Tablespace 88% full will impact performance?

Hi,
I have a tablespace with 10 datafile in a disk.The tablespaces id 88% full with 9 datafiles being 99% and 1 left with 10% .will this impact the performance.
or is it ok

There should be no performance impact, unless you are using the 10 data files to spread I/O for the tablespace across multiple disks, but it doesn't sound like that's the case here.
Justin

Similar Messages

  • Ultra 24 that will not perform POST

    I have an Ultra 24 that will not perform POST. I think the BIOS is corrupted or the motherboard went bad. All I get is the white Sun logo splash screen at poweron. The fan is running full speed too.
    Any ideas?

    So I took the iMac to the Apple store for service.  They confirmed my greatest fear...  Bad logic board.  The cost to replace this component was in the ball park of $700.  The techs at the Apple store provided daily communication as to the progress of their diagnosis.  In the end, I asked them to not do the repair and just button up the machine.  To my amazement, when I went to pick up the iMac they did not charge me a dime.  I then went and ordered a new 27" iMac online.

  • TABLESPACE ABOUT FULL(98 %)

    Our database having 7 tablespaces and one of the tablespace becoming full. OEM shows 98% and show free MB 172.8. Our applications is OLTP and having a lot of transactions , application running 24 hours in the day. I afraid, once table space becomng full(100 %), Our daily operations may be in problem. Will oracle will do automatically get the extents to acquire more spaces or I have to increase the tablespace by adding more datafiles or increase the exisinting datafiles. pls note that .. extent management : local, auto and segment managment : Auto. thanks.

    Hi,
    Did OEM generated alert? i think if autoextend is "on" and maxbytes set to large value, OEM handles it silently, it shows tablespace usage as 98%, but will not generate alert.
    If you want to monitor your production tablespaces, here is the script, consider the last column "MAX_PCT_USED" to identify current tablespace usage regardless autoextend status (ON/OFF).
    set linesize 300;
    SELECT a.tablespace_name TBS_NAME, ROUND (a.bytes_alloc / 1024 / 1024, 0) MEGS_ALLOC,
    ROUND (NVL (b.bytes_free, 0) / 1024 / 1024, 0) MEGS_FREE,
    ROUND ((a.bytes_alloc - NVL (b.bytes_free, 0)) / 1024 / 1024,0) MEGS_USED,
    ROUND ((NVL (b.bytes_free, 0) / a.bytes_alloc) * 100, 2) PCT_FREE,
    100 - ROUND ((NVL (b.bytes_free, 0) / a.bytes_alloc) * 100, 2) PCT_USED,
    ROUND (maxbytes / 1048576, 2) MAX_MEGS_ALLOC,
    100 - ROUND ((a.bytes_alloc - NVL (b.bytes_free, 0)) / maxbytes * 100, 2) MAX_PCT_FREE,
    ROUND ((a.bytes_alloc - NVL (b.bytes_free, 0)) / maxbytes * 100, 2) MAX_PCT_USED
    FROM (SELECT f.tablespace_name, SUM (f.BYTES) bytes_alloc,
    SUM (DECODE (f.autoextensible,'YES',f.maxbytes,'NO', f.BYTES)) maxbytes
    FROM dba_data_files f
    GROUP BY tablespace_name) a,
    (SELECT f.tablespace_name, SUM (f.BYTES) bytes_free
    FROM dba_free_space f
    GROUP BY tablespace_name) b
    WHERE a.tablespace_name = b.tablespace_name(+)
    Regards,
    Vineeth
    Edited by: Vineeth Kalanthodi on Jan 31, 2010 9:04 PM

  • Will there performance improvement over separate tables vs single table with multiple partitions?

    Will there performance improvement over separate tables vs single table with multiple partitions? Is advisable to have separate tables than having a single big table with partitions? Can we expect same performance having single big table with partitions? What is the recommendation approach in HANA?

    Suren,
    first off a friendly reminder: SCN is a public forum and for you as an SAP employee there are multiple internal forums/communities/JAM groups available. You may want to consider this.
    Concerning your question:
    You didn't tell us what you want to do with your table or your set of tables.
    As tables are not only storage units but usually bear semantics - read: if data is stored in one table it means something else than the same data in a different table - partitioned tables cannot simply be substituted by multiple tables.
    Looked at it on a storage technology level, table partitions are practically the same as tables. Each partition has got its own delta store & can be loaded and displaced to/from memory independent from the others.
    Generally speaking there shouldn't be too many performance differences between a partitioned table and multiple tables.
    However, when dealing with partitioned tables, the additional step of determining the partition to work on is always required. If computing the result of the partitioning function takes a major share in your total runtime (which is unlikely) then partitioned tables could have a negative performance impact.
    Having said this: as with all performance related questions, to get a conclusive answer you need to measure the times required for both alternatives.
    - Lars

  • If my SSD on my Air is almost full, will it slow down the computer?

