Simple "OpenFile" in CVI

Anyone Everyone, I could sure use some help. My CVI code won't do a simple. I have used the "FileSelectPopup" function to obtain the  "pathName" that it out puts and am using that in the "OpenFile"
function to open the file. This is all being take care of in a callback function after a button is pushed. Can someone explain to me why this simple act is not resulting in the display of the selected file? I
could really use the help and it would be greatly appreciated. Code snipet is provided below. The "puts()" I/O function is used just to prove to myself that I have what I need to open this file. Any help on
this simple, yet frustrating endevour, would be great.
int CVICALLBACK OpenFilesUp (int panel, int control, int event,
void *callbackData, int eventData1, int eventData2)
char UserSelect[MAX_PATHNAME_LEN];//This variable is the buffer for the path of
                                                               //the file the user has selected.
                                                               //It holds the max value allowed for a path.
int FileHandle = -1;
switch (event)
case EVENT_COMMIT:
//The function below opens a file select box for the user to chose from a from a specific directory, type of default file, other leagal files,
//title of the dialog box, etc.
FileSelectPopup("c:\\Users\\vhouston\\Desktop\\201​1 Projects", "*.docx", "*.docx, *.doc, *.txt, *.dat", "File Selection", VAL_SELECT_BUTTON, 0, 0, 1, 1, UserSelect);
//The "OpenFile" function uses the buffer information gathered from the "FileSelectPopup" to open the
//user selected file. Currently this is set for read only, and opens with the pointer at the beginning of the file.
FileHandle = OpenFile(UserSelect, VAL_READ_ONLY, VAL_OPEN_AS_IS, VAL_ASCII);
puts(UserSelect);
break;
case EVENT_RIGHT_CLICK:
break;
return 0;

Hello, sorry for this late response: I was out of office these days.
CVI has the ability to interface with any ActiveX-capable application and comes with some examples to interface with MS Office applications: you should be able to find this example on your PC too. Additionally, there is the word report instrument, which even if aimed to generating reports through Word application should permit to read an existing word document (I'm not sure as I'm not using it actually).
Both instruments are interface to an existing application, i.e. Word must actually be installed on the target systm for these functions to operate. Be warned that Office Starter application is not suitable for this purpose as it lacks the ActiveX facility.
Proud to use LW/CVI from 3.1 on.
My contributions to the Developer Zone Community
If I have helped you, why not giving me a kudos?

Similar Messages

  • Simple openFile script

    I'm completely new to Director, but fairly fluent in Flash
    Actionscripting, which as I've found, it quite different.
    I've been playing about with ebooks, online tutorials and
    this forum trying to construct something, but to no avail. I would
    like to open a simple file. test e.g.
    function mouseUp(me) {
    button1.openFile("C:/autorun.inf", 1)
    when I run the script, I get an error saying "button1 is not
    defined ".
    Help would be greatly appreciated.
    jumpOnCommand

