Wait step error

Hi everyone,
I am using a simple wait step in my work flow . It is a wait for Event step. It is a oo event . So i have added the class to my work flow container. And used it in my wait step . When i test the work flow it throws me the error "Error when processing node '0000000204' (ParForEach index 000000)" . What could be reason for this. Can anyone help me to solve this issue.
Thanks & Regards,
Kevin.

Hi Karri,
I have done the thing as u told.... i have created a method with a returning parameter of the same class type that i use ....and with in this method i have done the following
  DATA : LCL_INST TYPE REF TO ZCL_CRM_WF.
  CREATE OBJECT LCL_INST.
  EV_ZCL_CRM_WF = LCL_INST.
Is this correct? ......Then i have used this method in my work flow...binding EV_ZCL_CRM_WF to my container element which is also of the same class type....is this all u expected me to do....if so it gives me the same error that i mentioned in the start of this thread....help me........
Thanks & Regards,
Kevin

Similar Messages

  • ERROR in the wait step

    Hi all,
    I have a requirement, where automatic payment proposal goes for an approval process. When the proposal has created in the tcode F110 based upon user who has loged in a push button "Trigger Workflow" will appear once proposal is made (enchansment), When the user press this button workflow will be triggered using the function module. After that i am finding the approver details. After this step type, i am checking for the condition (payment or proposal) if it is proposal flow will proceed futher. After this i have used a fork step - two branches 1. for the workflow proceed further 2. cancle the workflow when and event "ZSAVE_ON_CLICK" (custome defined event) is triggered.
    I am getting the error at this wait step. The error is ""Workflow 000000703573 wait step 0000000248: No valid object ID in container element 'ZbusF110'""
    Thing i have done.
    1. I check the binding, here i am passing two key values of the bo to my workflow container from the event container.
    2. When i tried to bind the EVTOBJECT to zbusf110 - it is giving me an warining "'_EVT_OBJECT' is not an export element and hence sometimes has no defined value"
    Kindly help me in solving this issue.
    Thanks and Regards
    Balaji K.

    It is working fine

  • Using WAIT step in Sync/Async Bridge

    I am using a sync/async bridge and placed a 1 minute wait step in between my async send and async reply.  When I test my process, the async reply comes in but then my 1 minute wait eventually times out and gives me an error.  Can someone guide me in fixing this BPM design (which steps to add and how)?
    http://webpages.charter.net/kpwendel/bpm_with_wait.jpg
    I would like it to stop waiting once the async reply comes in and not timeout.  If the 1 minute mark comes and a reply never came in, it would also be nice to send back an error message.
    Thanks!

    I pulled my WAIT task and had this scenario working a week ago.  I have not made any changes, but now my inbound replies to close the BPM and link up to the request are not "linking".  The request is eventually timing out even though the reply with a good correlation id comes in successfully.  Any suggestions?
    UPDATE:  I went through my objects in the IB:Config and resaved/activated them and now it is working.  Don't know what messed them up in the first place.
    Message was edited by: Keith Wendel

  • BPM(with wait step) calling another BPM

    Hello,
    I have this scenario whereby i need to call a BPM from another BPM process. Call it BPM1 and BPM2. BPM1 will have a Sync-Send-step to call BPM2.
    The following is what i have setup:-
    Working OKAY:-
    BPM1 (receive from file, send syn step to BPM2) --> BPM2(receive step (Open S/A Brige) from BPM1, send step (Close S/A Bridge))
    But if i put an wait step (for 1 minute, see below) before the send syn step in BPM1, i will have problem and the queue in BPM1 show "STOP" and the BPM2 queue show "RETRY".
    Problem:-
    BPM1 (receive from file, wait step, send syn step to BPM2) --> BPM2(receive step (Open S/A Brige) from BPM1, send step (Close S/A Bridge))
    Yes, the RETRY will work but the problem is, my BPM1 has already timeout and has ERROR (see from SWWL) and BPM2 has exceptional error in the Close A/S Bridge send step (because it can't send back to BPM1).
    Anyone has any idea how to resolve this? and hopefully the above is clear enough to discribe the problem that i'm facing now.
    Any suggestions are welcome, scott.

    The minimum BPM-wait duration is 1 min and cannot be decreased below that....

  • Wait step in BPM stops the process permanently

    Hi all.
    I have a BPM with a Wait Step inside. When the process reaches the wait step the process gets locked permanently.
    I execute TCODE SM12, remove the lock for the process and the process finishes without errors.
    Why does the BPM hangs with the wait step? Could anybody help me with this issue.
    Thanks a lot,
    Gari.