    If my SSD on my Air is almost full, will it slow down the computer? As in, if I have about 20GB left on my SSD, will the computer run slower?

    Rule of thumb tends to be that you should set aside 10% of disk space for SSDs for the best speed. This comes from SSDs in Windows PCs, where the SSDs do perform more slowly when full rather than having some free space. This is just how SSDs work, which I won't get into the technicalities of. The SSD controllers themselves allocate set a reserve space (this could not be true in Apple's case, depending on what chips they use), but generally the more free space the better. So 64GB should set aside 6GB, 128GB should set aside 12GB, and 256GB should set aside 25-26GB.
    SSDs technically will never be as fast as when you first got it. They slow down as soon as you start to write data to them, but the slowdown will be negligible. It's still faster than a HDD at the end of the day.

  • TEMP tablespace getting full while inserting a CLOB in Trigger

    We have a Oracle 10g (10.2.0.4.0) DB on a Solaris 9 box which also runs our J2EE web-service application on Weblogic 8sp6 server.
    We get around 220K web-service requests from upstream callers daily to insert data in the main table, say TABLE1, which has daily partitions on a date column. This table has around 21 columns out of which 1 is a CLOB column.
    Now this table has an AFTER INSERT trigger which calls a package procedure to insert the same record into another table, say TABLE2.
    From Java application insert statement in executed in below format using a weblogic jdbc connection pool :
    INSERT INTO TABLE1(COLUMN1, COLUMN2, ........., CLOB_COLUMN,........, COLUMN21) VALUES (:1, :2, :3, :4, :5, :6, :7, :8, :9, :10, :11, :12, :13, :14, :15, :16, :17, :18, :19, :20);
    Clob object is prepared in application using ojdbc14.jar.
    We are observing a strange issue here. The TEMP tablespace utilization keeps on growing as more and more inserts are executed by application and after ~125K inserts the TEMP tablespace gets full and we start getting ORA-01652 error.
    On further analysis we could see that there are only 7-10 session being maintained but as more and more inserts happen TEMP tablespace utilization goes on increasing for each of these sessions.
    When we tried with inserting just few records and then watching the session details in v$session_wait then we could see that it is in INACTIVE state and waiting for the event ‘SQL*Net message from client’. This does not seem correct as the session has successfully inserted the data and committed the transaction and we can see the data in the tables as well.
    The confusing thing here is when we modify the trigger to pass blank string('' ) instead of the CLOB column to TABLE2 then this issue does not occur. All 200K records are inserted properly and TEMP tablespace utilization also keep always below 1%.
    Can you please help us in solving this issue. Is this related to any oracle issue?
    Inside the package we have tried using DBMS_COPY statement to copy the CLOB column after insert but still same result.
    Code for reference:
    Trigger:
    =====================================
    CREATE OR REPLACE TRIGGER trg
    AFTER INSERT OR UPDATE
    ON TABLE1
    REFERENCING NEW AS NEW OLD AS OLD
    FOR EACH ROW
    BEGIN
    IF (:NEW.date_col > SYSDATE - 2)
    THEN
    IF (:NEW.cat IN (1001, 1002))
    THEN
    pkg.process_change
         (:NEW.COLUMN1,
              :NEW.COLUMN2,
              :NEW.CLOB_COLUMN,
    FLAG
    END IF;
    END IF;
    END;
    =====================================
    Package:
    =====================================
    procedure PKG.Process_change(
    p_COLUMN1 number,
    p_COLUMN2 varchar2,
    p_CLOB_COLUMN clob,
    flag boolean
    ) is
    v_watermark pls_integer;
    v_type varchar2(1);
    begin
    if (flag) then
    v_type := 'U';
    else
    v_type := 'I';
    end if;
    select t_seq.nextval into v_watermark from dual;
    insert into TABLE2(
    COLUMN1 number,
    COLUMN2 varchar2,
    CLOB_COLUMN clob,
    watermark,
    dml_type
    )values (
    p_COLUMN1 number,
    p_COLUMN2 varchar2,
    p_CLOB_COLUMN clob,
    v_watermark,
    v_dml_type
    end;
    =====================================

    My first thought on reading your post is that not only are you using a database version that is now so old it is in extended support and even then not even the most recent patchset for it.
    The first thing I would do is move to 11gR2 and if you can't do that at least get to 10.2.0.5 and apply CLOB relevant patches as well.
    Same goes for your operating system. Solaris 9 is ancient: So move to 10 which has vastly improved memory management.
    To help you further it would be really valuable to know the table layout. For example is this a heap table or an IOT? Is it partitioned? Is this RAC? What size are the CLOBs? Are they stored in-line? Chunk size? etc.
    This page should start you down the right road:
    http://docs.oracle.com/cd/B19306_01/appdev.102/b14249/adlob_tables.htm#sthref204
    But I am also wondering why you would use a trigger to, as you say, "insert the same record into another table." This description is a poster child for "bad design."

