UCS: Migrating network to port channels

Hello all,
I've searched around for the answer, so forgive me if this question is has already been answered and I just missed it.
The short and skinny is that because of the need to have a disjointed L2 network, without changing from EHM to Switch mode and on top of security polices (the two L2 networks are Corporate and DMZ), it was recommended that we switch to using port channels.
Right now, I have two UCS 6120s in a cluster.  Each 6120 has two uplinks to a pair of Cisco 4948s, configured as standard trunk uplinks.
I guess the actual question(s) is
A) Can this be done without bringing down the entire network for the UCS?
B) If it can, what is the best way to do it without interruption?
I've searched for around and the only thing I've seen is the steps to make the changes in the UCS Manager, but from what I can tell it assumes it’s a new install of UCS and not something that's already in production.
I already had the networking guys set up the port channels on two unused ports on the 4948s, so all I need to do is move the cables and setup the port channel in the UCSM.
My plan of action is as follows:
- disable the network uplinks on one of the 6120s, this should force all traffic to the other side (is that correct?)
- move the network cables coming from the 6120 to the 4948 switche to the new ports set up as a port channel
- create the port channel in the UCS manager
- Enable uplink ports and enable port channel
- Re-do the above steps for the other 6120.
Is the above possible without causing an interruption?  Also during the transition, will there be a problem where one side is using a port channel and the other side is still using the regular trunk uplinks?
Thanks for any suggestions or help.
(This was neither short nor skinny)

If you need setup UCS for disjointed L2 and you only have 2 LAN uplinks you are not going to be able to place those 2 into a port-channel and also be able to configure disjointed L2.
Are you adding 2 additional uplinks to the ones you already have?
If you aren't planning on adding 2 additional uplinks then you will need to use them as single links; 1 with corporate VLANs mapped and the other with DMZ VLANs mapped. You will do this for both Fabric Interconnect A and B so that each Fabric interconnect as 1 uplink for corporate and 1 for DMZ.
This configuration requires UCS firmware 2.x
Like you are planning you will do this on 1 fabric at a time.
On Fabric A disable the 2 LAN uplinks so that all traffic is forced to go out Fabric B
Use the UCS VLAN Manager to map the DMZ VLANs to the DMZ uplink and the corporate VLANs to the corporate uplink. You can SSH into UCS, type "connect nxos a" and type "show interface trunk" to verify the VLANs are mapped properly
Make sure the 4948 switch is configured to trunk the correct VLANs over the correct links
Enable the ports on Fabric A
Do the same for Fabric B

Similar Messages

  • Create port channel between UCS-FI and MDS 9124 (F Mode)

    Dear Team,
    We were trying to create  port channel between UCS FI and MDS 9124
    But the port channel not getting active in F mode on MDS 9124
    FI is in FC End Host Mode
    We have enabled FC uplink trunking on FI
    We have enabled NPIV on MDS
    We have enabled trunk on MDS
    FI and MDS in default VSAN
    To check we changed the FI mode to FC Switching mode and port channels became active but in E mode
    when we enabled FC uplink trunking on FI and FC Switching mode port channels became active in TE mode
    but in both the above cases showflogi database shows WWPN of SAN alone not showing any from FI.
    How to achive this?
    Have read that no need to change the swicthing mode to FC Switching mode and keep as FC Endhost mode
    SO how to achieve Port channel with F mode in MDS and FI ( Mode showing as NProxy)
    Does it has to do anything with MDS NX-OS version? (https://supportforums.cisco.com/thread/2179129)
    If yes how to upgrade as license for ports came along with Device and we do not have any PAC/PAK or license file as it came
    with license
    Also we have seen 2 files availabe for download (m9100-s2ek9-kickstart-mz.5.2.8b.bin and m9100-s2ek9-mz.5.2.8b.bin) which to use
    Thanks and Regards
    Jose

