Sun Cluster 3.1 Synchronize crontab b/w nodes

Dear all
what is best way to synchronize crontab b/w nodes . is there any utility that comes with SC 3.1 to do the trick.
Regards

There isn't anything that will do this job. You would need to do it manually or link /var/spool/cron to some global directory. Of course, that doesn't solve the problem entirely because if you make changes on the file on one node, you would have to signal the crontab daemon to re-read the file on the other nodes too.
Not insurmountable, just tricky.
Tim
---

Similar Messages

  • LDOM SUN Cluster Interconnect failure

    I am making a test SUN-Cluster on Solaris 10 in LDOM 1.3.
    in my environment, i have T5120, i have setup two guest OS with some configurations, setup sun cluster software, when executed, scinstall, it failed.
    node 2 come up, but node 1 throws following messgaes:
    Boot device: /virtual-devices@100/channel-devices@200/disk@0:a File and args:
    SunOS Release 5.10 Version Generic_139555-08 64-bit
    Copyright 1983-2009 Sun Microsystems, Inc. All rights reserved.
    Use is subject to license terms.
    Hostname: test1
    Configuring devices.
    Loading smf(5) service descriptions: 37/37
    /usr/cluster/bin/scdidadm: Could not load DID instance list.
    /usr/cluster/bin/scdidadm: Cannot open /etc/cluster/ccr/did_instances.
    Booting as part of a cluster
    NOTICE: CMM: Node test2 (nodeid = 1) with votecount = 1 added.
    NOTICE: CMM: Node test1 (nodeid = 2) with votecount = 0 added.
    NOTICE: clcomm: Adapter vnet2 constructed
    NOTICE: clcomm: Adapter vnet1 constructed
    NOTICE: CMM: Node test1: attempting to join cluster.
    NOTICE: CMM: Cluster doesn't have operational quorum yet; waiting for quorum.
    NOTICE: clcomm: Path test1:vnet1 - test2:vnet1 errors during initiation
    NOTICE: clcomm: Path test1:vnet2 - test2:vnet2 errors during initiation
    WARNING: Path test1:vnet1 - test2:vnet1 initiation encountered errors, errno = 62. Remote node may be down or unreachable through this path.
    WARNING: Path test1:vnet2 - test2:vnet2 initiation encountered errors, errno = 62. Remote node may be down or unreachable through this path.
    clcomm: Path test1:vnet2 - test2:vnet2 errors during initiation
    CREATED VIRTUAL SWITCH AND VNETS ON PRIMARY DOMAIN LIKE:<>
    532 ldm add-vsw mode=sc cluster-vsw0 primary
    533 ldm add-vsw mode=sc cluster-vsw1 primary
    535 ldm add-vnet vnet2 cluster-vsw0 test1
    536 ldm add-vnet vnet3 cluster-vsw1 test1
    540 ldm add-vnet vnet2 cluster-vsw0 test2
    541 ldm add-vnet vnet3 cluster-vsw1 test2
    Primary DOmain<>
    bash-3.00# dladm show-dev
    vsw0 link: up speed: 1000 Mbps duplex: full
    vsw1 link: up speed: 0 Mbps duplex: unknown
    vsw2 link: up speed: 0 Mbps duplex: unknown
    e1000g0 link: up speed: 1000 Mbps duplex: full
    e1000g1 link: down speed: 0 Mbps duplex: half
    e1000g2 link: down speed: 0 Mbps duplex: half
    e1000g3 link: up speed: 1000 Mbps duplex: full
    bash-3.00# dladm show-link
    vsw0 type: non-vlan mtu: 1500 device: vsw0
    vsw1 type: non-vlan mtu: 1500 device: vsw1
    vsw2 type: non-vlan mtu: 1500 device: vsw2
    e1000g0 type: non-vlan mtu: 1500 device: e1000g0
    e1000g1 type: non-vlan mtu: 1500 device: e1000g1
    e1000g2 type: non-vlan mtu: 1500 device: e1000g2
    e1000g3 type: non-vlan mtu: 1500 device: e1000g3
    bash-3.00#
    NOde1<>
    -bash-3.00# dladm show-link
    vnet0 type: non-vlan mtu: 1500 device: vnet0
    vnet1 type: non-vlan mtu: 1500 device: vnet1
    vnet2 type: non-vlan mtu: 1500 device: vnet2
    -bash-3.00# dladm show-dev
    vnet0 link: unknown speed: 0 Mbps duplex: unknown
    vnet1 link: unknown speed: 0 Mbps duplex: unknown
    vnet2 link: unknown speed: 0 Mbps duplex: unknown
    -bash-3.00#
    NODE2<>
    -bash-3.00# dladm show-link
    vnet0 type: non-vlan mtu: 1500 device: vnet0
    vnet1 type: non-vlan mtu: 1500 device: vnet1
    vnet2 type: non-vlan mtu: 1500 device: vnet2
    -bash-3.00#
    -bash-3.00#
    -bash-3.00# dladm show-dev
    vnet0 link: unknown speed: 0 Mbps duplex: unknown
    vnet1 link: unknown speed: 0 Mbps duplex: unknown
    vnet2 link: unknown speed: 0 Mbps duplex: unknown
    -bash-3.00#
    and this configuration i give while setting up scinstall
    Cluster Transport Adapters and Cables <<<You must identify the two cluster transport adapters which attach
    this node to the private cluster interconnect.
    For node "test1",
    What is the name of the first cluster transport adapter [vnet1]?
    Will this be a dedicated cluster transport adapter (yes/no) [yes]?
    All transport adapters support the "dlpi" transport type. Ethernet
    and Infiniband adapters are supported only with the "dlpi" transport;
    however, other adapter types may support other types of transport.
    For node "test1",
    Is "vnet1" an Ethernet adapter (yes/no) [yes]?
    Is "vnet1" an Infiniband adapter (yes/no) [yes]? no
    For node "test1",
    What is the name of the second cluster transport adapter [vnet3]? vnet2
    Will this be a dedicated cluster transport adapter (yes/no) [yes]?
    For node "test1",
    Name of the switch to which "vnet2" is connected [switch2]?
    For node "test1",
    Use the default port name for the "vnet2" connection (yes/no) [yes]?
    For node "test2",
    What is the name of the first cluster transport adapter [vnet1]?
    Will this be a dedicated cluster transport adapter (yes/no) [yes]?
    For node "test2",
    Name of the switch to which "vnet1" is connected [switch1]?
    For node "test2",
    Use the default port name for the "vnet1" connection (yes/no) [yes]?
    For node "test2",
    What is the name of the second cluster transport adapter [vnet2]?
    Will this be a dedicated cluster transport adapter (yes/no) [yes]?
    For node "test2",
    Name of the switch to which "vnet2" is connected [switch2]?
    For node "test2",
    Use the default port name for the "vnet2" connection (yes/no) [yes]?
    i have setup the configurations like.
    ldm list -l nodename
    NODE1<>
    NETWORK
    NAME SERVICE ID DEVICE MAC MODE PVID VID MTU LINKPROP
    vnet1 primary-vsw0@primary 0 network@0 00:14:4f:f9:61:63 1 1500
    vnet2 cluster-vsw0@primary 1 network@1 00:14:4f:f8:87:27 1 1500
    vnet3 cluster-vsw1@primary 2 network@2 00:14:4f:f8:f0:db 1 1500
    ldm list -l nodename
    NODE2<>
    NETWORK
    NAME SERVICE ID DEVICE MAC MODE PVID VID MTU LINKPROP
    vnet1 primary-vsw0@primary 0 network@0 00:14:4f:f9:a1:68 1 1500
    vnet2 cluster-vsw0@primary 1 network@1 00:14:4f:f9:3e:3d 1 1500
    vnet3 cluster-vsw1@primary 2 network@2 00:14:4f:fb:03:83 1 1500
    ldm list-services
    VSW
    NAME LDOM MAC NET-DEV ID DEVICE LINKPROP DEFAULT-VLAN-ID PVID VID MTU MODE INTER-VNET-LINK
    primary-vsw0 primary 00:14:4f:f9:25:5e e1000g0 0 switch@0 1 1 1500 on
    cluster-vsw0 primary 00:14:4f:fb:db:cb 1 switch@1 1 1 1500 sc on
    cluster-vsw1 primary 00:14:4f:fa:c1:58 2 switch@2 1 1 1500 sc on
    ldm list-bindings primary
    VSW
    NAME MAC NET-DEV ID DEVICE LINKPROP DEFAULT-VLAN-ID PVID VID MTU MODE INTER-VNET-LINK
    primary-vsw0 00:14:4f:f9:25:5e e1000g0 0 switch@0 1 1 1500 on
    PEER MAC PVID VID MTU LINKPROP INTERVNETLINK
    vnet1@gitserver 00:14:4f:f8:c0:5f 1 1500
    vnet1@racc2 00:14:4f:f8:2e:37 1 1500
    vnet1@test1 00:14:4f:f9:61:63 1 1500
    vnet1@test2 00:14:4f:f9:a1:68 1 1500
    NAME MAC NET-DEV ID DEVICE LINKPROP DEFAULT-VLAN-ID PVID VID MTU MODE INTER-VNET-LINK
    cluster-vsw0 00:14:4f:fb:db:cb 1 switch@1 1 1 1500 sc on
    PEER MAC PVID VID MTU LINKPROP INTERVNETLINK
    vnet2@test1 00:14:4f:f8:87:27 1 1500
    vnet2@test2 00:14:4f:f9:3e:3d 1 1500
    NAME MAC NET-DEV ID DEVICE LINKPROP DEFAULT-VLAN-ID PVID VID MTU MODE INTER-VNET-LINK
    cluster-vsw1 00:14:4f:fa:c1:58 2 switch@2 1 1 1500 sc on
    PEER MAC PVID VID MTU LINKPROP INTERVNETLINK
    vnet3@test1 00:14:4f:f8:f0:db 1 1500
    vnet3@test2 00:14:4f:fb:03:83 1 1500
    Any Idea Team, i beleive the cluster interconnect adapters were not successfull.
    I need any guidance/any clue, how to correct the private interconnect for clustering in two guest LDOMS.

