Trigger the modelsupport2.dll from parallelmodel.seq

I want to trigger/control the modelsupport2.dll interface by putting it into different modes like "running" "terminating" etc. from the Parallelmodel.seq. As it is right now, the operator needs to press the "OK", "Next UUT" button, I want to skip this. My question is simply. How does the dll call look like from parallelmodel?
Regards Fredrik Westberg

Hi Fredrik,
There is an example in '\TestStand 2\Examples\Callback\ParallelModel' which may help you.
Setting the ModelOptions.ParallelModel_ShowUUTDlg to False will allow you to provide your own mechanism. Then its a case of setting up the TestSocket container.
Hope is provides some help.
Ray Farmer
Regards
Ray Farmer

Similar Messages

  • How to trigger the BPM process from WD Application

    Hello All,
    I have a simple business process with two ui activities. I am able to start the process from NWA -> Process Repository.
    But, I need to start the process from the application. Here is the requirement:
    User opens the application. ON completion, the BPM process for approval needs to be triggered. How do i access/obtain process?
    If I need to call a particular task in process, How do i do that?
    Kindly assist.
    Thank you.
    Regards,
    Sharath

    if you want to know the whole story, please refer to the doc
    http://help.sap.com/saphelp_nwce72/helpdata/en/44/4d2bb1c6b00597e10000000a155369/frameset.htm
    the profile, provider system,endpoint。。。。。
    search this doc in sdn, it is a good example regarding the configuration.
    How to Use SOA Configuration to Call RFCs and Web Services from within SAP NetWeaver BPM
    hope those may help.

  • Is it posible to trigger the rejection activity from backend?

    We have an issue in production with a candidate whom the recruiter wants to send a rejection to. But when the activity is chosen the correspondence is instead the invite letter (hrrcf_CS_IT_invite), this should have been hrrcf_CS_IT_rejection.
    So far its only this one candidate who has this problem.
    So the question is, is there a way to complete the activity from backend?
    I am thinking something like transaction se24 => CL_HRRCF_CANDIDATE_APPLICATION => F8 => method GET => enter application ID => F8 => ???? is it possible to push it forward?

    Hi Mathias
    Yes you can send the letter from backend using SOST t-code.
    First check the SOST t-code and see how many communicaion sent to that candidate.
    You can also check the workflow triggered for that candidate in SWIA and SWI5 if it is not correct then you have to check with the workflow team.
    I hope it will help you to solve the issue.
    Cheers
    Rahul
    Message was edited by: Rahul Singh

  • Is it possible to trigger the next event from within the event case?

    I have a rather complicated event that is triggered by a change in value of a particular button in the interface. In some cases, I want to alter that button's value when handling other events. But when I do this, the event handling a change in value for that button does not get triggered. Is there a way to make sure the value change event gets handled at the next iteration of the while loop in which the event structure sits?
    Solved!
    Go to Solution.

    Hi Mike,
    Thanks! I was using properties and did not previously know what the value(signaling) was. Knowing this will really help me clean up a lot of redundant code.

  • Using ModelSupport2.dll in LabView without TestStand

    I would like to use the ModelSupport2.dll purely in a LabVIEW environment as either by a "Call Library Function Node" or "Active X" or ".NET" without using TestStand.
    In particular I would utilize the the "DisplayPassBanner" and "DisplayFailBanner" functions. I want the banner pop-up's so I can provide a consistency between applications that don't use TestStand and those that do.
    The DLL call requires a numeric input "context" which I am not sure what it needs for a reference number.
    In teststand it is passed an "Object", "CVI Active X Automation Handle", "By Value" from the "ThisContext"
    How replicate this or create equivalent in LabVIEW
    Any suggestions appreciated
    A

    A,
    if you are looking into the sources of ModelSupport2.dll (the sources are included as LabWindows/CVI project and the needed C files), you will see that the display banner functions do access the object referenced by the parameter 'context'. The context is a reference to the dataset of a running TestStand execution when called from the TestStand process model.
    So it will not be possible to use those functions if you are not going to use TestStand/running an actual sequence.
    There are, however, two ways you can go for:
    a) Design a LV VI dialog such way that it looks like one of the banner and call it as a subVI.
    b) Use the LabWindows/CVI sources of ModelSupport2.dll to copy the banner dialogs into a new CVI project (from modelpanels.uir) and create similar functions into a custom written dll which do not require the ActiveX handle 'context' to be passed.....
    hope this helps,
    Norbert
    CEO: What exactly is stopping us from doing this?
    Expert: Geometry
    Marketing Manager: Just ignore it.

