Screen, dynamic fields

Hello!
I'm developing a screen and I would like to display several radio buttons, according to some selection parameters from the database! The idea is to query the tables that I need and then display several options to the user! I don't know the number of lines that will be return, it deepens on the content of the tables! So the only way is to dynamically add the radio buttons!
Is it possible to add radio buttons on the fly to a screen (se51)? If yes can any one help me?
Best Regards

Hi,
here a short code:
TABLES: MARA, EKKO.
* Material
SELECTION-SCREEN: BEGIN OF LINE.
SELECTION-SCREEN: COMMENT 06(23) T_MARA.
PARAMETERS:       X_MARA RADIOBUTTON GROUP PRI1 DEFAULT 'X'
                  USER-COMMAND DUMMY.
SELECTION-SCREEN: COMMENT 35(15) T_MATNR.
SELECT-OPTIONS    S_MATNR FOR MARA-MATNR MODIF ID DS0.
SELECTION-SCREEN: END   OF LINE.
* Bestellung
SELECTION-SCREEN: BEGIN OF LINE.
SELECTION-SCREEN: COMMENT 06(23) T_EKKO.
PARAMETERS:       X_EKKO RADIOBUTTON GROUP PRI1.
SELECTION-SCREEN: COMMENT 35(15) T_EBELN.
SELECT-OPTIONS    S_EBELN FOR EKKO-EBELN MODIF ID DS1.
SELECTION-SCREEN: END   OF LINE.
AT SELECTION-SCREEN OUTPUT.
  CLEAR: T_MATNR, T_EBELN.
  IF X_MARA = 'X'.
    T_MATNR = 'Materialnummer'.
    LOOP AT SCREEN.
      IF SCREEN-GROUP1 EQ 'DS0'.
        SCREEN-INPUT     = '1'.
        SCREEN-INVISIBLE = '0'.
        MODIFY SCREEN.
      ENDIF.
      IF SCREEN-GROUP1 EQ 'DS1'.
        SCREEN-INPUT     = '0'.
        SCREEN-INVISIBLE = '1'.
        MODIFY SCREEN.
      ENDIF.
    ENDLOOP.
  ENDIF.
  IF X_EKKO = 'X'.
    T_EBELN = 'Bestellnummer'.
    LOOP AT SCREEN.
      IF SCREEN-GROUP1 EQ 'DS0'.
        SCREEN-INPUT     = '0'.
        SCREEN-INVISIBLE = '1'.
        MODIFY SCREEN.
      ENDIF.
      IF SCREEN-GROUP1 EQ 'DS1'.
        SCREEN-INPUT     = '1'.
        SCREEN-INVISIBLE = '0'.
        MODIFY SCREEN.
      ENDIF.
    ENDLOOP.
  ENDIF.
INITIALIZATION.
  T_MARA  = 'Materialien?'.
  T_EKKO  = 'Bestellungen?'.
START-OF-SELECTION.
END-OF-SELECTION.
hope it helps.
regards, Dieter

Similar Messages

  • Get input for 100 dynamic fields in a single screen

    Hi all
    I got one requirement wherein i need to accept input for around 100 dynamic fields in a single screen. screen can scroll down if possible.
    Can anyone tell me whether it is possible. if yes please let me have the sample code.
    Thanks
    Ravindra Suvarna

    Ravi,
    Probably a TAB STRIP might help you.
    Seggregate your 100 fields logically, say 5 groups.
    Have a TAB STRIP CONTROL, with 5 tab strips and place 20 fields in each of the tabs. Each tab strip will have a sub screen.
    Regards,
    Ravi
    Note : Please mark the helpful answers.

  • Changing Field Labels of module pool screen dynamically

    Hi All,
    Can anybody tell me how to change field label of text field in dialog screen dynamically.
    The Screen/Transaction is standard one.
    I have created a Enhancement point for this change in one of PBO module's subroutine for this screen.
    This Field label is defined as a 'Text' field only. We can't change it any more as it is standard one.
    Can anybody tell me the solution for the same.
    I have to change this label value as per some validations and its corresponding text field value will remain as is.
    Thanks,
    Deep.

    Hello,
    I think it is not possible, but try changing the name by Looping on screen table on PBO,
    Bye
    Gabriel

  • How to pass selection screen value to LDB dynamic field.

    Hello everybody,
    In my program, I am using standard LDB(PSJ) for getting data. And there is a requirement that I have to display some dynamic fields on my selection screen like plant , person responsible ( which are mandatory also ) etc. and inside the program I have to fill those dynamic fields for which the user has entered the value in selection screen.
    Could you please tell me how to pass some of selection screen values to ldb dynamic fields before GET statement.
    Thanks !!!
    Regards,
    Mitra

    >
    Pavan Bhamidipati wrote:
    > Hi,
    >
    >
    I have to fill those dynamic fields for which the user has entered the value in selection screen.
    >
    >
    > This means that the user is going to enter the values in the selection screen for the dynamic field values so
    >
    > SET PARAMETERID 'XYZ' FIELD p_field.
    >
    > where p_field is a parameter on the selection screen
    >
    > Regards
    > Pavan
    You can capture the values selected through the dynamic selections using some of the functions modules below, just search the forum for the below FM's, perhaps you can find some sample code
    FREE_SELECTIONS_EX_2_RANGE
    FREE_SELECTIONS_EX_2_WHERE
    FREE_SELECTIONS_RANGE_2_EX
    FREE_SELECTIONS_RANGE_2_WHERE
    FREE_SELECTIONS_WHERE_2_EX
    FREE_SELECTIONS_WHERE_2_RANGE

  • Adding fields on selection screen dynamically

    Hi all,
    Can we add some fields to selection screen dynamically on pushbutton click?
    Regards,
    Dnyanesh

    just have look below code
    REPORT zrsdvsr1
           LINE-SIZE 220
           LINE-COUNT 65(5).
    TYPE-POOLS : slis.
    TABLES
    TABLES: vbak.
    DATA DECLARATIONS
    Ranges
    RANGES: r_posnr FOR vbap-posnr.
    DATA: BEGIN OF t_veramt OCCURS 0,
            vbeln TYPE vbap-vbeln,
            posnr TYPE vbap-posnr,
            matnr TYPE vbap-matnr,
            netwr TYPE vbap-netwr,
            mwsbp TYPE vbap-mwsbp,
          END OF t_veramt.
    DATA: BEGIN OF t_disamt OCCURS 0,
            vbeln TYPE vbap-vbeln,
            posnr TYPE vbap-posnr,
            matnr TYPE vbap-matnr,
            netwr TYPE vbap-netwr,
            mwsbp TYPE vbap-mwsbp,
            netwr_v TYPE vbap-netwr,
            mwsbp_v TYPE vbap-mwsbp,
            disc_val TYPE vbap-mwsbp,
          END OF t_disamt.
    *&   ALV FIELDS
    DATA : alv_fcat TYPE slis_t_fieldcat_alv WITH HEADER LINE,
           alv_layout TYPE slis_layout_alv.
    SELECTION SCREEN
    SELECTION-SCREEN BEGIN OF BLOCK b1 WITH FRAME TITLE text-001.
    PARAMETERS:  p_ver RADIOBUTTON GROUP g1 USER-COMMAND rad DEFAULT 'X',
                 p_sab RADIOBUTTON GROUP g1 .
    SELECTION-SCREEN END OF BLOCK b1.
    SELECTION-SCREEN BEGIN OF BLOCK b2 WITH FRAME TITLE text-002.
    SELECT-OPTIONS: s_vbeln FOR vbak-vbeln NO INTERVALS MODIF ID gr1.
    PARAMETERS:    p_dwfile TYPE  rlgrap-filename
                   DEFAULT 'C:\test1.txt' MODIF ID gr2,         "#EC NOTEXT
                   p_upfile TYPE  rlgrap-filename
                   DEFAULT 'C:\test.txt' MODIF ID gr3.          "#EC NOTEXT
    SELECTION-SCREEN END OF BLOCK b2.
    AT SELECTION-SCREEN ON VALUE-REQUEST FOR p_upfile.
    **************F4 Help For Input File Name****************************
      CALL FUNCTION 'F4_FILENAME'
           EXPORTING
                program_name  = syst-cprog
                dynpro_number = syst-dynnr
                field_name    = 'C:\'
           IMPORTING
                file_name     = p_upfile.
    AT SELECTION-SCREEN ON VALUE-REQUEST FOR p_dwfile.
    **************F4 Help For Input File Name****************************
      CALL FUNCTION 'F4_FILENAME'
           EXPORTING
                program_name  = syst-cprog
                dynpro_number = syst-dynnr
                field_name    = 'C:\'
           IMPORTING
                file_name     = p_dwfile.
    AT SELECTION-SCREEN OUTPUT.
      LOOP AT SCREEN.
        IF  p_sab = 'X'.
          IF screen-group1 = 'GR1' OR screen-group1 = 'GR2'.
            screen-active = '0'.
            screen-invisible = '1'.
          ELSE.
            screen-active = '1'.
            screen-invisible = '0'.
          ENDIF.
          MODIFY SCREEN.
        ELSE.
          IF screen-group1 = 'GR3'.
            screen-active = '0'.
            screen-invisible = '1'.
          ELSE.
            screen-active = '1'.
            screen-invisible = '0'.
          ENDIF.
          MODIFY SCREEN.
        ENDIF.
      ENDLOOP.
    START-OF-SELECTION
    START-OF-SELECTION.
    Check Radio Button
      IF p_ver = 'X'.
        PERFORM get_details_open_so_vertex.
      ELSE.
        PERFORM get_details_open_so.
      ENDIF.
    Display the output.
      PERFORM diplay_report .
    regards
    vinod

  • Dynamic field on the output screen

    Hi All,
    I have a requirement to create the dynamic field on the output screen.
    In the basic list I am displaying the production order details like
    check box, production order , materials, quantity, etc.
    If I select the particular check box , the quantity pertaining to that check box line as to display on the dynamic field. If I select more than one check box, then the cummilative quantity of all the production orders has to display on the dynamic field.
    Thanks in advance.
    Ramesh.

    hi,
      you can define a dinamic fields depending on selection of check box.
      Go through the below code. I think it may help you.
    PARAMETERS:
      P_CB1 AS CHECKBOX,
      P_CB2 AS CHECKBOX,
      P_A TYPE I MODIF ID XXX DEFAULT ' ',
      P_B TYPE I MODIF ID YYY DEFAULT ' '.
    DATA:
      W_C1,
      W_C2.
    AT SELECTION-SCREEN OUTPUT.
      LOOP AT SCREEN.
        IF SCREEN-GROUP1 = 'XXX'.
          SCREEN-ACTIVE = 0.
          MODIFY SCREEN.
        ELSEIF SCREEN-GROUP1 = 'YYY'.
          SCREEN-ACTIVE = 0.
          MODIFY SCREEN.
        ENDIF.
      ENDLOOP.
      IF P_CB1 EQ 'X'.
        LOOP AT SCREEN.
          IF SCREEN-GROUP1 = 'XXX'.
            SCREEN-ACTIVE = 1.
            SCREEN-INPUT  = 1.
            SCREEN-OUTPUT = 1.
            SCREEN-INVISIBLE = 0.
            MODIFY SCREEN.
          ENDIF.
        ENDLOOP.
      ENDIF.
      IF P_CB2 EQ 'X'.
        LOOP AT SCREEN.
          IF SCREEN-GROUP1 = 'YYY'.
            SCREEN-ACTIVE = 1.
            SCREEN-INPUT  = 1.
            SCREEN-OUTPUT = 1.
            SCREEN-INVISIBLE = 0.
            MODIFY SCREEN.
          ENDIF.
        ENDLOOP.
      ENDIF.

  • Dynamic fields creation on selection screen

    Good evening everybody!
    I've got the following problem for solving:
    Imagine the following situation:
    on the selection-screen there are some input fields in one line and a button after them. By pressing that button (e.g. it's name is "Add line") the same fields should be duplicated so many times as many times that button pressed. By pressing another button (e.g. it's name is "Delete line") one last line should be deleted. The mechanism is similar to adding lines in a screen table. What is the solution of this problem?
    So: by pressing an "Add line" button on a screen identical fields should be created on the same selection-screen and deleted by pressing "Delete line".
    Thanks in advance!

    Here's a way to do it.
    DEFINE aline.
      selection-screen: begin of line.
      parameters: inp&1(5) type c modif id l&1.
      selection-screen position 15.
      parameters: inp10&1(5) type c modif id l&1.
      selection-screen pushbutton 25(5) pb_&1 user-command add
         modif id a&1.
      selection-screen pushbutton 31(5) pb_10&1 user-command del
         modif id d&1.
      selection-screen end   of line.
    END-OF-DEFINITION.
    TABLES: sscrfields.
    DATA:
      max_lines         TYPE i VALUE 20,
      fldname(60)       TYPE c,
      lines(2)          TYPE n VALUE 1,
      cnt(2)            TYPE n VALUE 1.
    FIELD-SYMBOLS:
      <fld>     TYPE ANY.
    aline 01.
    aline 02.
    aline 03.
    aline 04.
    aline 05.
    aline 06.
    aline 07.
    aline 08.
    aline 09.
    aline 10.
    aline 11.
    aline 12.
    aline 13.
    aline 14.
    aline 15.
    aline 16.
    aline 17.
    aline 18.
    aline 19.
    aline 20.
    *---------------------------------------------------- Push Button
    AT SELECTION-SCREEN.
      CASE sscrfields-ucomm.
        WHEN 'ADD'.
          CHECK lines LT max_lines.
          lines = lines + 1.
        WHEN 'DEL'.
          CHECK lines GT 1.
          lines = lines - 1.
      ENDCASE.
    AT SELECTION-SCREEN OUTPUT.
      LOOP AT SCREEN.
        IF screen-group1 CP 'A*'.
          IF screen-group1+1(2) NE lines.
            screen-active = 0.
          ELSE.
            IF lines LT max_lines.
              screen-active = 1.
            ELSE.
              screen-active = 0.
            ENDIF.
          ENDIF.
        ENDIF.
        IF screen-group1 CP 'D*'.
          IF screen-group1+1(2) NE lines.
            screen-active = 0.
          ELSE.
            IF lines = 1.
              screen-active = 0.
            ELSE.
              screen-active = 1.
            ENDIF.
          ENDIF.
        ENDIF.
        IF screen-group1 CP 'L*'.
          IF screen-group1+1(2) GT lines.
            screen-active = 0.
          ELSE.
            screen-active = 1.
          ENDIF.
        ENDIF.
        MODIFY SCREEN.
      ENDLOOP.
    INITIALIZATION.
      cnt = 1.
      WHILE cnt LE max_lines.
        CONCATENATE 'PB_' cnt INTO fldname.
        ASSIGN (fldname) TO <fld>.
        <fld> = 'Add'.
        CONCATENATE 'PB_10' cnt INTO fldname.
        ASSIGN (fldname) TO <fld>.
        <fld> = 'Del'.
        cnt = cnt + 1.
      ENDWHILE.
    Edited by: Paul Chapman on Jul 1, 2008 1:06 PM

  • How to create the selection screen dynamically

    Hi,
    I have a requirement to create the selection screen Dynamically. All the fields that should appear on the selection screen will be available in a custom table. So, based on the entries available in the Z tables, the selection screen should be built. Eg. If there are 10 records available in the Z table, the selection screen should consist of 10 fields. If there are 100 entries, the Selection screen should contain 100 fields. and the logic to build this selection screen should be carried out dynamically in the program.
    Could anyone of you please share the valuable inputs on this. If anyone has the sample code to do this, please share.
    Thanks in advance.
    Regards,
    Paddu.