    You dont have to stick to default IP's or subnet . You can change to whatever IP's you need. Whatever subnet mask you need. Even change the private names.
    You can do all this during install or even after install.
    Read the cluster install doc at docs.sun.com

  • Synchronize crontab on cluster

    Hello,
    Did anybody has an idea how we can synchronize the crontabs of the users in a Sun Cluster Environment.
    We have Zpool, so no "global" filesystems.
    Just for info:
    -> Solaris u8
    .> SunCluster 3.2 u3
    Best regards
    Joël

    user8689288 wrote:
    Please give me a good suggestion.Draw up proper functional specifications and business requirements. A solution is only as good as the problem definition.
    The problem description you provide is pretty vague and can be met using a number of different Oracle features. If you want a robust solution, you first need a comprehensive problem definition.

  • SUN Cluster 3.2, Solaris 10, Corrupted IPMP group on one node.

    Hello folks,
    I recently made a network change on nodename2 to add some resilience to IPMP (adding a second interface but still using a single IP address).
    After a reboot, I cannot keep this host from rebooting. For the one minute that it stays up, I do get the following result from scstat that seems to suggest a problem with the IPMP configuration. I rolled back my IPMP change, but it still doesn't seem to register the IPMP group in scstat.
    nodename2|/#scstat
    -- Cluster Nodes --
    Node name Status
    Cluster node: nodename1 Online
    Cluster node: nodename2 Online
    -- Cluster Transport Paths --
    Endpoint Endpoint Status
    Transport path: nodename1:bge3 nodename2:bge3 Path online
    -- Quorum Summary from latest node reconfiguration --
    Quorum votes possible: 3
    Quorum votes needed: 2
    Quorum votes present: 3
    -- Quorum Votes by Node (current status) --
    Node Name Present Possible Status
    Node votes: nodename1 1 1 Online
    Node votes: nodename2 1 1 Online
    -- Quorum Votes by Device (current status) --
    Device Name Present Possible Status
    Device votes: /dev/did/rdsk/d3s2 0 1 Offline
    -- Device Group Servers --
    Device Group Primary Secondary
    Device group servers: jms-ds nodename1 nodename2
    -- Device Group Status --
    Device Group Status
    Device group status: jms-ds Online
    -- Multi-owner Device Groups --
    Device Group Online Status
    -- IPMP Groups --
    Node Name Group Status Adapter Status
    scstat:  unexpected error.
    I did manage to run scstat on nodename1 while nodename2 was still up between reboots, here is that result (it does not show any IPMP group(s) on nodename2)
    nodename1|/#scstat
    -- Cluster Nodes --
    Node name Status
    Cluster node: nodename1 Online
    Cluster node: nodename2 Online
    -- Cluster Transport Paths --
    Endpoint Endpoint Status
    Transport path: nodename1:bge3 nodename2:bge3 faulted
    -- Quorum Summary from latest node reconfiguration --
    Quorum votes possible: 3
    Quorum votes needed: 2
    Quorum votes present: 3
    -- Quorum Votes by Node (current status) --
    Node Name Present Possible Status
    Node votes: nodename1 1 1 Online
    Node votes: nodename2 1 1 Online
    -- Quorum Votes by Device (current status) --
    Device Name Present Possible Status
    Device votes: /dev/did/rdsk/d3s2 1 1 Online
    -- Device Group Servers --
    Device Group Primary Secondary
    Device group servers: jms-ds nodename1 -
    -- Device Group Status --
    Device Group Status
    Device group status: jms-ds Degraded
    -- Multi-owner Device Groups --
    Device Group Online Status
    -- IPMP Groups --
    Node Name Group Status Adapter Status
    IPMP Group: nodename1 sc_ipmp1 Online bge2 Online
    IPMP Group: nodename1 sc_ipmp0 Online bge0 Online
    -- IPMP Groups in Zones --
    Zone Name Group Status Adapter Status
    I believe that I should be able to delete the IPMP group for the second node from the cluster and re-add it, but I'm sure about how to go about doing this. I welcome your comments or thoughts on what I can try before rebuilding this node from scratch.
    -AG