  • Modelsupport2.dll changes don't take affect

    Running TestStand 4.0 and LabWindows/CVI 9.0.1.
    Followed instructions per http://digital.ni.com/public.nsf/allkb/A6D0EF1F4FE5EC94862570AE000CE374 to change my test socket numbers to be non zero based for batch model.  Also modified paralleluutdlg.c to increase the MAX_NUM_TEST_SOCKETS_VISIBLE 6 (used to be 5).
    The modelsupport2.dll compiled successfully, but the changes do not occur when I run my sequence file using the batch model; i.e., the test sockets still start from 0 instead of 1 and the number of visible sockets is 5 and not 6.
    I checked the configured search directories and the user components directory (containing my modified files) is ahead of the default NI components directory as desired.
    Am I missing a required step here?
    Thanks!
    Solved!
    Go to Solution.

    Hi George,
    The KnowledgeBase article you are referring to is for the parallel model, not the batch model. However, if you open the batchuutdlg.c and search for the same line of test as described in the KB and add "+1" to it, it should work. I have confirmed that it works on my end. Just to make sure this is clear, this only changes the dialog box and will not change the numbering in the process model. Changing that numbering requires a much more extensive effort.
    Regarding the MAX_NUM_TEST_SOCKETS_VISIBLE 6 change, I have also done this and it does show 6 visible batches in the dialog box. Please keep in mind that you need to just replace the number without changing the spacing on the line. You will also need to go into Configure->Model Options and change the Number of Test Sockets to 6 to ensure that you see the 6 visible batches. Changing this will cause the window to expand over the "Go" and "Stop" buttons so there will have to be more extensive changes to move those buttons down. I hope this helps address your question!
    Regards,
    Jackie
    DAQ Product Marketing Engineer
    National Instruments

  • TestStand LabVIEW OI and modelsupport2.dll

    I'm trying to understand how to do some customization of the LabVIEW version of the TestStand (3.5) Operator Interface.  I need the default OI to change in several areas.  One in particular is that a teamate company (dictating the look and feel) wants us to have a Data Entry dialog.  They say that it's part of the TestStand Sequential Process Model and it's contained in ModelSupport2.dll, and that it contains its own GUI that is used by the process models.
    I hope to develop tests in LV8.  As a first step, I'm trying to understand how (and when) to call the functions within the modelsupport2.dll.  I there any documentation on the functions within (other than the .h)?  Can someone walk me through an example where a sequence file (or is the call made from LabVIEW?) displays some dialog that is supposedly in modelsupport2.dll?

    There's several dialogs in modelsupport2. There's the serial number dialogs for the sequential model, parallel model, and batch model. The only other dialogs are for the report file options and model options. The last two are what you get when select Configure>Report Options and Configure Model Options. The serial number dialogs are called in the process model like the other company said and I don't know of any test sequence or OI that would call them directly. If you want to override them and use your own serial number dialog, then you can put own callback in a sequence.

  • Why is the kernel32.dll being included with my executable?

    It's actually being included in the support files folder with the other dll's necessary for the executable.  It is not required for my executable, however, and when I put the executable on a computer outside of the development environment, the executable breaks when it runs.  If I delete the kernel32.dll from the support folder, the executable runs fine on the stand alone computer.  The frustrating thing about this is that this is new behavior for making this particular executable.  My development computer started adding the kernel32.dll to my executables that contain a certain sub vi a couple of months ago.  The offending sub vi has no library function calls to the dll that I can find or knowingly added. If I use a different development computer with the exact same source code and project file, the kernel32 dll is NOT included in the support folder.  It is only my particular development computer.  I looked at all the posts that contain a reference to the executables with kernel32.dll, like the one in the Knowledgebase "My Stand-Alone Executable Cannot Find My DLL, Even Though I Have Specified the Path for the DLL" and tried to add the system32 folder to the vi search path, but that did not do anything. I looked through all of the Options pages but did not find anything that seemed relevant.  Did I miss some setting that I inadvertantly modified to start getting this behavior?
     
