Q Master Quick Cluster Problems

Has anyone else on Leopard successfully set up a quick cluster, and not had Compressor completely stop working after a day or so?
After re-installing Compressor for the third time i had a eureka moment where i thought what a minute it must be my firewall.
Sure enough qMasterd was set to Block Incoming Connections.
Compressor always works fine for a couple of days after reinstalling so i went back and deliberately set the Firewall to block Qmaster. But then Compressor stil worked.
Now that it's fine again i'm afraid to set up a quick cluster for fear that everything will go down the tubes.
It's like the Start Sharing button in QMAster should be called Destroy Compressor.

See if this is at all helpful.
Russ

Similar Messages

  • Strange behavior with Quick Cluster and one shared machine

    Hi, I've been struggling for a while with my compressor 4.0.7 distributed processing setup... Here is my configuration:
    1 Mac Mini running as a Quick Cluster with services (3 instances of compressor shared)
    1 Macbook Pro running Services Only (7 instances of compressor shared)
    1 Macbook Pro (much older) running Services Only (2 instances of compressor shared)
    All 3 systems are running Mavericks, but I had this same problem when all 3 were Mountain Lion.. Had to trash the app and all of the prefs in Library\Application Support\Apple Qmaster and Compressor and reinstall to get the app running on all of the upgraded machines, so a fresh start didn't fix this issue.
    The Mac Mini and the older Macbook Pro can see the cluster, submit jobs and are both utilized for rendering when jobs are submitted from the Mini or the older Macbook Pro
    The newer MBP can see the cluster in Share Monitor and in qadministrator, but cannot see any of the jobs in the history (the other Macbook Pro can see all details identically to the Mac Mini).  When a job gets submitted from this system it appears as "Not Available" on the Mac Mini share monitor and it only utilizes 1 local process to do the rendering, which stalls out after about 1 minute. Activity Monitor shows all 7 instances of compressord are running and not frozen but have no activity.
    Jobs submitted from the Mini and older MBP attempt to use the newer MBP for distributed rendering but stall out after about 30 seconds with a host error.  The shared volume never appears on the newer MBP. Qadministrator on the Mini can see the newer MBP and all of the listed services as available.
    Now here is the part that really blows my mind:
    After submitting a job to the cluster from the newer MBP, which will stall out and need to be cancelled as mentioned above; submitting a job from the mini will actually successfully use the services on the newer MBP. Share monitor on the newer MBP still does not display any jobs on the server cluster. Rebooting the newer MBP puts me right back in the "I won't play with those other macs" tantrum.
    Anyone else see this issue and have a fix for it? Workarounds are nice but this is very, very annoying when I get into crunch time.

    Do you have log files?
              - Prasad
              Chris Dempsey wrote:
              > We have 2 WebLogic 4.5.1 servers in a cluster with none of the Service
              > Packs installed. When a client uses the deployed entity beans or
              > servlets they work every other time. The times they do not work nothing
              > happens. No exceptions, no responses to the client ( i.e. HTTP 404s ),
              > nothing. I suspect something in the cluster setup since we do not have
              > these same problems on non-clustered entity beans or servlets. We have
              > made sure all the entity beans have the Shared Database flag set on and
              > added the delayUpdatesUntilEndOfTx false to the enviroment of the DD.
              > That didn't fix the problem. Any ideas?
              >
              > Thanks in advance,
              > Dallas Dempsey
              > DEM - Houston, TX
              

  • Quick Cluster no longer appears in drop down lists

    I haven't changed any settings, one day my cluster just disappears off all the lists it used to appear in (selecting which cluster to use in Compressor, Compressor Droplets and Shake)
    Now all that shows is "My Computer".
    The QuickCluster wasn't anything special, it was just a local cluster with 16 instances (all on my own computer) to take advantage of the many cores in my machine, unlike My Computer which runs a single thread and uses only an eighth of my available processing power.
    Reinstall? Something backend? Force Refresh somewhere I'm unfamiliar with?
    I've had my fair share of Qmaster/Compressor problems in the past, but this time I'm not having any trouble finding my cluster in Qadministrator, my Qmaster System Prefs aren't greyed out or anything, the only thing I can think of is my recent update to 10.6.3, but I can't be sure that was the trigger.

