Upgrade From 4.6B TO ECC 5.0

Hi,
I am involved in a upgrade project from 4.6B to ECC 5.0 as a Technical Consultant. Kindly let me know if you any document
you can send it to:  [email protected]
thanks,
-suresh

e.c.c 6.0 to follow the unicode rules.
ABAP Development under Unicode
Prior to Unicode the length of a character was exactly one byte, allowing implicit typecasts or memory-layout oriented programming. With Unicode this situation has changed: One character is no longer one byte, so that additional specifications have to be added to define the unit of measure for implicit or explicit references to (the length of) characters.
Character-like data in ABAP are always represented with the UTF-16 - standard (also used in Java or other development tools like Microsoft's Visual Basic); but this format is not related to the encoding of the underlying database. 
A Unicode-enabled ABAP program (UP) is a program in which all Unicode checks are effective. Such a program returns the same results in a non-Unicode system (NUS) as in a Unicode system (US). In order to perform the relevant syntax checks, you must activate the Unicode flag in the screens of the program and class attributes.
In a US, you can only execute programs for which the Unicode flag is set. In future, the Unicode flag must be set for all SAP programs to enable them to run on a US. If the Unicode flag is set for a program, the syntax is checked and the program executed according to the rules described in this document, regardless of whether the system is a US or a NUS. From now on, the Unicode flag must be set for all new programs and classes that are created.
If the Unicode flag is not set, a program can only be executed in an NUS. The syntactical and semantic changes described below do not apply to such programs. However, you can use all language extensions that have been introduced in the process of the conversion to Unicode.
As a result of the modifications and restrictions associated with the Unicode flag, programs are executed in both Unicode and non-Unicode systems with the same semantics to a large degree. In rare cases, however, differences may occur. Programs that are designed to run on both systems therefore need to be tested on both platforms.
Other Changes 
1.     Bit Statements
2.     Adding Field Sequences
3.     Loops with VARY and VARYING
4.     Creating Subroutines
5.     Saving Programs
6.     Assigning Types for GET/SET PARAMETER
7.     Unreachable Statements
8.     Function Modules with Incorrect Parameter Names
1. Bit Statements
Previously, the system checked for the bit statements SET BIT i OF f [TO g] and GET BIT i OF f [INTO g]whether the field f is character-type; X fields, X strings, and flat structures are usually regarded as character-type. For Unicode programs this is no longer useful, because the types X and XSTRING no longer count as character-type and the bit by bit access to character-type fields or structures is no longer platform-independent. Therefore, with these operations in Unicode programs, the field f must be type X or XSTRING.
For the bit mask operations f O x, f Z x, and f M x you could previously use all number-type and hence all character-type types for the left operand f. In Unicode programs, the f operand must now be type X or XSTRING.
2. Adding Field Sequences
When adding field sequences, restrictions apply to the following statements in Unicode:
ADD n1 THEN n2 UNTIL nz [ ACCORDING TO sel ] GIVING m ...
ADD n1 THEN n2 UNTIL nz TO m [ RANGE str ].
1.     The operands n1, n2, and nz must be type-compatible with one another.
2.     The distance between nz and n1 must be an integral multiple of the distance between n2 and n1.
3.     A syntax or runtime error occurs if the fields n1, n2, and nz are not in a structure. This structure must be recognizable statically or its valid area must be marked explicitly using the RANGE addition.
4.     At runtime, the system ensures that the RANGE area is not left.
ADD n1 FROM i1 GIVING m [ RANGE str ].
1.     Field n1 must be within the structure. The structure must be explicitly defined using the RANGE addition if it is not recognizable statically.
2.     For this variant, the system also checks at runtime whether n1 and the addressed values are within the structure.
3. Loops
Loops with the VARY or VARYING addition are also problematic in Unicode, since a type-a access to memory contents cannot be ensured and memory can be overwritten inadvertently.
DO ... VARYING f FROM f1 NEXT f2.
For this statement, the fields f, f1, and f2 must be type-compatible with each other. To prevent memory contents being overwritten, a RANGE for valid accesses is introduced implicitly or explicitly for the following statements:
DO ... TIMES VARYING f FROM f1 NEXT f2 [ RANGE f3 ].
WHILE ... VARY f FROM f1 NEXT f2       [ RANGE f3 ].
A syntax or runtime error is caused if f1 or f2 are not included in f3. If the RANGE addition is missing, it is defined implicitly from FROM f1 NEXT f2 as follows:
1.     If both f1 and f2 are statically recognizable components of the same structure, the valid RANGE area is defined from the smallest structure that comprises f1 and f2.
2.     A syntax error is triggered if it is recognizable statically that f1 and f2 are not part of the same structure.
3.     A valid area must be defined explicitly using the RANGE addition if the connection between f1 and f2 is not recognizable statically.
If you specify a deep structure as the RANGE addition, the system checks for every loop pass that there are no field references, object references, tables, or strings in the area read.
4. Creating Subroutines
When automatically generating subroutines using the statement GENERATE SUBROUTINE POOL itab NAME name, the generated program inherits the content of the Unicode flag of the generating program.
5. Saving Programs
When automatically generating programs using the statement INSERT REPORT prog FROM itab, default values are set for the TRDIR entry as before. Amongst other things, this statement has the new addition UNICODE ENABLING uc, with which the Unicode flag of the inserted report receives the value of uc. If this addition is missing, the following applies:
1.     A Unicode program creates a Unicode program.
2.     A non-Unicode program in turn creates a non-Unicode program.
3.     A non-Unicode program becomes a Unicode program if it is overwritten by a Unicode program.
4.     A Unicode program remains a Unicode program if it is overwritten by a non-Unicode program.
6. Assigning Types for GET/SET PARAMETER
For the statements GET PARAMETER ID pid FIELD f and GET PARAMETER ID pid FIELD f, f must be character-type. You can use the EXPORT and IMPORT statements for storing non-character-type fields and structures.
7. Unreachable Statements
In Unicode programs, unreachable statements cause a syntax error. In non-Unicode programs, there was previously only a syntax warning.
8. Function Modules with Incorrect Parameter Names
In Unicode programs, calling a function module, whose parameter names are specified statically as a literal or constant, causes an exception that can be handled if an incorrect parameter name was specified. This only applies to function modules that are not called via Remote Function Call. In non-Unicode programs, an incorrect name was previously ignored.

