SCCM 2012 R2 OSD Win7, a Reference Image or Install.wim from the Win 7 media

I want to use thin image to deploy win7.
So do I need to built a reference Image, or I can use install.wim from Windows 7 media directly?
I saw someone suggest built a reference Image fist. so what different between  builting a reference Image or using install.wim from Win7 media?

Hi,
When you build your won reference image you can include your own software and Software Updates which makes it a lot faster to deploy. I normally add:
- Windows 7 hotfixes that are not delivered through WSUS/Microsoft Update
- Visual Studio Runtimes 2005,2008,2010,2012
- .NET framework 4.5
- And all the latest software updates from Microsoft.
So I recommend that you create your own image.
Regards,
Jörgen
-- My System Center blog ccmexec.com -- Twitter
@ccmexec
Also it's best practice to build and capture using a VM rather than physical.
Cheers
Paul | sccmentor.wordpress.com

Similar Messages

  • Fasten the Process of MDT UDI OD Installation in SCCM 2012 R2 OSD

    Hi,
    I have implemented MDT UDI Task Sequence in SCCM 2012 R2 OSD. The issue  which I am facing is the UDI Installation progress is very slow. it is taking around 2 hours to complete the whole Installation. 
    Is there any way to fasten the Process of MDT UDI OD Installation in SCCM 2012 R2 OSD.
    Thanks & Regards,
    Sanjay Dubey

    Application installs can take awhile - it depends on what applications you're installing, and how many.  For instance, installing Office is clearly going to take longer than say 7-Zip.  How many applications are you installing during a normal OS
    deployment?  You can check the AppEnforce.log to see how long an application(s) is taking to install, as the start and end times are recorded.  
    As for the MDT Settings package, how many times are you calling this package?  My task sequence only calls it 5 times, and one of them is before you even get the UDI wizard, while the second and third is an either/or situation, depending on whether
    you do a refresh or a fresh PC build. 

