Hi Experts,
     There are a Proxy to JDBC Synchronous interface in Production environment. Here getting  the error " XIAdapterFramework- com.sap.engine.interfaces.messaging.api.exception.MessageExpiredException: Message
4e53d84e-9a45-363a-e100-0000960096aa(INBOUND) expired". We can able to see the inbound payload from R/3 system but can't able to get the response payload from Sql system. At this time in R/3 system's T.code smq2 messages stucking in queues with status" sys fail" with description as " An exception occurred that was not caught. Particularly for this SQL server's interfaces are not working remaining all working smoothly. Asynchronous interfaces are working at the same time.
BASIS team restarted the java stack of PI system, immediately all stucked messages in queues were cleared and issues resolved automatically, but again and again repeating only after 6pm since last 3 days, after restarting the PI java stack automatically resolving the problem. It is not at all the right solution bcz it is PRODUCTION System. Kindly suggest me.
Thanks & Regards,
Srihari.

Hi Srihari,
See thread below:
[MessageExpiredException in the Sync XI--JDBC scenario|MessageExpiredException in the Sync XI--JDBC scenario;
and SAP Notes
[1356789 - Configuring timeout for dummy SQL query in advanced mode|https://websmp230.sap-ag.de/sap(bD1lbiZjPTAwMQ==)/bc/bsp/spn/sapnotes/index2.htm?numm=1356789]
[1078420 - XI/PI JDBC Adapter: Setting JDBC driver properties for DB|https://websmp230.sap-ag.de/sap(bD1lbiZjPTAwMQ==)/bc/bsp/spn/sapnotes/index2.htm?numm=1078420]
[1586058 - XI/PI Adapter for SQL Server:Overcoming DB Connection Issues|https://websmp230.sap-ag.de/sap(bD1lbiZjPTAwMQ==)/bc/bsp/spn/sapnotes/index2.htm?numm=1586058]
[1579879 - Adapter Framework - Message expired exception|https://websmp230.sap-ag.de/sap(bD1lbiZjPTAwMQ==)/bc/bsp/sno/ui_entry/entry.htm?param=69765F6D6F64653D3030312669765F7361706E6F7465735F6E756D6265723D3135373938373926]
Regards.
Pedro Baroni

Similar Messages

  • Weird Problems with K9A2 System

    Can Someone Help Me?
    I recently built a new system and have had nothing but problems.  See system config in signature (Left off OCZ PRO Xtreme 1000W Power Supply With 4 12 Vrails at a max of 26 Amps each or 82 Amp all together and a 5 Volt rail at 30 Amps Max.) After putting it all (except the seagate 250 IDE drive), system would not even enter post. After strippin memory down to just 2 GB system finally entered post (although my memory were the same models from G.Skill one set was older and one set was new they had different voltages old required 1.9-2.0 while the newer worked at the default 1.8 voltage all timing and specs besides voltage were the same). I entered the bios setup and set my Memory voltage to 1.95 (What I had been runnin the older memory in my old system). Inserted all the memory back in and system booted right up to allow me to install my OS (Vista Home Premium 64-bit).
    After the OS installed the system started having all kinds of wierd clitches/problems at one point it locked up and neither reset button nor the power button would work. After unplugging the power I noticed that the M connector for the front case switches was a little loose. I decided to just plug wires directly into board instead of using th M connector. Now my buttons worked again. I then proceded back into the bios and checked my voltages in the hardware monitor of the bios.  All voltages looked to be fine with only an ocassional voltage fluctuation in the 5V line from 4.97 to 4.92 Volts and the 12V line was a little high 12.4 Volts. However, after booting back into vista and installing Everest Ultimate Edition it detected the that the 5 Volt line was only at 4.67 Volts. But was not fluctuating at all.
    After installing the drivers for my system and proceding to install my anti-virus software the system started freaking out the mouse started lagging and sometimes not responding at all and the keyboard worked intermittently.  I decided to remove the M connectors from these as well and that solved that problem.  Upon rebooting the system and trying to install the Anti-Virus software again the system started telling me that I had just plugged in something to the audio connector.  I had not so I just ignored it and continued to install my anti-virus.  (the audio connector alert popped up 4X while I was finishing the installation of the software.  I decided to test the audo so I but a DVD in and and watched the whole movie sound worked fine and no more pop ups about the audio connector until I started to install more software.  During the next install of software the screen went black and the DVD and Hard Drive LED stopped flashing. It stayed this way for about 10 Min. I decided to hit the reset button and the system would not enter post again.
    Once again I started to pull the Memeory It finnally worked after removing the new memory that I had just bought but none of my Maxtor hard drives were recognized and I started smelling smoke. ( Strange only the Maxtor drives went out, all had the interface boards and one chip on each drive fried.  After disconnecting these drives and replacing the maxtor 120 GB IDE drive that had fried with a Seagate 250 GB IDE drive and reinstalling everyting onto it since the maxtor was my boot drive the system started up and was running fine except for the occasioal audio connector popup I finished Installing the rest of my software and everything was running good.  So I assumed the problems were due to faulty ram. I contacted NewEgg and arranges for an RMA  on the memory went shipped the memory back to NewEgg came back and started to move file some file to my NAS200 After about 4 hours the system locked up again (It had been almost 36 hours since I had had anyother problems with the system and it had not been turned off the whole time. All temps were good CPU was at 29C and GPU was at 46C system temp was 31C according to my Everest Ultimate so I didn't think it was a heat related issue) 
    Upon restarting my computer I got a message that a recent overclocking attempt had failed (I did not try to overclock!!) After going back into Bios and resetting all my settings the computer would not post agian. I tried to clear the CMOS with the jumper just to make sure that there wasn't any coruption inthe CMOS. Still no Luck. Pulled out one stick of the older ram and it booted but very slow. I went to a local parts dealer and bought some extremely over prived memory just so I could get my system back to 2 GB because I had video edditing software that didn't work very good on 1 GB. After installing no post again. So I started testing each stick of memory that I had in DIMM 1 they all worked but anytime I insert one into DIMM 2 it would not boot.  Finnally I but 2 sticks into DIMM 3&4 and It started up and ran good. I decided to set my bios Unganged option to enabled and put memory back into DIMM 1 No luck would not post. I removed the memory from DIMM 1 and computer has worked ever fine except for an error coming out from sleep mode. (Never had a computer that didn't have a problem with that) I even updated the BIOS to 1.5 which was suppose to fix the wakeup problem. 
    So here is what I have I can use Dimm 1 by itself or I can use DIMM 3&4 but not both together.  I'm about to buy a Power Supply (single 12V rail at 40 Amps and a 5V rail at 50 Amps) because I think that the 12 V reading as 12.4 and the 5 Volts reading as 4.67 in Everest Ultimate and 4.97 volts in Bios might have something to do with some of my problems.  I did not check the Memory that I RMA'd by them selves on DIMM 3&4.  I think that they may have been good now.
    Can the 5V line registering the way it is 4.97 Bios/4.67 in Windows cause DIMM 2 to not function and create the lockups or can the socket or board be bad and that be what is causing this problem?  And Should I RMA the motherboard back or just purchase a different motherboard?
    System is pretty Stable as it is now with the voltages as they are.  I really wantt to be able to put my new memory that I get back from NewEgg in and have my 4 GB of memory. 

