Unexpected error [0x8CFB0B0] while executing command 'Get-LinkedRoleGroupForLogonUser'

Hi Experts....
I am facing a weired error when connecting to Exchange On-Premises...
I have 2 virtual machines in Virtual-Box .On 1st machine I has installed Active Directory..
On 2nd machine I have to install Exchange Server.I have joined the second machine in the domain.
After Installing all the pre-requisites and updates for Exchange when I open the exchange management console I faced the following error....
Initialization Failed
The following error occurred when retreiving user information for 'ABC\Administrator':
Unexpected error [0x8CFB0B0] while executing command 'Get-LinkedRoleGroupForLogonUser'
Click here to Retry
Can anyone help me in this regard....!!!!
Thank You...!!!!

Hi,
From the error description, I recommend open C:\Program Files\Microsoft\Exchange Server\V14\RemoteScripts, check the ConsoleInitialize.ps1 file, find "function global:Get-LinkedRoleGroupForLogonUser()", here is the right file of this part for your reference.
foreach ($sid in $sids)
         try
           $accountName = $sid.Translate([System.Security.Principal.NTAccount]).Value
         catch
           continue
         if ($accountName -ne $null)
           foreach ($roleGroup in $allLinkedRoleGroups)
             if ([string]::Compare($roleGroup.LinkedGroup,$accountName,$True) -eq 0)
               $roleGroup
Hope it helps.
Best regards,
Amy
Amy Wang
TechNet Community Support

Similar Messages

  • App-V 5: Error encountered while executing command Mount-AppvClientPackage

    I am getting this error in which no Google search reveals anyone else as having reported it anywhere.  In fact, after having posted this, it was the only search result that came up with either of these two event ID's or errors.
    I am trying to sequence an in house application. It's a manual install. The application runs perfectly prior to creating the package so I am not sure what this "specified file" is that it can't find.  It says to refer to the AppV Client Event
    Log for more details. This event was *IN* the AppV Client Event Log and there was another event along side it.
    Event ID 9001
    Error encountered while executing command Mount-AppvClientPackage -PackageId eb77be98-bc44-45fd-a0e5-95e0c315808b -VersionId c5013ec7-0456-401b-b99e-d988d97bfa55. Error: Application Virtualization Service failed to complete requested operation. 
    Operation attempted: Mount Package. 
    Windows Error: 0x80070002 - The system cannot find the file specified
    Error module: Streaming Manager. Internal error detail: 74F0262C80070002. 
    Please consult AppV Client Event Log for more details.
    Event ID 14016
    The package {eb77be98-bc44-45fd-a0e5-95e0c315808b}
    version {c5013ec7-0456-401b-b99e-d988d97bfa55} could not be mounted
    because the network connection has been lost or is unavailable.  Check your network connection and try again.
    The network connection is still quite alive on the client and the firewall is disabled on the App-V server. I can still reach and view the xml file when browsing to the web service on the App-V server.  I can also run Sync-AppVPublishingServer from
    powershell without error.
    For more inside info on the app: 
    1. It is a manual install. A directory is simply copied to the hard drive manually.
    2. An ocx file gets registered from the Syswow64 directory.
    3. MySQL 5.1.13 client is installed.
    4. Shortcuts are created.
    5. A system DSN is created using C:\Windows\SysWOW64\odbcad32.exe
    6. The app runs perfectly on the sequencer prior to creating and publishing.
    UPDATE:
    Get-AppVClientPackage reveals this:
    PackageId            : eb77be98-bc44-45fd-a0e5-95e0c315808b
    VersionId            : c5013ec7-0456-401b-b99e-d988d97bfa55
    Name                 : Tietan
    Version              : 0.0.0.1
    Path                 : \\wuspappv01\appv1\TietanProd\Tietan.appv
    IsPublishedToUser    : True
    UserPending          : False
    IsPublishedGlobally  : False
    GlobalPending        : False
    InUse                : False
    InUseByCurrentUser   : False
    PackageSize          : 217155655
    PercentLoaded        : 0
    IsLoading            : False
    HasAssetIntelligence : True
    The path is accessible from the client server. I can see the file. It's there.

