Add field RFQ in ALV ME28

Hi all,
I want to add the fiel RFQ in the ALV ME28.
I found a post which says to add a field in ALV, I have to modify the structure MEREP_OUTTAB_PURCHDOC to had an append RFQ"
How shall I do that ?
Thanks all

Try to find any BADI for the same
Follow the below steps to find out what all BADI's are called when you press any button in any transaction.
1) Goto se24 (Display class cl_exithandler)
2) Double click on the method GET_INSTANCE.
3) Put a break point at Line no.25 (CASE sy-subrc).
Now
4) Execute SAP standard transaction
5) Press the required button for which you need to write an exit logic, the execution will stop at the break point.
6) Check the values of variable 'exit_name', it will give you the BADI name called at that time.
7) This way you will find all the BADIs called on click of any button in any transaction.
OR
Also one more option is to copy ME28 and, make modifications to the copied program.

Similar Messages

  • Add field in standard ALV report.

    Hi friends,
    In SAP standard ALV report, t.code- S_ALR_87012050, user wants the vendor to include information about source document - vendor number, vendor name, invoice number, original document number of the transaction in the case of payroll being capitalized.
    I tell me weather this information is already present in the report or I have to create Z report for adding this information and how do I proceed to add new fields in the created Z program.
    Please help me.
    Thanks in advance,
    Saya

    HI Saya,
    Check in the ALV output whether these fields are already there and not displaying in the ALV output, if the fields are not at all printing in the ALV output,then copy the Program to Z program and change it.
    write the Code to add the new fields to the internal table and change the Field catalaog to come your fields in the ALV output then print it
    Regards
    SUdheer

  • How to add field to the header for FBL5N ALV report

    Hi,
       I need to add fields to the customer line item display ALV report(FBL5N) header part.Right now there are four fields in the header like customer, company code, name and city, after that I need to add first name last name and phone no. Can any one tell me where exactly I need to add and populate there fields to be appear in ALV output list.
    Thanks in Advance
    Swapna

    Yes I have tried, I have place a break point in that perform but it does not stop. I think that is not the correct place to added and populate fields. That routine is for populate selection screen ranges single and multiple values and parameters only.
    Thanks
    Swapna

  • Need to Add field EKET-EINDT and EKET-SLFDT to ME2M Report output in ALV

    Hi All,
    I need to add fields EKET-EINDT and EKET-SLFDT to the output of program ME2M Transaction.
    I have appended the structure MEREP_OUTTAB_PURCHDOC with these fields. and it is coming in the ALV output field catalog.
    I need these fields output only for ALV display only.
    Please let me know which enhancement i need to write code to enhance the output with these filed values added to the ALV internal table
    Thanks in Advance
    Arun

    Hi All,
    I am able to get the field EINDT and SLFDT into the structure using Append structure and is also getting displayed in the output in ALV.
    But i need to know how to add code for filling these fields and passing into ALV. I need to know the Enhancement spot.
    Please let me know how to achieve this scenario
    Thanks
    Arun

  • Add New Column in ALV Report of Standard SAP ME28.

    Hi anybody,
    I want add new column in alv report of standard SAP Program ME28 Screen.
    Add Last PO Price column inside ALV Report ME28 Screen.
    Can u please anybody tell me how to add new column in ME28 Screen.
    Thanks
    S.Muthu.

    Try to find any BADI for the same
    Follow the below steps to find out what all BADI's are called when you press any button in any transaction.
    1) Goto se24 (Display class cl_exithandler)
    2) Double click on the method GET_INSTANCE.
    3) Put a break point at Line no.25 (CASE sy-subrc).
    Now
    4) Execute SAP standard transaction
    5) Press the required button for which you need to write an exit logic, the execution will stop at the break point.
    6) Check the values of variable 'exit_name', it will give you the BADI name called at that time.
    7) This way you will find all the BADIs called on click of any button in any transaction.
    OR
    Also one more option is to copy ME28 and, make modifications to the copied program.

  • MR51 : add custom field in the alv list

    Dear.
    I need to add a custom field in the alv layout of MR51.
    Do you know any exit in order to obtain this ?
    Thanks.

    Hi,
    try this
    I think there is no exits for same
    copy program of MR51 and make z one and add filed what filed you want to add
    Regards
    kailas Ugale

  • Field Catalogs in ALV

    Hi Friends,
    Please help me out, I am new to ABAP.
    Please anybody explain me the functionality of Field catalogs in ALVs?
    How many methods are there to pass data to ALVs, i.e., in how many ways?
    Hope u will help me.

