2 UWL System Alias Return 2 Workitem

Dear Experts,
I am getting confuse about UWL with webflow connector configuration.
I have requirement to running standard workflow and user define workflow on SAP EP ESS/MSS.
2 System alias or landscape must be activated.
First SAP_WebDynpro_XSS, and 2nd SAP_BSP_EREC. Which is as i knew that standard workflow running on SAP_WebDynpro_XSS, whereas user define workflow running on SAP_BSP_EREC.
But Why in UWL MSS SAP EP display 2 times for each task or workitem?
I was done to define XML for Those 2 system landscape.
For User define workflow, XML configuration look like
    <ItemType name="uwl.task.webflow.TS90000085.SAP_BSP_EREC" connector="WebFlowConnector" defaultView="DefaultView" defaultAction="launchWebDynPro" executionMode="default">
      <ItemTypeCriteria systemId="SAP_BSP_EREC" externalType="TS90000085" connector="WebFlowConnector"/>
      <Actions>
        <Action name="launchWebDynPro" groupAction="" handler="SAPWebDynproABAPLauncher" returnToDetailViewAllowed="yes" launchInNewWindow="yes" launchNewWindowFeatures="resizable=yes,scrollbars=yes,status=yes,toolbar=no,menubar=no,location=no,directories=no">
          <Properties>
            <Property name="WebDynproApplication" value="ZHRWD_BEN_APPROVE"/>
            <Property name="newWindowFeatures" value="resizable=yes,scrollbars=yes,status=yes,toolbar=no,menubar=no,location=no,directories=no"/>
            <Property name="DynamicParameter" value="wi_id=${item.externalId}"/>
            <Property name="openInNewWindow" value="yes"/>
            <Property name="WebDynproNamespace" value="SAP"/>
            <Property name="display_order_priority" value="5"/>
          </Properties>
          <Descriptions default=""/>
        </Action>
      </Actions>
    </ItemType>
And standard workflow or tasks i am grouping on SAP_WebDynpro_XSS Landscape.
Can anyone help me to solve this problem?
Best Regards,
Agnis Virtinova Avency

Thanks a lot Shanti, Nice suggestion. I have been enabling support information to know which system alias or landscape had been used for each workitem.
I have 2 UWL system configuration,
1. System Alias : SAP_WebDynpro_XSS with Connector Type :  WebFlowConnector
2. System Alias :  SAP_BSP_EREC with Connector Type :  WebFlowConnector
FYI: I need to enabling leave request in ESS, so service SAP_WebDynpro_XSS must be used i think, that service refers to SAP Portal Server then SAP_BSP_EREC must be enable too for running WebDynpro Applications.
I was done to setup for separated which task ID grouping at each landscape or system alias.
But in UWL still return double workitems. Based on support information, 1 of workitems has been correct to read 1 of XML file configurations, but 1 other has information as shown below
Item Type Configuration Name: uwl.webflow
Item Type: uwl.task.webflow.default
External Item Type: TS90000085
Item Type: Associated View: DefaultView
Internal Item ID: 4207
External Item ID: 000000007540
I think uwl.webflow configuration can't be changing. There are someone to help me to explain how that system work or solution of that problem?
Thanks a lot,
Virtinova

Similar Messages

  • Unable to set property Refresh Completed Items for UWL system

    Hello Experts,
    We are on NetWeaver 7.40 SP2 and UWLJWF version is 1000.7.40.2.0.20130411234700.
    We have configured a system object with system alias SAP_ECC_HumanResources pointing to the backend ECC system.
    I am creating a UWL WebFlowConnector system with this same system alias in the UWL Administration page to fetch ABAP Workflow workitems from the backend and display those in the portal UWL.
    When I try to check the checkbox for the Refresh Completed Items: property and click Save it shows me an error message saying Could not connect to back end SAP_ECC_HumanResources to check if it supports direct custom retrieval feature.
    I have already followed the steps for Prerequisites for Enabling Refresh of Completed Items and Activation in Back-end System mentioned in the link Enabling Refresh of Completed Items but still getting the above error.
    I have also tried restarting the UWL service as given here (UWL) Error while configuring the Refresh of Completed Items Mechanism
    Can anyone give any suggestions what else needs to be checked for this property to work for the UWL system?
    Regards,
    Saurabh
    Message was edited by: Vera Gutbrod