  • SCCM 2012 SP1 - OSD Task Sequence - Auto Apply Drivers

    I have a basic task sequence created, capture User State, reboot into Windows PE, Apply Operating system, apply Windows Settings, Auto Apply Drivers, Setup Windows and Configuration, Install Applications, Restore User state
    The problem I'm having is auto Apply the drivers. My test system is a Dell Opitiplex 3010, with a realtek PCI GBE Family Controller being the only driver added to the driver database.
    During the task sequence, I see it down loading the driver, then proceed though the whole sequence. The system restarts and brings up the login. Here is the problem, the network drivers don't install, so the system is still in a workgroup, with no user state
    restore.
    I repeat the task, this time during the Setup Windows and Configuration, I press F8, and copy the _SMSTaskSequence folder to C:\temp.
    Once the task in complete, I see the network drivers saved in _SMSTaskSequence\Drivers & \contentCache. I able to install the network drivers from this location.
    What am I missing, why are the network drivers not being setup correctly in Windows 7?
    From the \logs\SMST.LOG, I can see the driver being installed correctly, but one the sequence is complete the driver has not been installed.
    From the SMSTS.LOG:
    Installing driver "Realtek PCI GBE Family Controller" OSDDriverClient 3/21/2014 5:52:37 PM 900 (0x0384)
    Copying "C:\_SMSTaskSequence\ContentCache\BA4B1243-742B-4BFA-8245-89E7B33DE1C5" to "C:\_SMSTaskSequence\drivers\1". OSDDriverClient 3/21/2014 5:52:37 PM 900 (0x0384)
    Successfully installed driver "Realtek PCI GBE Family Controller". OSDDriverClient 3/21/2014 5:52:37 PM 900 (0x0384)
    Entering ReleaseSource() for C:\_SMSTaskSequence\ContentCache\BA4B1243-742B-4BFA-8245-89E7B33DE1C5 OSDDriverClient 3/21/2014 5:52:37 PM 900 (0x0384)
    reference count 1 for the source C:\_SMSTaskSequence\ContentCache\BA4B1243-742B-4BFA-8245-89E7B33DE1C5 before releasing OSDDriverClient 3/21/2014 5:52:37 PM 900 (0x0384)
    Released the resolved source C:\_SMSTaskSequence\ContentCache\BA4B1243-742B-4BFA-8245-89E7B33DE1C5 OSDDriverClient 3/21/2014 5:52:37 PM 900 (0x0384)
    Failed to find a suitable device driver for device 'Microsoft ACPI-Compliant System'. OSDDriverClient 3/21/2014 5:52:37 PM 900 (0x0384)
    Failed to find a suitable device driver for device 'Microsoft Basic Render Driver'. OSDDriverClient 3/21/2014 5:52:37 PM 900 (0x0384)
    Failed to find a suitable device driver for device 'Intel(R) 6 Series/C200 Series Chipset Family USB Enhanced Host Controller - 1C26'. OSDDriverClient 3/21/2014 5:52:37 PM 900 (0x0384)
    Failed to find a suitable device driver for device 'Intel(R) 82802 Firmware Hub Device'. OSDDriverClient 3/21/2014 5:52:37 PM 900 (0x0384)
    Failed to find a suitable device driver for device 'Generic volume'. OSDDriverClient 3/21/2014 5:52:37 PM 900 (0x0384)
    Failed to find a suitable device driver for device 'ACPI Fixed Feature Button'. OSDDriverClient 3/21/2014 5:52:37 PM 900 (0x0384)
    Failed to find a suitable device driver for device 'HID-compliant mouse'. OSDDriverClient 3/21/2014 5:52:37 PM 900 (0x0384)
    Failed to find a suitable device driver for device 'Motherboard resources'. OSDDriverClient 3/21/2014 5:52:37 PM 900 (0x0384)
    Failed to find a suitable device driver for device 'CD-ROM Drive'. OSDDriverClient 3/21/2014 5:52:37 PM 900 (0x0384)
    Failed to find a suitable device driver for device 'USB Root Hub'. OSDDriverClient 3/21/2014 5:52:37 PM 900 (0x0384)
    Failed to find a suitable device driver for device 'System timer'. OSDDriverClient 3/21/2014 5:52:37 PM 900 (0x0384)
    Failed to find a suitable device driver for device 'Generic USB Hub'. OSDDriverClient 3/21/2014 5:52:37 PM 900 (0x0384)
    Failed to find a suitable device driver for device 'USB Input Device'. OSDDriverClient 3/21/2014 5:52:37 PM 900 (0x0384)
    Failed to find a suitable device driver for device 'ACPI Power Button'. OSDDriverClient 3/21/2014 5:52:37 PM 900 (0x0384)
    Failed to find a suitable device driver for device 'High Definition Audio Controller'. OSDDriverClient 3/21/2014 5:52:37 PM 900 (0x0384)
    Failed to find a suitable device driver for device 'Motherboard resources'. OSDDriverClient 3/21/2014 5:52:37 PM 900 (0x0384)
    Failed to find a suitable device driver for device 'Microsoft System Management BIOS Driver'. OSDDriverClient 3/21/2014 5:52:37 PM 900 (0x0384)
    Failed to find a suitable device driver for device 'Intel Processor'. OSDDriverClient 3/21/2014 5:52:37 PM 900 (0x0384)
    Failed to find a suitable device driver for device 'Intel Processor'. OSDDriverClient 3/21/2014 5:52:37 PM 900 (0x0384)
    Failed to find a suitable device driver for device 'Intel Processor'. OSDDriverClient 3/21/2014 5:52:37 PM 900 (0x0384)
    Failed to find a suitable device driver for device 'Intel Processor'. OSDDriverClient 3/21/2014 5:52:37 PM 900 (0x0384)
    Failed to find a suitable device driver for device 'PCI Simple Communications Controller'. OSDDriverClient 3/21/2014 5:52:37 PM 900 (0x0384)
    Failed to find a suitable device driver for device 'HID Keyboard Device'. OSDDriverClient 3/21/2014 5:52:37 PM 900 (0x0384)
    Failed to find a suitable device driver for device 'Generic volume'. OSDDriverClient 3/21/2014 5:52:37 PM 900 (0x0384)
    Failed to find a suitable device driver for device 'Generic Monitor'. OSDDriverClient 3/21/2014 5:52:37 PM 900 (0x0384)
    Failed to find a suitable device driver for device 'USB Input Device'. OSDDriverClient 3/21/2014 5:52:37 PM 900 (0x0384)
    Exiting with return code 0x00000000 OSDDriverClient 3/21/2014 5:52:37 PM 900 (0x0384)
    Process completed with exit code 0 TSManager 3/21/2014 5:52:37 PM 1300 (0x0514)
    !--------------------------------------------------------------------------------------------! TSManager 3/21/2014 5:52:37 PM 1300 (0x0514)
    Successfully completed the action (Auto Apply Drivers) with the exit win32 code 0 TSManager 3/21/2014 5:52:37 PM 1300 (0x0514)