    Do you have any issue with just creating a regular cluster? instead of a quick cluster? it's not hard and much more reliable. Follow the steps below (this was originally written for multiple computers so if something references multiple computers, sorry- I did my best to edit my previous post to somebody else)
    Stop All services in the Qmaster Prefs window.
    Under the "setup" tab, Click the middle Bubble "Services and cluster controller". In the "services" section next to compressor check both "share" and "managed" boxes. Options for selected services, click and set as high (or low) as you want. More = Faster, Less = slower but sometimes more stable depending on your RAM.
    In the advanced tab, delete files older than : 7 days should suffice unless space is a problem. make it smaller.
    Reset the services by holding option and clicking the "start services" and then hit ok on drop-down warning that will show up. Release option and click "Start Sharing".
    Open "Apple Qadministrator". On the upper-left field are the actual Clusters (shouldn't be anything there). click the "+" symbol and create a cluster, Name it whatever you want. On the lower field (Qmaster Service Browser, May be hidden, just click the grey triangle to the left to drop down the field) there should be a list of the computers you have available to cluster. Click on the cluster you just created, Select all the computer in the Qmaster Service browser, and drag it into the upper right field, anywhere in the rectangle. The outer edge should highlight with a thick black bar. release and the computer should move into that field and out of the Qmaster Services Browser.
    Click on the "Controller" drop-down menu and Select the controller. When you hit Apply, the "Storage:" Field (directly under the "Controller" drop-down box) should change to reflect the storage location you set in the Qmaster Preferences. When you do this, you have created a cluster.
    When you send out of compressor - make sure you are either sending Quick time reference files (you shouldn't have any issues with that) or quicktime self-contained files.
    You CANNOT "Export to compressor..." from final cut. You CANNOT have your timeline open and do the usual "file>export>using compressor...". You MUST export a QuickTime reference (faster by only using render referenced files. THE TIMELINES MUST BE FULLY RENDERED, option+R instead of Cmd+R) or QT Self-Contained File (slower but more reliable as every frame is rendered. This can triple your time).
    It's an extra step up front, but the transcoding time is SIGNIFICANTLY faster - and you can continue working in final Cut on other projects.
    Let me know if you need further assistance.

  • Ironport c160 cluster problems

    Hi!
    I have two Ironport C160 in cluster mode, tonight one of them has stopped working, and I can not access this on, but it responds to ping.
    In the system log I found only the following line:
    Mon Mar 12 15:30:39 2012 Warning: Error connecting to cluster machine xxxxx (Serial#: xxxxxx-xxxxxx) at IP xx.xxx.xxx.x - Operation timed out - Timeout connecting to remotehost cluster
    Mon Mar 12 15:31:09 2012 Info: Attempting to connect via IPxxxxx toxxxxxxxx port 22 (Explicitly configured)
    My version is:6.5.3-007
    What I can log to find the cause of the problem?
    How I can find out what the problem?
    How can you solve?
    Thank you very much

    Well, "queuereset" is not a valid command, what you mean is "resetqueue", which I would strongly not recomment  to use without having a very good reason.Because this command removes all messages from the workqueue, delivery queues, and quarantines. There are usually less destructive ways to fix a cluster problem.
    BTW, version 5.5 has long been gone, so we won't need to reference any bugs from there any more.
    Regards,
    Andreas

  • SPF is not supported SCVMM cluster problems, when repairing ?

    SPF is not supported SCVMM cluster problems, when repairing ?

