Sending float to arduino uno using VISA

Hi guys,
Basically i am trying to send a float to arduino uno.
I use for that a string .I send at first its length  then i send the numbers.
For the arduino side ,here is the code.I can see that the board Rx/tx leds blinks when i start the Vi.Unfortunately, the led which  doesn"t blink as it should be.
Here is a quick look at my arduino code.
void setup() {
//Initialize serial and wait for port to open:
Serial.begin(9600);
pinMode(13,OUTPUT);
// Serial.flush();
// prints title with ending line break
int i=0;
int j=0;
int longu=0;
char data='F';
String data2="";
float val=0;
int posVir=0;
void loop()
if (i==0)
delay(10);
data=Serial.read();
longu=(int)data;
while (j<longu+1)
{data=Serial.read();
data2=data2+data;
delay(10);
j=j+1;
val=data2.toFloat();
i=1;
delay(50);
if (val==22.5)
digitalWrite(13,HIGH);
delay(1000);
digitalWrite(13,LOW);
delay(1000);
if (val==315)
digitalWrite(13,HIGH);
delay(4000);
digitalWrite(13,LOW);
delay(4000);
val=0;
Attachments:
Sending data toarduino V2.vi ‏18 KB

Basically a rehash of http://forums.ni.com/t5/LabVIEW/Synchronisation-with-arduino-and-Labview-using-visa/m-p/3110008

Similar Messages

  • Sending a floating point through serial using VISA

    how do I send a floating point number through a serial port to my microcontroller using VISA Write

    I would recommend the Flatten To String because of being able to change the endiness.  Some systems want Big Endian while others want Little Endian.  It is best to specify.
    There are only two ways to tell somebody thanks: Kudos and Marked Solutions
    Unofficial Forum Rules and Guidelines

  • Get error 66, when try to use TCP vi send string to arduino

    I use TCP vi to send string to arduinos (arduino uno+ arduino wifi shield, and they have arduino code preloaded inside ) wirelessly through the router. Sometimes they can communicate well, the arduino receive the string send by the TCP vi. But sometimes, there will be an error 66 come out of TCP Write vi, so, labview loop will stop. Arduino will say "connection failed". And I have config the VI sever allow the arduino to access.
    Another thing I want to mention is, when I highlight the execution, the error will come out more frequently.

    Actually, they can communicate not only once, sometimes the VI can pass data several rounds, but suddenly the error 66 appears in TCP write, the loop will stop. And if I rerun the program, things happens again. can anybody tell me why the error come out? Thanks

  • I can't send anything over 1024 bytes by using visa via TCPIP

    I am trying to use NI-VISA talk to instruments visa TCPIP. The problem is I can not send anything over 1024 bytes using viPrintf or viBufWrite call. A time out will be returned. I tried to use MAX to open a VISA session for my TCPIP device. If I put a string less than 1024 bytes in write buffer, it is fine. Anything longer than that will cause time out and some time the whole MAX crash.

    Hi Johnma,
    I suggest you check the specs on TCP/IP. I seem to remember a limit on the packet size. TCP is just the transport layer. Higher layers should handle the work of breaking packets into smaller sizes and tracking packet sequencing.
    I am relying on memory hear so please verify. (maybe the limit was 4096 and I am full of it).
    I also believe there was some discusion of a related topic recently on info-labview where Rolf did a good job explaining what was happening.
    Search for "Rolf" and "TCP" on Brian Renkins search engine.
    http://infolv.brianrenken.com/
    Ben
    Ben Rayner
    I am currently active on.. MainStream Preppers
    Rayner's Ridge is under construction