    Hi,
    Kindly go through this sample program below:
    DEMO_LIST_FORMAT_INPUT *and
    check this function module:
    FREE_SELECTIONS_DIALOG *.
    Hope it helps
    Regards
    Mansi

  • Dynamic field value in Sales order item table control

    Hi
    I need to find the VBAP-VKAUS (Usage indicator) field value in run time of the creation of sale order ...these values stored in the  table TVLV.
    when i debug the program SAPMV45A in the screen 4900 this VBAP-VKAUS value gets empty in structure VBAP even though i can see other values like MATNR etc...
    this field is configurable (dynamic) field and not appear for all the ordertypes.
    i need to pass this VBAP-VKAUS  value to KOMPD-VKAUS
    Thru user-exit..so please let me know if somebody knows how to find this VBAP-VKAUS  value.
    Thanks in advance
    Madi

    hi,
    Plz Check the struc KOMP/KOMK. Let me know, if this helped.
    Rgds,
    Raghu.

  • Dynamic field in select query

    Hi Team,
    I have to select dynamic fields from database table GLT0.
    This depends on period value given on screen.
    If period is 01 then fields will be hsl01.
    If period is 02 then fields will be hsl01 and hsl02.
    If period is 03 then fields will be hsl01,hsl02 and hsl03 .
    so on...till 12..
    My code is throwing exception at select query.
    "Error in module RSQL of the database interface."
    My code :
    *"      Type declaration to store field name as per given period
    TYPES : BEGIN OF y_fieldname        ,
               fieldname(10)  TYPE c    ,
             END OF y_fieldname         .
    data  t_fieldname  TYPE  STANDARD TABLE OF y_fieldname   .
      DO p_monat TIMES.
         clear w_count .
          MOVE sy-index TO w_count
          IF sy-index LE c_9.
            CONCATENATE c_hsl
                        c_0
                        w_count
            INTO      e_fieldname-fieldname.
            APPEND e_fieldname TO t_fieldname.
          ELSE.
            CONCATENATE c_hsl
                        w_count
            INTO     e_fieldname-fieldname.
            APPEND e_fieldname TO t_fieldname.
          ENDIF.
        ENDDO.
      Get Local Currency Amounts
      from table glt0 depending on period
        SELECT (t_fieldname)
          FROM glt0
          INTO TABLE t_glto_with_saknr
          FOR ALL ENTRIES IN t_bukrs
         WHERE rldnr EQ c_00
           AND rrcty EQ c_0
           AND rvers EQ c_001
           AND bukrs EQ t_bukrs-bukrs
           AND ryear EQ p_gjahr
           AND racct IN r_saknr.
    Please guide me.
    Thanking u in advance.
    Sangeeta Verma

    Hi Asik,
    I m selecting all fields now as suggestd by u so in one record i have hsl01 to hsl12.
    I have to calculate balance into e_glt0_bal-bal .This balance is summation of e_glt0_bal-hsl01 till  e_glt0_bal-hsl12 (depending on monat).
    I m using logic in process then
    my code now :
    data:    w_monat_bal type string  .
              DO p_monat TIMES.
                MOVE c_01 TO w_count .
                CONCATENATE 'e_glt0_bal-hsl'
                             w_count
                       INTO w_monat_bal.
                ASSIGN w_monat_bal TO <fs_monat_bal>.
                e_glt0_bal-bal = e_glt0_bal-bal + <fs_monat_bal>.
                w_count = w_count + c_01.
              ENDDO.
    But <fs_monat_bal> can not be added.
    Giving exception :
    Unable to interpret "e_glt0_bal-hsl01" as a number.
    If I do <fs_monat_bal> type GLT0-hslvt instead to type any
    Then assigning from w_monat_bal  is not possible.

  • Reg: Dynamic Field catalog in ALV

    Hi ,
    Can any one guide me to build a dynamic field catalog in ALV report?
    Below is the format which i expect..........
    Material    |     Plant1    |    Plant2    |    Plant3    | ....................|    Plant 20      |
    Qty
    Val
    Qty
    Val
    Qty
    Val
    Qty
    Val
    The plant 1 to 20 has to be brought dynamically as headings from T001W table. (Horizontally populate)
    Below each plant i need sub-headings "QTY" and "VAL".                                  (Horizontally populate)
    List of Materials should be brought vertically from MARA table.                          (Vertically populate)
    Can anyone suggest how to bring out this format for populating data accordingly into the o/p format?
    Ur help will be appreciated.
    Thanks,
    K.S.Kannan

    your part of the code is present in routine
    perform dynamic_table.
    *& Report ZCS_NAC_MAT_CHARACTERISTICS
    2/ Description ...: Business requirement is to get all materials
    without any characteristic values maintained in SAP
    which are given in the selection screen.
    REPORT znac_material_char.
    TYPE-POOLS : abap,
    slis.
    TABLES : kssk,
    klah,
    mara,
    makt,
    cabn,
    t134,
    t023.
    DATA : i_fieldcat TYPE slis_t_fieldcat_alv ,
    wa_fieldcat TYPE slis_fieldcat_alv.
    DATA : w_layout TYPE slis_layout_alv.
    DATA : st_layout TYPE slis_layout_alv.
    DATA : t_header TYPE slis_t_listheader,
    w_header TYPE slis_listheader.
    TYPES : BEGIN OF ty_cabn,
    atinn TYPE cabn-atinn,
    atnam TYPE cabn-atnam,
    END OF ty_cabn.
    DATA : i_cabn TYPE STANDARD TABLE OF ty_cabn WITH HEADER LINE.
    DATA : w_cabn LIKE i_cabn.
    TYPES : BEGIN OF ty_ausp,
    objek TYPE ausp-objek,
    atinn TYPE ausp-atinn,
    klart TYPE ausp-klart,
    END OF ty_ausp.
    DATA : i_ausp TYPE STANDARD TABLE OF ty_ausp WITH HEADER LINE.
    DATA : w_ausp LIKE i_ausp.
    TYPES : BEGIN OF ty_mara,
    matnr TYPE mara-matnr,
    mtart TYPE mara-mtart,
    matkl TYPE mara-matkl,
    prdha TYPE mara-prdha,
    mstae TYPE mara-mstae,
    mstde TYPE mara-mstde,
    END OF ty_mara.
    DATA : i_mara TYPE STANDARD TABLE OF ty_mara WITH HEADER LINE.
    DATA : w_mara LIKE i_mara.
    DATA : i_mara_temp TYPE STANDARD TABLE OF ty_mara WITH HEADER LINE.
    DATA : w_mara_temp LIKE i_mara_temp.
    TYPES :BEGIN OF ty_data,
    atnam TYPE cabn-atnam,
    atinn TYPE cabn-atinn,
    objek TYPE ausp-objek,
    klart TYPE ausp-klart,
    matnr TYPE mara-matnr,
    maktx TYPE makt-maktx,
    mtart TYPE mara-mtart,
    matkl TYPE mara-matkl,
    prdha TYPE mara-prdha,
    mstae TYPE mara-mstae,
    mstde TYPE mara-mstde,
    END OF ty_data.
    DATA : i_data TYPE STANDARD TABLE OF ty_data WITH HEADER LINE.
    DATA : w_data LIKE i_data.
    DATA : i_class TYPE STANDARD TABLE OF sclass WITH HEADER LINE.
    DATA : w_class LIKE i_class.
    DATA : i_class_temp TYPE STANDARD TABLE OF sclass WITH HEADER LINE.
    DATA : w_class_temp LIKE i_class_temp.
    DATA : i_objdata TYPE STANDARD TABLE OF clobjdat WITH HEADER LINE.
    DATA : w_objdata LIKE i_objdata.
    TYPES : BEGIN OF ty_objdata_temp.
    TYPES: matnr TYPE mara-matnr.
    TYPES: maktx TYPE makt-maktx.
    INCLUDE STRUCTURE clobjdat.
    TYPES : prdha TYPE mara-prdha.
    TYPES : mstde TYPE mara-mstde.
    TYPES : END OF ty_objdata_temp.
    DATA : i_objdata_temp TYPE STANDARD TABLE OF ty_objdata_temp WITH HEADER LINE.
    DATA : w_objdata_temp LIKE i_objdata_temp.
    FIELD-SYMBOLS: <t_dyntable> TYPE STANDARD TABLE,
    <fs_dyntable>,
    <fs_fldval> TYPE ANY.
    DATA: t_newtable TYPE REF TO data,
    t_newline TYPE REF TO data,
    fs_fldcat TYPE slis_t_fieldcat_alv,
    t_fldcat1 TYPE lvc_t_fcat,
    wa_it_fldcat TYPE lvc_s_fcat,
    wa_colno(2) TYPE n,
    wa_flname(30) TYPE c.
    DATA: fieldname(20) TYPE c.
    DATA: fieldvalue(40) TYPE c.
    DATA: index(3) TYPE c,
    v_time(60) TYPE c.
    DATA: wa_cat LIKE LINE OF fs_fldcat.
    CONSTANTS : c_nac TYPE klah-class VALUE 'NAC',
    c_klart TYPE ausp-klart VALUE '001',
    c_check TYPE c VALUE 'X' .
    SELECTION-SCREEN BEGIN OF BLOCK b1 WITH FRAME TITLE text-000.
    SELECTION-SCREEN BEGIN OF LINE.
    SELECTION-SCREEN COMMENT (28) text-001 .
    SELECT-OPTIONS: s_atnam FOR cabn-atnam NO INTERVALS OBLIGATORY. " Characteristic name
    SELECTION-SCREEN END OF LINE.
    SELECTION-SCREEN END OF BLOCK b1 .
    SELECTION-SCREEN BEGIN OF BLOCK b2 WITH FRAME TITLE text-002.
    SELECT-OPTIONS: s_matnr FOR mara-matnr. " material Number
    SELECT-OPTIONS: s_mtart FOR mara-mtart. " material type
    SELECT-OPTIONS: s_matkl FOR mara-matkl. " material type
    SELECT-OPTIONS: s_mstae FOR mara-mstae. " X-Plant material status
    PARAMETERS : s_date LIKE sy-datum OBLIGATORY DEFAULT sy-datum . " date
    SELECTION-SCREEN END OF BLOCK b2 .
    AT SELECTION-SCREEN ON s_atnam.
    SELECT SINGLE * FROM cabn WHERE atnam IN s_atnam.
    IF sy-subrc 0.
    MESSAGE text-003 TYPE 'E'.
    ENDIF.
    AT SELECTION-SCREEN ON s_matnr.
    SELECT SINGLE * FROM mara WHERE matnr IN s_matnr.
    IF sy-subrc 0.
    MESSAGE text-004 TYPE 'E'.
    ENDIF.
    AT SELECTION-SCREEN ON s_mtart.
    SELECT SINGLE * FROM t134 WHERE mtart IN s_mtart.
    IF sy-subrc 0.
    MESSAGE text-005 TYPE 'E'.
    ENDIF.
    AT SELECTION-SCREEN ON s_matkl.
    SELECT SINGLE * FROM t023 WHERE matkl IN s_matkl.
    IF sy-subrc 0.
    MESSAGE text-006 TYPE 'E'.
    ENDIF.
    START-OF-SELECTION.
    PERFORM get_data.
    PERFORM get_data_keydate.
    PERFORM material_all_charname.
    PERFORM get_classification.
    PERFORM dynamic_table.
    *& Form dynamic_table
    text
    --> p1 text
    <-- p2 text
    FORM dynamic_table.
    PERFORM fieldcatalog.
    PERFORM dynamic_table_create.
    PERFORM final_data.
    PERFORM final_fieldcatalog.
    PERFORM layout_build.
    PERFORM grid_display.
    ENDFORM. " fieldcat
    *& Form layout_build
    text
    FORM layout_build .
    st_layout-zebra = c_check.
    st_layout-no_vline = ''.
    st_layout-colwidth_optimize = c_check.
    st_layout-detail_popup = c_check.
    st_layout-detail_initial_lines = c_check.
    st_layout-detail_titlebar = text-021.
    ENDFORM. " layout_build
    *& Form alv_top_of_page
    text
    FORM alv_top_of_page.
    REFRESH t_header.
    CLEAR t_header.
    w_header-typ = 'H'. "H=Header, S=Selection, A=Action
    w_header-key = ' '.
    w_header-info = text-019.
    APPEND w_header TO t_header.
    CONCATENATE sy-datum4(2) '-' sy-datum6(2) '-' sy-datum0(4) ' / ' sy-uzeit0(2) ':' sy-uzeit2(2) ':' sy-uzeit4(2) INTO v_time.
    w_header-typ = 'S'. "H=Header, S=Selection, A=Action
    w_header-key = text-020.
    w_header-info = v_time.
    APPEND w_header TO t_header.
    CALL FUNCTION 'REUSE_ALV_COMMENTARY_WRITE'
    EXPORTING
    it_list_commentary = t_header.
    ENDFORM. "alv_top_of_page
    *& Form grid_display
    text
    --> p1 text
    <-- p2 text
    FORM grid_display .
    CALL FUNCTION 'REUSE_ALV_GRID_DISPLAY'
    EXPORTING
    i_callback_program = sy-repid
    i_callback_top_of_page = 'ALV_TOP_OF_PAGE'
    it_fieldcat = fs_fldcat
    is_layout = st_layout
    i_default = c_check
    i_save = 'A'
    it_events = v_events[]
    TABLES
    t_outtab = <t_dyntable>.
    ENDFORM. " grid_display
    *& Form FINAL_FIELDCATALOG
    text
    --> p1 text
    <-- p2 text
    FORM final_fieldcatalog .
    wa_cat-fieldname = text-009.
    wa_cat-seltext_m = text-015.
    wa_cat-outputlen = 18.
    APPEND wa_cat TO fs_fldcat.
    wa_cat-fieldname = text-011.
    wa_cat-seltext_m = text-016.
    wa_cat-outputlen = 40.
    APPEND wa_cat TO fs_fldcat.
    LOOP AT s_atnam.
    CLEAR wa_cat.
    wa_cat-fieldname = s_atnam-low.
    wa_cat-seltext_m = s_atnam-low.
    wa_cat-outputlen = '15'.
    APPEND wa_cat TO fs_fldcat.
    ENDLOOP.
    wa_cat-fieldname = text-012.
    wa_cat-seltext_m = text-017.
    wa_cat-outputlen = 18.
    APPEND wa_cat TO fs_fldcat.
    wa_cat-fieldname = text-013.
    wa_cat-seltext_m = text-018.
    wa_cat-outputlen = 8.
    APPEND wa_cat TO fs_fldcat.
    ENDFORM. " FINAL_FIELDCATALOG
    *& Form FIELDCATALOG
    text
    --> p1 text
    <-- p2 text
    FORM fieldcatalog .
    wa_it_fldcat-fieldname = text-009.
    wa_it_fldcat-datatype = text-010.
    wa_it_fldcat-intlen = 18.
    APPEND wa_it_fldcat TO t_fldcat1.
    wa_it_fldcat-fieldname = text-011.
    wa_it_fldcat-datatype = text-010.
    wa_it_fldcat-intlen = 40.
    APPEND wa_it_fldcat TO t_fldcat1.
    LOOP AT s_atnam.
    CLEAR wa_it_fldcat.
    wa_it_fldcat-fieldname = s_atnam-low.
    wa_it_fldcat-datatype = text-010.
    wa_it_fldcat-intlen = 30.
    APPEND wa_it_fldcat TO t_fldcat1.
    ENDLOOP.
    wa_it_fldcat-fieldname = text-012.
    wa_it_fldcat-datatype = text-010.
    wa_it_fldcat-intlen = 18.
    APPEND wa_it_fldcat TO t_fldcat1.
    wa_it_fldcat-fieldname = text-013.
    wa_it_fldcat-datatype = text-014.
    wa_it_fldcat-intlen = 8.
    APPEND wa_it_fldcat TO t_fldcat1.
    ENDFORM. " FIELDCATALOG
    *& Form DYNAMIC_TABLE_CREATE
    text
    --> p1 text
    <-- p2 text
    FORM dynamic_table_create .
    Create dynamic internal table and assign to FS
    CALL METHOD cl_alv_table_create=>create_dynamic_table
    EXPORTING
    it_fieldcatalog = t_fldcat1
    IMPORTING
    ep_table = t_newtable.
    ASSIGN t_newtable->* TO <t_dyntable>.
    Create dynamic work area and assign to FS
    CREATE DATA t_newline LIKE LINE OF <t_dyntable>.
    ASSIGN t_newline->* TO <fs_dyntable>.
    ENDFORM. " DYNAMIC_TABLE_CREATE
    *& Form FINAL_DATA
    text
    --> p1 text
    <-- p2 text
    FORM final_data .
    LOOP AT i_objdata_temp INTO w_objdata_temp.
    *assign w_objdata_temp-matnr to <fs_dyntable>.
    AT NEW matnr.
    wa_flname = text-009.
    fieldvalue = w_objdata_temp-matnr.
    CONDENSE fieldvalue NO-GAPS.
    ASSIGN COMPONENT wa_flname
    OF STRUCTURE <fs_dyntable> TO <fs_fldval>.
    <fs_fldval> = fieldvalue.
    ENDAT.
    wa_flname = text-011.
    fieldvalue = w_objdata_temp-maktx.
    CONDENSE fieldvalue NO-GAPS.
    ASSIGN COMPONENT wa_flname
    OF STRUCTURE <fs_dyntable> TO <fs_fldval>.
    <fs_fldval> = fieldvalue.
    wa_flname = w_objdata_temp-atnam.
    fieldvalue = w_objdata_temp-ausp1.
    CONDENSE fieldvalue NO-GAPS.
    ASSIGN COMPONENT wa_flname
    OF STRUCTURE <fs_dyntable> TO <fs_fldval>.
    <fs_fldval> = fieldvalue.
    wa_flname = text-012.
    fieldvalue = w_objdata_temp-prdha.
    CONDENSE fieldvalue NO-GAPS.
    ASSIGN COMPONENT wa_flname
    OF STRUCTURE <fs_dyntable> TO <fs_fldval>.
    <fs_fldval> = fieldvalue.
    wa_flname = text-013.
    fieldvalue = w_objdata_temp-mstde.
    CONDENSE fieldvalue NO-GAPS.
    ASSIGN COMPONENT wa_flname
    OF STRUCTURE <fs_dyntable> TO <fs_fldval>.
    <fs_fldval> = fieldvalue.
    AT END OF matnr.
    APPEND <fs_dyntable> TO <t_dyntable>.
    ENDAT.
    ENDLOOP.
    ENDFORM. " FINAL_DATA
    *& Form GET_CLASSIFICATION
    text
    --> p1 text
    <-- p2 text
    FORM get_classification .
    LOOP AT i_data INTO w_data.
    SELECT SINGLE * FROM klah WHERE class = c_nac.
    IF sy-subrc = 0.
    IF w_data-mstde >= klah-vondt.
    CALL FUNCTION 'CLAF_CLASSIFICATION_OF_OBJECTS'
    EXPORTING
    class = c_nac
    classtext = c_check
    classtype = c_klart
    clint = 0
    features = c_check
    language = sy-langu
    object = w_data-objek
    TABLES
    t_class = i_class
    t_objectdata = i_objdata
    EXCEPTIONS
    no_classification = 1
    no_classtypes = 2
    invalid_class_type = 3
    OTHERS = 4.
    LOOP AT i_class INTO w_class.
    MOVE w_class TO w_class_temp.
    APPEND w_class_temp TO i_class_temp.
    ENDLOOP .
    LOOP AT s_atnam.
    READ TABLE i_objdata INTO w_objdata WITH KEY atnam = s_atnam-low.
    IF sy-subrc = 0.
    MOVE w_data-matnr TO w_objdata_temp-matnr.
    MOVE w_data-maktx TO w_objdata_temp-maktx.
    MOVE-CORRESPONDING w_objdata TO w_objdata_temp.
    MOVE w_data-prdha TO w_objdata_temp-prdha.
    MOVE w_data-mstde TO w_objdata_temp-mstde.
    APPEND w_objdata_temp TO i_objdata_temp.
    ENDIF.
    ENDLOOP.
    ENDIF.
    ENDIF.
    ENDLOOP.
    ENDFORM. " GET_CLASSIFICATION

