Vision acquisition timeout error

 Good day! I do not know what is wrong but my VI suddenly stops with a timeout error. I cannot find the wrong thing. Your help would be much appreciated. 
Attachments:
QRCodeReader24vi.vi ‏719 KB

Good day sir! Yes, I only need one image for all of my Vision Assistant's analysis. All of my Vision Assistant has an Extract Single Color Plane VI. After executing the first Vision Assistant, the image produced by the lone Vision Acquisition I left is already extracted to its Single Color Plane. This brings error to my remaining Vision Assistant VI for they cannot extract the image to its single color plane anymore because the image is already converted. Why does this happen? I assured that the Vision Assistants are connected in parallel to the Vision Acquisition, meaning every Vision Assistant is connected to the output of the Vision Acquisition. 
Thank you for the tip on using Flat Sequence Structure in my VI. It works and doesn't display any timeout error. 
 I have an another issue. I put a Play Sound File VI. I am sure that I have put the right path but it displays Error 4805 occurred at Play Sound File.vi that it cannot find the sound file. I tried to do this in a new VI without any while loop or case structure and it works. 
Also, can you give me a tip what to use to display a certain image file if for example I typed "a", and another certain image file if I typed "b". 
So far, the most important part of my system, the image acquisition is resolved. I owe this to you. Thank you, sir!
I attached a screenshot of the Play Sound File error.
Attachments:
PlaySoundFileError.JPG ‏116 KB

Similar Messages

  • Vision Acquisition Express VI error

    Hello
    I am new in labview and I am using the Vision Acquisition Express VI in a while loop. When I run the code, I get an error message " NI-IMAQdx: (Hex 0xBFF69004) Invalid camera session".
    Please help me
    Attachments:
    screenshot.png ‏7 KB
    visionacquisition.vi ‏105 KB

    Which iteration? If it fails from the very first its likely that the express VI is not configured correctly. If it fails on subsequent iterations there might be a problem using the express VI in a loop (never use express VIs inside loops).
    Mike...
    Certified Professional Instructor
    Certified LabVIEW Architect
    LabVIEW Champion
    "... after all, He's not a tame lion..."
    Be thinking ahead and mark your dance card for NI Week 2015 now: TS 6139 - Object Oriented First Steps

  • Vision acquisition error 2147023898

    I'm working with a usb3.0 camera to and labview vision acquisition.
    I just want to have a simple live image.
    in the configuration the image is shown and everything works fine, but when a finish this and run the vi i get an error.
    Error -2147023898 and is undefined in labview.
    Could someone help me with this problem
    in the attacement 2 images show the error and the working configuration
    Attachments:
    ids acquisition.PNG ‏42 KB

    Dont use express vi. Use imaqdx open outside the while loop. Use a snap inside the while loop and use a close outside the loop.

  • Timeout error (code 6101) for acquisition from MODBUS instrument

    I am experiencing a problem which other users have reported, but for which little useful information has been posted:
    I am trying to acquire data from an instrument using MODBUS RTU protocol.  The code works as desired for a while, but will intermittently stop executing and give a timeout error, code 6101.  This code seems to be associated with the MB Serial Master Query sub VI.  In the past, I was getting this error as a result of RF noise corrupting the signal in the USB connection to the instrument.  Removing the USB cable from the noisy environment eliminated the problem.  I am now having the problem with an RS 485 line in the noisy environment, which should be very stable in noisy environemnts. 
    My question:  is there a coding trick i can use to reconnect in the event that a corrupt signal occurrs (or some other problem which results in the intermittent appearence of the error 6101)?   I've increased the timeout value on the MB Serial Master Query sub vi, but this hasn't helped.  Any input is appreciated.  In case it's useful, I've posted a simple version of code which generates the problem. 
    Thanks,
    Paul   
    Attachments:
    Floating point 1.12.vi ‏24 KB
    timeout error1.JPG ‏31 KB

    Thanks for your input, Ravens Fan.  I am indeed getting a popup error message with the timeout.  I agree that putting the MODBUS read in its own loop would solve the problem.  However, I'm struggling with trying to figure out how to actually do this.  Should I put the read in a case structure or a while loop?  How do I go about looping back to re-execute the read statement?  I think so called "state machine architecture" seems to be where I should be going. Some example code would be greatly appreciated. 
    paul  