    In Flash you can write actionscript into either a frame
    script space or,
    to a limited extent, right on the object that you want use.
    In Director you normally write your code as a behavior and
    then attach
    that behavior to any number of sprites in the score. You can
    also write
    behavior style functions into the frame script space in the
    score.
    Additionally, you can write movie wide functions into movie
    script
    windows. There are two script window types, behavior and
    movie.
    Code that you write into a movie script is not attached to
    anything and
    has no direct connection to either the stage or the score. In
    a movie
    script window you can write any number of functions, and use
    as many
    windows as you like. This is somewhat similar to writing
    actionscript
    into a movie frame space.
    Any original content for a Director movie is placed into a
    cast. Every
    cast member has the same precedence. There is no heirarchical
    structure
    to Director assets as there is in Flash. Any cast member that
    is placed
    on the stage, or in the score, is an instance of that cast
    member and is
    called a sprite. You can only place one cast member instance
    in any
    sprite channel at any given frame. This is very differnt from
    Flash
    where you can place every asset into the same layer.
    Every sprite is self aware and self referential. It does not
    need to be
    assigned as a "button" or a "symbol" in order to be
    controlled. It does
    not need to be named in order to be addressed. A sprite does
    not need to
    be in the first frame of the score in order for Lingo to
    recognize it.
    Behavior code is usually written so that it can be assigned
    to any
    number of sprites. For instance, you can write one:
    on exitFrame
    go to the frame
    end
    function. And then use that throughout the score to stop the
    playback
    head. In Flash you have to write an individual stop();
    function in any
    keyframe where you want to stop the playback head.
    If you want to open an executable from a user action in your
    movie, you
    would:
    1. create the button artwork. If you want a complex button,
    you'll have
    to create one cast member for each state of the button.
    2. To operate the button, you can use one of the behaviors in
    the
    Library. You can also use one of these behaviors to have the
    cursor
    change. Attach these behaviors to the button sprite by
    dragging it from
    the Library to your sprite on the stage. If there are
    settable parameter
    values needed, then a window will open.
    3. To have this button call that executable, open the
    behavior that you
    attached and find the "on mouseUp me" function. Then you can
    add the
    open() function call to that function. If you need to find
    the user's
    desktop from your projector, you can use any of the OS xtras.
    BuddyAPI
    and fileXtra4 are the most popular. Each one comes with
    instructions.
    Most of this is covered in the tuturials that come with
    Director. You
    may want to look at those.
    Rob
    Rob Dillon
    Adobe Community Expert
    http://www.ddg-designs.com
    412-243-9119
    http://www.macromedia.com/software/trial/

  • CVI localtime to get the Day of the Year

    I have a vendor supplied driver that needs the day of the year (0-365), minutes, hours, seconds for their board so that it updates itself to the correct time. I am looking at the LabWindows/CVI functions time and localtime to get this information. Those calls are documented in   ...\CVI2010\include\ansi\time.h   with the code contained within  C:\windows\system32\cvirte.dll
    when I set up the module within TestStand, I get a message that states:
    This function either does not have parameter information in the DLL or user types not recognized by TestStand.
    Not a problem. I used the information within time.h to setup the parameters for the function time. That function works fine. The function localtime returns a structure with the individual time elements. I created a Custom Data Type to define the structure. I cannot seem to determine how to define the module for this action so that it will work.
    I am including the sequence file, .h file, and the dll to help you understand what I am attempting to acomplish. Perhaps I am not using the correct dll or there is a better option. Any help would be appreciated.
    NOTE: I could not attach a DLL so I renamed the extension to LLB. You will need to rename it back to DLL.
    Attachments:
    Test.seq ‏5 KB
    time.h ‏4 KB
    cvirte.llb ‏5686 KB

    Hey Bill,
    I think what might be causing issues is that you are calling directly into the CVI Run-Time Engine, which we do not publish an API for and generally do not intend to be called directly from another application. I would recommend creating a simple DLL in CVI to call the functions you want, such as localtime(). This will allow you to use the CVI function panels and other Help resources to correctly configure your function call. You can simply create a wrapper function which calls localtime and returns the value you are interested in. If you build this wrapper code into a DLL, you should be able to call it from TestStand.
    I hope this helps, and let me know if you have any more questions about it!
    Daniel E.
    TestStand Product Support Engineer
    National Instruments

  • CVI IDE: Is it possible to see list of functions for faster navigation?

    Colleagues,
    Very simple question about CVI IDE.
    Is it possible to see whole list of functions for fast and convenient navigation, like in Micro$oft Visual Studio:
    When I have C code with more than 20-30 functions and 2000+ lines - its a very inconvenient to scroll up and down every time...
    I guess this feature should present in CVI, or I missing something? 
    How you working with relative large projects in CVI? 
    Thank you in advance,
    Andrey.

