Winsockread Error in LabVIEW PDA

Hi all. I am currently trying out the VI server example given in the LabVIEW PDA toolkit but i keep getting this error "WinsockRead error Error Code: 10054.
The LabVIEW example project I am using is "VI Server- Pocket PC.lvproj" and I have loaded the "CallByRef Wave - Pocket PC.vi"  into the PDA. I have a WIFI connection to a PC and have manually assigned IP address to both the PDA (192.168.100.101) and PC (192.168.100.100). I have verified my WIFI connection is working by using the "ping 192.168.100.101" command on my PC.
Also, I am configured my VI server correctly by selecting the enabling the TCP/IP protocol and ActiveX under the VI Server Configuration. The port number I used is 3363. I have also added the PDA IP address (192.168.100.101) to the Machine Access List.
When I try to run the example program on the PDA with the IP address "192.168.100.100" and a port number of 3363, I will get the error. Can anyone give advice on what I have missed out or done wrongly?
I forgot to mention that the remote program "TargetWave.vi" on the PC is loaded in memory and opened in LabVIEW also.
Thanks in advance.

D.Com,
I just thought of something else to try. You said you are using port 3363. The program was initially set up to use Port 3865. Did you change the VI server properties (From the project, right click on the my computer icon>>properties>>VI server: Configuration) to port 3363 or just the control on the front panel of the CallByRef Wave.vi? Both must be set to the same port.
Secondly, you may have to open a port in your firewall if you are using WindowsXP SP2. Initially I would completely disable the firewall and see if that solves the problem. If it does, then enable the firewall and create an exception of the port you've specified (3363).
As for using the trial version, this should have no impact on the performance of the toolkit.
Best Regards,
Chris C
Applications Engineering
National Instruments
Chris Cilino
National Instruments
LabVIEW Product Marketing Manager
Certified LabVIEW Architect

Similar Messages

  • Error for LabVIEW PDA Module Version 8.5

    Hi all
            I am face on with problem when i try to do the LabVIEW PDA Module Version 8.5 Tutorial which is include in labVIew software package.All my lincence status also activated and do install all the accessories that i need.I follow all the steps by tutorial sheet.But i still face on with problems, so now i would like to uninstall my LabVIEW software and reinstall again.The error is as shown in attach file. i want to know is there any problem if i uninstall my software? If anyone can show me why the error is? The technician said even though the error come out, just close and wait for about 5 min.After 5 min already the emulator will be come out.But mine haven't comeout.So please any one can show me?
    Thanks a lot
    Best Regards
    Nyan Lin
    PS: The tutorial that i do is as shown in attach file.
    Attachments:
    PDA_Getting_Started.pdf ‏452 KB
    error14.JPG ‏119 KB
    error8.JPG ‏131 KB

    Hi Stephan
                      Thanks for giving your time for me. I am a new LabVIEW PDA Module user.And I have to do it because of my final year project.I am student from Nanyang Polytechnic (Singapore). I never use labVIEW software and LabVIEW PDA Module software before.This is my first time. The software that i have is LabVIEW Version 8.5. So as what you say is i need to reinstall my the whole LabVIEW PDA Module and all start again? Then i know that for PDA Module i need to download Virtual PC2007.But what else i still need to install? The Window Mobile 5.0 emulator and the rest softwares is it include in the LabVIEW PDA Module software package? If not, please let me know which software i still have to download? Then i go and check the software status that i have and the lincense status is as shown in attach files.Thanks for giving your time and help me.
    With Regards
    Nyan Lin
    Attachments:
    Software status.JPG ‏72 KB
    Lincense.JPG ‏98 KB

  • Tab Control Property Node gives a build error when used in a VI for LabVIEW PDA

    Hello,
        Iam new to LabVIEW development & need help regarding this:
        We are trying to port a LabVIEW application from desktop to a Windows Mobile PDA. Please note that the LabVIEW application works fine on the desktop. In one of the VIs, a Tab control property node is used which gives a build error with LabVIEW PDA project. A sample VI which shows the problem & the error list snapshot is attached with this post. Can anyone please suggest an alternate approach to achieve the same functionality with LabVIEW PDA? Waiting for an early response from anyone...
    Thanks & Regards,
    Subhashini
    Attachments:
    VI_Error.zip ‏31 KB

    Hello Ton,
        Am glad that i got a response, thanks. The following links indicate that Tab control is supported on PDA target:
    http://digital.ni.com/public.nsf/allkb/CBA335641E27B858862571490015EA88?OpenDocument
    http://forums.ni.com/ni/board/message?board.id=170&message.id=221507&requireLogin=False
        I feel that the Tab control property node that has been used in the VI (which is attached earlier) may not be supported on the PDA target. Can u (or any LabVIEW expert) suggest an alternate approach to achieve the same goal with LabVIEW PDA (changing colour of Tab control pages programatically)??
        I had missed out some details earlier: We are using LabVIEW 8.5 PDA module on a Windows Mobile PDA.
    Thanks & Regards,
    Subhashini

