SRM Close PO Short

Hi Gurus,
Please help me on the following issue.
"When you do a final delivery in SRM and zero out the quantity to close the PR short, this does not transfer over to ECC.  Basically, the final delivery indicator is set in ECC, but the system will still allow you to do a goods receipt in ECC for the  quantity.  We have an example where the user closed PO  short in SRM (quantity remaining was 10)--we did a quantity of 0 and marked it for final delivery.  Now i was able to go into ECC to t-code MIGO for the goods receipt and saw the quantity of 10 still available to be received, even though the final delivery indicator was set in SRM."
Please help.
Reg,
Bis

Hello,
Strange behaviour...
You mean MIGO was allowed for concerned PO although its final delivery flag was set in R/3 ?
Regards.
Laurent.

Similar Messages

  • SRM Create Confirmation - Short Dump while adding Approver

    Dear Experts.
      Currently I am facing following issue.
    Issue:
      In SRM “Create Confirmation” Screen, when user click on check button and after that if user tries to add approver in approval tab then it is going to short dump. Please find the short dump info:
    Category ABAP Programming Error
    Runtime Errors UNCAUGHT_EXCEPTION
    Except. CX_OS_OBJECT_NOT_FOUND
    ABAP Program /SAPSRM/CL_WF_PROCESS_MANAGER=CP
    Application Component SRM-EBP-WFL
      I had analyzed this issue and following points are my findings.
    We have written code in BBP_DOC_CHECK_BADI to check the approver is added or not in approval tab. For this purpose we are using METHOD lo_conf_adv->/sapsrm/if_pdo_do_apv_ext~get_process_info (Here lo_conf_adv is object of interface /sapsrm/if_pdo_bo_conf_adv) and the instance of lo_conf_adv is getting from METHOD /sapsrm/cl_pdo_fact_conf_adv=>get_buffered_instance By pasing Doc GUID.
    As per my analysis, the above code only causing the short dump while adding the approver in aproval tab. More importantly the CHECK BADI (BBP_DOC_CHECK_BADI) is not triggered while adding the approver. 
    If I comment this code (which is mentioned in point 1), then the application is not giving any short dump and adding approver successfully.   
    I tried to find SAP notes but there are no SAP notes related to this issue. Also, I tried to find alternate METHOD to replace lo_conf_adv->/sapsrm/if_pdo_do_apv_ext~get_process_info but I have not got relevant method.     Please let me know if there is any solution for this issue.
    Thanks & Regards,
    Sasidhar V

    Hi Ritesh,
      Thanks for the fast response.
      We are using Process Controlled Workflow. In Doc Check BADI, we are checking the respective approver is added or not in approval tab in "Create Confirmation" Screen. While creating confirmation, when user click on "CHECK" button and If respective approver is not added then throwing error message.
      We are using Method "GET_PROCESS_INFO" to get approval information only. when this method is triggered in Check BADI then it is doing respective validations and displaying messages. After that when we try to add approver then the system trying to read entry from table "/SAPSRM/D_WF_003" by passing OID to LEVEL_GUID. But there is no entry in this table and that's why it is giving short dump.
      Can you please let me know why it is reading entry in that table and why entry is not exist.
      FYI, If I don't use method "GET_PROCESS_INFO" in check BADI then respective code where short dump happening is not triggering (System is not trying to read entry from /SAPSRM/D_WF_003 table) and so it is not giving short dump.
    Thanks & Regards,
    Sasidhar V.

  • SRM certification questions

    Hi Friends,
    i will be appearing in SRM certification very shortly. can anyone who has already appeared in the exam send me the questions OR send me any collection of question papers ?
    pls send to [email protected]
    thanks in advance.
    NB

    hi,
    Sent you some useful docs.
    BR,
    Disha.
    <b>Pls reward points for useful answers.</b>