    Hello,
    If you execute get-appvclientpackage
    And then check what is the value for Path for the package you have an issue with.
    Most likely the error message means that the file in Path isn't reachable.
    As indicated here;
    The package {eb77be98-bc44-45fd-a0e5-95e0c315808b}
    version {c5013ec7-0456-401b-b99e-d988d97bfa55} could not be mounted
    because the network connection has been lost or is unavailable.  Check your network connection and try again.
    Nicke Källén | The Knack| Twitter:
    @Znackattack

  • Error while executing "" command Error type ACCESS VIOLATION Error Address: 0006898E Module name:gfsdesk.DLL

    Hi All,
    I'm using diadem from .net Program. While on the run I'm getting the following error.
    Error While executing "" Command
    Error type ACCESS VIOLATION
    Error Address: 0006898E
    Module name:gfsdesk.DLL
    Anyone have any idea why this is happening?
    regards,
    Swaroop

    Hi Swaroop,
    It would be helpful to better understand what your code really does. The information that you called DIAdem from your enviroenment is not yet sufficient to understand what the problem might be.
    Andreas

  • BAM Deployment error - Microsoft.BizTalk.Bam.Management.BamManagerException: The BAM deployment failed. --- Microsoft.BizTalk.Bam.Management.BamManagerException: Encountered error while executing command on SQL Server "ServerName".

    HI,
    I am getting below error while deploying BAM activity ...Pls help me resolve this issue.
    Microsoft.BizTalk.Bam.Management.BamManagerException: The BAM deployment failed. ---> Microsoft.BizTalk.Bam.Management.BamManagerException: Encountered error while executing command on SQL Server
    "ServerName". ---> System.Data.SqlClient.SqlException: An object or column name is missing or empty. For SELECT INTO statements, verify each column has a name. For other statements, look for empty alias names. Aliases defined as "" or
    [] are not allowed. Change the alias to a valid name.An object or column name is missing or empty. For SELECT INTO statements, verify each column has a name. For other statements, look for empty alias names. Aliases defined as "" or [] are not allowed.
    Change the alias to a valid name.An object or column name is missing or empty. For SELECT INTO statements, verify each column has a name. For other statements, look for empty alias names. Aliases defined as "" or [] are not allowed. Change the alias
    to a valid name.An object or column name is missing or empty. For SELECT INTO statements, verify each column has a name. For other statements, look for empty alias names. Aliases defined as "" or [] are not allowed. Change the alias to a valid name.An
    object or column name is missing or empty. For SELECT INTO statements, verify each column has a name. For other statements, look for empty alias names. Aliases defined as "" or [] are not allowed. Change the alias to a valid name.An object or column
    name is missing or empty. For SELECT INTO statements, verify each column has a name. For other statements, look for empty alias names. Aliases defined as "" or [] are not allowed. Change the alias to a valid name.An object or column name is missing
    or empty. For SELECT INTO statements, verify each column has a name. For other statements, look for empty alias names. Aliases defined as "" or [] are not allowed. Change the alias to a valid name.An object or column name is missing or empty. For
    SELECT INTO statements, verify each column has a name. For other statements, look for empty alias names. Aliases defined as "" or [] are not allowed. Change the alias to a valid name.An object or column name is missing or empty. For SELECT INTO statements,
    verify each column has a name. For other statements, look for empty alias names. Aliases defined as "" or [] are not allowed. Change the alias to a valid name.An object or column name is missing or empty. For SELECT INTO statements, verify each column
    has a name. For other statements, look for empty alias names. Aliases defined as "" or [] are not allowed. Change the alias to a valid name.An object or column name is missing or empty. For SELECT INTO statements, verify each column has a name. For
    other statements, look for empty alias names. Aliases defined as "" or [] are not allowed. Change the alias to a valid name.An object or column name is missing or empty. For SELECT INTO statements, verify each column has a name. For other statements,
    look for empty alias names. Aliases defined as "" or [] are not allowed. Change the alias to a valid name.   at System.Data.SqlClient.SqlConnection.OnError(SqlException exception, Boolean breakConnection, Action`1 wrapCloseInAction) 
     at System.Data.SqlClient.SqlInternalConnection.OnError(SqlException exception, Boolean breakConnection, Action`1 wrapCloseInAction)   at System.Data.SqlClient.TdsParser.ThrowExceptionAndWarning(TdsParserStateObject stateObj, Boolean callerHasConnectionLock,
    Boolean asyncClose)   at System.Data.SqlClient.TdsParser.TryRun(RunBehavior runBehavior, SqlCommand cmdHandler, SqlDataReader dataStream, BulkCopySimpleResultSet bulkCopyHandler, TdsParserStateObject stateObj, Boolean& dataReady)   at
    System.Data.SqlClient.SqlCommand.RunExecuteNonQueryTds(String methodName, Boolean async, Int32 timeout, Boolean asyncWrite)   at System.Data.SqlClient.SqlCommand.InternalExecuteNonQuery(TaskCompletionSource`1 completion, String methodName, Boolean
    sendToPipe, Int32 timeout, Boolean asyncWrite)   at System.Data.SqlClient.SqlCommand.ExecuteNonQuery()   at Microsoft.BizTalk.Bam.Management.SqlHelper.ExecuteBatches(String cmdText)   at Microsoft.BizTalk.Bam.Management.SqlHelper.ExecuteNonQuery(String
    cmdText, CommandType cmdType, Boolean inTransaction, Transaction transaction)   --- End of inner exception stack trace ---   at Microsoft.BizTalk.Bam.Management.SqlHelper.ExecuteNonQuery(String cmdText, CommandType cmdType, Boolean inTransaction,
    Transaction transaction)   at Microsoft.BizTalk.Bam.Management.ViewModule.Create(XmlDocument defXmlDoc)   at Microsoft.BizTalk.Bam.Management.WorkerModule.DispatchOperation(OperationType operation, XmlDocument defXmlDoc)   at
    Microsoft.BizTalk.Bam.Management.BamManager.ProcessOneBamArtifactType(BamArtifactType bamArtifact, OperationType operation)   at Microsoft.BizTalk.Bam.Management.BamManager.ManageInfrastructure(OperationType operation)   at Microsoft.BizTalk.Bam.Management.BamManager.Deploy() 
     --- End of inner exception stack trace ---   at Microsoft.BizTalk.Bam.Management.BamManager.Deploy()   at Microsoft.BizTalk.Bam.Management.BamManagementUtility.BamManagementUtility.HandleDeployAll()   at Microsoft.BizTalk.Bam.Management.BamManagementUtility.BamManagementUtility.DispatchCommand() 
     at Microsoft.BizTalk.Bam.Management.BamManagementUtility.BamManagementUtility.Run()   at Microsoft.BizTalk.Bam.Management.BamManagementUtility.BamManagementUtility.Main(String[] args)