  • LabView PDA module gives error "unable to lock memory chunk"

    I've written a LabVIEW PDA Application that reads an ASCII decimal string through a PDA serial port. I can display the string ok, but when I try to convert the string to a number using the decimal string to number VI I get the error message "App failed. Error Code 172649003. Unable to lock memory chunk."
    Any ideas?
    Cheers, Paul
    Naval Surface Warfare Center - Carderock Division
    West Bethesda, MD

    Does this happen whenever you use the string to number VI (can you reproduce this in an empty VI)?
    Are you sure it happened because of that VI and not because of something else that is happening in the VI at the same time?
    Can you cut down pieces of the code and still get the error? Can you post a small example?
    Which PDA\LV are you using?
    Can you write some more details about your app (does it do anything else other than serial comm)?
    Try to take over the world!

  • LABVIEW PDA/DAQmx Base error

    I'm building a VI for a PDA (pocketPC 2003)
    In a Functions Panel, when I'm going in a menu "Measurement I/O" => "DAQmx Base", it misses many icons. I have installed and uninstalled three time DaqmxBase 2.2 with the same result (icon.jpg). I have installed Daqmx Base 3.0 and the problem is always there. Moreover, when I'm going in menu "Select VI" in a Functions Panels, I can open anothers Daqmx Base VI, but there is many errors (error.jpg).
    Labview 8.2.1
    Labview PDA 8.2.1
    DAQ6062E
    Attachments:
    error4.JPG ‏108 KB
    icon.JPG ‏130 KB

    Hi,
    LabVIEW PDA support for DAQ is limited.  The number of DAQ VI's available on LabVIEW PDA is also limited. 
    I could not clearly view your error list but I did run across a possibly useful Knowledge Base article. I am also including the Known Issues with LabVIEW PDA 8.2.1 . I hope this helps!
    Regards,
    Ima
    Applications Engineer
    National Instruments
    LabVIEW Introduction Course - Six Hours
    Getting Started with NI-DAQmx

  • LabVIEW PDA gives error 12 when opening file

    I can create a file with LabVIEW PDA with Pocket PC 2003, but when I try to open the file I always receive error 12 "Some system capacity necessary for operation is not enabled."
    Can someone help me to solve this error ?
    thanks in advance for your help.
    Nico

    On the PDA, File Open returns error 12 when you are trying to open a datalog file and the datalog type you specify on the funtion does not match the datalog type on the file header.
    Regards,
    miko

  • Error message when building an application for Labview PDA

    When using LabView PDA module to build an application for a PDA target, I receive the following message: "Error building executable. Unable to create file". Why is this happening?
    When looking at the error log, it reads "The system cannot find the file specified."
    This happens even when looking at one of the Labview PDA example VI's, so it is not a result of the VI containing functions of features not supported by Labview PDA.
    When installing Labview PDA, I installed files as follows, and in this order:
    (i) Labview 7.1 (installed previously)
    (ii) Microsoft eMbedded Visual C++ 4.0
    (iii) Microsoft eMbedded Visual C++ 4.0 SP 3.0
    (iv) Microsoft SDK for Windows Mobile 2003-based Pocket PCs
    (v) Microsoft ActiveSync 3.8
    (vi) NI Labview 7.1 PDA module for PocketPC
    (vii) DAQmx Base 1.0 for PDA or later
    Any ideas?

    Did you attempt to add the _wordsub.llb and _excelsub.llb files to the application as support files?  I believe in LabVIEW 8.0 instead of adding the entire LLBs you should just add the _Word Dynamic VIs.vi and _Excel Dynamic VIs.vi as dynamic VIs.  I think I've seen a similar post on the discussion forums in the past that recommended this.
    If this suggestion doesn't help, please reply, and attach a simple VI and .lvproj file demonstrating the problem so I can investigate further.
    Good luck,
    -D
    Darren Nattinger, CLA
    LabVIEW Artisan and Nugget Penman

  • LabVIEW PDA reports COREDLL.DLL error when using Call Library Function Node

    I'm trying to build a LV PDA app that calls an external DLL file built using embedded visual C. When configuring the Call Library Function node I select the stub DLL, configure the I/O parameters and select OK. When the configuration dialog closes I get the following error:
    LabVIEW: LabVIEW.exe - Unable to Locate Component
    This application has failed to start because COREDLL.DLL was not found. Re-installing the application may fix this problem.
    I do not get this error when using the configuration dialog in the example VIs.
    Any suggestions as to the cause and/or the solution?
    Thanks,
    Ryan

    Hello -
    When you create a PDA VI that calls a DLL, you must include the .c or .lib file that corresponds to the DLL. Take a look at these documents:
    LabVIEW PDA Module Build Errors with VIs that Call DLLs
    Why Do I Receive Errors When Calling a C++ DLL from a Call Library Node Using the LabVIEW PDA Module...
    How To Call External Code in LabVIEW PDA for Palm OS
    H
    ow To Call External Code in LabVIEW PDA for Pocket PC
    Hope this helps!
    S Vences
    Applications Engineer
    National Instruments

  • Is it possible to run AM Modulation in LabVIEW PDA Module?