    OK I have removed the mother board and and checked for grounding issue or any damage from the fried hard drives board looks good did not find any grounding issues in the case.  One thing I did not check was that I was using a Startech SATA to IDE converter to connect the the IDE drives that I didn't have the connectors on the board or.
    I did some research before buying them and made sure to get one with a plastic box around the pcb  due to so many people compaining that their's would short to the hard drive case.  Since the loss of the HDD I didn't need the adapter so I quit Using it.
    when I did my research on the adapter I found that many people had said that their HDD got hoter when using the adapter I guess my HDD just couldn't handle it.  The Drive that I had connected with it was about 6 years old and I had been having intermittent problems with the connector not making a good connection when it was in my old system. (Anytime I would shut the power off for a long period of time and the HDD had a chance to cool down I would have to unplug and reconnect the ide cable from that drive.)
    I didn't think that the problem would continue as I was moving it to an new case, motherboard, and cable.
    And it just so happened that the drives that fried were all connected the the sata controller in the SB600 chip.  My two SATA drives that survied the fire were on the Promise T3 controller.  So I guess it is possible that the adapter/HDD configuration I had with the SATA to IDE caused some sort of feedback into the Motherboard's SATA controller and back into the oter HDD on that Controller.  I have checked all SATA ports since this happened and they all still work so I'm assuming that it did not damage the chip. 
    As far as the memory  situattion I don't see how the HDD frying could have damaged the Memory unless there is some special connectin between DIMM2 and the SATA controller that doesn't exist with the other DIMM slots. and if it had somehow effected the memory controller to cause this problem I would assume it would have done alot more damage to the cpu than just the memory controller part. So I think I'll try to RMA a new motherboard, if ZippZoomFly will let me this long after getting the board I've had it for about 3.5 weeks waiting on the other parts for the new system) and see what happens.
    As for the memory, itself they are not mixed brands or models.  I bought one set about a year ago when I purchased my X2 6000 processor and they have worked great as long as I kept the voltage above  1.9 V.  The new memory has the same model # as the old but the label on them states the same timings and only a different voltage range.  So as long as they voltage was set to within the range of both sets they should work exactly the same.  I did notice that the board would only detect 3.25 GB instead of 4 GB, and I was prepared for this. Every Motherboard I have ever owned, no matter who the Manufacturer was, has had this problem.  However Vista reported the memory correctly.
    I guess if the new motherboard exhibits the same memory problem with not letting me use all  slots then i'll buy a 2X2GB set

  • Problems with Sinn7 Audio USB Interface on Mountain Lion

    Hi Guys.
    I have problems with my USB Audio Interface Sinn7 Status 24/96 on Mountain Lion system.
    When i istalled drivers, system doesn't detect the card. After the system reboot, when i pluck the card in to usb, system makes a kernel panic.
    My hardware: MacBook Pro 15'' Late 2011 / OS X Mountain Lion / Audio Interface: Sinn7 Status 24/96.

    Hey DSevenPL,
    Have you sorted this issue yet? I'm having the same problem on my mid 2012 Macbook Pro.
    I had been running the sound card earlier on the same machine that you have (late 2011) w/out a problem but then got the new machine and it wouldn't read the sound card. Same issues as you.
    Months of searching has turned up with nothing (and Sinn is unresponsive) so any insight would be greatly appreciated!
    K x

  • Workstation specs -- Any problems with this system quote?