    Yes, I open a dos box during the Windows Setup, xcopy SMSTaskSequence to C:\temp
    Then once Windows install is completed, I login to the local Admin account(only thing available), device manager and install the network driver from C:\temp\SMSTaskSequence\drivers\1
    From Earlier in Setupact.log:
       PnPIBS: C:\_SMSTaskSequence\drivers is listed as a driver path in unattend.xml ...
    2014-03-25 12:27:22, Info                         PnPIBS: Found the file rt64win7.inf
    2014-03-25 12:27:22, Info                         PnPIBS: Added driver C:\_SMSTaskSequence\drivers\1\rt64win7.inf to the list of drivers.

  • How to add multiple images to a JLabel from the jar file

    I want to add multiple images in a JLabel but the icon property only allows me to add one. I thought I could use html rendering to add the images I need by using the <img> tab, but I need to use a URL that points to the image.
    How do I point to an image inside the jar file? If I can't, is there another way to show multiple images in a JLabel from the jar file?

    Thanks, it works perfectly. It's a really smart way of fixing the problem too :)
    I also found your toggle button icon classes which is something I've also had a problem with.
    Thanks.

  • Latitude E6330 BSOD via SCCM 2012 R2 OSD

    Hi All,
    I'm currently struggling to build some Latitude E6330 laptops via SCCM 2012 R2 CU3 OSD . I'm getting a BSOD with error code 0000007E after the drivers are applied and the laptop reboots.
    I've built nearly 100 OptiPlex desktops without issue from the same server. I've tried both the A09 and A10 E6330 driver CABs, and both have the same issue. I was having an issue even building the boot image with these drivers, but removed a faulty driver
    before importing them into SCCM (Conexant USB Modem driver) which resolved that issue. I'm assuming that the removal of this driver wouldn't be causing the BSOD - but I'm currently trying to find a replacement driver to see if that resolves it anyway.
    I've tried using 'Auto Apply Drivers' and 'Apply Driver Package' in the task sequence, using a WMI query and also without a WMI query to no avail. I've blown away all previous drivers, imported only the A09 and then blew away + imported only the A10
    drivers, rebuilt the driver packages and re-added to the boot image numerous times. Yep I've been distributing/updating distribution points each time too :)
    Unfortunately I can't get onto the laptop to check the smsts/setupact/etc etc logs because it blue screens even in safe mode.
    My last resort will be to add just the network+HDD drivers, and then slowly add drivers until I figure out what driver is causing the BSOD. Unfortunately this would be quite a lengthy procedure, so I'm hoping that someone has had a similar problem and
    may know which driver could be causing me this grief.. Or perhaps could point me in a different direction as to what may be causing this issue....
    Thanks for your time.

    Are you trying to deploying Windows 7 to the laptops?
    If so does your WIM file include the platform update (how long has it been since you created / updated it)? If not then you may need to update / capture a new wim and try again. 
    A lot of newer drivers will cause this sort of problem if you try and inject them into an older wim file.
    If this isn't the case, then I have had this happen to me a long time ago with a webcam driver so maybe exclude these drivers first? A long shot though.
    Cheers
    Damon

  • SCCm 2012 R2 - OSD fails when multiple computers are getting built

    Hi everyone,
    I ran into a weird issue with my SCCM 2012 R2. I noticed when I build one computer with SCCM OSD, it works fine. But when I try to run more than one built at a time, only one usually works. The rest usually doesn't get apps installed in the task sequence,
    some don't get added to the domain etc. Any idea what it might be? Could it be that simultaneous connections to the distribution point are getting terminated and imaging fails?
    Appreciate your help! 