Similar Messages

  • Interview questions on upgrades from 4.7 to ECC

    Hi,
    Can any one please post some potential areas/questions that will be asked for upgrade projects from 4.7 to ECC6.0
    Points will be awarded.
    Thanks

    Hi Frank,
      this is good question,  why because sap upgrades from 4.6b to ecc 6.0 is very risky.
      take one example , in 4.5b , me21n application having 620 screen where as in ecc 6.0 having 9000 screen . that time we will take care of it.
       check the obsolete function modules ,  4.5b , having ws_upload, ws_download.... use cl_gui_frontend_services , under these having differnt type of methods.
      once you change the code in ecc , go to tranx : SLIN check the error where it is exact.

  • Error during Upgrade from 4.6c to ECC 6.0

    Hi All,
      We are facing an error when upgrading from 4.6c to ECC 6.0. We are facing this error on the table COEP - runtime object inconsistancy. What we found is there is ERP upgrade has created new extra fields in the table. In log file the error is specified as : Duplicate Field name, But we not able to find the duplicate field name in the table.  Please kindly help as early as possible. The upgrade process is stuck.
    Regards
    Anil Kumar K

    Hi Anil,
    Is this issue fixed? Can i know how you fixed it?
    replied to your message Re: How to adopt the index changes during upgrade.
    Thanks,
    Somar