    Here are the specs I have been quoted.  I'm not terribly knowledgeable about hardware, does anyone see any problems with this system?  I have recently started shooting and editing weddings, engagements and corporate videos.  I think it may be bit more than I need, but I would much prefer that to less than I need.  Any input from the more tech savvy users would be much appreciated.
    Darren Breckles
    65539
    ASUS Sabertooth X79 ATX LGA2011 DDR3 3PCI-E16 2PCI-E SATA3 USB3.0 SLI CrossFireX Audio Motherboard [Sabertooth X79]
    72374
    Mushkin Enhanced Blackline Frostbyte 32GB 4X8GB PC3-12800 DDR3-1600 CL10 Quad Channel Memory Kit [994055]
    64540
    Noctua NH-D14 SE2011 LGA2011 Heatpipe Cooler w/ NF-P14 140mm & NF-P12 120mm PWM Fans [NH-D14 SE2011] [Reg. $89.99]
    67678
    Intel 520 Series 240GB 2.5in SSD MLC 25nm SATA3 Solid State Disk Flash Drive OEM [SSDSC2CW240A310] [Reg. $279.99]
    4729477
    8 port internal via 2X SFF-8087, LSI2208 1GB cache, 6Gb/s, RAID 0/1/10/5/50/6/60 [RS25DB080]
    1
    84358
    MSI GeForce GTX 770 OC Twin Frozr IV 1098/1150MHZ 2GB 7GHZ GDDR5 2xDVI HDMI DP PCI-E 3.0 Video Card [N770 TF 2GD5/OC] [Reg. $429.99]
    62678
    ASUS BW-12B1ST Blu-Ray Writer 12X BD-R 16X DVD+R SATA Black Retail [BW-12B1ST/BLK/G/AS][Reg. $89.98]
    Environmental Fee $0.75 Per Item
    45275
    Microsoft Windows 7 Professional Edition 64Bit DVD SP1 OEM [FQC-04649] [Reg. $153.98]
    75044
    Fractal Design Define R4 ATX Tower Case Black Pearl 2X5.25 8X3.5INT No PSU Front 2XUSB3.0 Audio [FD-CA-DEF-R4-BL] [Reg. $119.99]
    77641
    Corsair AX860 860W ATX 12V V2.31 80 Plus Platinum Modular Power Supply Active PFC 120mm Fa *IR-$10* [CP-9020044-NA] [Reg. $189.89]
    49665
    nMedia ZE-C118 3.5in Multi Function Panel Flash Card Reader W/USB2.0 eSATA SDHC2.0 Win 7 Black [ZE-C118 ] [Reg. $19.99]
    58276
    StarTech.com 3.5in Hard Drive to 5.25in Front Bay Bracket Adapter [BRACKETFDBK]
    78186
    Noctua NF-A14 FLX 140mm Ultra Quiet Cooling Fan 900-1200RPM 115.5M3/H 19.2DBA 3-PIN [NF-A14 FLX] [Reg. $22.99]
    4
    22823
    Premium PC Assembly and Testing With 1 Year Limited NCIX Warranty (PRE-CONFIG WIN. OS If Purchased)
    Environmental Fee $3.00 Per Item
    Note: Includes extra attention to cabling, lighting installation and extra burn-in period. Recommended for windowed cases. Assembly requires an additional 4-5* business days to ship once all parts are in stock. *typical lead time (currently 2-5 business days)
    1
    $3.00
         73920-1
    NCIX 3 Year On-Site Care Coverage for PC $3000.00 - $3999.99 (22823)
    89510
    Intel Core i7 4930K 6 Core 3.4GHZ (3.9GHZ Turbo) 12MB Hyperthreading LGA2011 Processor No HSF [BX80633i74930K] [Reg. $649.99]
    81958
    Western Digital RE 2TB SATA3 7200RPM 64MB Cache 3.5in Internal Hard Drive [WD2000FYYZ] [Reg. $213.57]
    Environmental Fee $0.75 Per Item
    4

    Very nice build list Darren!
    I would have selected the Samsung 840 Pro 256GB SSD over the Intel 520, and Areca's ARC-1882i over the Intel SAS controller you list, but those are preferences not essential changes.
    Regards,
    Jim

  • Remote Resources: "A problem with the system proxy caused the connection to fail: End of file"