  • Dynamic field in select statment.

    Hello,
    I created a report in which i have two checkboxes in the selection screen. The first checkbox is for the option to bring or not, initial purchase requisitions (BANFN) from EKPO and the second is to bring initial or not, RFQs
    (ANFNR). I want the select statment to have this form:
    select ...
    from ekpo
    into g_table
    where ..
    and dynamic field = " ".
    Can this be done ?
    i tried to put it as a string but it didnt work. (data: dynamic field type string value "EKPO-BANFN")
    P.S i know that it can be by writing the same select code twice.
    I just wonder if this can be done by this way
    \Regards.

    Hey Nick,
    I have more conditions than the one i said before , should all be in the lv_where_clause ?
    check my code.
    DATA: G_CHBFLD type STRING.
    G_CHBFLD = 'P~BANFN = '' " '.
    FORM SELECT_DATA_EKPO_EKKO.
      SELECT  .....
          FROM EKPO AS P INNER JOIN EKKO AS K
            ON PEBELN = KEBELN
              INTO CORRESPONDING FIELDS OF TABLE GT_EKPOEKKO
                WHERE K~EBELN IN S_EBELN
                AND K~AEDAT IN S_AEDAT
                AND K~BSTYP IN S_BSTYP
                and ( G_CHBFLD ) .   -
    > //DEBUGER ")" is not a valid comparison operator. comparison operator.

  • AT SELECTION-SCREEN-ON FIELD  event IN ALV

    Hai all,
               Is there any event in ALV similar to AT SELECTION-SCREEN-ON FIELD  .
    if so how can this be achieved ,pls give me an example .
    Regards,
    Dev