  • Windows 10 Preview on Dell Venue 11 Pro Tablet

    Windows 10 Preview on Dell Venue 11 Pro
    Hardware
    Dell Venue 11 Pro (7130/7139) tablet computer with:
    Intel Core I3 4020Y processor (3MB Cache, 1.5GHz Dual-Core)
    4GB 1600MHz memory.
    128GB SSD.
    Lexar 64GB MicroSD memory card.
    Lexar 64GB USB memory card. (2 – used as needed, connected 
    via USB 3.0 port).
    10.8 inch IPS Display with FHD (1920 x 1080) resolution with 10-pt capacitive touch.
    Intel GT2 Graphics.
    Dell Active Stylus.
    Intel(R) 7260AC Dual-Band 2x2 802.11 ac WiFi + Bluetooth(R) 4.0
    Dell Wireless 5808E (LTE/HSPA/EVDO) Mobile Broadband Card - Verizon
    Factory installed OS: Microsoft Windows 8.1 (64 bit).
    Download
    Downloaded Windows 10 Technical Preview Enterprise Edition (64 bit) image file from:
    http://windows.microsoft.com/en-us/windows/preview.
    Download time < 15 minutes. File size 3.888GB.
    Download was smooth and apparently error free.
    Transfer of OS to USB Memory Card
    Rufus 1.4.10 application program was used to create a bootable USB Memory Card and to install the OS on this card. (http://rufus.akeo.ie/). The process was easy and was error free.
    Install Windows 10 on the Dell 11 Pro.
    A Dell factory backup was done to a bootable USB memory card. (Dell does not ship the Venue with any OS or other software on external media).
     The Rufus generated USB Memory Card was inserted into the Venue’s USB 3.0 port.
    Windows Explorer was used to display the USB files and to select and execute “Setup”.
    The Windows 10 installation asks if one wishes to keep the existing application programs, drivers and other current files. The recommended answer is YES. This was an unusual experience for me because the typical requirement is to do a clean install from
    a bootable device that is read on computer power up. It was very nice to be able to preserve the current application programs and drivers and to do the installation from “inside of” the old OS.
     The installation process was quick, there were no error messages or any obvious problems.
    There was no requirement for user responses during the process.
     The first tasks on initial start-up of the OS are to check for updates and to provide logon information.
    The update requirement depends on an operational connection to the Internet. In our case, the connection is by WiFi and there would normally by no way to initiate this without having been logged on to a running version of the OS. It is a typical “cart before
    the horse” problem. Fortunately, it is possible to defer this step which is what we did.
     The next problem is creating the logon. Dell’s default on display intensity is dimmer than is desirable and, at least on this tablet, it is difficult to see the contents of some of the logon fields. You cannot change the display intensity until after
    a successful logon. The “CAPTCHA” step is especially difficult and annoying. The dim display makes it tough to recognize the alphanumeric characters which may be on angles, overlapping, indistinct and of varying intensity. One has to guess about some of the
    characters, to change to different CAPTCHA selections and to repeatedly attempt a logon. My recommendation is not to use CAPTCHA in any part of the software.
     Microsoft encourages the use of a “Microsoft system wide” user name and password. 
    There are some advantages to this, but, as others have pointed out, it has some risks.
     Touch screen virtual keyboards are infamous for problems with accidental selections of adjacent keys and unintended character repetitions. Fortunately, the Venue 11 has a large sized virtual keyboard and there is less chance of key selection errors
    than is true with the small sized displays. The Venue does has problems with the unintended character repetitions. All of this causes difficulties with initial password setups in which the entered data are hidden with stars or other characters and one also
    usually has to enter the new password twice. A few software developers have started offering users a check box option for display of the entered password information. This is really helpful for reducing the number of times that one might need to enter a new
    password and then repeat it for confirmation.
    Initial Experience with Windows 10
    There have been no known problems with missing or incompatible drivers. I don’t know if any drivers were updated between 8.1 and 10 except that there was a somewhat lengthy automatic install of a new driver for the cellular modem. This device and its software
    have not been evaluated as yet. I do not know if the software enables regular cellular voice operations. It is unlikely that it enables the automatic transfer of voice communications between WiFi and Cellular networks, as is available from some vendors.
     Access to the Control Panel, Command Prompt and other administrative functions is now possible via the “Start” icon display once one realizes that you need to scroll the display fully downward and to the right in order to see the “administrative” icons.
     In spite of the relatively large Dell Venue display (10.8 inches), there are still many fields that are small and/or are too close together to be reliably selected by finger touch. Some of these fields cannot be selected at all by finger touch. The
    problem can be reduced by increasing character and display sizes and by the use of an Active Stylus. Use of a mouse plugged into the USB port is a temporary solution if one doesn’t have a stylus.
     There have been many instances of failures to respond to icon selections by repeated finger presses. The reason for this behavior is unknown. The problem can be temporarily cleared by a soft restart.
    In some fields, autofill correctly displays a list of choices, but the application program crashes with an unknown error message if you touch select one of the choices.
    There is a hardware “Windows button icon” that is located on the front rim of the computer, halfway between the right and left sides of the unit. This is a very poor location because it is easy to accidentally press the button while holding the computer
    in one’s hand. The button should be recessed and should be located on a side of the computer.
    There should be a mechanical button to increase or decrease screen intensity. There should be a user selectable option to control ambient light regulated screen intensity.
    This isn't necessarily a Windows 10 issue, but there has been a recent marked increase in advertisements that are added to the results of Google and Yahoo searches, e-mail traffic
    and other Internet transactions. The latest twist is that unless one accepts an advertisement's initial suggestion - usually by clicking on a YES or OK icon - then the display is locked and you cannot close it short of ending the task or doing a soft reset.
    There is no choice to Cancel. Selecting the X close icon or close on a drop down box doesn't close the advertising Window display.