  • Frame timeout error using Configure Trigger3.vi

    Hi all,
    I'm triggering the frame capture of an .avi with an RTSI connection.  However, I keep getting a frame timeout error when I use the IMAQ Configure Trigger3.vi.  I don't get any timeout errors when I just use the IMAQ Generate Pulse3.vi but I am trying to sync the frame capture to an optical switch.  If I just use IMAQ Generate Pulse3.vi, I get a .avi but the frames are completely out of sync with the switch, but if I use both IMAQ Generate Pulse3.vi  and Configure Trigger3.vi I get nicely separated images but it takes an age and ends up in a timeout error.
    I want to capture e.g. 500 frames, over the course of 2 s - so I've set my frame timeout to be 2000.   At my current acquisition rate (31680 Hz per line (1024 pixels)) 500 frames corresponds to a total of 1.578 s (images are 100 pxls in height).  This is much less than the total scanning time.  Where am I going wrong?
    Thanks in advance for your help.
    Miika
    Attachments:
    screen.png ‏32 KB

    Hey Miika
    What are the hardware you are using. These vi's only work with specific hardware and this may be why they are not functioning correctly. For example the Configure trigger3 vi only works with the following PCIe-1427, PCIe-1429, PCe-1430, PCIe-1433.
    Matthew Trott
    Applications Engineer
    National Instruments UK
    www.ni.com/ask

  • Open cam VI in Main.exe and Vision Acquisition License

    Hi,
    I've an application which controls some devices...I've two questions:
    1. I'm building an exe of my main VI. When I run it as exe on other PCs, it doesn't open the subVI (cam_pos_test.vi) (on my PC is everything running ok). The cam subVI is added in the always included VIs, when I build the application. Part of the main level VI looks like this (control/producer loop):
    in the red circle is the subVI which opens the Ref to the cam_subVI. It looks like this:
    I think: I make some error in the defining the path of the subVI (cam_pos_test.vi). Do you have some idea, what could be wrong? Why the cam_pos_test does not pop-up as it should on the other machines? :-) I've tested the cam_pos_test.vi as exe is running on other PCs.
    2. I've Vision Acquisition License on my PC. Do I need Vision Acquisition License also for the PC where the executable is running (to use a cam)?
    Thanks!
    Angel

    Hi,
    I've LabVIEW 2010 Prof. + Vision Acquisition License on my PC (where I write the code). To check: is the problem in the source code or in the executable, I've used an evaluation version of LV2010 on another PC ... as a VI it runs without problems on the lab PC, but as an executable it runs but doesn't open the cam window :-( (everything else is ok)
    The code of the cam.VI is attached. I've used only IMAQdx VIs to obtain an image from the cam...
    Thank you for your time,
    Angel
    Attachments:
    cam_pos_test.vi ‏65 KB

  • Saving Images Using Vision Acquisition Express

    I'm trying to save an Image as a jpg using Vision Acquisition Express. My code looks like this. I am able to view the images and scroll through them afterwards, but when I add the file saving portion, I get an error that says "Error 1074395995 occured at IMAQ WriteBMPFile File not found."
    How should I go about Fixing this? 
    Also, when i was running this before, I was getting a memory error and I couldn't figure out how to clear the memory. I was only able to fix this by scraping my previous script and starting over. I haven't gotten this error so far.
    Attachments:
    TakingImages.vi ‏156 KB

    Hi,
    The error you are getting indicates that the file path is invalid.  I just set the file path to my desktop and I could save the files.  I would double check to make sure the path you specified is valid for the computer you are running it on.
    As far as the memory error, it is really hard to say what the cause is.  If you aren't getting it anymore then I wouldn't be to concerned.
     Regards,
    Greg H.
    Applications Engineer
    National Instruments

  • MS2026 -anvna Wait for Acquisition Complete -ERROR

    Hi Everyone,
    I wrote a labview program (LV 7.1) with instrument MS2026A VNA (Anritsu) and it was working fine.
    However the original equipmet stopped working last week and we have received a loaner (until our is fixed), same model, but does not work with my labview program.  I even try running this equipment with the sample program provided by NI:  "anvna Acquire Trace Example" and it gives me an error -please refer to attached pictures.
    The error is in the "anvna Wait for Acquisition Complete.vi."  I think it has to do with timeout (256).  I have added delays all over but nothing helps.  I used to have this same problem on the first instrument but it disappear "mysteriously."
    Could somebody point me to way to fix this issue?   Thanks very much,
    Frank
    Attachments:
    anvna Wait for Acquisition Complete -ERROR.gif ‏10 KB
    anvna Wait for Acquisition Complete.gif ‏26 KB