    Sap provides a set of ALV (ABAP LIST VIEWER) function modules which can be put into use to embellish the output of a report. This set of ALV functions is used to enhance the readability and functionality of any report output. Cases arise in sap when the output of a report contains columns extending more than 255 characters in length. In such cases, this set of ALV functions can help choose selected columns and arrange the different columns from a report output and also save different variants for report display. This is a very efficient tool for dynamically sorting and arranging the columns from a report output. The report output can contain upto 90 columns in the display with the wide array of display options.
    The commonly used ALV functions used for this purpose are;
    1. REUSE_ALV_VARIANT_DEFAULT_GET
    2. REUSE_ALV_VARIANT_F4
    3. REUSE_ALV_VARIANT_EXISTENCE
    4. REUSE_ALV_EVENTS_GET
    5. REUSE_ALV_COMMENTARY_WRITE
    6. REUSE_ALV_FIELDCATALOG_MERGE
    7. REUSE_ALV_LIST_DISPLAY
    8. REUSE_ALV_GRID_DISPLAY
    9. REUSE_ALV_POPUP_TO_SELECT
    The different steps used for getting the above function modules into use are:
    Step 1
    DATA DECLARATION
    Sap standard type pools: SLIS , KKBLO .
    Sap standard tables types taken from the type pools are: SLIS_LAYOUT_ALV ,
    SLIS_T_FIELDCAT_ALV,
    SLIS_T_LISTHEADER,
    SLIS_T_EVENT,
    SLIS_SELFIELD.
    Internal tables to used in the program declared based on the above table types
    DATA: I_LAYOUT TYPE SLIS_LAYOUT_ALV,
    I_FIELDTAB TYPE SLIS_T_FIELDCAT_ALV,
    I_HEADING TYPE SLIS_T_LISTHEADER,
    I_EVENTS TYPE SLIS_T_EVENT.
    TYPES: KKBLO_SELFIELD TYPE SLIS_SELFIELD.
    Step 2 (Optional)
    SELECTING THE VARIANTS FOR INITIAL LIST DISPLAY (DEFAULT VARIANT)
    The variants in the list display can be both user-specific and general. The user can programmatically set the initial (default) variant for list display.
    The default variant can be found using the function module 'REUSE_ALV_VARIANT_DEFAULT_GET'.
    Sample code:
    CALL FUNCTION 'REUSE_ALV_VARIANT_DEFAULT_GET'
    EXPORTING
    i_save = variant save condition ( A=all, U = user-specific )
    CHANGING
    cs_variant = internal table containing the program name (and the default variant---optional )
    EXCEPTIONS
    not_found = 2.
    The user can also choose from the list of existing variants using the function module ‘REUSE_ALV_VARIANT_F4’.
    Step 3
    DEFININING OUTPUT CHARACTERISTICS: PREPARING DISPLAY FIELDS CATALOG
    A field catalog is prepared using the internal table (I_FIELDCAT) of type SLIS_T_FIELDCAT_ALV. Field catalog containing descriptions of the list output fields (usually a subset of the internal output table fields).
    A field catalog is required for every ALV list output to add desired functionality (i.e. Key, Hotspot, Specific headings, Justify, Col. position etc) to certain fields of the output. If not mentioned specifically, then the defaults are taken. The possible values and defaults are listed below.
    The field catalog for the output table is built-up in the caller's coding. The build-up can be completely or partially automated by calling the REUSE_ALV_FIELDCATALOG_MERGE module.
    The minimal field catalog is documented below. This can be done in a routine using a local variable. The user can use the other optional parameters to assign output attributes to different fields in the output, which differ from the default.
    A field catalog need not be built-up and passed explicitly only under the following conditions:
    1. The internal table to be output has the same structure as a Data Dictionary structure which is referred to in the internal table declaration using LIKE or INCLUDE STRUCTURE. In this case the attributes of the different fields is taken directly from the table and the attributes (key fields, length, texts etc) need to state explicitly.
    2. all fields in this structure are to be output
    3. The structure name is passed to ALV in the parameter I_STRUCTURE_NAME of the function module REUSE_ALV_LIST_DISPLAY.
    All the values entered in the catalog is specific to the particular field whose name is entered in the fieldname FIELDNAME of the fieldcat structure. The name of the table is also entered in the corr. Fieldname TABNAME of the structure.
    The different possible attributes are:
    • Row_pos (row position): Only relevant if the list output is to be multi-line (two or three lines) by default. So, this attribute can be used maintain certain level of alignment in the output.
    Value set: 0, 1 – 3
    • Col_pos (column position): This parameter is relevant when the fields in the output are to be different from the sequence of the fields in the internal table used for display. The parameter specifies the relative column position of the field in the list output. The column order can be changed interactively by the user. If this parameter is initial for all field catalog entries, columns appear in the internal table field sequence.
    Value set: 0, 1 – 60
    • Fieldname (field name): This is the name of the internal table field for which the parameters are passed in the catalog.
    Value set: internal output table field name (required parameter)
    • Tabname (internal output table): Name of the internal output table that contains the field FIELDCAT-FIELDNAME above.
    Value set: SPACE, internal output table name.
    • Ref_fieldname (reference field name): Name of the Data Dictionary field referred to. This parameter is only used when the internal output table field described by the current field catalog entry has a reference to the Data Dictionary (not a program field), and the field name in the internal output table is different from the name of the field in the Data Dictionary. If the field names are identical, naming the Data Dictionary structure or table in the FIELDCAT-REF_TABNAME parameter is sufficient.
    Value set: SPACE, Data Dictionary field name.
    • Ref_tabname (reference table/structure field name): Structure or table name of the referred Data Dictionary field. This parameter is only used when the internal output table field described by the current field catalog entry has a Data Dictionary reference (not a program field).
    Value set: SPACE, name of a Data Dictionary structure or table
    Link to currency unit
    • Cfieldname (currency unit field name): This is used for currency fields that have a reference to any unit field. This is only relevant for amount columns with associated unit. This parameter contains the Name of the internal output table field containing the currency unit associated with the amount field FIELDCAT-FIELDNAME. The field in FIELDCAT-CFIELDNAME must have its own field catalog entry.
    Value set: SPACE, output table field name
    • Ctabname (internal currency unit field output table): Name of the internal output table containing the FIELDCAT-CFIELDNAME field.
    Value set: SPACE, output table field name.
    Link to measurement unit
    • Qfieldname (measurement unit field name): Only relevant for quantity columns with unit link. Name of the internal output table field containing the measurement unit associated with the quantity field FIELDCAT-FIELDNAME. The field in FIELDCAT-QFIELDNAME must have its own field catalog entry.
    Value set: SPACE, output table field name.
    • Qtabname (internal measurement unit field output table): Name of the internal output table containing the FIELDCAT-QFIELDNAME field.
    Value set: SPACE, output table field name.
    • Outputlen (column width): This parameter is used if the desired output length for a field is desired to be different from the internal output table field. For fields with a Data Dictionary link this parameter can be left initial. For fields without a Data Dictionary link (program field) the parameter must be given the value of the desired field list output length (column width).
    Initial = column width is the output length of the referred Data Dictionary field (domain).
    N = column width is n characters.
    Value set: 0 (initial), n.
    • Key (key column): By default, the system makes some fields in the output as key fields, provided the fields are key fields in their referencing table. Using this parameter, fields other than key fields of the referencing table can be made key field. This parameter is most important if the output needs to contain some field which are not scrollable or cannot be hidden.
    If the internal output table contains fields that are key fields from different tables, then all those fields in the report output becomes unscrollable and cannot be hidden. So, the fields in the output internal table should not be referenced from tables in which they are key fields. Instead, they should be referenced to the tables in which they are not key fields, incase they are not desired as key field in the output.
    'X' = key field (key field output in color) and Key fields can not be interactively hidden. Parameter FIELDCAT-NO_OUT must be left initial.
    Value set: SPACE, 'X'.
    • Key_sel (hideable key column): This parameter is only relevant for the fields which are made key fields using FIELDCAT-KEY = 'X'. Using this parameter the Key field can be hidden interactively.
    The key column sequence cannot be changed interactively by the user. The output is controlled by the FIELDCAT-NO_OUT parameter analogously to non-key fields.
    Value set: SPACE, 'X'.
    • No_out (field in field list): This parameter is used to remove certain fields from the output during initial display. The user can however interactively choose the field for output from the field list in the display variant.
    'X' = field is not displayed in the current list.
    Value set: SPACE, 'X'.
    • Tech (technical field): This parameter is used to make certain field display only in the field catalog. The fields with this parameter set cannot be output in the list nor can they be displayed interactively from the catalog.
    'X' = technical field.
    Value set: SPACE, 'X'.
    • Emphasize (highlight columns in color): As name suggests, this field parameter is used to highlight certain field with chosen colors.
    Value set: SPACE, 'X' or 'Cxyz' (x:'1'-'9'; y,z: '0'=off ,'1'=on).
    'X' = column is colored with the default column highlight color.
    'Cxyz' = column is colored with a coded color:
    - C: Color (coding must begin with C)
    - X: color number
    - Y: bold
    - Z: inverse
    • Hotspot (column as hotspot): This parameter is used to make certain field appear as hotspot i.e. a hand is displayed if the cursor is positioned on the field value. Single click on such fields cause the PICK OR F2 events to happen.
    Value set: SPACE, 'X'.
    'X' = column cells are output as hotspots.
    • Fix_column (fix column): This parameter is used to fix certain columns in the output. All columns to be fixed must have this flag, starting from the left. If a column without this flag is output, only the columns to the left of this column are fixed. The user can change the column fixing interactively.
    Value set: SPACE, 'X'.
    'X' = column fixed (does not scroll horizontally).
    • Do_sum (sum over column): the user can also call this function interactively.
    Value set: SPACE, 'X'.
    'X' = a sum is calculated over this internal output table field.
    • No_sum (sums forbidden): No sum can be calculated over this field, although the data type of the field would allow summing.
    Value set: SPACE, 'X'.
    • Icon: The parameter displays certain column contents as icons. The internal output table column contents must be valid icon strings.
    Value set: SPACE, 'X'.
    'X' = column contents to be output as an icon.
    • Symbol: The internal output table column must be a valid symbol character.
    Value set: SPACE, 'X'
    'X' = column contents are to be output as a symbol.
    • Just (justification): This parameter is used for alignment of the contents of the output table. This is only relevant for CHAR or NUMC fields in the output internal table. The justification of the column header always follows the justification of the columns. Independent justification of the column header is not possible.
    Value set: SPACE, 'R', 'L', and ‘C’.
    ' ' = Default justification for this data type
    'R' = right-justified output
    'L' = left-justified output
    'C' = centered output.
    • Lzero (leading zeros): By default ALV outputs NUMC fields right-justified without leading zeros. Using this parameter only the NUMC fields can be displayed with leading zeroes.
    Value set: SPACE, 'X'.
    'X' = output with leading zeros.
    • No_sign (no +/- sign): This parameter is used to suppress the signs of the output fields. It is only relevant for the value fields.
    Value set: SPACE, 'X'.
    'X' = value output without +/ sign.
    • No_zero (suppress zeros): Only relevant for value fields.
    Value set: SPACE, 'X'.
    'X' = suppress zeros.
    • Edit_mask (field formatting): To apply the report output formatting options same as in the WRITE statement in report writing.
    Value set: SPACE, template.
    The following parameters are used for customizing the texts in the heading of the output of the columns. The texts are taken from the Data Dictionary for fields with a Data Dictionary reference. If this is not desired, the text parameters can also be specified. The Data Dictionary texts are then ignored.
    If the user changes the column width interactively, the column header text with the appropriate length is always used.
    The interactive function 'Optimize column width' takes account of both the field contents and the column headers: if all field contents are shorter than the shortest column header, the column width depends on the column header.
    The 'long field label' is also used in display variant definition,
    Sort, etc. Popup.
    • seltext_l (long field label)
    • seltext_m (medium field label)
    • seltext_s (short field label)
    • reptext_ddic(header) Analogous to the Data element main header
    • Ddictxt (specify text) : You can specify with values 'L', 'M', and 'S', the keyword that should always be used as column header. If the column width changes, no attempt is made in this case to find an appropriate header for the new output width.
    Value set: SPACE, 'L', 'M', and ‘S’.
    Sample code:
    Suppose I_PO_DETAILS is an internal table containing two fields EBELN (PO number) and EBELP (PO item no).
    DATA: L_FIELDCAT TYPE SLIS_FIELDCAT_ALV. “Local variable to hold the parameters
    for a particular field of the field catalog
    CLEAR L_FIELDCAT.
    L_FIELDCAT-TABNAME = 'I_PO_DETAILS'.
    L_FIELDCAT-FIELDNAME = 'EBELN'.
    L_FIELDCAT-KEY = 'X'. “The PO no is made the key field,
    “Colored and non scrollable
    L_FIELDCAT-HOTSPOT = 'X'. “The po no becomes a hotspot
    L_FIELDCAT-SELTEXT_S = ‘P.O No’.
    L_FIELDCAT-SELTEXT_M = 'P order No'.
    L_FIELDCAT-SELTEXT_L = 'Purchase order No'.
    APPEND L_FIELDCAT TO I_FIELDTAB.
    CLEAR L_FIELDCAT
    L_FIELDCAT-TABNAME = 'I_PO_DETAILS'.
    L_FIELDCAT-FIELDNAME = 'EBELN'.
    L_FIELDCAT-KEY = 'X'. “The po item no is made the key field,
    “Colored and non scrollable
    L_FIELDCAT-SELTEXT_S = 'Item No'.
    L_FIELDCAT-SELTEXT_M = 'Item No`.
    L_FIELDCAT-SELTEXT_L = 'PO Item No'.
    APPEND L_FIELDCAT TO I_FIELDTAB.
    CLEAR L_FIELDCAT
    Thus the catalog for the report output is prepared.
    Step 4
    The next step is to build an event table, which are used for firing both user commands and the system dependent events i.e. top of page, end of page etc.
    A list of possible events is populated into an event table (I_EVENTS) when this table is passed to the function module REUSE_ALV_EVENT_NAMES_GET. The return table from this function module contains all the possible events.
    The function module contains following import and export parameters.
    IMPORTING PARAMETERS: I_LIST_TYPE
    This parameter has possible values from 0-4.
    The parameter I_LIST_TYPE is of TYPE SLIS_LIST_TYPE and is DEFAULT 0 .
    EXPORTING PARAMETERS: I_EVENTS table.