    I was able to restart both sides of the cluster. Now both sides are online, but neither side can access the shared disk.
    Lots of warnings. I will keep poking....
    Rebooting with command: boot
    Boot device: /pci@1e,600000/pci@0/pci@a/pci@0/pci@8/scsi@1/disk@0,0:a File and args:
    SunOS Release 5.10 Version Generic_141444-09 64-bit
    Copyright 1983-2009 Sun Microsystems, Inc. All rights reserved.
    Use is subject to license terms.
    Hardware watchdog enabled
    Hostname: nodename2
    Jul 21 10:00:16 in.mpathd[221]: No test address configured on interface ce3; disabling probe-based failure detection on it
    Jul 21 10:00:16 in.mpathd[221]: No test address configured on interface bge0; disabling probe-based failure detection on it
    /usr/cluster/bin/scdidadm: Could not stat "../../devices/iscsi/[email protected],0:c,raw" - No such file or directory.
    Warning: Path node loaded - "../../devices/iscsi/[email protected],0:c,raw".
    /usr/cluster/bin/scdidadm: Could not stat "../../devices/iscsi/[email protected],1:c,raw" - No such file or directory.
    Warning: Path node loaded - "../../devices/iscsi/[email protected],1:c,raw".
    Booting as part of a cluster
    NOTICE: CMM: Node nodename1 (nodeid = 1) with votecount = 1 added.
    NOTICE: CMM: Node nodename2 (nodeid = 2) with votecount = 1 added.
    WARNING: CMM: Open failed for quorum device /dev/did/rdsk/d3s2 with error 2.
    NOTICE: clcomm: Adapter bge3 constructed
    NOTICE: CMM: Node nodename2: attempting to join cluster.
    NOTICE: CMM: Node nodename1 (nodeid: 1, incarnation #: 1279727883) has become reachable.
    NOTICE: clcomm: Path nodename2:bge3 - nodename1:bge3 online
    WARNING: CMM: Open failed for quorum device /dev/did/rdsk/d3s2 with error 2.
    NOTICE: CMM: Cluster has reached quorum.
    NOTICE: CMM: Node nodename1 (nodeid = 1) is up; new incarnation number = 1279727883.
    NOTICE: CMM: Node nodename2 (nodeid = 2) is up; new incarnation number = 1279728026.
    NOTICE: CMM: Cluster members: nodename1 nodename2.
    NOTICE: CMM: node reconfiguration #3 completed.
    NOTICE: CMM: Node nodename2: joined cluster.
    NOTICE: CCR: Waiting for repository synchronization to finish.
    WARNING: CCR: Invalid CCR table : dcs_service_9 cluster global.
    WARNING: CMM: Open failed for quorum device /dev/did/rdsk/d3s2 with error 2.
    ip: joining multicasts failed (18) on clprivnet0 - will use link layer broadcasts for multicast
    ==> WARNING: DCS: Error looking up services table
    ==> WARNING: DCS: Error initializing service 9 from file
    /usr/cluster/bin/scdidadm: Could not stat "../../devices/iscsi/[email protected],0:c,raw" - No such file or directory.
    Warning: Path node loaded - "../../devices/iscsi/[email protected],0:c,raw".
    /usr/cluster/bin/scdidadm: Could not stat "../../devices/iscsi/[email protected],1:c,raw" - No such file or directory.
    Warning: Path node loaded - "../../devices/iscsi/[email protected],1:c,raw".
    /dev/md/rdsk/d22 is clean
    Reading ZFS config: done.
    NOTICE: iscsi session(6) iqn.1994-12.com.promise.iscsiarray2 online
    nodename2 console login: obtaining access to all attached disks
    starting NetWorker daemons:
    Rebooting with command: boot
    Boot device: /pci@1e,600000/pci@0/pci@a/pci@0/pci@8/scsi@1/disk@0,0:a File and args:
    SunOS Release 5.10 Version Generic_141444-09 64-bit
    Copyright 1983-2009 Sun Microsystems, Inc. All rights reserved.
    Use is subject to license terms.
    Hardware watchdog enabled
    Hostname: nodename1
    /usr/cluster/bin/scdidadm: Could not stat "../../devices/iscsi/[email protected],0:c,raw" - No such file or directory.
    Warning: Path node loaded - "../../devices/iscsi/[email protected],0:c,raw".
    /usr/cluster/bin/scdidadm: Could not stat "../../devices/iscsi/[email protected],1:c,raw" - No such file or directory.
    Warning: Path node loaded - "../../devices/iscsi/[email protected],1:c,raw".
    Booting as part of a cluster
    NOTICE: CMM: Node nodename1 (nodeid = 1) with votecount = 1 added.
    NOTICE: CMM: Node nodename2 (nodeid = 2) with votecount = 1 added.
    WARNING: CMM: Open failed for quorum device /dev/did/rdsk/d3s2 with error 2.
    NOTICE: clcomm: Adapter bge3 constructed
    NOTICE: CMM: Node nodename1: attempting to join cluster.
    NOTICE: bge3: link up 1000Mbps Full-Duplex
    NOTICE: clcomm: Path nodename1:bge3 - nodename2:bge3 errors during initiation
    WARNING: Path nodename1:bge3 - nodename2:bge3 initiation encountered errors, errno = 62. Remote node may be down or unreachable through this path.
    WARNING: CMM: Open failed for quorum device /dev/did/rdsk/d3s2 with error 2.
    NOTICE: CMM: Cluster doesn't have operational quorum yet; waiting for quorum.
    NOTICE: bge3: link down
    NOTICE: bge3: link up 1000Mbps Full-Duplex
    NOTICE: CMM: Node nodename2 (nodeid: 2, incarnation #: 1279728026) has become reachable.
    NOTICE: clcomm: Path nodename1:bge3 - nodename2:bge3 online
    WARNING: CMM: Open failed for quorum device /dev/did/rdsk/d3s2 with error 2.
    NOTICE: CMM: Cluster has reached quorum.
    NOTICE: CMM: Node nodename1 (nodeid = 1) is up; new incarnation number = 1279727883.
    NOTICE: CMM: Node nodename2 (nodeid = 2) is up; new incarnation number = 1279728026.
    NOTICE: CMM: Cluster members: nodename1 nodename2.
    NOTICE: CMM: node reconfiguration #3 completed.
    NOTICE: CMM: Node nodename1: joined cluster.
    WARNING: CMM: Open failed for quorum device /dev/did/rdsk/d3s2 with error 2.
    ip: joining multicasts failed (18) on clprivnet0 - will use link layer broadcasts for multicast
    /usr/cluster/bin/scdidadm: Could not stat "../../devices/iscsi/[email protected],0:c,raw" - No such file or directory.
    Warning: Path node loaded - "../../devices/iscsi/[email protected],0:c,raw".
    /usr/cluster/bin/scdidadm: Could not stat "../../devices/iscsi/[email protected],1:c,raw" - No such file or directory.
    Warning: Path node loaded - "../../devices/iscsi/[email protected],1:c,raw".
    /dev/md/rdsk/d26 is clean
    Reading ZFS config: done.
    NOTICE: iscsi session(6) iqn.1994-12.com.promise.iscsiarray2 online
    nodename1 console login: obtaining access to all attached disks
    starting NetWorker daemons:
    nsrexecd
    mount: /dev/md/jms-ds/dsk/d100 is already mounted or /opt/esbshares is busy