    See:
    *http://forums.sdn.sap.com/thread.jspa?threadID=2056183&tstart=45#10718101

  • Master /Detail create problem

    hi,everyone:
    Firstly to say sorry for my bad English.
    Now I have a question:
    I'm working in JDeveloper 10.1.3 .The model layer is SessionEJB /Toplink ,and the view layer is JSF. I have a data structure :
    HrUnit : Master
    HrHuman : detail
    HrKnowledge : detail
    the <HrHuman>'s PRIMARYKEY is <ID>,and the <HrKnowledge>'s FOREIGN KEY is <RYID>.
    and I want to make a page to insert a new row on <HrKnowledge>. I drag the <hrKnowledgeCollectionIterator> into the page as <ADF Creation Form>, the page run fine.
    next step, I make <persistEntity> binding to the <submit button> and the parameters(entity) is
    ${bindings.hrKnowledgeCollectionIterator.currentRow.dataProvider}.
    when i run the page , i get a wrong . i get the SQL in the <Unit of work > is
    "INSERT INTO HrUnit ....."
    i create a direct mapping for the detail's foreginkey in toplink,and when i "rebuild" the map ,it gives me a warning. This warning affect my custom code in EJB,it can't work correctly. So i can't use this way in my question.
    Re: Master /Detail  create problem
    I beg your help.
    Thanks. and very very thanks.

    Hi,
    I am not an expert in TopLink, but it appears to me that the TopLink model is causes your problems not ADF. There is a TopLink forum here on OTN that could give you a helping hand on this issue.
    The following tutorial explains the use of TopLink in ADF
    http://www.oracle.com/technology/obe/obe1013jdev/10131/10131_adftoplink/master-detail-edit_page_adf_toplink.htm
    Frank

  • Master data avtivation problem

    Hi All,
    Any budy help me on this issue ,
    i have a master data activation problem ,
    after loading the master data i run the attribute change run it is sucessfully compleated ,but the proble master data tables is not updated status is still in 'M' version in 0Person table
       PERSON   OBJVERS
       00019823 A     
       00019823 A     
       00019823 M     
       00019823 M
    i want to activate this      'M' version to 'A' version\
    this is an urgent issue please help ASAP.
    Thanks,
    Tom

    Hello ALl,
    I am also facing the same problem(activation of master data) but with 0COSTCENTER. I have checked records in CSKS table in R/3 system. I could not see any M version records lying there.I have done fresh reload and ran successfully attribute change run also.
    this is very urgent,please help me ASAP.
    many Thanks in advance.
    Regards
    Ramprasad

  • BorderManager Cluster problems

    I have set up a 2 node NW 6.5 SP8 cluster to run BorderManager 3.9 SP2. I don't have a 'Split Brain Detector' (SBD) partition; the servers only monitor each other through the LAN heartbeat signal that is being sent by the master and replies by the slave. This has worked well from a high availability perspective but I keep running into a situation where both nodes will go 'active'.
    Usually, I have Node 0 set as both the cluster master and the host of the NBM proxy resource. Node 1 is then in standby - ready to load the proxy service and assume the proxy IP address if node 0 dies. At some point (the time is variable in days 2 - 5 and doesn't seem to be related to network load) Node 0 will think that Node 1 has failed and will show that on the Cmon console. Shortly afterwards Node 1 will think that Node 0 has failed and bind the proxy IP and cluster master IP and load the proxy. At this time I have two servers; both with the same Cluster Master IP bound and the proxy IP bound and proxy.nlm loaded!
    I can access Node 0 through rconj and it appears to be working fine. If I do a 'display secondary ipaddress' I can see it has both the proxy IP and Cluster Master IP bound to it. The same thing is the case for Node 1. I unload the proxy on Node 0 and reset the server. When it comes back up, it joins the cluster just fine and there doesn't appear to be any other problem.
    Has anyone else seen this behavior? (Craig???)
    thanks,
    Dan