    Hi Jo Bo,
    what version of software if your MDS running?
    On your UCS do connect nxos and show inteface brieft and look at the mac address.
    it is possible that you might be hitting the bug below. if this is the case you might need to upgrade the firmware on your MDS.
    Add MAC OUI "002a6a", "8c604f", "00defb" for 5k/UCS-FI
    http://tools.cisco.com/Support/BugToolKit/search/getBugDetails.do?method=fetchBugDetails&bugId=CSCty04686
    Symptom:
    Nexus switch unable to connect any other Nexus or other Cisco Switch in NPV mode with a F port-channel.   Issue might be seen in earlier 5.1 releases like
    5.1.3.N1.1a
    but not the latest
    5.1.3.N2.1c
    release. Issue is also seen in
    5.2(1)N1(1)
    and
    6.0(2)N1(1)
    and later releases.
    Conditions:
    Nexus configured for SAN PortChannels or NPIV trunking mode Nexus connected to UCS via regular F port channel where UCS in NPV mode  NPV edge switch: Port WWN OUI from UCS FI  or other Cisco manufactured switch:  xx:xx:00:2a:6a:xx:xx:xx   OR  xx:xx:8c:60:4f:xx:xx:xx
    Workaround:
    Turn-off trunking mode on Nexus 5k TF-port Issue does not happen with standard  F-PORT Remove SAN Portchannel config
    Further Problem Description:
    To verify the issue please collect  show flogi internal event-history errors  Each time the port is attempted OLS, NOS, LRR counters will increment. This can be determined via the following output,  show port internal info all show port internal event-history errors

  • FC Port Channel between UCS and MDS.

    Hi All,
    I am new to Cisco Fabric Concepts. In my enviornment i have a F port channel(8 Port Group) created on MDS 9513 switch and this Fport 
    channel is connected to Cisco UCS 6296 FI. The Cisco UCS Blade servers are connected to the Fabric Interconnect .
    On MDS NPIV is enabled.
    Can anyone explain the below questions.
    1. Why do we create an F port Channel Group and connect it to the UCS FI? Is this something similar to Brocade Edge to AG Switch Connectivity.
    2. How to configure F port Channel Group in MDS . Can anyone explain with an example.
    3. Do we need to make any Configuration on UCS FI ports for server connectivity and Channel port Connectivity if yes what are the steps required to 
    do the same.Does the WWPN shows up in the FLOGI Database if the connectivity and configuration looks good in UCS FI and MDS.
    4. What happens when a VSAN on MDS switch is added to the Port Channel.
    Thanks and Regards,
    Santosh surya

    Look at my remarks in
    https://supportforums.cisco.com/discussion/12468266/fc-port-channels-between-mds-and-ucs-fi-best-practice
    1. Why do we create an F port Channel Group and connect it to the UCS FI? Is this something similar to Brocade Edge to AG Switch Connectivity.
    F port channel is proprietary; therefore any such F port channel between UCS FI and Brocade doesn't work.
    2. How to configure F port Channel Group in MDS . Can anyone explain with an example.
    see eg.
    https://supportforums.cisco.com/sites/default/files/legacy/9/9/2/53299-UCS_1-4-1_F-port_channel-trunk-v1.pdf
    3. Do we need to make any Configuration on UCS FI ports for server connectivity and Channel port Connectivity if yes what are the steps required to 
    see eg.
    https://supportforums.cisco.com/sites/default/files/legacy/9/9/2/53299-UCS_1-4-1_F-port_channel-trunk-v1.pdf
    Does the WWPN shows up in the FLOGI Database if the connectivity and configuration looks good in UCS FI and MDS.
    flogi database is on the MDS, not FI; there are however UCS CLI commands, like "show npv ...."
    4. What happens when a VSAN on MDS switch is added to the Port Channel.
    If its not created on UCS, it will just not become the status "up"

  • MDS Code Level for UCS FC Port Channel/Trunking

    What is the required MDS code level needed to support FC Port-Channeling/Trunking on a 9222i, 9148, or 9509/9513 w/ Gen2 line cards to UCS 1.4(3)?
    I know the fport-channel-trunk feature is needed and was released in MDS 4.2 code but I have seen documents that this level of code wont support these features when used to connect to Cisco UCS. 
    Can someone confirm?  Is NXOS 5.0(4) or higher required?