  • Order types entered in a Ztable, system will not perform material listing.

    Hi Guys,
    I have a requirement where user will enter the list of order types to be excluded from material listing  through a custom table.
    For all those order types entered in the custom table the  system will not perform any material listing check, regardless if the material is existing in the material listing.
    Can you please tell me how to do this through coding???Any particular exit or where can i code this.???
    Many Thanks in Advance,
    Rajendra
    Moderator message : Requirements dumping not allowed, show the work you have already done.  Thread locked.
    Edited by: Vinod Kumar on Jan 13, 2012 4:08 PM

    Swagat,
          Thank you for your response, what I am still not getting is - even in manual transfers via LT10 shouldn't the system restrict the movements to certain storage types? If you think from the shopfloor perspective the WM material movements are done at WM level only - meaning moving materials from one storage type to another and LT10 is widely used as it is one step tcode.
    I know we can restrict movements when storage class is assigned in search strategy, but this applies only to hazardous materials. The material in question is not hazardous so I am still thinking if there is any way to restrict material movements.
    Do you have any documentation link which mentions search strategies are not taken into consideration during manual transfer? If yes please send that would be helpful.
    Once again thanks for your time.

  • No entered status set. No results analysis will be performed

    Hi Guys,
    I keep on getting this error message beloe and the valuation is on RELEASE status
    No entered status set. No results analysis will be performed
    Message no. KJ210
    Diagnosis
    The valuation of the order or project in results analysis depends on the status of the object.
    In this case, the object does not have an active status entered in the valuation methods in Customizing for WIP calculation and results analysis. Consequently, WIP calculation and results analysis cannot find a method with which the object can be processed.
    Procedure
    Decide whether the object should be processed in its current state (indicated by its active status in status management) by WIP calculation and results analysis.
    If you want to process the object:
    In Customizing for results analysis, choose Period-End Closing -> Results Analysis -> Define Valuation Methods for Results Analysis, add an entry for this status, and specify how objects with this status should be processed.
    If you do not want to process the object:
    This message is inconsequential for you. No follow-up actions are necessary.
    In Customizing for results analysis, choose Period-End Closing -> Results Analysis -> Define Valuation Methods for Results Analysis and select the No valuation indicator. This message is then no longer issued by the system.
    Example:
    In the standard system, there is normally no entry in the valuation method for the status CRTD (Created). You will therefore receive this message for objects that only have the status CRTD.

    Hi Guys,
    I manage to run the RA. The problem why I could'nt get it right was because I did not run transaction MMPV to close period for material master
    Thanks for your help.

  • Tablespace 85% full

    Hi,
    I see a 'Tablespace 85% full' warning in EM. I looked through the tablespace stats and found it has datafiles that are autoextensible and have a maxbyte number set to 1GB.
    Does that mean that the datafiles are autoextensible only till the datafiles reach 1GB?
    Thanks.

    Does that mean that the datafiles are autoextensible only till the datafiles reach 1GB?yes
      1* select tablespace_name, autoextensible, round(maxbytes/(1024*1024)) MB from dba_data_files
    SQL> /
    TABLESPACE_NAME             AUT        MB
    USERS                      YES     32768
    SYSAUX                      YES     32768
    UNDOTBS1                 YES     32768
    SYSTEM                      YES     32768
    EXAMPLE                  YES     32768

  • FTP proxy will impact all WLS server

    Hi everybody.
    I try to use proxy to FTP. But when I set the socksProxyPort, socksProxyHost. This
    will impact all WLS instance. It seems due to use System.getProperties().put().
    How can I use the local setting for proxy.
    My code looks like this:
    System.getProperties().put( "socksProxyPort", "1080");
    System.getProperties().put( "socksProxyHost" ,"ftp-proxy");
    Authenticator.setDefault(
    new Authenticator() {
    protected PasswordAuthentication getPasswordAuthentication() {
    return new PasswordAuthentication("p_ebo_ldt_ftp1","opcftp123".toCharArray());
    );

    If what Tim has suggested doesn't help, you could try to use a Proxy Automatic Configuration file. It may help forward certain protocols to use the proxy. You can find more information about PAC files here: http://en.wikipedia.org/wiki/Proxy_auto-config
    Here is an example we use:
    function FindProxyForURL(url, host) {
    // If IP address is internal or hostname resolves to internal IP, send direct.
    var resolved_ip = dnsResolve(host);
    if (isInNet(resolved_ip, "10.1.0.0", "255.255.0.0"))
    return "DIRECT";
    else
    return "PROXY 127.0.0.2:80";
    I've changed the IP address values to protect the privacy of where I am employed

  • Mouse will not perform click and drag

    My Magic Mouse will not perform click-and-drag function anymore after Mavericks.