  • Unicode error while upgrading from 4.6 to ECC 6.0

    Dear All,
    I am getting unicode errror while upgrading from 4.6 to ECC 6.0, when iam trying to open downloaded file in excel.
    In debugging, error occurs while executing statment "CALL METHOD OF obj_ex_sheet " in the code given below:
    FORM open_downloaded_file_in_excel            *
    FORM open_downloaded_file_in_excel.
      DATA:
        lv_ole_books       TYPE ole2_object,
        lv_ole_sheets      TYPE ole2_object,
        lv_subrc           LIKE sy-subrc,
        lv_title(70)       TYPE c,
        lv_text1(70)       TYPE c,
        lv_text2(70)       TYPE c.
    start excel
      CREATE OBJECT obj_ex_sheet      'EXCEL.SHEET'.
      IF sy-subrc NE 0.
        lv_subrc = sy-subrc.
        FREE OBJECT obj_ex_sheet.
        PERFORM error_handling_ms_excel USING lv_subrc.
      ENDIF.
      CALL METHOD OF obj_ex_sheet     'Application' = obj_ex_app.
      IF sy-subrc NE 0.
        lv_subrc = sy-subrc.
        FREE OBJECT obj_ex_app.
        FREE OBJECT obj_ex_sheet.
        PERFORM error_handling_ms_excel USING lv_subrc.
      ENDIF.
      SET PROPERTY OF obj_ex_app 'Visible' = 1.
    open data file: main file
      CALL METHOD OF obj_ex_app        'Workbooks'  = lv_ole_books.
      CALL METHOD OF lv_ole_books      'Open'       = obj_ex_wbook
        EXPORTING #1  = gv_filename
                  #2  = 2
                  #3  = 0
                  #4  = 1
                  #5  = 0
                  #6  = 0
                  #7  = 1.
      IF sy-subrc NE 0.
        lv_subrc = sy-subrc.
        FREE OBJECT obj_ex_wbook.
        FREE OBJECT obj_ex_app.
        FREE OBJECT obj_ex_sheet.
        PERFORM error_handling_ms_excel USING lv_subrc.
      ENDIF.
      FREE OBJECT lv_ole_books.
      CALL METHOD OF obj_ex_wbook      'Worksheets' = lv_ole_sheets.
      CALL METHOD OF lv_ole_sheets     'Item'       = obj_ex_wsheet
        EXPORTING #1 = 1.
      FREE OBJECT lv_ole_sheets.
      GET PROPERTY OF obj_ex_wsheet    'UsedRange'  = obj_ex_usedrange.
      CALL METHOD  OF obj_ex_usedrange 'AutoFormat'
        EXPORTING #1 = 18.
      SET PROPERTY OF obj_ex_wsheet    'Name'       = sy-tcode.
      FREE OBJECT obj_ex_usedrange.
      PERFORM free_ole_objects.
      CALL FUNCTION 'FLUSH'
           EXCEPTIONS
                OTHERS = 0.
    ENDFORM.                              
    regards,
    Divya

    hi,
    In the OPEN DATASET STATEMENT ADD THE ENCODING ADDITION IN TEXT MODE.
    Regards,
    Balakumar.G
    Reward Points if helpful.

  • Top-Down Distribution - tcode KE28 (release upgrade from 4.6 to ECC 6.0)

    All,
    we are performing a release upgrade from 4.6 to ECC 6.0 and we have a problem with the tcode KE28.
    The variant already set up in the system don't match with the selection fields present in the screen, and the following message is shown:
    Message no. KG346
    The variant does not adhere to the current Customizing setup
    We have saved the variant again, and no problem are present, but the error message refers also to Customizing setup.
    Is there a section in the Customizing where it is possible set up the field to show in the initial screen or the new fields (All Valuation Views, Legal Valuation View and Profit Center Valuation View) are due to the release upgrade?
    If yes, do you know the transaction/path?
    Thanks in advance for your collaboration.
    Regards,
    Jody Mancini.