    Hi Gökhan.
    I'm using SP12. The Self-test about BPE in RWB reports error for "Schedule Background Job for Packaging" and "Schedule Background Job for Reorganization". Details for the error say "Background job for packaging is not required".
    Thanks,
    Gari.

  • Wait step in leave workflow wait for 20 min

    hi friends
      I have designed a multilevel ESS leave workflow. After 1st approver the status need to change from approved to sent after that i am using a wait step with condition REQ.STATUS = SENT. This condition is met immediately but it still waits there nearly 15 to 20 min after that only it goes to the next approver. I dont no y its happening even after the condition is met. There is background job SWWCOND is directly related to this wait step. I have scheduled this job for every 3 min. But its long time to execute. If i remove the wait step its shows dump. How to minimize the time of execution of the wait step.
    Regards
    vijay

    Hello,
    Let me know if I've understood the problem correctly.
    You have a workflow with two wait steps.
    These wait steps rely on the running of SWWCOND
    to check if the conditions have been satisfied.
    The workflow takes 15-20 mins to pass the first condition, even
    when already true, but takes little or no time to pass the second
    condition.
    SWWCOND is scheduled to run every 3 mins and doesn't run for more
    than a couple of minutes.
    My questions:
    - Are you absolutely certain SWWCOND runs every 3 minutes?
      Do you see that happening in SM37 while your workflow is waiting?
    - You've said that the first condition is REQ.STATUS = SENT,
      what is the second condition?
    - Is REQ.STATUS a virtual attribute?
    - Where is REQ.STATUS set to SENT? Outside of the workflow?
      Does it do so without an error? Is a commit work done?
    regards
    Rick Bakker
    Hanabi Technology

  • Wait step in quality is waiting for long time

    hi friends
      I have transported the workflow to quality. Am using a wait step in my workflow. Its waiting in that step for long time nearly 1 hour still its not cross the step. The workflow works fine in my developement. But in quality its not moving to the next step. i comparted the wait step in quality and developement. In developement wait step in outcomes tab green light is glowing in Actvie mode. but in quality green light is visible but in blured vision. even i have checked the configuration in swu3 in development and quality. Both have same configuration. What could be the problem that its not crossing the wait step. Plz help me
    Regards
    vijay

    hi Pavan
      I havn't used any deadline. Its working fine in development. y in quality its not working. That is my question. Even i have checked in the development wait step from the log i have these 3 steps for histroy
    Wait step created                                No errors
    Condition for wait step fulfilled               No errors
    Result Processing                               No errors
    But in quality
    Wait step created                                No errors
    Only these step is alone there. its has not yet come to other step. But my condition is fullfilling has i checked from the container elements. Am waiting for more than 3 hours. Still its not come to next step. y what could be the reason.
    Regards
    vijay

  • Wait Step, Exception Handling, Alerts

    Hi Everybody,
                 I am implementing a BPM scenario. I have a few questions:
    1) The wait step i am using in BPm, allows me the min wait time as 1 min, can't I have lesser wait time then that. Lets say 30 secs.
    2) Under what conditions should I use exception handling and when should i use alerts.
    Regards,
    Ashish

    Dear Ashish,
    1) In BPM  the 60 secs is the minimum  possible  one till now.
    2) Exceptions :
       Assume when the condition happend to  divide  by  ZERO we have to go for exceptions it to control the break of the conditions and getting the system into HANG.
    3) Alerts :
      We  use Alerts  When any error  message happen to  flow , Particularly  for Support  team information, If  they  check the mail or Alert  messages they  will come to know  where or exactly  which interface  is throwing or flowing  the error  messages.
    Regards
    Agasthuri Doss

  • Wait Step is taking more time than specified

    Hi All,
    I have included wait step for 1 minute in BPM. But it is taking more than 30 minutes instead of 1 minute.
    Could any one help me on this?
    Help will be rewarded.
    Thanks & Regards,
    Jyothi.

    Hi,
    Chech if all the jobs are scheduled correctly in SWF_XI_CUSTOMIZING if u find any jobs in error status just perform an Automatic BPM Customizing.
    refer my wiki... [BPM Trouble Shooting Deadline Step|https://wiki.sdn.sap.com/wiki/display/XI/BPMTroubleShootingDeadlineStep]
    ~SaNv...