    hi,
    this will be very helpful for ALV REPORTING.....
    Sap provides a set of ALV (ABAP LIST VIEWER) function modules which can be put into use to embellish the output of a report. This set of ALV functions is used to enhance the readability and functionality of any report output. Cases arise in sap when the output of a report contains columns extending more than 255 characters in length.  In such cases, this set of ALV functions can help choose selected columns and arrange the different columns from a report output and also save different variants for report display. This is a very efficient tool for dynamically sorting and arranging the columns from a report output. The report output can contain upto 90 columns in the display with the wide array of display options.
    The commonly used ALV functions used for this purpose are;
    1.     REUSE_ALV_VARIANT_DEFAULT_GET
    2.     REUSE_ALV_VARIANT_F4
    3.     REUSE_ALV_VARIANT_EXISTENCE
    4.     REUSE_ALV_EVENTS_GET
    5.     REUSE_ALV_COMMENTARY_WRITE
    6.   REUSE_ALV_FIELDCATALOG_MERGE
    7.   REUSE_ALV_LIST_DISPLAY
    8.     REUSE_ALV_GRID_DISPLAY
    9.     REUSE_ALV_POPUP_TO_SELECT
    The different steps used for getting the above function modules into use are:
    Step 1
    DATA DECLARATION
    Sap standard type pools:  SLIS , KKBLO .
    Sap standard tables types taken from the type pools are:  SLIS_LAYOUT_ALV ,
                                             SLIS_T_FIELDCAT_ALV,
    SLIS_T_LISTHEADER,
    SLIS_T_EVENT,
    SLIS_SELFIELD.
    Internal tables to used in the program declared based on the above table types
    DATA:  I_LAYOUT TYPE SLIS_LAYOUT_ALV,
                I_FIELDTAB TYPE SLIS_T_FIELDCAT_ALV,
               I_HEADING TYPE SLIS_T_LISTHEADER,
    I_EVENTS TYPE SLIS_T_EVENT.
    TYPES:  KKBLO_SELFIELD TYPE SLIS_SELFIELD.
    Step 2 (Optional)
    SELECTING THE VARIANTS FOR INITIAL LIST DISPLAY (DEFAULT VARIANT)
    The variants in the list display can be both user-specific and general. The user can programmatically set the initial (default) variant for list display.
    The default variant can be found using the function module 'REUSE_ALV_VARIANT_DEFAULT_GET'.
    Sample code:
    CALL FUNCTION 'REUSE_ALV_VARIANT_DEFAULT_GET'
           EXPORTING
                i_save     = variant save condition ( A=all, U = user-specific )
           CHANGING
                cs_variant = internal table containing the program name (and the default variant---optional )
           EXCEPTIONS
                not_found  = 2.
    The user can also choose from the list of existing variants using the function module ‘REUSE_ALV_VARIANT_F4’.
    Step 3
    DEFININING OUTPUT CHARACTERISTICS: PREPARING DISPLAY FIELDS CATALOG
    A field catalog is prepared using the internal table (I_FIELDCAT) of type SLIS_T_FIELDCAT_ALV. Field catalog containing descriptions of the list output fields (usually a subset of the internal output table fields).
    A field catalog is required for every ALV list output to add desired functionality (i.e. Key, Hotspot, Specific headings, Justify, Col. position etc) to certain fields of the output. If not mentioned specifically, then the defaults are taken. The possible values and defaults are listed below.
    The field catalog for the output table is built-up in the caller's coding. The build-up can be completely or partially automated by calling the REUSE_ALV_FIELDCATALOG_MERGE module.
    The minimal field catalog is documented below. This can be done in a routine using a local variable. The user can use the other optional parameters to assign output attributes to different fields in the output, which differ from the default.
    A field catalog need not be built-up and passed explicitly only under the following conditions:
    1.     The internal table to be output has the same structure as a Data Dictionary structure which is referred to in the internal table declaration using LIKE or INCLUDE STRUCTURE. In this case the attributes of the different fields is taken directly from the table and the attributes (key fields, length, texts etc) need to state explicitly.
    2.     all fields in this structure are to be output
    3.     The structure name is passed to ALV in the parameter I_STRUCTURE_NAME of the function module REUSE_ALV_LIST_DISPLAY.
    All the values entered in the catalog is specific to the particular field whose name is entered in the fieldname FIELDNAME of the fieldcat structure. The name of the table is also entered in the corr. Fieldname TABNAME of the structure.
    The different possible attributes are:
    •     Row_pos (row position): Only relevant if the list output is to be multi-line (two or three lines) by default. So, this attribute can be used maintain certain level of alignment in the output.
                         Value set: 0, 1 – 3
    •     Col_pos (column position): This parameter is relevant when the fields in the output are to be different from the sequence of the fields in the internal table used for display.       The parameter specifies the relative column position of the field in the list output. The column order can be changed interactively by the user. If this parameter is initial for all field catalog entries, columns appear in the internal table field sequence.
    Value set: 0, 1 – 60
    •     Fieldname (field name): This is the name of the internal table field for which the parameters are passed in the catalog.
    Value set: internal output table field name (required parameter)
    •     Tabname (internal output table): Name of the internal output table that contains the field FIELDCAT-FIELDNAME above.
                         Value set: SPACE, internal output table name.
    •     Ref_fieldname (reference field name): Name of the Data Dictionary field referred to. This parameter is only used when the internal output table field described by the current field catalog entry has a reference to the Data Dictionary (not a program field), and the field name in the internal output table is different from the name of the field in the        Data Dictionary. If the field names are identical, naming the Data Dictionary structure or table in the FIELDCAT-REF_TABNAME parameter is sufficient.
        Value set: SPACE, Data Dictionary field name.
    •     Ref_tabname (reference table/structure field name): Structure or table name of the referred Data Dictionary field.        This parameter is only used when the internal output table field described by the current field catalog entry has a Data Dictionary reference (not a program field).
    Value set: SPACE, name of a Data Dictionary structure or table
    Link to currency unit
    •     Cfieldname (currency unit field name): This is used for currency fields that have a reference to any unit field. This is only relevant for amount columns with associated unit. This parameter contains the Name of the internal output table field containing the currency unit associated with the amount field FIELDCAT-FIELDNAME. The field in FIELDCAT-CFIELDNAME must have its own field catalog entry.