    CVI offers the Source Code Browser, which shows informations about files, functions, variables, data types and macros in your code. The code browser can be accessed in several ways: the easiest is to position over an element in the code and press Ctrl+F1: the lower part of the workbench will host the Source Code Browser area (though you can lately release this window to position it wherever you find it useful). There are several other ways to access these informations: I suggest you to look in the online help, topic Using LabWindows/CVI >> Writing Source Code >> Browsing Source Code
    CVI has several other ways of navigating in your application:
    Select a panel, menu or control callback and press Ctrl+Shift+U to go to the object in the UIR editor
    Right-click on an element in the UIR editor to go to its callback (if any)
    Select a function call in the code editor and press Ctrl+I to go to the function source
    Select a filename and press Ctrl+U to open it in an editor window
    ... and others I don't remember now! 
    Message Edited by Roberto Bozzolo on 05-07-2010 10:12 AM
    Proud to use LW/CVI from 3.1 on.
    My contributions to the Developer Zone Community
    If I have helped you, why not giving me a kudos?

  • TCP client server sample

    All,
    This may not really be a LabWindows/CVI question but I'm really stuck on what should be easy to
    solve. The brain trust here on the forums has always been helpful so I'll try to explain.
    The project:
    Get LabWindows/CVI code talking to a muRata SN8200 embedded WiFi module.
    The setup:
    (running Labwindows/CVI 2009)
    Computer 1 -- (with a wireless NiC) running simple demo TCP server program provided by muRata.
    Computer 2 -- USB connection (virtual COM port) with simple program (also provided by muRata) that talks to the SN8200 embedded WiFi module.  This code along with the module creates a simple TCP client.
    Whats working:
    I can successfuly get the Computer 2 client connected to and talking to the Computer 1 server. (using the muRata supplied code)
    I can also run the LabWindows/CVI sample code from (\CVI2009\samples\tcp), server on computer 1 & client on computer 2 and they talk with no problems.
    (I'm using the same IP addresses and port numbers in all cases)
    Whats NOT working:
    Run the CVI server program on computer 1.
    I cannot get the muRata client program  to connect to the CVI server.
    I also tried get the CVI client program to connect to the muRata server.  No luck that way either. The CVI client sample program trys connect, and this function call:
    ConnectToTCPServer (&g_hconversation, portNum, tempBuf, ClientTCPCB, NULL, 5000 );
    returns with a timeout error code (-11).
    What I need:
    Some ideas on how to get this working.
    Is there something unique about the LabWindows/CVI sample client/server demo code that would make them incompatible with the muRata code?
    Can you think of some ways I can debug this further?  I feel like I'm kind of running blind.
    What else can I look at?
    For those that have read this far, thanks much and any ideas or comments will be appreciated,
    Kirk

    Humphrey,
    First,
    I just figured out what the problem is:
    When I was trying to use the CVI sample server I was entering the wrong port number.
    The reason I entered the wrong port was because the hard-coded port number in the muRata demo code was displayed in hex as 0x9069. ( I converted this to decimal and entered it into the CVI sample server code) The correct port number was 0x6990.  (upper and lower bytes swapped)  Arrgh!
    I found the problem by using the netstat command line utility to display the connections and noted that the port being used was not 0x9069.  It is really a problem with the muRata eval kit demo code.
    Second,
    Humphrey you are right about the CVI sample code not handling all the muRata commands for the client end of the connection that communicates with the SN8200 module.  For my test I was using the muRata code for that "end".
    The server end is simple and the CVI sample is adequate and is now working.
    Thank you to all who took the time to browse my questions,
    Kirk

  • Cannot load .lsb file of CIN

    I can create the .lsb file of a simple CIN in CVI 7.0 by following the steps in cintools\cvilvsb.h. I get
    messages ' creating a DLL with no exports' and 'No import libraries will be created'. I can create the .lsb file, but it never loads to the VI, the VI does not get executable. What am I missing ?

