Regaring change in vbeln field length to 15
Hi all ,
I need suggestion on changing VBLEN size to 15
In the Ztable i have changed filed length of vbeln to 15 and iam maintaining same conversion routine ALPHA.
Now problem is when iam selecting entry from Ztable with existing Vebln its not picking up the entry i tried with appending 0's also
If i remove conversion exit i has to give vbeln exactly same as it present in database .
Hi ,
//In the Ztable i have changed filed length of vbeln to 15 => its a zdata element.
//Now problem is when iam selecting entry from Ztable with existing Vebln its not picking up the entry -> hope ur new zdataelement is also having 10 digit valid length vbeln number stored in the ztable this is important.
did u try converting the 15 digit length to 10 digit when writeing the select .. you can user covnversionexitalphainput / covnversionexitalphaouput to achieve the same.
I dont know the data types of ur new zdataelement hope they are same..
BR,
Vijay.
Edited by: sniper on Sep 8, 2010 3:58 PM
Similar Messages
-
Task Name - Field length Change
Can we change the task name length for team members when adding a new task?
Regards, Syed Faizan ur Rehman, CBPM®,PRINCE2®, MCTSHi Syed,
If you want to change the task field length, it is not possible. It is a native field which is predefined in the system.
But if you want to change the length of the task name itself (for example "design" by "system design"), then it it possible since what matters is the task UID and not the task name.
Hope this helps,
Guillaume Rouyre, MBA, MCP, MCTS | -
Hi,
My client wants to change the account field length in the doc entry. Standard account field is length is 16 or 17 digits. Its length has to be reduced to 10 digits.
How can i do this ? Can I do this in the configuration (or) customisation ? If it is customisation what are the tables I need to touch ?
Awaiting for the reply
Thanks,
KrishnaUse Transaction code OB13 to maintain maiximum length of GL account length as 10 apart from this you can also write validation so that if any gl account with more that 10 digits is entered system gives error.
Regads,
Manish Jain
Assign points if it serves your purpose. -
Changing field length of a standard field in standard table VBEP
Hi,
Please advice the possibility and the possible repercussions of changing field lengths in a standard table. Table in concern is VBEP.
Thanks & Rgds,
PradeepNo you cannot change the field length
thanks
G. Lakshmipathi -
Idoc segment field length changes
Hi friends,,
I am new to idoc.
My requirement is in my segment
i am having 5 fields and also this segment is already realeased one.
i wnat to change the field length from 10 to 20 . how to do this ?
actually what i did is
1. i cancel the release for that segment.
2. in that field inside the dataelement i changed the field length from 10 to 20.
3. data elemnt get chaged from 10 to 20 but Export length for that field in Idoc segment still retain the 10 only
can you plz how to resolve this
devaHi,
The way you used is right. ( cancel release or create a new segment )
After you cancel release, try delete that field, and insert a new one.
If it isn't valid still, create a new segment instead.
Regards
Sam -
How to change the field length in standard sap program.
Hi All,
How to change the field length in standard sap program.
Urgent
Example:
Text1 type c length 75,
To change :
Text1 type c length 150,
Point will be rewarded..
Thank you,
Vikram.CIf the only solution is to change the sap standard program, simply change the program, it will prompt for an access key. This key can be retrieved in the SAP support portal (service.sap.com) at keys and requests, sccr keys, register object.
Sometimes these actions are outsourced to a competence center, so maybe youre not entitled to do this, in any case ask a resident senior developer for support.
regards, Rob -
Custom IDOC type Segment-field length change
Hello,
We have a custom segment developed for triggering Outbouds. I'm tring to change the Field length of a deta element used for one of the fields in the segment.
But after chaning the data element and activating it also, the changes are not effecting in WE31/ in the structure of the segment.
Process I'm following:
we31 <segment>
......cancel release
Change data element and activate
....set release.
Please suggest if something else can be done
Thanks,
Lucky.> @Sarvesh: The IDOC segment has been released. I also re-imported the IDOC into XI - is that what you mean by 'reloaded'?
No, re-importing in XI is different from reloading the metadata into ABAP stack of XI using IDX2 transaction. So if you have not done this, then this could be the main reason of truncating the length.