    Your View Name, OLAP Cube Name and certain other restrictions listed @http://msdn.microsoft.com/en-us/library/aa561577.aspx
    Please review your BAM Definitons.
    Regards.

  • Diadem runtime error while executing command "SchemeMeasStar"

    Hello:
    I used DIAdem9.0 and DAQCard6062E to acquire 16 channel data. I collected 65536 data for every channel. Whereas After the data acquisition stopped, an Error Message would poped up, but the data is still stored in data portal. the Error is like follows:
    -Error- DIAdem
    Runtime Error While Executing Command "SchemeMeasStar"
    Error Type: UNKNOWN
    Error Address:00001720
    Module Name:GFSBase.Dll
    Would you like to give me some suggestions?
    thanks very much
    jing

    Dear MarcusP:
    Thank you very much.
    your solution really works. The attached is the detailed information of the problem. Would you like to tell me more about the prolem and how to solve the problem thoroughly.
    Thank you very much.
    yours
    Jing
    Attachments:
    DIAdem_Error.doc ‏305 KB

  • [INS-08109] Unexpected error occurred while validating inputs at state 'get

    Facing that on a windows 2003 server on installing 11gR2 on an installed 11.1.0.6
    [INS-08109] Unexpected error occurred while validating inputs at state 'getOCMDetails'.
    that's in the first step on the installer

    Very stupid installer !
    I've omitted my email, then pressed no in the next message, it passed that step!

  • Error during Portal Setup: An error occurred while executing a custom action:_GrantLocalPermissionsToWCSAccount

