Timeout setting for Conntrans?

Hi,
We had some issues in regards to timeouts when Conntrans ran on some mobile clients. The reason seemed to be related to huge BDoc size and the TRFCQOUT table not being organized on a frequent basis. We have now reduced the BDoc size of some messages as well as scheduled a weekly reorg on the outbound queue tables. However, is there something related which handles a timeout setting? For instance I can see that a timeout occurs after 700 seconds, can you extend this or is just plain because of performance? If it exist, where can you set this (is it on DB level)?
Thanks,
Sebastiaan.

Hi,
Timeout during receive phase of Conntrans can happen, either because the Bdocs are huge or if Conntrans tries to receive a lot of messages in a single go.
To Resolve the problem please to the following:
1.Assign a lower value for the MAX_PACKAGE_SIZE parameter for this Bdoc in trnx: r3ac6.
If you still face a timeout after reducing the Bdoc size, the number of Bdocs Conntrans receives in a singlr shot needs to be restrained.
For that do the following.
If you are running CRM 5.0 Mobile Application, set\create the registry key NumMsgToPull at HKEY_LOCAL_MACHINE\Software\MSA\NewTransferService to any low value(below 5).If this key is set to zero, Conntrans will try to receive 20 messages at a time and may time out if the messages are large.
If you are running CRM 5.0 Mobile Application or CRM 4.0 XML Data Transfer, set\create the registry key NumMsgToPull at HKEY_LOCAL_MACHINE\Software\MSA\NewTransferService to any low value(below 5).If this key is set to zero, Conntrans will try to receive 20 messages at a time and may time out if the messages are large.
If you are running CRM 4.0 Mobile Application  set\create the DWORD TranferRate at HKEY_LOCAL_MACHINE\Software\MSA\TransferService to any low value(below 5).If this key is set to zero, Conntrans will try to receive 20 messages at a time and may time out if the messages are large.
Regards,
Shourav

Similar Messages

  • Timeout setting for Realtime-Sequence execution

    Hello,
    I'm referring to the "Timeout" setting in the stimulus profile editor or the "Timeout" parameter of the SequenceCallInfo Constructor. The description of this parameter is as follows:
    The timeout in milliseconds within which the sequence must complete each time step.
    What exactly is this parameter good for? I understand that each task in a realtime sequence is executed once per PCL iteration and that the "time step" of a task is completed when the control flow reaches a "Yield" statement (or the end of a loop with autoyield enabled).
    When I'm running a sequence where a timestep takes longer than the PCL period, the VeriStand engine will abort and undeploy the system definition. In my case the PCL rate is 2KHz so isn't the timeout implicitly given as 500us?
    I thought that maybe I can use the timeout parameter to set an additional timeconstraint from "greater 0 to less than PCL period". So for example if I set it to 0,1ms, the realtime sequence would have to hit a Yield statement within 100us. But this doesn't seem to be the case either because the realtime sequence is not aborted and it still stops the VeriStand engine.
    Thanks
    Krid

    Hi Jarrod,
    thanks for your answer but your second use case is exactly what I tried to do. The VeriStand engine is still aborted even when I run the sequence with timeout set to 0,01:
    Error -307743 occurred at NI VeriStand Engine.lvlib:VeriStand Engine Wrapper (RT).vi >> NI VeriStand Engine.lvlib:VeriStand Engine.vi >> NI VeriStand Engine.lvlib:VeriStand Engine State Machine.vi >> HP Loop.lvlib:HP Loop Main.vi
    I just tested it again and the first time I started the stimulus profile, the realtime sequence actually was aborted and the VeriStand engine continued to run. Then I started the stimulus profile a second time (without changing anything) and this time the profile was not aborted and hence  the VeriStand engine was stopped. It's also not possible to stop the profile in stimulus profile editor. It just hangs and I have to kill it.
    After this happened it's also not possible to run any other realtime sequences (they will simply not start but no error message is returned).  One has to completely close down VeriStand (just re-deploying doesn't work) and restart it before it works again.
    Why isn't the timeout parameter working as it's supposed to?
    Regards
    Krid

  • Is there a way to change the timeout setting for iCal / Calendar in 10.8?