  • Information about Sun Cluster 3.1 5Q4 and Storage Foundation 4.1

    Hi,
    I have 2 Sunfire V440 with Solaris 9 last release 9/05 with last cluster patchs.. , Qlogic HBA fibre card on a seven disks shared on a Emc Clariion cx500. I have installed and configured Sun cluster 3.1 and Veritas Storage Foundation 4.1 MP1. My problems is when i run format wcommand on each node, I see the disks in a different order and veritas SF (4.1) is also picking up the disks in a different order.
    1. Storage Foundation 4.1 is compatible with Sun cluster 3.1 2005Q4?????
    2. Do you have a how to or other procedure for Storage foundation 4.1 with Sun Cluster 3.1.
    I'm very confuse with veritas Storage foundation
    Thanks!
    J-F Aubin

    This combination does not work today, but it will be available later.
    Since Sun and Veritas are two separate companies, it takes more
    time than expected to synchronize releases. Products supported by
    Sun for Sun Cluster installation undergo extensive testing, which also
    takes time.
    -- richard

  • Sun Cluster 3.0 and VxVM 3.2 problems at boot

    i 've a little problem with a two node cluster (2 x 480r + 2 x 3310 with a single raid ctl.)
    Every 3310 has 3 (raid5) luns .
    I've mirrored these 3 luns with VxVM, and i've mirror also the 2 internal (o.s.) disks.
    One of the disk of the first 3310 is the quorum disk.
    Every time i boot the nodes , i read an error at "block 0" of the quorum disk and then starts a fastidious synchronization of the mirrors. (sometimes also of the os mirror..)
    Why does it happen?
    Thanks.
    Regards,
    Mauro.

    We did another test today and again the resource group went into a STOP_FAILED state. On this occasion, the export for the corresponding ZFS pool timed-out. We were able to successfully bring the resource group online on the desired cluster node. Subsequent failovers worked fine. There's something strange happening when the zpool is being exported (eg error correction?). Once the zpool is exported, further imports of it seem to work fine.
    When we first had the problem, we were able to manually export and import the zpools, though they did take quite some time to export/import.
    "zpool list" shows we have a total of 7 zpools.
    "zfs list" shows we have a total of 27 zfs file systems.
    Is there any specific Sun or otherwise links to any problems with Sun Cluster and ZFS?

  • Does sun Cluster 3.0/3.1 HA Oracle agent support to use Oracle spfile?

    When defining the resource, the 'parameter_file' properties is usually sets to the Oracle pfile. Is it possible to use Oracle spfile?
    It is said if leaving 'parameter_file' NULL, it will be default to Oracle default. Suppose leaving it NULL and with Oracle spfile created in default location, will it use the spfile?

    You did not specify which Sun Cluster version and Oracle version you are running.
    Within SC 3.1 my understanding is that beginning with Oracle 9i it is possible to use the spfile.
    If you leave the "parameter_file" property empty (NULL) then the default behaviour for 9i should work:
    search under $ORACLE_HOME/dbs in the order:
    1. spfile$(ORACLE_SID}.ora
    2. spfile.ora
    3. init${ORACLE_SID}.ora
    Greets
    Thorsten