  • Communication problem with Arduino UNO R3

    Hello,
    I'm using Labview 2011 to automate a part of the line used to sample's preparation linked to a mass spectrometer. I'm using an Arduino UNO R3 which is linked to valves and I'm supposed to talk to it via numerical signal in order to open or close valves. 
    This Arduinbo is linked to computer via an extension USB cord (almost 10m) and is detected as a COM Port.
    Communication works well when I've just rebooted computer, but when some time have passed the communication seems to degrade and the following errors appear :
    - "Ressource is valid but VISA cannot access to it" when the port COM isn't detected anymore neither by Labview nor by Arduino software wheras Windows can detect it. As advised at this adress (http://digital.ni.com/public.nsf/allkb/936298454061FE5886256C2A0060B321) I executed the first test (desabling of COM port) but not the second one as there is no more Hyperterminal on Windows 7. I dowloaded the equivalent software called Hyperterminal private edition but I don't know the computer control sentences to use to verify if the dialog is of good quality. 
    - Error 5002 also appear, but I verified all the possible reasons enumerated at this address and it cannot be that : http://digital.ni.com/public.nsf/allkb/15AE7F234C5B966886257884006DF1CD
    These bugs appears randomly, this can be just after first launch of .vi or two hours later. 
    Can it be a degradation of numerical signal?
    I put in attachment of the email, reports that were send to me during some of these bugs. 
    Thanks a lot.
    Attachments:
    420dc8d6-e465-4d52-970e-f5c95118fd04.zip ‏74 KB
    452c6aea-2264-4d7e-8554-7095a72ec168.zip ‏36 KB

    Without repeater the USB cable is specified only up to 5m.
    Have run a test with a short cable?
    Greetings from Germany
    Henrik
    LV since v3.1
    “ground” is a convenient fantasy
    '˙˙˙˙uıɐƃɐ lɐıp puɐ °06 ǝuoɥd ɹnoʎ uɹnʇ ǝsɐǝld 'ʎɹɐuıƃɐɯı sı pǝlɐıp ǝʌɐɥ noʎ ɹǝqɯnu ǝɥʇ'

  • How do I use VISA to perform GET (Group Execute Trigger) to three DMMs?

    Hi,
    My systems have about 4 GPIB instruments connecting to my computer via Agilent GPIB-USB Interface card.  I have to use VISA to communicate with the interface and instrument.  I wish I can use NI488,.2 but it does not seem to work with Agilent card.  In NI488.2, I could easily send a command such as X? (to read value from Agilent 3458A) to 3 DMMS at once using sendlist module.  However, I do not know how to do similar parallel poll in VISA.  Can anyone help?  There are three FLUKE8505A on the system.  My goal is to read the three measured values triggered  simultaneously on these three FLUKE DMMs. 
    Sincerely yours,
    Rose

    Hi Rose,
    The How Do I See My Agilent 82357A GPIB-USB Interface in MAX/LabVIEW? knowledgebase article explains how to use an Agilent USB-GPIB with NI-VISA. Using the NI-VISA driver will require you install the Agilent I/O Libraries 14.0 and uninstall the Agilent VISA driver.  Once you get your Agilent GPIB-USB device recognized in MAX, you should be able to control the instruments using LabVIEW. 
    Regards,
    Andy L.
    Applications Engineer
    National Instruments

  • The Java plugin has created a time unfriendly issue with my e-mail account, I can not open or send any e-mail without using this plugin, how can I eliminate this problem without dropping m. firefox?

    A few days ago I tried to e-mail a friend, when I started A box came up and it required me to add a plugin..Java. I contacted my e-mail courier and microsoft, they told me that is was a plugin from Mozilla Firefox. Since then I must go through Java to send or open an e-mail... this is NOT to my satisfaction, it takes too long for all of this to open and if it is not cleared , I am dropping Mozilla and going elsewhere. Why has this occurred? Is this a result of the last update? If so can I delete the last update and continue on the other version?
    == This happened ==
    Every time Firefox opened
    == last week

    Sorry, I have no idea what you mean by '''"The Java plugin has created a time unfriendly issue with my e-mail account, I can not open or send any e-mail without using this plugin,"'''.
    If you think your problem is caused by the Java plugin, you should visit the Java support forum for assistance.
    http://forum.java.sun.com/index.jspa
    If you could explain what you mean by '''"time unfriendly''' issue with my e-mail account", maybe we'll be able to help you solve that issue.
    It might be helpful for us if we knew exactly which web-mail provider you are using. It seems strange to me that viewing or sending web-mail would actually "need" Java for operation, its more likely that some other item on the web page needs Java to run some advertising or other garbage that isn't a necessary part of the web-mail functionality you want to use.

  • How to install LVIFA_BASE in ARDUINO UNO.