    Doug,
    I wrote the doc almost a year ago and it doesn't have the latest interop matrix support information. The current MDS NX-OS support is located in this doc: http://www.cisco.com/en/US/docs/switches/datacenter/mds9000/interoperability/matrix/intmatrx.html
    While, I wish this was also duplicated in UCS docs, they are more or less taking the stance that 3rd party (Cisco MDS is this case) interop is maintained by the 3rd party. EMC, Netapp, or even Cisco.
    It would be a nightmare updating UCS docs with 3rd party qualifications and support.
    The short answer to your question is:
    UCS 1.4(1), 1.4(2), 1.4(3) Is supported by MDS9000: 3.3(4a), 3.3(5), 4.2(1a), 4.2(1b), 4.2(3a), 4.2(5), 5.0(1a), 5.0(4), 5.0(4c)
    NPV was introduced in MDS 3.3. f port-channel/trunk was introduced in MDS 4.2.
    As Ram mentioned above, 4.2(5) is what I would recommend if I wanted to implement f port-channel and/or f port-trunk. I have also had recent experience with 4.2(5) and it worked great with a large UCS f port-channel/trunk implementation
    The specific switch limitations I mentioned in my doc still exist. Only certain models of MDS will support f port-trunk. Almost all models will support f port-channel.
    Dave

  • FC port channels between MDS and UCS FI best practice?

    Hi,
    We would like to create FC port channels between our UCS FI's and MDS9250 switches.
    At the moment we have 2 separate 8Gbps links to the FI's.
    Are there any disadvantages or reasons to NOT do this?
    Is it a best practice?
    Thanks.

    As Walter said, having port-channels is best practice.  Here is a little more information on why.
    Let's take your example of two 8Gbps links, not in a port-channel ( and no static pinning ) for Fibre Channel connectivity:
    Hosts on the UCS get automatically assigned ( pinned ) to the individual uplinks in a round-robin fashion.
    (1)If you have some hosts that are transferring a lot of data, to and from storage, these hosts can end up pinned to the same uplink and could hurt their performance. 
    In a port-channel, the hosts are pinned to the port-channel and not individual links.
    (2)Since hosts are assigned to an individual link, if that link goes down, the hosts now have to log back into the fabric over the existing working link.   Now you would have all hosts sharing a single link. The hosts will not get re-pinned to a link until they leave and rejoin the fabric.  To get them load balanced again would require taking them out of the fabric and adding them back, again via log out, power off, reload, etc...
    If the links are in a port-channel, the loss of one link will reduce the bandwidth of course, but when the link is restored, no hosts have to be logged out to regain the bandwidth.
    Best regards,
    Jim

  • Port-Channel MDS & UCS with a particular vsan

    I am having trouble setting up a  port-channel between MDS & UCS with a particular vsan. I was able to get a port-channel setup on VSAN 1 between and MDS9513 5.0(4d) and UCS 6120 XP 4.2 (1). When I try to do it with a specifc VSAN it fails. I set the VSAN on the 9513 interfaces and created the port-channel but it looks like it still wants to default to VSAN 1 when I do a  sh int. I have added the same VSAN on the UCS side as well. I have tried to see if could set the vsan on the port-channel but it doesn't look like that command is offered. Any ideas?