  • Wait step stops during PI BPM workflow

    Hello Guys,
    I'm testing the one BPM scenario in my test system, during runtime the workflow stops before wait step (only 1 min) but after 1 min the message not process and it is stucked in  'in process' state.
    Earlier the scenario works good with wait step, but now it's not working in Dev & test systems but only working in Production system,
    Note: Recently we migrated from Service pack upgraded from PI 7.31 SP06 to SP11 in all three systems.
    Do you have any idea on this error?  could you please suggest me
    Thank you.
    Sateesh

    Hello Udo,
    You are absolutely right, I reschedule my background jobs in t.code SXMB_ADM_BPE then it resolved my issue.
    And I have one more question currently my PI systems are in 7.31 SP11 and getting error ' Cache content Obsolete' (SXI_CACHE-->deltaMonitoring)
    Could you please provide me any suggestions on this .
    Thank you.
    Sateesh

  • Event triggerred before Wait step

    What can we do when the event is triggerred before the wait step? Does anyone know about the concept of parked events?
    Iam using f.m swe_event_create, can we use the start_with_delay option or some other option..
    I would like to have some delay before the second event is raised. but at the same time as this would be a online program, the user should not feel the delay..
    or the Wait step should be modified to pick up already created events..(i think this is called parked events).
    CALL FUNCTION 'SWE_EVENT_CREATE'
    EXPORTING
    *objtype =
    *objkey =
    *event =
    CREATOR = ' '
    TAKE_WORKITEM_REQUESTER = ' '
    START_WITH_DELAY = ' '
    START_RECFB_SYNCHRON = ' '
    NO_COMMIT_FOR_QUEUE = ' '
    DEBUG_FLAG = ' '
    NO_LOGGING = ' '
    IDENT =
    IMPORTING

    Hi Karri, thanks for the reply ..There is a presentation on parked events if you search the wiki and blogs on this site, you will find it but thats the only thing i have seen about it and its not really helpful.
    the problem is.. 2 Inbound idocs are created both at the same time one raises a event for workflow.. one raises a event for Wait step in the same workflow ..
    The 2 inbound F.Ms which raise the events, can error sometimes or the workflow can create a workitem before the Wait step and hang in there till its processed..(its unpredictable which one will trigger first)
    If the second event(for Wait step) is raised first and the workflow processing has not yet reached the Wait step, the workflow waits for the event to be raised(although the event is already there)
    Do you know of some way we can keep reprocessing until the Event receiver is found? (may be in a Raise event workflow step or in a Function Module)
    Edited by: sk123456 on Jun 5, 2010 11:47 AM

  • TS 2.0 Wait Notification Error

    Hi,
    When I'm using the "Wait" Notification in TestStand 2.0, it throws an error at runtime: "Error executing substep 'Post'. User-defined error code".
    Any ideas anyone?
    Thanks,

    Hi Tsoang,
    As you can tell from the error message, Post is a substep of the Wait step in TestStand. Have you tried to edit (customize) the Wait step or the Post substep in TestStand? Any edits could be causing a problem.
    Furthermore, it says user-defined error code, but did it give you any more information (like an error code)?
    With respect to your sequence, have you tried removing the wait step? If you do this, does your sequence execute correctly?
    Also, have you tried using the Wait step in a blank sequence? Do you still get the same error?
    The answers to these questions should help us get closer to a solution.
    Matt M.
    NI

  • Uncaught Exception: Applicatio​n Registry Wait Timeout Error Messages - BB 8703e

    Ok, I hope someone here can help me a bit more then US Cellular has done so far for this never ending problem.
    This whole problem started after I updated my BB device software and installed face book application over the weekend.  Since then my BB will not receive any data signal, however I can make phone calls still after confirming many Uncaught Exception: Application Registry Wait Timeout Error Messages. Until they start coming up again.
    Here are some steps I have already tried to correct this problem
    Remove Battery, then reboot
    Load up Blackberry Manager to restore setting -- BB Manager doesn't even seem to see it anymore when I connect it.
    US Cellular has already tried reloading the BB device software again
    Has anyone ever ran into this or a similar problem like this one and figured out a  solution to it?
    If yes Please let me know.  I don't want to end up carrying around some basic cellphone again.  I am already addicted to my crackberry.
    TIA
    Solved!
    Go to Solution.

