Hi everyone,
can anyone tell me how to suppress this message ......Message no. E2173....so i shall activate my table which dont have any technical setting...( i know that we can create the table without technical settings and i want solution)..
Thanks
Edited by: priya patil on Jun 30, 2008 10:13 AM
hi priya,
The technical settings of a table define how the table will be handled when it is created in the database, that is whether the table will be buffered and whether changes to data records of the table will be logged.
The most important parameters are:
Data class: The data class defines the physical area of the database (tablespace) in which the table should be created.
Size category: The size category defines the size of the extents created for the table.
When the table is created in the database, the required information about the memory area to be selected and the extent size is determined from the technical settings.
Buffering permission: The buffering permission defines whether the table may be buffered.
Buffering type: If the table may be buffered, you must define a buffering type (full, single-record, generic). The buffering type defines how many table records are loaded into the buffer when a table entry is accessed.
Logging: This parameter defines whether changes to the table entries should be logged. If logging is switched on, each change to a table record is recorded in a log table.
The Convert to transparent table flag ( transparent flag) is also displayed for pooled tables or for tables which were converted into transparent tables earlier on with this flag.
Now,the point is that table can't be maintained in the database without these above mentioned things.That's why answer to yr question is simple that we can't activate an table without techinacl settings.
Similar Messages
-
Size category in technical settings while creating database table
Hi all,
I am creating custom table in ABAP dictionary, while allocating size category in technical settings F4 help values are not coming.i am entering 0,but number of records expected range is not coming.i searched across SDN but couldn't find anything related to it.
Thanks in advance.
Sheela Patil
Edited by: Sheela Patil on Oct 4, 2011 7:21 PMHi
Check it properly it will dispaly the size ranges on clicking F4 button.
In this format it will display on clicking F4 button on size category field.
SzCat Number of data records of table expected
0 0 to 4,800
1 4,800 to 19,000
2 19,000 to 76,000
3 76,000 to 300,000
4 300,000 to 1,200,000
5 1,200,000 to 2,400,000
6 2,400,000 to 4,900,000
7 4,900,000 to 9,800,000
8 9,800,000 to 19,000,000
I hope it is solved for you. -
Table Technical settings for transfer data from developemnt to Quality
Hi All,
Please let me know which table techinical settings required for to transport table with data from development to quality?
Thanks & Regards,
padmaja.Hi,
You do not require technical settings to transport data from dvlpmnt to quality.
However, you can transport any tables entries with a simple trick:
(1) Create a workbench request
(2) Change the request (or its task) and add the following entry: R3TR TABU <name of table> =>
(3) Enter the key values you want to transport, e.g.:
- <client>* for all entries of the current client
- add additional restrictions for the table entry (<client><bukrs>* for all entries of a given company code)
Best regards,
Prashant -
How to modify a table without setting system to modifiable
Hi All
Is there a way to modify a table without setting the system to modifiable either in SCC4 or SE06.
We locked SCC4 in our system , however one tables are not able to modify.
table name YAUTM
Is there a way to bypass this?
Edited by: Shou Woon Wee on Jan 11, 2008 3:09 AMHi Shou......
if it gives you a message....."the client is not modifiable"/ ALIAS "table not modifiable" ...then from a security perspective....you cant, and you might not want to bypass it!
SCC4 settings are meant to be for that! Contact your Basis team for this.
The only way to bypass this is thru ....sending changes through a transport request.
Curiosity: what environment are you trying this out ? cant be sandbox or DEV!
Regards
Abhishek -
E-recruiting Technical Settings
Dear all,
We are implementing E-rec 6.0. Though E-rec is planned to be on a separate server, for basic configuration, we are doing config in Sandbox.
I have hired an employee, assigned the user id to IT105 subtype 001. I have assigned recruiter role to this employee as well.
I have done the follwoing technical settings;
CPERS - PROLE - BUP003 - Role of employee for business partner
PLOGI - PLOGI - 01 - Integration Plan Version / Active Plan Version
RECFA - AGYRO - RCFAGY - Role of Agency in Business Partner
RECFA - BL2UI - - RFC Connection from BL System (DB) to UI System
RECFA - BPCOU - - Country for Name Format of Business Partner
RECFA - BPNAM - - Name Format for Business Partner
RECFA - BRARO - RCFBRA -Branch Rule in Business Partner
RECFA - DATAO - - Output Technology for Data Overviews
RECFA - GARBC - - X = Call Garbage Collector (Firm)
RECFA - HIHIT - 500 - Maximum Number of Hits for All Search Requests
RECFA - HRQUA - X - Integration Switch for HR Qualifications
RECFA - HRRFC - - Logical System of Connected HR System
RECFA - HRXI - - XI Use for Data Exchange with HR
RECFA - IMSAV - - Activate Implicit Save in Candidate Profile
RECFA - INDCO - - Individual Correspondence with/without Web
When generate the URL for recruiter, and open it in internet explorer, am getting; 'An internal error occured; pl try again later'.
