1 logical drive failed

hi,
i am facing a problem in my HP ML150 G1 Server with two SCSI Hard drives with RAID 1, creating problem no ligical drives detection.
Error showing
SCSI IDs are not responding 0 3 4
1 logical drive found on the host adaptor 
1 logical drive failed 
1 logical drive handled by Bios
plz help 

Hi.
You can try to upgrade to the latest controller firmware version by downloading this iso.
https://software.cisco.com/download/release.html?mdfid=281021974&flowid=45824&softwareid=283046733&release=2.9%281%29&relind=AVAILABLE&rellifecycle=&reltype=latest
Instructions and release notes here http://www.cisco.com/web/software/283046733/92252/FWUCD-2.9.1-H-README.pdf
HTH
Regards
Carlo

Similar Messages

  • My 2008 Macbook Pro logic board failed...am I still able to copy that hard drive onto my 2011 Macbook Pro hard drive?

    My 2008 Macbook Pro logic board failed...am I still able to copy that hard drive onto my 2011 Macbook Pro hard drive?

    What you can do is to extract the hard drive from your old computer, put it in an enclosure and connect it to your newer computer, so you can restore your data.
    It's not too difficult to do it yourself, but if you think you will do something wrong, take it to a store where you can get your data restored

  • Failed to create RAID logical drive WAE-7371-k9

    hi all  we have cisco wae-7371-k9 , we wanna recreate RAID device using cd recovery. we booting on cd, and when we done with option numbers 2,3,5 succes but when we came on option 7, we cannot recreate RAID, it failed, following the log: Installer Main Menu:     1. Configure Network     2. Manufacture flash (done)     3. Install flash cookie     4. Install flash image from network     5. Install flash image from cdrom     6. Install flash image from disk     7. Recreate RAID device (WAE-674/7341/7371 only)     8. Wipe out disks and install .bin image     9. Exit (Eject and reboot) Choice [0]: 7 Recreate RAID device option is selected   All disk data will be lost.   Are you sure you want to recreate RAID array? [n]: y Saving random seed... dd: opening `/state/random-seed': No such file or directory   No volume groups found Controllers found: 1  All data in logical drive 1 will be lost. Deleting: logical drive 1 ("")  Command completed successfully. Controllers found: 1  A selected physical drive is not available for use.  Command aborted. Failed to create RAID Logical drive. (1,2)     MODEL: OE7371    FLASH: found, directory validated   COOKIE: valid    IMAGE: 4.3.5.7 FLASHDEV: /dev/sda  what's wrong with wae ?if we run command show disk detail, all hard disk detected    NO-HOSTNAME# sh disk det  RAID Physical disk information:   disk00: Ready                      JTX1470L    286102 MB   disk01: Ready                      JTX1B24L    286102 MB   disk02: Ready                      JTX1B9SL    286102 MB   disk04: Ready                      JTWSEBWL    286102 MB   disk05: Ready                      JTX0VYRL    286102 MB  RAID Logical drive information:  Mounted file systems:  MOUNT POINT      TYPE       DEVICE                SIZE     INUSE      FREE USE%  Disk encryption feature is disabled.  can you help, what's the problem .?

    Budi,
    Please turn off the unit, make sure you reseat the disks and then try the CD-recovery in the following way:
    2,3, 5,8,7,8, remove the disk and 9
    Please log the session then we can see how it went
    Hope this helps!
    Jorge

