Strange problem in report Execution in test system

Hi,
As something strange going on my program in test system.
1) Executing the program in Development system using SE38->program name->F8. the program executes and display selection screen fraction of seconds.
issue:
When i am doing same process in TEST System(using SE38->program name->F8) the execution process is min 1 or 2 min , then i am gettign the Selection screen.
I have checked other programs in TEST System but it doesnu2019t happen to any other programs on TEST system.
Program functionality--
i am using 2 table and MARA and Z table,  Using Selection screen i am extracting the data into output screen and excel download
Dispaly
1)if user select the Radio button output to screen in selection screen
Display data into screen using some color formatted
2)if user select the Radio button output to file in selection screen
I am using OLE Automation Controller to get the Output excel download some color formatted data
please let me know how to rsolve this type of isssue in Test system...
plz respond when you find the time.
Regards,
AS
Moderator Message: Urgency downgraded.
Edited by: kishan P on Apr 13, 2011 11:59 AM

Yes ..
INITIALIZATION. Event  i have written code like free the objects ans clear Work Area and Refresh the Internal tables
And
*-to highlight the comments on selection-screen
  LOOP AT SCREEN.
    IF SCREEN-GROUP1 = 'RM1'.
      SCREEN-INTENSIFIED = '1'.
      MODIFY SCREEN.
    ENDIF.
  ENDLOOP.
Add entries to get the search help values
  PERFORM SEARCHELP_REGION.
  PERFORM SEARCHELP_COUNTRY.
At selection screen event i am getting the search help for the region and country
AT SELECTION-SCREEN ON VALUE-REQUEST FOR S_REGN-LOW.
*Search help for Region
  PERFORM SEARCHHELP_REGN_F4.
AT SELECTION-SCREEN ON VALUE-REQUEST FOR S_CTRY-LOW.
*Search help for Country
   PERFORM SEARCHHELP_CTRY_F4.
using FM :*FM for F4 help for returning the value to be displayed
  CALL FUNCTION 'F4IF_INT_TABLE_VALUE_REQUEST'
Please let me know is it couse problem in TEST System....
so how to resolve the issue...
Regards,
SR

Similar Messages

  • RAXINV - Strange problem in Report Builder

    I'm having a very wierd problem in Report builder 6.0.8.27.0. I'm simply trying to add two additional columns to the AR Invoice report (RAXINV) so that they get included in the XML output. This report has a main query called Q_INVOICE which is basically a dummy query to set the column aliases and at the end of the query it does a UNION with the user parameter &common_query.
    So, what I have done is gone into the common_query parameter and added the two extra dummy columns before the FROM statement (I've tried adding at different places but always the same result). Once that is done I've then gone into the Q_INVOICE query and added the same two columns. When I hit the OK button to update the query is when my problems start.
    There is a group in the report called G_ORDER_BY that has the field ORDER_BY in it. After clicking ok to update the query the G_ORDER_BY now has a field called BILL_CUST_NAME1, but the XML tag is still saying ORDER_BY. This happens to many fields in the report (the names are changed/corrupted) and as such the report is now useless as it won't compile.
    I have no idea why this would happen and I've never seen anything like this before.
    Can anyone provide any help on this ? I've logged an SR on this too but wanted to try here also incase someone had already crossed this problem.

    Dave,
    Not sure if its relevant or not, but I just fixed this issue, you need to change your query in three places, common_query parameter, build_query program unit and the main query itself in report editor.
    Cheers,
    Zeeshan

  • Strange problem crystal report & used-defined field

    I've a user-defined field in the table OCLG
    this field is alphanumeric linked to a user-defined table
    I've read this field in crystal report
    (at the moment is enough the code)
    when I do the preview in crystal report there is not problem
    but when I do the preview in SAP B1 I don't see any value
    what could it be the cause?
    thanks

    I created it with the follow tool:
    "Tools\Customisation Tools\User-Defined Fields-Management"
    These are the field characteristics:
    type: alphanumeric
    lenght: 50
    structure: regular
    set linked table: <a user-defined table>
    I also did the test to create a rpt with the only table OCLG and 2 field
    - ClgCode
    - U_Incaricato
    the problem remains the same