    This table is of TYPE SLIS_T_EVENT and returns to the program the name of all the possible events.
    The table structure contains the fields:
    I_EVENTS-NAME: Name of the Callback event.
    I_EVENTS-FORM: Name of the form routine that should be called in the calling program at the event.
    Only events with a form routine name are processed.
    The I_EVENTS table returns with the following possible constants:
    1. Slis_ev_item_data_expand TYPE slis_formname VALUE 'ITEM_DATA_EXPAND'.
    Only relevant for hierarchical-sequential lists using the layout parameter IS_LAYOUT-EXPAND_FIELDNAME of the structure IS_LAYOUT. Exit for passing item entries (ITEM table) for a header record that was expanded interactively by the user.
    2. Slis_ev_reprep_sel_modify TYPE slis_formname VALUE 'REPREP_SEL_MODIFY'.
    RS_SELFIELD-TABINDEX contains the header table index for which the item entries are to be put in the global item output table (T_OUTTAB_SLAVE). The Callback is only called if ALV has no items for a header that is to be expanded.
    RFLG_ALL is passed with 'X' if the user shows all items. The application must ensure that entries are not repeated in the item table.
    RS_SELFIELD is initial in this case.
    3. Slis_ev_caller_exit_at_start TYPE slis_formname VALUE 'CALLER_EXIT'.
    Is called at the beginning of the function module to make special settings. It is not usually used.
    4. Slis_ev_user_command TYPE slis_formname VALUE 'USER_COMMAND'.
    As this is a frequently-used Callback event, the form routine can also be passed directly in the interface by passing the user command in the IMPORTING parameter I_CALLBACK_USER_COMMAND.
    5. Slis_ev_top_of_page TYPE slis_formname VALUE 'TOP_OF_PAGE'.
    Equivalent to the list processing TOP-OF-PAGE event.
    6. Slis_ev_top_of_coverpage TYPE slis_formname VALUE 'TOP_OF_COVERPAGE'.
    The selection information and list status are output together (if they exist) on a separate page by default
    7. Slis_ev_end_of_coverpage TYPE slis_formname VALUE 'END_OF_COVERPAGE'.
    Analogously to TOP_OF_COVERPAGE the user can add other information
    to the information output by ALV (selection information, list status) at this event.
    8. Slis_ev_foreign_top_of_page TYPE slis_formname VALUE ‘FOREIGN_TOP_OF_PAGE'.
    The Top-of-page event is always processed in ALV and is only passed to the caller via the Callback mechanism. This is still the case if the caller, e.g. by a user action, processes a branch list which was not formatted by ALV (e.g. a popup with additional information about the list record selected and displayed by ALV).
    In this case, top-of-page cannot be formatted by ALV analogously to the basic list, it must be handled completely by the caller. The event top-of-page still occurs in ALV. When ALV notices a top-of-page which was not caused by an ALV output, the form routine in FOREIGN_TOP_OF_PAGE is called.
    9. Slis_ev_foreign_end_of_page TYPE slis_formname VALUE 'FOREIGN_END_OF_PAGE'.
    The event end-of-page is always processed in ALV and only passed to the caller via callback. This is still the case, e.g. when the caller processes a details list which was not formatted by ALV (e.g. a popup with further information about selected list records which were displayed by ALV).
    In this case, end-of-page cannot be formatted by ALV analogously to the basic list, it must be handled completely by the caller. The event end-of-page still occurs in ALV. When ALV notices an end-of-page that was not caused by an ALV output, the form routine in FOREIGN_END_OF_PAGE is called.
    10. Slis_ev_pf_status_set TYPE slis_formname VALUE 'PF_STATUS_SET'.
    If a user list status is to be set, it must be done in the form routine assigned to this event. The ALV function codes, which must not be active, are in the Parameter RT_EXTAB. This table must be passed with the SET PF-STATUS command (with inactive user function codes as well, if necessary).
    The STANDARD status of the function group SALV should be used as a template for a user-specific status. As this is a frequently used Callback event, its form routine can also be passed directly in the interface in the IMPORTING parameter I_CALLBACK_PF_STATUS_SET.
    11. Slis_ev_list_modify TYPE slis_formname VALUE 'LIST_MODIFY'.
    LIST_MODIFY USING R_TABNAME TYPE SLIS_TABNAME
    R_INDEX LIKE SY-TABIX
    R_INDEX_ITEM LIKE SY-TABIX
    R_INDEX_SUM LIKE SY-TABIX.
    12. Slis_ev_top_of_list TYPE slis_formname VALUE 'TOP_OF_LIST'.
    Information output at the start of the list
    13. Slis_ev_end_of_page TYPE slis_formname VALUE 'END_OF_PAGE'.
    Information output at the end of a page. This is only called for printing.
    14. Slis_ev_end_of_list TYPE slis_formname VALUE 'END_OF_LIST'.
    Information output at the end of the list
    15. Slis_ev_after_line_output TYPE slis_formname VALUE 'AFTER_LINE_OUTPUT'.
    Output information after each output line. Should only be used in justified cases because it costs a lot of performance.
    16. Slis_ev_before_line_output TYPE slis_formname VALUE 'BEFORE_LINE_OUTPUT'.
    Output information before each output line. Should only be used in justified cases because it costs a lot of performance.
    17. Slis_ev_subtotal_text TYPE slis_formname VALUE 'SUBTOTAL_TEXT'.
    This event table (I_EVENTS) is now checked with the desired constants. If the desired constant is found, then the corresponding field for the FORM NAME is populated with the name of the routine containing the corresponding event.
    Sample code :
    FORMNAME_TOP_OF_PAGE TYPE SLIS_FORMNAME VALUE 'TOP_OF_PAGE',
    FORMNAME_END_OF_PAGE TYPE SLIS_FORMNAME VALUE 'END_OF_PAGE', FORMNAME_USER_COMMAND TYPE SLIS_FORMNAME VALUE 'USER_COMMAND'.
    DATA: L_I_EVENT TYPE SLIS_ALV_EVENT.
    CALL FUNCTION 'REUSE_ALV_EVENTS_GET'
    EXPORTING
    I_LIST_TYPE = 0
    IMPORTING
    ET_EVENTS = I_EVENTS.
    READ TABLE I_EVENTS WITH KEY NAME = SLIS_EV_TOP_OF_PAGE
    INTO L_I_EVENT.
    IF SY-SUBRC = 0.
    MOVE FORMNAME_TOP_OF_PAGE TO L_I_EVENT-FORM.
    APPEND L_I_EVENT TO I_EVENTS.
    ENDIF.
    READ TABLE I_EVENTS WITH KEY NAME = SLIS_EV_END_OF_PAGE
    INTO L_I_EVENT.
    IF SY-SUBRC = 0.
    MOVE FORMNAME_END_OF_PAGE TO L_I_EVENT-FORM.
    APPEND L_I_EVENT TO I_EVENTS.
    ENDIF.
    CLEAR L_I_EVENT.
    READ TABLE I_EVENTS WITH KEY NAME = SLIS_EV_USER_COMMAND
    INTO L_I_EVENT.
    IF SY-SUBRC = 0.
    MOVE FORMNAME_USER_COMMAND TO L_I_EVENT-FORM.
    APPEND L_I_EVENT TO I_EVENTS.
    ENDIF.
    This will prepare the events table for the report.
    The report will contain three forms for the above events:
    1. FORM TOP_OF_PAGE : This form will contain the top of page event for the report i.e header etc
    Using the function module ‘REUSE_ALV_COMMENTARY_WRITE’, the internal table containing the headings for top of page event can be passed to the list output. Also, any logo specific to the report can be passed to the function module.
    2. FORM END_OF_PAGE : This form will contain the end of page event for the report i.e footer etc
    3. FORM USER_COMMAND : This form will contain the desired user command i.e pick/line selection
    Step 5
    A layout is build for the report output list description USING the internal table declared above (I_LAYOUT).
    Output list description structure.
    The parameters are described under the following heads:
    • Display options
    • Exceptions
    • Totals
    • Interaction
    • Detail screen
    • Display variants (only for hierarchical-sequential lists)
    • Color
    • Other
    The layout table is of type slis_layout_alv_spec and has the following fields:
    Display options
    1. Colwidth_optimize (1) TYPE c: This parameter optimizes the length of the different columns in the output. The width of the different col. now depends on the max. Length of the data in the column.
    Value set: SPACE, 'X'
    'X' = optimizes the column width so that all contents are displayed completely.
    2. No_colhead(1) TYPE c : This parameter suppresses the column headings
    Value set: SPACE, 'X'.
    'X' = column headers are not output
    3. No_hotspot(1) TYPE c : The heading of the report output are not output as hotspot.
    Value set: SPACE, 'X'.
    'X' = column headers are not output as hotspot
    4. Zebra(1) TYPE c : The report is output in the striped pattern.
    Value set: SPACE, 'X'.
    'X' = striped pattern (e.g. for wide lists)
    5. No_vline(1) TYPE c : The report output contains columns only separated by space and no lines. It is not relevant for: hierarchical-sequential lists and multiple-line lists.
    Value set: SPACE, 'X'.
    'X' = columns separated by SPACE
    6. No_min_linesize(1) TYPE c : The report line size is equal to the width of the list. It is not relevant for block lists.
    Value set: SPACE, 'X’.
    'X' = line size depends on list width
    ' ' = Line size is set to 80 or MIN_LINESIZE (if > 0) .
    7. Min_linesize LIKE sy-linsz: The report output contains a minimum possible length of line. If initial min_linesize is set to 80 by default, then this parameter is used to customize it. The prerequisite for this is that the parameter no_min_linesize should be ' '.
    Value set: 0, 10 - 250
    If the list is wider, the format uses the list width (maximum 250 or MAX_LINESIZE (if > 0)).
    8. Max_linesize LIKE sy-linsz: The default max. Linesize is 250. To change this default value, this parameter can interactively-define the maximum list width setting.
    Value set: 0, 80 - 1020
    9. Window_titlebar LIKE rsmpe-tittext: To set the titlebar on the report output.
    10. No_uline_hs(1) TYPE c.
    Exceptions
    11. Lights_fieldname TYPE slis_fieldname: Internal output table field containing the codes of exceptions to be output.
    Output table field code: '1' = red traffic light
    '2' = yellow traffic light
    '3' = green traffic light Fieldname for exception
    Value set: SPACE, internal output table field name.
    12. Lights_tabname TYPE slis_tabname: Name of the internal output table that contains the field in the parameter LIGHTS_FIELDNAME. If LIGHTS_FIELDNAME is not empty, this field must also be filled for hierarchical-sequential lists. Only relevant for hierarchical-sequential lists.
    . Value set: SPACE, internal output table name.
    13. Lights_rollname LIKE dfies-rollname: The documentation of this data element is displayed when you call F1 help for an exception column.
    Value set: SPACE, data element name.
    14. Lights_condense(1) TYPE c : If a list record is output with 'red traffic light', each
    Subtotal that includes this record is also output with 'red traffic light'.
    Value set: SPACE, 'X'
    'X' = the 'maximum' exception of the items in the subtotal is output at subtotal level.
    Sums
    15. No_sumchoice(1) TYPE c : This parameter allows the choice for summing up
    Only by fieldcatalog.
    Value set: SPACE, 'X'
    'X' = fields which are to be summed, passed by the calling program (FIELDCAT-DO_SUM = 'X'). The user should not be able to change this value interactively.
    16. No_totalline(1) TYPE c : Removes the option of having totals after sub-totals.
    Value set: SPACE, 'X'
    'X' = no total record is to be output. Subtotals can still be calculated and output. The fields in the subtotals are flagged DO_SUM = 'X' in the field list.
    17. No_subchoice(1) TYPE c : Does not allow the user to interactively change the field chosen for subtotals.
    Value set: SPACE, 'X'
    'X' = value whose change triggers subtotals, provided by the calling program. The user should not be able to change this value interactively.
    18. No_subtotals(1) TYPE c : No subtotals possible
    Value set: SPACE, 'X'
    'X' = no subtotals.
    19. Numc_sum(1) TYPE c : Totals only possible for NUMC-Fields.
    20. No_unit_splitting TYPE c: No separate total lines by inh.units
    21.totals_before_items TYPE c: Display totals before the items
    22. Totals_only(1) TYPE c : Show only totals
    Value set: SPACE, 'X'
    'X' = only total records are output.
    23. Totals_text(60) TYPE c : Text for 1st col. in totals
    Value set: SPACE, string (max.60)
    ' ' = The first column in the total record contains an appropriate number of '*'s to indicate the total by default. If the first column is wide enough, the string 'Total' is output after the asterisks.
    'String’ = The string passed is output after the total indicated by '*', if the column is wide enough.
    24. Subtotals_text(60) TYPE c : Texts for subtotals
    Value set: SPACE, string (max.60)
    ' ' = In the first column of subtotal records, the subtotal is indicated by an appropriate number of '*' by default. If the first column is not a subtotal criterion, the string 'Total' is output after the asterisks, if the column is wide enough.
    'String’ = the string passed is output after the subtotal indicated by '*', if the column is wide enough and the first column is not a subtotal criterion. If it is a subtotal criterion, its value is repeated after the total, if the column is wide enough.
    Interaction
    25. Box_fieldname TYPE slis_fieldname: Fieldname for checkbox in the report output. If the list has checkboxes at the start of records (for selecting several records), this parameter contains the internal output table field name indicated by the checkbox selection column. The field is a checkbox at the start of list records without a list header.
    Value set: SPACE, internal output table field name
    26. Box_tabname TYPE slis_tabname: Name of the internal output table that contains the field in the parameter BOX_FIELDNAME. If BOX_FIELDNAME is not empty, this field must also be filled for hierarchical-sequential lists.
    Value set: SPACE, internal output table name.
    27. Box_rollname LIKE dd03p-rollname: rollname for checkbox
    28. Expand_fieldname TYPE slis_fieldname: fieldname flag ‘expand’. The user can show or hide the items by clicking on the folder symbol (hotspot). If the items for a header entry are only to be read by the calling program and passed to ALV when a header has been expanded interactively, this can be controlled via the CALLBACK event 'ITEM_DATA_EXPAND'.
    29. Hotspot_fieldname TYPE slis_fieldname: Used to make the fieldname flag hotspot.
    30. No_input(1) TYPE c : The fields are only display fields.
    Value set: SPACE, 'X'
    'X' = all ready-for-input fields in a list are displayed as not ready-for-input. (Record selection checkboxes and fields which can be made ready-for-input via the field list parameter FIELDCAT-INPUT = 'X')
    31. F2code LIKE sy-ucomm: To assign an ALV standard function code to double-click (F2), assign the function code to this parameter. Ex.: to assign the ALV standard function 'Detail' ('&ETA') to F2.
    => LAYOUT-F2CODE = '&ETA'.
    Value set: SPACE, function code
    32. Confirmation_prompt: confirm. Prompt when leaving
    Value set: SPACE, 'X'
    'X' = if one of the functions ‘Back (F03)', ‘Exit (F15)' or ‘Cancel (F12)' occurs, a confirmation prompt appears.
    33. Key_hotspot(1) TYPE c : The key fields are displayed as hotspot. The columns defined in the field catalog as key fields (FIELDCAT-KEY = 'X') are output as hotspots, i.e. clicking on a key column (highlighted in color in the list) calls the function under F2.
    Value set: SPACE, 'X'.
    34. Reprep(1) TYPE c : report report interface active.
    35. Group_buttons(1) TYPE c : group-buttons for COL1 - COL5 . Group output fields via FIELDCAT-SP_GROUP in the field list, and pass the group name to the list module in the interface parameter IT_SPECIAL_GROUPS.
    Value set: SPACE, 'X'.
    36. No_keyfix(1) TYPE c : Used to make the key fields scrollable.
    Value set: SPACE, 'X'.
    ' ' = The key columns defined in the field catalog by FIELDCAT-KEY = 'X' are fixed in the list output. These columns do not scroll horizontally. The item table key columns are fixed in hierarchical-sequential lists. The header table key fields are not considered here.
    'X' = key columns not fixed
    37. Get_selinfos(1) TYPE c : To read selection screen.
    Value set: SPACE, 'X'.