  • Logical drive 1 status = Ready for recovery ml350 g5

    Hi,
    I have a problem with a HP Proliant ML350 G5, 2 weeks ago the server did shutdown unexpectedly i looked in the ACU and saw that the controller had a battery problem. I replaced the battery but the server keeps once or twice a day shutting down. I made a report from the ACU but i don't know what this all means.
    Here is a part of the report, i hope someone can lead me to the right solution,
    Thanks in advance.
    Array Diagnostic Utility Version 7.85.16.0
    Array Diagnostic Utility Inspection Report Version 7.85.16.0
    Date/Time:          Friday, June 27, 2014 3:43:11PM
    Computer Model:     HP Server
    SLOT SUMMARY:
       Slot Num  Slot Type  Array Controllers and Host Adapters Detected
       SLOT 0    PCI        Smart Array E200i Controller
    SLOT 0 Smart Array E200i Controller ERROR REPORT:
       Logical drive 1 status = Ready for recovery
    SUBSYSTEM INFORMATION:
       Chassis Serial Num:              GB87494LT1
       This Controller
          Array Serial Number:          QT79MU6382    
          Cache Serial Number:          P9A3A0B9SV00ST
       Other Controller
          Array Serial Number:          Not Available
          Cache Serial Number:          Not Available
    CONTROLLER IDENTIFICATION:
       Configured Logical Drives: 1
       Configuration Signature:   0xa00004c9
       Controller Firmware Rev:   1.66
       Controller ROM Revision:   1.66
       Controller Hardware Rev:   0x00
       Boot Block Version:        1.66
       Board ID:                  0x3211103c
       Cable or Config Error:     0x00 (No)
       Invalid Host RAM Address:  No
       CPU Revision:              0x00
       CPU to PCI ASIC Rev:       0x00
       Cache Controller ASIC Rev: 0x00
       PCI to Host ASIC Rev:      0x00
       Marketing Revision:        0x41 (Rev A)
       Expand Disable Code:       0x01
       Protocol Chip Count:       1
       Enclosure Count:           3
       Max SCSI IDs per Bus:      0
       Big Drive Map:             0x000c 0x0000 0x0000 0x0000 0x0000 0x0000 0x0000 0x0000
       Big Ext Drive Map:         0x0000 0x0000 0x0000 0x0000 0x0000 0x0000 0x0000 0x0000
       Big Non-Disk Drive Map:    0x0000 0x0000 0x0000 0x0000 0x0000 0x0000 0x0000 0x0000
       Fibre Chip Count:          0
       Recovery ROM Inactive     
       Image Revision:               
       Recovery ROM Active Image 
       Flags Status:              0x10
       Battery PIC Rev:           0x20
       NCQ:                       Not Supported
    LOGICAL DRIVE IDENTIFICATION:
       Logical Drive 1:
          Sector Size:              512
          Sectors Available:        143305920
          Fault Tolerance Mode:     Mirroring
          Logical Param Table:      cyl=17562 heads=255 sec/track=32 xlate sig=0x0
          BIOS Disabled:            No
          Logical Drive Ident:      0x       0
          Logical Drive Label:      A00004C9QT79MU6382     678E
    LOGICAL DRIVE CONFIGURATION:
       Logical Drive 1:
          Configuration Signature:  0xa00004c9
          Mapping Scheme:           Multiple Block
          Physical Drives:          2 (number not valid after drive movement)
             This Logical Drive:    2 (excluding spare drives)
          Fault Tolerance Mode:     Mirroring
          Logical Param Table:      cyl=17562 heads=255 sec/track=32 xlate sig=0x0
          Distribution Factor:      256
          Operating System:         64768
          Controller Order:         0
          Additional Information:   0
          Offset to Data:           0
          Int 13h Support Enabled:  Yes
          Sectors on Volume:        143305920
          Sectors per Drive:        143305920
          Big Drive Assignment Map: 0x000c 0x0000 0x0000 0x0000 0x0000 0x0000 0x0000 0x0000
          Big Spare Assignment Map: 0x0000 0x0000 0x0000 0x0000 0x0000 0x0000 0x0000 0x0000
          Array Accelerator is enabled for this logical drive.
    LOGICAL DRIVE STATUS:
       Logical Drive 1:
          Drive Status:           Ready for recovery
          Blocks to Rebuild:      0
          Blocks Re-mapped:      
          Spare Status Flags:     0x00
          Spare to Replaced Map:  See Big Spare to Replace Map:
          Media Was Exchanged:    No
          Cache Failure:          No
          Expand Failure:         0x00
          Unit Flags:             0x00
          Big Remap Count:        All Counts Zero
          Big Drive Failure Map:     0x0000 0x0000 0x0000 0x0000 0x0000 0x0000 0x0000 0x0000
          Big Replacement Drive Map: 0x0004 0x0000 0x0000 0x0000 0x0000 0x0000 0x0000 0x0000
          Big Active Spare Map:      0x0000 0x0000 0x0000 0x0000 0x0000 0x0000 0x0000 0x0000
          Big Spare to Replace Map:  No spares have replaced any drives
          Big Spare Marked OK Map:   0x0000 0x0000 0x0000 0x0000 0x0000 0x0000 0x0000 0x0000
    MONITOR AND PERFORMANCE DATA:
       Port 1I, Box 1, Bay 2
          Factory:     Serial #, Firmware Rev, and Mfg/Model #:
             33 4e 50 32 34 36 59 30 30 30 30 30 39 38 31 36      3NP246Y000009816
             51 35 58 4e 48 50 44 37 00 00 00 00 48 50 20 20      Q5XNHPD7....HP 
             20 20 20 20 44 47 30 37 32 41 42 41 42 33 20 20          DG072ABAB3 
             20 20 20 20 00 00 00 00 00 00 00 00 00 00 00 00          ............
             00 00 00 00                                          ....
          Since Power: Serial #, Firmware Rev, and Mfg/Model #:
             33 4e 50 32 34 36 59 30 30 30 30 30 39 38 31 36      3NP246Y000009816
             51 35 58 4e 48 50 44 37 00 00 00 00 48 50 20 20      Q5XNHPD7....HP 
             20 20 20 20 44 47 30 37 32 41 42 41 42 33 20 20          DG072ABAB3 