    I'm running 9879 on my Venue Pro 11 and cannot get the stylus to work.
    Did you test that scenario? For such an early release of the OS, everything seems not too bad. But I really would like to be able to test OneNote with ink support!!

  • TRANSFER OF DATA FROM APPLICATION SERVER TO REPORT

    I have a file on application serverin T-code AL11(sap directories).I want to bring the data from this file to my report.
    Please explain me procedure with example.
    I approached below method:
    I approached with OPEN DATASET,But i got short dump.
    syntax:
    open dataset c_dset(file in app.svr.) for output in text mode
    encoding default.
    transfer c_dset to i_transfer(itab).
    close dataset.
    short dump:
    unable to open file "".
    Kindly solve my problem.

    Hi Saritha,
    If I am not wrong u r trying to read the data from the file which is on  the apps server rite?
    Use open data set with input for reading the file from application server ..........  output is to write the file onto the application server
    check the below sample code.......
    DATA:
    len TYPE i,
    text(30) type c,
    dir(30) TYPE c VALUE '/tmp/test.txt'.
    DATA: begin of data OCCURS 0,
    matnr type matnr,
    werks type werks_d,
    end of data.
    START-OF-SELECTION.
    CLEAR: text.
    OPEN DATASET dir FOR INPUT IN TEXT MODE.
    DO.
    READ DATASET dir INTO text.
    IF SY-SUBRC 0.
    EXIT.
    ENDIF.
    close dataset.

  • When opening a PDF I get a APPCRASH problem

    Im unable to open a PDF, the doc opens up but then closes very shortly afterwards, the problem is as follows
    Problem signature:
      Problem Event Name: APPCRASH
      Application Name: AcroRd32.exe
      Application Version: 11.0.10.32
      Application Timestamp: 547e9779
      Fault Module Name: AcroRd32.exe
      Fault Module Version: 11.0.10.32
      Fault Module Timestamp: 547e9779
      Exception Code: 40000015
      Exception Offset: 000e2f57
      OS Version: 6.1.7601.2.1.0.768.3
      Locale ID: 1033
      Additional Information 1: c37e
      Additional Information 2: c37eace044c7ca1363ee7c4cfb11aae7
      Additional Information 3: d9f6
      Additional Information 4: d9f66b0958125a38ecce91544b0025a9