    Ok guys, this seems to be a false alarm here. It turns out I was missing a driver for ethernet card on my Dell T1600. I kicked off 3 Dell Optiplex 9020 and they all worked flawlessly. This is weird though, since I did install OS on some T1600 before and
    they all worked fine...
    Anyway, I downloaded the driver and added it to SCCM. I will kick off the install again today and see if that solved it.

  • SCCM 2012 CU2 OSD forest trust: ReleaseRequest failed with error code 0x87d00317

    Hello,
    Actually i have a difficult Problem with my SCCM 2012 R2 CU2 Windows 7 x64 SP1 Tasksequence:
    I get the folowing error in smsts.log:
    ::RegQueryValueExW(hSubKey, szReg, NULL, NULL, NULL, &dwSize), HRESULT=80070002 (e:\qfe\nts\sms\framework\tscore\utils.cpp,811) TSManager 9/5/2014 1:20:35 PM 1740 (0x06CC)
    RegQueryValueExW is unsuccessful for Software\Microsoft\SMS\Task Sequence, SMSTSEndProgram TSManager 9/5/2014 1:20:35 PM 1740 (0x06CC)
    GetTsRegValue() is unsuccessful. 0x80070002. TSManager 9/5/2014 1:20:35 PM 1740 (0x06CC)
    End program:  TSManager 9/5/2014 1:20:35 PM 1740 (0x06CC)
    Finalize logging request ignored from process 1736 TSManager 9/5/2014 1:20:35 PM 1740 (0x06CC)
    Waiting for CcmExec service to be fully operational TSManager 9/5/2014 1:20:35 PM 1740 (0x06CC)
    CcmExec service is up and fully operational TSManager 9/5/2014 1:20:35 PM 1740 (0x06CC)
    Access handle will be read from _SMSTSActiveRequestHandle TSManager 9/5/2014 1:20:35 PM 1740 (0x06CC)
    Access handle: {B699D570-B2BF-4874-8CB7-3B208B380969} TSManager 9/5/2014 1:20:35 PM 1740 (0x06CC)
    Attempting to release request using {B699D570-B2BF-4874-8CB7-3B208B380969} TSManager 9/5/2014 1:20:35 PM 1740 (0x06CC)
    CoCreateInstance succeeded TSManager 9/5/2014 1:20:35 PM 1740 (0x06CC)
    pISoftwareExecutionRequestMgr->ReleaseRequest(ActiveRequestGUID), HRESULT=87d00317 (e:\nts_sccm_release\sms\client\tasksequence\tsmanager\tsmanagerutils.cpp,136) TSManager 9/5/2014 1:20:35 PM 1740 (0x06CC)
    ReleaseRequest failed with error code 0x87d00317 TSManager 9/5/2014 1:20:35 PM 1740 (0x06CC)
    Task Sequence Manager could not release active TS request. code 87D00317 TSManager 9/5/2014 1:20:35 PM 1740 (0x06CC)
    Here is the complete smsts.log: http://1drv.ms/1pwTEBf
    To explain the Problem in Detail:
    The SCCM Primary Site Server and the Clients are in different trusted (bidirectional) forests!
    Everythings working fine in this Scenario, I can install SCCM Agent on the Clients with Manual ccmsetup and with Client Push Installation. Additionally i can deploy Software Updates and so on... only OSD is crashing in the releaserequest step.
    During my Tasksequence new Clients are joined to Domain A while SCCM Primary Site Server is installed in Domain B
    If I change my TS and let the Clients also join Domain B everything works without any Problems and the Tasksequence finish without any Errors.
    My Problem must be related to the different Domains and the forest trust.
    My Setup:
    MP published to DNS in both domains
    Schema Extended in both domains
    System Management Container published and verified in both domains
    ccmsetup Parameters in TS: ccmsetup SMSMP=sccm.domain.b FSP=sccm.domain.b DNSSUFFIX=Domain.b
    Network Access account configured with Domain B account
    Domain Join account has create Computer rights on the OU in Domain A (Domain join is successful)
    DNs conditional forwarders configured in both Domains and DNS resolutin is working in both directions
    Any suggestions?
    Many thanks.
    regards,
    Christian