    Value set: SPACE, output table field name
    •     Ctabname (internal currency unit field output table): Name of the internal output table containing the FIELDCAT-CFIELDNAME field.
    Value set: SPACE, output table field name.
            Link to measurement unit
    •     Qfieldname (measurement unit field name): Only relevant for quantity columns with unit link. Name of the internal output table field containing the measurement unit associated with the quantity field FIELDCAT-FIELDNAME. The field in FIELDCAT-QFIELDNAME must have its own field catalog entry.
    Value set: SPACE, output table field name.
    •     Qtabname (internal measurement unit field output table): Name of the internal output table containing the FIELDCAT-QFIELDNAME field.
    Value set: SPACE, output table field name.
    •     Outputlen (column width): This parameter is used if the desired output length for a field is desired to be different from the internal output table field. For fields with a Data Dictionary link this parameter can be left initial. For fields without a Data Dictionary link (program field) the parameter must be given the value of the desired field list output length (column width).
    Initial = column width is the output length of the referred Data Dictionary field (domain).
    N = column width is n characters.
          Value set: 0 (initial), n.
    •     Key (key column): By default, the system makes some fields in the output as key fields, provided the fields are key fields in their referencing table. Using this parameter, fields other than key fields of the referencing table can be made key field. This parameter is most important if the output needs to contain some field which are not scrollable or cannot be hidden.
    If the internal output table contains fields that are key fields from different tables, then all those fields in the report output becomes unscrollable and cannot be hidden. So, the fields in the output internal table should not be referenced from tables in which they are key fields. Instead, they should be referenced to the tables in which they are not key fields, incase they are not desired as key field in the output.
    'X' = key field (key field output in color) and Key fields can not be interactively hidden. Parameter FIELDCAT-NO_OUT must be left initial.
          Value set: SPACE, 'X'.
    •     Key_sel (hideable key column): This parameter is only relevant for the fields which are made key fields using FIELDCAT-KEY = 'X'. Using this parameter the Key field can be hidden interactively.
    The key column sequence cannot be changed interactively by the user. The output is controlled by the FIELDCAT-NO_OUT parameter analogously to non-key fields.
    Value set: SPACE, 'X'.
    •     No_out (field in field list): This parameter is used to remove certain fields from the output during initial display.  The user can however interactively choose the field for output from the field list in the display variant.
                'X' = field is not displayed in the current list.
            Value set: SPACE, 'X'.
    •     Tech (technical field): This parameter is used to make certain field display only in the field catalog. The fields with this parameter set cannot be output in the list nor can they be displayed interactively from the catalog.
                        'X' = technical field.
           Value set: SPACE, 'X'.
    •     Emphasize (highlight columns in color): As name suggests, this field parameter is used to highlight certain field with chosen colors.
    Value set: SPACE, 'X' or 'Cxyz' (x:'1'-'9'; y,z: '0'=off ,'1'=on).
    'X' = column is colored with the default column highlight color.
                        'Cxyz' = column is colored with a coded color:
                      -  C: Color (coding must begin with C)
                     -  X: color number
                      -  Y: bold
                       -  Z: inverse
    •     Hotspot (column as hotspot): This parameter is used to make certain field appear as hotspot i.e. a hand is displayed if the cursor is positioned on the field value. Single click on such fields cause the PICK OR F2 events to happen.
             Value set: SPACE, 'X'.
                        'X' = column cells are output as hotspots.
    •     Fix_column (fix column): This parameter is used to fix certain columns in the output. All columns to be fixed must have this flag, starting from the left. If a column without this flag is output, only the columns to the left of this column are fixed. The user can change the column fixing interactively.
                         Value set: SPACE, 'X'.
            'X' = column fixed (does not scroll horizontally).
    •     Do_sum (sum over column): the user can also call this function interactively.
                      Value set: SPACE, 'X'.
    'X' = a sum is calculated over this internal output table field.
    •     No_sum (sums forbidden): No sum can be calculated over this field, although the data type of the field would allow summing.
             Value set: SPACE, 'X'.
    •     Icon: The parameter displays certain column contents as icons. The internal output table column contents must be valid icon strings.
                        Value set: SPACE, 'X'.
                         'X' = column contents to be output as an icon.
    •     Symbol: The internal output table column must be a valid symbol character.
    Value set: SPACE, 'X'
                        'X' = column contents are to be output as a symbol.
    •     Just (justification): This parameter is used for alignment of the contents of the output table. This is only relevant for CHAR or NUMC fields in the output internal table. The justification of the column header always follows the justification of the columns. Independent justification of the column header is not possible.
    Value set: SPACE, 'R', 'L', and ‘C’.
           ' ' = Default justification for this data type
           'R' = right-justified output
           'L' = left-justified output
           'C' = centered output.
    •     Lzero (leading zeros): By default ALV outputs NUMC fields right-justified without leading zeros. Using this parameter only the NUMC fields can be displayed with leading zeroes.
                       Value set: SPACE, 'X'.
                        'X' = output with leading zeros.
    •     No_sign (no +/- sign): This parameter is used to suppress the signs of the output fields. It is only relevant for the value fields.
        Value set: SPACE, 'X'.
               'X' = value output without +/ sign.
    •     No_zero (suppress zeros): Only relevant for value fields.
                 Value set: SPACE, 'X'.
                        'X' = suppress zeros.