    I have a user connected via iCal to an overworked old CalDAV server (running OS X Server 10.5.8) who was doing fine in OS X 10.6.8. The data (from a number of groups, and his own individual calendar) would sometimes take a while to refresh, but it always came down eventually.
    Once he upgraded to 10.8.1, his calendars would often have exclamation points next to them saying they couldn't connect. Manually refreshing would add "Updating..." to the title of the calendar window, but most of the time, the exclamation points would come back. I did some testing with LittleSnitch, and found that, if Calendar didn't hear back from the server for 30 seconds, it would time out.
    Using the same CalDAV account on another machine with iCal in 10.6.8, connecting to the same server, it goes past 30 seconds and keeps going. (Maybe the default setting is 60 seconds; I haven't seen it triggered.)
    Does anyone know if there's a way to tell Calendar in 10.8.1 to wait a little longer before timing out?

    It appears that the previous user purchased the Server app through his or her own App Store account. You would need to know that account ID and password to update that or any other app purchased through that account. If you are unable to get that account information, you will have to delete the app from your system and re-purchase it through an App Store account you can use. There is no way to transfer an app from one App Store account to another.
    Regards.

  • Where to find the timeout setting for connecting to SAP Bi Universe in Power Query for Excel

    Hi All,
    I am trying to connect a SAP BI Universe. I am able to login to the environment and get the list of folders. But on trying to use the universe inside the folder, I am getting a time out error. The time out happens exactly at 100 seconds always.
    DataSource.Error: SapBusinessObjects: The operation has timed out
    Can you let me know if any setting can be done to avoid this timeout and get the universe into power query?

    I have the same problem with Version: 2.17.3850.242. It times out after 100 seconds. 
    In addition, I couldn't report it by sending a frown. Get the following error message
    Error Message: Could not load file or assembly 'Microsoft.Office.Interop.Outlook, Version=14.0.0.0, Culture=neutral, PublicKeyToken=71e9bce111e9429c'
    or one of its dependencies. The system cannot find the file specified.

  • Longer timeout setting for universe object descriptions popup tooltip

    When building a report using the Java Report panel, if I hover my mouse over a universe object the description will appear in a popup tooltip-style box.  However, the description only displays for five seconds, which is not enough time to read the whole description.
    How can I make the popup tooltip display for 15 seconds?

    The answer I got from Business Objects is that the timeout is part of the .jar file and cannot be changed.

  • New-WebServiceProxy timeout setting?

    Hi,
    Is there a way to increase the timeout setting for new-webserviceproxy? I am calling a webservice that takes a some time and my powershell script times out "New-WebServiceproxy : The operation has timed out"
    Thanks

    Hi,
    Change the intellisense timeout value from the default 3 seconds to a greater value.
    To do this, click Tools, and then click Options. On the General Settings tab, in the Intellisense section of the form, click the drop-down list to
    change the Intellisense timeout in seconds value. 
    This works for Windows PowerShell 3.0 ISE. Please try it also with your own powershell.
    In addition, hope the below link be helpful:
    BUG: You receive a "The operation has timed-out" error message when you access a Web service or when you use the IPAddress class
    http://support.microsoft.com/kb/815209
    Regards,
    Yan Li
    Yan Li
    TechNet Community Support

  • Timeout setting in registry?

    when I run "c:\openfiles /query -v" command on Windows 2003 server the Files opened remotely via local share points: shows an open file handle and then after some time (like a minute or less) it disappears. I assume it timed out due to inactivity
    or something. Is there a timeout setting for this defined somewhere in the registry?
    I wanted to expand on this:
    The problem is when the user downloads a file over the web the file is placed in a shared folder on the file server and then served to the client's browser.  The client gets a Download File dialog in Internet Explorer. If they are idle for more than
    a minute before saving or opening the file, they get an error like "Internet Explorer cannot download. the server returned an invalid or unrecognized response"
    Thanks