    If the calling program is a report with an ABAP/4 selection screen, setting this parameter makes ALV read the selection screen again. If the selections are read successfully, a pushbutton, via which the user can call a popup which lists the report selections in a simple form, becomes active on the results list output by ALV.
    38. group_change_edit(1) TYPE c : Settings by user for new group
    Value set: SPACE, 'X'
    'X' = the user can enter a format option for each sort criterion in the sort/subtotal popup, for the list format when this value changes (e.g. new page or underline).
    39. No_scrolling(1) TYPE c : Does not allow scrolling of the list to the right.
    Value set: SPACE, 'X'.
    40. Expand_all(1) TYPE c : Expand all positions
    Detailed screen
    40. Detail_popup(1) TYPE c : show detail in popup.
    Value set: SPACE, 'X'
    ' ' = List record detail display in full-screen mode, with top-of-page.
    'X' = list record detail display in popup (without top-of-page).
    41. Detail_initial_lines(1) TYPE c : show also initial lines
    Value set: SPACE, 'X'
    ' ' = Only fields whose contents are not initial are output in the detail view.
    'X' = initial field contents are also output in detail.
    41. detail_titlebar(30) type c : Titlebar for detail screen
    Value set: SPACE, string (max.30)
    ` ' = ' Detail: Display' is output as the title of the detail window.
    'String’ = the string passed is output as the title of the detail window.
    Display variants
    42. Header_text (20) TYPE c: Text for header button. Only relevant for hierarchical-sequential lists. You can toggle between display field and field list views via pushbuttons in the display variant definition popup for hierarchical-sequential lists. The views refer to the hierarchy level of the fields. This is technically a toggle between the header table and item table fields.
    Value set: SPACE, CHAR (20)
    ' ' = The header table field pushbutton text is 'Header' by default.
    CHAR (20) = header table field pushbutton text.
    43.item_text(20) TYPE c : Text for item button. Only relevant for hierarchical-sequential lists. You can toggle the view between the display fields and the field list via pushbuttons in the display variant definition popup for hierarchical-sequential lists. The views refer to the hierarchy level of the fields. This is technically a toggle between the header table and item table fields.
    Value set: SPACE, CHAR (20)
    ' ' = The pushbutton text for the item table fields is 'Item' by default.
    CHAR (20) = item table field pushbutton text.
    44.default_ item(1) TYPE c : Items as default. Only relevant for hierarchical-sequential lists.
    Value set: SPACE, 'X'
    ' ' = The header table fields are displayed by default in the display variant definition popup. The user can switch to the item table fields interactively.
    'X' = the item table fields are displayed by default in the display variant Definition Popup. The user can switch to the header table fields interactively.
    Colour
    45. Info_fieldname TYPE slis_fieldname: infofield for listoutput. A whole list record can be colored individually using a color code in a column of the internal output table for the record. Assign the name of the field containing the color code to this parameter.
    Value set: SPACE, internal output table field name
    The internal output table field must be of type CHAR(3).
    The code must have the following syntax: 'Cxy':
    C = color (all codes must start with 'C')
    X = color number ('1'-'9')
    Y = bold ('0' = off, '1' = on)
    46. Coltab_fieldname TYPE slis_fieldname: Cells can be colored individually using a color code which is contained in a column of the internal output table for the record containing the cell. Assign the name of the field to this parameter.
    Others
    47. List_append(1) TYPE c : no call screen. It is only useful to output block-lists without specifying the above modules if the number of list blocks exceeds, or may exceed, the maximum number specified in the block module documentation. These operations are not possible for user-defined block lists.
    Example code :
    I_LAYOUT-f2code = ws_fcode.
    I_LAYOUT-zebra = 'X'.
    I_LAYOUT-colwidth_optimize = 'X'.
    I_LAYOUT-no_keyfix = 'X'.
    I_LAYOUT-get_selinfos = 'X'.
    I_LAYOUT-no_hotspot = 'X'.
    I_LAYOUT-no_input = 'X'.
    I_LAYOUT-hotspot_fieldname = FIELDNAME.
    I_LAYOUT-no_input = ‘X’.
    I_LAYOUT-no_vline = `X’.
    I_LAYOUT-no_colhead = ‘ ‘.
    I_LAYOUT-lights_condense = ` `.
    I_LAYOUT-totals_text = ` `.
    I_LAYOUT-subtotals_text = ` `.
    I_LAYOUT-totals_only = ` `.
    I_LAYOUT-key_hotspot = ‘X’.
    I_LAYOUT-detail_popup = ‘X’.
    I_LAYOUT-group_change_edit = ‘X’.
    I_LAYOUT-GROUP_BUTTONS = ‘X’.
    Step 6
    This step is required to get the selection screen information in the report output.
    The prerequisite for this is to set the parameter LAYOUT-GET_SELINFOS of the IMPORTING structure.
    The parameters to be passed in the IS_SEL_HIDE table are:
    o mode: 'R' = only the entries passed in the internal table IS_SEL_HIDE-T_ENTRIES
    Are output in the pop up. Selection info, which the list tool read in the selection screen (when called by a report with a selection screen), is replaced by the values passed.
    'S' = the selection info which the list tool read in the selection screen of the calling report are modified by the entries in the table IS_SEL_HIDE-T_ENTRIES.
    o t_entries: Selection info table
    o t_entries-mode: 'A' = output the selection info for the current table record in the info popup.
    'D' = do not output select option or SELNAME parameter selection info in the popup.
    o t_entries-selname: (only used in t_entries-mode = 'D') : Name of the select option or parameter.
    The following table fields are only used in t_entries-mode = 'A'. They contain the selection information to be added.
    • t_entries-field: DDIC field name of the field for which selection information is to be output.
    • t_entries-table: DDIC table names of t_entries-field.
    • t_entries-stext: Field name in info popup.
    • If t_entries-field and t_entries-table have been entered, this text is taken from DDIC.
    • t_entries-valuf: Selection condition 'from' value (external format)
    • t_entries-valut: Selection condition 'to' value (external format)
    • t_entries-sign0: (I)nclusive (E)xclusive
    • t_entries-option: All values of the select options Option field allowed.
    Step 6
    The Table IT_SORT is populated with the sort criteria for the different fields.
    The caller specifies the sorting and/or subtotaling of the basic list in the internal table IT_SORT.
    This internal table has the following fields:
    o spos : Sort sequence
    o fieldname : Internal output table field name
    o tabname : Only relevant for hierarchical-sequential lists. Name of the internal output table.
    o up : 'X' = sort in ascending order
    o down : 'X' = sort in descending order
    o subtot : 'X' = subtotal at group value change
    o group : '* ' = new page at group value change ,'UL' = underline at group value change
    Step 7
    The final step in the output of the report is the use of two ALV functions modules.
    1. REUSE_ALV_FIELDCATALOG_MERGE
    2. REUSE_ALV_LIST_DISPLAY
    The first function module is used to pass the field catalog to the report output and merge it with the internal output table.
    FUNCTION reuse_alv_fieldcatalog_merge.
    ""Lokale Schnittstelle:
    *” IMPORTING
    *" VALUE(I_PROGRAM_NAME) LIKE SY-REPID OPTIONAL
    *" VALUE(I_INTERNAL_TABNAME) TYPE SLIS_TABNAME OPTIONAL
    *" VALUE(I_STRUCTURE_NAME) LIKE DD02L-TABNAME OPTIONAL
    *" VALUE(I_CLIENT_NEVER_DISPLAY) TYPE SLIS_CHAR_1
    *" DEFAULT 'X'
    *" VALUE(I_INCLNAME) LIKE TRDIR-NAME OPTIONAL
    *" CHANGING
    *" VALUE(CT_FIELDCAT) TYPE SLIS_T_FIELDCAT_ALV
    *" EXCEPTIONS
    *" INCONSISTENT_INTERFACE
    *" PROGRAM_ERROR
    Import parameters
    I_PROGRAM_NAME: Program in which the internal output table is declared and populated
    I_INTERNAL_TABNAME: Internal output table name
    I_STRUCTURE_NAME: Structure name (structure, table, and view)
    I_CLIENT_NEVER_DISPL: Hide client fields default ‘X’
    I_INCLNAME: Data declarations include name
    CHANGING parameter
    CT_FIELDCAT: Field catalog with field descriptions
    The variant based on a program-internal table should only be used for rapid prototyping since the following restrictions apply:
    1. Performance is affected since the code of the table definition must always be read and interpreted at runtime.
    2. Dictionary reference are only considered if the keywords LIKE or INCLUDE STRUCTURE (not TYPE) are used.
    Step 8
    The other function module is used to display the internal output table with the contents
    FUNCTION reuse_alv_list_display.
    ""Lokale Schnittstelle:
    *” IMPORTING
    *" VALUE(I_INTERFACE_CHECK) DEFAULT SPACE
    *" VALUE(I_CALLBACK_PROGRAM) LIKE SY-REPID DEFAULT SPACE
    *" VALUE(I_CALLBACK_PF_STATUS_SET) TYPE SLIS_FORMNAME
    *" DEFAULT SPACE
    *" VALUE(I_CALLBACK_USER_COMMAND) TYPE SLIS_FORMNAME
    *" DEFAULT SPACE
    *" VALUE(I_STRUCTURE_NAME) LIKE DD02L-TABNAME OPTIONAL
    *" VALUE(IS_LAYOUT) TYPE SLIS_LAYOUT_ALV OPTIONAL
    *" VALUE(IT_FIELDCAT) TYPE SLIS_T_FIELDCAT_ALV OPTIONAL
    *" VALUE(IT_EXCLUDING) TYPE SLIS_T_EXTAB OPTIONAL
    *" VALUE(IT_SPECIAL_GROUPS) TYPE SLIS_T_SP_GROUP_ALV
    *" OPTIONAL
    *" VALUE(IT_SORT) TYPE SLIS_T_SORTINFO_ALV OPTIONAL
    *" VALUE(IT_FILTER) TYPE SLIS_T_FILTER_ALV OPTIONAL
    *" VALUE(IS_SEL_HIDE) TYPE SLIS_SEL_HIDE_ALV OPTIONAL
    *" VALUE(I_DEFAULT) DEFAULT 'X'
    " VALUE(I_SAVE) DEFAULT SPACE
    " VALUE(IS_VARIANT) LIKE DISVARIANT
    " STRUCTURE DISVARIANT DEFAULT SPACE
    " VALUE(IT_EVENTS) TYPE SLIS_T_EVENT OPTIONAL
    " VALUE(IT_EVENT_EXIT) TYPE SLIS_T_EVENT_EXIT OPTIONAL
    " VALUE(IS_PRINT) TYPE SLIS_PRINT_ALV OPTIONAL
    " VALUE(IS_REPREP_ID) TYPE SLIS_REPREP_ID OPTIONAL
    " VALUE(I_SCREEN_START_COLUMN) DEFAULT 0
    " VALUE(I_SCREEN_START_LINE) DEFAULT 0
    " VALUE(I_SCREEN_END_COLUMN) DEFAULT 0
    " VALUE(I_SCREEN_END_LINE) DEFAULT 0
    " EXPORTING
    " VALUE(E_EXIT_CAUSED_BY_CALLER)
    " VALUE(ES_EXIT_CAUSED_BY_USER) TYPE SLIS_EXIT_BY_USER
    " TABLES
    " T_OUTTAB
    " EXCEPTIONS
    " PROGRAM_ERROR
    Import parameters
    I_INTERFACE_CHECK: Interface consistency check log output.
    I_CALLBACK_PROGRAM: Name of the calling program
    I_CALLBACK_PF_STATUS_SET: Set EXIT routine to status.
    I_CALLBACK_USER_COMMAND: EXIT routine for command handling
    I_STRUCTURE_NAME: Internal output table structure name
    IS_LAYOUT: List layout specifications
    IT_FIELDCAT: Field catalog with field descriptions
    IT_EXCLUDING: Table of inactive function codes
    IT_SPECIAL_GROUPS: Grouping fields for column selection
    IT_SORT: Sort criteria for first list display
    IT_FILTER: Filter criteria for first list output
    IS_SEL_HIDE : Selection information modification
    I_DEFAULT: Initial variant active/inactive logic
    I_SAVE: Variants can be saved
    IS_VARIANT : Variant information
    IT_EVENTS: Table of events to perform IT_EVENT_EXIT : Standard fcode exit requests table
    IS_PRINT: Print information
    IS_REPREP_ID: Initialization keys for Re/Re interface
    I_SCREEN_START_COLUMN: Coordinates for list in dialog box
    I_SCREEN_START_LINE: Coordinates for list in dialog box
    I_SCREEN_END_COLUMN: Coordinates for list in dialog box
    I_SCREEN_END_LINE: Coordinates for list in dialog box
    IT_EVENT_EXIT: Standard fcode exit requests table
    IS_PRINT: Print information
    IS_REPREP_ID: Initialization keys for Re/Re interface
    I_SCREEN_START_COLUMN: Coordinates for list in dialog box
    I_SCREEN_START_LINE: Coordinates for list in dialog box
    I_SCREEN_END_COLUMN: Coordinates for list in dialog box
    I_SCREEN_END_LINE: Coordinates for list in dialog box
    Export parameters
    E_EXIT_CAUSED_BY_CALLER: Delete list in CALLBACK_USER_COMMAND
    ES_EXIT_CAUSED_BY_USER: How the user left the list Tables
    T_OUTTAB: Table with data to be displayed ---mandatory
    Example Code
    WS_REPNAME = SY-REPID.
    CALL FUNCTION 'REUSE_ALV_FIELDCATALOG_MERGE'
    EXPORTING
    I_PROGRAM_NAME = WS_REPNAME
    I_INTERNAL_TABNAME = Internal output table field name
    I_INCLNAME = WS_REPNAME
    CHANGING
    CT_FIELDCAT = I_FIELDTAB.
    IF SY-SUBRC <> 0.
    WRITE: 'SY-SUBRC: ', SY-SUBRC, 'REUSE_ALV_FIELDCATALOG_MERGE'.
    ENDIF.
    CALL FUNCTION 'REUSE_ALV_LIST_DISPLAY'
    EXPORTING
    I_CALLBACK_PROGRAM = WS_REPNAME
    I_STRUCTURE_NAME = Internal output table field name
    IS_LAYOUT = I_LAYOUT
    IT_FIELDCAT = I_FIELDTAB
    I_DEFAULT = 'A'
    I_SAVE = 'A'
    IS_VARIANT = 'X'
    IT_EVENTS = I_EVENTS[]
    IT_SORT = I_SORT
    IS_SEL_HIDE = I_SELINFO
    TABLES
    T_OUTTAB = Internal output table field name.
    IF SY-SUBRC <> 0.
    WRITE: 'SY-SUBRC: ', SY-SUBRC, 'REUSE_ALV_LIST_DISPLAY'.
    ENDIF
    THIS IS THE POP UP TO ALLOW THE USER TO DYNAMICALLY SELECT THE FIELDS FOR DISPLAY. HE CAN CHOOSE FROM THIS FIELDS ACC. TO REQUIREMENT AND HIDE THE OTHER FIELDS
    Example report output based prior to selection of the field
    THE USER HAS HIDDEN SOME OF THE FIELD FROM THE TOTAL FIELDS TO CUSTOMIZE THE REPORT OUTPUT
    Example report output after hiding some of the fields
    USER CAN CHOOSE A PARTICULAR SET OF FIELD FROM THE OUTPUT AND CAN SAVE IT AS VARIANTS
                                                                                    Using other function module 'REUSE_ALV_GRID_DISPLAY’ can help us get list output in the form of a grid and also attach logos to the report output.
    Sample code
    1 Simple list output:
    REPORT Y_DEMO_ALV NO STANDARD PAGE HEADING.
    Data to be displayed
    DATA: I_SFLIGHT TYPE TABLE OF SFLIGHT.
    Selection
    SELECT * FROM SFLIGHT INTO TABLE I_SFLIGHT.
    Call ABAP List Viewer (ALV)
    CALL FUNCTION 'REUSE_ALV_LIST_DISPLAY'
    EXPORTING
    I_STRUCTURE_NAME = 'SFLIGHT'
    TABLES
    T_OUTTAB = I_SFLIGHT.
    2.Simple grid output:
    REPORT Y_DEMO_ALV_1.
    Data to be displayed
    DATA: I_SFLIGHT TYPE TABLE OF SFLIGHT.
    Selection
    SELECT * FROM SFLIGHT INTO TABLE I_SFLIGHT.
    Call ABAP List Viewer (ALV)
    CALL FUNCTION 'REUSE_ALV_GRID_DISPLAY'
    EXPORTING
    I_STRUCTURE_NAME = 'SFLIGHT'
    TABLES
    T_OUTTAB = I_SFLIGHT.
    3. Demo for 'REUSE_ALV_POPUP_TO_SELECT'
    REPORT y_demo_alv_3.
    TYPE-POOLS: slis.
    DATA: BEGIN OF i_outtab OCCURS 0.
    INCLUDE STRUCTURE sflight.
    DATA: w_chk TYPE c. "For multiple selection
    DATA: END OF i_outtab.
    I_OUTTAB TYPE SFLIGHT OCCURS 0,
    DATA: i_private TYPE slis_data_caller_exit,
    i_selfield TYPE slis_selfield,
    W_exit(1) TYPE c.
    PARAMETERS: p_title TYPE sy-title.
    START-OF-SELECTION.
    SELECT * FROM sflight INTO TABLE i_outtab.
    CALL FUNCTION 'REUSE_ALV_POPUP_TO_SELECT'
    EXPORTING
    i_title = p_title
    i_selection = 'X'
    i_zebra = 'X'
    I_SCREEN_START_COLUMN = 0
    I_SCREEN_START_LINE = 0
    I_SCREEN_END_COLUMN = 0
    I_SCREEN_END_LINE = 0
    i_checkbox_fieldname = 'W_CHK'
    I_LINEMARK_FIELDNAME =
    I_SCROLL_TO_SEL_LINE = 'X'
    i_tabname = 'I_OUTTAB'
    i_structure_name = 'SFLIGHT'
    IT_FIELDCAT =
    IT_EXCLUDING =
    I_CALLBACK_PROGRAM =
    I_CALLBACK_USER_COMMAND =
    IS_PRIVATE = I_PRIVATE
    IMPORTING
    es_selfield = i_selfield
    e_exit = w_exit
    TABLES
    t_outtab = i_outtab
    EXCEPTIONS
    program_error = 1
    OTHERS = 2.
    IF sy-subrc <> 0.
    MESSAGE i000(0k) WITH sy-subrc.
    ENDIF.
    *****the internal table is modified with a cross sign for marking the
    ***rows selected
    LOOP AT i_outtab WHERE w_chk = 'X'.
    WRITE: / i_outtab-carrid, i_outtab-price.
    ENDLOOP.
    4. Demo for ALV output using field catalog and layout:
    REPORT y_demo_alv NO STANDARD PAGE HEADING.
    ALV related data declaration
    TYPE-POOLS: slis.
    DB-Table
    TABLES sflight.
    Includes
    INCLUDE &lt