    Hi Christian,
    So do you actual get an error message in your TS or is it just failing to join Domain B?  (Could be both if the machines fails to join the domain).
    Can you review netsetup.log on the machines after the issue and see what error message you might be getting during the domain join process?
    Also, if it a domain join issue, can you try manually joining to domain B using the same service account?

  • SCCM 2012 SP1 OSD in 802.1X environment

    Dears, 
    we have SCCM 2012 SP1 CU5, and the network team has enabled the CISCO port security (802.1X network authentication) on the desktops VLAN and OSD is not working since then until port security is removed. i've seen some guides regarding how to make SCCM 2007
    OSD, WinPE 3.0 and 802.1X work together like : http://myitforum.com/cs2/blogs/lakey81/archive/2011/07/06/configuring-802-1x-network-authentication-for-winpe-3-0-and-configmgr-deployments.aspx  , but ot's very confusing.
    does anybody have the same scenario with SCCM 2012, WinPE 5.0, and 802.1X . please help me.

    Hello,
    What confused you here? 802.1X authentication is to authenticate before sending network packages. That is why we need import netwrok profile to win pe for anthentication. The point is authenticate, so I think it won't be any difference between
    ConfigMgr 2012 and 2007.          
    Another good article here:
    http://blogs.technet.com/b/deploymentguys/archive/2010/03/02/adding-support-for-802-1x-to-winpe.aspx
    Please also pay attention to the shared document in the blog.
    Please remember to mark the replies as answers if they help and unmark them if they provide no help. If you have feedback for TechNet Subscriber Support, contact [email protected]

  • Task Sequence Failed 0x80091007. SCCM 2012 R2 OSD

    Hi,
    I have multicast deployment issue with Configuration Manager 2012 R2.
    Unicast is working fine, Multicast throwing error 0x80091007. 
    Wait time starts and after 40 to 50 seconds pops up with error 0x80091007
    I have already tried Redistributing and recreating image, trying with different systems, Direct access from DP settings, validating share access and all.
    There is no SMSTS.LOG available on client systems.

    Hi,
    How about MCSISAPI.log?
    Here is a blog talks about this error, you could have a look.
    "Update 19-6-2013: Nick send me a possible solution in comments. What you have to do is make sure you don't have a custom Multicast range set - use the setting "Use IPv4 addresses within any range"
    in the SCCM 2012 multicast tab under Distribution Point properties.
    The default is 239.0.0.1 to 239.0.0.254 - if you have a custom range set - it IGNORES it and uses a random address in 239 range anyways. He has tried to statically set a 239 range on both SCCM multicast and WDS multicast settings - ignores them still uses a
    random address in the 239 range regardless.
    On your Cisco core - if your using that - make sure your ACL's and Rendezvous Point ACL for PIM permits the 239 range. As soon as this was done it's all working. > Will try that myself next month! "
    http://henkhoogendoorn.blogspot.com/2013/02/multicast-error-0x80091007-during.html
    (Note: Microsoft provides third-party contact information to help you find technical support. This contact
    information may change without notice. Microsoft does not guarantee the accuracy of this third-party contact information.)
    Best Regards,
    Joyce
    We
    are trying to better understand customer views on social support experience, so your participation in this
    interview project would be greatly appreciated if you have time.
    Thanks for helping make community forums a great place.

  • SCCM 2012 R2 Tasksequence for VDI Master Image

    Hi
    I'm currently building a ConfigMgr Tasksequence for a RDS VDI solution. At the end of the TS I have a PowerShell Script which prepares the SCCM Client for the master image (delete certs, remove provisioning mode). I would like to use the variable
    SMSTSPostAction for doing the sysprep with a shutdown. But the  machine hangs after rebooting out from the PS Script. Of course the Agent is no longer available but the SMSTSPost Action Variable should start.
    Does anyone have an idea?
    I need to use SCCM as MDT is not an option.

