is one of them, they used to restrict it, but now they give you the option when setting up a new database on your account.

  • Problem with Chroma/Lume Keys while using Drop Shadows

    I have been using the box now for almost two years and I still am getting problems with green/blue/purples artifacts showing up after a chroma/luma key has been applied with a drop shadow. The artifacts do not show up under a preview but only when the sequence has been rendered. As soon as I take the drop shadow off, the artifacts go away. This is happening with both still graphics with or without Alphas and green/blue screen video. Please help, am I just missing something or is there a work around that I could be using.
    Thanks,
    Alex

    c'mon, Bogie - tell us what you really feel - don't hold back... < </div>
    Oh, Patrick, buddy, I am so totally torqued out of shape today. Don't get me started. Too late. FCP's insane render handler is dropping my files, seemingly at random. The nests, Motion and LiveType material are not rendering in the correct order which makes the effects all wonky.
    I add drop shadows in the last stage and FCP just ain't holding it together. I get glitches. And then I keep getting these Media Offline notices because FCP cant' track the render files that are actually in use in the upstream nests.
    I'll certainly admit a likely a user error. I just don't know what it could be. I've somehow told FCP to destroy its children.
    bogiesan

  • Problem with underground cable - engineer visit re...

    I reported a fault on my line last week, and an Openreach engineer turned up on Friday and confirmed that the fault was in an undergound cable on public land, and not within the boundary of my property. There are two nearby BT access covers in the public footpath outside - apparently the line is ok from the house to the nearest box, and the fault is between that box and the next one.
    According to the Openreach engineer, the next step would be for them to come out and trace the exact location of the fault (which wouldn't require access to my property), then the footpath would be dug up so that the cable could be renewed or repaired.
    It appears that BT Retail has a different viewpoint to that of Openreach, as the fault summary on bt.com now says that an engineer visit is required. However, until the cable is repaired I haven't a clue what this is supposed to achieve that the first one didn't.
    Is this a case of Openreach and BT Retail struggling to communicate properly with each other, or is there actually some point to having another engineer visit that I may have missed? Before I arrange to take yet time off work to wait for an engineer, I'd like to make sure that it's really necessary.

    The plot thickens...
    Wife phoned to try to find out more, and during a rather frustrating phone call she was informed that the fault outside was fixed on Sunday morning, and they now want an engineer to come and check that it works up to the house. Plus the usual threat of a £129 charge. So we have an engineer booked to visit on Friday morning.
    I do have a number of problems with the statements made by the individual that my wife spoke to:
    1. An Openreach engineer has already checked that the line is ok from the master socket to the BT "hole in the ground" located 12 metres away, on public land and not within the property boundary. He estimated that the fault in the cable was 15 metres away, between the nearest access point and the next one (which is about 16 metres away).
    2. I'd have thought that we'd have noticed someone digging up the tarmac on a Sunday morning, in view of the front window, but we didn't. Neither did we notice them filling in the hole afterwards. Perhaps Openreach employ silent (and invisible) contractors to dig up the roads at weekends.
    3. More importantly, the line is a dead as ever, and dialling it from a different line or a mobile always gets an engaged tone - this hasn't changed since the fault was reported to BT.
    I'd certainly not be very happy with a £129 charge, particularly as if the problem is within our boundary the engineer that came last week should have found it. Hopefully Friday won't be a total waste of time, for me or for the Openreach engineer, but not holding out much hope at the moment as nothing seems to have changed since the first visit.
    On the plus side, it's been quieter in the evenings as the telespammers haven't been able to get through for the past week or so!

  • Problems with symbol characters in WIKI using plaintext authentication

    Hi!
    I have a Lion Server with Wiki service enabled, and using plaintext to authenticate against third provider LDAP server (Oracle/SUN ldap server).
    The authentication fails if the password has a at least & character inside (I do not test another symbols).
    If the password has just letters and number it does not fails.
    Any Idea how to fix it?
    It is a new "feature" in the Wiki service???
    Thanks in advance
    H.

    Same problem when I use Chinese.
    The only thing we can do now is to wait for an update! Which is hopefully make the Playbook worth something!

  • Problem with too small page size using Java 2D Printing API.

    Hello,
    I have problem with resolution of printer using Java 2D Printing API. Despite my printer has 600 x 600 DPI, inside java.awt.print.Printable.print(Graphics, PageFormat, int) I receive page format with 600 x 840 page size.
    I have tried to set resolution using javax.print.attribute.PrintRequestAttributeSetand javax.print.attribute.standard.PrinterResolution, but with no result.
    Can anybody solve this problem?
    Regards,
    Karl.

    600 x 840 is a Point value; Point is defined as 1/72nd of an inch. Printers do have much higher DPI than this, but I believe that this DPI has to do with richness of the printed image, not an actual ability to color with that level of resolution. You might want to try calling zoom on your Graphics2D object. Otherwise, I don't know what else you can try.

Maybe you are looking for

  • How to set alarm on iPhone 5 to play music from a playlist?

    I'd like to set alarm on my iPhone 5 to play music from a playlist or from a album in Music, i.e. when alarm goes off, it will play more than just one song like songs in a playlist. This setting option was present in my old iPods (iPod Classic and iP

  • Exporting a 16:9 sequence always ends up 4:3?

    Hi - I use FCE HD and shoot anamorphic 16:9 widescreen. I capture in FCE, and edit it in 16:9 as FCE has corrected identified the clips as widescreen. However, if I export if to Quicktime Movie then it always loses the anamorphic and comes out at 4:3

  • BOOTMGR is missing press ctrl+alt+delete to restart.

    Hello there! I'm having trouble since i formatted my t61's primary hard drive, after i did that i thought i could recover the operating system simply by using the recovery DVD's but for my surprise when i turned on the laptop to begin the recovery pr

  • How do I update my Nvidia graphics drivers on Bootcamp using Windows 8.1

    Hey all, I have been running bootcamp with my MacBook Pro with retina display, mid 2013 model for quite some time, but only recently did the windows 8.1 update from windows 8. I have been prompted by some games, namely Fifa 15, to update to the lates

  • Quantity issue in COWBPACK transaction

    Hello All, I have a problem while posting quantity to be packed in "COWBPACK" transaction.  In our system we are giving  LB while packing, where as base unit in material master is kg.  While converting LB to KG as quantity decimal places are only 3,