    Error:
    Configure Portal Setup
    An error occurred while executing a custom action:_GrantLocalPermissionsToWCSAccount.11EE91AB_EABF_48A6_9973_4DCD73190AC6
    This upgrade attempt has failed before permanent modifications were made. Upgrade has successfully rolled back to the original state of the system. Once the correction are made, you can retry upgrade for this role.
    Errors in the Log:
    MSI (s) (38:14) [21:30:36:094]: NOTE: custom action _GrantLocalPermissionsToWCSAccount.11EE91AB_EABF_48A6_9973_4DCD73190AC6 unexpectedly closed the hInstall handle (type MSIHANDLE) provided to it. The custom action should be fixed to not close that handle.
    CustomAction _GrantLocalPermissionsToWCSAccount.11EE91AB_EABF_48A6_9973_4DCD73190AC6 returned actual error code 1603 (note this may not be 100% accurate if translation happened inside sandbox)
    MSI (s) (38:94) [21:30:36:115]: User policy value 'DisableRollback' is 0
    MSI (s) (38:14) [21:30:36:094]: NOTE: custom action _GrantLocalPermissionsToWCSAccount.11EE91AB_EABF_48A6_9973_4DCD73190AC6 unexpectedly closed the hInstall handle (type MSIHANDLE) provided to it. The custom action should be fixed to not close that handle.
    CustomAction _GrantLocalPermissionsToWCSAccount.11EE91AB_EABF_48A6_9973_4DCD73190AC6 returned actual error code 1603 (note this may not be 100% accurate if translation happened inside sandbox)
    MSI (s) (38:94) [21:30:36:115]: User policy value 'DisableRollback' is 0
    I cannot get past this error. I am running Sharepoint Foundation 2010 with Sp1. This is on a Windows Server 2008 R2 Server +Sp1.
    Any ideas?
    David Baur

    I finally figured this out, The issue was that I had put in the Self Service Portal Computer Name and Service account into the Service Manager SQL as SysAdmin, once I removed it flew through just fine.
    David Baur

  • An unknown error occurred while executing the PowerShell script:

