Production Order - Trigger won't Auto Refresh

2007A PL49 - Just upgraded from 2005A
I have the following query set in a UDF on the Production Order.
SELECT T1.PriceAfVAT
FROM ORDR T0 INNER JOIN RDR1 T1 ON T0.DocEntry = T1.DocEntry
WHERE T1.ItemCode = $[$-6.0.0] and T0.DocNum = $[$-32.0.0]
The query wasn't working after the upgrade from 2005.  I had to change the query to include the negatives "-" in the WHERE clause.  Once I did this the query was working fine.  However, now that the query is working it doesn't refresh automatically.
My settings are as follows:
Auto Refresh When Field Changes is selected
The field is Production Order Origin Number
Display Saved User-Defined Values is selected
If I place my cursor in the UDF and hit Shift+F2 the query is executed and pulls in the correct data.
How do I get the Auto Refresh functionality to work properly?
Note: other triggers are working correctly after the upgrade.

The problem is probably you selected Auto Refresh Field Changes as the same field in the Where clause.  If you could find any other fields to select, it should work.
Thanks,
Gordon

Similar Messages

  • Production order confirmation cancellation with auto goods receipt

    Hi expers,
    I've got a production order using backflush and Auto GR for last operation(Control Key with Auto GR Tick). After the confirmation operation had been done,the end user cancelled the goods receipt using T-code/MvT:MIGO/ 102 by mistake,and then using T-code CO13 cancelld the confirmation.Now  the delivered qty of the production order is negative, the material document generated by using MIGO/102 by mistake can't be cancelled, i also tried to do a migo with 101,the abap program dump.  the production order can not even be viewed by using CO03.The ABAP program dump.
    Any help would be much appreciated!

    Here is some of the dump message:Runtime errors DYNPRO_FIELD_CONVERSION
    Short text  Conversion error .
    Error analysis
    The program has been interrupted and cannot resume. 
    Program "SAPLMIGO" attempted to display fields on screen 0200. 
    An error occurred during the conversion of this data.
    How to correct the error
    There was a conversion error in the output of fields to the screen.
    The formats of the ABAP output field and the screen field may not match.
    Some field types require more space on the screen than in the ABAP
    program. For example, a date output field on the screen requires two
    more characters than the corresponding field in the ABAP program. When
    the date is displayed on the screen, an error occurs resulting in this
    error message.
    Screen name.............. "SAPLMIGO"
    Screen number............ 0200
    Screen field............. "GOITEM-WEMNG"
    Error text............... "FX015: Sign lost."
    Other data:

  • Goods receipt not marked for production order trigger from sales order

    Hi all,
    In MTO scenario, where requirement trigger from Inquiry -> Quotatation -> Sales Order -> Plan Order -> Production Order, goods receipt indicator in production order was not checked if requirement is triggering from sales order, however it is ticked if requirement trigger from inquiry, therefore we are not able to do confirmation. Appreciate if anyone able to assist us as soon as possible.
    Thanks in advanced.

    Hi,
    I understood that---
    If u r creating Sales order directly without Quotation u r  not able to do the GR.
    If u create from Quotation, u r able to do GR. right?
    I think, Problem with Settlement. Please Look into that.
    Kiran.

  • Outlook 2007 won't auto refresh the internet calendar

    HI, 
    I subscribed a web ical with the instruction (File > Account Settings and then the Internet Calendars
    Tab, then click New and enter the path)
    for outlook 2007:
    the new calendar could display all the events correctly after set up, but it won't update the new event anymore automatically. even I close and re-open the outlook, it still not update, the last update time is the time when set up this calendar. 
    for outlook 2010, i tested, it can auto update the internet calendar when open the outlook everytime.
    is this the problem with outlook 2007?
    (I don't want user to press F9 to refresh everytime) 
    and i also tried to add X-PUBLISHED-TT property in the iCal file and it seems not working also
    Please help ! Thanks !

     Hi
    zhenyun,
    Sorry for Late reply, if you are still facing same
    issue then you should go for some kind of auto refresh plug-in or Add-in. After a bit search on Google, I found some of them called
    “Zoho” and “Vtiger”.
    As I am not much sure about this Add-in, you have to read about
    its functionally first by visiting given link.
    http://www.zoho.com/crm/help/outlook/using-plug-in-for-microsoft-outlook.html
    https://wiki.vtiger.com/vtiger6/index.php/Outlook_Plugin
    Hope, this link and Plug-in will give you some relax.
    Thanks
    Clark kent

  • FireFox won't auto-refresh specific site, other browsers do. How can I get FF to auto-refresh?

    I have a Help Desk application (everything HelpDesk) with a web interface. I keep my queue screen open so I can see new tickets come in and check status of existing tickets. FireFox does not auto-refresh this queue page so that new items or status changes show up. The page must be manually re-loaded in FireFox. However, other browsers (Chrome, IE, Safari) auto-refresh the queue page just fine. How can I get FireFox to auto-refresh this page?