    In article <[email protected]>, Dchuntdnc wrote:
    > but I keep running into a situation where
    > both nodes will go 'active'.
    I've got one of those situations too, at a client.
    >
    > Usually, I have Node 0 set as both the cluster master and the host of
    > the NBM proxy resource. Node 1 is then in standby - ready to load the
    > proxy service and assume the proxy IP address if node 0 dies. At some
    > point (the time is variable in days 2 - 5 and doesn't seem to be related
    > to network load) Node 0 will think that Node 1 has failed and will show
    > that on the Cmon console.
    This sounds familiar, except for me it happens within hours.
    > Shortly afterwards Node 1 will think that
    > Node 0 has failed and bind the proxy IP and cluster master IP and load
    > the proxy. At this time I have two servers; both with the same Cluster
    > Master IP bound and the proxy IP bound and proxy.nlm loaded!
    Yep. Gets annoying, to say the least!
    >
    > I can access Node 0 through rconj and it appears to be working fine.
    > If I do a 'display secondary ipaddress' I can see it has both the proxy
    > IP and Cluster Master IP bound to it. The same thing is the case for
    > Node 1. I unload the proxy on Node 0 and reset the server. When it
    > comes back up, it joins the cluster just fine and there doesn't appear
    > to be any other problem.
    Yep.
    >
    > Has anyone else seen this behavior? (Craig???)
    I have definitely fought this issue, but only on one (of many) BM cluster.
    Both nodes of the cluster are on old servers, and when the proxy is
    active, it is exceptionally busy. (More than 2000 users, and plenty of LAN
    bandwidth). I was on site at the client working on this (and a lot of
    other projects) and I never was able to get to the bottom of it. The fact
    that the server was so busy (24x7) made it hard to experiment on. My hope
    at this point is to get decent newer hardware in there to replace the
    7-year old nodes.
    This happened when one server was BM 3.8 and the other BM 3.9, but it
    continued to happen when I upgraded both to 3.9sp2. It also happened even
    though I moved the heartbeat to dedicated nics with a crossover cable.
    I'm thinking that something causes the LAN drivers to hiccup long enough
    for the server to stop responding to heartbeat - but the proxy seems to
    work continuously without showing a 30-second pause anywhere.
    For the time being, I've left the oldest node not loading cluster
    services. It's a manual failover at this time, but that's better than
    nothing. (And the primary node is quite stable anyway, for months and
    months at a time).
    Craig Johnson
    Novell Support Connection SysOp
    *** For a current patch list, tips, handy files and books on
    BorderManager, go to http://www.craigjconsulting.com ***

  • Compressor 4 cluster problem

    I have just set up my MacBook Pro and iMac with Compressor 4 as a cluster. Everything looks fine, but when I send the file out to render it fails with an error "error reading source.....no such file or directory". The file renders fine when I don't tick the "this computer plus" box.
    I've followed the path Compressor is using and it points to the alias in the events folder which goes from the "original media" folder back to the actual location of the .mov files. Sure enough, in Finder, OS X tells me the alias has failed. However, when I try to fix it and browse to the original file, the "OK" button lights up but nothing happens when I click it. This seems to be the case for ALL .mov files in every project I have edited.
    The weird thing is that FCP X can obviously see all of these files as everything works fine - I can edit and render with no problem. The issue only arises when I choose "this computer plus" or pick a cluster.
    So it looks like the aliases do point to the correct files but cannot be accessed directly from the Finder or when Compressor 4 looks for them in cluster mode.
    I hope that makes sense.
    Hopefully someone has seen similar behaviour.
    Thanks,
    Jack.

    Hi Studio X, not sure how to do that but I just worked it out. It was (as you seem to have worked out) the alias that was the clue.
    I had put together these FCP X projects on a different USB drive. As I wanted to be more organised I copied over all the projects to a new 1TB USB drive which I'm only using for storage and editing. The good thing about this is that I can simply remove the drive and plug it into a different Mac and FCP X sees everything - events, projects, original files. However, there must be some reference to the name of the old USB drive as part of the alias which Compressor doesn't like when in cluster mode. I started a quick project on the new drive and Compressor 4 worked as a 3 machine cluster with no problems.
    I can't quite understand why FCP X finds the original video at all if it is looking for the drive name and not just the path to the files, but it seems not to care.
    Anyone have any ideas about this?