    Hello all,
    Not the most descriptive title, granted. I'm hoping this may prompt the next version toprovide additional valuable content.
    Kindly requesting any help on this problem. I'm running VMM 2012 R2 version 3.2.7668
    When I try to look at properties of an existing Private Cloud, I get this error, only if I "look" at certain attributes. If I stay away from the specific attributes, everything is hunky dory. For reasons unknown, after I get this error, I have
    to exit and go back into VMM in order to get anything else to run.
    The text in the error dialogue box is not entirely applicable because I was connected to the VMM server and will connect again, when I exit/relaunch.
    An unknown error occurred while executing the PowerShell script:
    The connection to the VMM management server scvmm2.mmmmmm.com was lost.
    Ensure that scvmm2.mmmmmm.com is online and that you can access the server remotely from your computer. Then connect to scvmm2.mmmmmm.com and try the command again using the new connection. Or, you can ensure that the Virtual Machine Manager service is started
    on scvmm2.mmmmmm.com. Then connect to scvmm2.mmmmmm.com and try the command again using the new connection. If the command fails again because of a connection failure, restart the Virtual Manager service and then try the operation again.
    Try the operation again. If the issue persists, contact Microsoft Help and Support.
    ID: 27235
    This is what I get in Events
    Warning 4/9/2015 3:27:04 PM PowerShell (Microsoft-Windows-PowerShell) 4100 Executing Pipeline
    Log Name:      Microsoft-Windows-PowerShell/Operational
    Source:        Microsoft-Windows-PowerShell
    Date:          4/9/2015 3:27:04 PM
    Event ID:      4100
    Task Category: Executing Pipeline
    Level:         Warning
    Keywords:      None
    User:          mmmmmm\paufra
    Computer:      tools-francis.mmmmmm.com
    Description:
    Error Message = The connection to the VMM management server scvmm2.mmmmmm.com was lost. (Error ID: 1610)
    Ensure that scvmm2.mmmmmm.com is online and that you can access the server remotely from your computer. Then connect to scvmm2.mmmmmm.com and try the command again using the new connection. Or, you can ensure that the Virtual Machine Manager service is started
    on scvmm2.mmmmmm.com. Then connect to scvmm2.mmmmmm.com and try the command again using the new connection. If the command fails again because of a connection failure, restart the Virtual Manager service and then try the operation again.
    Fully Qualified Error ID = 1610,Microsoft.SystemCenter.VirtualMachineManager.Cmdlets.GetSCReplicationGroupCmdlet
    Recommended Action = Ensure that scvmm2.mmmmmm.com is online and that you can access the server remotely from your computer. Then connect to scvmm2.mmmmmm.com and try the command again using the new connection. Or, you can ensure that the Virtual Machine Manager
    service is started on scvmm2.mmmmmm.com. Then connect to scvmm2.mmmmmm.com and try the command again using the new connection. If the command fails again because of a connection failure, restart the Virtual Manager service and then try the operation again.
    Context:
            Severity = Warning
            Host Name = Default Host
            Host Version = 4.0
            Host ID = 94963cd4-5979-4786-9da2-c8814de8c7c3
            Host Application = C:\Program Files\Microsoft System Center 2012 R2\Virtual Machine Manager\Bin\VmmAdminUI.exe
            Engine Version = 4.0
            Runspace ID = 359d7a46-3752-4929-8c09-0de4152d10e4
            Pipeline ID = 16
            Command Name = Get-SCReplicationGroup
            Command Type = Cmdlet
            Script Name =
            Command Path =
            Sequence Number = 91
            User = mmmmmm\paufra
            Shell ID = Microsoft.PowerShell
    User Data:
    Event Xml:
    <Event xmlns="http://schemas.microsoft.com/win/2004/08/events/event">
      <System>
        <Provider Name="Microsoft-Windows-PowerShell" Guid="{A0C1853B-5C40-4B15-8766-3CF1C58F985A}" />
        <EventID>4100</EventID>
        <Version>1</Version>
        <Level>3</Level>
        <Task>106</Task>
        <Opcode>19</Opcode>
        <Keywords>0x0</Keywords>
        <TimeCreated SystemTime="2015-04-09T22:27:04.993655700Z" />
        <EventRecordID>285</EventRecordID>
        <Correlation ActivityID="{48059811-1A63-41E1-9057-7498D0E4FC20}" />
        <Execution ProcessID="2344" ThreadID="4076" />
        <Channel>Microsoft-Windows-PowerShell/Operational</Channel>
        <Computer>tools-francis.mmmmmm.com</Computer>
        <Security UserID="S-1-5-21-4008432563-1984933819-4238309236-2721" />
      </System>
      <EventData>
        <Data Name="ContextInfo">        Severity = Warning
            Host Name = Default Host
            Host Version = 4.0
            Host ID = 94963cd4-5979-4786-9da2-c8814de8c7c3
            Host Application = C:\Program Files\Microsoft System Center 2012 R2\Virtual Machine Manager\Bin\VmmAdminUI.exe
            Engine Version = 4.0
            Runspace ID = 359d7a46-3752-4929-8c09-0de4152d10e4
            Pipeline ID = 16
            Command Name = Get-SCReplicationGroup
            Command Type = Cmdlet
            Script Name =
            Command Path =
            Sequence Number = 91
            User = mmmmmm\paufra
            Shell ID = Microsoft.PowerShell
    </Data>
        <Data Name="UserData">
        </Data>
        <Data Name="Payload">Error Message = The connection to the VMM management server scvmm2.mmmmmm.com was lost. (Error ID: 1610)
    Ensure that scvmm2.mmmmmm.com is online and that you can access the server remotely from your computer. Then connect to scvmm2.mmmmmm.com and try the command again using the new connection. Or, you can ensure that the Virtual Machine Manager service is started
    on scvmm2.mmmmmm.com. Then connect to scvmm2.mmmmmm.com and try the command again using the new connection. If the command fails again because of a connection failure, restart the Virtual Manager service and then try the operation again.
    Fully Qualified Error ID = 1610,Microsoft.SystemCenter.VirtualMachineManager.Cmdlets.GetSCReplicationGroupCmdlet
    Recommended Action = Ensure that scvmm2.mmmmmm.com is online and that you can access the server remotely from your computer. Then connect to scvmm2.mmmmmm.com and try the command again using the new connection. Or, you can ensure that the Virtual Machine Manager
    service is started on scvmm2.mmmmmm.com. Then connect to scvmm2.mmmmmm.com and try the command again using the new connection. If the command fails again because of a connection failure, restart the Virtual Manager service and then try the operation again.
    </Data>
      </EventData>
    </Event>

    Hi Sir,
    First , please try to run the VMM configuration analyzer on that computer :
    http://www.microsoft.com/en-us/download/details.aspx?id=41555
    In addition , please try to use "VMMTrace" mentioned in following article to collect trace log and find some useful information :
    http://blogs.technet.com/b/jonjor/archive/2011/01/07/vmmtrace-simplified-scvmm-tracing.aspx
    Best Regards,
    Elton Ji
    Please remember to mark the replies as answers if they help and unmark them if they provide no help. If you have feedback for TechNet Subscriber Support, contact [email protected] .