    Hello Experts,
    I have managed to resolve this problem. The RFC Destination configured for UWL WebFlowConnector had some problems and it was not able to ping to the backend system. I got this RFC Destination re-configured and then restarted the UWL service and following this I am now able to set the Refresh Completed Items property for the UWL WebFlowConnector system.
    However now when I am trying to set a value of 30 seconds in the Delta Pull Channel Refresh Period (in Seconds): property and saving the change, I am getting a warning message The backend of system SAP_ECC_HumanResources is not configured for optimized delta pull.
    How do I go about setting this value for the delta pull refresh?
    Regards,
    Saurabh

  • Error while registering SAP ECC system in UWL systems

    hi,
    Error while registering SAP ECC system in UWL systems.
    Errors:
    System R3Production: Thu Nov 27 16:12:05 GMT+05:30 2008
    (Connector) :com.sap.netweaver.bc.uwl.connect.ConnectorException:Thu Nov 27 16:12:05 GMT+05:30 2008
    (Connector) :com.sap.mw.jco.JCO$Exception:Connect to SAP gateway failed
    Connect_PM  TYPE=A ASHOST=132.147.0.112 SYSNR=00 GWHOST=132.147.0.112 GWSERV=sapgw00 PCS=1
    LOCATION    CPIC (TCP/IP) on local host with Unicode
    ERROR       partner '132.147.0.112:sapgw00' not reached
    TIME        Thu Nov 27 16:12:05 2008
    RELEASE     700
    COMPONENT   NI (network interface)
    VERSION     38
    RC          -10
    MODULE      nixxi.cpp
    LINE        2823
    DETAIL      NiPConnect2
    SYSTEM CALL connect
    ERRNO       79
    ERRNO TEXT  A remote host refused an attempted connect operation.
    COUNTER     2
    Item type retrieval and registration requires a connection to the systems and may take a couple of minutes
    For each system, they are generated as the configuration named 'uwl.webflow.<system_alias>' or 'uwl.alert.<system_alias>'.
    After configuration changes in the backend system, you must re-register the system.
    regards.
    Srinivas.

    Hi,
    you can check few things prior proceeding:
    Does your connector test after adding your backend system in portal works fine?
    Did you define a system alias?
    Make sure your SSO is working,
    Also check your Jco detination webdynpro tab.
    Regards,
    Vamshi.

  • UWL system creation error?

    Hi,
    I'm trying to setup UWL configuration for ESS/MSS.  During minimal configuration of UWL setup, I'm assigning one of the system alias which is connecting to the R3 system using SAPLogonTicket method.  We got same uid maintained in portal and ECC6. 
    I defined UWL system and when I clicked on Register button, I get below message
    (Connector) :com.sap.netweaver.bc.uwl.connect.ConnectorException:
    (Connector) :com.sap.portal.connectivity.destinations.PortalDestinationsServiceException:User is missing credentials for connecting to alias UWL_System. Contact your system administrator.
    OK, then I wanted to test the connection of system object that is used by UWL. WebAS, ITS connection tests are successfully, but "Test connection with connector" failed with below error
    Test Connection with Connector
      Test Details:
    The test consists of the following steps:
    1. Retrieve the default alias of the system
    2. Check the connection to the backend application using the connector defined in this system object
      Results
    Retrieval of default alias successful
    Connection failed. Make sure that Single Sign-On is configured correctly
    As suggested in this thread which was posted  by me sometime ago
    Standard UWL configuration error?
    I tried to use System Administrator >> Support >> SAP Transaction >> choose the system aliase that is used for UWL and entered SU01 tcode, it pops with windows for UID/PWD, why is this happening even when all the parameters are correctly defined in System object?
    Thanks
    Praveen