    •     Edit_mask (field formatting): To apply the report output formatting options same as in the WRITE statement in report writing.
               Value set: SPACE, template.
    The following parameters are used for customizing the texts in the heading of the output of the columns. The texts are taken from the Data Dictionary for fields with a Data Dictionary reference. If this is not desired, the text parameters can also be specified. The Data Dictionary texts are then ignored.
    If the user changes the column width interactively, the column header text with the appropriate length is always used.
    The interactive function 'Optimize column width' takes account of both the field contents and the column headers: if all field contents are shorter than the shortest column header, the column width depends on the column header.
         The 'long field label' is also used in display variant definition,
            Sort, etc.  Popup.
    •     seltext_l (long field label)
    •     seltext_m (medium field label)
    •     seltext_s (short field label)
    •     reptext_ddic(header) Analogous to the Data element main header
    •     Ddictxt (specify text) : You can specify with values 'L', 'M',  and 'S', the keyword that should always be used as column header. If the column width changes, no attempt is made in this case to find an appropriate header for the new output width.
    Value set: SPACE, 'L', 'M', and ‘S’.
    Sample code:
    Suppose I_PO_DETAILS is an internal table containing two fields EBELN (PO number) and EBELP (PO item no).
    DATA: L_FIELDCAT TYPE SLIS_FIELDCAT_ALV.     “Local variable to hold the parameters                                                                               
    for a particular field of the field catalog
      CLEAR L_FIELDCAT.
      L_FIELDCAT-TABNAME   = 'I_PO_DETAILS'.
      L_FIELDCAT-FIELDNAME = 'EBELN'.
      L_FIELDCAT-KEY = 'X'.         “The PO no is made the key field,
                          “Colored and non scrollable
      L_FIELDCAT-HOTSPOT = 'X'.     “The po no becomes a hotspot
      L_FIELDCAT-SELTEXT_S = ‘P.O No’.
      L_FIELDCAT-SELTEXT_M = 'P order No'.
      L_FIELDCAT-SELTEXT_L = 'Purchase order No'.
      APPEND L_FIELDCAT TO I_FIELDTAB.
      CLEAR L_FIELDCAT
      L_FIELDCAT-TABNAME   = 'I_PO_DETAILS'.
      L_FIELDCAT-FIELDNAME = 'EBELN'.
      L_FIELDCAT-KEY = 'X'.         “The po item no is made the key field,
                               “Colored and non scrollable
      L_FIELDCAT-SELTEXT_S = 'Item No'.
      L_FIELDCAT-SELTEXT_M = 'Item No`.
      L_FIELDCAT-SELTEXT_L = 'PO Item No'.
      APPEND L_FIELDCAT TO I_FIELDTAB.
      CLEAR L_FIELDCAT
    Thus the catalog for the report output is prepared.
    Step 4
    The next step is to build an event table, which are used for firing both user commands and the system dependent events i.e. top of page, end of page etc.
    A list of possible events is populated into an event table (I_EVENTS) when this table is passed to the function module REUSE_ALV_EVENT_NAMES_GET. The return table from this function module contains all the possible events.
    The function module contains following import and export parameters.
    IMPORTING PARAMETERS: I_LIST_TYPE
    This parameter has possible values from 0-4.
    The parameter I_LIST_TYPE is of TYPE SLIS_LIST_TYPE and is DEFAULT 0 .
    EXPORTING PARAMETERS:  I_EVENTS table.
    This table is of TYPE SLIS_T_EVENT and returns to the program the name of all the possible events.
    The table structure contains the fields:
         I_EVENTS-NAME: Name of the Callback event.
    I_EVENTS-FORM: Name of the form routine that should be called in the calling program at the event.
    Only events with a form routine name are processed.
    The I_EVENTS table returns with the following possible constants:
    1.     Slis_ev_item_data_expand TYPE slis_formname VALUE 'ITEM_DATA_EXPAND'.     
    Only relevant for hierarchical-sequential lists using the layout parameter IS_LAYOUT-EXPAND_FIELDNAME of the structure IS_LAYOUT. Exit for passing item entries (ITEM table) for a header record that was expanded interactively by the user.
    2.     Slis_ev_reprep_sel_modify TYPE slis_formname VALUE 'REPREP_SEL_MODIFY'.
    RS_SELFIELD-TABINDEX contains the header table index for which the item entries are to       be put in the global item output table (T_OUTTAB_SLAVE). The Callback is only called if ALV has no items for a header that is to be expanded.
    RFLG_ALL is passed with 'X' if the user shows all items. The application must ensure that    entries are not repeated in the item table.
        RS_SELFIELD is initial in this case.         
    3.     Slis_ev_caller_exit_at_start TYPE slis_formname VALUE 'CALLER_EXIT'.
    Is called at the beginning of the function module to make special settings. It is not usually used.          
    4.     Slis_ev_user_command TYPE slis_formname VALUE 'USER_COMMAND'.
    As this is a frequently-used Callback event, the form routine can also be passed        directly in the interface by passing the user command in the IMPORTING parameter           I_CALLBACK_USER_COMMAND.
    5.     Slis_ev_top_of_page TYPE slis_formname VALUE 'TOP_OF_PAGE'.
       Equivalent to the list processing TOP-OF-PAGE event.           
    6.     Slis_ev_top_of_coverpage TYPE slis_formname VALUE 'TOP_OF_COVERPAGE'.       
    The selection information and list status are output together (if they exist) on a separate page by default
    7.     Slis_ev_end_of_coverpage TYPE slis_formname VALUE 'END_OF_COVERPAGE'.       
    Analogously to TOP_OF_COVERPAGE the user can add other information
    to the information output by ALV (selection information, list status) at this event.
    8.     Slis_ev_foreign_top_of_page TYPE slis_formname VALUE ‘FOREIGN_TOP_OF_PAGE'.
    The Top-of-page event is always processed in ALV and is only passed to the caller via the Callback mechanism. This is still the case if the caller, e.g. by a user action, processes a branch list which was not formatted by ALV (e.g. a popup with additional information about the list record selected and displayed by ALV).
    In this case, top-of-page cannot be formatted by ALV analogously to the basic list, it must be handled completely by the caller. The event top-of-page still occurs in ALV. When ALV notices a top-of-page which was not caused by an ALV output, the form routine in FOREIGN_TOP_OF_PAGE is called.
    9.     Slis_ev_foreign_end_of_page TYPE slis_formname VALUE 'FOREIGN_END_OF_PAGE'.  
    The event end-of-page is always processed in ALV and only passed to the caller via callback. This is still the case, e.g. when the caller processes a details list which was not formatted by ALV (e.g. a popup with further information about selected list records which were displayed by ALV).