    Hello,
    I have found some informations on the NI website.
    General Informations.
    External Code for LabVIEW - CIN / DLL - Starting Point
    http://digital.ni.com/public.nsf/websearch/A6705FEC7EA42300862567B70054206E?OpenDocument
    Why Do I Get A Link Error When I Try To Build My LSB File to Use With My CIN in LabVIEW?
    http://digital.ni.com/public.nsf/websearch/46F50E3302115E4786256D7300787BEC?OpenDocument
    Tutorial: How to create a lsb file.
    http://zone.ni.com/devzone/conceptd.nsf/webmain/31DAB548C369B2C6862567C8006D8FC9?opendocument
    Hope this helps,
    best regards.
    Sebastian Nowoisky

  • Bidirectional coms with barcode scanner

    Hey everyone.  I'm trying to think big thoughts today.
    I have implemented a CVI 2012 app that used a Symbol / Motorola LI4278 barcode scanner.  Works well.  For that application, I went next-to-simplest method by pre-formatting the scanners into CDC driver mode to work with Win7 as virtual com ports.  Pretty simple then in CVI with a custom serial callback.
    So onto my "big idea" question.  It would be great to send warning beeps and LED blinks back to the user weilding the scanner.  Mot has an SDK that I've stared at, but it appears to be C++ only.  I'm not about to get in there and attempt a wrapper for it.
    I found this discussion here, and it sounds relevant, but I'm not sure where they got their device library.  So anyway, any thoughts on this?

    Hi ElectroLund,
    For the forum thread you linked in your previous post, he said the scanner in question came with a DLL. Since it seems your device did not come with a DLL and only a C++ library, it seems options are pretty limited. You could use a third party C++ development environment and create a DLL out of the C++ source code. This DLL could then be called within your C code.
    Unfortunately, since this is regarding communication with a third party device, National Instruments does not support the actual communication with the device. We can assist with calling DLLs and supported drivers. I would suggest contacting the maker of the barcode scanner to see if they have any DLLs or C source code to be used with their devices.
    David B.
    Applications Engineer
    National Instruments

  • In past versions of CVI, using OpenFile with no path meant to look in the local path (in other words the install directory). Is there a way to do this in CVI 2013?

    I use an .ini file to allow the users to change the bootup preferneces for the program. In the past that file lived in the install directory and OpenFile could cheerfully find the file and apply the preferences. In CVI 2013, the program seems to need an implicit path to the file. Is there a way around this?
    Solved!
    Go to Solution.

    I'm not using CVI2013 yet, but in any case you can build up a full pathname for a file in the application folder using GetProjectDir and MakePathname commands at runtime.
    Proud to use LW/CVI from 3.1 on.
    My contributions to the Developer Zone Community
    If I have helped you, why not giving me a kudos?

  • Send UI meassages from teststand sequence to Simple CVI Operator Interface with Asynchronous Timer

    Hello,
    Is it possible and how is it possible to send UI meassages from a teststand sequence to the Simple CVI Operator Interface with Asynchronous Timer which could be downloaded from NI Hompage. I use this problems because it is more stable than the standard OIs
    regards samuel

    This post could help:
    http://forums.ni.com/ni/board/message?board.id=330&message.id=7567
    Regards.

  • Very simple CVI-progra​m and question

    Hi
    I have just started working with CVI and, as far as I can see, the principle behind the interaction between various elemements is similar as in Delphi. I have made a very simple example (User Interface Application), containing a square command button and a numeric. My idea was to push the button, whereafter the NUMERIC-control displays some number. However, I can't seem to figure out how to construct change the function that is executed when pushing the button. I tried double-clicking, right-clicking, etc.., but I couldn't figure it out. I hope my question makes sense.
    Solved!
    Go to Solution.
    Attachments:
    untitled.JPG ‏11 KB

    I searched for litterature, but only found the Programmer Reference Manual (http://www.ni.com/pdf/manuals/323643a.pdf). The litterature you suggest seems very relevant, I'll take a look at it. Thanks.