I have not done any config in SICF, SMICM etc. I doubt if some config is missing on BSP side.
Can anyone solve the above problem. This is very urgent need.
Thank you all in advance.
ShashiHi,
This is more question for the HCM forum.
Anyway, pls check the HTTP 500 section in this
https://wiki.sdn.sap.com/wiki/display/BSP/ExceptionsandErrors
Als check what ST22 is returning.
Eddy
PS. Reward the useful answers and you will get <a href="http:///people/baris.buyuktanir2/blog/2007/04/04/point-for-points-reward-yourself">one point</a> yourself! -
Retrieving technical settings for existing structure
Hi!
how to retrieve technical settings for existing structure? Is it somewhere in SE11?
Will reward,
Mindaugas.sorry you are right, it is my mistake - I wanted to create structure, but left radio box as for table... now I have created a table... is it possible to delete this table?
M. -
Hi All,
We are in the process of 4.7 to ECC 6.0 upgrade.
Please see the SPDD screen shot
http://docs.google.com/Doc?id=dctrtng5_0dqxqcw
In this what can we do with the issue related to BNKA table. It shows it is a warning with Technical setting.
I have verified with source system version of BNKA table technical settings with the upgrade shadow system BNKA table technical settings . I dont find any difference .
Please let me know what can i do .
Regards,
ReddyIt seems the changes to technical settings are reverted back but there is an entry in the log which populated this warning message so we went forward with ACT_XXX phase of upgrade.
-
Hi. How can I delete the table without deleting the content? My pages version is 5.2.2. Thank you for your help.
There is no convert Table to text capability in Pages v5.2.2, as there was in Pages ’09 v4.3.
You can keep the table while making the table grid vanish, leaving the existing tabular text structure. Select the table, and under the Format panel > Table tab, the following settings will produce this output. If selected, you can refine its document placement in the Arrange tab. -
Generic datasource technical settings: Data class : Transaction or Master?
Dear Experts,
I am not sure what is the difference in datasource technical settings (in R/3) : Data Class = Appl1 (transaction data) vs Data Class = Appl0 (master data).
The reason for asking is i have a z-table used as the table of a generic datasource and this table contains master data.
The Data Class is set as Transaction data.
It works. So, what is the difference if its set to Master data as the Data Class? Is there performance difference during data extraction?
Please advise.
regards
PascalHi,
Data classes are assigned during table creation and are maintained in technical settings,
Data class: By choosing data class some space will be allocated to the table in the database when it is created.
Each data class corresponds to a physical area in which all the tables assigned to this data class are stored.
There are 3 main data classes:
a) APPL0- Which is the master data. Data which will be rarely changed.
An example of master data can be like name, employee number and telephone number.
b) APPL1-Which is transaction data. Data that is frequently changed.
An example of transaction data is the goods in go down which will change as per the purchases.
c) APPL2-Which is organizational data. Customizing data that is defined when the system is installed and rarely changed.
Example may be table with country codes.
By assigning the data class to the table we can retrieve the data very easily.
There are also 2 more data classes USR and USR1, which are provided for the customer.
These are for the user developments. The tables assigned to these data classes are stored in a table space for user developments.
Regards,
Durgesh. -
Difference between Delta "Change Log" and "Active Table (Without Archive)"?
In BI7.0 environment, we perform our Delta loads (the DTP settings under the Extraction tab, there is a field called Extraction Mode and it's value is selected as "Delta") every day among all our DSOs.
There is a section called "Delta Init. Extraction From..." under the same tab in DTP, there are four radio buttons:
Active Table (With Archive)
Active Table (Without Archive)
Archive (Full Extraction Only)
Change Log
Then what is the difference between "Change Log" and "Active Table (Without Archive)" if both Extraction Mode is "Delta" for two Delta loads?
Thanks!Hi ,
The new options SP16 has are:(Chk Note 1096771)
Active Table (with Archive)
The data is read from the active table and from the archive or from a near-line storage if one exists. You can choose this option even if there is no active data archiving process yet for the DataStore object.
Active Table (Without Archive)
The data is only read from the active table. If there is data in the archive or in a near-line storage at the time of extraction, this data is not extracted.
Archive (Only Full Extraction)
The data is only read from the archive or from a near-line storage. Data is not extracted from the active table.
Change Log
The data is read from the change log of the DataStore object.
Delta will always be picked from change log table.Only during intialization you can choose between getting data from change log or active table.If you are doing the load first time and are initializzing delta in subsequent data targets, then pulling data from active table will get lesse volume of data then it would have got from change log table....All subsequent deltas will be picked up from the change log. And when we need to reload data into the data target (which would be a full load) - we use active table.