  • Encountered ora-29701 during Sun Cluster for Oracle RAC 9.2.0.7 startup (UR

    Hi all,
    Need some help from all out there
    In our Sun Cluster 3.1 Data Service for Oracle RAC 9.2.0.7 (Solaris 9) configuration, my team had encountered
    ora-29701 *Unable to connect to Cluster Manager*
    during the startup of the Oracle RAC database instances on the Oracle RAC Server resources.
    We tried the attached workaround by Oracle. This workaround works well for the 1^st time but it doesn’t work anymore when the server is rebooted.
    Kindly help me to check whether anyone encounter the same problem as the above and able to resolve. Thanks.
    Bug No. 4262155
    Filed 25-MAR-2005 Updated 11-APR-2005
    Product Oracle Server - Enterprise Edition Product Version 9.2.0.6.0
    Platform Linux x86
    Platform Version 2.4.21-9.0.1
    Database Version 9.2.0.6.0
    Affects Platforms Port-Specific
    Severity Severe Loss of Service
    Status Not a Bug. To Filer
    Base Bug N/A
    Fixed in Product Version No Data
    Problem statement:
    ORA-29701 DURING DATABASE CREATION AFTER APPLYING 9.2.0.6 PATCHSET
    *** 03/25/05 07:32 am ***
    TAR:
    PROBLEM:
    Customer applied 9.2.0.6 patchset over 9.2.0.4 patchset.
    While creating the database, customer receives following error:
         ORA-29701: unable to connect to Cluster Manager
    However, if customer goes from 9.2.0.4 -> 9.2.0.5 -> 9.2.0.6, the problem does not occur.
    DIAGNOSTIC ANALYSIS:
    It seems that the problem is with libskgxn9.so shared library.
    For 9.2.0.4 -> 9.2.0.5 -> 9.2.0.6, the install log shows the following:
    installActions2005-03-22_03-44-42PM.log:,
    [libskgxn9.so->%ORACLE_HOME%/lib/libskgxn9.so 7933 plats=1=>[46]langs=1=> en,fr,ar,bn,pt_BR,bg,fr_CA,ca,hr,cs,da,nl,ar_EG,en_GB,et,fi,de,el,iw,hu,is,in, it,ja,ko,es,lv,lt,ms,es_MX,no,pl,pt,ro,ru,zh_CN,sk,sl,es_ES,sv,th,zh_TW, tr,uk,vi]]
    installActions2005-03-22_04-13-03PM.log:, [libcmdll.so ->%ORACLE_HOME%/lib/libskgxn9.so 64274 plats=1=>[46] langs=-554696704=>[en]]
    For 9.2.0.4 -> 9.2.0.6, install log shows:
    installActions2005-03-22_04-13-03PM.log:, [libcmdll.so ->%ORACLE_HOME%/lib/libskgxn9.so 64274 plats=1=>[46] langs=-554696704=>[en]] does not exist.
    This means that while patching from 9.2.0.4 -> 9.2.0.5, Installer copies the libcmdll.so library into libskgxn9.so, while patching from 9.2.0.4 -> 9.2.0.6 does not.
    ORACM is located in /app/oracle/ORACM which is different than ORACLE_HOME in customer's environment.
    WORKAROUND:
    Customer is using the following workaround:
    cd $ORACLE_HOME/rdbms/lib make -f ins_rdbms.mk rac_on ioracle ipc_udp
    RELATED BUGS:
    Bug 4169291

    Check if following MOS note helps.
    Series of ORA-7445 Errors After Applying 9.2.0.7.0 Patchset to 9.2.0.6.0 Database (Doc ID 373375.1)

  • SAP 7.0 on SUN Cluster 3.2 (Solaris 10 / SPARC)