  • An unexpected error occurred while the job was running. (ID 104 Details: The parameter is incorrect (0x80070057))

    We are using DPM Version: 4.1.3465.0 with System Center 2012 Service Pack 1 to back up VMs in our Hyper V Cluster. We have a total of 37 VMs with a combination of 2008r2 servers and 2012 servers. One of our 2012 servers will not backup, and we consistently
    get the message "An unexpected error occurred while the job was running. (ID 104 Details: The parameter is incorrect (0x80070057))". I have seen this error message when I Googled it, but cannot get past it. I have deleted the Protection Group and
    data and tried to re-create, but get the same errors. I also thought the the server might be mis-reporting the data size, but I expanded that to cover the replication data. I have also tried to perform consistancy checks multiple times with no luck. I have
    not seen a difinitive answer from my Google searches, so was hopeful someone has seen this also, and have had success in resolving. Currently this server has no backup recovery points, so I am worried if it does crash. I think I have the rollups installed
    as well.

    Hi Kelly,
    does the issue still persists?

  • "An unexpected error occurred while creating a custom installer."

    All;
    I—and I've seen several others in older posts—have been reported received the error "An unexpected error occurred while creating a custom installer" while attampting to build a customer ARD client installer.  My guess is that this is do to a issue related to 10.8.X (10.8.4, in my case) based console Mac but I cannot confirm this. I have verified that there are no outstanding OS, client or application updates or hot fixes, as well.
    Has anyone built an successful installer from Mountain Lion-installed Mac?  Is there any know workarounds?
    Thanks in advance, for any help. 

    Have the exact same problem.
    iMac running 10.8.4
    Got through the steps of creating a custom client installer.
    if I choose not to customize and just save an installer I don't get the error but it creates a file of Zero bytes in size.
    If I chose to configure, when I try to save I get:
    An unexpected error occurred while creating a custom installer. Please try again....
    Console log reports:
    9/1/13 12:32:29.603 AM Remote Desktop[1306]: open on /private/tmp/RemoteDesktopClientInstaller_HEATyAJ5CR/extracted/RemoteDesktopCli ent.pkg/Scripts/RemoteDesktopClient.pkg: No such file or directory
    I have tried to save this in several location, with no effect on the error or the information logged, with the exception of the name of the temp directory that DOES contains the file (zero bytes):
    RemoteDesktopClient.pkg
    Need help with this someone...!
    APPLE...I JUST purchase this Applciation for $80.....it just flat out does not work....

  • SCSM2012 Beta installation problem: An error occurred while executing a custom action:_PopulateUserRoles

    I'm installing the SCSM2012 Management Server
    component on a SQL dev box.  During the installation, the very last step (Import Management Packs) fails with this error:
    An error occurred while executing a custom action:_PopulateUserRoles
    This upgrade attempt has failed before permanent modifications were made. Upgrade has successfully rolled back to the original state of the system. Once the correction are made, you can retry upgrade for this role.
    I've already verified that the account I'm logged in with has SA access to the SQL database.  Windows 2008 R2 firewall is turned off.....
    Has anybody else run into this problem?