From change log : you can take below ones as targets
1) Cube 2) DSO with Addition as the update for the Keyfigures
From Active table: you can take below ones as targets
1) Cube ,if and only if, the records are never changes in the source once after creation
2) DSO with Addition as the update for the Keyfigures ,if and only if, the records are never changes in the source once after creation
3) DSO with Overwrite as the update for the Keyfigures ( incase deletions is not happening in the source system)
Pls check this link
http://help.sap.com/saphelp_nw70ehp1/helpdata/en/47/e8c56ecd313c86e10000000a42189c/frameset.htm
Regards,
CSM Reddy -
Displaying data in one row for for 2 tables without relaiton
I Have 2 tables without any relation and there is a common field and i want to display data like below
table refdet
1)
refdt----------refbr----refamt----refcat
10-aug-09---10-----34234-----101a
10-aug-009--11----23245-----102a
1-AUG-09----10----455.98----104A
19-aug-09-12-----10000-------103B
2) brdet
trdt---------brn-----brtot-----------brcat
11-aug09--10-----454000-------A
09-aug-09-12-----550000-------B
30-sep-09--10-----430000------A
09-aug-09-11-----550000-------B
i want to display data for each branch refdet.refbr = brdet.brn
refdet
Br10
refdt----------refbr----refamt----refcat-----trdt---------brn-----brtot-----------brcat
10-aug-09---10-----34234-----101a-------11-aug09--10-----454000-------A
1-AUG-09----10----455.98----104A------30-sep-09--10-----430000------A
Br 11
10-aug-009--11----23245-----102a -------09-aug-09-11-----550000-------B
Br12
19-aug-09-12-----10000-------103B------09-aug-09----12-----550000-------B
i tried the following query but its not working
select distinct null as refdt,null as refbr,null as refamt,null as refcat,b.trdt,b.brn,b.brtot,b.brcat
from brdet a,refdet b
where a.refbr (+) = b.brn
union all
select distinct a.refdt,a.refbr,a.refamt,a.refcat,null as trdt,null as brn,null as brtot,null as brcat
from brdet a,refdet b
where a.refbr = b.brn (+)
its not giving the records on each row for both side its creating separte rows for each records in both table.
rgds
jytohi
-Hi jytohi,
Please lean back for a moment and study your question. Ask yourself, is this a reasonable way to ask a question?
Jopefully you'll reach the answer, "No it isn't, I need to.."
1. Turn these
1)
refdt----------refbr----refamt----refcat
2) brdet
trdt---------brn-----brtot-----------brcatinto CREATE TABLE statements.
2. Turn these
10-aug-09---10-----34234-----101a
10-aug-009--11----23245-----102a
1-AUG-09----10----455.98----104A
19-aug-09-12-----10000-------103B
11-aug09--10-----454000-------A
09-aug-09-12-----550000-------B
30-sep-09--10-----430000------A
09-aug-09-11-----550000-------Binto INSERT INTO statements
3. Turn this
refdet
Br10
refdt----------refbr----refamt----refcat-----trdt---------brn-----brtot-----------brcat
10-aug-09---10-----34234-----101a-------11-aug09--10-----454000-------A
1-AUG-09----10----455.98----104A------30-sep-09--10-----430000------A
Br 11
10-aug-009--11----23245-----102a -------09-aug-09-11-----550000-------B
Br12
19-aug-09-12-----10000-------103B------09-aug-09----12-----550000-------Binto properly formatted expected output, along with a reasonable explanation of why
4. Turn this
select distinct null as refdt,null as refbr,null as refamt,null as refcat,b.trdt,b.brn,b.brtot,b.brcat
from brdet a,refdet b
where a.refbr (+) = b.brn
union all
select distinct a.refdt,a.refbr,a.refamt,a.refcat,null as trdt,null as brn,null as brtot,null as brcat
from brdet a,refdet b
where a.refbr = b.brn (+)into a properly formatted query
And last, put everything in into curly brackets {noformat}{noformat} to preserve formatting and blank space.
Best regards
Peter -
How can i sync my iphone to a new computer without restoring settings and deleting everything?