    I fixed this by myself using powershell.
    At the end of the TS I copy a PS Script to the sysprep folder. This script is running as SMSTSPostAction and does the following:
    # Step 1 -Prepare SCCM Client for VDI Deployment
    Get-Service -displayname "SMS Agent Host" | stop-service -Force
    Remove-Item -Path C:\Windows\SMSCFG.INI -force
    Get-childitem -Path cert:\localmachine\sms -DnsName *SMS* | Remove-Item
    Invoke-WmiMethod -Namespace root\CCM -Class SMS_Client -Name SetClientProvisioningMode -ArgumentList $false
    Clear-Host
    Write-Host "Please do not use the VM. SMSTSPostAction is still running!" -foregroundcolor Green
    Write-Host "Waiting several seconds until Sysprep..." -foregroundcolor Green
    Start-Sleep -s 60
    # Step 2 - Sysprep & Shutdown
    C:\Windows\system32\sysprep\sysprep.exe /generalize /oobe /shutdown
    The Maschine reboots at the end of the TS with a success code and runs then the SMSTSPostAction. The SCCM Agent is then well prepared for cloning. Make sure you have set your execution policy right.

  • Deploying the SCCM 2012 Client to WES 7 devices that are locked down with the FBWF using 2007 task sequence via WEDM.

    I'm wondering how people are migrating their embedded devices that are using the FBWF. I've done some googling and it seems like most people are just re-imaging the devices and after migrating a single device i see why. Its not a pretty process. This will
    be a long description but ultimately my question stems more from trying to find a better way to execute the device migration from 2007 to 2012.
    Some back ground on my situation might be in order here. I'm in the process of wrapping up our 2007 to 2012 migration. We have a 2007 infrastructure that was a central server with 2 primaries and 286 secondary site servers. I've consolidated that to a single
    2012 primary site server that hosts all the main roles. There are 2 more servers in the data centers both operating solely as push distribution points I'll refer to them as 2012 01 02 and 03. I'm over half way through the migration and so far haven't needed
    to offload any site roles. There are almost 10,000 clients now reporting to the 2012 site server and almost a 100 field servers pulling content from 2012 02 as their source dp as pull dp is the only way forward for this many devices. I've read the horror stories
    of trying spin up 200 plus push dps. We are running PKI. I'm at the point now where i need to start migrating the Windows Embedded Seven Standard clients that have the 2007 sccm client on them with WEDM for write filter handling.
    What i'm wondering is if anyone has any pointers for me regarding migrating the WES 7 devices. My plan that i've come up with is to somehow script the process using a 2007 WEDM Task Sequence to try and migrate them over to 2012. Things are complicated as
    I need to somehow script the install, the policy checkin, hardware inventory, software inventory, and validate the SCEP client installs before I reboot the device one last time to enable the FBWF. How I handled the SCCM 2007 client install on these devices
    when they were provisioned was to just create a batch file that would sleep for ten minutes then check to see if the inventoryagent.log file had been created yet. I realize now that is inefficient as i can kick off the inventory using a WMI method once the
    client has installed. Also I need to make sure the machine gets its first policy as that is how it creates the communication using PKI through that first policy transfer and that also finalizes the client install. The biggest piece i'm uncertain about in this
    regard is the SCEP client.
    I had to change the SCEP client install from yes to no in the default client settings as we have some Mcaffee servers that can't have the SCEP client on them. I have incremental updates enabled on the collection that has the policy that installs the SCEP
    client but this will take an unknown amount of time unless i force the environment to update as the device starts in 2012 install, or if I could kick off the SCEP isntall... IDK. I'm also wondering if i should keep the device in the migration process until
    i validate it has its proper scep policy applied which I believe can be validated by a registry key somewhere.
    Once the 2012 client gets installed will that cause it to lose its place within the 2007 Task Sequence? Considering its going to take a minimum of 2 reboots I'd normally use the task sequence to handle its progression through the process.
    I'm also considering trying to use an Orchestrator runbook, as that would be a good way to keep track of the migration process as each device migrates. Especially since this might take several seperate scripts.
    I'm going to take a stab at scripting the migration process, but if anyone has any pointers that might make this a less complicated I'd really appreciate it as I've got about 3000 of these devices that need to be migrated over. The other things i've learned
    the hard way is any time you have something this complicated over the course of 3000 devices you will run into unknowns and the failure rate increases. I'm in the precarious position of having to not only build this process out but in some situations have
    it complete in the shortest amount of time possible as we have sites running 24x7. I know the end users behavior all to well and they will just keep hitting the power button sometimes even though their not supposed to so they can get their device functional
    again. In those situations i'd end up, if i'm lucky with a device that no longer has a healthy SCCM client in either environment and the write filter disabled.
    So like i said any pointers anyone could throw my way i'd really appreciate. I manually went through the migration process on a single device for proof of concept and ended up with almost 2 pages of pseudo code for my migration script/scripts.
    Thanks,
    -K.R.