    Hi Satish,
    Now i am sending some URL for Functional upgrade
    May be those are all useful toyou
    https://www.sdn.sap.com/irj/scn/wiki?path=/display/erp6/transactionsChangedinECC6.0
    http://solutionbrowser.erp.sap.fmpmedia.com/Default.aspx
    https://www.sdn.sap.com/irj/scn/wiki?path=/display/erp6/
    Regards
    Surya

  • Performance issue after Upgrade from 4.7 to ECC 6.0 with a select query

    Hi All,
    There is a Performance issue after Upgrade from 4.7 to ECC 6.0 with a select query in a report painter.
    This query is working fine when executed in 4.7 system where as it is running for more time in ECC6.0.
    Select query is on the table COSP.
    SELECT (FIELD_LIST)
            INTO CORRESPONDING FIELDS OF TABLE I_COSP PACKAGE SIZE 1000
            FROM  COSP CLIENT SPECIFIED
            WHERE GJAHR IN SELR_GJAHR
              AND KSTAR IN SELR_KSTAR
              AND LEDNR EQ '00'
              AND OBJNR IN SELR_OBJNR
              AND PERBL IN SELR_PERBL
              AND VERSN IN SELR_VERSN
              AND WRTTP IN SELR_WRTTP
              AND MANDT IN MANDTTAB
            GROUP BY (GROUP_LIST).
       LOOP AT I_COSP      .
         COSP                           = I_COSP      .
         PERFORM PCOSP       USING I_COSP-_COUNTER.
         CLEAR: $RWTAB, COSP                          .
         CLEAR CCR1S                         .
       ENDLOOP.
    ENDSELECT.
    I have checked with the table indexes, they were same as in 4.7 system.
    What can be the reson for the difference in execution time. How can this be reduced without adjusting the select query.
    Thanks in advance for the responses.
    Regards,
    Dedeepya.

    Hi,
    ohhhhh....... lots of problems in select query......this is not the way you should write it.
    Some generic comments:
    1. never use SELECT
                       endselect.
       SELECT
      into table
       for all entries in table
      where.
       use perform statment after this selection.
    2. Do not use into corresponding fields. use exact structure type.
    3. use proper sequence of fields in the where condition so that it helps table go according to indexes.
        e.g in your case
              sequence should be
    LEDNR
    OBJNR
    GJAHR
    WRTTP
    VERSN
    KSTAR
    HRKFT
    VRGNG
    VBUND
    PARGB
    BEKNZ
    TWAER
    PERBL
    sequence should be same as defined in table.
    Always keep select query as simple as possible and perform all other calculations etc. afterwords.
    I hope it helps.
    Regards,
    Pranaya

  • What are the key points to beconsider while upgrading from 4.7 to ECC 6.0

    hai
    What are the key points to beconsider while upgrading from 4.7 to ECC 6.0
    please provide sufficient material
    points will be rewarded
    regards
    v.sridhar