             20 20 20 20 00 00 00 00 00 00 00 00 00 00 00 00          ............
             00 00 00 00                                          ....
          Serial Number Control:     0x0054
          Firmware Revision Control: 0x0248
          Mfg/Model Number Control:  0x0268
                     Factory          Since Power      Threshold        Control
          Serv. Time 00341415         000001d4         00000000         2104
          Read Blks  0000001788c34d46 00000000000002b1                  0108
          Hrd Read   00000485         00000000         00000000         2104
          Rtry Read  00000000         00000000         00000000         2104
          ECC Read   000000000000000d 0000000000000000 0000000000000000 2108
          Write Blks 00000006c04e371c 0000000000ffcf08                  0108
          Hrd Write  00000000         00000000         00000000         2104
          Rtry Write 00000006         00000000         00000000         2104
          Seeks      0000000000000000 0000000000000000                  0808
          Seek Errs  0000000000000000 0000000000000000 0000000000000000 0808
          Spin Cyls  00000000         00000000         00000000         2104
          Spin Time  0000             0000             0000             2202
          Test 1     0000             0000             0000             0802
          Test 2     0000             0000             0000             0802
          Test 3     0000             0000             0000             0802
          Test 4     0000             0000             0000             0802
          Spare Blks ffffffff         ffffffff                          0a04
          Re-mapped  0000009b         00000000         00000000         2504
          DRQ Tmots  0000             0000             0000             0802
          Timeouts   0000             0000             0000             2102
          Rebuilds   0002             0000             0000             2102
          Spn Retrs  ffff             ffff             0000             2902
          Fl Rd Recv 0000             0000             0000             2102
          Fl Wt Recv 0000             0000             0000             2102
          Format Err 0000             0000             0000             2102
          POST Err   0000             0000             0000             0802
          Drv Nt Ry  00000000         00000000         00000000         2104
          Reallc Abt 00000000         00000000         00000000         0804
          IRQ Gltchs 00000000         00000000         00000000         0804
          Bus Flts   00000054         00000001         00000000         2104
          Hot Plgs   00000000         00000000         00000000         2104
          Tk Rwt Err ffff             ffff             0000             2902
          Rmp Wt Err 0000             0000             0000             2102
          Bg Fw Rev  0000000000000000 0000000000000000                  0848
          Med Flrs   0000             0000             0000             2102
          Hrdw Errs  0007             0000             0000             2102
          Abt Cmd Fl 0000             0000             0000             2102
          Spn Up Fl  0000             0000             0000             2102
          Bd Tgt Cnt 0000             0000             0000             2102
          Pred Fails 00000000         00000000         00000000         2104
          DRIVE ERROR LOG:
             Error Log Header:
                Parameter Length    = 0x14
                Entry Size          = 0x0040
                Current Entry       = 0x1c
                Total Errors Logged = 0x0000021c
             Error Log Data:
    SCSI  CAM   Sense  Sense
    Stat  Stat  Key    Code    Qual   Block(Vl)       Time       Op   Info
    02    04    06     29      02     00000000(0)     002f200b   00   0000
    02    04    06     29      02     00000000(0)     002f477e   00   0000
    02    04    06     29      02     00000000(0)     0030a78b   00   0000
    02    04    06     29      02     00000000(0)     00311fd3   00   0000
    02    04    06     29      02     00000000(0)     00316ebf   00   0000
    00    0a    00     00      00     00000000(0)     00317117   00   0000
    02    04    06     29      02     00000000(0)     0032043a   00   0000
    02    04    06     29      02     00000000(0)     00329e1f   00   0000
    02    04    06     29      02     00000000(0)     0032c9aa   00   0000
    02    04    06     29      02     00000000(0)     0033b5c4   00   0000
    00    0a    00     00      00     00000000(0)     0033e304   00   0000
    00    0a    00     00      00     00000000(0)     0033e430   00   0000
    00    22    00     00      00     3f000000(0)     0033e509   5a   0000
    00    0a    00     00      00     00000000(0)     0033eec2   00   0000
    00    0a    00     00      00     00000000(0)     0033f285   00   0000
    00    0a    00     00      00     00000000(0)     0033f4f2   00   0000
    00    0a    00     00      00     00000000(0)     0033f6d2   00   0000
    00    0a    00     00      00     00000000(0)     0033fe90   00   0000
    00    0a    00     00      00     00000000(0)     0034003c   00   0000
    00    0a    00     00      00     00000000(0)     003402d0   00   0000
       Port 1I, Box 1, Bay 1
          Factory:     Serial #, Firmware Rev, and Mfg/Model #:
             33 4e 50 32 46 41 57 38 30 30 30 30 39 38 33 30      3NP2FAW800009830
             32 39 41 52 00 00 00 00 00 00 00 00 48 50 20 20      29AR........HP 
             20 20 20 20 44 47 30 37 32 41 42 41 42 33 20 20          DG072ABAB3 
             20 20 20 20 00 00 00 00 00 00 00 00 00 00 00 00          ............