    Duplicate topic https://forums.adobe.com/thread/1668761

  • Programs closing

    Hi!
    Suddenly my MacBook has started acting weird. All my programs will either not start, or shuts down after short time of use. Noticed problems with Safari and LimeWire at first, but now all my programs acts this way... Something has to be very wrong...
    When they shut down I get a message like: " The program has unexpectedly shut down", and three choices: "Close", "Report" or "Reopen". Don't know if this is exactly what it says, cause I run a Norwegian version of Mac OSX 10.4.8.
    Hope some of you can help me... It is very annoying in general, and even more when I do studying etc... I'm in school right now, using a lot of Excel, Word and PowerPoint, and suddenly all my work gets lost...
    (Sorry if my english isn't too good)
    Regards,
    Alexander Lauritzen
    13" MacBook 1,83GHz Intel Core Duo   Mac OS X (10.4.8)  

    Hi Adrian!!!
    Thanks for the tips, but didn't help
    I called Apple today, and they told me to use Disk Utility to repair the disk... Tried to do so, but Disk Utility told me that the Macintosh HD couldn't be either repaired or verified.
    I called Apple again, and they told me to reinstall OS X. I tried "Archive and install" several times (6(, and every time I got an error telling me to try again, wich I did a few times. Then i tried to format the Macintosh HD, and choose "Delete and Install", got a few errors again, but the third time it was succesfull!
    I was happy and tought the problem must have been solved, since everything was reinstalled. But I still have the same problem!!! Programs won't open, or closes after short time of use...
    So it has to be a hardware-problem, doesn't it???
    regards,
    Alexander Lauritzen

  • CS4 Encore keeps freezing during transcoding process.

    I'm using CS4 and trying to make a DVD that is 30 minutes long using Encore. It keeps freezing after about 5 minutes during the transcoding process and seems to always freeze at the same spot according to the progress bars.  I don't get an error message...it just stops and has to be forced to close.  Shorter videos seem to go through just fine as long as they are not over 12 minutes long.  Any ideas?  System is running Intel i7 975, 20gb ram, 2gb ddr5 Radeon video card.  I've made longer videos in the past...this is a new issue.

    >this is a new issue
    Some general things to try
    Run as Administrator http://forums.adobe.com/thread/969395 (Encore AND PPro)
    Odd Errors http://forums.adobe.com/thread/670174
    Long File Names or odd characters cause problems
    Read http://forums.adobe.com/thread/588273
    And #4 http://forums.adobe.com/thread/666558
    And This Message Thread http://forums.adobe.com/thread/665641

  • How to INCREASE Battery Capacity

    Just drop the advertising - I know that battery capacity  varies, and that the capacity of the phone battery - regardless of models, will degrade as the phone is used.
    I contest the "specialists" to provide some straight simple guidelines to how one can treat a battery to increase the capacity.
    That the layers gets closer and short-curcuits is a known reason. So, exposure to heat will make the substance that keep the layers apart into gas that escapes the battery. Now how can such a battery be fixed? In old days with NiCd we could freeze the battery to -36C, that would make the iodine to solid. if iodine is still used, this will still work. Other semiconductors needed more than -100C to regain state - but with access to liquid Nitrogen, that was fully possible. Maybe Ni is not so common, but freon is, and LPG (Butane/Propane liquified). A home freezer can at times go as low as -38C. 
    So, can charging in heat / cold change the capacity of the battery?
    Other: If I completely drain the battery between every charge - will that improve it?
    If I start to recharge it when it is 80% of capacity, and disconnect immediately and use everything, Bluetooth, WLAN - to drain it to 80% and the recharge - can I restore the good old capacity? 
    if the battery degrades to 10% of capacity, is it possible to restore it? How? 
    Don't change anything that works.