  • CVI Simple UI modifications

    I am modifying the CVI Simple user interface (TestStand 4.1.1) and would like to have similar functionality using the SequenceCombo Box and SequenceView Box as the Full Featured User Interface has with the Sequence List Box and the SequenceView (STEPLISTVIEW) box.  So that when I select a Sequence in the ComboBox the steps are shown in the SequenceView Box.
    Thanks
    john
    Solved!
    Go to Solution.

    John -
    In the Simple UI, the SequenceView Control is connected to the ExecutionView Manager via the ExecutionViewMgr.ConnectExecutionView() method. When connected in this manner, the SequenceView displays the sequence execution specified by the ExecutionViewMgr.Execution property (when tracing is enabled).
    What you want is to have the SequenceView Control display the sequence, and its steps, at edit time. In order for a SequenceView Control to accomplish this, it must be connected to a SequenceFileView Manager via the SequenceFileViewMgr.ConnectSequenceView() method. When connected in this manner, the SequenceView displays, at edit time, the sequence specified by the SequenceFileViewMgr.Sequence property.
    A SequenceView Control can only be connected to one Manager control at a time and the Simple UI contains one SequenceView Control.
    You can either change the section of the code that connects the SequenceView Control to the ExecutionViewMgr and replace it with the appropriate code to connect it to the SequenceFileViewMgr, or you can add an additional SequenceView Control (in a new tab or tiled next to the original one) and connect it to the SequenceFileViewMgr in the manner described above. The implementation is up to you.
    Hope this helps.
    Manooch H.
    National Instruments

  • Error transact.cpp when load LabWindows CVI DLL

    Hie,
    I'm a "newbie" about LabView, and I would like to call a simple LabWindows CVI DLL from LabView. Then for this
    I did also a very simple VI (I think : 2 buttons, the first to call my DLL function and the second to quit
    my VI). I define my DLL as indicated by NI, all seems OK. After placing and defining parameters about my
    DLL function in the diagram, If I "double clic" on the DLL icon in my diagrram, I obtain :
    "Failure Transact.cpp, line 1132 ...blabla...blabla".
    Another Time, I obtained a message (when I try to run) about
    "not enough memory"
    the solution is then to kill LabView Process or shunt Down !!!!!
    I've tried my "mini" projet on tow systems and I obtained the same results :
    Wind
    ows 2000 and Windows NT
    LabView 6.0 et Lab Windows CVI 6.0
    144 Ram and 256 Ram in the two PC and not another application running during my test :
    I think then I should have enough ram to do this !
    I did not see my problem
    thank a lot in advance for any help
    file attachement contain hardcopy of VI
    Thierry
    Attachments:
    Bug_Memory_LabView.doc ‏56 KB

    Hie,
    Now It's OK !!
    After submitting my problem to NI, NI has transmitted to me a simple program :
    a VI which simply calls a function in a DLL (which loads an UIR), and their solution runs.
    Their solution is the "same" as mine except in mine, I have added calls to "MessagePopup"
    just to study how running my program like this (see "// Here ->x" ) :
    Extract of my code in my DLL :
    int __stdcall DllMain (HINSTANCE hinstDLL, DWORD fdwReason, LPVOID lpvReserved)
    int iValue=0;
    switch (fdwReason)
    case DLL_PROCESS_ATTACH:
    "// Here ->1" MessagePopup ("Avertissement", "DLL -> Init Ressources DLL LabWindows");
    if (InitCVIRTE (hinstDLL, 0, 0) == 0)
    return 0; /* out of memory */
    break;
    case DLL_PROCESS_DETACH:
    "// Here ->2" MessagePopup ("Avertissement", "DLL -> Free Ressources DLL LabWindows");
    if (!CVIRTEHasBeenDetached())
    CloseCVIRTE ();
    break;
    The problem is located to the line "// Here ->"
    When I drag the icon "Call Librairie function" in the diagram of my VI and I define parameters,
    immediately a "link" is established between LabView and the DLL, the __stdcall DllMain is called !
    then LabView Environnement failed !, you have then to kill the LabView Process !
    By changing the "MessagePopup" functions with tracks (*) in a file, I can "debug" my program and I will
    have never this artefacts.
    change line // Here ->1 with TraceMsg("DLL -> Init Ressources DLL LabWindows");
    change line // Here ->2 with TraceMsg("DLL -> Free Ressources DLL LabWindows");
    void TraceMsg(char *szBuffer)
    int iValue=0;
    int iHandle=0;
    iHandle = OpenFile("D:\\Thierry\\Formation LabView-LabWindows\\trace.log",
    VAL_WRITE_ONLY, VAL_APPEND, VAL_ASCII);
    iValue = WriteLine (iHandle, szBuffer,strlen(szBuffer));
    iValue =CloseFile (iHandle);
    Thierry