  • Abrupt shutdown of master node causes problem

    A service in usmbcom1 (LMID ) makes tpacall to a service which is
    present in
    both usmbapp1 ( master node LMID ) and usmbapp2 ( slave node LMID
    ) ( HERE
    usmbcom1 , usmbapp1 and usmbapp2 are LMIDs whereas the
    corresponding physical m/cs unames are usmbd5 , usmbd3 and usmbd4
    They are separate sun boxes) . LDBAL = Y and tpacall is done at
    25 / sec.
    Now there are 2 scenarios.
    1. While tpacall is in progress we kill the servers in usmbapp1
    using
    kill command ( not kill -9) . Then clean up the ipcs. Only
    few ( 3-5 out of a
    total of 5000 ) messages were lost . This is understandable since
    messages
    which were already in the queue got lost). The rest of the messages
    were
    processes by usmbapp2.
    2. In this case we switched off the sun box usmbapp1 ( m/c name
    usmbd3)
    while tpacall was in progress. This time we lost approx 50% of
    the
    messages. However if we go to the slave m/c i.e usmbapp2 and manually
    make it master ( tmadmin ... master) ., then from that point of
    time we stopped
    losing messages.
    Does that mean manual intervention is necessary if DBBL goes
    down? Is there anything which I am missing out while configuring
    the system?

    Hi Scott,
    You did understand the scenario and the problems.
    The answers are quite convincing.
    Actually the QA team here are doing failover testing
    and they have both these ( kill and m/c shutdown)
    as their test cases.
    However I would like to know about what you meant
    by High Availability Solutions.
    Do you also mean that if I shutdown my master m/c
    then no event would be written in the ULOG of slave,
    which can be monitored and used to convert the slave
    into master programatically ( I mean thru tpadmcall)
    Thanks
    Somashish
    Scott Orshan <[email protected]> wrote:
    Hi,
    I'm not sure if I completely comprehend your situation,
    but let me take
    a guess.
    When you killed the processes (including the Bridge),
    which by the way
    is a bad thing to do to TUXEDO, TCP notified the other
    connected nodes
    that the connection had dropped. This happens fairly quickly.
    But if you just turn off a machine, TCP may not detect
    it until it times
    out, which can take several minutes. Since TUXEDO was
    doing Round Robin
    load balancing, half the requests were sent to the Bridge,
    with a
    destination of the dead machine.
    To answer your final question, the DBBL has to be migrated
    manually,
    unless you are using one of our High Availability solutions
    that uses an
    external monitor.
    The reason is that it is very hard to distinguish between
    a network
    failure or slowdown, and a real failure of the Master
    node. And it would
    be very bad to have two machines in the domain acting
    as the Master.
         Scott Orshan
         BEA Systems
    Somashish Gupta wrote:
    A service in usmbcom1 (LMID ) makes tpacall to a servicewhich is
    present in
    both usmbapp1 ( master node LMID ) and usmbapp2 ( slavenode LMID
    ) ( HERE
    usmbcom1 , usmbapp1 and usmbapp2 are LMIDs whereas the
    corresponding physical m/cs unames are usmbd5 , usmbd3and usmbd4
    They are separate sun boxes) . LDBAL = Y and tpacallis done at
    25 / sec.
    Now there are 2 scenarios.
    1. While tpacall is in progress we kill the serversin usmbapp1
    using
    kill command ( not kill -9) . Then clean up theipcs. Only
    few ( 3-5 out of a
    total of 5000 ) messages were lost . This is understandablesince
    messages
    which were already in the queue got lost). The restof the messages
    were
    processes by usmbapp2.
    2. In this case we switched off the sun box usmbapp1( m/c name
    usmbd3)
    while tpacall was in progress. This time we lost approx50% of
    the
    messages. However if we go to the slave m/c i.e usmbapp2and manually
    make it master ( tmadmin ... master) ., then from thatpoint of
    time we stopped
    losing messages.
    Does that mean manual intervention is necessary if DBBLgoes
    down? Is there anything which I am missing out whileconfiguring
    the system?