    That, and I've been reading to not constantly charge it, or leave it in at 100%. It can be charged too much from what I've seen. I've had mine since 2006 almost 2 years, and till recently left it charging all the time. Not sure that's been a good idea. This is Battery University website information...
    gure 1: Permanent capacity loss of lithium-ion as a function of temperature and charge level.
    High charge levels and elevated temperatures hasten permanent capacity loss. Improvements in chemistry have increased the storage performance of lithium-ion batteries.
    The mentioning of limited service life on lithium-ion has caused concern in the battery industry and I will need to add some clarifications. Let me explain:
    If someone asks how long we humans live, we would soon find out that the longevity varies according to life style and living conditions that exist in different countries. Similar conditions exist with the batteries, lithium-ion in particular. Since BatteryUniversity bases its information on the feedback from users as opposed to scientific information derived from a research lab, longevity results may differ from manufacturer' specifications. Let's briefly look at the various living conditions of the lithium-ion battery.
    The worst condition is keeping a fully charged battery at elevated temperatures, which is the case with running laptop batteries. If used on main power, the battery inside a laptop will only last for 12-18 months. I must hasten to explain that the pack does not die suddenly but begins with reduced run-times.
    The voltage level to which the cells are charged also plays an important role to longevity. For safety reasons, most lithium-ion cannot exceed 4.20 volts per cell. While a higher voltage boosts capacity, the disadvantage is lower cycle life. Figure 2 shows the cycle life as a function of charge voltage.

  • What is a inforecord? why do we need to maintain that?

    Hello,
    what is a inforecord? why do we need to maintain that?
    is it automatically created or manual?
    Thanks,

    Info Record is used for storing the purchasing information about a vendor and a material as the master data at purchasing organization and plant level. 
    Info Record consists of information that cannot be captured at the general vendor or material master level.  Info record allows buyers to quickly recognize which materials a specific vendor can supplier, and which vendors can supply a specified material.
    Info records are divided into General level and Purchasing Organization level.
         General level:
         Vendor Data u2013 e.g. vendor material number
         Origin data u2013 e.g. country of origin
         Order unit u2013  However, the variable order unit should be activated if there is different purchasing order unit with base unit of measure.
         General level Info Record text
         Purchasing org level
         Control data - planned delivery lead time, standard order quantity, minimum order quantity, shipping instruction, delivery tolerance
         Condition data - price conditions, price UOM, scales etc
         Last Purchase Order Number and date
         Purchasing level Info record text
    Prerequisite master data of setting up info record
    For info record of inventory item, a material master record and vendor master must exist in the system. 
    It is also possible to create info record of non-inventory item, material group and sort string key are required, and this kind of info record is used in external processing, where info record  number will be linked with a production order.
    Info record Category
    - Standard: Specifies that the info record is used in connection with standard purchase order.
    - Subcontracting: Specifies that the info record is used in connection with subcontract order (item category L).  The price should be the value added price which does not include the component value. Consignment: Specific that the info record is used in connection with consignment order (Item category K)
    - Pipeline: Specifies that the info record is used specifically for pipeline withdrawals. 
    Key fields of Info Record
    u2022     Planned Delivery time u2013 This is calendar day including transit lead time.  Note: For Info record of STO, the PDT is transit lead time only. 
    u2022     Standard QTY u2013 Standard Purchase Order QTY
    u2022     Minimum QTY u2013 Supplieru2019s minimum sales QTY
    u2022     Shipping instruction u2013 ship mode of this material from this vendor
    u2022     Confirmation Control key u2013 Indicate if a confirmation (AB) and shipping notification (LA) is expected. 
    u2022     Delivery Tolerance u2013 can be set with certain % to close PO short and allow over deliveries.
    u2022     Purchase Order Text u2013 will be copied over to purchasing document as Info record PO text
    u2022     Tax Code u2013 please do not enter tax code of affiliate info records, otherwise, it will cause error in invoice posting.
    Prashant

  • Just When You Thought it Was Safe to Go to the Grill

    Well, the backyard grilling session will never be the same: http://www.nydailynews.com/life-style/health/world-test-tube-burger-close-meat-short-flavo r-article-1.1417763
    I guess that one would serve "near-beer" with the "near-burger?"
    Hunt