             00 00 00 00                                          ....
          Since Power: Serial #, Firmware Rev, and Mfg/Model #:
             33 4e 50 32 46 41 57 38 30 30 30 30 39 38 33 30      3NP2FAW800009830
             32 39 41 52 48 50 44 43 00 00 00 00 48 50 20 20      29ARHPDC....HP 
             20 20 20 20 44 47 30 37 32 41 42 41 42 33 20 20          DG072ABAB3 
             20 20 20 20 00 00 00 00 00 00 00 00 00 00 00 00          ............
             00 00 00 00                                          ....
          Serial Number Control:     0x0054
          Firmware Revision Control: 0x0248
          Mfg/Model Number Control:  0x0268
                     Factory          Since Power      Threshold        Control
          Serv. Time 00055b43         000001d4         00000000         2104
          Read Blks  000000029c28733f 0000000001e70b56                  0108
          Hrd Read   00000000         00000000         00000000         2104
          Rtry Read  00000000         00000000         00000000         2104
          ECC Read   0000000000000000 0000000000000000 0000000000000000 2108
          Write Blks 00000000c7b62ee8 0000000000ffcf36                  0108
          Hrd Write  00000000         00000000         00000000         2104
          Rtry Write 00000000         00000000         00000000         2104
          Seeks      0000000000000000 0000000000000000                  0808
          Seek Errs  0000000000000000 0000000000000000 0000000000000000 0808
          Spin Cyls  00000000         00000000         00000000         2104
          Spin Time  0000             0000             0000             2202
          Test 1     0000             0000             0000             0802
          Test 2     0000             0000             0000             0802
          Test 3     0000             0000             0000             0802
          Test 4     0000             0000             0000             0802
          Spare Blks ffffffff         ffffffff                          0a04
          Re-mapped  00000000         00000000         00000000         2504
          DRQ Tmots  0000             0000             0000             0802
          Timeouts   0000             0000             0000             2102
          Rebuilds   0001             0000             0000             2102
          Spn Retrs  ffff             ffff             0000             2902
          Fl Rd Recv 0000             0000             0000             2102
          Fl Wt Recv 0000             0000             0000             2102
          Format Err 0000             0000             0000             2102
          POST Err   0000             0000             0000             0802
          Drv Nt Ry  00000000         00000000         00000000         2104
          Reallc Abt 00000000         00000000         00000000         0804
          IRQ Gltchs 00000000         00000000         00000000         0804
          Bus Flts   00000004         00000001         00000000         2104
          Hot Plgs   00000000         00000000         00000000         2104
          Tk Rwt Err ffff             ffff             0000             2902
          Rmp Wt Err 0000             0000             0000             2102
          Bg Fw Rev  0000000000000000 0000000000000000                  0848
          Med Flrs   0000             0000             0000             2102
          Hrdw Errs  0000             0000             0000             2102
          Abt Cmd Fl 0000             0000             0000             2102
          Spn Up Fl  0000             0000             0000             2102
          Bd Tgt Cnt 0000             0000             0000             2102
          Pred Fails 00000000         00000000         00000000         2104
          DRIVE ERROR LOG:
             Error Log Header:
                Parameter Length    = 0x14
                Entry Size          = 0x0040
                Current Entry       = 0x1f
                Total Errors Logged = 0x0000001f
             Error Log Data:
    SCSI  CAM   Sense  Sense
    Stat  Stat  Key    Code    Qual   Block(Vl)       Time       Op   Info
    02    04    06     29      02     00000000(0)     00000000   00   0000
    02    04    06     29      02     00000000(0)     00000001   00   0000
    02    04    06     29      02     00000000(0)     00006731   00   0000
    02    04    06     29      02     00000000(0)     00008ea4   00   0000
    02    04    06     29      02     00000000(0)     0001eeb1   00   0000
    02    04    06     29      02     00000000(0)     000266f9   00   0000
    02    04    06     29      02     00000000(0)     0002b5e5   00   0000
    02    04    06     29      02     00000000(0)     0002b83d   00   0000
    02    04    06     29      02     00000000(0)     00034b60   00   0000
    02    04    06     29      02     00000000(0)     0003e545   00   0000
    02    04    06     29      02     00000000(0)     000410d0   00   0000
    02    04    06     29      02     00000000(0)     0004fcea   00   0000
    02    04    06     29      02     00000000(0)     00052a2a   00   0000
    02    04    06     29      02     00000000(0)     00052b56   00   0000
    00    22    00     00      00     3f000000(0)     00052c2f   5a   0000
    02    04    06     29      02     00000000(0)     000535e8   00   0000
    02    04    06     29      02     00000000(0)     000539ab   00   0000
    02    04    06     29      02     00000000(0)     00053c18   00   0000
    02    04    06     29      02     00000000(0)     00053df8   00   0000
    02    04    06     29      02     00000000(0)     000545b6   00   0000