    Hi All,
            I would like to ask about AM Modulation vis can run on PDA Module or not?Because as i mention that PDA screen is too small to see all the AM modulation waveforms.So i would like to know whether is it pissible to run AM Modulation on the LabVIEW PDA Module? If it is possible, please tell me that how should i modified my VIs on block diagram and how do i arrange all waveforms graph on front panel?
            Then, the AM modulation that i want to run is as shown in attach file.
             Thanks to all for your help.
    With Regards
    Nyan Lin
    Attachments:
    AM block Diagrams.jpg ‏56 KB
    AM Modulation front panel.jpg ‏107 KB

    Hi Jpaul,
                 Thanks for your quite useful help. I am now able to manage all waveform in one tab control. But i still have some errors for my final year project. I am from Singapore Nanyang Polytechnic who do the final year project. My project is to transfer over the AM Modulation waveforms on the PDA device. But i still face on with some errors.My error is as following.
    (1) After i run my waveforms together with Tab control, the program that appear on the PDA is only too small and only can see half of
          my waveform.As i understand that all the text size must be greater than 20. And I chose the landscape screen for my tab control using.
          The waveform that together with tab control is as shown in attach file.
    (2) Then my PDA's internal memory is not enough space for running the new application and when i want to delete it, it is not possible to
          delete and there is error to delete. I would like to know how can i delete my NI files from my memory. My PDA model is HP iPAQ hx2700.
    (3) Then I would like to know more about what is the usage of NI CF-6004?  Is it like memory card for running NI
          waveforms on the PDA? Or if not what is it use for ?
                 I am strongly appreciate for ur help and i know that this might be so many question. But i am really no way to find this errors anymore.Thats why i have to ask to you. I will be thanks for all ur help. Thanks a lot
    Best Regards
    Nyan Lin
    Attachments:
    AM Modulation on PDA.JPG ‏30 KB

  • Error when building PDA project 'Unsupported control - Knob, 680'

    Hi,
    I'm developing an application for my PDA (8.2 LabVIEW version) which was in the past running in my laptop with the 7.1 version of LabVIEW. I'm working step by step and as soon as I inserted an own subVI an error occur. This own subVI containes also other own subVI but everything was working perfectly on my laptop. So I just provide you a picture of the error window, hoping somebody already encounters this kind of message.
    Thanks
    Attachments:
    LabVIEW PDA error.jpg ‏541 KB

    LabVIEW PDA do not allow using the same variety of functions and controls as the PC versions. You should rework your "faulty" vis by replacing the original controls with the available PDA controls (and functions). When developing for a PDA, avoid as much as possible prototyping on a LV PC version... Good luck !
    Chilly Charly    (aka CC)
             E-List Master - Kudos glutton - Press the yellow button on the left...        

  • Command line arguments with a Labview pda applicatio​n

    Hi Everyone,
    I am in the process of writing some Labview code to run on a PDA that is called from another vendor's software. When called, I need to pass some information to it (in the form of an integer) and then return an error code when it has finished its task (again, as an integer).
    Not being able to compile a my application as a labview dll for to run on a PDA with Windows Mobile 2003, I was hoping to be able to pass command line arguments to my program when compiled as an executable. This doesn't seem to be possible.
    Could someone please confirm that Labview PDA applications do not support command line arguments?
    Any suggestions on how to meet my objective would be most welcome .
    Regards,
    Mark

    Paolo,
    Thanks for your input: storing this information in a text file is a choice we are looking at. But it does leave us with the problem that the vendor's software will not necessarily know when our program has finished running, unless it continuously polls the file to see if there has been any update.
    A dll would be ideal. I was hoping there might be a clever way of emulating this.
    Regards,
    Mark.

  • How to build a dll for labview pda, which uses the intel ipp primitives in it

    Hi all,
    For my application, I need to call a c dll from Labview PDA, and in the c function i need to use intel IPP function. When i call my dll, i get an error saying the ippfunction i use, say "ippsCopy_16s missing c or vi file". Can someone tell  me what I might be doing wrong?