Regards,
Sarvesh -
Field length was changed in R/3 was this effect in BW
Hi ,
Field length of one Field was incresed in the data source.
the same data source/table is used for extracting the data from R/3 to BW.
will it effect these changes in BW side.
Thanks
RamHi Ram,
It Affects 100%.for the Data.
If the field in the data source is suppose 15 and if the Info Object In BW is 12 the there are chances of missing 3 characters which might be crucial for the client.
<i>But there will not be any effect on Transfer Rules mapping or data load</i>.
Regards,
RK. -
Risks of changing the field length of data structure of a Cluster Table
Hello,
We are on ECC 604 and had implemented HR & Travel Management. Reporting on these applications is done in BI. We use ESS and & Mobile Travel for time, travel expenses, etc and use PCLn clusters.
There is business need to change the length of a field from 20 to 40 for the data structure PTK** of cluster table PCL1.
We are exploring various options to avoid core modifications.
We are also assessing the risks associated with changing the field length.
I am asking you for your opinion about the risks associated with changing the field length of a data structure of cluster table.
Thanks & Regards,
Manoj K PingaliRecently, we came across the same situation where we had to change the length of a field. Let me explain you what precautions we had taken during that time.
1. Apply the where use list of that table/ Field and check whether it has been used in some program and FM or not. If yes then check one more thing that check the TYPE of another variables on which system has populating data (move, write or in FM parameters). if you will not consider this then you can land you in big trouble. (Conversion dump)
2. Ask the basis to take a dump of the production, quality and data for the safer side if something does not go right.
Now, you can do the changes in your development system and then adjust the database and see the impact of it.
Hopefully, you will not come across any difficult situation in this changes.
Thanks.
Anurag -
Field length change in Web Dynpro Components iView
Hi,
We are using SAP MDM Web Dynpro Components - Configuration Manager (NW7.3) to develop the UI. One of the issue while disply field is, Though field maintained in MDM has only 2 charaters UI that displays a full-screen-width field.
I would like to display actual field length maintained in reposiroy for each field. Is it possible??
Cheers,
RcThis is closed.
By mistake Raised Twice....I guess I need break -
Change field length via Admin Personalization?
As part of our ESS/MSS config, I have a requirement where I have to change the allowable number of characters for a number of input fields. Using Administrative Personalization, I can change the display field width, but I can't change the number of allowable characters.
Is this possible with configuration, or do I have to open up the code and change that (most likely dictionary changes)?
We're trying to shorten the field, so making this change should not cause any issues...but I need to know how to do it.Hi,
I believe this is not possible using the webdynpro personalization, I suggest you to modify the ESS application as you have also mentioned.
Regards,
Ervin -
How to set field length in Dynamic IT tab
Hi All,
I am creating 1 dynamic internal table with refrence of field catalog, but in the dynamic IT tab and work area i am gettinf field length is 10 char.
But i want to change this into 15 or 20 char like this.... how can i change this
Please help me .
DATA: ep_tab TYPE REF TO data,
new_line TYPE REF TO data.
FIELD-SYMBOLS: <l_table> TYPE table,
<l_line> TYPE ANY.
CALL METHOD cl_alv_table_create=>create_dynamic_table
EXPORTING
I_STYLE_TABLE = c_char
it_fieldcatalog = it_fieldcatalog
I_LENGTH_IN_BYTE = ' '
IMPORTING
ep_table = ep_tab.
ASSIGN ep_tab->* TO <l_table>.
CREATE DATA new_line LIKE LINE OF <l_table>.
ASSIGN new_line->* TO <l_line>.
This is my code.
Regards,
Arjun.Hi,
try this
** ALV DECALRATION
DATA : wa_lvc_cat TYPE lvc_s_fcat,
gt_lvc_cat TYPE lvc_t_fcat.
DATA : wa_fieldcat TYPE slis_fieldcat_alv,
gt_fieldcat TYPE slis_t_fieldcat_alv.
DATA : wa_slis_layout TYPE slis_layout_alv.