    Please let me know what I can look for to try and fix this problem.  It is not an acceptable solution to have users go into the support folder and delete this file after the program is installed on their computer.  It is also not reasonable for me to use a different computer each time I want to create an executable, and I really don't want to reinstall all of the many parts and modules of LV on my computer.
     
    Thanks,
    Craig

    Duplicate post

  • How to call Labview DLL from VB2005

    Dear all expert,
    I'm a student and very new in Labview programming.
    Currently i have build a simple vi and need to convert it to dll so that i can call it from my VB.net. But the problem is how to call the labview dll from my VB.net?
    I know we must declare function something like this,
    Auto function Bodeplot Lib"..\\Bodeplot.dll" (Byval Val1 as double, Byval Val2 as double,...) as double
    but how to determine Val1, Val2 (and so on) is input for which data?  if my vi have 10 input (frequency, Kc,Fcz,Fcp,Wzrhp,Wp,k,Wz,Beta and Operation) ? and how to select the output (my application have 3 possible output : magnitup loop,phase loop, and degree loop)
    In addition, since I'm using Labview 8.0 , and as i know apllication  builder for this version cannot convert vi to dll which contain Mathscript (but unfortunely, my vi all use Mathscript), so really hope someone can help me to convert my vi to dll using Labview 8.2 (which remove this limitation).
    here I'm attach my Vi and really hope someone willing to help.
    Thank you.
    Attachments:
    bodeplot.vi ‏1049 KB

    On Sep 17, 6:40 am, cckoh <[email protected]> wrote:
    > Dear all expert,
    > I'm a student and very new in Labview programming.
    > Currently i have build a simple vi and need to convert it to dll so that i can call it from my VB.net. But the problem is how to call the labview dll from my VB.net?
    > &nbsp;
    > I know we must declare function something like this,
    > &nbsp;
    > Auto function Bodeplot Lib"..\\Bodeplot.dll" (Byval Val1 as double, Byval Val2 as double,...) as double
    > &nbsp;
    > but how&nbsp;to determine Val1, Val2 (and so on) is input for which data?&nbsp; if my&nbsp;vi have&nbsp;10 input (frequency, Kc,Fcz,Fcp,Wzrhp,Wp,k,Wz,Beta and Operation)&nbsp;? and how to&nbsp;select the output (my application have 3 possible output : magnitup loop,phase loop, and degree loop)
    > &nbsp;
    > In addition, since I'm using Labview 8.0 , and as i know apllication&nbsp; builder for this version cannot convert vi to dll which contain Mathscript (but unfortunely, my vi all use Mathscript), so really hope someone can help me to convert my vi to dll using Labview 8.2 (which&nbsp;remove this limitation).
    > &nbsp;
    > here I'm attach my Vi and really hope someone willing to help.
    > &nbsp;
    > Thank you.
    > &nbsp;
    >
    > bodeplot.vi:http://forums.ni.com/attachments/ni/170/272124/1/bodeplot.vi
    If you insist on using Labview with your project then you should
    consider using ActveX in place of using a dynamic link library to
    interface to your VB.net code. You don't need "Application Builder"
    if you use ActiveX. The Student, Basic and Full development versions
    of Labview for Windows come with ActiveX capability. For more
    information on ActiveX look up the subject ActiveX in Labview's Help
    File.
    Howard

  • How to write a procedure to run the call the custom package from backend

    Hi All
    Oracle 10g
    Oracle Apps R12
    I am working with oracle order management here we have a customize Package called (Pick Release).Due to some problem we have running this concurrent program by manually giving Route_id as parameter. The route_id is taken from the route Table. By using this query
    select distinct route_id from route@DB_LINK_APPS_TO_ROADSHOW
    where trunc(route_date) = trunc (sysdate+2).
    so daily we have nearly 42 routes and we are running this concurrent program manually nearly times.
    so now how to write a procedure for this
    Step 1 Getting the route from route table.( By cursor we can get the route_id Accordingly)
    Step 2 How to trigger the custom package from back end and execute accordingly to that output of the cursor(route_id)
    If the cursor get 40 routes is it then the concurrent program runs 40 times according to that route_id.
    can some could provide the steps to do this
    Thanks & Regards
    Srikkanth.M