    Hi,
    From your description, it seems you are trying to download files from your web server, I am not similar with the IIS, but I found some SMB idle timeout settings maybe can
    give you some tips.
    SMB 2.x and SMB 3.0 Timeouts in Windows
    http://blogs.msdn.com/b/openspecification/archive/2013/03/27/smb-2-x-and-smb-3-0-timeouts-in-windows.aspx
    More about the IIS question please post to the IIS forum.
    IIS support forum
    http://forums.iis.net/
    Thanks for your understanding and support
    We
    are trying to better understand customer views on social support experience, so your participation in this
    interview project would be greatly appreciated if you have time.
    Thanks for helping make community forums a great place.

  • Setting timeout option for GIT in TFS 2013 update 4

    Hi all,
    I want to increase the timeout option for GIT but I do not know how to set it.
    Please help with how can I set the timeout value for GIT. I am getting "Timeout Error" whenever I am trying to run the 'git pull' command. The repository size is in GB and its taking time to complete the action and during this process 'Timeout'
    occurs.
    Please help me.
    Thanks,

    Hi Vaibhav,
    I do not believe there is a straightforward way to achieve this since stakeholder is replacing limited access. I think you may have to raise User Voice here https://visualstudio.uservoice.com/forums/121579-visual-studio/category/30925-team-foundation-server 
    Cheers!
    Chaminda

  • Setting timeout settings for Action Scripts

    We are using OIM 11gR1 along with the AD and Domino connectors. We are also using Action Scripts to perform some post create actions on the AD and Domino resources that get created by OIM. The action scripts are being invoked with the correct set of parameters and they do their job. However for both connectors, the connector server (Java connector server for Domino, .NET connector server for AD) times out when waiting for the script to complete. Our scripts are expected to take a long time (30+ seconds).
    Based on our testing, the AD connector times out in 30 seconds, and the Domino connector times out in 20 seconds. You would get the below exception in your Java Connector Server log file:
    Dec 4, 2013 2:36:41 PM org.identityconnectors.framework.api.operations.ScriptOnConnectorApiOp runScriptOnConnector
    FINE: Exception:
    java.lang.RuntimeException: Timeout waiting for action, process was terminated
        at org.identityconnectors.domino.WinJni._executeWinCommand(Native Method)
        at org.identityconnectors.domino.WinJni.executeWinCommand(WinJni.java:31)
        at org.identityconnectors.domino.ScriptOnConnector.executeCmdScript(ScriptOnConnector.java:143)
        at org.identityconnectors.domino.ScriptOnConnector.runScriptOnConnector(ScriptOnConnector.java:88)
        at org.identityconnectors.domino.DominoConnector.runScriptOnConnector(DominoConnector.java:316)
    Is there any way to configure OIM so that it waits longer for the action script to complete. The real problem over here is that if 2 users are being provisioned to AD and/or Domino simultaneously (we use access policies to trigger provisioning rules), then the connector (Java or .NET) does NOT invoke the action script for the second user if the action script for the first user times out. It does however create AD/Domino resources for all applicable users. This in itself is a defect - but I need a workaround.
    Looking at some old Sun Identity Manager documentation (which became Oracle Waveset), it seems that the entire OIM concept of action scripts has its origins in Sun Identity Manager/Oracle Waveset. And these products did support the notion of timeouts. Have a look at :
    http://docs.oracle.com/cd/E19225-01/821-0092/bzbuc/index.html
    Does anyone familiar with Oracle OIM code know if custom timeouts are supported by AD and Domino connectors?
    Thanks
    Aspi Engineer

    Change the time for the below under 'Web Intelligence Processing Server'
    Idle Document Timeout (seconds):
    Idle Connection Timeout (minutes):
    If you still have problem then try changing the web.xml under the following war files,
    AdminTools
    PartnerPlatformService
    PerformanceManagement
    PlatformServices

  • Keep alive TCP setting for port 3998 to avoid fw timeout?