    Hi, I am trying to use "Remote Resources" on the current version of the Microsoft Remote Desktop for Android app, I can input the webfeed and it even shows the apps that I have configured on the server for "Remote App", sadly whenever
    I try to load any of the RemoteApps, I receive an error stating " A problem with the system proxy caused the connection to fail. End of File".
    I don't know what I can do to fix this, I've tried many things to no avail, also, normal Remote Desktop connections from the Microsoft Android app work flawlessly to the server.
    The relevant log is the following:
    [2014-Jan-09 04:40:54] RDP (0): ----- BEGIN ACTIVE CONNECTION -----
    [2014-Jan-09 04:40:54] RDP (0): Final rdp configuration used: memory bookmark [
    label 
    hostname DIAZSERVER
    port 3389
    loadbalanceinfo 
    ui.swapmousebutton false
    remote.program ||ZWaveUtil
    remote.workingdirectory 
    remote.name ZWave Adapter Utility
    remote.args 
    rail true
    soundmode 0
    connect_to_console false
    redirectsdcard true
    performance_flags 134
    arc.sessionid 0
    anonymous_username 
    authentication_level 2
    use_redirection_server_name false
    username administrator
    gateway [
      host = DIAZSERVER
      port = 443
      bypass = false
    connect info[
      hostnames = [localhost]
      gatewayHost = DIAZSERVER
      gatewayPort = 443
      routingToken = Cookie: mstshash=administrator
      redirectionGUID = 
      proxyHost = 200.5.68.10
      proxyPort = 8080
      sessionId = -1
    [2014-Jan-09 04:40:54] RDP (0): Using HttpConnect proxy at 200.5.68.10:8080
    [2014-Jan-09 04:40:54] RDP (0): Using Basic Authentication with username ''
    [2014-Jan-09 04:40:54] RDP (0): Protocol state changed to: ProtocolConnectingNetwork(1)
    AsioEndpointContext (0): startup(): starting up down context
    [2014-Jan-09 04:40:54] RDP (0): Resolved '200.5.68.10' to '200.5.68.10' using NameResolveMethod_DNS(1)
    [2014-Jan-09 04:40:54] RDP (0): Resolved '200.5.68.10' to '200.5.68.10' using NameResolveMethod_DNS(1)
    ASIOSocketAdapter (9): readSomething error. message: End of file. instance: 0x5d39d5c0
    RpcOverHttp (9): Stream error in endpoint 0x5abbc170 : A problem with the system proxy caused the connection to fail: End of file
    [2014-Jan-09 04:40:55] RDP (0): Error message: A problem with the system proxy caused the connection to fail: End of file
    [2014-Jan-09 04:40:55] RDP (0): Error message: A problem with the system proxy caused the connection to fail: End of file
    [2014-Jan-09 04:40:55] RDP (0): Protocol state changed to: ProtocolDisconnected(8)
    ASIOSocketAdapter (9): handleRead(): exception: Exception in file '/var/lib/jenkins/jobs/rc-android-app/workspace/rdp-layer/library/jni/librdp/private/httpendpoint.cpp' at line 489
        User Message : Failed to read from channel: -1. instance: 0x5d39d5c0
    [2014-Jan-09 04:40:55] RDP (0): Disconnect initiated by client
    RpcOverHttp (9): Exception in endpoint 0x5abbc170 : Exception in file '/var/lib/jenkins/jobs/rc-android-app/workspace/rdp-layer/library/jni/librdp/private/httpendpoint.cpp' at line 489
        User Message : A problem with the system proxy caused the connection to fail: Failed to read from channel: -1
    [2014-Jan-09 04:40:55] RDP (0): Exception caught: Exception in file '/var/lib/jenkins/jobs/rc-android-app/workspace/rdp-layer/library/jni/librdp/private/httpendpoint.cpp' at line 489
        User Message : A problem with the system proxy caused the connection to fail: Failed to read from channel: -1
    [2014-Jan-09 04:40:55] RDP (0): Exception caught: Exception in file '/var/lib/jenkins/jobs/rc-android-app/workspace/rdp-layer/library/jni/librdp/private/httpendpoint.cpp' at line 489
        User Message : A problem with the system proxy caused the connection to fail: Failed to read from channel: -1
    AsioEndpointContext (0): shutdown(): shutting down context
    AsioEndpointContext (0): shutdown(): context shut down
    AsioEndpointContext (0): shutdown(): shutting down context
    AsioEndpointContext (0): shutdown(): context shut down
    [2014-Jan-09 04:40:57] RDP (0): ------ END ACTIVE CONNECTION ------

