Problem with FM NAMETAB_GET in Unicode system

Hi everyone,
I'm working in a landscape that has a non-unicode development, non-unicode testing, unicode testing and non-unicode production. The intention is to have a unicode production in the future.
I have an application that has been developed to visualize IDocs so that end users will use this application instead of WE02, WE05, etc (don't know why and this can't be changed). The thing is that this application uses FM NAMETAB_GET to get the fields of the segment, the dictionary length and the offset in order to parse the IDoc.
In non-unicode systems it works fine, but after testing in the unicode system, we found out that it wasn't parsing right, and the problem is that FM NAMETAB_GET is doubling the length of the fields (I guess because Unicode chars need 2 bytes). So the length and offset are wrong and my segment is parsed incorrectly. Does anyone know how to solve this? Is it anyway to tell this FM to work IN CHARACTER MODE? Remember that I can't divide the lenght by 2 because I have some non-unicode systems in the landscape.
Best regards and thank you!
Pablo

Problem solved, I will directly use FM DDIF_NAMETAB_GET which gives me the desired data in DFIES_TAB: Thanks

Similar Messages

  • Problem with cl_abap_char_utilities= horizontal_tab in Unicode system

    Hello Experts,
    My code in 4.7 system was,
    *DATA: gf_tab TYPE x VALUE '9'.
      CONCATENATE '[bc^bd128]' gp_user gf_tab gp_pw '[/]'
      INTO        gf_anmeldung.
      WRITE:  30  gf_anmeldung.*
    The output will be printed to a barcode printer and we get the barcode.  The barcode contains, the user name, tab delimiter and the password.
    Now, Using a scanner (handheld device) we scan the barcode.  The scanner is connected to the SAP server.  So as we give the user name and the password in the SAP easy access screen, the scanner takes the values from the barcode.  This means, the user name from the barcode ->to the user name field, tab delimter -> to come to the next field, password from the barcode ->to the password field.  This logins the SAP in the handheld device.
    Now, in ECC 6 system, the code was changed as below,
    DATA: gf_tab TYPE c VALUE cl_abap_char_utilities=>horizontal_tab.
    After this change, now the scanner is not recognizing and throws the error "fill in all the required fields"
    I am not sure, if it is not retrieving the user name or the tab delimiter is creating the problem.
    Any suggestion would be appreciated.
    Cheers,
    Balaji
    Edited by: Balaji Dhandapani on Feb 3, 2010 6:34 PM

    Hi ,
    I think in the older version u r using the '09' as the end of line , So in the barcode it is consideringthe user id and then thinking that end of line and putting the next string say password in the correct postion.
    Try to use the CR_LF( Carriage return and line feed).
    Try this.
    Regards,
    Bharani.

  • HP Officejet Pro 8600+ "There is a problem with the printer or ink system..."

    I have an HP Officejet Pro 8600+ that is coming up with an error message. This just happened out of the blue yesterday. The printer is just over a year old.
    It says:
    "There is a problem with the printer or ink system. Print head missing not detected incorectly installed or incompatable" 
    I have removed and reinstalled ink cartridges, the head, unplugged, cleaned, etc. etc.
    HP Officejet Pro 8600+
    Product Number CM750A
    Serial Number {Content Removed}
    Not under warranty
    Please advise.
    This question was solved.
    View Solution.

    Sorry that you are experiencing this problem. Here is a link that may assist you with the ink system.
    http://goo.gl/BXDFf
    It seems to be a bad print head, or it needs manually cleaned with lint free cloth and water. If these steps do not resolve the issue, contact HP Support (1800-474-6836).
    **Click the KUDOS star on the left to say 'Thanks'**
    Please mark a reply "ACCEPTED AS SOLUTION" if it solved your problem, so others can find it.

  • Problem with the printer or ink system code 0x610000f6 HP model 6700 premium

    Hello, I have recieved an alert for the second time in a week stating that there is a problem with the printer or ink system. The alert prompts me  to turn off, then on the printer. If problem persists, contact HP. 0x610000f6. What could be the cause for this type of alert to appear?

    '0x610000f6' error message appears if there is a 'Paper Jam' or a 'Carriage Jam' in the printer.
    You can experience following issues:
    The product won't print.
    The print job stops unexpectedly.
    To resolve Error code '0x610000f6' follow methods provided in below mentioned link
    http://h10025.www1.hp.com/ewfrf/wc/document?cc=us&lc=en&docname=c01620497

  • There is a problem with the printer or ink system.