  • Strange problem with Domain Values

    Dear All,
      I encounter one strange problem with Domain Fixed Values.
    Background:
       We have a custom domain ( ZXREF2) created for custom data element(ZXREF2) which has replaced standard dataelement in BSEG for field XREF2. This domain has 12 Fixed values. The idea was to have F4 help for field "Reference Key2" in FBL5N/FBL01 tcodes. It is working fine with these 12 Fixed value, means, on F4 we could see all these 12 values and when selecting a line from F4 the entry got thru the screen validation ( plz note hat this validation is like checking the mandatory value so this is done even before PAI).
    Problem:
      The requirement was to add a new line to F4 values( tecnically, 13th record in domain ZXREF2). We added this line to domain and moved to Quality system. Its working fine in both Dev and Qality, but the strange problem occured after moving and testing in Production.
      In production, we could see all 13 lines in F4 help. <b>BUT</b>, after selecting the new one( 13th one), and after the value appears on screen field, when Enter is pressed, it gives error message "Enter Valid value".
       This error message also comes when we enter any value which is not there in F4. That means, system is able to recognize the new value in F4, but falied to validate that.
      We thought that, this might be the problem with Buffer, and request Client to re-start the system. Even after system restart, it still gives the same error message.
    Please note that, the error message is triggered even before PAI of the screen called. So noway( I already tried system debugging) we can debug this error message to findout the rootcause.
    Any quick help would be highly appriciated.
    Thanks and Regards,
    Prasad.

    Hello Max,
      I guess DB Utility ( SE14 ) is to be run only when there is a change at structure level, to make Runtime and Database objects in sync. Here, we just added a new line to existing domain, and this added a new row to the Database table DD07T/DD07L.
      Could you please expalin it more clearly if your view is different that what I just described. 
    Prasad.

  • Restrict table maintenance for a Z Table in SM30 in Test systems

    Hello,
    I have 2 Z tables ZTAB1 & ZTAB2 which has table maintenance created. Both tables should be non modifiable in Test systems  but should be able to make entries in DEV system.
    This means any entry that needs to be present in PROD or TEST systems for these tables should be moved through transports from DEV only.
    The Tables are defined as follows:
    The Delivery Class in Both Tables is 'C' and both table. In the table maintenance screen, the authorization group for ZTAB1 is ZT1 & for ZTAB2 is ZT2. The Authorization object is  S_TABU_DIS for Both tables.
    ZTAB1 has 2 screens for maintenance and ZTAB2 has 1 screen for maintenance.
    The recording routine is "Standard recording routine" for both tables.
    The Problem is as follows:
    In TEST system, In SM30 for table ZTAB2, when I click Maintain I get an error message "Client XXX status is 'not modifiable' " which is correct. That means we cannot modify the entries for this table in TEST system.
    However for table ZTAB1, I am able to change the table entries through SM30.
    Could anyone suggest how to restrict for making entries in table ZTAB1 in SM30.
    I debugged SM30 for both tables & found that the SM30 program checks for an entry in OBJH table with the table name as OBJECTNAME and if the OBJCATEGORY in OBJH is equals 'CUST', it throws error message "Client XXX status is 'not modifiable' ".
    For the problematic table ZTAB1, the OBJH entry has 'APPL' and that is why we dont get the error message and the table entries are editable in SM30.
    (The transaction SOBJ can be used to changes OBJH entries. I haven't used this before. Not sure if I can use it to correct the problem.)
    Can anybody tell me how this OBJH gets populated when we create a Z table? 
    Could anyone suggest how to restrict for making entries in table ZTAB1 in SM30.
    Thanks,

    APPL stands for the Delivery Class A (Application Table)
    CUST stands for the Delivery Class C (Customizing Table) in table OBJH.
    It seems, the delivery class for the ZTAB1 has been changed from A (Application) to C(Customization). Try to delete the Table maintenance and regenerate it again.
    Regards,
    Naimesh Patel

  • Strange Problem with Forms (Smart Forms)

    I have lately been experiencing a strange problem with standard forms in the system. We have WebAS640 / ECC5.0 System. Soon after the initial run of patches, most forms in the system are showing the character '#' in place of formatted texts.
    I have searched the internet and most forums, but have not found a solution. Since this is the standard forms that i am talking about (unmodified and untouched) so i assumed this had something to do with our patch levels. However that is only an assumption.
    In particular i am having problem with the billing invoice type RD00, form name: LB_BIL_INVOICE. I have traced the problem to this much. The form shows the expected text, where no character format is applied to it. And where ever there is some character format, it just shows a string of hashes ('#'). The style being used by this form is LO_STYLE.
    I am also listing my patch levels in case that helps.
    SAP_BASIS     640             0014
    SAP_ABA             640             0014
    ST-PI             003C_640     0001
    PI_BASIS     2004_1_640     0006
    SAP_BW             350             0012
    SAP_HR             500             0005
    SAP_APPL     500             0006
    PI             2004_1_500     0004
    EA-IPPE             300             0004
    EA-RETAIL     500             0005
    EA-PS             500          0005
    EA-HR             500          0005
    EA-GLTRADE     500          0005
    EA-FINSERV     500          0005
    EA-DFPS      500          0005
    EA-APPL      500           0005
    Hope somebody can help in regard