    Hi Fvalenzu,
    I have a few questions about your application. 
    Is the replacement instrument the same revision of the instrument you sent to get repaired? 
    Is the device at the same address? 
    Are you able to successfully communicate with the instrument in max using GPIB commands?
    You might want to verify the program is calling the instrument by the correct alias or address and you are calling the device correctly.  Also, I would check and see if there is a newer version of the IVI driver for your instrument. IVI drivers can be found at the link below. 
    ni.com/idnet
    Regards
    Message Edited by Andy L on 08-17-2007 06:25 PM
    Andy L.
    Applications Engineer
    National Instruments

  • IMAQdx Timeout Error 0xBFF6901B

    Using IMAQdx with GigE camera, I get a
    Timeout error 0xBFF6901B.
    What is this error?

    This is an old thread, but I had the same problem with a different solution.I had one working Basler Camera, and on non working Basler camera.   Turns out I needed to disable test packets on the non working camera by this procedure:http://digital.ni.com/public.nsf/allkb/8D9A975B04F66B728625768900805A21 which states:The test packet timeout error can also be handled by configuring the Test Packets Enabled attribute for the camera to be disabled in Measurement & Automation Explorer (MAX). Follow these steps to set this attribute:
    Open MAX.Click on the Basler GigE camera under Devices and Interfaces»NI-IMAQdx Devices.Choose the Camera Attributes tab.Click on View Options listed right above the camera attributes, and then choose to View All. This allows all camera attributes to be displayed.Click on Expand All to list all the attributes.Select the Test Packet Enabled attribute and set it to be disabled.7.      SAVE THE CONFIGURATION That will generate a new error of 0xBFF60493 which will be fixed by this accepted solution:http://forums.ni.com/ni/board/message?board.id=200&message.id=26623&query.id=806694#M26623  which states:In MAX (Tools->NI Vision->Remote Image Options...) and turn off the option to "Display images on remote monitor."  Message Edited by screamingmouse on 05-14-2010 06:52 PM

  • Vision usb camera error

    Hi,
    I am using LabVIEW version 9 and Vision Acquisition software together with a USB 2.0 digital camera. My error is that when i run my VI, the Vision Acquisition software can't find the camera but it can find it only if the VI is not running. (Attached below is the error that I get). How do I solve this issue?
    Solved!
    Go to Solution.
    Attachments:
    Lens VI.zip ‏472 KB

    Hello LHX, 
    Are you still encountering the same error?  
    When you say that it "can find it only if the VI is not running", can you elaborate on this statement? Are you able to see your USB camera inside of Measurement & Automation Explorer (MAX) and are you able to successfully grab images from there? That will be the first thing to check. Because if it cannot grab images inside of MAX, then you will not be able to in your VI. 
    You also may want to verify that your Vision Acquisition Software (VAS) license is indeed activated for you computer. You can check this by going to the NI License Manager program. 
    Huntington W
    National Instruments
    Applications Engineer
    ***Don't forget to give Kudos and Accepted as Solution where it is deserved***

  • TimeOut error while running a report on the report server

    Hi,
    One of my report is taking 30 minutes to generate the output. It works fine when I run it locally, but when I run it on report server I encounter the following error message. Its a timeout error. Any solution other than tuning the query, please.
    500 Internal Server Error
    org.omg.CORBA.OBJECT_NOT_EXIST: minor code: 0 completed: No
         at java.lang.Class.newInstance0(Native Method)
         at java.lang.Class.newInstance(Class.java:237)
         at com.inprise.vbroker.orb.SE.read(SE.java:28)
         at com.inprise.vbroker.orb.DelegateImpl.handleReply(DelegateImpl.java:711)
         at com.inprise.vbroker.orb.DelegateImpl.invoke(DelegateImpl.java:606)
         at org.omg.CORBA.portable.ObjectImpl._invoke(ObjectImpl.java:459)
         at oracle.reports.server._ConnectionStub.getMainFile(_ConnectionStub.java:1283)
         at oracle.reports.client.ReportRunner.getMainFile(ReportRunner.java:488)
         at oracle.reports.rwclient.RWReportRunner.getMainFile(RWReportRunner.java:121)
         at oracle.reports.rwclient.RWReportRunner.getMainFile(RWReportRunner.java:95)
         at oracle.reports.rwclient.RWClient.runReport(RWClient.java:1322)
         at oracle.reports.rwclient.RWClient.processRequest(RWClient.java:1139)
         at oracle.reports.rwclient.RWClient.doPost(RWClient.java:328)
         at javax.servlet.http.HttpServlet.service(HttpServlet.java:283)
         at javax.servlet.http.HttpServlet.service(HttpServlet.java:336)
         at com.evermind[Oracle9iAS (9.0.2.0.0) Containers for J2EE].server.http.ResourceFilterChain.doFilter(ResourceFilterChain.java:59)
         at oracle.security.jazn.oc4j.JAZNFilter.doFilter(JAZNFilter.java:283)
         at com.evermind[Oracle9iAS (9.0.2.0.0) Containers for J2EE].server.http.ServletRequestDispatcher.invoke(ServletRequestDispatcher.java:523)
         at com.evermind[Oracle9iAS (9.0.2.0.0) Containers for J2EE].server.http.ServletRequestDispatcher.forwardInternal(ServletRequestDispatcher.java:269)
         at com.evermind[Oracle9iAS (9.0.2.0.0) Containers for J2EE].server.http.HttpRequestHandler.processRequest(HttpRequestHandler.java:735)
         at com.evermind[Oracle9iAS (9.0.2.0.0) Containers for J2EE].server.http.AJPRequestHandler.run(AJPRequestHandler.java:151)
         at com.evermind[Oracle9iAS (9.0.2.0.0) Containers for J2EE].util.ThreadPoolThread.run(ThreadPoolThread.java:64)