    Hi Vani,
    When using a DLL in a PDA there are some special considerations you have to take. Please take a look at the following knowledgebase describing the process.
    Eli S.
    National Instruments
    Applications Engineer

  • Error when running PDA application with emulator

    Hi,
    I receive my LabVIEW PDA Module yesterday and I tried to realise the Tutorial. I don't have any problem to make it work on the PDA but I always have a error message when I want to use an emulator (see the attached file for the message).
    One more information, the driver requires according to the message is installed.
    Thank you.
    Attachments:
    NI_LABVIEW8.20.jpg ‏86 KB

    Hi Roberto,
    I saw this message when I first used the PDA emulator but installing VPC resolved it.  Are you able to launch the emulator outside of the LabVIEW context?  The emulator manager should be at this location:  C:\Program Files\Microsoft Device Emulator\1.0\dvcemumanager.exe .  You can use the emulator manager to launch specific emulators by right-clicking on them and selecting "Connect".
    Also, have you attempted to uninstall and reinstall VPC?  You should be able to remove it from the Add/Remove Programs dialog.  You can then download a fresh copy here.
    If you are still having problems after trying these things, you may want to check out or post to the Microsoft Device Emulator Forum. Especially check out this thread about "Failed to open VPC Network driver".
    Hope this helps!
    Spex
    National Instruments
    To the pessimist, the glass is half empty; to the optimist, the glass is half full; to the engineer, the glass is twice as big as it needs to be...

  • How to create a login interface in labview PDA module?

    How to create a login interface in labview PDA module? So that it checks with a list of usernames and passwords and allow to go to another VI?
    Anu

    Anu,
    I've attached a really short example that does something like what you're talking about.  It just compares the user's username and password a pre-determined username and password and then "logs the user in" based on that comparison.  Like Greycat said, you probably want to store this username and password info in some sort of file on the PDA that's in an encrypted format for both security and flexibility of your application.
    I hope this helps,
    Justin D.
    Applications Engineer
    National Instruments
    Attachments:
    LoginVI.vi ‏17 KB

  • Labview pda module: how can I resize image dynamicall​y in an applicatio​n?

    Hello every one,
     I am currently working on the development of an application on a PDA (brand Nomad) and whose OS is Windows Mobile. So I am using the PDA module of Labview 8.6.My problem is the following one: in my application I would like to be able to load images (thanks to their path) in pictures indicators. I load images with the labview “function PDA Image File Load.vi” and then my problem is that images don’t fit with the size of the indicator, and so I am only able to see the left top corner of the image…Of course, I would like to see the entire picture, but I don’t know how I can modify or resize a picture with the PDA Module, where most of the property nodes (zoom factor, scrollbars…for picures) are not available.Has someone ever faced and fixed that problem?? Any help would be really appreciated!!   PS: Attached is one part of my application!
    Attachments:
    cameracapture.vi ‏21 KB

    Hi,
    Indeed, like Romain D. said you have some interesting discussions where you can find some customer's experience like yours :
    How Do I Put A Picture or Image On My LabVIEW PDA for Palm Front Panel?
    How to Resize a picture 
    Scale image on PDA (Pocket PC)
    Placing an image or picture on Labview PDA pocket PC 
    Picture and PDA 
    PDA Picture Control Scrollbars
    Let me know what happens.
    Regards,
    Steve M.
    National Instruments France
    #adMrkt{text-align: center;font-size:11px; font-weight: bold;} #adMrkt a {text-decoration: none;} #adMrkt a:hover{font-size: 9px;} #adMrkt a span{display: none;} #adMrkt a:hover span{display: block;}
    >> Vidéo-t'chats de l'été : présentations techniques et ingénieurs pour répondre à vos questions

Maybe you are looking for

  • Trying to install Adobe Acrobat X Pro and it will not install.

    It says "the wizard was interrupted before Adobe Acrobat X Pro could be completely installed." Not sure what is interrupting the installation. It is a PC with Windows 7 64-bit. I tried installing twice already.

  • I can only get sound using Apple's Headphones. Help?

    Okay, this is weird. I had no sound, or so I thought. However, now my ipod does have sound, but only through apple's headset. If I plug in any working headphone set, I get nothing but silence, but if I use the apple headset, I get sound. This is also

  • Newbie ? - Creating Grid Lines On JSVGCanvas?

    Hi All- I'm new to Swing and would really appreciate any assistance anyone could give me with this. I would like to create some grid lines as a background on a JSVGCanvas for some Icons that will be populated on the canvas when the Icon is selected f

  • Nokia 5000d-2 Issue

    Hello everyone, I have a problem with my 5000d-2, when somebody calls me, the phone displays only the phone number of the person that's calling me, although I have that person in my contact list (phone memory not sim). Can somebody guide me trough th

  • Airport Extreme/Airport Express

    If someone could confirm what I think I have been reading, but still am not sure, I will gladly reward points..... If I want to have my Airport Extreme set up as N only, then I can't connect my Airport Express solely for the purpose of using Airtunes