    Will not print. Turn it off then back on; will print one document, but not the last page. Try printing only the last page, but will not print. Will not print one page documents at all. Will not print more than one document without repeating this process.
    First Error message: "There is a problem with the printer or ink system. Turn the printer off, then on. If you continue to get this message, contact HP." Out of warranty.
    Tried this page: http://support.hp.com/us-en/document/c03081973
    Which led me to this page: http://support.hp.com/us-en/document/c03262508
    Now that the ink cartridges are removed as instructed, the carriage will not return to the center of the access area.

    Hey @KennyBee51,
    Thanks again for getting back to me regarding this issue.
    I would have to agree that the HP Officejets Printhead system is defective. I would recommend at this time that you contact our Technical Support queue by phone to explore additional hardware options.
    HP Technical Support can be reached at: 800-474-6836.
    If you live outside the US/Canada Region, please click the link below to get the support number for your region.
    HP Worldwide Contact
    It has been a pleasure working with you. I wish you luck going forward with this!
    X-23
    I work on behalf of HP
    Please click "Accept as Solution" if you feel my post solved your issue, it will help others find the solution.
    Click the "Kudos, Thumbs Up" on the right to say "Thanks" for helping!

  • Problem with the printer or ink system. Turn printer off message.

    A message on the printer reads that there is a problem with the printer or ink cartridges.  I turned off printer several times, I have replaced cartridges.  At the bottom it says to contact HP. What do I do to get my printer working again? I also need to delete other printers that are listed as ones that I can use.  I don't have any idea about these other printers other than the HP printer 6700, All in one.

    Hi , I understand you are seeing an error stating there is an problem with the printer or ink system. If you have completed the solutions presented in the following document I suggest calling us: HP Officejet Printers - 'Problem with Ink System' Error Message Displays on the Computer During Setup. To reach somebody in tech support, what you can do, is use the following link to create yourself a case number, then call and it may help speed up the call process:
    Step 1. Open link: www.hp.com/contacthp/
    Step 2. Enter Product number or select to auto detect
    Step 3. Scroll down to "Still need help? Complete the form to select your contact options"
    Step 4. Scroll down and click on: HP contact options - click on Get phone number
    Case number and phone number appear.

  • Genius needs to help! problems with my video card and system

    Hey guys! I'm going to post my specs first so that you get a good idea of what I'm running on:
    MSI Neo2 LS 865PE.....MAT=Slow
    Pentium4 2.4C.....FSB=233=2.8C hyperthreading enabled ~>1.55V
    Corsair TwinX 1gig PC3700.....memory on "AUTO" in BIOS with timings at 3,4,4,8 ~> 2.7V
    Radeon 9700NP.....stock speeds ~>1.7V
    AlienX case with 2 fan400 watt power supply and 6 case fans
    Zalman Alum/Copper heatsink fan
    1:I've had this motherboard for a few months now. I upgraded my video card from a nVidia Ti4200(128meg) to a Radeon 9800 a month ago, but I couldn't get it working at 8X AGP, no matter what voltages I threw at it. I returned it for a Radeon 9700NP hoping that it would work, but it still won't.
    I'm using BIOS 1.9 and since there is no option to select your AGP speed, I could only try using ATI's drivers. Once booted into Windows, there is a slider you can move to select you AGP speed. On my machine It says that It has performed some tests and has concluded that AGP 4x is the best for my system....but my system supports AGP 8X!
    I've moved the slider over to 8x (which requires a reboot) at least 5 times with each card but the slider refuses to move past 4xAGP after the reboot.
    2: My second problem: I had an old stick of KingMax PC3200 and decided to buy 3 more sticks. Unfortunatly, the 3 I bought did not match the one I had, so I only put 2 of the new sticks I bought into my system. Immediatly, My system would crash, lock up, files were corrupt, and I got PLENTY of blue screens of death with a long message containing: 0x0000007  with all these other numbers and "0"s. I did a search online and found out I had a hardware incompatibility problem. I never got this with my old stick of ram.
    I returned the 3 sticks of Ram and replaced them with the Corsair. Put my new Radeon 9700 in, formatted my hard drive....and within 24 hours, my system locked up 3 times, rebooted itself 5 times, and gave me the same BSOD as mentioned above with the same long message.  
    I didn't change anything except for the memory and the video card. I've been wanting to overclock, (thats why i bought the faster memory   ) but I'm not sure what to do at this point.
         I have my FSB at 233 but I'm scared to go any higher because of previous system instability at stock speeds. My RAM was running on 400 and MAT=Turbo with the most relaxed timings at 3,4,4,8.
    I've given myself hours of sleepless nights formatting when my system wouldnt boot into windows; overclocking....etc. I NEED HELP. PLEASE. PLEASE. Anything could work at this point.  
         I'm trying to get more info on how to run my system at a 5:4 ratio, also.  
    If anyone has problems like me or knows what could be the problem with my system, please reply to this post, it would help me a lot. I've been trying to fix these problems for a few months now so anything is greatly appreciated.  