    This is about 4 or 5 lines of PL/SQL and the name of the custom package is not provided.
    If you request someone in this forum to do your work for free -because obviously you didn't even try to write it, which must be considered abusing this forum- you must at least provide sufficient info so someone can do it.
    And no, I won't do it for you.
    Sybrand Bakker
    Senior Oracle DBA

  • Not able to find the GpibDevEnv.dll

    I am currently updating a vb 6 application and need to add a power analyzer to it that requires the GpibDevEnv.dll. The path for the dll and dll name is listed in the references for my project, but when i go to the folder it is suppose to be in, it is not there. Is there a place where I can get the GpibDevEnum.dll from and load onto my system?
    Thanks

    Duplicate post, please refer to this post.
    Message Edited by pBerg on 03-13-2008 11:52 AM
    Warm regards,
    pBerg

  • Transferring the cost centers from ECC to Sourcing

    Hello Experts
    I have a requirement to synchronize cost centers between ECC and Sourcing systems . . The approach I am thinking is-
         Schedule a import job in sap sourcing which will be pointed to FTP and can import data.
         ECC will  trigger the XML data from  for any change / creation of cost centers .
         This data will come to FTP and from there this would be imported by Sourcing .
    Can anyone let me know if there is any particular XML format for Cost centers for  importing to Sourcing ?
    Thanks
    Sudipta

    Hi Sudipta,
    If Cost Center data extracted from ECC is rendered in CSV format, then XML file may not be required for the import job.
    The CSV file format should be available in the Enterprise/Company workbook.
    Regards,
    Parankush

  • Accessing a dll from classes in different packages

    Hello java community,
    I am new to Java and especially the jni so your help is greatly appreciated.
    I am having trouble accessing a Windows native dll from classes in different packages. I placed the .dll in my ClassPath. I am able to loadLibrary successfully from class X in my 'common' package. However, when I try to access the same .dll from another class Y in package 'notsocommon'. I get an unsatisfied link error. I changed the X.h file to include common in the function definition (eg. Java_common_X_functionName) and I did the same to the Y.h file (Java_notsocommon_Y_functionName). I am able to work with the dll from the X class but not the Y class. I don't know what I am doing wrong. I am very new to Java, so any help is appreciated.
    Thank you.

    I apologize to everyone for posting this. I figured out my mistake, it was in the dll and not in the java. Also using
    javah -jni notsocommon.Y
    creates the correct header file.

  • I just installed LV2011 and one dll from my vi won't load with the error "application configuration is incorrect"

    I just installed LV2011 and one dll from my vi won't load with the error "application configuration is incorrect", which is Windows lingo for "missing package dependencies".  All the computers at my company with 2010 loaded seem to do OK.  When I do a Dependencies Walk I get missing Visual C debug dll's missing plus IEshims and wer which both have a whole tree of dependencies missing on my machine.  The Windows install is the same "Windows XP version 2002 Service Pack 3" on my PC and the working PC's. So I'm thinking I have to uninstall 2011 and go back to 2010.  Is this correct?  Those VC debug dll's were installed on the machines with 2010 in them but were not installed in mine.
    I've heard the advice to recompile the dll with debug turned off but I don't have access to the source code.
    Thanks in advance.