    Hi QUANT,
    Your Proliant server is a commercial product and to get your issue more exposure I would suggest posting in the commercial forums. Here is a link to the Commercial Notebook forum.
    Thank you,
    Please click “Accept as Solution ” if you feel my post solved your issue.
    Click the “Kudos Thumbs Up" on the right to say “Thanks” for helping!
    Thank you,
    BHK6
    I work on behalf of HP

  • How to remove a disk from a logical-drive in a 3510

    Hello SUN masters,
    I have a 3510 with 4 logical drives and 2 global spares. Logical drive 0 (ld0) has 14 disks and i want to assign 2 of those as global spares and leave ld0 with 12 drives. the other logical-drives have just 2 HDD so I won't touch them.
    Drives are 78 GB and ld0 is supposed to have 476 GB, so space is enough with 12 HDD to have RAID1.
    What is the procedure to remove a disk from a logical drive. when i telnet to the 3510 there is no option to remove a disk from a ld, only to add disks to logical-drives.
    when i use sccli to access the 3510, i can't see an option in the menu.
    Does anyone know the steps?
    I copy below the configuration of this 3510.
    Thanks a lot,
    OM
    sccli> show disks
    Ch Id Size Speed LD Status IDs Rev
    2(3) 0 68.37GB 200MB ld0 ONLINE SEAGATE ST373207FSUN72G 055A
    S/N 4735V4FS
    WWNN 2000001862560447
    2(3) 1 68.37GB 200MB ld0 ONLINE SEAGATE ST373207FSUN72G 055A
    S/N 4735V3MA
    WWNN 200000186256037C
    2(3) 2 68.37GB 200MB ld0 ONLINE SEAGATE ST373207FSUN72G 055A
    S/N 4735V4E8
    WWNN 20000018625601EE
    2(3) 3 68.37GB 200MB ld0 ONLINE SEAGATE ST373207FSUN72G 055A
    S/N 4735SWZZ
    WWNN 20000018625600B3
    2(3) 4 68.37GB 200MB ld0 ONLINE SEAGATE ST373207FSUN72G 055A
    S/N 4735V3K8
    WWNN 2000001862560DD9
    2(3) 5 68.37GB 200MB ld0 ONLINE SEAGATE ST373207FSUN72G 055A
    S/N 4735V5RE
    WWNN 200000186250FD75
    2(3) 6 68.37GB 200MB ld0 ONLINE SEAGATE ST373207FSUN72G 055A
    S/N 4735SHSL
    WWNN 2000001862560E21
    2(3) 7 68.37GB 200MB ld1 ONLINE SEAGATE ST373207FSUN72G 055A
    S/N 4735V3HK
    WWNN 2000001862560340
    2(3) 8 68.37GB 200MB ld1 ONLINE SEAGATE ST373207FSUN72G 055A
    S/N 4735VRLS
    WWNN 200000186250FDD9
    2(3) 9 68.37GB 200MB ld2 ONLINE SEAGATE ST373207FSUN72G 055A
    S/N 4735VACF
    WWNN 200000186250FF21
    2(3) 10 68.37GB 200MB ld2 ONLINE SEAGATE ST373207FSUN72G 055A
    S/N 4735V3MN
    WWNN 2000001862560338
    2(3) 11 68.37GB 200MB ld0 ONLINE SEAGATE ST373207FSUN72G 055A
    S/N 4735V3LB
    WWNN 2000001862560393
    2(3) 16 68.37GB 200MB ld0 ONLINE HITACHI HUS1073FASUN72G 2A08
    S/N 51RWUAVL
    WWNN 2000000087A06F78
    2(3) 17 68.37GB 200MB GLOBAL STAND-BY HITACHI HUS1073FASUN72G 2A08
    S/N 51RWUM51
    WWNN 20000000879FEE53
    2(3) 18 68.37GB 200MB ld0 ONLINE HITACHI HUS1073FASUN72G 2A08
    S/N 51RWULUZ
    WWNN 2000000087A04C50
    2(3) 19 68.37GB 200MB ld0 ONLINE HITACHI HUS1073FASUN72G 2A08
    S/N 51RWULX2
    WWNN 2000000087A04D47
    2(3) 20 68.37GB 200MB ld0 ONLINE HITACHI HUS1073FASUN72G 2A08
    S/N 51RWUAYG
    WWNN 2000000087A05A9F
    2(3) 21 68.37GB 200MB ld0 ONLINE HITACHI HUS1073FASUN72G 2A08
    S/N 51RWULJE
    WWNN 2000000087A0480A
    2(3) 22 68.37GB 200MB ld0 ONLINE HITACHI HUS1073FASUN72G 2A08
    S/N 51RWULP4
    WWNN 2000000087A017F1
    2(3) 23 68.37GB 200MB ld3 ONLINE HITACHI HUS1073FASUN72G 2A08
    S/N 51RWULKH
    WWNN 20000000879FF323
    2(3) 24 68.37GB 200MB ld3 ONLINE HITACHI HUS1073FASUN72G 2A08
    S/N 51RWUM17
    WWNN 2000000087A05214
    2(3) 25 68.37GB 200MB ld4 ONLINE HITACHI HUS1073FASUN72G 2A08
    S/N 51RWUPU5
    WWNN 2000000087A04D44
    2(3) 26 68.37GB 200MB ld4 ONLINE HITACHI HUS1073FASUN72G 2A08
    S/N 51RWUAYJ
    WWNN 2000000087A03A83
    2(3) 27 68.37GB 200MB GLOBAL STAND-BY HITACHI HUS1073FASUN72G 2A08
    S/N 51RWUB26
    WWNN 2000000087A07653
    sccli> show logical-drives
    LD LD-ID Size Assigned Type Disks Spare Failed Status
    ld0 44D2C94E 476.81GB Primary RAID1 14 2 0 Good
    Write-Policy Default StripeSize 32KB
    ld1 7703C275 68.12GB Primary RAID1 2 2 0 Good
    Write-Policy Default StripeSize 32KB
    ld2 41803916 68.12GB Primary RAID1 2 2 0 Good
    Write-Policy Default StripeSize 32KB
    ld3 0B192FEE 68.12GB Primary RAID1 2 2 0 Good
    Write-Policy Default StripeSize 32KB
    ld4 4DE9645E 68.12GB Primary RAID1 2 2 0 Good
    Write-Policy Default StripeSize 32KB
    sccli>

    The only solution you have is:
    - Backup the data.
    - Remove the LD.
    - Recreate the LD with 12 drives.
    - Restore the data.
    Although you can add physical drives into a LD, you cannot remove them from a LD, unless you go through a backup/restore.