    Hi,
    In R2 there are some new variables you can use to solve this,
    http://ccmexec.com/2014/12/smstsmplistrequesttimeout-value-in-milliseconds/
    In Sp1 though adding a step to sleep for 2-5 minuter after reboot and before the application install step is a common workaround.. a powershell command with "Start-Sleep
    -s 120" should do it. 
    /Jörgen
    -- My System Center blog ccmexec.com -- Twitter
    @ccmexec

  • SCCM 2012 Application Catalog shows ALL advertised to a user independant of the OS they are using

    Within SCCM 2007 if a package was to be made available only to the following platforms, it would only show up on those platforms... If a user was using Win XP and had a package meant ONLY for Win7 advertised to them, they would not see it.... It seems as
    though in CM12, if a user has advertisements meant for XP, Win7, 64 bit, etc... everything appears in teh application catalog. I also understand that the software center is meant for application publishing and not for regular packages as they were in 2007...
    Is there a way to make the packages meant for XP to only appear in the users catalog and NOT show the Win 7 packages?
    As we are in the middle of a Win 7 migration, we need to manage this without a lot of work within AD...

    Hi,
    In Configuration Manager 2012 packages and applications that are made available to users are always displayed in the Application Catalog, the platform requirement is not evaluated until the user actually tries to install the application then the requirements
    are evaluated and the installation will not continue if there the requirements doesn't match the plattform.
    Software Center will display all packages/programs and applications that are deployed as "available" to devices and not users. User targeted will always show up in the Application Catalog..
    Regards,
    Jörgen
    -- My System Center blog ccmexec.com -- Twitter
    @ccmexec

  • SCCM 2012 Recover "User State Recovery Key" after Deletion Policy has removed the key

    I have a computer that was upgraded from Windows XP to 7 using SCCM 2012.  The user's info was captured and restored, but found out a month later that some Outlook Archives are corrupt. 
    I had this happen before on a different user, but found out right away and was able to recover the User State Recovery Key and restore the files. 
    I have looked under Assets and Compliance, User State Migration, but the computer is not listed anymore.
    I have done a file restore of the USMT.MIG file from three weeks ago, but can not extract the users files without the User State Recovery Key.
    I have looked through the SQL tables and have only found the StateEncryptDecryptKey in the StateMigration table which will not work. 
    Environment:
    Windows 2008 R2 SP1 SCCM 2012 Server
    Windows 2008 R2 SP1 SQL 2012 Server
    Any help would be appreciated.
    Thanks,
    Wendell

    It worked! Thank you Jason!
    I restored the server's Storage Folder from "State Migration Point" (USMT Folder) from the same date as the SQL database was restored from.  Shut the SCCM server down while doing the SQL restore.  Turned on the Server and was able
    to pull out the User State Recovery Key. 
    Then reverted back by shutting down the SCCM server and restoring SQL database back to previous backup taken before starting.
    Only issue I'm getting now is that SMS_EN_ADSERVICE_MONITOR has a warning
    8400 Enrollment Point AD Service Control failed to read and configure the registry keys necessary for this component.
    With checking everything out to make sure no issues have arised. I looked through the log adctrl.log and found some more errors about Failed to create instance of ADService Managed Component. error = -2147024809
    Any help would be appreciated.
    Thanks,
    Wendell