    u87 wrote:
    Thanks for the reply.  This at least tells me that going back to LV2010 is not likely to solve the problem.  The missing dll's are:
    MFC90D.dll
    MSVCR90D.dll
    IESHMS.dll
    WER.dll
    And, once again, IESHMS and WER have other dependencies.  So perhaps i need to install the Visual C++ development environment.
    IESHIMS.dll is an Internet Explorer DLL that gets usually delay loaded by shdocvw.dll. As delay load it can not cause DLL load errors but only runtime errors. Maybe your DLL has it as direct dependency but that is unlikely since it does not have a documented interface.
    WER.dll is Windows error reporting for Vista/Win7.
    MFC90D.dll is the Microsoft Foundation classes and MSVCR90D.dll is the MS C runtime library, both as debug variant.
    So all the DLLs you mention are actually MS DLLs! You haven't identified the DLL that you try to access in LabVIEW that causes these error messages. IESHIMS and WER are usually delay loaded by any component that needs it and should not likely be used by non MS code.
    What is the DLL you try to load into LabVIEW and by whom? Get the provider of that DLL to provide you a non Debug build of the DLL. Installing Visual C on all the machines just to make the DLL load is not a solution, besides that it is likely not legal since I doubt you have that many licenses.
    Rolf Kalbermatter
    CIT Engineering Netherlands
    a division of Test & Measurement Solutions

  • Automatically trigger the event to load data from Planning cube to Standard Cube

    Hello,
    We have a below set up in our system..
    1. A Planning BEx query using which user makes certain entries and writes back data to the planning cube.
    2. An actual reporting cube which gets data from the planning cube above.
    Now, what we want to do is to automate the data load from Planning cube to Reporting cube.
    This involves 2 things..
    1. Change the setting " Change real time load behaviour " of the planing cube to Planning.
    2. Trigger the DTP which loads data from Planning cube to reporting cube.
    We want to automate the above two steps...
    I have tried few things to achieve the same..
    1. Created an event in SM64,
    2. In the Planning cube "Manage" Screen,  clicked on "Subsequent Processing" and provided the event details. ( Not sure if its the correct place to provide the event detail ).
    3. Wrote a ABAP program which changes the setting of the planning cube (  " Change real time load behaviour " to Loading )
    4. Created a process chain, where we have used the event as a start variant, used the ABAP program as a next step, DTP run as the last step..
    This i hoped, would trigger the event as soon as a new request comes and sits in planning cube, which in turn would trigger the process chain which would load the data from Planning cube to reporting cube..
    This is not working. I dont think the event is triggering, and even if does i am not sure whether it will start the process chain automatically. Any ideas please ?

    hi,
    try to do the transformation directly in the input cube by using CR of type exit, more details :
    http://help.sap.com/saphelp_nw70ehp2/helpdata/en/43/1c3d0f31b70701e10000000a422035/content.htm
    hope it helps.

Maybe you are looking for

  • Add single computer to multiple collections listed in a file

    Good afternoon, I am trying to figure out how to add a single computer to multiple collections based on the contents of a file. Basically, I have a frontend hta for deployments. On that hta are checkboxes for various bits of software that should be i

  • Display mode in me23n

    Hi, I have added a new field in me23n transaction.Its coming in change mode.iam using user exit MM06E005 for adding the new field.How can i change the field to come in display mode?Can anyone suggest the function module in this exit where can i code.

  • Whenever it is not active, Firefox Mobile 10 constantly uses 10-40% CPU

    Samsung Galaxy S Infuse 4g (aka "Galaxy S 1.5") with Gingerbread. While it is the active application, Firefox seems to be using reasonable amounts of CPU. If it is not active, though, it constantly uses 10-40%, until it gets background killed, which

  • IPhoto does not import HD video/MTS files for Panasonic Lumix DMC-LX5.

    Hello, everyone. I'm using iPhoto '11 on an iMac i7. I recently bought the Panasonic Lumix DMC-LX5, which records HD video (AVCHD Lite). When I insert the memory card into my iMac, it recognizes and imports all photos. However, the videos are left on

  • Which column refers organization_id in RA_CUSTOMER_TRX_LINES_V  ?

    Hi All, We ae trying pick value of ITEM AND ITEM DESCRPTION based on TRX NUMBER we use below query for that SELECT CH.TRX_NUMBER, MTL.SEGMENT1, MTL.DESCRIPTION FROM APPS.RA_CUSTOMER_TRX_LINES_V CL, APPS.RA_CUSTOMER_TRX_PARTIAL_V CH, APPS.MTL_SYSTEM_I