  • Partition logical drive storedge 3310

    Hi
    I have Sun storedge 3310 version 413B, i create logical drive in Raid 5 configuration:
    LD LD-ID Size Assigned Type Disks Spare Failed Status
    ld0 68EB1906 272.46GB Primary RAID5 5 1 0 Good
    and i need create 16 partitions on it, but i can create only 7 partitions:
    * partitions
    LD/LV ID-Partition Size
    ld0-00 68EB1906-00 14.00GB
    ld0-01 68EB1906-01 14.00GB
    ld0-02 68EB1906-02 14.00GB
    ld0-03 68EB1906-03 14.00GB
    ld0-04 68EB1906-04 14.00GB
    ld0-05 68EB1906-05 14.00GB
    ld0-06 68EB1906-06 14.00GB
    ld0-07 68EB1906-07 14.00GB
    How i can create other eight partitions on ld0; i need create this configuration:
    ld0-00 68EB1906-00 14.00GB
    ld0-01 68EB1906-01 14.00GB
    ld0-02 68EB1906-02 14.00GB
    ld0-03 68EB1906-03 14.00GB
    ld0-04 68EB1906-04 14.00GB
    ld0-05 68EB1906-05 14.00GB
    ld0-06 68EB1906-06 14.00GB
    ld0-07 68EB1906-07 14.00GB
    ld0-08 68EB1906-08 14.00GB
    ld0-09 68EB1906-09 14.00GB
    ld0-0a 68EB1906-0A 14.00GB
    ld0-0b 68EB1906-0B 14.00GB
    ld0-0c 68EB1906-0C 20.00GB
    ld0-0d 68EB1906-0D 20.00GB
    ld0-0e 68EB1906-0E 20.00GB
    ld0-0f 68EB1906-0F 20.00GB
    ld0-10 68EB1906-10 24.46GB
    any idea?....thanks

    If you are using lun mapping to create your partitions, (done by using telnet to the array and then selecting "View and Edit Host Luns") you have to tell the array the maximum numbers of luns you can create. Some systems will only let you create one by default and you can't make any changes to the size of the lun you are trying to present to your host. There is an option when you telnet to the box in the controller area for the maximum number of luns you can create. Luns in this case are partitions.
    If you are not trying to partition your logical drive by using lun mapping, I don't know what your problem is.
    Stephen

  • Dynamic Smart Array B220i RAID Controller keeps loosing Logical Drive after power shutdown.

    Hi, I own two HP Microservers Gen8. I added SSD drive on the DVD SATA port in both. I created Raid 0 over the SSD Drive that I can boot from it, but everytime I shutdown the box (power outage), the logical drive is lost. Note that the logical drive is not lost on reboot. Only when the box is is shutdown. Any ideas why is this happening? Here are repro steps: Enter Smart Storage Administrator
    Select onDynamic Smart Array B220i RAID CtrollerClick on "Unassigned Drive" Screen shows me:SATA HDD:
    - 3TB Port1:Bay1
    - 3TB Port2:Bay2 SATA SSD
    - 120GB Port5:Bay5 I selected Sata SSD drive in Port5:Bay5I clicked on "Create Array"
    On a next screen I select the following:
    I selected RAID 0, 256 KiB Stripe Size, 32 Sectors, Maximum Size
    I click on "Create Logical Drive" On a next screen:
    A message: Logical Drive was successfully created.
    I click on Finish
    I exit the Smart Storage Manager and reboot the system. The server boots from the Raid0 Array (Sata SSD Drive in Port5:Bay5) -> No problem If I just reboot the server, it boots from the Raid0 Array. - No problemIf I shut down the server (or during Power outage), the Smart Array tells me that there is no logical array during the boot. The boot fails. -> Qualifies for a problem.
    Please can you explain why is the logical drive lost after power loss? Why the controller does not remember the setting? Other details:- Dynamic Smart Array B220i RAID Controller (v3.54.0)- When I boot to Smart Storage Administrator after power failure, I can recreate the Raid 0 over the SSD drive and boot again - this a work around the issue. Thank you for your advise.Jiri 

    Hi QUANT,
    Your Proliant server is a commercial product and to get your issue more exposure I would suggest posting in the commercial forums. Here is a link to the Commercial Notebook forum.
    Thank you,
    Please click “Accept as Solution ” if you feel my post solved your issue.
    Click the “Kudos Thumbs Up" on the right to say “Thanks” for helping!
    Thank you,
    BHK6
    I work on behalf of HP

  • Adaptec 2820SA Logical Device Failed

    System: WinXP SP2
    Supermicro X6DAE-G2
    2 x Xeon CPU 3.40 GHz
    8 x Western Digital Caviar RE 400GB SATA
    Adaptec 2820SA
    Bios: b11564
    Driver: b11737
    Configuration:
    4 RAID 0 Arrays (2 disks in each array)
    Problem:
    Playing Quicktime files causes a "Logical device failed", independent of the file or which array the file is located on.
    Fortunately, the the device can be "Forced online" using Adaptec Storage Manager.
    I, naively, thought that this would be a problem Adaptec would be concerned with, unfortunately, Adapetc claims that this is a problem with the Quicktime software. But my RAID just crashed...
    I would appreciate any work around to this problem.
      Windows XP  

    Hi ,
    Rerun the BDLS again as this took very little time.
    When you try to run again it popsup message saying it already exists just delete that and again put the Logical system name and run it will run that time.
    May be while scheduling the job you gave for spool I am not sure why is it looking for Printer which is locked.
    Thanks.