    Hi Ashan!
    Interesting problem. You are seeing replacement characters, because assigned font(size) is not installed (somewhere, SAP or printer).
    But since this is completely standard, open an OSS-request - maybe it's not as fast as SDN, but I'm sure you will get a qualified answer (and solution).
    Regards,
    Christian

  • Strange problem: ORA-01403: no data found when report has a sort

    Hi,
    I have a report which behaves very strangely but only for one particular user. The report runs fine when no columns are set as sort-by in the report attributes. As soon as I try and set a column to sort (any column, it doesn't matter) this user gets the error message:
    failed to parse SQL query:
    ORA-01403: no data found
    appear where the report should be on the page. The rest of the page displays OK. No other users are affected. If I remove the sort then the report is OK for this user (unsorted though!)
    The report is a structured query with custom column headings, nothing unusual, quite basic. I have tried exporting and reimporting the page but it doesn't fix it. Same behaviour for this particular page in our test system as well.
    I could rebuild the page but I'd rather know what is wrong in case it happens to some other region.
    Thanks,
    Steve

    Steve,
    The reports engine stores the sort settings in the user preferences. This is done so that when you return to a report, it maintains the earlier sort settings. Like in your response to the HTML DB studio posting, you would keep your report sorted by "Created On" descending or ascending even when you come back another time. It's save to remove those preferences; all that's going to happen is that your users will see the report using the report's default settings the next time they go to that page. I will try to investigate this problem further, whatever additional information you can provide, will be helpful,
    Marc

  • Strange problem while execution of query....

    Hi Friends
    I am facing a strange problem while executing the query.
    I have one query ,its old one ,till yesterday everday it was working fine ,
    But today i am trying to execute that query ,execution process takes very long time ,finally no response from bw server.
    its an important report in our company
    I checked query , Every thing is ok ,bze i haven't made any changes
    So i need some suggetions  .like where can i check and what can i do?
    ASAP ....  So Please ...its very urgent....
    EVERY THING AND ANY THING WILL BE REWARED
    Thanks in advance
    RK

    Hi
    Stefan
    Thank you for your valuable suggestion
    the problem is solved
    Already i  assigned  points.
    Thnaks & Regards
    RK

  • Strange Problem: cannot save public report as a developer

    HI all,
    I've testing an application in apex.oracle.com.
    Several days ago I started to have a strange problem with my application. I don't know what has been changed but I can't save the Interactive reports as a developer. The app doesn't display the button "apply" to save the changes, and in the design view  of the report the "Save public report authorization" select list is greyed.
    Is there anyone that knows where is this permission managed?
    Thanks in advance

    To choose an authorization scheme under "Save Public Report Authorization", you first must check the "Save Public Report" checkbox under "Include in Actions Menu".
    Note that both the "Save Report" as well as the "Save Public Report" option work for authenitcated pages only.
    Regards,
    Vincent Deelen

  • Tracing report execution Problem

    I am trying to trace report execution which gives me some problems!!!
    First i tried to use report builder (via tools --> trace option) to add tracing options and then when i executed the report using View--> Runtime Priview it does not produce the trace file. This works if i am using Live Previewer instead of Runtime Preview.
    But what i need is the trace file of runtime Previewer as it is giving me some problem.
    If i programatically do it using report triggers using SRW built-in packages then the report builder itself closes and says RWBLD60 has generated an Error. Since my report is very complex i need the help of report tracing to confirm the flow and execution. Please can somebody shed some light into this problem....
    It will be great if anyone tell me how to do it!!!!!.
    i am using Windows 2000 & Reports 6i (6.0.8.11.3). IS THIS A BUG IN REPORTS 6i????
    Thanks
    Mahesh Mathew

    The first thing I would do if I were you would be to upgrade to the latest patch version (we're up to about 6.0.8.23 now).
    If you're still having problems with tracing you could contact support, or workaround by testing the report with rwrun60 and adding the tracing options on the command line.
    Regards,
    Danny

  • V I Engineering, Inc has immediate needs for Systems Engineers (Contract) and Senior Systems Engineers (Contract) (reporting to the Test Software and Integration Group Manager)