    Hi Sridhar,
    Please visit the following links:
    http://service.sap.com/erp
    http://solutionbrowser.erp.sap.fmpmedia.com/ (Functional perspective)
    http://service.sap.com/instguides --> mySAP Business Suite Applications --> mySAP ERP --> mySAP ERP 2005 --> Upgrade
    http://help.sap.com/printdocu/core/Print46c/en/data/pdf/LOVC/LOVC.pdf
    For Functionality Differences pls refer to the below site -
    http://solutionbrowser.erp.sap.fmpmedia.com/
    After opening the site, please select the Source Release Version which is 4.6 b Then Select the Target Release Version which is "mySAP ERP 2005" or ECC 6.0
    Select the Solution Area like Financials, Human Capital Management, Sales....
    Select module like MM, PP, SD, and QM.....
    Click on Search
    then it displays the Release Version and the Delta Functionality. Which can be downloaded to a word document if required.
    And also check the release notes of ECC 6.0 in service.sap.com.
    When you are upgrading from 4.6C to ECC6
    Nothing major, follow the same process you'd follow if you were updating PI service packs in R/3 or enhancing data sources. Empty queues in RSA7 and lbwq. Also empty setup tables through lbwg as the upgrade doesn't like it if these tables contain data. This is all on the R/3 side (although you empty RSA7 by running each delta TWICE in BW).
    To transfer queues from lbwq to rsa7, execute jobs through LO cockpit (lbwe).
    Some of your data sources could also be using sm13 instead of lbwq, so do check it out as well.
    For installing ECC 6.0 you required a solution manager key. With out solution manager key you cannot install ECC6.0.
    For ECC 6.0 is called net weaver component here you have ABAP+JAVA stack.
    ECC6.0 supports UNCODE.
    For installing 4.6 you don't require solution manager key. It only having ABAP stack.
    4.6C supports NONUNICODE.
    Major difference is ECC6 is netwear product having WASJAVA+ABAP
    secondly support unicode apart from this we have other diff. you can get form master guide from service.sap.com/instguides.
    Please go through the link that is shown here and if there is any doubts then feel free to ask.
    Major difference is ECC6 is net weaver  product having WASJAVA+ABAP
    secondly support Unicode apart from this we have other diff. you can get from master guide from service.sap.com/instguides
    For installing ECC 6.0 you required a solution manager key. With out solution manager key you cannot install ECC6.0.
    For ECC 6.0 is called net weaver component here you have ABAP+JAVA stack.
    ECC6.0 supports UNCODE.
    For installing 4.6 you don't required solution manager key. It only having ABAP stack.
    4.6C supports NONUNICODE.
    Please also Refer sdn thread and make a small search where u can find lot of information Reg this
    olution Browser would give the differences (Features):
    http://solutionbrowser.erp.sap.fmpmedia.com/ Give source and target versions.
    Release Info:
    ECC 6.0:
    http://help.sap.com/saphelp_erp2005/helpdata/en/43/68805bb88f297ee10000000a422035/frameset.htm
    Refer below and search for posts on this topic on sdn
    There are so many differences between the version in different objects
    I
    These are the some of the settings that are differed in the two versions and in that two objects
    Please visit the following links:
    http://service.sap.com/erp
    http://solutionbrowser.erp.sap.fmpmedia.com/ (Functional prespective)
    http://service.sap.com/instguides --> mySAP Business Suite Applications --> mySAP ERP --> mySAP ERP 2005 --> Upgrade
    http://help.sap.com/printdocu/core/Print46c/en/data/pdf/LOVC/LOVC.pdf
    For Functionality Differences pls refer to the below site -
    http://solutionbrowser.erp.sap.fmpmedia.com/
    Upgrade from 4.6c to 6.0 ECC
    upgrade from 4.7 to ecc 6.0
    Please Do Reward If Really Helpful,
    Thanks and Regards,
    Sateesh.Kandula

  • Issues during technical upgrade from 4.6c to ecc 6.0

    Hi
    We are doing a technical upgrade from 4.6C to ECC 6.0. Some transactions in QM module when tested in ECC 6.0 test client give a abap termination message (or dump) and certain transactions like qs42,46, qa18, qs34 etc do not get executed (error = no entry foound for......) and similarly in PP-PI module transactions like C203 have similar problems, even though master data does exist. What should I look for?  Can somebody pl. give details on configuration checks and the OSS notes from a functional point of view for a technical upgrade?
    For certain transactions I get the error message - "Central system of distribution SM-P06CLNT430_TRUSTED is unreachable RFC destination SM_P06CLNT430_Trusted does not exist" - what does this mean?
    thanks
    BE

    Hi,
    1. Have you done successfull installation from 4.6C to ECC 6.0 at the time of PrePare ans SAPUP?
    2. Check SP' for QM and PP-PI modules from http://service.sap.com/sp-stacks.
    3. Configure RFC connections correctly, SM_<SID>CLNT<No>_Trusted automatically created, not manually.
    http://service.sap.com/notes --> search for RFC trusted connections for Ecc 6.0
    http://service.sap.com/upgrade.
    Regards,
    Srini Nookala