  • My hard drive failed and I can't afford the professional data recovery.  Do I have any other options?

    I have a 13" Early 2011 Macbook Pro.  Last week the hard drive failed (for the second time), and when I took it to the Apple Store I was told it would cost $177 to replace the hard drive and the cables.  I intend on going through with this and getting it fixed, however the man I talked to said I should hold on to it a little longer before giving it to them for repair in case I want to recover my data.  When I researched how to recover the data, my answers mostly consisted of taking it to a professional to do so.  I found a local authorized service provider who said they could do so, however I was told it would cost at least $400 to recover my data (possibly more depending on how much data there is to recover).
    I can afford to pay $177 to fix the hard drive.  I cannot, however, afford to pay an additional $400+ to get all of my data back.  Yes I realize I should have backed my files up onto an external hard drive (I'm not the most computer-savvy person), but honestly, all I really need is my photos.  When my hard drive was in the process of failing, I got a flash drive and put a lot of my files onto it so I would at least have some of them when I got my Macbook fixed.  At this point, I can't even turn it on, so I am not able to go into iPhoto and get my pictures.
    Is there any way I can do this myself?  There is no way I can get this done professionally.  I would love to be able to all of my data and files back, but if I can just get some that is better than nothing.  Any help would be appreciated!

    obesity wrote:
    It was really empty. Clicked on, nothing.
    But no prohibited signs, like these:
    Get info on folder, zero kb. Just one user account on each mac.
    I did navigate back several days prior to my Mac dying. Still nothing.
    Sounds like it may have been excluded, or perhaps damaged. 
    Just for future reference, it's always a good idea to keep "secondary" backups.  See #27 in Time Machine - Frequently Asked Questions for some suggestions.

  • Logical drive partition not showing in Mac OS.

    Hi all,
    I'm rather new to mac OS and am hoping someone could help me out with this problem.
    I've a windows partition (C:) running Vista Ultimate. In it, I had created 'logical drive' which contains a FAT32 (D:)and a NTFS (E:)partition. I'm thinking of using this 'D:' drive to share data between vista and Mac OS. However, when I boot up into Mac OS, both d: and e: drives are not showing (c: showing thought). I went into Terminal and use the 'diskutil list' command, it doesn't show me my D: and E: partition.
    Can anyone help?
    Thanks,
    Simon

    MacDrive7 allows 32-bit Windows to access r/w to HFS+.
    There is a Google kit for NTFS.
    I had terrible performance and luck with Paragon Software's NTFS for Mac OS X 6.0 ($30) and would not recommend it.
    If you are willing to start over, clone your Vista. Maybe WinClone or Norton Ghost.
    Reformat your internal drive with Disk Utility after backing up (Apple Disk Utility Restore).
    Don't use BootCamp and create Vista NTFS, FAT32 and Mac OS X. Don't install or restore OS X until AFTER you have Vista installed.
    BootCamp only allows for a 2nd partition and I'm not a fan of its methods and limitations.

  • My 5 year old iMac's hard drive is at the point of failing.  I'm trying to save al files on it, but it wont allow backup via Time Machine to an external hard drive.  How can I keep from losing all the files and programs if the hard drive fails?

    I'm concerned that my iMac, purchased 5 years ago, is about the crash and I can't back up my files and programs to an external hard drive via Time Machine because the computer freezes after only a couple hundred MB and gets nowhere near the required amount.
    How can I save these files and programs if the computer hard drive fails or has to be replaced without the backup being able to be done? I need to do something quickly, but I'm not sure what I can or should be doing.

    Get an external hard drive, some good ones that I like are the OWC, http://www.macsales.com Mercury Elite Pro drives...they are very good and reasonably priced.
    Get the drive, connect via USB or FireWire, then use Disk Utility to format the new drive as Mac OS X Extended (Journaled), and then use Disk Utility to Restore the current drive to the new drive.  Restore actually clones the drive so you will have a bootable backup on the external drive.
    After you have formatted and named the external drive, click Restore in the main Disk Utility window, drag the name of the old hard drive to the Source box, and drag the name of the new external drive to the Destination box.  DU will make an exact clone of the internal drive on the external drive.
    That clone will be a complete backup of the operating system and all of your data.
    You can test it by restarting the iMac and hold the Option key.  That will give you a grey screen showing all bootable drives.  Just click the external drive, then click the upward pointing arrow under it and the iMac will boot from that drive.

  • I have a 27" imac (intel) my hard drive failed and I installed a new one. This is my first time dealing with this so I am having trouble re-installing the OS. Install disc spits out and ? mark with folder appears what am I missing?

    Like the title says. My 1 TB drive failed and unfortunately my computer isn't covered on the replacement program even though my hard drive is the one they are claiming to replace. So that is not a solution just to get that out of the way. So I replaced the hard drive. What I am having trouble with is re-installing my OS. I have 10.6. When I load it and restart it just spits it out and I get the question mark folder. What am I doing wrong is there a step I'm missing? I did do a back up to my Time Machine before the crash. Can I plug it into it and reload format? I'm new to this so any help would be appreciated.
    Thanks!