    My problem is that the "proxy" is the proxy set up by my 3G configuration so, I tried connecting to the remote resources through my work wifi and I get the following:
    [2014-Jan-14 16:58:13] RDP (0): ----- BEGIN ACTIVE CONNECTION -----
    [2014-Jan-14 16:58:13] RDP (0): Final rdp configuration used: memory bookmark [
    label 
    hostname DIAZSERVER
    port 3389
    loadbalanceinfo 
    ui.swapmousebutton false
    remote.program ||chrome
    remote.workingdirectory 
    remote.name Google Chrome
    remote.args 
    rail true
    soundmode 0
    connect_to_console false
    redirectsdcard true
    performance_flags 134
    arc.sessionid 0
    anonymous_username 
    authentication_level 2
    use_redirection_server_name false
    username Administrator
    gateway [
      host = DIAZSERVER
      port = 443
      bypass = false
    connect info[
      hostnames = [localhost]
      gatewayHost = DIAZSERVER
      gatewayPort = 443
      routingToken = Cookie: mstshash=Administrator
      redirectionGUID = 
      proxyHost = 
      proxyPort = 0
      sessionId = -1
    [2014-Jan-14 16:58:13] RDP (0): Not using any proxy
    [2014-Jan-14 16:58:13] RDP (0): Protocol state changed to: ProtocolConnectingNetwork(1)
    AsioEndpointContext (0): startup(): starting up down context
    ASIOSocketAdapter (9): handleResolve(): boost error: Host not found. Please provide the fully-qualified name or the IP address of the host.. instance: 0x5d474090
    RpcOverHttp (9): Stream error in endpoint 0x5d46b678 : Unable to connect to remote PC. Please provide the fully-qualified name or the IP address of the remote PC, and then try again.
    [2014-Jan-14 16:58:17] RDP (0): Error message: Unable to connect to remote PC. Please provide the fully-qualified name or the IP address of the remote PC, and then try again.
    [2014-Jan-14 16:58:17] RDP (0): Error message: Unable to connect to remote PC. Please provide the fully-qualified name or the IP address of the remote PC, and then try again.
    [2014-Jan-14 16:58:17] RDP (0): Protocol state changed to: ProtocolDisconnected(8)
    ASIOSocketAdapter (9): handleResolve(): boost error: Host not found. Please provide the fully-qualified name or the IP address of the host.. instance: 0x5d445158
    RpcOverHttp (9): Stream error in endpoint 0x5d49fa30 : Unable to connect to remote PC. Please provide the fully-qualified name or the IP address of the remote PC, and then try again.
    [2014-Jan-14 16:58:17] RDP (0): Error message: Unable to connect to remote PC. Please provide the fully-qualified name or the IP address of the remote PC, and then try again.
    [2014-Jan-14 16:58:17] RDP (0): Disconnect initiated by client
    [2014-Jan-14 16:58:17] RDP (0): Error message: Unable to connect to remote PC. Please provide the fully-qualified name or the IP address of the remote PC, and then try again.
    AsioEndpointContext (0): shutdown(): shutting down context
    AsioEndpointContext (0): shutdown(): context shut down
    AsioEndpointContext (0): shutdown(): shutting down context
    AsioEndpointContext (0): shutdown(): context shut down
    [2014-Jan-14 16:58:17] RDP (0): ------ END ACTIVE CONNECTION ------
    Now, I know the host can be resolved because: if I connect to the same host but on a full remote desktop (as opposed to just RemoteApp on it) I have no trouble either through 3G OR through my work connection.
    Moreover, I also tried directly inputting the IP as opposed to the web address of my server, I get the same error, that is the Remote Resources tab is able to access the feed (because it shows the available RemoteApps) but when I click an app it says it can't
    find the Host, here's the log for the connection directly to the IP address/rdweb/feed/webfeed.aspx :
    [2014-Jan-14 17:09:27] RDP (0): ----- BEGIN ACTIVE CONNECTION -----
    [2014-Jan-14 17:09:27] RDP (0): Final rdp configuration used: memory bookmark [
    label 
    hostname DIAZSERVER
    port 3389
    loadbalanceinfo 
    ui.swapmousebutton false
    remote.program ||chrome
    remote.workingdirectory 
    remote.name Google Chrome
    remote.args 
    rail true
    soundmode 0
    connect_to_console false
    redirectsdcard true
    performance_flags 134
    arc.sessionid 0
    anonymous_username 
    authentication_level 2
    use_redirection_server_name false
    username administrator
    gateway [
      host = DIAZSERVER
      port = 443
      bypass = false
    connect info[
      hostnames = [localhost]
      gatewayHost = DIAZSERVER
      gatewayPort = 443
      routingToken = Cookie: mstshash=administrator
      redirectionGUID = 
      proxyHost = 
      proxyPort = 0
      sessionId = -1
    [2014-Jan-14 17:09:27] RDP (0): Not using any proxy
    [2014-Jan-14 17:09:27] RDP (0): Protocol state changed to: ProtocolConnectingNetwork(1)
    AsioEndpointContext (0): startup(): starting up down context
    ASIOSocketAdapter (9): handleResolve(): boost error: Host not found. Please provide the fully-qualified name or the IP address of the host.. instance: 0x5d372f28
    RpcOverHttp (9): Stream error in endpoint 0x5dd6b168 : Unable to connect to remote PC. Please provide the fully-qualified name or the IP address of the remote PC, and then try again.
    [2014-Jan-14 17:09:31] RDP (0): Error message: Unable to connect to remote PC. Please provide the fully-qualified name or the IP address of the remote PC, and then try again.
    [2014-Jan-14 17:09:31] RDP (0): Error message: Unable to connect to remote PC. Please provide the fully-qualified name or the IP address of the remote PC, and then try again.
    [2014-Jan-14 17:09:31] RDP (0): Protocol state changed to: ProtocolDisconnected(8)
    ASIOSocketAdapter (9): handleResolve(): boost error: Host not found. Please provide the fully-qualified name or the IP address of the host.. instance: 0x5d378de0
    RpcOverHttp (9): Stream error in endpoint 0x5e9cc1f0 : Unable to connect to remote PC. Please provide the fully-qualified name or the IP address of the remote PC, and then try again.
    [2014-Jan-14 17:09:31] RDP (0): Error message: Unable to connect to remote PC. Please provide the fully-qualified name or the IP address of the remote PC, and then try again.
    [2014-Jan-14 17:09:31] RDP (0): Disconnect initiated by client
    [2014-Jan-14 17:09:31] RDP (0): Error message: Unable to connect to remote PC. Please provide the fully-qualified name or the IP address of the remote PC, and then try again.
    AsioEndpointContext (0): shutdown(): shutting down context
    AsioEndpointContext (0): shutdown(): context shut down
    AsioEndpointContext (0): shutdown(): shutting down context
    AsioEndpointContext (0): shutdown(): context shut down
    [2014-Jan-14 17:09:31] RDP (0): ------ END ACTIVE CONNECTION ------
    I'm really puzzled here, I've tried checking if ports where open, and ports 443 and 3389 are wide open, I don't know what else it could be.