    Hello
    Having no exp of UCS switches, this may be a bit off, but....
    The vsan the port channel PORTS are in is of no consequence.  The VSAN's that are allowed to traverse the trunk are the important bits.  i.e:
    interface port-channel 1
      switchport trunk allowed vsan 1
      switchport trunk allowed vsan add 60
      switchport trunk allowed vsan add 80
    Steven

  • Port-Channel issue between UCS FI and MDS 9222i switch

    Hi
    I have a problem between UCS FI and MDS switch port-channel. When MDS-A is powered down the port-channel fails but UCS blade vHBA does not detect the failure of the port-chanel on UCS-FI and leaves the vHBA online. However, if there is no port-channel between FI-->MDS it works fine.
    UCS version   
    System version: 2.0(2q)
    FI - Cisco UCS 6248 Series Fabric Interconnect ("O2 32X10GE/Modular Universal Platform Supervisor")
    Software
      BIOS:      version 3.5.0
      loader:    version N/A
      kickstart: version 5.0(3)N2(2.02q)
      system:    version 5.0(3)N2(2.02q)
      power-seq: Module 1: version v1.0
                 Module 3: version v2.0
      uC:        version v1.2.0.1
      SFP uC:    Module 1: v1.0.0.0
    MDS 9222i
    Software
      BIOS:      version 1.0.19
      loader:    version N/A
      kickstart: version 5.0(8)
      system:    version 5.0(8)
    Here is the config from MDS switch
    Interface  Vsan   Admin  Admin   Status          SFP    Oper  Oper   Port
                      Mode   Trunk                          Mode  Speed  Channel
                             Mode                                 (Gbps)
    fc1/1      103    auto   on      trunking         swl    TF      4    10
    fc1/2      103    auto   on      trunking         swl    TF      4    10
    fc1/9      103    auto   on      trunking         swl    TF      4    10
    fc1/10     103    auto   on      trunking         swl    TF      4    10
    This is from FI.
    Interface  Vsan   Admin  Admin   Status          SFP    Oper  Oper   Port
                      Mode   Trunk                          Mode  Speed  Channel
                             Mode                                 (Gbps)
    fc1/29     103    NP     on      trunking         swl    TNP     4    103
    fc1/30     103    NP     on      trunking         swl    TNP     4    103
    fc1/31     103    NP     on      trunking         swl    TNP     4    103
    fc1/32     103    NP     on      trunking         swl    TNP     4    103
    Any thoughts on this?

    Sultan,
    This is a recently found issue and is fixed in UCSM 2.0.3a version .
    http://tools.cisco.com/Support/BugToolKit/search/getBugDetails.do?method=fetchBugDetails&bugId=CSCua88227
    which got duped to  CSCtz21585
    It happens only when following conditions are met
    FI in End host mode
    FC uplinks are configured for portchannel + trunking
    Certain link event failures ( such abrupt power loss by upstream MDS switch )
    Padma

  • UCS - san-port-channel over vpc

    Hi,
    I'm hoping someone can help out with this,
    I have a setup with 2 Nexus 5548's connected over a vpc peer link and a keepalive, These two nexus switch's have a standard VPC connection to an upstream 6500. this is working fine,
    Then there are multiple native FC connections from the 5548's to 6248's. I know there is the option to configure FC port-channel's on the UCS 2.0 but is it possible to put fc interfaces of the nexus 5548 into a san port-channel across a vpc between the the nexus 5548's.
    so for example, can i port-channel the following across a vpc or is a san port-channel restricted to ports on the same nexus switch only.
    Fabric A  fc1/31 & fc1/32    uplinked to  -> NX5K-1  Port fc1/31 & NX5K-2 Port fc1/32 (san port-channel 10 over a VPC)
    Fabric B  fc1/31 & fc1/32    uplinked to  -> NX5K-1  Port fc1/32 & NXFK-2 Port fc1/31 (san port-channel 11 over a VPC)
    Thanks,
    Ray.