    Problem solved thanks to Eric Cote:
    https://discussions.apple.com/message/15696875#15696875:
    "you may want to trash your preference files under:
    Users/<your user name>/Library/Preferences/com.apple.driver.AppleHIDMouse.plist
    then reset the mouse prefs"
    Thank you Eric!

  • If MTU size will increase in cisco 3550 does it will impact any traffic ?

    For WiFi traffic from source to destination MTU size should ping up to 1472 Now the MTU is pinging up to 1468 because port level MTU size is 1500 we need to increase 1522.
    while we changing size it will impact my traffic ?
    Model number: WS-C3550-24-DC-SMI
    #sh version
    Cisco IOS Software, C3550 Software (C3550-IPSERVICESK9-M), Version 12.2(25)SEE4, RELEASE SOFTWARE (fc1).
    Any suggestions on this.
    Thanks in advance.
    NagaPrasad

    Hello Prasad,
    Changing the MTU size in general will not cause any impact except if it is VPC domain.
    But it is advisible that MTU size keep same at both ends.
    FYI...
    Changing the MTU value (with the mtu interface configuration command) can affect the IP MTU value. If the current IP MTU value is the same as the MTU value, and you change the MTU value, the IP MTU value will be modified automatically to match the new MTU. However, the reverse is not true; changing the IP MTU value has no effect on the value for the mtu command.
    Please rate the helpfull posts.
    Regards,
    Naidu.

  • I need to create a schedule that will be performed every day

    Hi,
    I need to create a schedule that will be performed every day. Must start at a specified time and finish their work at a certain time. Joby hooked to this schedule must do their work in a loop, until he completed the work to the procedure. Do you have any solution?

    6e4e5455-0183-4163-be68-1e68fc529042 wrote:
    Hi,
    I need to create a schedule that will be performed every day. Must start at a specified time [...]
    Easy, use DBMS_SCHEDULER to schedule the job to start at a particular time every day.
    [...] and finish their work at a certain time. [...]
    What should it do if it finishes early? What should it do if it hasn't finished its work by the given time? There may be things you can do to make it crash out at a given time - but its helpful to know what your aims are first.
    Joby hooked to this schedule must do their work in a loop, until he completed the work to the procedure. Do you have any solution?
    I don't have a clue what that last sentence means, let alone a solution.

  • HT4847 If my iCloud storage is almost full will The items I purchase still be stored in iCloud and will I still have access to these items?

    If my iCloud storage is almost full will my purchases still be available there and be accessible?

    Purchases made do not count towards your storage limit.  They are always available.

  • My Time Machine will not perform a back up!!! Can someone help?

    I have recently bought a ne IMAc 27inch have been able to transfer all my data from the old iMac24", which is a lot and now my new Time Capsule with 2T of HD will not perform backup.  Every time i try to set up TM I get the following message:
    I have reserched on Apple forums and have found soluions such as restart the TC, turn it on and off several times, erasing the TC though AirPort Utility (which, by the way has taken over 8 hours), so I am desperate now!
    Can someone help?
    My new computer has two HD one SSD and one Analog, it's a brand new iMac.

    My new computer has two HD one SSD and one Analog, it's a brand new iMac.
    The "Analog" disk; it is mechanical with platters which are entirely digital.
    Did you name both disks the same?
    If so rename a disk.. that is what the error message says.. you cannot have two identically named disks.

Maybe you are looking for

  • IPod touch 5 lag issue running iOS 8.1 ( PLEASE RESOLVE THIS ASAP)

    OMG, i'm just fed up of using this iPod 5 after this new update of apple's iOS 8.1.  I did checkout iOS 8.1.1 but as it bought no changes to the performance i just downgraded it back to iOS 8.1. Well performance really matters on a device. The day i

  • FileReference upload failure

    Hi, I got a FileRefrence instance for a simple upload and it did work for some time in the past, but now I just can't discover what made it stop woking. Can anyone help me find it out? To simplify, I took only the necessary code (not working as the f

  • In built microphone not working.

    Hi - I have an iMac OS X Version 10.6.8 bought in April 2008.  I'm attempting to record a voice over in iMovie - however the inbuilt microphone isn't working (it doesn't work with Skype as well)  Is there any way to do a diagnostic test? Thanks

  • If i download iOS 8 on my computer, can I unplug my phone without disrupting the download?

    I am downloading iOS 8 on my Itunes and my phone is plugged in. I can't leave my phone at home for 3 hours while it downloads. Can i remove my phone and still have iOS 8 download?

  • TestStand not updating th descriptio​n after using the edit substep

    I've created numerous custom steps in TestStand.  None of them will update the description after I use the edit substep and change some of that steps properties.  As an example, I have the following step description... str(Step.Channel.DeviceName) Af