    In this case, end-of-page cannot be formatted by ALV analogously to the basic list, it must be handled completely by the caller. The event end-of-page still occurs in ALV. When ALV notices an end-of-page that was not caused by an ALV output, the form routine in FOREIGN_END_OF_PAGE is called.                             
    10.     Slis_ev_pf_status_set TYPE slis_formname VALUE 'PF_STATUS_SET'.
    If a user list status is to be set, it must be done in the form routine assigned to this event. The ALV function codes, which must not be active, are in the Parameter RT_EXTAB. This table must be passed with the SET PF-STATUS command (with inactive user function codes as well, if necessary).
    The STANDARD status of the function group SALV should be used as a          template for a user-specific status. As this is a frequently used Callback event, its form routine can also be passed directly in the interface in the IMPORTING parameter I_CALLBACK_PF_STATUS_SET.
    11.     Slis_ev_list_modify TYPE slis_formname VALUE 'LIST_MODIFY'.     
    LIST_MODIFY USING R_TABNAME TYPE SLIS_TABNAME
                                             R_INDEX LIKE SY-TABIX
                                             R_INDEX_ITEM LIKE SY-TABIX
                                             R_INDEX_SUM LIKE SY-TABIX.
    12.     Slis_ev_top_of_list TYPE slis_formname VALUE 'TOP_OF_LIST'.  
    Information output at the start of the list     
    13.     Slis_ev_end_of_page TYPE slis_formname VALUE 'END_OF_PAGE'.
    Information output at the end of a page. This is only called for printing.
    14.     Slis_ev_end_of_list TYPE slis_formname VALUE 'END_OF_LIST'.     
    Information output at the end of the list
    15.     Slis_ev_after_line_output TYPE slis_formname VALUE 'AFTER_LINE_OUTPUT'.
    Output information after each output line. Should only be used in justified cases because it costs a lot of performance.
    16.     Slis_ev_before_line_output TYPE slis_formname VALUE   'BEFORE_LINE_OUTPUT'.       
    Output information before each output line. Should only be used in justified cases because it costs a lot of performance.         
    17.     Slis_ev_subtotal_text TYPE slis_formname VALUE  'SUBTOTAL_TEXT'.                        
    This event table (I_EVENTS) is now checked with the desired constants. If the desired constant is found, then the corresponding field for the FORM NAME is populated with the name of the routine containing the corresponding event.
    Sample code :
    FORMNAME_TOP_OF_PAGE TYPE SLIS_FORMNAME VALUE 'TOP_OF_PAGE',
    FORMNAME_END_OF_PAGE TYPE SLIS_FORMNAME VALUE 'END_OF_PAGE', FORMNAME_USER_COMMAND TYPE SLIS_FORMNAME VALUE 'USER_COMMAND'.
    DATA: L_I_EVENT TYPE SLIS_ALV_EVENT.
      CALL FUNCTION 'REUSE_ALV_EVENTS_GET'
           EXPORTING
               I_LIST_TYPE = 0
           IMPORTING
                ET_EVENTS   = I_EVENTS.
      READ TABLE I_EVENTS WITH KEY NAME = SLIS_EV_TOP_OF_PAGE
                               INTO L_I_EVENT.
      IF SY-SUBRC = 0.
        MOVE FORMNAME_TOP_OF_PAGE TO L_I_EVENT-FORM.
        APPEND L_I_EVENT TO I_EVENTS.
      ENDIF.
      READ TABLE I_EVENTS WITH KEY NAME = SLIS_EV_END_OF_PAGE
                               INTO L_I_EVENT.
      IF SY-SUBRC = 0.
        MOVE FORMNAME_END_OF_PAGE TO L_I_EVENT-FORM.
        APPEND L_I_EVENT TO I_EVENTS.
      ENDIF.
      CLEAR L_I_EVENT.
      READ TABLE I_EVENTS WITH KEY NAME = SLIS_EV_USER_COMMAND
                               INTO L_I_EVENT.
      IF SY-SUBRC = 0.
        MOVE FORMNAME_USER_COMMAND TO L_I_EVENT-FORM.
        APPEND L_I_EVENT TO I_EVENTS.
      ENDIF.
    This will prepare the events table for the report.
    The report will contain three forms for the above events:
    1.     FORM TOP_OF_PAGE : This form will contain the top of page event for the report i.e header etc
    Using the function module ‘REUSE_ALV_COMMENTARY_WRITE’, the internal table containing the headings for top of page event can be passed to the list output. Also, any logo specific to the report can be passed to the function module.
    2.     FORM END_OF_PAGE : This form will contain the end of page event for the report i.e footer etc
    3.     FORM USER_COMMAND : This form will contain the desired user command i.e pick/line selection
    Step 5
    A layout is build for the report output list description USING the internal table declared above (I_LAYOUT).
    Output list description structure.
         The parameters are described under the following heads:
    •     Display options
    •     Exceptions
    •     Totals
    •     Interaction
    •     Detail screen
    •     Display variants (only for hierarchical-sequential lists)
    •     Color
    •     Other
    The layout table is of type slis_layout_alv_spec and has the following fields:
    Display options                                                
    1. Colwidth_optimize (1) TYPE c: This parameter optimizes the length of the different columns in the output. The width of the different col. now depends on the max. Length of the data in the column.
    Value set: SPACE, 'X'
    'X' = optimizes the column width so that all contents are displayed completely.                   
    2. No_colhead(1) TYPE c : This parameter suppresses the column headings                    
    Value set: SPACE, 'X'.
    'X' = column headers are not output
    3. No_hotspot(1) TYPE c :  The heading of the report output are not output as hotspot.       
    Value set: SPACE, 'X'.
    'X' = column headers are not output as hotspot
    4. Zebra(1) TYPE c : The report is output in the striped pattern.             
    Value set: SPACE, 'X'.
    'X' = striped pattern (e.g. for wide lists)
    5. No_vline(1) TYPE c : The report output contains columns only separated by space and no lines.  It is not relevant for: hierarchical-sequential lists and multiple-line lists.
    Value set: SPACE, 'X'.
    'X' = columns separated by SPACE
    6. No_min_linesize(1) TYPE c : The report  line size is equal to the width of the list. It is not relevant for block lists.
    Value set: SPACE, 'X’.
    'X' = line size depends on list width
    '  ' = Line size is set to 80 or MIN_LINESIZE (if > 0) .
    7. Min_linesize LIKE sy-linsz: The report output contains a minimum possible length of line. If initial min_linesize is set to 80 by default, then this parameter is used to customize it. The prerequisite for this is that the parameter no_min_linesize should be ' '.
    Value set: 0, 10 - 250
    If the list is wider, the format uses the list width (maximum 250 or MAX_LINESIZE (if > 0)).
    8. Max_linesize LIKE sy-linsz: The default max. Linesize is 250. To change this default value, this parameter can interactively-define the maximum list width setting.
    Value set: 0, 80 - 1020
    9. Window_titlebar LIKE rsmpe-tittext: To set the titlebar on the report output.                            
               10. No_uline_hs(1) TYPE c.
    Exceptions                                                 