    This is not possible. Vpc is layer 2 only ethernet port channel. San port channel cannot be built accross vpc
    Sent from Cisco Technical Support iPhone App

  • UCS FI 6248 to Nexus 5548 San port-channel - not working

    Hi all,
    I'm sure I am missing something fairly obvious and stupid but I need several sets of eyes and help.
    Here is the scenario:
    I want to be able to create san port-channels between the FI and Nexus.  I don't need to trunk yet as I can't even get the channel to come up.
    UCS FI 6248:
    Interfaces fc1/31-32
    Nexus 5548
    interfaces fc2/15-16
    FI is in end-host mode and Nexus is running NPIV mode with fport-channel-trunk feature enabled.
    I'm going to output the relevants configurations below.
    Nexus 5548:
    NX5KA(config)# show feature | include enabled
    fcoe                  1         enabled
    fex                   1         enabled
    fport-channel-trunk   1         enabled
    hsrp_engine           1         enabled
    interface-vlan        1         enabled
    lacp                  1         enabled
    lldp                  1         enabled
    npiv                  1         enabled
    sshServer             1         enabled
    vpc                   1         enabled
    interface san-port-channel 133
      channel mode active
      no switchport trunk allowed  vsan all
      switchport trunk mode off
    interface fc2/15
      switchport trunk mode off
      channel-group 133 force
    no shutdown
    interface fc2/16
      switchport trunk mode off
      channel-group 133 force
    no shutdown
    NX5KA# show vsan membership
    vsan 1 interfaces:
        fc2/13            fc2/14          
    vsan 133 interfaces:
        fc2/15            fc2/16            san-port-channel 133
    vsan 4079(evfp_isolated_vsan) interfaces:
    vsan 4094(isolated_vsan) interfaces:
    NX5KA# show san-port-channel summary
    U-Up D-Down B-Hot-standby S-Suspended I-Individual link
    summary header
    Group  Port-      Type    Protocol               Member Ports
           Channel
    133    San-po133  FC      PCP      (D)  FC       fc2/15(D)    fc2/16(D)   
    UCS Fabric Interconnect outputs:
    UCS-FI-A-A(nxos)# show san-port-channel summary
    U-Up D-Down B-Hot-standby S-Suspended I-Individual link
    summary header
    Group  Port-      Type    Protocol               Member Ports
           Channel
    133    San-po133  FC      PCP      (D)  FC       fc1/31(D)    fc1/32(D)   
    UCS-FI-A-A(nxos)#
    UCS-FI-A-A(nxos)# show run int fc1/31-32
    !Command: show running-config interface fc1/31-32
    !Time: Fri Dec 20 22:58:51 2013
    version 5.2(3)N2(2.21b)
    interface fc1/31
      switchport mode NP
      channel-group 133 force
      no shutdown
    interface fc1/32
      switchport mode NP
      channel-group 133 force
      no shutdown
    UCS-FI-A-A(nxos)#
    UCS-FI-A-A(nxos)# show run int san-port-channel 133
    !Command: show running-config interface san-port-channel 133
    !Time: Fri Dec 20 22:59:09 2013
    version 5.2(3)N2(2.21b)
    interface san-port-channel 133
      channel mode active
      switchport mode NP

    !Command: show running-config interface san-port-channel 133
    !Time: Sat May 16 04:59:07 2009
    version 5.1(3)N1(1)
    interface san-port-channel 133
      channel mode active
      switchport mode F
      switchport trunk mode off
    Changed it as you suggested...
    Followed the order of operations for "no shut"
    Nexus FC -> Nexus SAN-PC -> FI FC -> FI SAN-PC.
    Didn't work:
    NX5KA(config-if)# show san-port-channel summary
    U-Up D-Down B-Hot-standby S-Suspended I-Individual link
    summary header
    Group  Port-      Type    Protocol               Member Ports
           Channel
    133    San-po133  FC      PCP      (D)  FC       fc2/15(D)    fc2/16(D)
    NX5KA(config-if)#
    Here is the output as you requested:
    NX5KA(config-if)# show int san-port-channel 133
    san-port-channel 133 is down (No operational members)
        Hardware is Fibre Channel
        Port WWN is 24:85:00:2a:6a:5a:81:00
        Admin port mode is F, trunk mode is off
        snmp link state traps are enabled
        Port vsan is 133
        1 minute input rate 1256 bits/sec, 157 bytes/sec, 0 frames/sec
        1 minute output rate 248 bits/sec, 31 bytes/sec, 0 frames/sec
          3966 frames input, 615568 bytes
            0 discards, 0 errors
            0 CRC,  0 unknown class
            0 too long, 0 too short
          2956 frames output, 143624 bytes
            0 discards, 0 errors
          46 input OLS, 41 LRR, 73 NOS, 0 loop inits
          257 output OLS, 189 LRR, 219 NOS, 0 loop inits
        last clearing of "show interface" counters never
        Member[1] : fc2/15
        Member[2] : fc2/16
    NX5KA(config-if)#
    NX5KA(config-if)# show int brief
    Interface  Vsan   Admin  Admin   Status          SFP    Oper  Oper   Port
                      Mode   Trunk                          Mode  Speed  Channel
                             Mode                                 (Gbps)
    fc2/13     1      auto   on      sfpAbsent        --     --           --
    fc2/14     1      auto   on      sfpAbsent        --     --           --
    fc2/15     133    F      off     init             swl    --           133
    fc2/16     133    F      off     init             swl    --           133