  • Upgrade from 4.6c to ecc 6.0

    Hi,
    We are doing a technical upgrade from 4.6c to ecc 6.0 without activating New GL. As a functional consultant, what should i look for? I know that we need to test the business processes and check Z programs but anything specific, plzz let me know.
    What changes should be made in Asset Accounting?
    Regards
    Satya

    Thanks for the reply.
    What are the  changes made in Asset accounting after upgrading?
    I heard of RBE tool...how is it used for FI?? (u check for the mostly used transactions or what??)
    Anyone, plzz answer..waiting for ur replies
    Regards
    Satya

  • Upgrade from 4.7 to ecc 6.0

    hi
    it would be great help if you tell me about the upgrade from 4.7 to ecc 6.0 am an sd functional consutlant so wat would be my role in this upgrade and are the transaction codes and menu path same or have some changes in it and could please tell me some sd transaction code and some interview related question wat they ask while taking an upgrade interview for a sd consultant
    thanks in advance
    priti

    Dear Priti,
    Visit the following link:
    http://solutionbrowser.erp.sap.fmpmedia.com/  .......give source and target versions to find the difference.
    Major difference is ECC6 is netwear product having WASJAVA+ABAP secondly support unicode apart from this we have other diff. you can get fom master guide from service.sap.com/instguides.
    For installing ECC 6.0 you required a solution manager key.With out solutionmanager key you cannot install ECC6.0.
    For ECC 6.0 is called netweaver component here you have ABAP+JAVA stack.
    ECC6.0 supports UNCODE.
    For installing 4.6 you don't required solution manager key.It only having ABAP stack. 4.6C supports NONUNICODE.
    http://help.sap.com/saphelp_erp2005/helpdata/en/43/4d2091de9657bfe10000000a155369/content.htm
    Hope this will help.
    Regards,
    Naveen.

  • Upgrade from 4.0B to ECC 6.0

    Hi
    I have few questions related to upgradation from 4.0B to ECC 6.0 (wrt HR)
    To wat extent it is possible, if yes then how simple or difficult it is ?
    Time Factor (Duration)?  ?(assuming the size of the company close to 1000)
    Do we have any set of standard procedures and guidelines that are to be followed ?
    any helpfull documents to understand the process?
    Thanks in advance..
    Regards
    Rao

    Rao,
    My new project is upgrade project from 4.0B to ECC 6.0 in MM/IM/WM area,
    I have to give an estimate of duration to complete this project.
    Have you started your project. how is it going? how long the project? and any other useful documents please pass on "[email protected]"

  • After upgrading from 4.6C to ECC 6.0 templates not working in smartform

    Hello,
    After upgrading from 4.6C to ECC 6.0 templates not working properly in smartform, although value is flowing to the point the template is getting called and inside the template there are text elements where placeholders are kept to display the value, when the print is taken there are no values being displayed by the text elements.
    Please note - Text elements doesnot have any conditions present in the condition tabstrip.
    Thanks,
    Abhishek

    Hi,
    After the upgrade, you will have to do the security upgrade.
    Please follow these steps.
    1. Go To SU25
    2. Run step 2A to 2D.
    3. In step 2C, you shall get the list of all the affected roles.
    Click on first role. It will take you to authorizations of that role. Click on the "New" tab there to find the new objects added to the role after the upgrade.
    Note: You can open the same role in the unupgraded system to check.
    4. Provide the access to the required authorization objects.
    5. Disable the unwanted authorization objects.
    6. Generate the profile.
    7. Follow the same steps for all the affected roles listed.
    Please note that you will have a list of new objects added.You need to maintain them inorder to avoid any access issues.
    8. After step 2C, complete 2D.
    Regards,
    Imran

  • Upgrade from 4.7 to ECC 6.0 and MICR no longer printing

    Hello,
    We are in the process of upgrading from 4.7 to ECC 6.0.  Our checks in FI and HR which have MICR fonts/lines are no longer printing the MICR lines.  Any ideas on what to check?