  • How can I create an application in MSVC 6.0 to access my FieldPoint modules with CVI 5.0 libraries?

    I have an application in CVI 5.0 that works. I am trying to export that so I can develop in MSVC. I need none of the UI provided in CVI, all I need are the simple FieldPoint commands provided in FieldPoint.obj. I have been stumped on this for weeks. I would write my own OPC client but the interface isn't even documented on what commands I would send if I did have an interface. I would prefer just to use the CVI libraries in MSVC 6.0. When I call the FP_Open function the program crashes with an RtlSizeHeap error.
    Thanks,
    Chad

    In theory, creating a dll that encapsulates the FieldPoint functions should work in MSVC. However, National Instruments has not tested MSVC interface, nor have we publicized that this type of setup will work, therefore making support unavailable. The other reason for why we do not offer support of FieldPoint in MSVC is that we have not seen a demand for such an interface. Therefore, I recommend that you create an OPC Client that communicates with the FieldPoint OPC Server. One example of such an OPC Client in MSVC is to use Datasockets, found in ComponentWorks++. You can find this example at the following web site:
    http://zone.ni.com/devzone/devzoneweb.nsf/opendoc?openagent&8FEAB5F73CFB68278625683A000B06ED&cat=7CDA3E51FEFC4AA2862568B80071A1E2
    If you are using the
    serial network module (FP-1000/1001), you can communicate with the FieldPoint modules using the Optomux protocol. For a complete listing of the Optomux commands refer to the FP-1000/1001 Programer Reference Manual located at the following web site:
    http://digital.ni.com/manuals.nsf/caba5d53e9b015a186256793004eebb7/bf97516ca18eee728625665e0063594e?OpenDocument
    Best Regards,
    JohnM

  • Error 1 is to open file vi:. Openfile occurred - Fehler 1 ist bei Open File .vi:Open File aufgetreten

    Hi there,
    I'm using Labview 7.1 and Windows 7.
    I built a VI and it ran perfectly yesterday. Today when I tried to run it, the following message appeared:
    Fehler 1 ist bei Open File+.vipen File aufgetreten
    Mögliche Gründe:
    LabVIEW:  Ein Ausgabeparameter ist ungültig.
    NI-488:  Befehl erfordert, daß der GPIB-Regler der aktive Regler ist.
    Translation (google translator):
    Error 1 is to open file vi:. Openfile occurred
    Possible reasons for this:
    LabVIEW: An input parameter is invalid.
    NI 488: command requires that the GPIB controller is the active controller.
    In the attachment I am sending the file. The file is very simple. I'm just importing some data from excel.
    Regards
    Solved!
    Go to Solution.
    Attachments:
    Error.jpg ‏49 KB