  • Determine NIF port used by VIF when configured in a port-channel

    I have recently just watched an excellent Cisco Live video on UCS performance troubleshooting which demonstrated how to trace network traffic within Cisco UCS. The speaker made a comment though, in order to determine which NIF is used by a VIF when port-channels are used between the FEX and FI there are different commands to run. Have to review the hash result or something he said. Unfortunately he never went into what these commands were.
    So when we have veths pinned to port-channels instead of HIFs and NIFs, what commands will show which path is being used?

    Duplicate of https://supportforums.cisco.com/discussion/12313436/determine-nif-port-used-vif-when-configured-port-channel

  • Port-channel Problem between Fabric Interconnect and N7K vPC

    Dear all,
    I have a problem with Port-channel Uplink between Fabric Interconnect with N7K using vPC
    This is my network topology for UCS Deployment
    In N7K I has configured vPC for red link and green link, at Fabric Interconnect A I has configured Port-Channel with member is Port 1 and Port 2, uplink is red link. At Fabric Interconnect B, I has configured Port-Channel with member is Port 1 and Port 2, uplink is green link.
    The show interface port-channel on N7K is good, every port-channel is up and have all member. But At Fabric Interconnnect, when I see on UCS Manager, the status of Port-Channel on Fabic A and Fabric B is fault with Additional Info: No operational member. Although all link is link up and I has status of Port-Channel is enable on UCS Manager. When I see the Properties of Port 1, Port 2 on Port-channel, I see the membership status is : individual. This mean port-channel is not up and no membership in this configuration. I want to using port-channel for load balance and plus more bandwidth for uplink to 20Gig. I don't understand why ?
    Please help me resolve this problem, I has send the capture screen of UCS Manager when I show status of Port-channel and Port-member in port-channel in attach items.
    Anyone can help me to resolve this, thanks you very much. Please reference attach items for more detail about fault.
    Thanks,
    Trung.

    Thanks Matthew very much,
    I has resolved this problem. The reason of problem is miss match protocol of port-channel between N7K and Fabric Interconnect. The Fabric Interconnect always use LACP protocol, but N7K using Port-channel mode on, that why the port-channel failed. I has configured LACP for port-channel in N7K, it has resolved the problems.
    Thanks,
    Trung.

  • Fabric Port Channel

    Hello,
    Once in production, when adding cables in a Fabric PortChannel between an IOM and a FI, ¿is it needed to re-ack the chassis? (so that, we'll have downtime of the whole chassis). Or rather, as it is a Port-Channel the cables are detected automatically, so that it is not needed to re-ack, and so there's no downtime at all...which one is the correct statement?
    Thanks,