    11. Lights_fieldname TYPE slis_fieldname: Internal output table field containing the codes of exceptions to be output.
                      Output table field code:  '1' = red traffic light
                                    '2' = yellow traffic light
                                         '3' = green traffic light Fieldname for exception 
         Value set: SPACE, internal output table field name.
    12. Lights_tabname TYPE slis_tabname: Name of the internal output table that contains the field in the parameter LIGHTS_FIELDNAME. If LIGHTS_FIELDNAME is not empty, this field must also be filled for hierarchical-sequential lists. Only relevant for hierarchical-sequential lists.
    .     Value set: SPACE, internal output table name.
    13. Lights_rollname LIKE dfies-rollname: The documentation of this data element is displayed when you call F1 help for an exception column.
    Value set: SPACE, data element name.
               14. Lights_condense(1) TYPE c : If a list record is output with 'red traffic light', each
               Subtotal that includes this record is also output with 'red traffic light'.
               Value set: SPACE, 'X'
               'X' = the 'maximum' exception of the items in the subtotal is output at subtotal level.
    Sums                                                       
    15. No_sumchoice(1) TYPE c : This parameter allows the choice for summing up
    Only by fieldcatalog.
    Value set: SPACE, 'X'
    'X' = fields which are to be summed, passed by the calling program (FIELDCAT-DO_SUM = 'X'). The user should not be able to change this value interactively.
    16. No_totalline(1) TYPE c : Removes the option of having totals after sub-totals.
    Value set: SPACE, 'X'
    'X' = no total record is to be output. Subtotals can still be calculated and output. The fields in the subtotals are flagged DO_SUM = 'X' in the field list.
    17. No_subchoice(1) TYPE c : Does not allow the user to interactively change the field chosen for subtotals.
    Value set: SPACE, 'X'
    'X' = value whose change triggers subtotals, provided by the calling program. The user should not be able to change this value interactively.
    18. No_subtotals(1) TYPE c : No subtotals possible          
    Value set: SPACE, 'X'
    'X' = no subtotals.
    19. Numc_sum(1)  TYPE c : Totals only possible for NUMC-Fields.
    20. No_unit_splitting TYPE c: No separate total lines by inh.units   
    21.totals_before_items TYPE c: Display totals before the items   
    22. Totals_only(1) TYPE c :  Show only totals      
    Value set: SPACE, 'X'
    'X' = only total records are output.
    23. Totals_text(60) TYPE c : Text for 1st col. in totals   
    Value set: SPACE, string (max.60)
    ' ' = The first column in the total record contains an appropriate number of '*'s to indicate the total by default. If the first column is wide enough, the string 'Total' is output after the asterisks.
    'String’ = The string passed is output after the total indicated by '*', if the column is wide enough.
    24. Subtotals_text(60) TYPE c : Texts for subtotals
    Value set: SPACE, string (max.60)
    ' ' = In the first column of subtotal records, the subtotal is indicated by an appropriate number of '*' by default. If the first column is not a subtotal criterion, the string 'Total' is output after the asterisks, if the column is wide enough.
    'String’ = the string passed is output after the subtotal indicated by '*', if the column is wide enough and the first column is not a subtotal criterion. If it is a subtotal criterion, its value is repeated after the total, if the column is wide enough.
    Interaction                                                      
    25. Box_fieldname TYPE slis_fieldname: Fieldname for checkbox in the report output. If the list has checkboxes at the start of records (for selecting several records), this parameter contains the internal output table field name indicated by the checkbox selection column. The field is a checkbox at the start of list records without a list header.
    Value set: SPACE, internal output table field name
    26. Box_tabname TYPE slis_tabname: Name of the internal output table that contains the field in the parameter BOX_FIELDNAME. If BOX_FIELDNAME is not empty, this field must also be filled for hierarchical-sequential lists.
    Value set: SPACE, internal output table name.
    27. Box_rollname LIKE dd03p-rollname: rollname for checkbox          
    28. Expand_fieldname TYPE slis_fieldname: fieldname flag ‘expand’. The user can show or hide the items by clicking on the folder symbol (hotspot). If the items for a header entry are only to be read by the calling program and passed to ALV when a header has been expanded interactively, this can be controlled via the CALLBACK event        'ITEM_DATA_EXPAND'.
    29. Hotspot_fieldname TYPE slis_fieldname: Used to make the fieldname flag hotspot.
    30. No_input(1) TYPE c : The fields are only display fields.
            Value set: SPACE, 'X'
    'X' = all ready-for-input fields in a list are displayed as not ready-for-input. (Record selection checkboxes and fields which can be made ready-for-input via the field list parameter FIELDCAT-INPUT = 'X')
    31. F2code LIKE sy-ucomm: To assign an ALV standard function code to double-click (F2), assign the function code to this parameter. Ex.: to assign the ALV standard function 'Detail' ('&ETA') to F2.
                      => LAYOUT-F2CODE = '&ETA'.
    Value set: SPACE, function code
    32. Confirmation_prompt: confirm. Prompt when leaving       
    Value set: SPACE, 'X'
    'X' = if one of the functions ‘Back (F03)', ‘Exit (F15)' or ‘Cancel (F12)' occurs, a confirmation prompt appears.
    33. Key_hotspot(1) TYPE c : The key fields are displayed as hotspot. The columns defined in the field catalog as key fields (FIELDCAT-KEY = 'X') are output as hotspots, i.e. clicking on a key column (highlighted in color in the list) calls the function under F2.
    Value set: SPACE, 'X'.
    34. Reprep(1) TYPE c :  report report interface active.     
    35. Group_buttons(1) TYPE c :  group-buttons for COL1 - COL5 . Group output fields via FIELDCAT-SP_GROUP in the field list, and pass the group name to the list module in the interface parameter IT_SPECIAL_GROUPS.           
    Value set: SPACE, 'X'.
    36. No_keyfix(1) TYPE c : Used to make the key fields scrollable.
    Value set: SPACE, 'X'.
    ' ' = The key columns defined in the field catalog by FIELDCAT-KEY = 'X' are fixed in the list output. These columns do not scroll horizontally. The item table key columns are fixed in hierarchical-sequential lists. The header table key fields are not considered here.
    'X' = key columns not fixed
    37. Get_selinfos(1) TYPE c : To read selection screen.
    Value set: SPACE, 'X'.