    Hi Geet,
    I still have no luck.  I tried exactly what you said and followed all notes.  Here are the steps that I followed and error message
    1) UWL_Service user didn't exist in the R3, so created and assigned roles that are required as you mentioned and as mentioned in note 873932, 1109225, 1133821, 1171615.
    2) Set up RFC destination in Visual admin and binded to the UWL_Service user for system_alias$WebFlowConnector.  In my case the system alise is SAP_ECC_HumanResources. 
    3) Restarted the server.
    4) Configured new UWL system with SAP_ECC_HumanResources system alise.  Click register button I got below error
    Error in retrieving logical system id for system SAP_ECC_HumanResources:
    com.sap.portal.connectivity.destinations.PortalDestinationsServiceException: User is missing credentials for connecting to alias SAP_ECC_HumanResources. Contact your system administrator.
    User :<USER.R3_DATASOURCE.XXXXXXX> getting data from system : <SAP_ECC_HumanResources >: JCO error in checking/creating UWL service user:
    com.sap.portal.connectivity.destinations.PortalDestinationsServiceException: User is missing credentials for connecting to alias SAP_ECC_HumanResources. Contact your system administrator.
    User :<USER.R3_DATASOURCE.XXXXXXX> getting data from system : <SAP_ECC_HumanResources >: JCO error in reading configuration::com.sap.portal.connectivity.destinations.PortalDestinationsServiceException: User is missing credentials for connecting to alias SAP_ECC_HumanResources. Contact your system administrator.
    Error in loading configuration for system SAP_ECC_HumanResources:com.sap.netweaver.bc.uwl.UWLException: (Connector) :com.sap.netweaver.bc.uwl.connect.ConnectorException:(Connector) :com.sap.portal.connectivity.destinations.PortalDestinationsServiceException:User is missing credentials for connecting to alias SAP_ECC_HumanResources. Contact your system administrator.
    Thanks
    Praveen
    Edited by: Praveen11 on Jul 7, 2009 7:10 AM

  • User roles property, when system alias is configured in universal worklist

    Hi,
    I am configuring system alias in Universal Worklist Configuration.  I have keyed in system alias and connector type and saved the system alias and its working fine.
    Apart from system alias and connector type, there are other properties like "User Roles, Delta Pull Channel Refresh Period(in seconds) and Delta Pull Channel Snapshot Refresh Period(in minutes). Can you any let me know what is the use of these properties.
    I heard that "Delta Pull Channel Refresh Period(in seconds)"  is the time period to refresh the UWL is it correct.
    Thanks & Regards,
    H.K.Hayath Basha.

    Try searching the http://help.sap.com  SAP NetWeaver pages for delta pull!

  • Running 'netstatt' On An Interface Alias Returns Nothing.

    Hi all,
    can some one please shed some light on this behavior. We defined some network interface aliases on a SunOS machine. Running a 'netstat' on the alias returns nothing, while running it on the actuall device name returns the expected stats.
    Is this behavior by design?
    How can you get stats running this cmd on an alias interface name?
    Thank you

    It did not solve the issue. But I found it.
    I sketch what I've done .. maybe others can use that info too.
    Reason: For traditional reasons, we use Apache Configs for Aliases ... no mapping within CF itself because up to CF9 those mappings are global. Howerver, for UNC mappings, this seems to be the bad way.
    Up to today, I had no idea how Apache and CF talk to each other on paths. Obvioulsy, CF ask Apache for a path resolution, but Apache as a System Service, was not able to verify the accessibility of the UNC path. Therefore, it or CF figured that they use the webroot of this vhost.
    When I ran Apache as Administrator, it could access the UNC and therefore Apache and/or CF returned the correctly expanded path. Of course, we don't run Apache with more rights than the System Service. Resetting Apache to that also returned the wrong UNC expansion.
    So, we now go with Mappings in CF itself. Since CF 10 allows for Per App Mappings, this is no longer a problem.
    Martin

  • Trying to open a task in UWL, system shown an message

    Hi Frineds
    While trying to open a task in UWL, system shown an message
    SSO logon not possible; invalid host name for issuing cookie
    Choose "Logon" to continue A dialog box appears in which you can enter your user and password
    No switch to HTTPS occurred, so it is not secure to send a password
    Plz let me know the reason and how to fix it
    Regards
    Kumar

    SSO logon not possible; invalid host name for issuing cookie
    You can do this
    (1) Set the security trace level in the ticket accepting system
    ======================================================
    1. Call transaction SM50 (process list):
    2. Process -> Trace -> Reset -> Workprocess Files
    3. Key combination: F5 (select all), CTRL-Shift-F7 => Dialog box;
    4. Set trace level=3 and ONLY(!) check the "Security" component;
      If necessary, you must repeat these steps for each server (see
      transaction SM51), unless you can use a specific server for
      reproducing the error (for example, by excluding the load
      distribution).
    (2) Run the webdiagtool as per example 3.
    (3) While the webdiagtool is running, please reproduce a failed attempt
    to the backend
    (4) When the SSO fails, wait a minute and then press return in the
    diagtool console so that the resulting traces are picked up
    Please check the configuration in portal, use fully qualified domain
    name instead of host name.