    See:
    *Firefox/Tools > Options > Advanced > General : Accessibility : [ ] "Warn me when web sites try to redirect or reload the page"
    The setting in "Tools > Options > Advanced > General" is meant as an accessibility feature, as you can see by the label of that section, so that people with disabilities or people who use screen readers do not get confused and is not meant as a safety protection to stop redirecting.
    See also:
    *https://support.mozilla.com/kb/Options+window+-+Advanced+panel#General_tab
    *http://kb.mozillazine.org/accessibility.blockautorefresh
    *http://kb.mozillazine.org/Accessibility_features_of_Firefox

  • Firefox 13.0+ bookmarked RSS feeds won't auto refresh

    Hello. Since Firefox 13.0 and above (up to the latest 17 pre alpha nightly) the feature that allows your bookmarked RSS feeds to be automatically updated is GONE. Previously popular browser.bookmarks.livemark_refresh_seconds (I had to enter this value) either broken or does not exist in the latest FF versions, it is simply does not work.
    I've tried everything, starting from disabling add-ons to safe mode but nothing helps in solving this problem. Could you please tell if this is a bug or this feature is no longer supported in Firefox so I can stop bothering and switch to another browser
    Best Regards

    Yes, you now need to refresh the live feed items manually because live feeds now work as regular bookmarks.<br />
    Only the initial loading is automatic the first time you open a live feed bookmark.
    See:
    *http://mxr.mozilla.org/mozilla-release/source/toolkit/components/places/Database.cpp#1804

  • To restrict Issue for production than planned qty in production order

    Hi Experts,
    In my scenario, the production staff will prepare production order and right click in production order document and select "Issue Components" option to Issue raw materials for production floor. After issuing the raw materials to production floor closes the "Issue for Production" document and now we have "Production Order" document open in screen. When he again select "Issue Components" option and issues the raw materials once again. Materials are issued once again wrongly. This happens since the production order document is not getting refresh after "Issue for Production" document is done.
    Is there any way to restrict issue of raw materials than the planned qty.?
    I have tried lot of ways to restrict this through SP. Please revert me an solution to this issue.
    The procedure should trigger immediately when the "Issue Components" option is selected second time (If the raw materials are issued in full in first time itself). And it should allow only the qty which is to issued to production order qty (if they issue part issue to production order)
    Thanks in advance
    Raja.S

    Hi Neetu,
    Thanks for your quick response. I have tried this query. But it is not blocking the issue for production document even the raw materials are issued already for the production order.
    I'll explain my work flow again. The Production staff will prepare production order and then release the same and update the production order after changing  the status for "Release". Then he will right click the Mouse button and select "Issue Components" option and perform the Issue for Production process. He will issue the required raw material completely in one shot and add the Issue for Production document.
    After adding the Issue for Production document he will close that document and now we will be in Production order document. Now our production order document will not get refreshed. Now the Production staff go for "Issue components" option, then it should not allow him to issue the components once again. But it is allowing him to issue components any number of times. there is no control.
    If we browse the production order document to previous record and browse back to the same record then my Production order document get refreshed and now we can control the issue. But what should i do to control in the earlier case. Since they want to perfrom lot of production order, there is a chance to issue components for same production order more than one time before the production order document get refreshed.
    Please provide me the SP to control this scenario.
    Thanks in advance.
    Raja.S

  • Add inspection characteristics to production order created via CO07

    Hi, all.
    We're creating production orders to perform production rework on assemblies using transaction CO07. 
    We have a requirement to inspect and make a usage decision on the reworked assembly.
    Since there is no material at the header level for CO07 orders, the system isn't allowing us to do an inspection because it has no material master QA view to reference.  Although the control key is marked for in-process inspection, the production order still won't allow it.
    I can't add "unplanned inspection characteristics", not can I manually create an inspection lot using QA01. 
    Is there a way to manually force in an inspection for an operation on a CO07 order?
    Thanks.
    Sarah

    Hi,
    We cannot do a inspection for a production order unless it has material assigned to it and the material got QM inspection type relevant to that.
    regards,
    Lenin. A