  • Master Collection Uninstall Problem

    Hello,
    I downloaded and installed the trial version of Adobe Master Collection CS6 some time ago and now I would like to unistall some of its feature that I don't use like Flash Cs6, but I ran into a big problem :
    When I look into my list of programs (on Windows 7), I don't see the Master Collection file anymore!! So I can't open the unistall program, where I should simply have to select Flash and unistall it!
    How could I run the utility manually?
    Please Help me!
    Thanks!
    Pierre Romani

    Hello Rave,
    Thank you for your quick answer!
    I don't want to uninstall the entire Master Collection, only a part of it.
    Are you sure it won't unistall it all?
    Will I still be able to run the trial version of Photoshop after using the cleaning tool?
    I mean without re-installing it after ?
    Thanks!

  • Master data access problem

    Hi All
    I  have a master data object  ..it is a z object where it has customer as the key and  the attributes are salesoffice, sales dist and sales group.
    I am using this master data object in one of my req where  in the transaction data i get only the customer and from there i am pulling the sales office,sales dist and sales group from this master data object using the option  READ MASTER DATA at the transformation level in the Rule details.
    The problem is that i am able to get the data for  all the customer's except  5 customers but when i get in to the master data and check the sales off, sales dist and region is maintained there, but still it is not picking only for those 5 customers and for rest of the customers it is working fine..
    so i thought i should be some master data problem and i deleted that master data using delete master data option with out sid's and reloaded it again and after that i reloaded the transaction data back..but still it is having the same problem but at the object level the data is there...
    Can any one suggest me as to wat would the problem can be?
    Please i appreciate your quick repaonses.
    Regards
    Shilpa

    Hi Shilpa
    May i suggest an alternate solution?
    Instead of reading values into your infoprovider using Read master data, you can enable the attributes as navigational attributes and include them in your infoprovider. You will be able to see them in reporting and also use filters or variables on the attributes too.
    You can also check if the attribute change run for the loaded master data is done before trying to run the report.
    I hope this helps.
    Thanks.

  • K7D Master-L graphics problem: multiple display adapters/no winxp star

    Hiya,
    I just recently bought a new K7D Master-L and I've had a few problems with it. Other than these issues the board has been great, but this is getting pretty annoying and I can't seem to fix it, so I'm posting here for advice/help/solutions.
    System Specs: I have two AthlonMP 1900+ and 786MB Corsair RAM (registered PC2100, 512MB in slot 1, 256MB in slot 2). I have a WD400JB (40GB ATA100 drive with 8MB buffer) and a generic IDE CD/DVD-ROM. I have an ATI Radeon 9700 Pro AGP card running at 4x.
    When I first installed the motherboard I tried to load Windoze XP on it (actually I first used Linux but had ...driver problems). Anyway XP seemed to install fine, but upon reboot, the system would get to the "progress bar"/"OS loading" screen (the small blue bar that goes back and forth) and the bar would get stuck exactly 2 "bars" from where it started--every time. I could boot into safe mode, but nothing seemed screwy. Doign the command-line boot (I think) where it shows the drivers it is loading, it got to the "agpgart" file then stopped, maybe this was the problem. I gave up after a dozen reboots or so, trying various things, and installed Windows 2000+SP3.
    Win2K installed fine, and after installing the drivers on MSI's site for northbridge, southbridge, audio, and lan, and installing ATI's latest Catalyst 3.4 drivers (I also tried 3.2), device manager had no more problems, save one.
    The problem is that there are two display adapters listed: "RADEON 9700" and "RADEON 9700 (Secondary)". There were two adapters listed before I installed the drivers, called something like "Display Adapter" and "Display Adapter (VGA compatible)". In Properties it says "PCI Slot 4 (PCI bus 1, device 5, function 0)", is this normal for AGP cards? Here is a screenshot (I disabled one to see if that helped my settings-loss problem, but it doesn't):
    [ALIGN=center][/ALIGN]
    Whats worse is that the display settings don't seem to stick around across reboots--it always reverts to the default settings of 640x480x16--which is extremely annoying. These problems exist regardless of whether I have a Service Pack installed (currently I'm running on a fresh Win2K install with no updates and having the same issues). I've tried multiple drivers for the card and no change, I've tried with/without the updated chipset drivers, and I've had this same setup work on my previous motherboard (Tyan Tiger MP) without seeing multiple display adapters.
    Any ideas? Or is there something that might fix my WinXP startup freeze? If so I could reinstall WinXP and see if that has the same multiple adapter problem...
    Thanks for any advice.
    Josh