    Dear All;
    i'm installing a two nodes cluster (SUN Cluster 3.2 / Solaris 10 / SPARC), for a HA SAP 7.0 / Oracle 10g DataBase
    SAP and Oracle softwares were successfully installed and i could successfully cluster the Oracle DB and it is tested and working fine.
    for the SAP i did the following configurations
    # clresource create -g sap-ci-res-grp -t SUNW.sap_ci_v2 -p SAPSID=PRD -p Ci_instance_id=01 -p Ci_services_string=SCS -p Ci_startup_script=startsap_01 -p Ci_shutdown_script=stopsap_01 -p resource_dependencies=sap-hastp-rs,ora-db-res sap-ci-scs-res
    # clresource create -g sap-ci-res-grp -t SUNW.sap_ci_v2 -p SAPSID=PRD -p Ci_instance_id=00 -p Ci_services_string=ASCS -p Ci_startup_script=startsap_00 -p Ci_shutdown_script=stopsap_00 -p resource_dependencies=sap-hastp-rs,or-db-res sap-ci-Ascs-res
    and when trying to bring the sap-ci-res-grp online # clresourcegroup online -M sap-ci-res-grp
    it executes the startsap scripts successfully as following
    Sun Microsystems Inc.     SunOS 5.10     Generic     January 2005
    stty: : No such device or address
    stty: : No such device or address
    Starting SAP-Collector Daemon
    11:04:57 04.06.2008 LOG: Effective User Id is root
    Starting SAP-Collector Daemon
    11:04:57 04.06.2008 LOG: Effective User Id is root
    * This is Saposcol Version COLL 20.94 700 - V3.72 64Bit
    * Usage: saposcol -l: Start OS Collector
    * saposcol -k: Stop OS Collector
    * saposcol -d: OS Collector Dialog Mode
    * saposcol -s: OS Collector Status
    * Starting collector (create new process)
    * This is Saposcol Version COLL 20.94 700 - V3.72 64Bit
    * Usage: saposcol -l: Start OS Collector
    * saposcol -k: Stop OS Collector
    * saposcol -d: OS Collector Dialog Mode
    * saposcol -s: OS Collector Status
    * Starting collector (create new process)
    saposcol on host eccprd01 started
    Starting SAP Instance ASCS00
    Startup-Log is written to /export/home/prdadm/startsap_ASCS00.log
    saposcol on host eccprd01 started
    Running /usr/sap/PRD/SYS/exe/run/startj2eedb
    Trying to start PRD database ...
    Log file: /export/home/prdadm/startdb.log
    Instance Service on host eccprd01 started
    Jun 4 11:05:01 eccprd01 SAPPRD_00[26054]: Unable to open trace file sapstartsrv.log. (Error 11 Resource temporarily unavailable) [ntservsserver.cpp 1863]
    /usr/sap/PRD/SYS/exe/run/startj2eedb completed successfully
    Starting SAP Instance SCS01
    Startup-Log is written to /export/home/prdadm/startsap_SCS01.log
    Instance Service on host eccprd01 started
    Jun 4 11:05:02 eccprd01 SAPPRD_01[26111]: Unable to open trace file sapstartsrv.log. (Error 11 Resource temporarily unavailable) [ntservsserver.cpp 1863]
    Instance on host eccprd01 started
    Instance on host eccprd01 started
    and the it repeats the following warnings on the /var/adm/messages till it fails to the other node
    Jun 4 12:26:22 eccprd01 SC[SUNW.sap_ci_v2,sap-ci-res-grp,sap-ci-scs-res,sap_ci_svc_start]: [ID 183934 daemon.notice] Waiting for SAP Central Instance main dispatcher to come up.
    Jun 4 12:26:25 eccprd01 SC[SUNW.sap_ci_v2,sap-ci-res-grp,sap-ci-Ascs-res,sap_ci_svc_start]: [ID 183934 daemon.notice] Waiting for SAP Central Instance main dispatcher to come up.
    Jun 4 12:26:25 eccprd01 SC[SUNW.sap_ci_v2,sap-ci-res-grp,sap-ci-scs-res,sap_ci_svc_start]: [ID 183934 daemon.notice] Waiting for SAP Central Instance main dispatcher to come up.
    Jun 4 12:26:28 eccprd01 last message repeated 1 time
    Jun 4 12:26:28 eccprd01 SC[SUNW.sap_ci_v2,sap-ci-res-grp,sap-ci-Ascs-res,sap_ci_svc_start]: [ID 183934 daemon.notice] Waiting for SAP Central Instance main dispatcher to come up.
    Jun 4 12:26:31 eccprd01 SC[SUNW.sap_ci_v2,sap-ci-res-grp,sap-ci-scs-res,sap_ci_svc_start]: [ID 183934 daemon.notice] Waiting for SAP Central Instance main dispatcher to come up.
    Jun 4 12:26:31 eccprd01 SC[SUNW.sap_ci_v2,sap-ci-res-grp,sap-ci-Ascs-res,sap_ci_svc_start]: [ID 183934 daemon.notice] Waiting for SAP Central Instance main dispatcher to come up.
    Jun 4 12:26:34 eccprd01 SC[SUNW.sap_ci_v2,sap-ci-res-grp,sap-ci-scs-res,sap_ci_svc_start]: [ID 183934 daemon.notice] Waiting for SAP Central Instance main dispatcher to come up.
    Jun 4 12:26:34 eccprd01 SC[SUNW.sap_ci_v2,sap-ci-res-grp,sap-ci-Ascs-res,sap_ci_svc_start]: [ID 183934 daemon.notice] Waiting for SAP Central Instance main dispatcher to come up.
    Jun 4 12:26:37 eccprd01 SC[SUNW.sap_ci_v2,sap-ci-res-grp,sap-ci-scs-res,sap_ci_svc_start]: [ID 183934 daemon.notice] Waiting for SAP Central Instance main dispatcher to come up.
    Jun 4 12:26:37 eccprd01 SC[SUNW.sap_ci_v2,sap-ci-res-grp,sap-ci-Ascs-res,sap_ci_svc_start]: [ID 183934 daemon.notice] Waiting for SAP Central Instance main dispatcher to come up.
    Jun 4 12:26:40 eccprd01 SC[SUNW.sap_ci_v2,sap-ci-res-grp,sap-ci-scs-res,sap_ci_svc_start]: [ID 183934 daemon.notice] Waiting for SAP Central Instance main dispatcher to come up.
    Jun 4 12:26:40 eccprd01 SC[SUNW.sap_ci_v2,sap-ci-res-grp,sap-ci-Ascs-res,sap_ci_svc_start]: [ID 183934 daemon.notice] Waiting for SAP Central Instance main dispatcher to come up.
    Jun 4 12:26:43 eccprd01 SC[SUNW.sap_ci_v2,sap-ci-res-grp,sap-ci-scs-res,sap_ci_svc_start]: [ID 183934 daemon.notice] Waiting for SAP Central Instance main dispatcher to come up.
    Jun 4 12:26:43 eccprd01 SC[SUNW.sap_ci_v2,sap-ci-res-grp,sap-ci-Ascs-res,sap_ci_svc_start]: [ID 183934 daemon.notice] Waiting for SAP Central Instance main dispatcher to come up.
    Jun 4 12:26:46 eccprd01 last message repeated 1 time
    Jun 4 12:26:46 eccprd01 SC[SUNW.sap_ci_v2,sap-ci-res-grp,sap-ci-scs-res,sap_ci_svc_start]: [ID 183934 daemon.notice] Waiting for SAP Central Instance main dispatcher to come up.