  • Auto-sleep won't work when web pages auto-refresh

    Dear Apple,
    Around 4 years ago, I noticed that my computer stopped going to sleep. I first noticed it shortly after adopting Gmail for my email platform and was subsequently able to isolate the issue down to Gmail and other websites, such as Huffington Post, which auto-refresh. Apparently, any website that auto-refreshes at shorter intervals than the auto-sleep is set to kick in, prevent the computer's auto-sleep function from activating.
    I have spoken at length with AppleCare about this issue and understand that this is "by design." For instance, we wouldn't want the computer to constantly go to sleep while watching a movie or downloading and conversely, if we are actively working at our computers it's nice that Gmail auto-refreshes and keeps us appraised of incoming mail. However, since the vast majority of users now leave their browsers with multiple tabs open and due to the fact that more and more websites now auto-refresh, the auto-sleep function has become outdated and non-functional. While users can always manually put their computers to sleep, everyone at some time or another forgets to do so. This is exactly why computers are supposed to auto-sleep in the first place. Aggregated across millions of users, this results in a huge waste of electricity.
    I've been writing/calling Apple (through AppleCare and the online feedback form) about this issue for 4 years now. I keep hoping that with each operating system release, some sort of "smart auto-sleep" function will be incorporated that will recognize when websites auto-refresh and still allow auto-sleep to kick in. Unfortunately, this does not appear to be the case in Lion.
    I work in the energy efficiency field, specifically in lighting, and care deeply about this issue. I consider Apple to be an industry leader on this issue as well. I'm not familiar with the technical side of this issue, but I assume that with the right type of programming, the operating system could override a webpage's auto-update feature and activate auto-sleep, while not interfering with functions where a user would not want the computer to go to sleep, such as watching a movie. With Lion, Apple has focused its energy on making the computer adjust to the user,rather than the user adjusting to the computer. Yet, in this case, it appears to be the other way around.
    It is time for Apple to update the auto-sleep function so that it takes into account websites that auto-refresh. When I set my computer to auto-sleep after so many minutes, I want it to do so, regardless of whether I have a browser with auto-updating websites open. Apple must take this issue seriously, as the wasted electricity is too important to ignore any longer.
    Sincerely,
    An Energy-Conscious User

    I am obviously talking to Apple AND I posted this letter here, because a lot users seem confused about why their computers won't sleep. Even most AppleCare reps are confused. In the past, I couldn't find much in the way of explanations pointing to this issue, so I thought I post it here in case other people are looking for an explanation.
    The auto-sleep function was built before websites auto-updated and needs to be updated to accomodate them. For the average user, it doesn't make sense for the computer not to sleep just because Gmail is open. Just because some website auto-refreshes in my browser, doesn't mean I never want my computer to sleep. By the same token, if I wanted to turn off auto-sleep I could easily do so from within Energy Saver Preferences. The two should be independent, so the user has the choice.
    Why should I have to close my browser every time I walk away from my computer in order for it to sleep? I've acknowledged that in certain circumstance it makes sense for the computer not to auto-sleep: watching a movie, uploading, etc, but Apple has already accounted for those instances because the computer does not auto-sleep when those programs are running. All I'm suggesting is making the auto-sleep mechanism more sophisticated so that it isn't overridden by websites auto-refreshing. 
    Why the negative attitude, dwb? Based on the amount of time you spend in these discussion forums, you obviously never turn your computer off, so this doesn't really affect you. Maybe it's time to step outside and get some fresh air?

  • Auto goods receipt against production order

    is it possible to do auto goods receipt against production order of (material with serial number)
    if not please suggest me solution
    please also tell me possibility of enchancement
    for goods receipt against production order
    sunil

    Hi
    If you check mark the auto goods receipt in the control key used in the work center used in the routing then you can have auto goods receipts posted for the production order against a confirmation.
    Rathnakar

  • OM: Disable auto refresh check box in Quick Sales Order Form

    hi,everyone
    In screen [Quick Sales Order Form],
    we want to let the auto refresh check box always be checked and can not be updated with Form personalize.
    I didn't find the item in this form,
    and i konw that there is a value which defined in the Profile : [OM: Quick Sales Order Form: Auto Refresh](ONT_QUICK_OE_AUTO_REFRESH).
    Can anyone give me some suggestions?
    thx for ur help.

    hi,Pradeep
    Thanks for your reply.
    Actualy,the profile "OM: Quick Sales Order Form: Auto Refresh" has been setted into 'Line' firstly as we want to auto-refresh order lines.
    So the 'auto refesh' checkbox is checked with default value in the screen,
    but the order line would not be auto-refreshed when user uncheck the checkbox manually.
    So we want to disable or invisible the 'auto refesh' item in the screen with form personalize,
    the problem is i can not find the item or the block in the form.
    Or is there any suggestions to archive this?
    Can you please help me?
    Thanks,
    Leno
    Edited by: Leno Sun on 2013/05/07 19:35

  • Auto-Refresh and Order By for view accessors

    Hi,
    We have set auto-refresh to true on a VO(LovVO) in shared AM and used the same to create an lov in another VO. Now if we have Order By in LovVO then we get the exception:
    ORA-29983: Unsupported query for Continuous Query Notification
    This is because of the Order By clause. When i remove the order by then there is no error. But we need the data to be ordered. So I have added the below code LovVOImpl.java executeQueryForCollection method:
    if(this.getSortBy() == null){
    this.setSortBy("Name");
    super.executeQueryForCollection(object, object2, i);
    and this is working fine. Is there any other declarative solution for this scenario?
    I tried setting the order by in the view accessor but that also appends to the sql query and throws the above error.
    Thanks
    Thiru