    Hi Bhasker
    Try setting idleTimeOut under connection element in server configuration file to a large value.
    Regards
    Sripathy

  • Getting timeout error while updating a record from c#

    Hi,
    I have around 30k records in a tables. When I update that record inside the Transaction (Enterprise Data Library, c#) , it takes long time and throws timeout error.
    But I am able to update the same record via Toad.
    In the morning I tried same updating the record, it works without any change in the code or script.+
    is it due table lock or db related issue? please adivse, how to resolve if occurs again.
    anand

    Code:
    private static void Save()
    using (DBTransactionManager dbTransactionManager = new DBTransactionManager())
    try
    DataTableDAL.Instance.ExecuteDML("Update Voyage SET BallastBonus = 30000 WHERE ID = 'AE53B610BEA743EC8AFBAED0C8349BF8';");
    //commit database
    dbTransactionManager.Commit();
    catch
    dbTransactionManager.RollBack();
    throw;
    Table
    Column Name     ID     Pk     Null?     Data Type     Default     Histogram     Encryption Alg     Salt
    ID     1     1     N     NVARCHAR2 (32)          None          
    CALCNUMBER     2          N     NUMBER (10)          None          
    CURRENCYID     3          N     NVARCHAR2 (32)          Frequency          
    CALCTYPE     4          N     NUMBER (5)          Frequency          
    ESTIMATEDESCRIPTION     5          Y     NVARCHAR2 (200)          None          
    ESTIMATEGROUPDESCRIPTION     6          Y     NVARCHAR2 (200)          None          
    BALLASTBONUS     7          Y     NUMBER (12,2)          None          
    BALLASTBONUSCOMMPCT     8          Y     NUMBER (6,3)          None          
    ISESTIMATE     9          N     NUMBER (1)          None          
    ADDITIONALSTEAMVALUE     10          Y     NUMBER (8,4)          None          
    ISADDITIONALSTEAMPCT     11          Y     NUMBER (1)          None          
    ADDITIONALPORTVALUE     12          Y     NUMBER (8,4)          None          
    ISADDITIONALPORTPCT     13          Y     NUMBER (1)          None          
    CREATEDBY     14          N     NVARCHAR2 (32)          Frequency          
    CREATEDDATE     15          N     DATE          None          
    UPDATEDBY     16          Y     NVARCHAR2 (32)          None          
    UPDATEDDATE     17          Y     DATE          None          
    LUMPSUMCARGOCOST     18          Y     NUMBER (1)          None          
    BUNKERPRICEMETHOD     19          Y     VARCHAR2 (30 Byte)          None          
    INCCONTCALCRESULT     20          Y     NUMBER (1)          None          
    FINAL_EST     21          Y     NUMBER          None          
    SPOT_VOYAGE     22          Y     NUMBER (1)          None          
    ISRUNCOSTEDIT     23          Y     NUMBER (1)          None          
    Index
    Table doesnt have any index, except primary key index.
    Total Records
    35,000
    Hope this input might sufficient to help me.