    Jun 4 12:26:49 eccprd01 last message repeated 1 time
    Jun 4 12:26:49 eccprd01 SC[SUNW.sap_ci_v2,sap-ci-res-grp,sap-ci-Ascs-res,sap_ci_svc_start]: [ID 183934 daemon.notice] Waiting for SAP Central Instance main dispatcher to come up.
    Jun 4 12:26:52 eccprd01 last message repeated 1 time
    Jun 4 12:26:52 eccprd01 SC[SUNW.sap_ci_v2,sap-ci-res-grp,sap-ci-scs-res,sap_ci_svc_start]: [ID 183934 daemon.notice] Waiting for SAP Central Instance main dispatcher to come up.
    Jun 4 12:26:55 eccprd01 SC[SUNW.sap_ci_v2,sap-ci-res-grp,sap-ci-Ascs-res,sap_ci_svc_start]: [ID 183934 daemon.notice] Waiting for SAP Central Instance main dispatcher to come up.
    Jun 4 12:26:55 eccprd01 SC[SUNW.sap_ci_v2,sap-ci-res-grp,sap-ci-scs-res,sap_ci_svc_start]: [ID 183934 daemon.notice] Waiting for SAP Central Instance main dispatcher to come up.
    Jun 4 12:26:58 eccprd01 last message repeated 1 time
    Jun 4 12:26:58 eccprd01 SC[SUNW.sap_ci_v2,sap-ci-res-grp,sap-ci-Ascs-res,sap_ci_svc_start]: [ID 183934 daemon.notice] Waiting for SAP Central Instance main dispatcher to come up.
    Jun 4 12:27:01 eccprd01 last message repeated 1 time
    Jun 4 12:27:01 eccprd01 SC[SUNW.sap_ci_v2,sap-ci-res-grp,sap-ci-scs-res,sap_ci_svc_start]: [ID 183934 daemon.notice] Waiting for SAP Central Instance main dispatcher to come up.
    Jun 4 12:27:04 eccprd01 last message repeated 1 time
    Jun 4 12:27:04 eccprd01 SC[SUNW.sap_ci_v2,sap-ci-res-grp,sap-ci-Ascs-res,sap_ci_svc_start]: [ID 183934 daemon.notice] Waiting for SAP Central Instance main dispatcher to come up.
    Jun 4 12:27:07 eccprd01 SC[SUNW.sap_ci_v2,sap-ci-res-grp,sap-ci-scs-res,sap_ci_svc_start]: [ID 183934 daemon.notice] Waiting for SAP Central Instance main dispatcher to come up.
    Jun 4 12:27:07 eccprd01 SC[SUNW.sap_ci_v2,sap-ci-res-grp,sap-ci-Ascs-res,sap_ci_svc_start]: [ID 183934 daemon.notice] Waiting for SAP Central Instance main dispatcher to come up.
    Jun 4 12:27:10 eccprd01 SC[SUNW.sap_ci_v2,sap-ci-res-grp,sap-ci-scs-res,sap_ci_svc_start]: [ID 183934 daemon.notice] Waiting for SAP Central Instance main dispatcher to come up.
    Jun 4 12:27:10 eccprd01 SC[SUNW.sap_ci_v2,sap-ci-res-grp,sap-ci-Ascs-res,sap_ci_svc_start]: [ID 183934 daemon.notice] Waiting for SAP Central Instance main dispatcher to come up.
    Jun 4 12:27:13 eccprd01 last message repeated 1 time
    Jun 4 12:27:13 eccprd01 SC[SUNW.sap_ci_v2,sap-ci-res-grp,sap-ci-scs-res,sap_ci_svc_start]: [ID 183934 daemon.notice] Waiting for SAP Central Instance main dispatcher to come up.
    Jun 4 12:27:16 eccprd01 last message repeated 1 time
    Jun 4 12:27:16 eccprd01 SC[SUNW.sap_ci_v2,sap-ci-res-grp,sap-ci-Ascs-res,sap_ci_svc_start]: [ID 183934 daemon.notice] Waiting for SAP Central Instance main dispatcher to come up.
    Jun 4 12:27:19 eccprd01 SC[SUNW.sap_ci_v2,sap-ci-res-grp,sap-ci-scs-res,sap_ci_svc_start]: [ID 183934 daemon.notice] Waiting for SAP Central Instance main dispatcher to come up.
    Jun 4 12:27:19 eccprd01 SC[SUNW.sap_ci_v2,sap-ci-res-grp,sap-ci-Ascs-res,sap_ci_svc_start]: [ID 183934 daemon.notice] Waiting for SAP Central Instance main dispatcher to come up.
    Jun 4 12:27:22 eccprd01 last message repeated 1 time
    Jun 4 12:27:22 eccprd01 SC[SUNW.sap_ci_v2,sap-ci-res-grp,sap-ci-scs-res,sap_ci_svc_start]: [ID 183934 daemon.notice] Waiting for SAP Central Instance main dispatcher to come up.
    Jun 4 12:27:25 eccprd01 last message repeated 1 time
    Jun 4 12:27:25 eccprd01 SC[SUNW.sap_ci_v2,sap-ci-res-grp,sap-ci-Ascs-res,sap_ci_svc_start]: [ID 183934 daemon.notice] Waiting for SAP Central Instance main dispatcher to come up.
    Jun 4 12:27:28 eccprd01 SC[SUNW.sap_ci_v2,sap-ci-res-grp,sap-ci-scs-res,sap_ci_svc_start]: [ID 183934 daemon.notice] Waiting for SAP Central Instance main dispatcher to come up.
    Jun 4 12:27:28 eccprd01 SC[SUNW.sap_ci_v2,sap-ci-res-grp,sap-ci-Ascs-res,sap_ci_svc_start]: [ID 183934 daemon.notice] Waiting for SAP Central Instance main dispatcher to come up.
    Jun 4 12:27:31 eccprd01 SC[SUNW.sap_ci_v2,sap-ci-res-grp,sap-ci-scs-res,sap_ci_svc_start]: [ID 183934 daemon.notice] Waiting for SAP Central Instance main dispatcher to come up.
    Jun 4 12:27:31 eccprd01 SC[SUNW.sap_ci_v2,sap-ci-res-grp,sap-ci-Ascs-res,sap_ci_svc_start]: [ID 183934 daemon.notice] Waiting for SAP Central Instance main dispatcher to come up.
    Jun 4 12:27:34 eccprd01 last message repeated 1 time
    Jun 4 12:27:34 eccprd01 SC[SUNW.sap_ci_v2,sap-ci-res-grp,sap-ci-scs-res,sap_ci_svc_start]: [ID 183934 daemon.notice] Waiting for SAP Central Instance main dispatcher to come up.
    Jun 4 12:27:37 eccprd01 last message repeated 1 time
    Jun 4 12:27:37 eccprd01 SC[SUNW.sap_ci_v2,sap-ci-res-grp,sap-ci-Ascs-res,sap_ci_svc_start]: [ID 183934 daemon.notice] Waiting for SAP Central Instance main dispatcher to come up.
    Jun 4 12:27:40 eccprd01 SC[SUNW.sap_ci_v2,sap-ci-res-grp,sap-ci-scs-res,sap_ci_svc_start]: [ID 183934 daemon.notice] Waiting for SAP Central Instance main dispatcher to come up.
    Jun 4 12:27:40 eccprd01 SC[SUNW.sap_ci_v2,sap-ci-res-grp,sap-ci-Ascs-res,sap_ci_svc_start]: [ID 183934 daemon.notice] Waiting for SAP Central Instance main dispatcher to come up.
    Jun 4 12:27:43 eccprd01 last message repeated 1 time
    Jun 4 12:27:43 eccprd01 SC[SUNW.sap_ci_v2,sap-ci-res-grp,sap-ci-scs-res,sap_ci_svc_start]: [ID 183934 daemon.notice] Waiting for SAP Central Instance main dispatcher to come up.
    Jun 4 12:27:46 eccprd01 last message repeated 1 time
    Jun 4 12:27:46 eccprd01 SC[SUNW.sap_ci_v2,sap-ci-res-grp,sap-ci-Ascs-res,sap_ci_svc_start]: [ID 183934 daemon.notice] Waiting for SAP Central Instance main dis
    can anyone one help me if there is any error on configurations or what is the cause of this problem.....thanks in advance
    ARSSES