PERFORM create_dynamic_itab. " Fill fieldcatlog and create dynamic itab
*& Form CREATE_DYNAMIC_ITAB
* text
* --> p1 text
* <-- p2 text
FORM create_dynamic_itab .
CLEAR g_pos .
PERFORM fill_gt_lvc_cat_fld USING 'MATNR' 18 . "fieldname outputlen.
PERFORM fill_gt_fieldcat_field USING c_x 'MATNR' 'CHAR' 18 text-006.
PERFORM fill_gt_lvc_cat_fld USING 'CODE' 40 .
PERFORM fill_gt_fieldcat_field USING ' ' 'CODE' 'CHAR' 40 text-024.
CALL METHOD cl_alv_table_create=>create_dynamic_table
EXPORTING
it_fieldcatalog = gt_lvc_cat
IMPORTING
ep_table = new_table.
ENDFORM. " CREATE_DYNAMIC_ITAB
*& Form FILL_gt_lvc_cat_FLD
* text
* -->P_0006 text
* -->P_18 text
FORM fill_gt_lvc_cat_fld USING p_fieldname TYPE any
p_outputlen TYPE any.
wa_lvc_cat-fieldname = p_fieldname . " 'MATNR'
wa_lvc_cat-outputlen = p_outputlen. " 18
APPEND wa_lvc_cat TO gt_lvc_cat.
CLEAR wa_lvc_cat.
ENDFORM. " FILL_gt_lvc_cat_FLD
*& Form FILL_GT_FIELDCAT_FIELD
* text
* -->P_C_X text
* -->P_0012 text
* -->P_0013 text
* -->P_18 text
* -->P_TEXT_006 text
FORM fill_gt_fieldcat_field USING p_key TYPE any
p_fieldname TYPE any
p_datatype TYPE any
p_outputlen TYPE any
p_seletext_m TYPE any.
g_pos = g_pos + 1.
wa_fieldcat-col_pos = g_pos. " 1.
wa_fieldcat-key = p_key . " c_x.
wa_fieldcat-fieldname = p_fieldname. " 'MATNR'.
wa_fieldcat-datatype = p_datatype. " 'CHAR'.
wa_fieldcat-outputlen = p_outputlen. " 18.
wa_fieldcat-seltext_m = p_seletext_m. " text-006. "'Material'.
APPEND wa_fieldcat TO gt_fieldcat.
CLEAR wa_fieldcat.
ENDFORM. " FILL_GT_FIELDCAT_FIELD
PERFORM fill_output_layout. " Fill the output data into field symbol
*& Form FILL_OUTPUT_LAYOUT
* text
* --> p1 text
* <-- p2 text
FORM fill_output_layout .
ASSIGN new_table->* TO <fs_table>.
CREATE DATA new_line LIKE LINE OF <fs_table>.
ASSIGN new_line->* TO <fs_line>.
LOOP AT gt_mseg INTO wa_mseg.
ASSIGN COMPONENT 'MATNR' OF STRUCTURE <fs_line> TO <fs_field>.
<fs_field> = wa_mseg-matnr.
READ TABLE gt_grdtrans INTO wa_grdtrans WITH KEY mawerk = wa_mseg-WERKS
matnr = wa_mseg-matnr
mat_doc = wa_mseg-mblnr binary search.
IF sy-subrc = 0.
LOOP AT gt_qmfe INTO wa_qmfe WHERE qmnum = wa_grdtrans-qmnum.
READ TABLE gt_qpct2 INTO wa_qpct2 WITH KEY codegruppe = wa_qmfe-fegrp
code = wa_qmfe-fecod
BINARY SEARCH .
IF sy-subrc = 0.
ASSIGN COMPONENT 'CODE' OF STRUCTURE <fs_line> TO <fs_field>.
<fs_field> = wa_qpct2-kurztext.
ENDIF.
endloop.
clear wa_qmfe.
ENDIF.
ENDLOOP.
CLEAR wa_mseg.
PERFORM fill_layout. " Filling the layout of REUSE_ALV_GRID_DISPALY
*& Form FILL_LAYOUT
* text
* --> p1 text
* <-- p2 text
FORM fill_layout .
wa_slis_layout-zebra = c_x.
wa_slis_layout-colwidth_optimize = c_x.