    If the calling program is a report with an ABAP/4 selection screen, setting this parameter makes ALV read the selection screen again. If the selections are read successfully, a pushbutton, via which the user can call a popup which lists the report selections in a simple form, becomes active on the results list output by ALV.
    38.     group_change_edit(1) TYPE c :  Settings by user for new group     
    Value set: SPACE, 'X'
    'X' = the user can enter a format option for each sort criterion in the sort/subtotal popup, for the list format when this value changes (e.g. new page or underline).
    39.     No_scrolling(1) TYPE c : Does not allow scrolling of the list to the right.
    Value set: SPACE, 'X'.
    40. Expand_all(1) TYPE c : Expand all positions                   
    Detailed screen                                                    
    40.     Detail_popup(1) TYPE c : show detail in popup.
    Value set: SPACE, 'X'
    '  '  = List record detail display in full-screen mode, with top-of-page.
    'X'  = list record detail display in popup (without top-of-page).
    41. Detail_initial_lines(1) TYPE c : show also initial lines   
    Value set: SPACE, 'X'
    '  ' = Only fields whose contents are not initial are output in the detail view.
    'X' = initial field contents are also output in detail.
    41.     detail_titlebar(30) type c : Titlebar for detail screen
    Value set: SPACE, string (max.30)
    ` ' = ' Detail: Display' is output as the title of the detail window.
                  'String’ = the string passed is output as the title of the detail window. 
    Display variants                                                   
    42. Header_text (20) TYPE c: Text for header button. Only relevant for hierarchical-sequential lists. You can toggle between display field and field list views via pushbuttons in the display variant definition popup for hierarchical-sequential lists. The views refer to the hierarchy level of the fields. This is technically a toggle between the header table and item table fields.   
    Value set: SPACE, CHAR (20)
    ' ' = The header table field pushbutton text is 'Header' by default.
    CHAR (20) = header table field pushbutton text.
    43.item_text(20) TYPE c : Text for item button. Only relevant for hierarchical-sequential lists. You can toggle the view between the display fields and the field list via pushbuttons in the display variant definition popup for hierarchical-sequential lists. The views refer to the hierarchy level of the fields. This is technically a toggle between the header table and item table fields.        
    Value set: SPACE, CHAR (20)
    ' ' = The pushbutton text for the item table fields is 'Item' by default.
    CHAR (20) = item table field pushbutton text.
    44.default_ item(1) TYPE c : Items as default. Only relevant for hierarchical-sequential lists.
         Value set: SPACE, 'X'
    ' ' = The header table fields are displayed by default in the display variant definition popup. The user can switch to the item table fields interactively.
    'X' = the item table fields are displayed by default in the display variant Definition Popup.    The user can switch to the header table fields interactively.
    Colour                                                       
    45. Info_fieldname TYPE slis_fieldname: infofield for listoutput. A whole list record can be colored individually using a color code in a column of the internal output table for the record. Assign the name of the field containing the color code to this parameter.
    Value set: SPACE, internal output table field name
    The internal output table field must be of type CHAR(3).
    The code must have the following syntax:  'Cxy':
            C = color (all codes must start with 'C')
            X = color number ('1'-'9')
            Y = bold ('0' = off, '1' = on)
    46. Coltab_fieldname TYPE slis_fieldname: Cells can be colored individually using a color code which is contained in a column of the internal output table for the record containing the cell. Assign the name of the field to this parameter.       
    Others                                                
    47. List_append(1) TYPE c :  no call screen. It is only useful to output block-lists without specifying the above modules if the number of list blocks exceeds, or may exceed, the maximum number specified in the block module documentation. These operations are not possible for user-defined block lists.
    Example code :
           I_LAYOUT-f2code       = ws_fcode.
           I_LAYOUT-zebra        = 'X'.
    I_LAYOUT-colwidth_optimize = 'X'.
    I_LAYOUT-no_keyfix = 'X'.
    I_LAYOUT-get_selinfos = 'X'.
    I_LAYOUT-no_hotspot = 'X'.
           I_LAYOUT-no_input = 'X'.
    I_LAYOUT-hotspot_fieldname = FIELDNAME.
    I_LAYOUT-no_input          = ‘X’.
    I_LAYOUT-no_vline          = `X’.
    I_LAYOUT-no_colhead        = ‘ ‘.
    I_LAYOUT-lights_condense   = ` `.
    I_LAYOUT-totals_text       = ` `.
    I_LAYOUT-subtotals_text    = ` `.
    I_LAYOUT-totals_only       = ` `.
    I_LAYOUT-key_hotspot       = ‘X’.
    I_LAYOUT-detail_popup      = ‘X’.
    I_LAYOUT-group_change_edit = ‘X’.
    I_LAYOUT-GROUP_BUTTONS     = ‘X’.
    Step 6
    This step is required to get the selection screen information in the report output.
    The prerequisite for this is to set the parameter LAYOUT-GET_SELINFOS of the IMPORTING structure.
    The parameters to be passed in the IS_SEL_HIDE table are:
    o mode:              'R' = only the entries passed in the internal table IS_SEL_HIDE-T_ENTRIES       
    Are output in the pop up. Selection info, which the list tool read in the selection screen (when called by a report with a selection screen), is replaced by the values passed.
    'S' = the selection info which the list tool read in the selection screen of the calling report are modified by the entries in the table IS_SEL_HIDE-T_ENTRIES.
    o t_entries:         Selection info table
    o t_entries-mode:   'A' = output the selection info for the current table record in the info popup.
    'D' = do not output select option or SELNAME parameter selection info in   the popup.
    o t_entries-selname: (only used in t_entries-mode = 'D') : Name of the select option or parameter.
    The following table fields are only used in t_entries-mode = 'A'. They contain the selection information to be added.
    •     t_entries-field:  DDIC field name of the field for which selection information is to be output.
    •     t_entries-table:  DDIC table names of t_entries-field.
    •     t_entries-stext:  Field name in info popup.
    •     If t_entries-field and t_entries-table have been entered, this text is taken from DDIC.
    •     t_entries-valuf:  Selection condition 'from' value (external format)
    •     t_entries-valut:  Selection condition 'to' value (external format)
    •     t_entries-sign0:  (I)nclusive (E)xclusive
    •     t_entries-option:  All values of the select options Option field allowed.
    Step 6