    I don't see anything indicative in the setup log.  The setup seems to get all the way to the part where it installs the management packs.  Then right after that is when the installation fails and it rolls back.
    From the setup log, towards the end:
    Property(S): ACTIONSUSER = NETWORK SERVICE
    Property(S): ACTIONSDOMAIN = NT AUTHORITY
    Property(S): ACTIONSUSER_FOR_DB = NETWORK SERVICE
    Property(S): ACTIONSDOMAIN_FOR_DB = NT AUTHORITY
    Property(S): SOURCEDIR = C:\SCSM\SCSM2012_Beta\Setup\Server\
    Property(S): SourcedirProduct = {295201AE-EAB6-416C-8252-7C065243EF55}
    Property(S): ProductToBeRegistered = 1
    MSI (s) (9C:54) [17:33:22:951]: Note: 1: 1708
    MSI (s) (9C:54) [17:33:22:951]: Product: Microsoft System Center Service Manager 2012 -- Installation failed.
    MSI (s) (9C:54) [17:33:22:959]: Windows Installer installed the product. Product Name: Microsoft System Center Service Manager 2012. Product Version: 7.5.1354.0. Product Language: 0. Manufacturer: Microsoft Corporation. Installation success or error status:
    1603.
    MSI (s) (9C:54) [17:33:23:010]: Deferring clean up of packages/files, if any exist
    MSI (s) (9C:54) [17:33:23:013]: MainEngineThread is returning 1603
    MSI (s) (9C:20) [17:33:23:061]: RESTART MANAGER: Session closed.
    MSI (s) (9C:20) [17:33:23:061]: No System Restore sequence number for this installation.
    === Logging stopped: 11/7/2011  17:33:22 ===
    MSI (s) (9C:20) [17:33:23:065]: User policy value 'DisableRollback' is 0
    MSI (s) (9C:20) [17:33:23:065]: Machine policy value 'DisableRollback' is 0
    MSI (s) (9C:20) [17:33:23:065]: Incrementing counter to disable shutdown. Counter after increment: 0
    MSI (s) (9C:20) [17:33:23:065]: Note: 1: 1402 2: HKEY_LOCAL_MACHINE\Software\Microsoft\Windows\CurrentVersion\Installer\Rollback\Scripts 3: 2
    MSI (s) (9C:20) [17:33:23:066]: Note: 1: 1402 2: HKEY_LOCAL_MACHINE\Software\Microsoft\Windows\CurrentVersion\Installer\Rollback\Scripts 3: 2
    MSI (s) (9C:20) [17:33:23:067]: Decrementing counter to disable shutdown. If counter >= 0, shutdown will be denied.  Counter after decrement: -1
    MSI (s) (9C:20) [17:33:23:067]: Restoring environment variables
    MSI (s) (9C:20) [17:33:23:089]: Destroying RemoteAPI object.
    MSI (s) (9C:28) [17:33:23:089]: Custom Action Manager thread ending.
    MSI (c) (C8:B4) [17:33:23:144]: Decrementing counter to disable shutdown. If counter >= 0, shutdown will be denied.  Counter after decrement: -1
    MSI (c) (C8:B4) [17:33:23:175]: MainEngineThread is returning 1603
    === Verbose logging stopped: 11/7/2011  17:33:23 ===

  • INS-08109 Unexpected error occurred while validating inputs at state nodeselection page

    Scenerio: We have 4 node 11gr2 RAC cluster and Trying to install RAC Database software only on two nodes
    Getting warning on run Installer Page INS-08109 Unexpected error occurred while validating inputs at state nodeselection page while selecting two nodes out of four and even after confirming it comes back to same screen ....
    Example ... RAC node A,B,C,D  and clusterware is up and running on all four nodes .....
    Trying to Install RAC database on node C,D ... Getting INS-08109 Unexpected error occurred  while selecting C,D  Node out of Four nodes ...A,B,C,D

    Very stupid installer !
    I've omitted my email, then pressed no in the next message, it passed that step!

  • XL reporter error occurred while executing report! Rows: 25203 Columns: 30

    An error occurred while executing report! Rows: 25203 Columns: 30 Unspecified error
    One user gets this error when trying to run a custom XL report. It works for other users(on different PCs). The user can run other XL reports successfully.

    Hello  pls
    follow below procedure
    start->my computer>cdrive>program files >sap>sap business one> remove these two files 1).AddOnsInstall.sbo and 2).AddOnsLocalRegistration.sbo and clear all ur %temp%Files,prefetch,recent files and restart and open sap then u will get connected to xl reporter add on. and u will not get any errors
    regards
    Jenny

  • An error occurred while executing a custom action:_PopulateUserRoles

    I am trying to install Service Manager 2012 RTM onto a brand new server 2008r2. The purpose is to replace the other Data Management server that is giving me problems upgrading to service pack1. I go through the setup and connect to the SQL server and
    the database that has my existing DM. I am using the same credentials and everything is the same. It goes all the way to the end and I get an error :
    An error occurred while executing a custom action:_PopulateUserRoles
    This upgrade attempt has failed before permanent modifications were made. Upgrade has successfully rolled back to the original state of the system. Once the correction are made, you can retry upgrade for this roll