    Company: V I Engineering, Inc.
    Locations: Various - USA
    Salary/Wage: $negotiable
    Status: Hourly Contractor
    Relevant Work Experience: 5+ years system integration (LabVIEW/TestStand experience required)
    Career Level: Intermediate/Experienced
    Education Level: Bachelor's Degree
    Residency/Citizenship: USA Citizenship or Greencard required
    Driving Business Results through Test Engineering
    V I Engineering, Inc. has a vision for every client we engage. That vision is to achieve on-time and on-budget program launch more efficiently that the competition. To realize this vision, customers need to achieve predictable test systems development, eliminate waste in test information management, and drive increased leverage of test assets. An underlying requirement for all of these areas is metrics tracking and measurement based decision making.
    Job Description
    Ready to make a difference? Bring your experiences and skills to the industry leading test organization. Help us to continue to shape the way the world views test. We are seeking a talented Systems Engineer Contractor to be responsible for technical execution of successful projects in the Medical, Military, Transportation, Consumer Electronics and Aerospace Industries. The position will have very high visibility to customers and vendors. This is a very fast paced team with close customer contact and strong career development opportunities. A large part of the position is to identify, own and drive technical design, development and installation of test systems. You will work alongside other like-minded and equally talented engineers, and be creative in a fast-paced and flexible environment that encourages you to think outside the box. You will be available to spend extended periods at our customer sites to complete system installations.
    Required
    5+ years of Systems Integration experience
    3+ years LabVIEW experience
    1+ years TestStand experience
    Experience in Implementation and Delivery of Test Systems, including integration
    Experience in ATE usage and development
    Experience in building and Integrating Mechanical Fixtures
    Experience in Understanding the design of Circuit Boards as they relate to a total system, and their fault-finding
    Experience in Taking Part in Technical Teams throughout All Phases of Project Lifecycle
    Experience in Interfacing with Sub-vendors and Customers
    Ability to Multitask
    Comfortable Working on Various Team Sizes
    Excellent Communication Skills
    Desired
    Requirements generation and review experience
    National Instruments Hardware knowledge
    Experience with Source Code Control (SCC)
    Experience executing verification and validation for projects
    Experience generating and/or reviewing cost proposals
    RF Technology (DAQ, General RF Theory)
    FPGA (with LabVIEW)
    Professional software engineering processes and metrics experience
    TortoiseSVN
    V I Package Manager (VIPM)
    Experience with Projects for Regulated Industries
    MS Project
    Formal Education
    Technical degree (BS Engineering, Computer Science, Physics, Math)
    National Instruments Courses a plus
    National Instruments certification a plus
    Notes:
    Expected Travel Time is up to 50%.
    V I Engineering, Inc. offers a dynamic work environment and the flexibility of a small company.
    The Test Software and Integration Group values innovation, out-of-the-box thinking, high-tech toys and a fun / amazingly collaborative working environment. We're a National Instruments Select Integrator, and we're the closest you can get to playing with all the pre-released and new NI toys without joining the NI R&D team - and we get to play with them in the real world.
    To apply for this position, email a cover letter and resume to [email protected] with the subject "TSIG Systems Engineer (Contract) employment application".
    Copyright © 2004-2015 Christopher G. Relf. Some Rights Reserved. This posting is licensed under a Creative Commons Attribution 2.5 License.

    Edit
    Jeff

  • V I Engineering, Inc has immediate needs for Systems Engineers and Senior Systems Engineers (reporting to the Test Software and Integration Group Manager)