    Well my system just booted into 640x480x16, so it appears those registry changes didn't fix the issue. The registry settings were simply changed back to 640x480x16 for some reason. I haven't reinstalled the motherboard drivers, but I gathered them all up and I'll try this later today. Here are the latest drivers I found, all from MSI's site:
    Onboard AC97 Codec Driver
    Support model:   K7D Master (MS-6501)
    Description:   AMD AC97 Codec Driver version 10B
    Date:      2002-8-20
    http://download.msi.com.tw/support/dvr_exe/AC97_Codec.exe>
    Intel 10/100 LAN device driver for Win2000
    Support model:   MS-6508...MS-6501...MS-9202
    Description:   A formal release from Intel.
          For integrated Intel 10/100 Lan.
    Date:      2003-2-25
    http://download.msi.com.tw/support/dvr_exe/intel_Win2000_for_100.exe>
    AMD 762 Driver
    Support model:   K7D Master (MS-6501)
    Description:   - WHQL Certified Driver
          - Added support for Windows XP
          - Changed settings to only use auto-compensation for the AMD-762 (MP) Northbridge(2000/XP).
    Date:      2002-8-20
    http://download.msi.com.tw/support/dvr_exe/MINIPORT_533.EXE>
    AMD 768 Driver
    Support model:    K7D Master (MS-6501)
    Description:   - WHQL Certified Driver
    Date:       2002-8-20
    http://download.msi.com.tw/support/dvr_exe/POWMGMT_122S.EXE>
    AMD EIDE Driver
    Support model:    K7D Master (MS-6501)
    Description:   - WHQL-Certified for Windows 2000/XP ONLY. Version 1.43s
    Date:      2002-8-20
    http://download.msi.com.tw/support/dvr_exe/EIDE_143S.EXE>
    Microsoft Windows® 2000 Patch for AGP Applications on AMD platforms
    Support model:   K7D Master (MS-6501)
    Description:   This is a registry file for Windows 2000
    Date:      2002-8-20
    http://download.msi.com.tw/support/dvr_exe/largePageMinimum.reg>
    Award® BIOS I have 1.6 (?)
    File Size:   234KB
    Version:   1.82
    Update date:   2003-5-12
    Update Description:   Support AMD MP 2800+ in correspondance with AMD web site recommendation
    http://download.msi.com.tw/support/bos_exe/6501v182.exe>
    *** NOT USED: OLD DATE AND WRONG CHIPSET NUMBER ***
    Onboard NIC Driver
    Support model    K7D Master (MS-6501)
    Description    
    -Intel GD82559ER LAN chipset driver
    Date    2002-8-20
    http://download.msi.com.tw/support/dvr_exe/E100CE.exe>
    We shall see if this fixes the multiple adapter problem. As far as the display settings problem, I don't know that the deal is. It works fine on other motherboards with the same hardware and drivers, so it must be something with the K7D, Windows, and ATI interaction.
    Josh
    P.S.: There is a bug with this forum software and apostrohpies. Every time you preview your post it inserts escape characters ("\") before apostrphies, and also inserts escape characters for these escape characters, so quickly you have something like  "\\\\\\\'" where you want "'".