    Hi all.
    I am having a similar issue with a Sun Cluster 3.2 and SAP 7.0
    Scenrio:
    Central Instance (not incluster) : Started on one node
    Dialog Instance (not in cluster): Started on the other node
    When I create the resource for SUNW.sap_as like
    clrs create --g sap-rg -t SUNW.sap_as .....etc etc
    in the /var/adm/messages I got lots of WAITING FOR DISPACHER TO COME UP....
    Then after timeout it gives up.
    Any clue? What does is try to connect or waiting for? I hve notest that it's something before the startup script....
    TIA

  • Creating Logical hostname in sun cluster

    Can someone tell me, what exactly logical hostname in sun cluster mean?
    For registering logical hostname resource in failoover group, what exactly i need to specify
    for example, i have two nodes in sun cluster , How to create or configure a logical hostanme and it should point to which IP Address ( Whether it should point to IP addresses of nodes in sun cluster). Can i get clarification on this?

    Thanks Thorsten for ur continue help...
    The output of clrs status abc_lg
    === Cluster Resources ===
    Resource Name Node Name State Status Message
    abc_lg node1 Offline Offline
    node2 Offline Offline
    The status is offline...
    the output of clresourcegroup status
    === Cluster Resource Groups ===
    Group Name Node Name Suspended Status
    abc_rg node1 No Unmanaged
    node2 No Unmanaged
    You say that the resource should de enabled after creating the resource.. I am using GDS and i am just following the steps he provided to acheive high availabilty (in developers guide...)
    I have 1) Logical hostname resorce.
    2) Application resource in my failover resource group
    When i bring online the failover resource group , what should my failover resource group status and the status of resource in my resource group

  • File System Sharing using Sun Cluster 3.1

    Hi,
    I need help on how to setup and configure the system to share a remote file system that is created on a SAN disk (SAN LUN ) between two Sun Solaris 10 servers.
    The files in the remote system should be read/writabe from both the solaris servers concurrently.
    As a security policy NFS mount is not allowed. Some one suggested it can be done by using Sun Cluster 3.1 agents on both servers. Any details on how I can do this using Sun Cluster 3.1 is really appreciated.
    thanks
    Suresh

    You could do this by installing Sun Cluster on both systems and then creating a global file system on the shared LUN. However, if there was significant write activity on both nodes, then the performance will not necessarily what you need.
    What is wrong with the security of NFS? If it is set up properly I don't think this should be a problem.
    The other option would be to use shared QFS, but without Sun Cluster.
    Regards,
    Tim
    ---

  • Connected to an idle instance in sun cluster nodes.

    i have two sun cluster node sharing common storage.
    Two schema's:
    test1 for nodeA
    test2 for nodeB.
    My requirement is as below:
    Login into b node.
    export ORACLE_SID=test1.
    sqlplus / as sysdba.
    But i am getting as
    "connected to an idle instance"
    Is there any way to connect to node A schema from Node B.

    I found the answer..
    sqlplus <sysdbauser>/<password>@test1 as sysdba

  • Unable to download Sun Java System Identity Synchronization for Windows

    Please any one can help me How can i download Sun Java System Identity Synchronization for Windows
    * Sun Java System Directory Server ---------------------able to download
    * Sun Java System Directory Proxy Server --------------able to download
    * Sun Java System Identity Synchronization for Windows-------------Not able to download
    * Sun Java System Directory Editor------------------------able to download
    * Sun Java System Directory Server Resource Kit------able to download
    Regards
    kamal

    ISW is already present in the 5.2p4 and 5.2p6 archives.
    dn: cn=pswsync,cn=plugins,cn=config
    objectClass: top
    objectClass: nsSlapdPlugin
    objectClass: ds-signedPlugin
    objectClass: extensibleObject
    cn: pswsync
    nsslapd-pluginPath: /export/home/abc/local/ds52p6/lib/psw-plugin.so
    nsslapd-pluginInitfunc: pswsync_init
    nsslapd-pluginType: preoperation
    nsslapd-pluginEnabled: off
    creatorsName: cn=server,cn=plugins,cn=config
    modifiersName: cn=server,cn=plugins,cn=config
    createTimestamp: 20090121011643Z
    modifyTimestamp: 20090121011643Z
    nsslapd-pluginId: Identity Sync for Windows
    nsslapd-pluginVersion: 5.2_Patch_6
    nsslapd-pluginVendor: Sun Microsystems, Inc.
    nsslapd-pluginDescription: Identity Synchronization for Windows Plug-In

  • RAC 10g on Sun Cluster 3.1 U3 and Interconnect

    Hello,
    I have the following Interconnects on my Sun Cluster:
    ce5: flags=1008843<UP,BROADCAST,RUNNING,MULTICAST,PRIVATE,IPv4> mtu 1500 index 6
         inet 1.1.1.1 netmask ffffff80 broadcast 1.1.1.127
         ether 0:3:ba:95:fa:23
    ce5: flags=2008841<UP,RUNNING,MULTICAST,PRIVATE,IPv6> mtu 1500 index 6
         ether 0:3:ba:95:fa:23
         inet6 fe80::203:baff:fe95:fa23/10
    ce0: flags=1008843<UP,BROADCAST,RUNNING,MULTICAST,PRIVATE,IPv4> mtu 1500 index 7
         inet 1.1.0.129 netmask ffffff80 broadcast 1.1.0.255
         ether 0:3:ba:95:f9:97
    ce0: flags=2008841<UP,RUNNING,MULTICAST,PRIVATE,IPv6> mtu 1500 index 7
         ether 0:3:ba:95:f9:97
         inet6 fe80::203:baff:fe95:f997/10
    clprivnet0: flags=1009843<UP,BROADCAST,RUNNING,MULTICAST,MULTI_BCAST,PRIVATE,IPv4> mtu 1500 index 8
         inet 1.1.193.1 netmask ffffff00 broadcast 1.1.193.255
         ether 0:0:0:0:0:1
    In the Installation of RAC the routine will ask me which Interface I will use for RAC Interconnect and I do not know if it does not matter which Interface I choose, because I nevertheless in any case I have an SPOF.
    Can anybody help??
    Thank you very much

    Sorry for the late reply, but the interface to pick is the clprivnet0. This load-balances over the available private interconnects under the covers and so does not represent a single point of failure.
    Tim
    ---

  • 11g r2 non rac using asm for sun cluster os (two node but non-rac)

    I am going to install grid installation for non-rac using asm for two node sun cluster environment..
    How to create candidate disk in solaris cluster (sparc os) to install grid home in asm.. please provide me the steps if anyone knows

    Please refer the thread Re: 11GR2 ASM in non-rac node not starting... failing with error ORA-29701
    and this doc http://docs.oracle.com/cd/E11882_01/install.112/e24616/presolar.htm#CHDHAAHE