  • How to dynamic field insert into intenal table?

    hi friends
    this is my urgent requirements .... how to dynamic field insert into internal table if it possible please tell me
    thanks & regards
    pauldharma

    Hi,
    Go through this
    REPORT  yusmm_text1  NO STANDARD PAGE HEADING
                         LINE-SIZE 199.
    T A B L E S
    TABLES: MARA,
            MAKT,
            THEAD.
    GLOBAL TYPE-POOLS
    TYPE-POOLS : SLIS.
       GLOBAL TYPES
    TYPES : BEGIN OF TP_FINAL,
           MATNR TYPE MARA-MATNR,
           BEGRU TYPE MARA-BEGRU,
           MTART TYPE MARA-MTART,
           MAKTX TYPE MAKT-MAKTX,
           SPRAS TYPE MAKT-SPRAS,
           LTXT(2000)  TYPE C ,
           SRNO TYPE N ,
          END OF TP_FINAL.
    TYPES : BEGIN OF TP_T002,
            SPRAS TYPE T002-SPRAS,
            LAISO TYPE T002-LAISO,
            SRNO TYPE N ,
            END OF TP_T002.
    TYPES : BEGIN OF TP_MARA_MAKT,
            MATNR TYPE MARA-MATNR,
            BEGRU TYPE MARA-BEGRU,
            MTART TYPE MARA-MTART,
            SPRAS TYPE MAKT-SPRAS,
            MAKTX TYPE MAKT-MAKTX,
           END OF TP_MARA_MAKT.
    Types: BEGIN OF tp_matnr,
           matnr TYPE mara-matnr,
           END OF tp_matnr.
       GLOBAL ELEMENTARY VARIABLES
    DATA : gv_date TYPE sy-datum.
    DATA : gv_repid TYPE sy-repid.
    DATA : g_var1(10) TYPE C.
    DATA : gv_index TYPE sy-tabix.
    DATA: gv_strg TYPE string,
          gv_strg1(2000) TYPE C.
    DATA : gv_lang TYPE sy-langu.
    DATA : g_v(3) TYPE N .
    DATA : gv_lines(3) TYPE N .
    DATA : gv_var(3) TYPE N .
    DATA : gv_var1(3) TYPE N.
    DATA: gv_str TYPE STRING.
    DATA: gv_str1 TYPE STRING.
    DATA : gv_li TYPE I,
           gv_lit TYPE I,
           gv_lin TYPE I.
    DATA: g_var11(3) TYPE N,
          gv_li1(3) TYPE N,
          g_var2(3) TYPE N.
    DATA : gv_i1 TYPE I.
    DATA : gv_i TYPE I.
    DATA: gl_lenght TYPE I.
       GLOBAL STRUCTURES
    DATA:   T_NEWTABLE TYPE REF TO DATA,
            T_NEWLINE  TYPE REF TO DATA,
            T_FLDCAT1   TYPE SLIS_T_FIELDCAT_ALV,
            T_FLDCAT   TYPE LVC_T_FCAT,
            WA_IT_FLDCAT TYPE LVC_S_FCAT,
            WA_IT_FLDCAT1 TYPE SLIS_FIELDCAT_ALV,
            WA_COLNO(2) TYPE N,
            WA_FLNAME(5) TYPE C,
            L_LT TYPE SLIS_LAYOUT_ALV.
       GLOBAL INTERNAL TABLES (WITH INCLUDE STRUCTURE)
    DATA : IG_MARA_MAKT TYPE STANDARD TABLE OF TP_MARA_MAKT,
           WG_MARA_MAKT TYPE TP_MARA_MAKT.
    DATA : IG_T002 TYPE STANDARD TABLE OF TP_T002,
           WG_T002 TYPE TP_T002.
    DATA : IG_FINAL TYPE STANDARD TABLE OF TP_FINAL,
           WG_FINAL TYPE TP_FINAL.
    data : IG_MATNR TYPE STANDARD TABLE OF TP_MATNR WITH HEADER  LINE,
           WG_MATNR TYPE TP_MATNR.
    DATA:BEGIN OF IG_THEAD OCCURS 0.
            INCLUDE STRUCTURE THEAD .
    DATA: END OF IG_THEAD.
    DATA:BEGIN OF IG_TLINE OCCURS 0.
            INCLUDE STRUCTURE TLINE  .
    DATA:END OF IG_TLINE.
    FIELD-SYMBOLS
    FIELD-SYMBOLS: <T_DYNTABLE> TYPE STANDARD TABLE,"Dynamic internal
                                                            "tablename
                   <FS_DYNTABLE>,  "Field symbol to create work area
                  <FS_FLDVAL> TYPE ANY.   " Field symbol to assign values
    COMPULSORY
    FIELD-SYMBOLS: <FS_DATA> TYPE REF TO DATA,
                   <FS_DATA1> TYPE REF TO DATA,
                   <FS_2>    TYPE STANDARD TABLE,
                   <FS_22>   TYPE STANDARD TABLE,
                   <FS_1>,
                   <FS_11>,
                   <F>,
                   <FA>,
                   <LWA_LINE_WA>,
                   <LWA_LINE_WA1>.
    ------- Create Dyn Table From FC
    DATA: LT_DATA        TYPE   REF TO DATA,
          LT_DATA1        TYPE   REF TO DATA,
          LWA_LINE       TYPE   REF TO  DATA,
          LWA_LINE1       TYPE   REF TO  DATA,
          LI_FIELD_CAT   TYPE   LVC_T_FCAT,
          LWA_FIELD_CAT  TYPE   LVC_S_FCAT.
       PARAMETERS & SELECT-OPTIONS
    SELECTION-SCREEN : BEGIN OF BLOCK B1 WITH FRAME TITLE TEXT-001.
    SELECT-OPTIONS : S_SPRAS FOR MAKT-SPRAS NO INTERVALS  DEFAULT 'EN'
                                                            OBLIGATORY ,
                     S_MATNR FOR MARA-MATNR,
                     S_MTART FOR MARA-MTART.
    PARAMETERS: GP_SIZE TYPE I DEFAULT '200'.
    SELECTION-SCREEN : END OF BLOCK B1.
       INITIALIZATION
    INITIALIZATION.
      gv_repid = sy-repid.
      gv_date = sy-datum.
    AT SELECTION-SCREEN
    AT SELECTION-SCREEN.
      IF GP_SIZE < 0.
       MESSAGE E002(00).
      ENDIF.
      IF GP_SIZE > 50000.
       MESSAGE W130(26) WITH TEXT-004.
        SET CURSOR FIELD 'gp_size'.
      ENDIF.
    START-OF-SELECTION
    START-OF-SELECTION.
      PERFORM FIELDCAT.
      PERFORM LAYOUT.
      PERFORM DATA_FETCH.
      PERFORM READ_DATA_TO_FINAL.
      SORT ig_final BY matnr spras.
      gv_lin = gv_li.
      gv_li = gv_li - 2.
      LOOP AT ig_final INTO wg_final.
        ASSIGN COMPONENT 1 OF STRUCTURE <LWA_LINE_WA1> TO <FA>.
        <FA> = 'Material Number'.
        ASSIGN COMPONENT 2 OF STRUCTURE <LWA_LINE_WA1> TO <FA>.
        <FA> = 'Authorization Group'.
        g_VAR11 = wg_final-srno + 2.
        gv_li1 = gv_li1 + 2.
        MOVE : g_var11 TO gv_i1.
        ASSIGN COMPONENT g_var11 OF STRUCTURE <LWA_LINE_WA1> TO <FA>.
        <FA> = 'MatDesc'.
        g_var2 = g_var11 + gv_lines.
        ASSIGN COMPONENT g_var2 OF STRUCTURE <LWA_LINE_WA1> TO <FA>.
        <FA> = 'BasicData'.
        APPEND <LWA_LINE_WA1> TO <FS_22>.
        EXIT.
       ENDLOOP.
      LOOP AT ig_final INTO wg_final.
        AT NEW matnr.
          gv_index = sy-tabix.
          ASSIGN COMPONENT 1 OF STRUCTURE <LWA_LINE_WA> TO <F>.
          <F> = wg_final-matnr.
          ENDAT.
        AT NEW MATNR.
        GV_INDEX = SY-TABIX.
        ASSIGN COMPONENT 1 OF STRUCTURE <LWA_LINE_WA1> TO <FA>.
        <FA> = wg_final-matnr.
         ENDAT.
        ASSIGN COMPONENT 2 OF STRUCTURE <LWA_LINE_WA> TO <F>.
        <F> = wg_final-begru.
        ASSIGN COMPONENT 2 OF STRUCTURE <LWA_LINE_WA1> TO <FA>.
        <FA> = wg_final-begru.
        gv_var = wg_final-srno + 2.
        gv_li = gv_li + 2.
        MOVE : gv_var TO gv_i.
        ASSIGN COMPONENT gv_var OF STRUCTURE <LWA_LINE_WA> TO <F>.
        <F> = wg_final-maktx.
        ASSIGN COMPONENT gv_var OF STRUCTURE <LWA_LINE_WA1> TO <FA>.
        <FA> = wg_final-maktx.
        gv_var1 = gv_var + gv_lines  .
        ASSIGN COMPONENT gv_var1 OF STRUCTURE <LWA_LINE_WA> TO <F>.
       <F> = wg_final-ltxt.
        ASSIGN COMPONENT gv_var1 OF STRUCTURE <LWA_LINE_WA1> TO <FA>.
        <FA> = wg_final-ltxt.
        AT END OF matnr.
          APPEND <LWA_LINE_WA> TO <FS_2>.
          CLEAR <LWA_LINE_WA>.
        ENDAT.
        AT END OF matnr.
         APPEND <LWA_LINE_WA1> TO <FS_22>.
         CLEAR <LWA_LINE_WA1>.
        ENDAT.
      ENDLOOP.
      PERFORM display..
    *&      Form  data_fetch
          text
    -->  p1        text
    <--  p2        text
    FORM DATA_FETCH .
      SELECT matnr
              from mara up to gp_size rows
             appending corresponding fields of table ig_matnr
             where matnr in s_matnr
             and mtart in s_mtart.
    loop at ig_matnr.
      SELECT  MARA~MATNR
              MARA~BEGRU
              MARA~MTART
              MAKT~SPRAS
              MAKT~MAKTX FROM MARA INNER JOIN MAKT
        ON MARAMATNR = MAKTMATNR
       appending corresponding fields of TABLE ig_mara_makt  UP TO GP_SIZE
    ROWS
        WHERE makt~spras IN s_spras
        AND   mara~matnr IN s_matnr
        AND   mara~mtart IN s_mtart
        AND   mara~matnr EQ ig_matnr-matnr.
        endloop.
      IF sy-subrc = 0.
        SORT ig_mara_makt.
      ENDIF.
    ENDFORM.                    " data_fetch
    *&      Form  read_data_to_final
          text
    -->  p1        text
    <--  p2        text
    FORM READ_DATA_TO_FINAL .
      LOOP AT ig_mara_makt INTO wg_mara_makt .
        wg_final-MATNR = wg_mara_makt-MATNR.
        wg_final-BEGRU = wg_mara_makt-BEGRU.
        wg_final-MTART = wg_mara_makt-MTART.
        wg_final-SPRAS = wg_mara_makt-SPRAS.
        wg_final-MAKTX = wg_mara_makt-MAKTX.
        READ TABLE ig_t002 INTO wg_t002 WITH KEY spras = wg_final-spras.
        IF sy-subrc = 0.
          wg_final-srno = wg_t002-srno.
        ENDIF.
        CLEAR ig_thead[].
        ig_thead-TDOBJECT = 'MATERIAL'.
        ig_thead-TDNAME   = wg_final-matnr.
        ig_thead-TDID     = 'GRUN'.
        ig_thead-TDSPRAS  = wg_final-spras.
        CALL FUNCTION 'TEXT_READ'
          EXPORTING
            I_HEADER   = IG_THEAD
            I_READONLY = 'X'
          IMPORTING
            E_HEADER   = IG_THEAD
          TABLES
            T_LINES    = IG_TLINE[]
          EXCEPTIONS
            NOTFOUND   = 1.
        IF sy-subrc  EQ 0.
          LOOP AT  ig_tline.
            gv_strg = ig_tline-tdline.
            IF gv_strg1 <> ' '.
              CONCATENATE gv_strg1 ';' gv_strg INTO gv_strg1.
            ELSE.
              gv_strg1 = gv_strg.
            ENDIF.
          ENDLOOP.
          wg_final-ltxt = gv_strg1.
          APPEND wg_final TO ig_final.
          CLEAR wg_final.
          gv_strg1 = ' '.
        ELSE.
          APPEND wg_final TO  ig_final.
        ENDIF.
      ENDLOOP.
    ENDFORM.                    " read_data_to_final
    " read_data_to_final
    *&      Form  layout
          text
    -->  p1        text
    <--  p2        text
    FORM LAYOUT .
      CLEAR L_LT.
      L_LT-ZEBRA = 'X'.
      L_LT-COLWIDTH_OPTIMIZE = 'X'.
      L_LT-WINDOW_TITLEBAR = 'MATERIAL DETAILS'.
    ENDFORM.                    " layout
    *&      Form  fieldcat
          text
    -->  p1        text
    <--  p2        text
    FORM FIELDCAT .
      SELECT SPRAS
               LAISO FROM t002 INTO  CORRESPONDING FIELDS OF TABLE ig_t002
          WHERE spras IN s_spras.
      DESCRIBE TABLE ig_t002 LINES gv_lines.
      LOOP AT ig_t002 INTO wg_t002.
        g_v = g_v + 1.
        Wg_t002-srno = g_v.
        MODIFY ig_t002 FROM wg_t002 TRANSPORTING SRNO.
      ENDLOOP.
      LOOP AT ig_t002 INTO wg_t002.
        CLEAR WA_IT_FLDCAT.
        MOVE SY-INDEX TO WA_COLNO.
        CONCATENATE 'MD-' wg_t002-LAISO
                          WA_COLNO
                         INTO WA_FLNAME.
        WA_IT_FLDCAT-FIELDNAME = WA_FLNAME.
        WA_IT_FLDCAT-DATATYPE = 'CHAR'.
        WA_IT_FLDCAT-SELTEXT = WA_FLNAME.
        WA_IT_FLDCAT-INTLEN = 250.
        WA_IT_FLDCAT-TABNAME = '<FS_2>'.
        APPEND WA_IT_FLDCAT TO T_FLDCAT.
        CLEAR wg_t002.
        ENDLOOP.
      LOOP AT ig_t002 INTO wg_t002.
        CLEAR WA_IT_FLDCAT.
        MOVE SY-INDEX TO WA_COLNO.
        CONCATENATE 'BD-' wg_t002-LAISO
                           WA_COLNO
                        INTO WA_FLNAME.
        WA_IT_FLDCAT-FIELDNAME = WA_FLNAME.
        WA_IT_FLDCAT-DATATYPE = 'CHAR'.
        WA_IT_FLDCAT-SELTEXT = WA_FLNAME.
        WA_IT_FLDCAT-INTLEN = 250.
        WA_IT_FLDCAT-TABNAME = '<FS_2>'.
        APPEND WA_IT_FLDCAT TO T_FLDCAT.
        CLEAR wg_t002.
        ENDLOOP.
      MOVE 'MATNR' TO WA_FLNAME.
      WA_IT_FLDCAT-FIELDNAME = WA_FLNAME.
      WA_IT_FLDCAT-DATATYPE = 'CHAR'.
      WA_IT_FLDCAT-SELTEXT = 'Material No'.
      WA_IT_FLDCAT-INTLEN = 18.
      WA_IT_FLDCAT-TABNAME = '<FS_2>'.
      INSERT WA_IT_FLDCAT INTO T_FLDCAT INDEX 1.
      MOVE 'BEGRU' TO WA_FLNAME.
      WA_IT_FLDCAT-FIELDNAME = WA_FLNAME.
      WA_IT_FLDCAT-DATATYPE = 'CHAR'.
      WA_IT_FLDCAT-SELTEXT = 'Authorization Group'.
      WA_IT_FLDCAT-INTLEN = 4.
      WA_IT_FLDCAT-TABNAME = '<FS_2>'.
      INSERT WA_IT_FLDCAT INTO T_FLDCAT INDEX 2.
      DESCRIBE TABLE T_FLDCAT LINES gv_li.
      ASSIGN LT_DATA TO <FS_DATA>.
    Creating the Dynamic Internal Table
      CALL METHOD CL_ALV_TABLE_CREATE=>CREATE_DYNAMIC_TABLE
        EXPORTING
          IT_FIELDCATALOG           = T_FLDCAT         " Fieldcatalogue
        IMPORTING
          EP_TABLE                  = <FS_DATA>   " Dynamic Internal Table
        EXCEPTIONS
          GENERATE_SUBPOOL_DIR_FULL = 1
          OTHERS                    = 2.
    Assign Dyn Table To Field Sumbol
      ASSIGN <FS_DATA>->* TO <FS_1>.
    Assigning the Internal Table TYPE ANY to Standard internal Table
      ASSIGN <FS_1> TO <FS_2>.
    Creating a Workarea
      CREATE DATA LWA_LINE LIKE LINE OF <FS_2> .
    Assigning the Content to the workares as a Pointer
      ASSIGN LWA_LINE->* TO <LWA_LINE_WA>.
      LOOP AT T_FLDCAT INTO WA_IT_FLDCAT.
        WA_IT_FLDCAT1-FIELDNAME = WA_IT_FLDCAT-FIELDNAME.
        WA_IT_FLDCAT1-TABNAME =  WA_IT_FLDCAT-TABNAME.
        WA_IT_FLDCAT1-SELTEXT_L = WA_IT_FLDCAT-SELTEXT.
       WA_IT_FLDCAT1-REF_TABNAME = 'MARC'.
        APPEND WA_IT_FLDCAT1 TO T_FLDCAT1.
        CLEAR : WA_IT_FLDCAT,WA_IT_FLDCAT1.
      ENDLOOP.
      ASSIGN LT_DATA1 TO <FS_DATA1>.
      CALL METHOD CL_ALV_TABLE_CREATE=>CREATE_DYNAMIC_TABLE
        EXPORTING
          IT_FIELDCATALOG           = T_FLDCAT         " Fieldcatalogue
        IMPORTING
          EP_TABLE                  = <FS_DATA1>  " Dynamic Internal table
        EXCEPTIONS
          GENERATE_SUBPOOL_DIR_FULL = 1
          OTHERS                    = 2.
    Assign Dyn Table To Field Sumbol
      ASSIGN <FS_DATA1>->* TO <FS_11>.
    Assigning the Internal Table TYPE ANY to Standard internal Table
      ASSIGN <FS_11> TO <FS_22>.
    Creating a Workarea
      CREATE DATA LWA_LINE1 LIKE LINE OF <FS_22> .
    Assigning the Content to the workares as a Pointer
      ASSIGN LWA_LINE1->* TO <LWA_LINE_WA1>.
    ENDFORM.                    " fieldcat
    *&      Form  show
          text
    -->  p1        text
    <--  p2        text
    FORM Display .
      CALL FUNCTION 'REUSE_ALV_GRID_DISPLAY'
       EXPORTING
       I_INTERFACE_CHECK                 = ' '
       I_BYPASSING_BUFFER                = ' '
       I_BUFFER_ACTIVE                   = ' '
         I_CALLBACK_PROGRAM                = GV_REPID
        I_CALLBACK_PF_STATUS_SET          = 'PF_STATUS_SET'
        I_CALLBACK_USER_COMMAND           = 'USER_COMMAND'
       I_CALLBACK_TOP_OF_PAGE            = ' '
       I_CALLBACK_HTML_TOP_OF_PAGE       = ' '
       I_CALLBACK_HTML_END_OF_LIST       = ' '
       I_STRUCTURE_NAME                  =
       I_BACKGROUND_ID                   = ' '
       I_GRID_TITLE                      =
       I_GRID_SETTINGS                   =
        IS_LAYOUT                         = L_LT
         IT_FIELDCAT                       = T_FLDCAT1[]
       IT_EXCLUDING                      =
       IT_SPECIAL_GROUPS                 =
       IT_SORT                           =
       IT_FILTER                         =
       IS_SEL_HIDE                       =
       I_DEFAULT                         = 'X'
       I_SAVE                            = ' '
       IS_VARIANT                        =
       IT_EVENTS                         =
       IT_EVENT_EXIT                     =
       IS_PRINT                          =
       IS_REPREP_ID                      =
       I_SCREEN_START_COLUMN             = 0
       I_SCREEN_START_LINE               = 0
       I_SCREEN_END_COLUMN               = 0
       I_SCREEN_END_LINE                 = 0
       I_HTML_HEIGHT_TOP                 = 0
       I_HTML_HEIGHT_END                 = 0
       IT_ALV_GRAPHICS                   =
       IT_HYPERLINK                      =
       IT_ADD_FIELDCAT                   =
       IT_EXCEPT_QINFO                   =
       IR_SALV_FULLSCREEN_ADAPTER        =
    IMPORTING
       E_EXIT_CAUSED_BY_CALLER           =
       ES_EXIT_CAUSED_BY_USER            =
        TABLES
          T_OUTTAB                          = <FS_2>
    EXCEPTIONS
       PROGRAM_ERROR                     = 1
       OTHERS                            = 2
      IF SY-SUBRC <> 0.
    MESSAGE ID SY-MSGID TYPE SY-MSGTY NUMBER SY-MSGNO
            WITH SY-MSGV1 SY-MSGV2 SY-MSGV3 SY-MSGV4.
      ENDIF.
    ENDFORM.                    " display
    FORM PF_STATUS_SET USING RS_EXTAB TYPE SLIS_T_EXTAB.
      SET PF-STATUS 'DISPLAY' .
    ENDFORM. "PF_STATUS_SET
    *& Form Name: user_command *
    *& Form Desc: For Handling USER_COMMAND *
    FORM USER_COMMAND USING IF_UCOMM TYPE SY-UCOMM
                         IS_SELFIELD TYPE SLIS_SELFIELD.
      CASE IF_UCOMM.
        WHEN 'DOWNLOAD'.
          CALL FUNCTION 'POPUP_TO_CONFIRM'
            EXPORTING
      TITLEBAR                    = ' '
      DIAGNOSE_OBJECT             = ' '
              TEXT_QUESTION               = 'Data download to excel'
      TEXT_BUTTON_1               = 'Ja'(001)
      ICON_BUTTON_1               = ' '
      TEXT_BUTTON_2               = 'Nein'(002)
      ICON_BUTTON_2               = ' '
      DEFAULT_BUTTON              = '1'
      DISPLAY_CANCEL_BUTTON       = 'X'
      USERDEFINED_F1_HELP         = ' '
      START_COLUMN                = 25
      START_ROW                   = 6
      POPUP_TYPE                  =
    IMPORTING
      ANSWER                      =
    TABLES
      PARAMETER                   =
    EXCEPTIONS
      TEXT_NOT_FOUND              = 1
      OTHERS                      = 2
          IF SY-SUBRC <> 0.
    MESSAGE ID SY-MSGID TYPE SY-MSGTY NUMBER SY-MSGNO
            WITH SY-MSGV1 SY-MSGV2 SY-MSGV3 SY-MSGV4.
          ENDIF.
          CALL FUNCTION 'GUI_DOWNLOAD'
            EXPORTING
        BIN_FILESIZE                  =
              FILENAME                     = 'C:\Material-Text.xls'
             FILETYPE                      = 'ASC'
        APPEND                        = ' '
         WRITE_FIELD_SEPARATOR         = 'X'
        HEADER                        = '00'
         TRUNC_TRAILING_BLANKS         = 'X'
        WRITE_LF                      = 'X'
        COL_SELECT                    = ' '
        COL_SELECT_MASK               = ' '
         DAT_MODE                      = 'X'
       IMPORTING
         FILELENGTH                    = GL_LENGHT
            TABLES
              DATA_TAB                      = <FS_22>
      EXCEPTIONS
        FILE_WRITE_ERROR              = 1
        NO_BATCH                      = 2
        GUI_REFUSE_FILETRANSFER       = 3
        INVALID_TYPE                  = 4
        NO_AUTHORITY                  = 5
        UNKNOWN_ERROR                 = 6
        HEADER_NOT_ALLOWED            = 7
        SEPARATOR_NOT_ALLOWED         = 8
        FILESIZE_NOT_ALLOWED          = 9
        HEADER_TOO_LONG               = 10
        DP_ERROR_CREATE               = 11
        DP_ERROR_SEND                 = 12
        DP_ERROR_WRITE                = 13
        UNKNOWN_DP_ERROR              = 14
        ACCESS_DENIED                 = 15
        DP_OUT_OF_MEMORY              = 16
        DISK_FULL                     = 17
        DP_TIMEOUT                    = 18
        FILE_NOT_FOUND                = 19
        DATAPROVIDER_EXCEPTION        = 20
        CONTROL_FLUSH_ERROR           = 21
        OTHERS                        = 22
          IF SY-SUBRC <> 0.
    MESSAGE ID SY-MSGID TYPE SY-MSGTY NUMBER SY-MSGNO
            WITH SY-MSGV1 SY-MSGV2 SY-MSGV3 SY-MSGV4.
          ENDIF.
          IF GL_LENGHT NE 0.
            MESSAGE S398(00) WITH 'DATA downloaded to EXCEL'.
          ENDIF.
    Thanks
      ENDCASE.
    ENDFORM.                    "user_command