  • CS4 MASTER COLLECTION installation problem on VISTA SP1

    whenever i try to install CS$ MASTER COLLECTION on VISTA it shows me the following message. . .
    http://img132.imageshack.us/my.php?image=83377733oh8.jpg
    any solutions? plz help me...........

    I get the same problem - any solution yet?
    CS4 programs crash at Startup so I unistalled it plus CS4Clease and MS Clean Installer as advised in forums.
    only to find the problem is still not fixed
    when installing a
    Warning message at install stating cs4 minimum system requirements are not met (this did not appear the first time I installed the program)
    http://img132.imageshack.us/my.php?image=83377733oh8.jpg
    where as CS4 worked for several months, before the error occured
    this is the only warning
    it then installs CS4 no problem.
    after install
    Photoshop and Dreamweaver run but the rest of the packages including inDesign do not - they all crash on startup - continously
    I have searched the forums endlessly with no avail.
    Would a vista update have stopped CS4 from recognising or identifing the OS, thus causing the program to initially crash?
    Vista Home Premium SP1, 32bit, Toshiba Qosmio F50, Intel Core 2 Duo P8400 2.26GHZ
    please advise

  • CS3 Master collection installation problem on Windows 7 64 bit

    Hi Guys
    Please can you advise
    I am encountering problems with the installation of CS3 Master Collection on Windows 7 64 bit, initially my hard drive crashed and performed a dump.
    Subsequent attempts to install CS 3 has resulted in failure to install 12 components, essentially the individual software products including photoshop, encore, illustrator etc.
    I have re-performed the installation several times with the same installation error.
    I believe CS3 to be compatible with Windows 7 64 bit
    Any thoughts, guidance on how to rectify the problem and achieve successful installation.
    I do have Adobe Reader X and Flash player X already installed. I assume these should not cause an issue with the CS3 installation
    Thxs in anticipation

    Na, you have it all backwards. CS3 is neithe officially tested nor endorsed, certified or supported on W7. Many users still use it succsfully, but there ae no guarantees whatsoever. Furthermore using Acrobat X ma exactly be the problem due to certain PDF components being shared acoss apps and newer versions not being compatible with the old installer. Therefore removing those parts and reinstlling them later is advisable. Beyond hee's a procedure that should work:
    - use the Creative Suite Cleaner Tool
    - install CS3
    - uninstall CS3 via the Add or Remove Programs system control panel
    - install CS3 again
    This convoluted procedure is necessary due to bugs in the installer which otherwise prevent things from working.
    Mylenium

Maybe you are looking for

  • TS1368 Please hepl to resolve the following error message

    I have an error message "This Iphone cannot be connected because the apple mobile device service is not started" How do I start it????

  • Max Instance of One DESKI Report for Schedule

    Hi, Can someone pls let me know how many Max Instance we can create for One DESKI Report for Scheduling. Thanks in advance. Prabhat

  • Connection Pool using weblogic.jdbc.pool.Driver

    I am trying to use connection pooling in my JSP data access classes (which work fine without connection pooling) on weblogic 4.5.1. I tried using the weblogic.jdbc.pool.Driver but it exits with the following exception: java.lang.ClassNotFoundExceptio

  • Bluetooth Keyboard GONE CRAZY!

    Backspace has become forward delete up arrow/down arrow have become page up/page down Left **** and "t" will not reproduce a cap T - right shift and "t" will Checked international settings. US English is checked - but is GRAYED OU and (OUT) and can't

  • Photostream not updating on Macbook

    Hey, having issues. I have set up iPhoto etc on icloud and my iphone, however the pics do not seem to upload automatically when i switch my wifi on,I have closed the camera app and phone is on wifi with over 20%. Please helppppp!!!