    Thanks a lot to you guys that responded. I brought my computer home this past holiday and I want to let you know where I stand as of now. I guess this thread is like my blog for my computer. I want to clear some things before my first post makes everyone confused.
    1- I have only 2 sticks of memory in my system: the Corsair PC3700 TwinX 512x2
    I returned the 3 KingMax I bought, and still keep my old stick just in case.
    2- I am using the 400 watt power supply that came with the case. I read some reviews of the case and I know the reviewer did not have problems with the power supply. In my BIOS, there are some voltages it is weak on. Lets say: it it should be 5.00+, my power supply will be feeding it 4.96v or something like that, but I dont know, or think, that is a major problem...
    3- My computer will refuse to boot if memory speeds are set at anything below 400. SO....if I want to use a 5:4 ratio and have to set my memory speeds to "333" in BIOS, my system refuses to boot.
    4- This morning, I did manage to overclock my FSB to 250. Specs are as follow:
    Memory Timing @3,4,4,8,4.....speed set at "AUTO".....MAT at "SLOW"
    MY 2.4C's FSB was raised to 250 = 3.0gig  
    AGP/PCI frequency: 67.xx/3x.xx (cant go any lower)
    CPU voltage: 1.5500
    Memory voltage: 2.75
    Video Card voltage: 1.7
         Everything was fine for the whole day until I heard something click in my computer around midnight, and then seconds later, my computer froze and made a continuous beeeeeeeeeeeeeeeeeep. (you can imagine)
         This "click" and system crash has been plaguing me for months now. I dont know whay it happens. I was just using AIM when I heard the click and my heart stopped.
    My memory speeds have been set to "AUTO" even at the FSB of 250. But I don't know if this still means my system is at a 1:1 ratio. I know the BIOS then adjusts the memory to work at 500 if my FSB is 250...so I assume it is?    I love 3gig, but somehow I feel that 2.8 is faster, since the FSB=233 running parallel to my memory, also at 233
    A FSB of 250 is good enough for me, that's what I've been waiting 6 months for. If anyone knows how to set other ratios to achieve a FSB of 250+, please let me know, but as I said, my memory won't boot if its set at "333"

  • Problem with TMS setup in HA systems

    Dear colleagues,
    Our team have installed a new production environmnent to ECC in HA. We have a ASCS in cluster and two dialog instance in each server(local instance).
    A virtual host GPPR3CIB and two instances in local, node GPPR301 and node GPPR302. This is an ECC 6.0 on Windows 2003 Server and SQL server 2005.
    The architecture is as follows:
    - GPPR301 node:
       - Virtual ASCS ASCS_0 (message server)
       - ABAP Primary Instance PPR301_1 (disp+work)
       - ERS (Enqueue replication server) instace ERS_10
    - GPPR302 node:
       -ABAP Additional Instance PPR302_2 (disp+work)
       -Virtual Database Instance GPPR3DB
       -ERS (Enqueue replication server) Instance ERS_10
    Once the installation is complete you need to apply SAP Note No. 943334 - "TMS setup in high availability systems" to set up high availability STMS. The problem is to distribute the configuration after running
    the report " 'TMS_MGR_LOADBALANCING" described in SAP note.
    The message indicates problems trying to run the command tp.exe. It has followed the note No. 1010990 and we have checked the folder permissions of the kernel but the problem persists.
    Any information or help regarding this type of setup would be welcome.
    Thanks.