    Well, let's hope that nothing was jiggled out of place when you were installing the new hard drive. Your optical drive may just be out of alignment or the disc you have is "dirty." Get a lint-free cloth and some rubbing alcohol, then clean the disc as thoroughly as you can starting from the center and working outward in a concentric circlular motion. See if that helps. In particular clean the inner portion well.
    If this does not help, then you have a problem. You have opened the computer yourself. That action voids all support from Apple. If you take the computer in for service the store may refuse to service the computer. This is not related to your now expired warranty.

  • I have a version Adobe pro 7, my old computer hard drive failed tried to install on my Windows 8.1, will not start up error message

    I have a version Adobe pro 7.1, my old computer hard drive failed, tried to install on my Windows 8.1, will not start up get error message? any solutions?  It worked perfectly fine on my old computer which was windows 7.0

    Hey,
    I am sorry but Acrobat 7 is not at all compatible with Windows 8. For this, you will need to upgrade your Adobe Acrobat version.
    For better understanding, please refer this kb file:
    Compatible web browsers and PDFMaker applications
    Regards,
    Anubha

  • Network drives fail (drives used to share databases among multiple computers)​.

    I am using databases on multiple computers to store test results for a production line. The computers share info from thier databases with each other using dsn's made with the ODBC Windows XP Admin Tool (Control Panel). This works well most of the time but occasionally one of the network drives fails - I have to disconnect and then use ODBC to make a new connection (a new dsn). Why are the network drives failing? Should I use somenthing else that is more reliable? datasocket? Shared Variable? [email protected]

    Gary MavSysInc,
    When you say that your program fails, are you referring to the same thing as your LabVIEW Application that is reterieving data? If so, what do you mean by it fails? Is there an error message? Does it Crash? What happens when it "fails"?
    Ben Sisney
    FlexRIO V&V Engineer
    National Instruments

  • Macbook Pro Hard Drives Failing

    Hi all,
    I've been having massing problems with my Macbook Pro 15" 2.53 Ghz laptop. I got one brand new with apple care in December of 2008. The hard drive was the standard 320 Gb @ 5400 RPM.
    Within approximately two weeks of operation the computer failed (froze and after a hard shutdown wouldn't boot). It turned out the hard drive failed. Two weeks! So I took it back to Apple and they replaced the hard drive (took them one week so I lost a week of productivity).
    One week after receiving the laptop back, the hard drive failed again! This time I believe the OS got corrupted somehow as the symptom was that it would not boot.
    So back to Apple and they straight out replaced it with a new one. One week later, guess what? Failure. So back again and they replaced it.
    I'm now on my 3rd laptop from Apple and this hard drive is failing. Luckily I was able to back everything up. I downloaded a utility called SMART Utility and it tells me 60 some sectors are bad on this disk.
    Is anyone else having issues like this? Its absolutely ridiculous. Currently the computer is working despite the failed sectors and horrible sounds coming from the hard drive but I expect failure soon. I'll be taking this back to Apple and showing them the results of the SMART Utility, but I'm at the end of the rope here.
    I've owned multiple Macbook Pros before and absolutely loved them. But now I am so disillusioned by this... To Apple's credit they have had great customer service, but now I'm at the point where I need to be able to rely on my machine.
    Has anyone heard anything?

    I would second Michael's comment. While hard drives do fail, the rate at which yours are failing would appear to be well beyond the statistical average. I would generally think the next level would be a problem with the MacBook itself causing the failures, but from what I can tell from your comment is that they have replaced your MacBook twice (and you're on your third?). So that would seem to rule out a problem with the MacBook itself. You mentioned that you've had other MacBooks before and it doesn't sound like you've had problems with them... so I wouldn't expect that you're doing anything unusual that would cause the problem.
    You're either had a remarkable run of bad luck, or there's something going on that's out of the ordinary causing these drives to fail. I would imagine that when stores get machines, they're likely shipped from batches that are manufactured at similar times. If they had a batch of faulty drives from the manufacturer, it's possible a single store could have gotten several of them. That would still not really explain why your initially replaced drive failed as it would likely have come from a totally different batch than what would have been used in manufacturing at the time your notebook was put together. I guess it's always possible that they might put in a drive that that wasn't new.

Maybe you are looking for

  • Re: (forte-users) Minimal Fusion

    Thomas, A response which may contain no answers...and may lead to more questions... As a novice fusion user, one of the largest obstacles to using Fusion is the lack of XML API's in an application, be it a customer's in-house or vendor's software pro

  • Sap query infoset and fieldgroup

    hi cn we have more than one fieldgroup in a single infoset thanks

  • GRN - Dates

    While making GRN, currently, only posting date is picked up and stored by SAP. Along with the same, we need to feed following 2 dates whiel making GRN. Pl provide the solution. 1. Challan/Dnote Date 2. Physical Material Received date Point 2 date is

  • E_ADEPT_BAD_REQUEST_CONTENT_TYPE

    I get an error grom ACS4 for the following request. I can't find details on this error. Any help would be appreciated. <request xmlns="http://ns.adobe.com/adept" action="get" auth="builtin"> <nonce>..........</nonce> <expiration>2012-11-20T11:54:46-0

  • Why do i get an intenal error 500 message when trying to download firefox 4

    I quit using firefox some time ago when this message kept appearing. I tried to download firefox 4 today and get the same message.