    I am using arduino uno with LABVIEW 2012 EVALUATION VERSION. I had installed LIFA in my win7. I want to control servo motor using LABVIEW .
    I had put the sketch of LVIFA_BASE.pde on arduino software. Then i uploaded LVIFA_BASE on arduino.
    I open the code for controllingservo in labview. and run. It shows ERROR 5002.
    please tell me how to use LVIFA_BASE and control servo and d.c. motors from LABVIEW using arduino.
    arduino>>>file>>> open>>> LVIFA_BASE_2.1.1.69>>> LVIFA_BASE.pde>>> ?????????
    what to do next. and how to control using LABVIEW

    Looks like he's opted to continue this one Gerd. I'll put a duplicate notification on the second thread.
    Chakslord: The latest version of LIFA is 2.2.0 which was updated 31 Aug 2012 to include support for LabVIEW 2012 - are you sure that you are using this latest version? (probably not, looking at the changelog on your screenshot). Update your LIFA version and hopefully this will solve the issue you are seeing.
    An easy way to keep up to date with new versions is to use VIPM.
    -CC
    "If anyone needs me, I'll be in the Angry Dome!"

  • How to enable 2 or more analog input pin in arduino uno labview simultaneo​usly for voltage analysis?

    Hi everyone,
    i am new to labview and using arduino uno board for measuring microwave analysis in my project. i want to measure the refflection coefficient by dividing two analog input received to arduino (Vref and Vin) to obtain so. problems come where i just can analyze only one analog input pin only. please, kindly helped to figure it out.i've try the others solution where i create two while loops for different analog pin. u can refer to my circuit in the attachment below.i really2 appreciate ur help, thank you.=)
    Attachments:
    reflection coefficient and Vswr.vi ‏665 KB
    front panel.PNG ‏66 KB
    block diagram.PNG ‏40 KB

    Try this if you have a POT around hook it up to the arduino than use the AnalogInSerial.pde and  load it to your arduino exit out of the arduino platform and  than try my VI see if this helps you.
    Harold Timmis
    [email protected]
    Orlando,Fl
    *Kudos always welcome
    Attachments:
    TalkToArduino.vi ‏28 KB

  • Hey.. m frm india.. m jus advicing apple dat if dey give apple users to buy apps frm deir balance(money will b deducted..) rather by using visa, credit card n all...! its good if apple does dis.. its one kind of problem in india for apple users! i thnk

    m frm india... m jus advicing apple dat y not dey give apple users to buy apps wid d us of their balance( money will b deducted frm their balance) rather by using visa, credits cards n all..... its one kind of problem in india for apple users..I THINK...!!

    Nobody from Apple reads these forum, this a user forum. 
    Send your suggestion here http://www.apple.com/feedback/

  • Send file to serial port using comfromfile

    Hi,
    I am current working on a project with requires to transfer a bin file to the controller, if the file is valid i will get the correct respose.
    if we send a file in hyperterminal using send text file option i am getting response from the controlller as file valid.
    I want to send a file through the code i used comfromfile function i am getting invalid file reponse from the controller even i tried byte by byte with comwrtbyte also i received the same invalid response..
    I cross checked the rs232 configuraiton of both hyperterimal and my code..both are same..even i checked with port sniffer tool to capture the port data..both are same.
    I am not able to find what is the issues with my code. what is the differece in the Hypertemail and CVI functions..
    Regards
    Vikram Kumar P

    Thank you for your support....
    As per policy i cant share my complete code..
    whatever eariler shared code is a part of my application code where the binary data is transfered..there is no issues with formating reading coping.
    I checked the serial data variable before sending the data is correct what expected to send.
    I tried all the serial functions comwrtbyte, comfromfile, comwrt & visa functions..the same behavior is received
    please find the attachment of catured data from portman tool.
    attached 3 files
    hyperterminal captured data - I am getting valid response from controller
    cvi exe captured data - I am getting failed response from controller.
    binary data - downloadable binary file to a flash memory using the RS 232 communication system
    Attachments:
    With CVI applicatoin exe.LOG ‏44 KB
    With hyperterminal.LOG ‏44 KB
    Binary data to transfer.txt ‏1 KB

  • Mac does not show UBS as a serial port option for Arduino Uno

    Hi,
    My Macbook Air with Mavericks will not show a USB connection to Arduino Uno Rev 3. I have tried installing the drivers from: http://www.ftdichip.com/Drivers/VCP.htm but still no luck. Any suggestions appreciated.
    Regards,
    Alex

    I'm running Yosemite on a Late 2011 MacBook Pro...
    I've used Arduino IDE 1.0.5 and have recently upgraded to Arduino IDE 1.6.1
    I've never had to install special USB drivers.
    I simply connect the Arduino UNO R3 to the USB port.
    In Terminal, perform the following command
    ls -al /dev/tty.usb*
    This command will list the USB port for the Arduino, e.g. /dev/tty.usbmodemfa131
    Sure enough, this device appears under Arduino -> Tools -> Port
    Make sure the Arduino is connected to the USB port.