    Hi,
    We have solved the problem with STMS. After several tests, the problem was in the parameter SAPLOCALHOSTFULL. This parameter must be assigned the hostname of the local system for each profile instance. If you've assigned the virtual host in the cluster generates the error in the distribution of the STMS.
    Regards.

  • Concatenate with 'tab' delimiter in Unicode system

    Hi All,
    In current system we have a program that creates a tab-delimited file with following code where wa1 and wa2 are character-type fields.
    data: delim type x value '09'.   (a tab in hex)
    concatenate wa1 delim wa2 into wm_lstfil.
    Unicode system won't allow char and hex fields to intermix.  Suggestions on how to replace this code so that we continue to create a tab-delimited output line?
    Thanks,
    Kirsten

    Hi
    You can use the following...
    CLASS cl_abap_char_utilities DEFINITION LOAD.
    DATA: text TYPE string.
    <b>Concatenate your data into variable text .... and then,</b>
    REPLACE cl_abap_char_utilites=>horizontal_tab WITH space INTO text.
    Regards,
    Raj

  • Problem with field-symbols in UNICODE conversion

    Hi all.
    I'm in a UNICODE conversion project and I have a problem with a program that uses field-symbols.
    DATA: BEGIN OF wa_data_aux,
            mandt LIKE zindices-mandt,
            kschl LIKE zindices-kschl,
            datab LIKE zindices-datab,
            valor LIKE zindices-valor,
            descripcion LIKE zindices-descripcion,
            ernam LIKE zindices-ernam,
            erdat LIKE zindices-erdat,
            waers LIKE zindices-waers,
          END OF wa_data_aux.
    FIELD-SYMBOLS:
                   <fs2>  TYPE ANY,
                   <fs3>  LIKE wa_data_aux.
              <fs2> = <fs3>.
    This assignment results in a DUMP.
    Can anybody help me to solve this problem?
    Thanks!!

    TYPES: BEGIN OF wa_data_aux,
              mandt TYPE mandt,
              kschl TYPE kschl,
              erdat TYPE d,
              waers TYPE waers,
          END OF wa_data_aux.
    DATA: w_aux TYPE wa_data_aux.
    FIELD-SYMBOLS:
    <fs2> TYPE ANY,
    <fs3> TYPE wa_data_aux.
    w_aux-mandt = '300'.
    ASSIGN w_aux TO <fs3>.
    ASSIGN <fs3> TO <fs2>.
    WRITE : / <fs2>.
    GBY.

  • Bizarre networking problem with multiple 8.1 GA systems -- RT and Pro

    Hi everyone,
    I'm having a particularly bizarre problem with the networking on two Windows 8.1 machines, one running Pro and one running RT. Both demonstrate the same behavior.
    In both cases, networking (wireless most of the time, although I'm not sure it matters) works fine for some period of time. Eventually it just stops working. Resetting the adapter, or flipping in and out of Airplane mode will bring it back again. The issues
    happen on at least 3 wireless access points.  In most cases, the networking actually appears to be up -- the limited access warning icon isn't up, although occasionally it does realize the networking isn't working.
    Here's the bizarre part -- on both systems, local IP connectivity is fine. I can communicate perfectly well between devices on the same internal network, wired or wifi. During the time the networking isn't working on one or the other 8.1 system, other systems
    on the network running Windows 8 (and other systems) work fine. There's no correlation between one 8.1 system stopping working and the other.
    On *both* systems, when the networking appears to be failing, a traceroute actually gets 4-5 (or more) hops before going out to lunch. Other systems on the same internal network will cruise along to the same point on the route that is failing on the 8.1
    machines and keep right on happily continuing the trace.
    So that's the bizarre thing -- something on two 8.1 machines is doing *something* to the packets that is causing them to not route properly to a target system 10-15 hops away, the same routers handling the same kind of traffic from other systems behind my
    firewall work fine, and whatever is happening to the packets that is causing issues resolves itself for some period of time if I reset the adapter.  (The two systems are a MacBook Air and a Surface RT, so there's no drivers in common between them, either.)
    I'm completely at a loss. Anyone see anything like this before, or have any thoughts on what to check?
    (And, please, if you're one of those Microsoft support forum people who skim questions for keywords and cut-n-paste back a generic reply without any actual understanding of the problem -- like so many replies on here -- please do not waste my time. I am
    trying to find someone who knows Windows 8.1 networking, not someone who knows just enough English to use ctrl-c/ctrl-v)