    Greetings, and welcome to the BlackBerry.com Support Forums.
    What is the signal indicator you get from your device?
    I am trying to recall the 8703 settings, look at Options or Tools > to Mobile Network. What are you settings there?
    1. If any post helps you please click the below the post(s) that helped you.
    2. Please resolve your thread by marking the post "Solution?" which solved it for you!
    3. Install free BlackBerry Protect today for backups of contacts and data.
    4. Guide to Unlocking your BlackBerry & Unlock Codes
    Join our BBM Channels (Beta)
    BlackBerry Support Forums Channel
    PIN: C0001B7B4   Display/Scan Bar Code
    Knowledge Base Updates
    PIN: C0005A9AA   Display/Scan Bar Code

  • Reading the value of the "WaitForTarget" attribute of the Wait step

    I am trying to access the  "Step.WaitForTarget" attribute for the Wait step but can't find the correct syntax to use in an expression or the correct API calls to use in an action step.  I intend to use this in an expression as I am looking for a specific value.
    I have a object reference to the step that I am testing  (Locals.StepRef) and from that I have no issues reading the standard attributes like name, step type, preconditions, etc...
    How do we access the special additional properties of the wait step ?
    Solved!
    Go to Solution.

    Hey 4watt,
    One easy way to do this is to access the step reference as a PropertyObject and use GetValNumber to obtain the value. For example:
    Locals.StepRef.AsPropertyObject.GetValNumber("WaitForTarget",0)
    I tested this out and it does correctly return the value of WaitForTarget. Let us know if you need any more assistance!
    Daniel E.
    TestStand Product Support Engineer
    National Instruments

  • BPM wait step : RWB"To Be Delivered status": SXMB_MONI"Message being sent"

    Hi All,
    I have a BPM interface running fine since 1 year.
    In this BPM I have wait step for 5 minutes.
    But yesterday message  is stopped on wait and not proceeding ahead.
    I checked XML is good as per mapping. and in runtime wirk bench message is still in "To Be Delivered status"
    and in SXMB_MONI message column Outbound Status still showing "Message being sent" even after 12 hours.(wait is only 5 minutes). And below is the trace of last message.
    Please guide how to handle or restart this message. in SMQ1 & SMQ2 there are no queues showing:
      <?xml version="1.0" encoding="UTF-8" standalone="yes" ?>
    - <!--  Inbound Message
      -->
    - <SAP:Trace xmlns:SAP="http://sap.com/xi/XI/Message/30">
      <Trace level="1" type="T">--start determination of sender interface action</Trace>
      <Trace level="1" type="T">select interface Request_SI</Trace>
      <Trace level="1" type="T">select interface namespace https://www.XXXXX.com/YYYY</Trace>
      <Trace level="1" type="T">--start determination of receiver interface action</Trace>
      <Trace level="1" type="T">Loop 0000000001</Trace>
      <Trace level="1" type="T">select interface Request_SI</Trace>
      <Trace level="1" type="T">select interface namespace https://www.XXXXX.com/YYYY</Trace>
      <Trace level="1" type="T">--start determination of sender interface action</Trace>
      <Trace level="1" type="T">Hence set action to DEL</Trace>
      </SAP:Trace>
    Regards

    Solved, few BASIS jobs were inactive in transaction code "SWF_XI_CUSTOMIZING".

Maybe you are looking for

  • How can i unlock my iphone 4 from apple

    I'm staying in Bangladesh..... I've bought an iphone from a store near pann Station of NY.....I've asked them before buy whether it was unlock or nt...and they said it is unlocked.....After return to my country ...when i entered local sim ..seen it i

  • My BT experience

    I'd like to share my experiences with BT recently, to see if other customers have had similar struggles: 23rd Oct 2012: Placed an order for a new phoneline connection and broadband. Told the first available Openreach engineer's appointment was for 13

  • Visual Web - How to 'setObject' for an SQL query with an IN  ? clause

    Hello, I am relatively new to visual web pack. I am stuck at writing the java code for passing parameters to the SQL query. In a normal scenario, where we need to check if some variable is present in a column (= ?), we would pass the parameter as : s

  • Common Libraries are only showing up graphic symbols, nothing else

    I've created my own common library but when i retrieve it from the common libraries drop down, the library only contains  graphic symbols even though there are movie clips, bitmaps and folders in the master file. If I open up the library by importing

  • Distortion when I use peripherals???/

    Hello all! I have the iPod Classis 80 gig. When I try to use it with my JBL ipod radio or the output cable, the sound ends up with distortion. This does not occur when I use headphone. It only happens when I use the iPod connection. Is there a simple