  • Using PXIe-6672 to send trigger to PXI-6682H using NI sample code

    I have a PXI-6682H and a PXIe-6672 card in a PXIe 1075 chassis.  I have an IRIG-B timesource going into the PF1-0 IRIG B connector on the 6682H.  I'm trying to use the 6672 card to route a trigger to the 6682H card to receive an IRIG-B signal and supply a timestamp.  I'm using the example code Time Stamp Trigger.vi (to set the 6682H to receive a trigger via PXI_Trig7 for 6682H PXI slot) and Route Software Trigger.vi (to set device in slot corresponding to the 6672 to PXI_Trig7).  I receive no timestamp.  What gives?  Any help would be appreciated.

    Hello jwins,
    The PXIe-1075 is a multi-segment chassis and the PXI trigger bus is split between each segment.  The figure in page 17 of the PXIe-1075 user manual (http://www.ni.com/pdf/manuals/372537b.pdf) shows this.
    Can you retrieve a time stamp by sending a trigger to the 6682H from a device on the same segment?  If so, you may need to route the trigger bus between segments.
    Follow the steps in the knowledge base article titled Routing PXI Trigger Lines Across the Buses of Multisegment PXI Chassis to route the PXI trigger bus to the segment that contains the 6682H card from MAX. 
    You can also use VISA in your program to Programmatically Route PXI Trigger Lines Across a Multi Segment PXI Chassis.
    Anthony F.
    Product Marketing Engineer
    National Instruments

  • Help with RS232 Communication without using VISA

    I'm a newcomer to LabVIEW, and am currently trying to interface with an instrument that communicates via an RS232 serial port.  This instrument is not compatible with the VISA tool, and since that (and the DAQ Assistant) is all I've used to interface with instruments, I'm at a loss as to where to head next.  I know the baud rate, data format, stop bit and parity bit, and am able to generate the ASCII commands that I want to send to the instrument; I just need a bit of help on knowing which function I can use to go the rest of the way.  Thanks for any help.

    Why is the "instrument is not compatible with the VISA tool"?
    VISA is a device driver interface that allows LabVIEW and other NI programs to communicate with the serial port on the PC.  It doesn't care about what instrument is on the other end of that serial connection.  Likewise, the instrument on the other end should have no idea whether it is being communicated to it by way of VISA, or any other device driver.
    If you are having problems, then it is probably in the way you are using VISA and not within VISA itself.  There may be some other ways that you could have your LabVIEW program access your PC's serial ports without VISA, but you are going to have more headaches and problems that way.
    Please provide more details on the problems you are having with using VISA.

  • Symbol output using VISA but it suppose to be normal string

    i used VISA to retrieve data from device(TADATAKER). when i unload the historical data to my computer. The data come out all symbols and i am sure that the data is in normal string format because i can receive it correctly in using VB.How to solve it?Is it the computer speed will affect the VISA or the VISA time out problem to receive data?I also not really understand the time out function. If within the time out the VISA also cant receive data it will gv a error message.How do i know when the device will return data to computer.why it can not stand there and keep going receive data without gv error.What is the best time out number or how to determine it?

    please post the exact VISA query you are using.
    As far as the timeout, I rarely change the value. I usually set it to 2 seconds and leave it alone unless I have a very long operation coming up. There is one particular setting a have to use on my power meter to measure a very low duty cycle noise waveform. The power meter can take up to 45 seconds to settle and return data. So before I send the query command I set the timeout to 45000mS. I believe you can set it to a very very large value. Check the VISA manual. ]
    The purpose for the timeout function is so that if you make a query and the instrument is not connected to the bus, or has an internal problem, or there is some other failure, your program doesn't have to just lock up. The query will fail with
    a timeout and your code can use the error information to notify the operator of the problem. So set it to some reasonable value and change it when you start a long operation.
    You mention using VB, but it is unclear if you are still using it. What are you programming with now? That may also be helpful to solving your problem.

Maybe you are looking for