    they did great job... nice...
    and YOU did great job on that !  good going !  really cool.
    re: lighting , camera , etc.. I was watching my new antenna tv last night for a few minutes...( got rid of cable provider for tv  so I can save $$ )... and was watching 'lifeboat'.
    black and white, hitchcock IIRC ? and takes place on a small boat. This is hard to do. It would work well as a play on stage probably ( for all I know it was a play before it was a film ? ).  But to do this as a film is very challenging for everyone. actors, crew etc.
    For one thing it can get really boring fast cause you're stuck in this small 'space' ...( submarine movies are like this too, very challenging..which is why I liked Das Boot ). Also, there was some movie about conquistidors on a river ( raft ) ...by werner herzog
    http://www.imdb.com/title/tt0068182/
    that was really well done...in terms of being cramped for "space" but keeping the story dynamic.
    Soooo, I was sorta watching the lifeboat thing and I know it's on a stage. It's not outside. I know it's lit to make it look like it is outside ( sunlight and big outdoor type lighting ).
    I also know it is all 'hard light " ( getting back to the definition of lights )... and for the iso ( then it was called asa ) of the film, I KNOW the hard lights were arc lamps and really BIG hard lights ...
    There was not a single soft light on this stage and the look of the thing was pretty impressive to me.
    For one thing, it really looks like it is shot outside. Plus it looks like it is shot on the ocean. Plus it looks like these people ( actors) are really on a lifeboat... and THEN there's the actual story and characters and so on...
    So when I SEE something done well, like your edit , and the product etc. I really appreciate it.
    Thanks you warthog !

  • Latest iTunes 8 must hate me...

    Well, after upgrading my iTunes, I'm having issues, yet again. I had to get the latest version of iTunes and after the long grueling but successful download I can't open it now. I get a message telling me that iTunes has encountered a problem and needs to close. Short of banging my head on the keyboard, I don't know how to fix the problem. Will someone please help me out?

    Oye, I've got the same problem. If we were to uninstall iTunes altogether, and then re-install, would we not lose all our downloaded music?

  • Patterns, patterns, patterns... li'l help? Duke $s here!

    Duke dollars up for grabs...
    please see:
    http://forum.java.sun.com/thread.jsp?thread=334163&forum=31&message=1366727
    Sorry to repost...
    Awaiting flames ;)

    Hey. I skimmed over your code, and pardon me if I didn't read it close enough (short attention span). But, in the standard Decorator pattern implementation I expect to see a constructor for the Decorator class that takes an instance of the class to decorate, then delegates some method calls to the internal class, maybe after doing some pre-processing, and maybe post-processing the data returned. I didn't see that here - you say that your JFileChooserDecorator class extends Component, I would think it would extend JFileChooser?
    hmmmm
    Lee

  • Open and close a PO in web dynpro in SRM 7.0 screen .

    Hi All ,
    I am creating a PO in SRM 7.0 by using excel upload via web dynpro screen .
    After the upload , I see that there are some problems with the PO in web dynpro .
    For example , when i click on the line item it dumps and there are some other similar problems .
    When I save the PO close it and reopen it , the problem goes away . May be the system handles them in some way
    So , is there a way in which I can close and reopen the po through coding ?
    I know there are buttons at the top that close the PO , but some how I could not get the code for that .
    I will really appreciate the help here .
    Thanks in advance ,
    Ambar Patil.

    Hi...
    By first instance, i think that problem may be with uploading from excel. because sometimes excel data conversion will not done properly. So due to incorrect values, PO may go into dump..  that is my thought.
    if not lets wait for others answers
    Regards
    Srinivas

  • Reg: Sale Order short close at Schedule lines level

    Dear Gurus,
    Requirement is to close all open schedule lines beyond one month.
    In detailed. User Enters Manual Schedule Lines as per the requirement of the customer say for 6 months.
    for Eg . Sale order entered on 1st of august to Dec with 500 qty, schedule 100 qty/Month, manually in sale order.
    Now if business delivers only 90 out of 100. they need to short close that particular schedule line only not the entire sale order or line item. I tried with Delivery block at schedule lines level. but it is not working.
    If any one has come across this scenario please share with me.
    Regards
    Praveen

    If we apply a delivery block the pending qty will automatically add to the last schedule date. Ex. if there is 3 dates in the schedule lines, and there is some 50 qty pending in second date, and if u apply delivery block it will carry forward that pending 50 qty to the third schedule line and adds up with it.
    But in my case i just want to close that pending 50 qty in second line item.
    Regards
    Praveen
    Edited by: Praveen_PG on Sep 15, 2011 1:28 PM

Maybe you are looking for