  • Dynamic field values fromstructure

    Hi amit,
    RMPROG01 is a standard report.i have modified it in such a way that materials can also be restricted by material group entered by the selection screen.for that I created extra select-potion for material group in selection screen and kept an option to provide the excel file name in the selection screen.
    Now the requirement is like that there would be a push button in the selection screen.By pressing it the output report(containing matnr, werks, matkl, last changes ROP, SS, current ROP,SS, dynamic values of ROP SS, ) will be downloaded into excel file entered in the selection screen .
    user will not press the execute button to get the output .
    i have the changenr to get most last changed ROP SS for selected material.
    based on that selected materials and changenr i need the dynamic field values.
    I have made the required changes to get the output in excel sheet by pressing the pushbutton, only those dynamic fields are not coming.
    pls reply if you have any solution or u need any clarification.
    thanks
    PRR

    Hi PRR,
    SELECTION SCREEN PUSHBUTTON [/]<pos(len)> <push>
                                USER-COMMAND <ucom> [MODIF ID <key>].
    i hope this will help you.
    please do reply,
    Thanks and Regards,
    swapnil

Maybe you are looking for

  • EDI - INVOIC01 - E1EDP02 - QUALF 021

    Hello, We are using EDI, message INVOIC01, to create FI vendor invoices automatically, based on SD Invoices. Everything works OK except the fact that I can't use transaction OBCC to select different Cost centers based on ID account assignment. It alw

  • Second language option on opening page

    (Using iWeb 3.0.3) What I would like to arrange: 1) The initial opening page appears in Japanese text, with 2) an 'English' button displayed. When that button is clicked on, 3) an identical opening page appears, with the same features, only in Englis

  • MY LAYER STYLES AND PHOTO EFFECTS ARE NOT SHOWING UP WHE I CLICK THE BOX, NO DROP SHADOW, ETC

    MY LAYER STYLES AND PHOTO EFFECTS ARE NOT SHOWING UP WHE I CLICK THE BOX, NO DROP SHADOW, ETC, I ALSO GET AN ERROR WHEN I OPEN THE EDITOR ONTITLECREATEWITHPARONS COULD NOT BE LOCATED IN THE DYNAMIC LINK ONCORE2DLL

  • Adobe Photoshop Album Starter - Unlock Code

    Hello, I have the Adobe Photoshop Album Starter Edition 3.1. I´ve made the registration but i don´t receive the unlock code to continue using the program. All my photos are closed there. Can you help me, please? Thank you

  • Apple id changed email but my old email coming up on log ons