  • Mail System Error - Returned Mail

    I have set up the Mail with my Pop accounts from the local cable company. I can send and receive all my mail through those email addresses.
    THE PROBLEM is that every mail recipient receives the above message when they send an email to me:
    Mail System Error - Returned Mail
    Reason: 5.1.1 unknown or illegal alias: [email protected]
    (xxxxxxxxx = my account)
    I receive the email, but the sender is concerned that I don't.
    I DO NOT have a mac.com address, nor do I need or want one.
    Can I delete the mac.com address somehow? I did delete the mac.com from my email accounts, but it didn't solve the problem and any time I try to add an account the mac.com address is the default.
    All the people who send my family emails are beginning to get upset -- Please Help!

    Hello au:
    Welcome to Apple discussions.
    If I were you, I would look at the Mail preferences closely. I suspect (although I do not know, as I have never seen anything like you describe before) that there is a setting that is causing the problem.
    Barry
    P.S. Not much help, but the problem is new to me.

  • Problem in creation of system alias for bw system

    Hi,
    I want to create system alias for the bw system
    system admin->sys Config->system landscape->portal content->my own folder
    for this folder i created the system object
    after creation of system object, from property category i select the connector and give the details.
    after that i select the user management and give
    authentication ticket - select
    Logon method- UIDPW
    User Management type- admin,user
    i saved till now
    in the display object i select the system alias
    then that screen displays
    In the system alias screen, i clicked on add button for adding alias then we r getting this message.
    User Mapping Status:  (Not ready for user mapping configuration)
    Please give the solution for solving this problem
    Regards,
    Sid.
    Edited by: sid m on Mar 11, 2008 12:15 PM

    Hi Krishna,
    I checked  the connection settings.
    WAS settings in system object is giving this mistake
    before user mapping it works fine.
    after giving usermapping i ma getting this exception.
    SAP Web AS Connection
      Test Details:
    The test consists of the following steps:
    1. Check the validity of the system ID in the system object
    2. Check whether the system can be retrieved
    3. Check whether a SAP system is defined in the system object
    4. Validate the following parameters: WAS protocol; WAS host name
    5. Check HTTP/S connectivity to the defined backend application
      Results
    1. The system ID is valid
    2. Retrieval of the system was successful
    3. The system object represents an SAP system
    4. The following parameters are valid: Web AS Protocol (http) Web AS Host Name (172.19.18.75)
    5. HTTP/S connection failed
    for testing the connector i am getting this exception
    Test Connection with Connector
      Test Details:
    The test consists of the following steps:
    1. Retrieve the default alias of the system
    2. Check the connection to the backend application using the connector defined in this system object
      Results
    Retrieval of default alias successful
    Connection failed. Make sure user mapping is set correctly and all connection properties are correct.
    Regards,
    Sid.

  • Which system field returns the number of records returned after a select?

    Which system field returns the number of records returned after a select?
    a) sy-index
    b) sy-recno
    c) sy-lncnt
    d) sy-dbcnt
    e) sy-tabix

    Hi,
       SY-DBCNT
    Regards,
    Prashant

  • Different System Alias in one iView

    Hi all,
    I have an ESS/MSS Szenario based on EP7 SP13 and HCM (ECC 6). I have setup the business package and all is working fine. I have setup the different System Aliases like SAP_R3_HumanResources and SAP_R3_HumanResources_Meta etc. and I have a working Single Sign On between my Portal and the HCM system.
    I now face the challenge to change one link within the working time iView to point to a different system than all the others!
    Let me explain: I have a second ERP 6 system that provides for the actual working time Web Dynpro and this Dynpro is not provided by the HCM system. I think I need to change the target for this one Dynpro to point to the ERP instead of the HCM system while all the other links in the working time iView still have to point to the HCM system!
    I have no idea whatsoever, how to do this. I checked the PCD but I can't seem to find the right place where to adapt the System Alias for an iView at all. Can someone point me in the right direction?
    Kind regards,
       Christian