    Hello,
    in our new DS6.1 env, replication between the master DS is using port 3998 through several firewalls. If there are no changes to the DB (we are still testing), the connection seems to time out on the firewall and the status of the remote masters in the SMC drops to "stopped" even though they are still running. If one clicks on the DS entry in the SMC, it seems to set up a fresh TCP connection and the status is ok again.
    Is there a way to define a keep-alive setting for these connections ?
    TIA,
    heinz

    DS 6.3 has bug 5087249 against it for the missing SO_KEEPALIVE socket option.
    This bug was fixed a long time ago in the DS 5.x series which got "unfortunately lost" on the way
    to the 6.x release :-(
    If you have a valid Sun Support contract you can request a hotfix for this bug 5087249 in
    DS 6.3 (or the soon to be released 6.3.1), by raising a support service request.
    A similar missing SO_KEEPALIVE socket option bug exists in the DPS 6.3 server,
    bug 6782659 is open against this and if you have a valid Sun Support contract you can
    request a hotfix for this bug 6782659 in DPS 6.3 (or the soon to be released 6.3.1).
    Without a valid support contract, I'm afraid you'll have to wait until the next official patch
    release of both these servers (DPS & DS) after the 6.3.1 which does not contain these 2 fixes.
    This will most probably be at least one year into the future from present.
    The problem with CLOSE_WAITs DPS issue is fixed in the same hotfix for bug 6782659 (which
    contains many connection handling bug fixes/enhancement in addition).
    Hope this helps.

  • Xl Reporter Timeout Setting

    Hi All
    We have the following message when trying to generate a large report in XL Reporter. 
    An error occurred while Executing report!
    Decription: Rows 2358, Column 244
    Timeout expired
    This is a very large report and it times out before it completes.  This message comes up after approximately 20 minutes of running.
    Please can anyone advise asap if they are aware of a timeout setting that can be extended in XL Reporter. 
    Alternatively is there a fixed limitation in the number of rows or the time a report is allowed to run?
    Kind regards
    Sam Burchell

    Hi Sam Burchell,
    When XLR builts report, it need both disk space and memories. For such large report, I doubt you have anyway to run. You need to redesign the report or add parameter to restrict the data range.
    For a report with over 200 columns, how would user read it?
    You can calculate by yourself: 2358 X 244 (cells) is probably the limit for this specific environment
    Thanks,
    Gordon

  • How to determine the timeout setting?

    I read all the items about the time out. I created a javascript function which informs you that you only have 5 (after that 1) minutes before logout. But in the profile file the setting for http timeout 180 and the rz11 setting icm/keep_alive_timeout is set to 60. But when waitng for 180 seconds I can still go on with the application. No timeout occur.
    How can I determine the real timeout so I can use this in the setting for the Javascript (reading it for the system and concatenate into the javascript statement)!
    With regards,
    Frank Roels

    Hai Frank,
    You can follow the methodology described by thomas in this blog.
    https://www.sdn.sap.com/sdn/weblogs.sdn?blog=/pub/wlg/1063. [original link is broken] [original link is broken] [original link is broken] [original link is broken] [original link is broken] [original link is broken] [original link is broken] [original link is broken] [original link is broken]
    When I have opened this blog now it was not opened properly(Formating lost),Make sure that u read it properly.
    Regard,
    venkatesh.