    Hi George,
    There is a known issue about Cisco device. It caused some windows 8 clients disconnected from wifi. I understand your windows 8 clients works fine, when the issue occurred on windows 8.1 clients. However, I think the KB article is worth a shot
    http://support.microsoft.com/kb/2749073
    Best regards,
    Alex Du
    Please remember to click “Mark as Answer” on the post that helps you, and to click “Unmark as Answer” if a marked post does not actually answer your question. This can be beneficial to other community members reading the thread

  • Please can anyone help with the continuing password rejection problem with email.Ipad and other systems work fine but despite reloading my password on imac it bounces back.Apple store has been visited and I have tried everything they suggest.

    Please can anyone help with the continuing password rejection problem with email on my imac.My Ipad and other systems work fine but despite reloading my password on imac it bounces back.Apple store has been visited and I have tried everything they suggest.

    I use free Yahoo mail webMail access because folders I created in webmail access doesn't get set up in Apple Mail. While I was searching for post about password and keychain issues, I stumbled on several threads that complain about Mail folder issues, so I'm holding off on Apple Mail.
    On the password and keychain issue that your post is all about.  I've been using login keychain to save and automatical fill my login screens for a year or so successfully, with Safari and Chrome. Automatic form fill also works for Facebook login. Unfortunately, about 4 to 6 months ago, automatic password form fill stopped working with Yahoo webmail, while still worked for GMail (Safari and Chrome). I tried deleting the password entry for my two Yahoo email accounts to start fresh, but neither Safari not Chrome will even ask me if I want to save the password. I was so frustrated that I eventually installed the keypassX 0.43 (password manager) that is quite primitive sompare to OS X's keychain (when it works). Probably no surprise to you yet.
    The surprise, to me at least, is that, for whatever reason, password auto form-fill from keychain started working again for Yahoo webmail login on Safari about 5-7 days ago. Still doesn't work on Chrome!
    Two tips I can share, at least with webmail access:
    1. Password is save only for one of my yahoo mail accounts. When I login in with my other yahoo account, I get no prompt to save the password, and form fill doesn't work when I try to log in a second time with my other Yahoo mail account.
    2. On inspection of my login keychain, I see a webform password item saved for my Yahoo account that works with keychain. The name of the password is: login.yahoo.com(MyAccountName1#). When I open the password item and look in the Access Control tab, I see Safari and Chome are listed as allowed to access this password item..
         I also an "Internet password" item with a name of just login.yahoo.com. When I open the the password item, it looks just like the password item created for MyAccountName#1, but the MyAccountName#2 is listed in the Account field. Inside the Access Control tab, no apps are listed in access permission. I added Safari and Chrome to the lists of allowed app, saved the password item.
    Now when I bring up the Yahoo login page(by bookmark) on Safari, form fill fills in MyAccountname#1 for name and the proper password and I can login in. When I change the name to MyAccountName#2, the correct password is retrieved and I can log in! Alas, it still doesn't work on Chrome.
    BTW, I changed the password item type from "Internet password" to "Web Form password" and saw no difference! I also edited the name to be "login.yahoo.com (MyAccountName#2)" to look like the web form password item that works, but it has no effect either.
    From my experimentation, here's my observation:
    1. A Web Form password item is created for the first account name(MyAccountName#1) for login.yahoo.com and typed as Web Form password. When I log in using MyAccountName#2, an Internet Password is created, but no applications are listed as allowed to access the password item, even when the password item was created after just logged in and logged out to yahoo with the account name and password for MyAccountName#2.
    2. Manually adding Safari as an app that is allowed to use the password item works. Doesn't work with Chrome!
    The version of Safari I'm using is Version 5.1.7 (6534.57.2). My installed version of Chrome is Version 21.0.1180.79 beta.

  • Problem with T7700 7.1 Speaker System

    I'm currently having a problem with the speaker system named above. For no reason at all, whether I'm playing a game, watching a mpg or listening to mp3's, the volume on the speakers raises and lowers every few seconds for no apparent reason. This has been happening for a few months now. (I bought the speakers December 2003) I've ruled out the sound card (Audigy 2 ZS) because I've tried these speakers on two different systems. Any ideas what it could be or if you need any more info, please let me know. Thanks.