I've just gotten a new desktop computer and I'd love to have my iPhone synced to it...but I cannot do that without "restoring" settings or erasing my current library to sync to this new library. The problem is I have absolutely nothing on this new computer and I do not wish to delete anything on my phone... what's the best way to go about this without losing any of my notes, photos, contacts, apps etc? I accidentally restored my iphone last year and it was horrible trying to get everything back on it, I just don't really want to do that again! I'm thinking I could possibly back up to iCloud and then erase my current library and start from there, but I'm very paranoid about losing my contacts and my photos! Also I just visited the iCloud website and I couldn't figure out how to access my photos on there. Any help that anyone could offer would be awesome! Thank you!
https://discussions.apple.com/docs/DOC-3141
-
How to create Table in a Table without a ViewLink for Master/Detail
Hi,
Can we create a Table within Table in OA Page without using a view link. Need a Master Detail records to be displayed but I can't use a ViewLink. Is it possible to
have a Table within Table without using a ViewLink. As I have DetailVO with multiple bind variables. I tried ViewLink but it didn't work so wondering if can achieve this
using table in table without ViewLink
ThanksHi,
I created a Table then in the table I created a detail in which I created another table I created a transient view attribute i.e. DetailFlag that I set to my outer table. When I run the page it does show me the Master records and showhide link but when I click on the show it throws an error saying:
oracle.apps.fnd.framework.OAException: oracle.jbo.NoDefException: JBO-25002: Definition of type Attribute not found
Even though all the items in Detail table are attached to VO attributes of DetailVO
As I have a different MasterVO query with some bind variables and the DetailsVO query is different with some bind variables. Now how do I capture when a user clicks on Show and at that time wants to get some values from a selected master row and pass them to my DetailVO Query so the detail data for that selected master row shows. How do I get handle to the selected Row Data so to get the some values that need to be passed to the DetailVO.
I tried following the guide but am not able to have it functioning.
Here is what I have in my controller's processRequest method
OAApplicationModule am = pageContext.getApplicationModule(webBean);
System.out.println("******* 1");
am.invokeMethod("initializeTables");
OATableBean table =
(OATableBean)webBean.findChildRecursive("OuterTable");
if (table == null)
MessageToken[] tokens = { new MessageToken("OBJECT_NAME", "OuterTable") };
throw new OAException("AK", "FWK_TBX_OBJECT_NOT_FOUND", tokens);
table.queryData(pageContext, true);
System.out.println("******* 2");Any help is appreciated.
Thanks -
Visual Composer 7.0 : configuration & technical settings before delivery
Hi gurus,
Environment is NW2004S / EP 7.0 and back-end R/3 system release 4.6C.
I've been requested by developers to setup Visual Composer 7.0 as it is integrated in NW2004s.
As it seems that setup completed succesfully (i accessed to URL "http://<myservername>.<mydomainname>:<portnumber>/VC/default.jsp" and connected to visual composer interface, i 'd like to know if others technical settings are required before providing/delivering this development tool... as developers are currently quiet hard to please
I created a new model and composed succesfully.
However, I need to be sure that technical configration is proper.
Thanks for your experience feedback and help.
Rgds,
zulainIt seems to be an double post. Have a look to this thread for answering:
Visual Composer 7.0 : configuration & technical settings before delivery
Best Regards,
Marcel -
Adding a single table without a logical join to another table (OBIEE 10g)
Sometimes I want to just display a single table without a logical join to another table in the repository. However, everytime I move it to the Business Model and Mapping layer and perform a Global Consistency Check, it tells me that it needs a logical join and I am forced to create another table to join to it. Thus creating a dimension-fact relationship. There are times I don't need this relationship and just want to display some data. Is there anyway to get around this?
Thanks in advance!Yes,You have to create a join.You cannot take single table to BMM layer.You can create an alias of the table.Join this alias and base table through any common column and take both tables to BMM and desired table to presentation layer.
Another way is to create a view in physcial layer.Write a select statement like
Select primary_key from Table
Where primary_key is primary key of base table.Join this view ith base table and repeat the steps defined for Alias.
Regards,
Sandeep
Maybe you are looking for
-
Hi all, i saved a file in Pages, it saved as normal into My Documents, but how does it get on my iCloud ?, i was wanting to continue editing it on my iPad, on which i also have Pages, but i immediately came up against another problem, thinking i migh
-
What is the rule for adding application elements to faces-config.xml
I have posed this question before, but was unable to get an answer so here goes again. What is the rule for adding more than one application element to the faces-config.xml? The schema documents that 1-n are possible, but why and when should I do thi
-
Hi. I am making a TableView app here's my code : http://pastebin.com/myvW9ixk Is there anyway to change factsFile's (NSString) encoding ? Because the file that i download is in ISO Latin. Thanks, Senly Message was edited by: Senly
-
When I save my photos to a CD for storage, I usually drag the iphoto file folders to the CD. When I check the CD, the folders are gone, as well as the photo names. They are in a simple list, with the IMG.JPG designation. It is a huge amount of troubl
-
Case Study: Demo Database cannot be restarted - What to do
I just got a customer message 1424434 2008 where the MaxDB DB for a SAP demo installation. The database (MaxDB 7.5) won't start up anymore. 1. Problem description and analysis: In the knldiag file there are messages like this: 2008-03-02 23:44:16