    Hello,
    Let us consider following scenario on adding or removing links to existing deployment.
    Initial deployment
    UCSM 2.0, FI 62XX ,2208 IOM and 2 physical links with port channel configuration ( 2 link discovery policy )
    Change
    1) If additional links are added and if they need to be utilized and part of port channel, we need to re-ack the chassis.
    2) If a link goes down,traffic is distributed across other links in port channel and does not require re-ack. Parameters like bandwidth, VIF ports that are calculated based on initial configuration remains the same.
    3) If we physically remove the additional links between IOM / FI, re-acknowledment would create port-channel with original two links.Failure to re-ack will create over subscription ( bandwidth, available VIF ports ) of the network links.Re-ack is not mandatory but it creates appropriate configuration that matches required design criteria.
    Caution
    Adding or removing links  from a fabric port channel is disruptive and may affect the available amount of VIF namespace.
    http://www.cisco.com/en/US/docs/unified_computing/ucs/sw/gui/config/guide/2.0/b_UCSM_GUI_Configuration_Guide_2_0_chapter_0101.html#concept_5D3D88341BFB43468B62B5A77876C67B
    Padma

  • Migrate network segment to vlan routing with dlsw+

    Currently, the dlsw are terminated on the core router which has token ring interface. The rest of the network are segmented using ethernet interface on the core router.
    I need to migrate the network segment on the core router to cat6509 which will run inter-vlan routing.
    My concern is when I move down the bridge group from the router ethernet, any issue will arise?
    core router core router
    | |
    cat6509--------cat6509

    Hi,
    My HQ router running SRB/TB to allow ethernet segment at HQ router to access IBM host. There is an active dlsw peer to BR1 and backup peer to BR2.
    L1 and L2 are links between gigabit interface to routed port at core switch which running bridge group 1.
    CS2 will be the root for vlan 20,40,200. CS1 will be the root for vlan 10,30,100.
    L3 and L4 are trunk link to CS1 and CS2. AS1 is connected to DS1 on a port assigned to VLAN200. SNA client is on vlan 200.
    Vlan 20,40,200 are assigned to bridge group 1.
    For normal operation, SNA client establish circuit to the host. From CS1, I can see host mac address learn through bridge which is from gigabit interface connected to BR1. From CS2, I can see the host mac address learn through port channel.
    When L4 link down, the circuit still maintain with interruption. This time CS2 does not display any host mac address due DS1 will forward vlan 200 to CS1. The SNA traffic will go direct to BR1.
    During L4 recover ( meaning reconnect back the lost connection), I can see host mac address learn through vlan 20,40,200.
    After the mac aging, all mac address disappear and I can’t establish any SNA session. What could be the problem for this?

  • MDS9513 Add ISL to Port Channel problem.

    Hi Experts,
    I have a problem when add a new ISL to an existing Port Channel config.
    The ISL port is up state and correctly configured like another ports in port channel.
    Looks bellow the error:
    MDS1300M6A# show port-channel summary
    Interface                 Total Ports        Oper Ports        First Oper Port
    port-channel 1                 4                 4                  fc12/48
    port-channel 2                 2                 2                  fc6/47
    MDS1300M6A# show port-channel database
    port-channel 1
        Administrative channel mode is active
        Operational channel mode is active
        Last membership update failed: port not compatible [Resources Unavailable]
        First operational port is fc12/48
        4 ports in total, 4 ports up
        Ports:   fc12/48  [up] *
                 fc10/48  [up]
                 fc11/48  [up]
                 fc9/48   [up]
    Anyone seen this?
    Tks
    Wellington