    Please see http://download.oracle.com/docs/cd/E11882_01/appdev.112/e17125/adfns_cqn.htm#CHDGEBFH. Look like OREDER By is supported only in Best-Effort mode.
    When you call .setSortBy("Name"), it happens in memory not part of SQL, apparently that works

  • Auto Production Order Settlement

    Dear experts,
    Please advise how to implement the auto production order settlement (configuration, exit)?
    i need to automatically carry out the settlement procedures (in the background?) as soon as the production order gets the 'TECO' status.
    I searched for similar question but not answered
    http://scn.sap.com/thread/463939
    Thanks for your kind suggestions in advance.
    Best Regards,
    Gary

    Hi Gary,
    What I meant here was, let's assume you have 10 plants where TECO would be done for Prod. Orders
    Assuming that you split the batch jobs based on the number of the open Prod. Orders in a plant and then have them run once a day to avoid excessive use of system resources.
    The program can be found with search string *CO88* in SE38.
    The settlement would happen for the Orders which has the TECO status as per the standard SAP design, only difference would be that the once having no changes would be ignored and with the newly TECOed Prod. orders would be considered for the settlement.
    Hope that helps!
    Varshal Kachole
    The SCN Rules of Engagement

  • Auto Production order for SFG

    Dear Experts...
    We release somany order for 1 fg.. I mean we relase 1 order for Finished goods and another  4 to 5 order for Semifinished goods..
    Is there any possiblity to auto release the SFG order while releasing the FG order...
    Pls reply....

    Hi Sri Ram,
    Normally to start the production of FG, we need the stock available for SFG.If there are many production orders to release then you can use CO05 (manually) or you can schedule a back ground job (automatically) using the program PPIO_ENTRY program.
    Regards,
    Rajarao.

  • VC reference char not auto-populating on Production Order

    Experts,
    I've created a reference char CAUFV_AUTYP & included it on my class 300. Intent is to influence certain behavior on the stand alone Production Order (CO01) configuration using VC (Header >> Configuration section).
    Expectation is that when a Production Order is created, the CAUFV_AUTYP will get defaulted to a value "10" (for Production Orders) & when that happens, I want the VC to enable certain things for me on the configuration screen. I'm trying to write a selection condition & a pre-condition using the value of CAUFV_AUTYP = 10.
    Problem - When I create a stand alone production order, I'm not seeing the CAUFV_AUTYP value auto populate to "10".
    Any ideas on this? I was hoping that even before the Production Order commit to the CAUFV table happens, it shud have been able to read the AUTYP=10 & populate on the production order.
    Thanks

    I don't know whether you can do so.  According to SAP help, you can only change BOM component (STPO table), task list operation (PLPOD), Sequence (PLFLD),  and PRT value (PLFHD).  You can put the object dependencies in BOM or routing. 
    You cannot just change any field in production orders (why would you want to change the field order category in the first place?).
    You can also change the sales order via VCSD_UPDATE table.  The object dependencies should reside in your configuration profile in this case.
    Rgrds,
    See the link for more detail.
    [http://help.sap.com/saphelp_erp60_sp/helpdata/en/92/58d455417011d189ec0000e81ddfac/frameset.htm]
    Edited by: ayethebing on Apr 17, 2011 3:37 PM

Maybe you are looking for

  • Cannot edit page

    I have a problem editing one page on my site. When I was publishing it the server connection was lost. Now no one can edit the page. There is no *.lck file nor do any users have a draft of the page. Contribute is not providing any error message; clic

  • Reading a text file from a remote host. Authentication required.

    Hi frnds, I have to read a text file "config.txt" from a remote host "HOSTNAME". File is shared in a folder - "FOLDER" . If the folder is shared with no password protection then it works. But if the folder is password protected the code is unable to

  • ITunes will not even open

    Okay, disregard my SN, because I'm really upset right now. iTunes has just decided on it's own that it's not going to function properly any more. This couldn't be worse because I have to leave for a 3 hour drive and I have no music now because this s

  • Frozen at apple and pc won't detect.

    My ipod mini 4gb is frozen at the apple icon, and my pc won't detect it. Because my pc won't detect it, I can't fix it with any of the tips on apples website. What should I do?

  • Problem with hierarchical queries

    Hi, I implemented (thx to jarola) sucessfully a report using a hierarchical view. It is nearly the same as in Tyler Muths blog: -http://tylermuth.wordpress.com/2009/02/26/hierarchical-query-to-unordered-list/- -select (level*20)-20 the_level ,(level*