    Company: V I Engineering, Inc.
    Locations: Positions available in our Farmington Hills, MI Office
    Salary/Wage: $negotiable
    Status: Full Time, Employee
    Relevant Work Experience: 5+ years system integration (LabVIEW/TestStand experience preferred, but not required)
    Career Level: Intermediate (Non-Manager)
    Education Level: Bachelor's Degree
    Residency/Citizenship: USA Citizenship or Greencard required
    Driving Business Results through Test Engineering
    V I Engineering, Inc. has a vision for every client we engage. That vision is to achieve on-time and on-budget program launch more efficiently that the competition. To realize this vision, customers need to achieve predictable test systems development, eliminate waste in test information management, and drive increased leverage of test assets. An underlying requirement for all of these areas is metrics tracking and measurement based decision making.
    Job Description
    Ready to make a difference? Bring your experiences and skills to the industry leading test organization. Help us to continue to shape the way the world views test. We are seeking a talented Systems Engineer to be responsible for technical execution of successful projects in the Medical, Military, Transportation, Consumer Electronics and Aerospace Industries. The position will have high visibility to customers and vendors. This is a very fast paced team with close customer contact and strong career development opportunities. A large part of the position is to identify, own and drive technical design and development of test systems. You will work alongside other like-minded and equally talented engineers, and be creative in a fast-paced and flexible environment that encourages you to think outside the box.
    Required
    5+ years of Systems Integration experience
    Experience in Design and Implementation of Test Systems, including integration
    Experience in ATE usage and development
    Experience in reviewing of Mechanical Fixtures
    Experience in understanding the design of Circuit Boards as they relate to a total system
    Experience in Taking Part in Technical Teams throughout All Phases of Project Lifecycle
    Experience in Interfacing with Sub-vendors and Customers
    Ability to Multitask
    Comfortable Working on Various Team Sizes
    Excellent Communication Skills
    Desired
    Requirements generation and review experience
    National Instruments Hardware knowledge
    LabVIEW/TestStand experience
    Experience with Source Code Control (SCC)
    Experience executing verification and validation for projects
    Experience generating and/or reviewing cost proposals
    RF Technology (DAQ, General RF Theory)
    FPGA (with LabVIEW)
    Professional software engineering processes and metrics experience (statement coverage, code size, reuse measurement, etc)
    TortoiseSVN
    V I Package Manager (VIPM)
    UML
    Experience with Projects for Regulated Industries
    MS Project
    Formal Education
    Technical degree (BS Engineering, Computer Science, Physics, Math)
    National Instruments Courses a plus
    National Instruments certification a plus
    Notes:
    Expected Travel Time is up to 25%Re
    location assistance is possible.
    V I Engineering, Inc. offers incredible opportunities to grow and advance your career, a dynamic work environment and the flexibility of a small company.
    The Test Software and Integration Group values innovation, out-of-the-box thinking, high-tech toys and a fun / amazingly collaborative working environment. We're a National Instruments Select Integrator, and we're the closest you can get to playing with all the pre-released and new NI toys without joining the NI R&D team - and we get to play with them in the real world.
    To apply for this position, email a cover letter and resume to [email protected] with the subject "TSIG Systems Engineer employment application".
    Copyright © 2004-2015 Christopher G. Relf. Some Rights Reserved. This posting is licensed under a Creative Commons Attribution 2.5 License.

    Edit
    Jeff

  • Store z-table (during an report execution) in a BW system

    Is there a way (and how- an example) to store z-table (during an report execution) in a BW system. We would not like Ztables to reside in R/3
    Thank you in advance

    Is there a way (and how- an example) to store z-table (during an report execution) in a BW system. We would not like Ztables to reside in R/3
    Thank you in advance

  • Strange problem... Query runs faster, but report runs slow...

    Hi Gurus,
    We are using Report 10g on 10g Application server and solaris. we created a report on a table which has 10,000 rows. The report has 25 columns. when we run this query in Toad it took 12 sec for fetching all these 10,000 rows
    But when we run the report with Destype = 'FILE' and Desformat = 'DELIMITEDDDATA', it is taking 5 to 8 minutes
    to open in excel ( we concatenated mimetype=vnd-msexcel at the end of the url if the Destype=FILE). We removed the layout in the report as it is taking 10 to 15 mins to run to Screen with Desformat=HTML/PDF(formating pages taking more time). We are wondering why DELIMITEDDATA format is taking long time as it runs only query.
    Does RWSERVLET take more time of writing the data to the Physical file in the cache dir? Our cache size is 1 GB. we have 2 report servers clustered. Tracing is off.
    Please advise me if there are any report server settings to boost the performance.
    Thanks alot,
    Ram.

    Duplicate of Strange problem... Query runs faster, but report runs slow... in the Reports forum.
    [Thread closed]

  • Problem with BPS Reports after upgarding the system to BI.7

    Dear Experts,
    We are facing problem with the BPS Reports after upgarding the system to BI.7
    In 3.5system the reports are dispalyingthe data.
    we have copied the production system to X system and has migrated the same to BI.7.
    in the X system the reports are not showing the data and even we generated the web interfaces in X system.
    After giving the input to BPS Layout and when we go for output ,we are getting the message No Data has been found.
    when we chekced the corresponding cube data was existing.
    It would be a great help if any valuable suggestions to over come the problem.
    Regards,
    Sunil...

    Dear Andrey,
    i am facing an error while filling the set up table for 2LIS_11_VAITM in the source system.
    The error was "Company code has not been maintained for the sales documnet 1296".
    when i checked the document in the Header table VBAK,company code was blank for the document .
    Company code was there in the selections for the setup table.
    The error means that company code should be maintained for the sales document as per my knolwedge.i think document was not created properly in the source system.
    Could you please help me out to over come the problem.
    Regards,
    Sunil...