    No you're not
    In fact you lack the System and System alias that point to you're new ERP 6.
    Here a link with a demo that explain how to create the system and define its alias : [demo|https://www.sdn.sap.com/irj/servlet/prt/portal/prtroot/docs/library/uuid/24d8faf9-0701-0010-c99c-aabbdb7e95f4] .
    Informations needed are the same you can find in a saplogon for the system you want to connect to.
    Once you'll have defined system and alias you'll see it in you're listbox!
    Anyway you'll still face the last problem : you can't define multiple system alias for the same iView.
    Hope that helps!!
    Edited by: Seb on Jan 9, 2008 4:34 PM

  • Creation of System Alias between Portal and E Sourcing System

    Hi Team,
    I would like to create a System Alias between SAP Portal 7.4 and E Sourcing System 10.0. I would like to know during the creation of System Object which template i need to take (is it http System or R/3 System using Load Balancing).
    If it is a HTTP System, I am getting  ""Could not find Connector Factory value: null"".
    Could you please help me in knowing what could be the issue.
    Pls. Note: E Sourcing is a Java based SAP System.

    Hi Sankar,
    Please go through the below SAP Note and see if that helps.
    711769 - SSO between SAP Java Software Products
    BR,
    Anurag

  • Connection tab is inactive during the creation of system alias in portal

    When we trying to implement the note 1249323, during the creation of
    system alias in portal (Step B in SRM 7.0), the connection tab is
    inactive to fill the information (EP-PCT-SRM).
    Please can anybody give a solution to this problem so that we can finish our
    implementation of the note.
    Thanks and regards
    Mahesh

    If you are referring to the property "Collection" of the system object - I don't think you can edit it. It is not used at runtime by the applications/iviews.
    That should have been a mistake in the SAP note and you can ignore that property and go ahead with creating your system.
    Thanks,
    Shanti

  • System alias does not work if not the same as logical system name?

    In most of the situations, we define the portal system alias same as the connected R/3 client logical system name.
    I also saw some exceptions that system aliases were defined differently from the connected R/3 client logical systems, and they were tested fine.
    However I forget the way to make that working.
    Could you help me  recall how is that achieved?
    Thanks!

    Hi,
    There is nothing tricky here. Just assign more System Aliases to the system connector !

  • Unable to create system Alias.

    Hi All,
    I Created one system object , but i am not able to create system Alias.While creating system Alias it throws this  error   "  This system object is restricted and u can't create System Alias". Exactly what is the prob?What is the solution?
    Thanks in Advance.

    Hi,
    system object is restricted
    1. Make sure you have required permissions to create the system object. You should use administrator user to create the system.
    2. Check the object properties and permissions.
    Refer following procedure to create the system object and see if you have missed any step.
    http://wiki.sdn.sap.com/wiki/display/EP/11Systems-+Creation
    Regards,
    Varun

Maybe you are looking for

  • Share network traffic between 2 parallel wireless bridges - What kit?

    Dear All, I'm a technology professional, but mainly in electronic design rather than high end networking. Hence my request for your advice. I wish to specify some items of kit that I can ask a networking professional to fit and configure to solve my

  • How to create ALIAS on Macbook Pro? Samples?

    Here are the directions.... The installer creates a sound library folder at "/Library/Application Support/UVISoundBanks/". All sound library must be copied or aliased to this folder so UVI Workstation can access to the contents easily. So, I want to

  • Problem with varargs

    The variable-length parameter must be the last parameter declared by the method...................... Can anyone explain me please, why it will be the last parameter????

  • Labview 8.6.1 - builder message vi is password protected

    I am new in Labview 8.6.1 and I am receiving some messages that I can not explain why. While labview is building an executable I have few messages like the one posted in attachment. The messages are related to the vis that are part of Labview library

  • GRC AC V10 - Mitigation Control Approval Workflow

    Hi guys, can me explain somebody the difference between the processID SAP_GRAC_CONTROL_ASGN und SAP_GRAC_CONTROL_MAINT? And as well can somebody provide me the initiator rule ID for both so that we can have a detailed look into the brfplus rule. We o