  • SCCM 2012 report for all versions on MS lync installed

    Hello,
    I have installed Microsoft Lync 2010 and Lync 2013 on computers in my company and I have different versions
    like 32 and 64 bits, 365 etc I want to make query in SCCM 2012 to tell me the total number of Microsoft Lync clients Installed on win 8 machines in my company, is there a best way to do this I need your advice..
    I have tried various built in reports and not been successful so far.
    Thanks in Advance

    There's a thread already explaining this :
    http://social.technet.microsoft.com/Forums/en-US/f16f1ee8-206c-42a1-af0e-0363c51b840c/how-to-know-total-of-microsoft-lync-installed-on-computers-in-sccm-2012?forum=configmanagergeneral
    Benoit Lecours | Blog: System Center Dudes

  • Previewing images in forms 11g from the server

    Hi All,
    i need your help in this issue please
    i've just migrated my application from forms 6i to forms 11g
    there is a function in my application that i used that previewed images that exists on a network drive that are used in an image gallary
    now i don't have this setup as the application is hosted on the weblogic server
    i want an alternative method that i can use to preview the images from the server
    the old way was:
    read_image_file('.\default_image.jpg','any','preview.image_preview'); --this shows a default image if no image was selected
    if :search_results.file_path is not null then     
         read_image_file(:preview.image_path||'\'||:search_results.file_path,'any','preview.image_preview');     -- this shows the image that we retreived it's name from the database but it exists on the file system
    end if;
    i've configured the webutil but i don't know what method to use
    also another functionality that i lost in the migration is opening a browser window to preview the final article that the editor entered using my application
    the old way was:
    declare
         url varchar2(1000);
    begin     
         url:='http://10.100.100.197:55/allcontent/allcontentimages/'||:SEARCH_RESULTS.FILE_PATH||'';
    WIN_API_SHELL.WinExec('"C:\Program Files\Internet Explorer\IEXPLORE.EXE" '||url||'',
    WIN_API.SW_SHOWMAXIMIZED,TRUE);
    Exception when NO_DATA_FOUND then
    MESSAGE('CAN NOT FIND THE FILE');
    end;
    now ithe WIN_API_SHELL is not working as i'm on the server side and i don't know the alternative
    please advice

    Hello Nivin
    If you want to read an file from local drive or from netwrok drive then before reading images please make sure that do you have full rights and have you mapped that network drive .
    after that you use read_image_file built in(). secondly you configure WEBUTIL package.
    please visit the following link for configuring webutil.
    I configured my webutil package from this link and its worked fine.
    http://www.baigzeeshan.com/2010/01/open-file-dailog-box-example-using.html
    thanks
    G.Yassen

Maybe you are looking for

  • When I create a tablet/desktop/phone version of a site, why are all the pages blank?

    Hello, longtime listener/user, first time caller I've been using Muse since jumping on the Creative Cloud train a couple years ago, but to date all my experience had been in maintaining and updating a desktop version of a couple small sites.  I loved

  • Black in place of album artwork?

    On my iPod nano, some songs display a black space where the album artwork should be (this is NOT the grey music note icon- just black) When I flip the screen to go to Cover Flow, I can see the album artwork for that album. Then when I flip back, the

  • How do I embed a picture in a Discussion message like this?

    I've seen some Discussion messages with embedded graphics, like screengrabs. How do I do this?

  • Labview crashes without any warning or error messages

    Hi, I have been using Labview programs for the last 2 months without any problem. All of a sudden the program has started crashing while running. There are no error messages on the screen. The program runs for long hours and during my intermediate in

  • Enable tab bar

    I have bunch of tab bars in my application. Is there a way to enable a tab bar by clicking on a button or image. Suppose I am on the first tab and there I have a button. When I click on that button it should open up another tab. Thanks.