  • Entire JDBC communication stopped if problem with one single JDBC interface

    Hello,
    Will the entire JDBC communication stopped if problem with one single JDBC interface?
    Thanks,
    Soorya.

    hi surya,
    this will happend if u use maintain order at runtime at interface determination.
    just uncheck this option if u dont neet EOIO.
    if you are getting the problem if u r going for EO then the problem might be using same JDBC channel for all interfaces.
    if each interface is expected with a high load then it better to go for dedicated channels for interfaces.
    like INTERFACE A should use JDBC A channel and INTERFACE B should use JDBC B channel.
    Thanks & Regards,
    Rama krishna

  • JDBC communication stopped if problem with one single JDBC interface

    Hello,
    Can you please explain this phrase
    "JDBC communication stopped if problem with one single JDBC interface"
    THanks,
    Soorya

    If you are having a problem with a JDBC interface (lets consider this to be a communication channel) then the communication is stopped (via that channel) (only in the case of EOIO).
    Hope this clarifies.
    Cheers,
    Sarath
    Award if helpful.

  • Problem with SQL connection and a Collection

    hi all,
    I have two problems with sql...
    1. how can I assign the values of a resultset to a collection?
    2. how can I close the sql connection, because when I close the statement and connection error shows me in the resultset
    thanks!

    Hello Pablo,
    RetrivingResults In Collection:
    1)   use getObject method, and assign it to collection.
              Collection c_obj=new ArrayList();
             while(rs.next())
                    c_obj.add(rs.getInt(Project_ID), rs.getString(Project_Name));
    Closing ResultSet
    2)               The close() methos of ResultSet closes the ResultSet object, like bellow
                    ResultSet rs = stmt.executeQuery("SELECT a, b FROM TABLE2");
                    rs.close(); //Closes the result set

  • 8900 printer changed black cart. error code problem with printer system

    Changed black cartridge in 8900 series all in one printer error message says trouble with print system call HP.  Have removed and reinstalled catridge still same error message. HELP!!!!!

    Hi @melvinc 
    Welcome to the forums
    I read about the issue you are facing on your printer, as it's now showing a problem with the ink system. I cannot locate a "8900" printer, could you possibly have the Officejet 8600? If so, please try out the steps from the guide below. If you reach a step where it asks to replace the printhead or printer, call us directly to see what your replacement options are with HP.
    A 'Problem with Ink System' Error Message Displays on the Control Panel or Computer During Setup
    Please call our technical support at 800-474-6836. If you live outside the US/Canada Region, please click the link below to get the support number for your region. http://www8.hp.com/us/en/contact-hp/ww-phone-assis​t.html
    Have a great day
    R a i n b o w 7000I work on behalf of HP
    Click the “Kudos Thumbs Up" at the bottom of this post to say
    “Thanks” for helping!
    Click “Accept as Solution” if you feel my post solved your issue, it will help others find the solution!

  • Could not complete the ... command because of a problem with the filter module interface

    I just reinstalled Photoshop CS6. I'm running OS X 10.8.2 .
    I use the Nik plugins suite, and reinstalled them as well. Now whenever I try to use one of those plugins I get the error "Could not complete the ... command because of a problem with the filter module interface."
    The reinstallation was a bit of a struggle due to issues on Adobe's end, and I am hesitatnt to just dive in and reinstall without wome idea as to what might cause these errors.
    Any insight appreciated.
    Stu

    Not sure I know what you mean by "disabling the Nik filter folder".
    I have the latest updates for the Nik filters and they are compatible with CS6.
    Since yesterday I tried uninstalling the Nik filters, manually locating and removing every file related to Nik/Nik Software, redownloading the Nik installers, uninstalling/reinstalling Photoshop, and reinstalling the Nik filters. Same result.
    I am pretty sure this is something on the Photoshop end, but am not sure what to do next. Maybe repeat the above and use the Creative Suite cleaner before reinstalling?
    Stu

  • Can't use certain filters- "problem with the filter module interface"

    Hello,
    I frequently use the BPelt Flatten and Multifill plugins and they have always worked perfectly until today. Now I get the following error: "Could not complete the [Multifill/Flatten] command because of a problem with the filter module interface."
    I use Photoshop CS6 Extended with the Creative Cloud membership, and just recently updated to version 13.1.1 x64. I believe this may be related, as the plugins worked before the update and nothing else has changed.  Any recommendations on how to fix this? Is it possible to undo  the update?

    Usually this means a bug in the third party plugin that you are using.

  • 140063685933 this is the receipt no Apart of two purchase there all rest I never received was a problem with the system they couldn't be download and naw you are charging me  Haw unprofessional is that and more than an hour can't find how to get to custom

    140063685933 this is the receipt no
    Apart of two purchase there all rest I never received was a problem with the system they couldn't be download and naw you are charging me
    Haw unprofessional is that and more than an hour can't find how to get to customer service to correct the mistake
    Just so fed up will never ever pitches anything waiting of time and money  

    Apple is not here. Apple does not answer questions here. There are only volunteer users here.
    The charge to your credit card takes place before you download the app.
    If you are having problems downloading the apps that you bought, you will need to explain the issue in detail if you wish someone to help you.