    After this error, I reran setup and used the domain admin account instead of the Service Manager Admins group I created in AD. The  error did not happen again, but I did get the "Setup cannot complete - RollbackCleanup"
    error. This was fixed by following this link: "http://www.cireson.com/scsm/scsm-an-error-occurred/" and this MS article: "http://support.microsoft.com/kb/922918/en-us".
    These are the steps (I had to create the DWORD 32 bit):
    Click Start, click Run, type regedit, and then click
    OK.
    Locate and then click the following registry subkey:
    HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control
    In the right pane, locate the ServicesPipeTimeout entry.
    Note  If the ServicesPipeTimeout entry does not exist, you must create it. To do this, follow these steps:
    On the Edit menu, point to
    New, and then click DWORD Value.
    Type ServicesPipeTimeout, and then press ENTER.
    Right-click ServicesPipeTimeout, and then click Modify.
    Click Decimal, type 60000, and then click
    OK.
    This value represents the time in milliseconds before a service times out.
    Restart the computer.
    Hope this helps!
    BR,
    Robert
    Robert

  • An unexpected error occurred while the job was running. (ID: 104)

    I'm getting this error in the event logs when trying to run a consistency check / sync with one of our file servers.
    This server was working fine, but w needed to migrate the data to a new partition (GPT) to allow it to expand past the 2TB limit of MBR partitions.  I added a new 3TB disk migrated the data and changed the drive letter to what the old partition was
    prior.  Since then we seem to get this error.
    I have installed the update roll up on both the server and the agent side.  I have also removed the server from the protection group then re-added it.  I've also removed and reinstalled the agent on the file server.
    Any help is appreciated!  Here's the full error from the DPM server:
    The replica of E:\ on server is inconsistent with the protected data source. All protection activities for data source will fail until the replica is synchronized with consistency check. (ID: 3106)
    An unexpected error occurred while the job was running. (ID: 104)

    Server Version is Windows 2012 R2 STD.  DPM is 4.2.1235.0 (DPM 2012 R2).  I expanded the production file server.  All that server does is host up file shares.
    I suspected the fact that I created a new volume and changed drive letter back to the original to be the source cause of the issue.  What I ended up doing is blowing away the backups from this server on disk and re-adding it to the protection group. 
    It now runs much longer, but still times out at random with the error mentioned above.
    Vijay:  The error was copied from Event Viewer.  Not sure what else you require?  Event ID is 3106 from DPM-EM.
    The DPM logs say:
    Affected area: E:\
    Occurred since: 2015-01-05 2:04:38 AM
    Description: The replica of Volume E:\ on servername is inconsistent with the protected data source. All protection activities for data source will fail until the replica is synchronized with consistency check. You can recover data from existing recovery
    points, but new recovery points cannot be created until the replica is consistent.
    For SharePoint farm, recovery points will continue getting created with the databases that are consistent. To backup inconsistent databases, run a consistency check on the farm. (ID 3106)
     An unexpected error occurred while the job was running. (ID 104 Details: The semaphore timeout period has expired (0x80070079))
    Date inactivated: 2015-01-05 7:03:04 AM
    Recommended action: No action is required because this alert is inactive.
    Affected area: E:\
    Occurred since: 2015-01-05 2:04:38 AM
    Description: The replica of Volume E:\ on servername is inconsistent with the protected data source. All protection activities for data source will fail until the replica is synchronized with consistency check. You can recover data from existing
    recovery points, but new recovery points cannot be created until the replica is consistent.
    For SharePoint farm, recovery points will continue getting created with the databases that are consistent. To backup inconsistent databases, run a consistency check on the farm. (ID 3106)
     An unexpected error occurred while the job was running. (ID 104 Details: The semaphore timeout period has expired (0x80070079))

Maybe you are looking for

  • Issue while loading crystal Report.

    Hi , Crystal report is getting loaded properly in the VS Viewer for Crystal report when we preview the report but when the same report is being loaded through application then following errors are being displayed: 1) "Object reference not set to an i

  • Usage of intensity in BOX command in Scripts

    Hi all How to set INTENSITY property to a particular box? Except this syntax, BOX XPOS 44 CH YPOS 2 CH HEIGHT '8.2' CH WIDTH 29 CH FRAME 3 TW iINTENSITY 12. Because this statement is not fitting in a line. Inorder to fit this statement in a single li

  • HT201250 backup not working

    cannot get time machine to work

  • Disable "Payment term" field in VA01

    Dear Gurus,        I need to disable payment term filed in VA01 tcode for particular company code and to specific users, I can do it by company code using User Exit, but how do I control if it is specific to particular users.       If cannot do it us

  • How do I run 2 or more VIs simultaneously?

    Hi. I'm trying to create an application, where I need two or more VIs running at the same time. My problem is that when I call a subVi, my main VI is frozen until the subVI finishes. Does anyone know how to programmatically call/open/run a VI or subV