  • Help with flex4unit ant build.xml: Socket timeout waiting for flexunit report

    I'm having trouble setting up ant to build and test my project locally and I'm not sure what the next step is.
    Info:
    Running on XP/Cygwin.
    All of the files that FlexUnit4 references when used in Flash Builder are in my '${basename}/libs' folder (eg FlexUnit4_1.0.swc).
    I've placed the flexunit4 task in my ant/libs folder.
    I'm getting two errors...
    I don't think I've set up the 'socket' stuff right for the tests. It just sits and waits then dies...
    [flexunit] Waiting for client connection ...
    (about a minute later)
    [flexunit] Stopping server ...
    [flexunit] End of test data reached, sending acknowledgement to player ...
    [flexunit] Closing client connection ...
    [flexunit] Closing server on port [1024] ...
    BUILD FAILED
    java.util.concurrent.ExecutionException: Socket timeout waiting for flexunit report
    Plus this is the error I get from the flash player:
    ReferenceError: Error #1065: Variable mx.skins.spark::BorderSkin is not defined.
    I don't know why it's complaining about Borderskin as I think I have included all the flex4 libs I could find. I suspect this second error is causing the first error?
    Any help appreciated. I think I'm just setting it up all wrong.
    Screencap of errors:
    http://twitpic.com/l7ay8
    build.xml:
    http://gist.github.com/20804

    Finally got everything working using the files from the CI Example which what i probably should have done in the first place.
    So a rough guide for anyone just starting out with this:
    Download the Flex 4 'workspace' from the digital primates hudson server . This appears to contain flexunit library and examples in various stages of development.
    I used Flex Builder 4 Beta 2 to set up my Test Suite and Test Cases.
    I then loaded the libs folder from:
    workspace.zip\workspace\project\FlexUnit4SampleCIProject
    into my flex project's libs folder:
    this includes:
    FlexUnit4.swc
    FlexUnit4CIListener.swc
    flexUnit4UIRunner.swc
    flexTasks.jar
    flexUnitTasks.jar
    I didn't need to remove the FlexUnit4 stuff that is 'referenced' automatically by flash builder when you start adding flexunit4 tests/suites.
    Then I used a modified version of the TestRunner.mxml found in:
    workspace.zip\workspace\project\FlexUnit4SampleCIProject\src\test\flex
    The lines to pay attention to are the ones that look like:
    static public function currentRunTestSuite():Array {
        var testsToRun:Array = new Array();
        testsToRun.push(packagename.TestSuiteName);
        testsToRun.push(packagename.TestClassName);
        return testsToRun;
    Just make sure you update this list to include all of the test suites &/or individual tests you want to run.
    I made this a static function and modified the code in the "FlexUnitApplication.mxml" file to use this function so i'd only need to update one list of suites/tests.
    FlexUnitApplication.mxml is generated automatically when you run FlexUnit4 tests in the Flash Builder 4 Beta 2 IDE.
    This is the build.xml file I'm using in the project:
    http://gist.github.com/208211
    Change the name of the project from "Flare" to whatever and adjust the other path settings where required (though you might want to write this from scratch at least once so you understand roughly what is going on).
    The Debug Flash Player must be installed on the server otherwise you'll get a:
    java.util.concurrent.ExecutionException: Socket timeout waiting for flexunit report
    ...while it waits for the non-existant debugger to attach. (This is obvious but I did forget and was a bit bewildered for a moment)
    Need to also ensure the environment variable:FLEX_HOME is set to the location you installed the flex sdk...by editing your .bashrc setting the environment variable the in the Hudson Configuration.
    You'll need to point Hudson at your ant installation and your jdk installation. If you downloaded he sdk, be aware you might need to point it to the jdk folder inside the place you installed the sdk.
    And I think that's all the problems I had. Hope it's useful to someone... if anyone who actually knows what they are doing can point out any potential issues/better ways of doing things, feel free to comment.
    Thanks to Brian (legrosb) and Mike (mlabriola) for their assistance!

  • Samplerate problem using Analog In and Counter In from a NI 6259 USB. "Counter timeout" setting in DAQmx?!