  • URL problems with SQL Server Reporting Services 2012 with wildcard SSL certificate

    Hi,
    I have single server, domain member, with SQL Server 2012 SP1 Reporting Services.
    I am trying to get work with url: https://reports.mydomain.com
    I have valid wildcard certificate (*.mydomain.com) implemented and configured URLs in Configuration Manager.
    https://reports.mydomain.com/ReportServer - works fine
    https://reports.3pro.hr/Reports/ - I got error:
    The underlying connection was closed: Could not establish trust relationship for the SSL/TLS secure channel.
    In rsreportserver.config I have:
    <Add Key="SecureConnectionLevel" Value="2"/>
    When looking my ReportServerService_date.log file I have something like:
    configmanager!DefaultDomain!3f4c!03/10/2013-20:24:34:: i INFO: Using report server internal url https://localhost:443/ReportServer.
    configmanager!DefaultDomain!3f4c!03/10/2013-20:24:34:: i INFO: Using report server external url https://serverhostname:443/ReportServer.
    configmanager!DefaultDomain!3f4c!03/10/2013-20:24:34:: i INFO: Using url root https://reports.mydomain.com/ReportServer.
    configmanager!DefaultDomain!3f4c!03/10/2013-20:24:34:: i INFO: Using report server internal url https://localhost:443/ReportServer.
    configmanager!DefaultDomain!3f4c!03/10/2013-20:24:34:: i INFO: Using report server external url https://serverhostname:443/ReportServer.
    configmanager!DefaultDomain!3f4c!03/10/2013-20:24:34:: i INFO: Using url root https://reports.mydomain.com/ReportServer.
    Also, error shown in log file:
    appdomainmanager!ReportManager_0-2!4c50!03/10/2013-20:24:53:: e ERROR: Remote certificate error RemoteCertificateNameMismatch encountered for url https://localhost/ReportServer/ReportService2010.asmx.
    ui!ReportManager_0-2!4c50!03/10/2013-20:24:54:: e ERROR: System.Net.WebException: The underlying connection was closed: Could not establish trust relationship for the SSL/TLS secure channel. ---> System.Security.Authentication.AuthenticationException:
    The remote certificate is invalid according to the validation procedure.
    Btw, is there a way to delete/disable access using https://localhost and/or servername (not FQDN) since SSL will not work in this way for me, and I want access only by full url - https://reports.mydomain.com , not localhost ..
    -- Hrvoje Kusulja

    I spent one of my 4 free support incidents with Microsoft (part of MSDN subscription) this year to get this investigated.  The tech support person helped me through several issues but had to leave to attend some training, and I got past the last hurdle
    before she called me back.  Here are the steps that resolved this issue for me.  I know for sure that step 5 was necessary.  Step 1 may not apply to you, and steps 2-4 may or may not have been necessary (they didn't immediately fix the issue,
    but I didn't roll them back either so they may have been necessary.)
    Step 1:
    Ensure you are editing the correct rsreportserver.config file.  I had been making changes to a file that was installed in C:\Program Files\Common Files\microsoft shared\Web Server Extensions\14\WebServices\Reporting, but that was a rsreportserver.config
    file for some sharepoint integration that I'm not using.  The correct path on my system was E:\MSRS11.MSSQLSERVER\Reporting Services\ReportServer\rsreportserver.config, but yours may vary. If you can't figure it out, look in the registry under HKEY_LOCAL_MACHINE\SOFTWARE\Microsoft\Microsoft
    SQL Server\MSRS11.MSSQLSERVER\Setup in the key named SQLPath, and then go to the ReportServer subdirectory of that path.
    Step 2: 
    In rsreportserver.config, ensure that SecureConnectionLevel is set to the value 3.  Was set to 0 in my configuration.  Corrected line in your rsreportserver.confiog file should look like:
    <Add Key="SecureConnectionLevel" Value="3"/>
    Step 3:
    In rsreportserver.config, add the correct value to the <URLRoot> element (which already exists in the file.)  In my configuration, this value was blank.  The value should be the fully qualified path to your report server, with a hostname that
    is valid for your certificate.  For example, if my cert matches *.mydomain.local:
    <UrlRoot>
    https://myserver.mydomain.local/ReportServer
    </UrlRoot>
    Step 4:
    Ensure that your certificate exists in Trusted Root Certification Authorities in certmgr for the local machine.  I had the certificate installed as a Personal certificate for the local machine, which I still think was correct (the certificate wasn't actually
    the problem and worked correctly for Report Server, and the failure was caused by SSRS incorrectly making a https request to a localhost URL), but she had me remove the certificate from Personal and add it to Trusted Root Certificate Authorities.  That
    broke things and the cert was no longer listed as a cert I could bind to, so we then copied it so it existed in both Personal and Trusted Root Certificate Authorities.  This is how I left it, not sure if that was necessary.
    Step 5:
    This was the fix that finally got things to work. In rsreportserver.config, add the same value to the <ReportServerUrl> element (which also already exists in the file) that you added in step 3.  In my configuration, this value was also blank.
    The corrected value should be the same as in step 3, for example:
    <ReportServerUrl>
    https://myserver.mydomain.local/ReportServer
    </ReportServerUrl>
    Then restart your report server (stop & then start in Report Server Configuration Manager), and the problem should go away.  At least it did for me.
    Good luck!