  • Open socket timeout error

    Sometime I can write to the local shared variable through data socket. But sometime cannot. Even though, I still can read/write through shared variable monitor.
    The error is in the open socket, said connect to peer timeout. I set timeout to 10s or left blank both not work.
    I am using 8.2.1 on vista. The computer has 2 lan ports.
    I met almost same case long time ago. I solved it by diable NETBIOS and one of the lan port.
    This time, I disabled netbios already. But in vista, seems not able to disable the other lan port.
    Any suggestion?

    hi turbot,
    I had same problem of timeout error.just check if system Firewall is on or off if it is on then make it off and then run the program.i don't know how much this will help you,it helped me.
    GAK
    Gaurav k
    CLD Certified !!!!!
    Do not forget to Mark solution and to give Kudo if problem is solved.

  • Why do i keep getting the "internet connection timeout" error message?

    i have been upgrading a few standard itunes albums to itunes plus versions through my 3g mobile broadband connection, while not exactly a fast process, it was working fine until i started to get a backlog of 3 or 4 albums which were waiting in a queue to be downloaded, now every time i do the "check for downloads" option i get the "internet connection timed out" error message...this has been going on for 2 days! am i right in suspecting the backlog of albums is too much for my 3g mobile broadband connection? this is really doing my head in, if any of you techies could help me, it'd be much appreciated...?

    yes i have recently updated to itunes 8.2.1, but i am starting to think its apple's servers (i tried to download at my brothers house...different computer and connection...same connection timeout error), because it will still let me download an album, but not necessarily all of the tracks. when i questioned itunes customer services about the seemingly hit and miss state of affairs with downloading, they told me to wait 3 weeks before trying to download the tracks that were giving me the grief (2 tracks from an arctic monkeys album)...which kinda indicates they know there is a problem and are trying to fix it, why else would they say wait 3 wks??? they gave me 5 free music tracks too, which is handy.

  • Multi-Camera-Link Vision Acquisition using .avi

    So I'm trying to use two Camera-Link Cameras (JAI CM-200-MCL) with the NI PCIe 1430 frame grabber in order to obtain video of a y-axis tensile testing project, and I'm relatively new to the whole LabVIEW experience. Essentially, I want to be able to capture every image of the testing process, so I can correlate the tensile testing results with specific images using the same sample clock, (e.g. data taken at 30 seconds match the image taken at 30 seconds). I'm trying to put everything together in piece and I already have a fairly stable, working tensile testing program written for LabVIEW 2009. I'm now in the process of using IMAQ (4.4) to track these images and save them as a .avi file. I've provided some sample code -- although it currently isn't working -- that's very simplistic.
    Questions:
    1. Is there an even simpler way?
    2. Can I sync the tensile testing VI and the Vision VI by placing the Vision VI in the Tensile Testing VI inside an event structure that's triggered by the "start" button. (Boolean)
    Thanks 
    Attachments:
    Vision Acquisition.vi ‏199 KB

    lyncheb,
    How accurately do you want your test and images to by synchronized (second, millisecond...)?  If you only need to be accurate to around 1 second then software timing would work.  However if you need sub milisecond accuracy you will want to use hardware triggering.  The 1430 is capable of hardware triggering over a RTSI line.  See page 16 (2-4) of the user manual here: http://www.ni.com/pdf/manuals/372016a.pdf
    What kind of data are you logging?  What hardware / software are you using to log this data?
    Regards,
    Sam K
    Applications Engineer
    National Instruments

Maybe you are looking for

  • Installing InDesign Only from Creative Suite Disk

    I wish to Install  InDesign ONLY from my Creative Suite 2 Disk. I have The full Creative Suite 4 collection of applications installed on my Mac Pro. It resides on my NEW main hard drive. All of my copy of Creative Suite 2 was lost as per the drive fa

  • Why firefox cannot save print file in win64 bit?

    In this windows ,I cannot save any print file.(like Adobe PDF,XPC Document Writer,...) my computer goes to hang.(unknown problem) before I can type file name to save my computer. But I can print web page to my printer. So I reset print config in abou

  • RH HTML 10 - My RH7 arabic project not handling italic tags in RH10

    After upgrading a project from RH7 to RH10, the Webhelp output for Arabic is not handling italic text that was accepted previously. Image below shows "boxes" circled in red on the left for RH10 output, vs. good RH7 output circled on the right. I'll b

  • How do I rest tools in Illustrator?

    My pen tool looks like an "X" instead of an ink pen. It's frustrating me! Please tell me how to rest it back to default?

  • HANDLING YEAR

    Hi to all plz tell me in the database i have order creation date in yyyy-mm-dd format. At selection screen i am giving fiscal year bkpf-gjahr. I want report according to fiscal year. How to compare year and date. plz help me out. thanks...