    Hi Kenneth,
    If you have any documentation for Upgrading from 4.7 to ECC 6.0 can you pls send it to me ?
    Thanks
    Christine

  • Schema error after upgrade from 4.6C to ECC 5.0

    Hi all,
    We have recently upgraded from 4.6C to ECC 5.0. We are having problem in payroll run. When I did a syntax check in schema, I got "UDPM" rule doesn't exist. I checked, this rule is present in 4.6C. This is the standard rule. If I am right, it should have come with upgrade right?
    or SAP has changed this? From where Can I get the info about this?
    Also similar error I got in Function 'USTAX' parameter 3 is not allowed. If I remove that parameter, I don't know what is the implication of that.
    I checked for SAP notes. I did not find anything.
    Please let me know if any of you have come with such situation.
    Thanks in advance.
    Sarika.

    Hi Sarika,
    We are also in a similar transition i.e. 4.6C to mysap Ecc5.0 . But we are on Canadian Payroll.
    I had search OSS and got a PDF document regarding " Upgrading to SAP R/3 Enterprize - A User Guide to Canadian mysap HR Customers" . U may be can find a similar one for US payroll. I can give u mine, but it wont be of any use as it is for Canadian Payroll.
    In Canadian mysap Upgrade , the function P0224 has been replaced by function KXDTM . Although P0024 is still in used in Schema K00T for conversion purposes.
    Regards,
    Jay Gandhi

  • Layouts disappear after upgrade from 4.6c to ECC 6.0

    HI friends ,
    In the upgrade from 4.6c to ECC 6.0 , the layouts in the SAP QUERIES in the new system are either lost or showing lesser fields than original system .How do get the exact layouts as in 4.6c?
    Please help...
    Many thnx ,
    Hemanth .

    Try using SQVI transaction .
    Please reward if useful.

  • Upgrade from 4.6B to ECC 6.0

    We are involved at upgrading from 4.6b to ECC 6.0. we have to upgrade to FSCM also and use the TPM_MIGRATION.
    Has anybody experience over this tool?.
    Any help will be apreciated.
    Thanks,
    Alfonso

    Dear ,
    You may have a look in SAP Note 830077 (FAQ tpm_migration ) for more details.
    Regards,
    Lucio Rodrigues

Maybe you are looking for

  • Printing indicator in mat. doc

    Dear all, When viewing a material document in MB03, it is found that the print indicator is selected, but none of the printing options: Individual Slip/Indiv.Slip w.Inspect.Text/Collective Slip is selected. I just wonder how user could do so, as it i

  • Graphics corrupted / garbled display on Core Duo MacBook Pro (ATI)

    My first-generation (Core Duo) MacBook Pro (with ATI chipset) is having video problems. When this happens, the graphics become corrupted / display becomes garbled and the computer freezes shortly afterwards making it basically unusable. You can just

  • 403   Forbidden  You are not authorized to view the requested resource.

    Hello all I am getting this error when I perform a full CPA CACHE refresh. I have already check those steps : •  HTTP 403 during cache refresh of the adapter framework - Refer SAP Note -751856 • Because of Inactive Services in ICF –Go to SICF transac

  • Syncing iTunes with my iPad2

    I have my music library in iTunes on my PC. Included are CD's that I have downloaded. When I sync my iPad2 with the iTunes on the PC, I do not get the downloaded CD's onto my iPad, only the iTunes purchases. How do I get my CD's in the iPad as well?

  • Multiple Agreement for Single Project

    Hi All, In our Implementation client generally gets multiple agreements for a single project. How to specify the Agreement Reference when we are creating an Event for billing? By the way have set up the funding option at the Project Level. Thanks in