    That did the trick - specifically setting the port channel to rate-mode shared.  Certainly solved the problem as far as getting all the deisred ports up in the channel, but where I still have a knowledge gap is the operational difference between dedicated and shared.  Are there any Cisco docs (beyond the command reference guide to toggle the feature) that explains why you'd choose one versus the other, and what it means from a design perspective?
    On a different note, while I'm no expert, here's some background to consider for others who may encounter the same issue (whether on UCS or a Nexus 5K).  I  (and our network team) come from an IOS background, so while the IOS "parts" of NX-OS are pretty familiar, the SAN "parts" of NX-OS are a little new.  We're also more CLI oriented, and while not impossible to configure via CLI, in our environment, the GUI for UCS seems to be more popular across the board - and we're still learning that piece as well.
    Our storage team is very familiar with SAN-OS, so they're very comfortable with the SAN "parts" of NX-OS.  But, they're very used to configuring the MDS switches via the GUI, which is what got us off track a bit.  In our scenario, creating a SAN port channel on the MDS via the GUI didn't give us the option for setting "switchport rate-mode shared"  Not saying it's not there in the GUI, but we certainly couldn't find it.
    Long story short, if the configuration of the SAN port channel on the MDS is in question, check it via the CLI and make any necessary changes there as a quick workaroud.

  • How to configure a port channel with VLAN trunking (and make it work..)

    We're trying to configure a port channel group with trunked ports to connect a NetApp HA pair. We want to create two data LIFs and connect them to the switch stack.  We are trying to create 2 data lifs, one for cifs and one for nfs that are on different vlans.
    We want the same ports to be able to allow multiple vlans to communicate. (trunked)
    These data lifs should be able to fail over to different nodes in the HA pair and still be able to communicate on the network.
    What this means is that we have to connect 4 ports each for each node in the NetApp HA Pair to the switches and create a port channel of some type that allows for trunked vlans. When we configure the ports, the configuration is as follows (below):
    We are only able to configure an IP on one of the vlans.
    When we configure an IP from another vlan for the data lif, it does not respond to a ping.
    Does anyone have any idea what I'm doing wrong on the Cisco switch?
    interface GigabitEthernet4/0/12
    description Netapp2-e0a
    switchport trunk encapsulation dot1q
    switchport trunk allowed vlan 10,20,511,519
    channel-protocol lacp
    channel-group 20 mode active
    end
    interface GigabitEthernet4/0/13
    description Netapp2-e0c
    switchport trunk encapsulation dot1q
    switchport trunk allowed vlan 10,20,511,519
    channel-protocol lacp
    channel-group 20 mode active
    end
    interface GigabitEthernet6/0/12
    description Netapp2-e0b
    switchport trunk encapsulation dot1q
    switchport trunk allowed vlan 10,20,511,519
    channel-protocol lacp
    channel-group 20 mode active
    end
    interface GigabitEthernet6/0/13
    description Netapp2-e0d
    switchport trunk encapsulation dot1q
    switchport trunk allowed vlan 10,20,511,519
    channel-protocol lacp
    channel-group 20 mode active
    end
    interface Port-channel20
    description Netapp2-NFS
    switchport trunk encapsulation dot1q
    switchport trunk allowed vlan 10,20,511,519
    spanning-tree portfast
    spanning-tree bpduguard enable
    end

    Our problem was fixed by the storage people.  They changed the server end to trunk, and the encapsulation / etherchannel.
    I like all the suggestions, and they probably helped out with the configuration getting this to work.
    Thanks!
    interface Port-channel20
    description Netapp2-NFS
    switchport trunk encapsulation dot1q
    switchport trunk allowed vlan 10,20,511,519
    switchport mode trunk
    interface GigabitEthernet4/0/12
    switchport trunk encapsulation dot1q
    switchport trunk allowed vlan 10,20,511,519
    switchport mode trunk
    channel-protocol lacp
    channel-group 20 mode active
    interface GigabitEthernet4/0/13
    switchport trunk encapsulation dot1q
    switchport trunk allowed vlan 10,20,511,519
    switchport mode trunk
    channel-protocol lacp
    channel-group 20 mode active
    interface GigabitEthernet6/0/12
    switchport trunk encapsulation dot1q
    switchport trunk allowed vlan 10,20,511,519
    switchport mode trunk
    channel-protocol lacp
    channel-group 20 mode active
    interface GigabitEthernet6/0/13
    switchport trunk encapsulation dot1q
    switchport trunk allowed vlan 10,20,511,519
    switchport mode trunk
    channel-protocol lacp
    channel-group 20 mode active