  • Problem with SQL,udfs & procedures

    I have couple of problems with my database. Please suggest solution.
    We are basically a web product With a Quite large Database
    1. I am using functions both User Defined and Built in Functions in
    SQL Statement. I want to optimize the query how do i do it.
    why the usage of function in sql statements suppresses,the
    usage of indexes internally. How to forceable make use of
    the index even though function is used.
    2. Whenver The Client makes a request to the Database server with a
    Sql Query What are the steps we can take at the
    client side to enhance the performance of the Query.
    (i.e the Data Request ). How to optimize the usage of CPU at
    client site?
    3. what is the increase in the performance ration by having
    separate table spaces for user data,system data and indexes.
    4. Why the procedures are getting invalided
    after some time. The procedure is
    not getting executed at the front end.
    Once the procedure is getting invalidated.
    However even though the status of the
    procedure is invalid the same is getting
    executed at the back end.
    Can anybody help me
    Request for reply ASAP.
    Regards
    Koshal
    null

    1. In Oracle 8i, one can create function-based indexes, where instead of indexing a column, one can index upper() of that column.
    2. Optimizing client performance is trickier. One can tune the queries being
    submitted by the client, but if getting the first row back -- which is how response time is generally perceived -- set the OPTIMIZER_MODE parameter in init.ora to FIRST_ROWS.
    3. There is minimal benefit to having data, index, rollback, and temp tablespaces all separated unless all the datafiles for each tablespace reside on different disks (data on disk 1, index on disk 2, etc). It's recommended regardless, but unless the files are on separate volumes, there won't be a great performance benefit.
    4. A procedure is invalidated whenever DDL is issued against any object that that procedure depends upon. For example, if you add a column to a table, any procedures which reference that table will be invalidated. Any procedures which reference views which reference that table will be invalidated, because the view will be invalidated. It's best to run a compile script which looks for and attempts to recompile any invalid objects on a daily basis.
    Adam

  • Problem with FWSM and L3 interface in same switch

    I have two 6513s with an 802.1q trunk connecting them. Each switch has redundant Sup720s running in Native mode, IOS ver 12.2(18)SXF (they were initially running SXD3). A FWSM (ver 2.3(3), routed mode, single context) is in each switch, setup in failover mode.
    I can not get a PC, in a vlan that has the layer 3 interface defined on the switch with the active FWSM in it, to communicate with devices "behind" the FWSM. If I move the layer 3 configuration for that vlan to the other 6513, everything works fine.
    The MSFCs are on the inside of the firewall, they have a layer 3 interface configured in the same vlan as the FWSM "inside" interface. Several "same security level" interfaces are defined on the FWSM and used to protect server farms. I am using OSPF on the MSFCs and FWSM and the routing table is correct.
    The FWSM builds connections for attempts made by the PC with the layer 3 interface defined on the same switch as the active FWSM just fine, so this is not a FWSM ACL problem.
    A ping of the FWSM "inside" interface from a PC with the layer 3 interface defined on the same switch as the active FWSM fails, even though debug icmp trace on the FWSM shows the request and the response. A packet capture, using the NAM-2, shows only the request packets. I have captured on the common vlan and the FWSM backplane port channel interface.
    Just to add to the confusion, if I capture in the same places, but do the ping from a PC that is in a vlan with the layer 3 interface defined in the 6513 that does not contain the active FWSM, which works fine, I see the request and reply on the common vlan capture, but only the request on the port channel capture.
    This problem has been there from the beginning of this implementation and has not changed with IOS and FWSM software upgrades. I have experienced this with any and all vlans that I tried to define the layer 3 interface for on the switch with the active FWSM. I have MLS turned on.
    If anyone else has experienced this and solved it, or knows what is going on, I would appreciate any insight.
    Thanks.
    Keith

    I will have to get setup to record more data, but I do know the FWSM showed a ping request and a ping reply at the "inside" interface.
    I believe my problem is related to the IOS command "firewall multiple-vlan-interfaces" which I put in place to allow IPX traffic to be brought around the FWSM. The little documentation that there is for this command, states that policy routing may need to be implemented to prevent ip packets from going around the firewall. I do not have any policy routing in place.
    I also do not have any active layer three interfaces defined for any of the vlans assigned to the firewall except the "inside" interface. So my resoning was that I did not need to be concerned about ip packets having a way around the FWSM. My suspicion is that this command and the fact that I have mls on is causing some type of a problem which results in the packet being "lost" when it needs to be going through the MSFC in the switch with the active FWSM to get to the PC. Hopefully that makes some sense.
    Do you have any idea where better documention on using the "firewall multiple-vlan-interfaces" may be, or a better explanation of all that is happening inside the switch when that command is used?
    Thanks.

Maybe you are looking for

  • HT1455 What if my computer will not start up in safe mode?  What next?

    What is the remedy for a MacBook that will not start up in safe mode?  The gray apple icon and progress wheel appear, I let go the shift key and the whole thing shuts off again.  Please help.  Thank you.

  • FATAL ERROR document format: structure 'STATEMENT'

    Hi experts, I've a scenario IDOC to JDBC, give me the error: FATAL ERROR document format: structure 'STATEMENT' I don't understand becausse payload is OK: <?xml version="1.0" encoding="UTF-8" ?> - <ns0:MT_MATERIALES xmlns:ns0="http://idom.com/arteche

  • How do I print preview?

    I have powerpoint on my macbook pro, and i want to make it so there is three slides to a page with extra space to the right so that i can make notes. But I dont see a place for me to preview what i am wanting to print so that i can adjest it. Please

  • I am unable to delete history - this started yesterday

    I have tried all options that I am aware of - checked your FAQ's and tutorials. I am unable to delete - system can't handle my FB traffic. what have I missed? up until yesterday, even after deleting by your options, I have had to manually delete. Ple

  • Customize Sourcing Cockpit  in SRM 5.0

    Hi experts, i'd like to know how is possible to customize in SRM 5.0 (back Ecc6.0, Classic Scenario) the Buyer' Sourcing Cockpit. Is there a particular workflow? Is the operational purchaser the right role? Thanks Regards