    I can't read good, I didn't see your hardware. My mistake.
    I reinstalled my drivers, and that seems to have helped. I think it may have had something to do with Windows XP SP2 or my onboard sound, I don't know for sure though.

  • Problems with my 5.1 surround system

    Hi everyone, for sometime now i've had some problems with my 5.1 speakers, the thing is when i watch youtube, vimeo or that kind of webs i only hear 2 of the five speakers and let me tell you, it sounds like crap...so i was wondering if any of you could help me fix this problem.
    greets!

    A Year Later...   has this been fixed?
    I have a SB Recon3D PCIe card (and older, lesser version of yours), and I have exactly the same problem. I'm on Windows 7 x64 and CS6. It is interesting that in Audition CS6, When I select the MME Device Class, that my channel mapping shows 6 channels, and when I play files back in Audition, I get full 5.1 surround. But, when I try the same thing in Pr, even taking the 5.1 file created and exported as WAV from Au into Pr, where I can see all 6 channels mapped correctly and the meter shows the correct volumes in each channel when played back in Pr, I hear only Stereo. Channel mapping in Pr shows the same thing yours does.
    The bad part (or good, from my perspective) is, I was planning on buying the SB Z to hopefully FIX this problem thinking perhaps it was just a Recon3D problem. So I guess that's out. Can you get Audition CC to work correctly in Surround? Give it a try.
    From my perspective, it appears to be a Premiere Pro issue, apparently from CS5 (when it went native 64 bit) that still haunts us all. HAS ANYBODY GOTTEN 5.1 TO WORK IN PREMIERE PRO?
    Cheers,
    Shane

  • Hi!!I have some problems with the synchronization of my system, and I don´t know how I can solve this!

    My system consists of differents vi´s.Some of them are used to read analogic inputs and digital inputs, using the serial port.
    The values that I read, go through differents vi to be proccesed, and at the end, these values are written in a file, all the values in the same file.
    My problems of synchronization are:
    1. I have one vi per input, and all of them use the same serial port. How can I synchronize them to avoid serial port conflicts? (using queues??) And how can I do, to get differents number of samples/sg with every vi? I have to introduce them in differents loops?
    2. The other problem is that, for example, I want to read 8 samples/ s but I only want
    to write two samples every second. How can I do to avoid stoping the data flow?
    Maybe, my problem is that I want to see the system like
    one block, and I am ignoring that, although all the system works like a block, every part works using a different "speed". I don´t know how tools can I use to combine two ideas, working like an only system( data dependence, some vis need the data of others vi to be able to work) and working getting differents numbers of samples/s.
    I have seen that there are synchronization vis. I am going to glance at them, maybe I find something interesting but I amsure that your help will be very useful?
    Thanks in advanced!!
    Graci

    I think you are pretty much on the right track with Queues. I have implemented a very similar system myself using queues. I have even different systems connected to the serial interface, but I can synchronise them all easily using the following method:
    1) Make a VI for opening the serial port and reading the data. The data (parsed to extract the numbers required) are then stored in an array (Shift register). If the pre-determined time delay is reached (say 5 seconds) the values are averaged and written to a Queue with a defined data type. Save the VI as a VI template.
    2) Make a VI which starts an instance of this template VI for every channel you require. You can use VI Server to set values on the new front panel before you set it's property to "running". Setting a timer value for all can help ensure that the X-Axis of your timing values (if you require) are synchronised. The clue here is to define and initiate a QUEUE per channel. (RS-232_1, RS-232_2 and so on). The QUEUE name needs to be passed to the VI Template before running so that each VI running in the background has an individual link to the main program.
    The second part of this VI simply uses an array of QUEUES, polling them one after another with a timeout of, say 5 ms. If data is found, append accordingly to an XY-Graph.
    I also add in some "Auto termination" in the VI template (MAx number of values allowed in the QUEUE for example) to allow for the background processes to find out if the front-VI is still running or not. There are many different ways to do this, shoose the best for your application.
    With this approach, it's not even important what instrument is connected as long as data is written in a specified format into a known QUEUE. I have also developed systems where I can transparently (almost) drop in VI Templates for instruments with similar functionality (output data) from different suppliers.
    I would post an example, but the time it would take me to clean it up is too large. Sorry. If you have any further questions, don't hesitate to ask further questions.
    Shane.
    Using LV 6.1 and 8.2.1 on W2k (SP4) and WXP (SP2)

Maybe you are looking for