    Cottbus wrote:
    I have the VI in a loop, because I want to make operations with a specific cell from Excel in each iteration. First loop, use the first cell, second loop the second one and so on. Maybe there is another way to do that, but that is how I figured it ou. If you have any suggestions to make it simpler I appreciate.
    First of all, you don't have an "excel" file, which is a proprietary format. You have a delimited plain text table with semicolons separating columns and linefeeds separating rows.
    You have only one loop. You are probably talking about first iteration, second iteration etc.
    Your loop spins so fast that you will only see the last row after the VI has completed. Use a small wait.
    All you need is the following code (looks slightly different, because it is LabVIEW 2010). This will display all rows in sequence for however many rows you have. If you only want to display the first 5 rows, you can wire a 5 constant to the N of the FOR loop.
    LabVIEW Champion . Do more with less code and in less time .
    Attachments:
    ReadRows.png ‏3 KB

  • How to set a DMA transfer type for PXIe-6536 in LabWindows/CVI?

    I have a PXI chassis PXIe-1078 with a controller PXIe-8115 running under Windows 7. The digital output board is PXIe-6536.
    I use a function DAQmxSetChanAttribute to set a property DAQmx_DO_DataXferMech to a value DAQmx_Val_DMA, since I want to use a direct memory access data transfer. This wokred well with a PCI-6534 board using the same LabWindows/CVI code before migrating it to the PXIe system.
    Unfortunately, running this code on the PXIe system reports a DAQmx error -200452: "Specified property is not supported by the device or is not applicable to the task".
    The task is created in the following simple way (the board name in MAX is 'Dev1'):
       DAQmxCreateTask ("digTask", &digitalTask);
       DAQmxCreateDOChan (digitalTask, "Dev1/port0:3", "DIG_CHANNELS", DAQmx_Val_ChanForAllLines);
       DAQmxSetChanAttribute (digitalTask, "", DAQmx_DO_DataXferMech, DAQmx_Val_DMA, 15);
    How can I solve this problem? How is it possible to choose between different transfer types?
    Thank you in advance for any hint!

    Hi CavityQED,
    The PCI-6534 is a "Digital I/O" board while the PXIe-6536 is a "High Speed Digital I/O" board, that's why they don't have the same properties.
    By the way you can use DMA transfer with this method :
    http://zone.ni.com/reference/en-XX/help/370520J-01/hsdio/direct_dma/
    Let me know if it helps you.
    Regards.
    Mathieu_T
    Certified LabVIEW Developer
    Certified TestStand Developer
    National Instruments France
    #adMrkt{text-align: center;font-size:11px; font-weight: bold;} #adMrkt a {text-decoration: none;} #adMrkt a:hover{font-size: 9px;} #adMrkt a span{display: none;} #adMrkt a:hover span{display: block;}
    LabVIEW Tour
    Journées Techniques dans 10 villes en France, du 4 au 20 novembre 2014

Maybe you are looking for

  • How to read URL Parameters in ABAP WebDynpro ?

    Hi, How and where (which class, method) in ABAP WebDynpro we can read URL Parameters ? I found answers for WebDynpro JAVA but nothing for ABAP. Thanks Meenal

  • Regd  Infocube  0COPA_C01 .....Urgent

    Hi, I'm facing a problem while uploading data in to Infocube 0COPA_C01.For key figures (Revenue) there's data inj source system but in BW i'm not getting any data even in PSA.I've checked the transfer rules already. Thanks in advance Regards Prasanth

  • Email notiifcation when idoc failed

    I want send the mail to respective person when PO idoc failed. tell me the steps how to verify this senerio.

  • Hardware compatability list

    I was looking at an x86 Solaris 8 Hardware Compatability list yesterday... Didn't book mark it... Now I cant find it anywhere Argh... Anybody have a url:// to it.... Thanks in advance

  • Most Recent Updat

    During the most recent update of itunes i have encountered and error during each attempt to install the software. Also since attempting to do the install and failing the install my ipod will not connect or sync with my itunes. If anyone has had this