    Hello,
    I got a fundamental problem with the correlation of the timer settings of the DAQmx driver in DIAdem DAQ. I dont know where the problem is located exactly but maybe someone can help me if I explain what happens:
    In my configuration I use some analog inputs from a USB 6259 with 20kHz samplerate and two counter inputs for frequency measuring via DAQmx in DIAdem DAQ.
    There has to be an extra DAQin block for the analog inputs and the counter inputs with also an extra "Clock"-block for each of them. The clock of the analog inputs runs with 20kHz hardware clock and the other one with 10Hz software clock because the hardware clock mode is not allowed or supported.
    My problem is the display refresh rate in VIEW. If the counter signal has no input (because the measured system is not active) the display seems to wait for any input and doesnt refresh the analog values on screen. If the system is active and a rectangle signal is seen by the counter in, the display refresh rate raises and the frequency value is displayed more or less accurate. Has that something to do with the counter timeout setting in the DAQin driver options block (marked in the attached image)? If i decrease the timeout, the display refresh rate gets better but not as good as without using the counter inputs in my DAQ diagram. I think the counter input is not as easy to handle as the usual analog inputs... I only want to see the measured frequency on the display during the measurement without getting any influence on the analog input channels and their displaying.
    The other problem is the display and the measurement of the frequency itself. If i check the function of the counter input in the Meas. & Automation Explorer the frequency is display correct without any dropouts or something like that. The signal I measure in DIAdem on the other side looks quite bad because there are spikes of some MHz and even more although the measured range is between 20 and 80Hz!
    Has anybody made similar experiences?
    Regards
    S. Zimmer
    Attachments:
    probs.png ‏112 KB

    Hi there,
    it seems that german is your mothertongue, so I'll reply on german.
    Digitale Eingänge müssen Software getaktet werden, da nur analoge Eingänge Hardware-Takt Unterstützung haben!
    Sie können den Hardware-Takt nur mit analogen Eingängen einsetzen, die, von einem Timer gesteuert, gepuffert Werte einlesen können. Digitale Größen verarbeitet der Hardware-Takt nicht.
    Mit dem Hardware-Takt erreichen Sie sehr hohe Abtastraten. DIAdem überträgt die gewünschte Rate und die Kanalliste auf die Karte und startet die Messung. Die Hardware erfasst die Daten selbstständig und sammelt die Daten. Der PC ist nur für den Abtransport und die Weiterverarbeitung verantwortlich.[...]
    Da digitale Signale nicht im Hardware-Takt erfasst werden können, müssen diese Signale parallel in Software-Takten ermittelt werden. Dies kann zu zeitlichen Verschiebungen führen, weil sowohl beim Start der Messung als auch während der Messung keine Synchronisierung der Timer im PC und im Messgerät erfolgen kann. Da zwei Timer nie ganz genau gleichzeitig gestartet werden und auch nie ganz genau gleich schnell laufen, stimmen die Zeiten in den Zeitkanälen nach der Messung nicht genau überein. Üblicherweise betragen die Abweichungen einige Millisekunden.[...]
    Weiters hab ich mal n Versuchsaufbau für die Frequenzmessung gemacht. Ich konnte problemlos Frequenzen messen...
    Am besten du schilderst kurz den Aufbau deiner Messung, was du messen möchtest und wie du den Max konfiguriert hast.
    Mfg Markus

  • Timeout waiting for ARP/RARP packets

    I am installing Solaris 8 for the first time on an Ultra 5. It has a network card and attached to my 10mbps Hub which is connected to Cable Modem. Problem: While the system was rebooting after the install, the system generated the error trying to link up to the Hub (timeout waiting for ARP/RARP packets). During the install I chose "non-networked" because I could not answer the other questions such IP address name Service etc..
    I want to set it up as a server so that I can use 2 other PCs to access the Oracle, mail and other stuff that would eventually run on it.
    What do I do?
    Renald

    Typically the message "waiting for ARP/RARP packet" will only be generated when no other boot device is available or net is set as the primary boot device. First thing to do is check your env settings to ensure that boot-device = disk net. Second, to reenable network support to the system the easiest way is to do a sys-unconfig and enter the requested information. You need to have the following information available. Hostname, IP address, subnet mask, Name service (if any), Name service settings (name and IP address of server). Some of the information may be available from your ISP on what exact address`s you should be using. Since the message came up and if the boot-device setting is correct I would check the connection to the hard disk.
    Lane

Maybe you are looking for