ENDFORM. " FILL_LAYOUT
Edited by: ShaliniSinha on Mar 30, 2009 1:49 PM
Edited by: ShaliniSinha on Mar 30, 2009 1:55 PM -
Sql*loader field length issue
so I'm loading a file and it's rejected a record where "field in data file exceeds maximum length" the record it's failing on has data length of 625 characters. I'm loading it into a table with a field type of varchar2(1024).
for the life of me, I can't figure out why it's failing. I've even gone and manually copy and pasted the rogue record into the table (via Toad) and it works fine, but I need it to load via SQL*loader.
there is no white space that i'm not counting. Can anyone suggest where to look next?Hi,
Just change the problematic field in the control file as
load
field char(1000),
If you give the length in the control file, ur problem ll be solved.
- karthik -
ALV (Factory class) field length problem
Hi experts!
I build an ALV report using the Factory method. But I can't set the field length.
When I set the field length in a column attributes it doesn't change nothing
What is the problem?
My column attributes are like that:
TRY.
lr_column ?= lr_columns->get_column( 'NAME1' ).
lv_text_s = text-103.
lv_text_m = text-103.
lv_text_l = text-103.
lr_column->set_long_text( text-103 ).
lr_column->set_short_text( lv_text_s ).
lr_column->set_medium_text( lv_text_m ).
<b> lr_column->set_output_length( 30 ) .</b>
lr_column->set_active_for_rep_interface( gc_default ).
CATCH cx_salv_not_found.
ENDTRY.
Thanks forehead,
DaniHi,
In ur fieldcat populate the output length field.
CLEAR x_fieldcat.
x_fieldcat-fieldname = 'FLAG'.
x_fieldcat-seltext_l = 'Text' .
<b> x_fieldcat-outputlen = 30.</b>
x_fieldcat-col_pos = 1.
APPEND x_fieldcat TO it_fieldcat. -
Field length in af:query
I am using jdev11g R2 and ADF BC,
I drag and drop my VO view criteria as af:query, in side view criteria, all four criteria fields are used LOV to enter value, some field LOV will be dependent on previous fields value selected, My question is due to the dependent LOV used, so the fileds length will be dynamicly changed. Can I fixed all the fields length ? Thanks!
Edited by: xsyang on Oct 3, 2011 9:08 PM<af:query id="qryId2" headerText="Search" disclosed="true"
value="#{bindings.ScheduleOlVOCriteriaQuery.queryDescriptor}"
model="#{bindings.ScheduleOlVOCriteriaQuery.queryModel}"
queryListener="#{bindings.ScheduleOlVOCriteriaQuery.processQuery}"
queryOperationListener="#{bindings.ScheduleOlVOCriteriaQuery.processQueryOperation}"
resultComponentId="::pc2:resId2" saveQueryMode="hidden"
inlineStyle="width:900px;"
maxColumns="2" rows="1" modeChangeVisible="false"/>
Maybe you are looking for
-
HELP: How do you tell iPhoto 08 not to import dupes?
Hi, I was just looking at iPhoto 08 preferences and I can not see where I choose not to import duplicates... where or can you toggle this? I imported from an external hard drive and I just dragged the top level folder into iPhoto to begin the import.
-
Guitar audio drop-out at lower volumes
I have tried out mainstage on a friends macbook pro, to check if it will be worth an investment into Logic over Garageband, mainly as an effects emulator for my guitar so I don't need to worry about amps in my small flat. I connected through an Edi
-
The scenario is file to RFC. The RFC is called via a BPM, which receives back the respond from the RFC as well. I am finding a red flag at the receiver end in the MONI. When I click on the PE in the MONI I find ,in the workflow diagram that the file
-
Repeating records for element values
Hi, Need to get element input values,i have used pay_element_entry_values table to get he screen inpout value.Used the effective date to filter,still 2 records are fetched. E.g query SELECT DISTINCT papf.national_identifier, papf.employee_number, pap
-
Complation Requirement by Maintenance Plan
Hi PM Experts, Can i set Completion Requirement as a defaut by maintenance plan? Regards, Aktolga