    The Table IT_SORT is populated with the sort criteria for the different fields.
    The caller specifies the sorting and/or subtotaling of the basic list in the internal table IT_SORT.
    This internal table has the following fields:
         o spos :  Sort sequence
         o fieldname :  Internal output table field name
         o tabname : Only relevant for hierarchical-sequential lists. Name of the internal output table.
         o up : 'X' = sort in ascending order
         o down : 'X' = sort in descending order
         o subtot : 'X' = subtotal at group value change
         o group : '* ' = new page at group value change ,'UL' = underline at group value change
                             Step 7
    The final step in the output of the report is the use of two ALV functions modules.
    1.     REUSE_ALV_FIELDCATALOG_MERGE
    2.     REUSE_ALV_LIST_DISPLAY
    The first function module is used to pass the field catalog to the report output and merge it with the internal output table.
    FUNCTION reuse_alv_fieldcatalog_merge.                                
    ""Lokale Schnittstelle:                                             
    *” IMPORTING                                                    
    *"             VALUE(I_PROGRAM_NAME) LIKE  SY-REPID OPTIONAL          
    *"             VALUE(I_INTERNAL_TABNAME) TYPE  SLIS_TABNAME OPTIONAL  
    *"             VALUE(I_STRUCTURE_NAME) LIKE  DD02L-TABNAME OPTIONAL   
    *"             VALUE(I_CLIENT_NEVER_DISPLAY) TYPE  SLIS_CHAR_1        
    *"                             DEFAULT 'X'                            
    *"             VALUE(I_INCLNAME) LIKE  TRDIR-NAME OPTIONAL            
    *"       CHANGING                                                     
    *"             VALUE(CT_FIELDCAT) TYPE  SLIS_T_FIELDCAT_ALV           
    *"       EXCEPTIONS                                                   
    *"              INCONSISTENT_INTERFACE                                
    *"              PROGRAM_ERROR                                         
    Import parameters 
    I_PROGRAM_NAME: Program in which the internal output table is declared and populated   
    I_INTERNAL_TABNAME: Internal output table name
    I_STRUCTURE_NAME: Structure name (structure, table, and view)
    I_CLIENT_NEVER_DISPL: Hide client fields default ‘X’
    I_INCLNAME: Data declarations include name
    CHANGING parameter
    CT_FIELDCAT: Field catalog with field descriptions
    The variant based on a program-internal table should only be used for rapid prototyping since the following restrictions apply:                                                                               
    1.   Performance is affected since the code of the table definition must always be read and interpreted at runtime.                                                                               
    2.   Dictionary reference are only considered if the keywords LIKE or  INCLUDE STRUCTURE (not TYPE) are used.
    Step 8
    The other function module is used to display the internal output table with the contents
    FUNCTION reuse_alv_list_display.                                          
    ""Lokale Schnittstelle:                                                 
    *” IMPORTING                                                        
    *"             VALUE(I_INTERFACE_CHECK) DEFAULT SPACE                     
    *"             VALUE(I_CALLBACK_PROGRAM) LIKE  SY-REPID DEFAULT SPACE     
    *"             VALUE(I_CALLBACK_PF_STATUS_SET) TYPE  SLIS_FORMNAME        
    *"                             DEFAULT SPACE                              
    *"             VALUE(I_CALLBACK_USER_COMMAND) TYPE  SLIS_FORMNAME         
    *"                             DEFAULT SPACE                              
    *"             VALUE(I_STRUCTURE_NAME) LIKE  DD02L-TABNAME OPTIONAL       
    *"             VALUE(IS_LAYOUT) TYPE  SLIS_LAYOUT_ALV OPTIONAL            
    *"             VALUE(IT_FIELDCAT) TYPE  SLIS_T_FIELDCAT_ALV OPTIONAL      
    *"             VALUE(IT_EXCLUDING) TYPE  SLIS_T_EXTAB OPTIONAL            
    *"             VALUE(IT_SPECIAL_GROUPS) TYPE  SLIS_T_SP_GROUP_ALV         
    *"                             OPTIONAL                                   
    *"             VALUE(IT_SORT) TYPE  SLIS_T_SORTINFO_ALV OPTIONAL          
    *"             VALUE(IT_FILTER) TYPE  SLIS_T_FILTER_ALV OPTIONAL          
    *"             VALUE(IS_SEL_HIDE) TYPE  SLIS_SEL_HIDE_ALV OPTIONAL        
    *"           VALUE(I_DEFAULT) DEFAULT 'X'
    "             VALUE(I_SAVE) DEFAULT SPACE                             
    "             VALUE(IS_VARIANT) LIKE  DISVARIANT                      
    "                             STRUCTURE  DISVARIANT DEFAULT SPACE     
    "             VALUE(IT_EVENTS) TYPE  SLIS_T_EVENT OPTIONAL            
    "             VALUE(IT_EVENT_EXIT) TYPE  SLIS_T_EVENT_EXIT OPTIONAL   
    "             VALUE(IS_PRINT) TYPE  SLIS_PRINT_ALV OPTIONAL           
    "             VALUE(IS_REPREP_ID) TYPE  SLIS_REPREP_ID OPTIONAL       
    "             VALUE(I_SCREEN_START_COLUMN) DEFAULT 0                  
    "             VALUE(I_SCREEN_START_LINE) DEFAULT 0                    
    "             VALUE(I_SCREEN_END_COLUMN) DEFAULT 0                    
    "             VALUE(I_SCREEN_END_LINE) DEFAULT 0                      
    "       EXPORTING                                                     
    "             VALUE(E_EXIT_CAUSED_BY_CALLER)                          
    "             VALUE(ES_EXIT_CAUSED_BY_USER) TYPE  SLIS_EXIT_BY_USER   
    "       TABLES                                                        
    "              T_OUTTAB                                               
    "       EXCEPTIONS                                                    
    "              PROGRAM_ERROR
    Import parameters
    I_INTERFACE_CHECK: Interface consistency check log output.
    I_CALLBACK_PROGRAM: Name of the calling program
    I_CALLBACK_PF_STATUS_SET: Set EXIT routine to status.   
    I_CALLBACK_USER_COMMAND: EXIT routine for command handling
    I_STRUCTURE_NAME: Internal output table structure name     
    IS_LAYOUT: List layout specifications 
    IT_FIELDCAT: Field catalog with field descriptions
    IT_EXCLUDING: Table of inactive function codes   
    IT_SPECIAL_GROUPS: Grouping fields for column selection
    IT_SORT: Sort criteria for first list display
    IT_FILTER: Filter criteria for first list output
    IS_SEL_HIDE     : Selection information modification
    I_DEFAULT:      Initial variant active/inactive logic
    I_SAVE: Variants can be saved
    IS_VARIANT     : Variant information
    IT_EVENTS: Table of events to perform  IT_EVENT_EXIT :  Standard fcode exit requests table 
    IS_PRINT: Print information
    IS_REPREP_ID: Initialization keys for Re/Re interface
    I_SCREEN_START_COLUMN: Coordinates for list in dialog box
    I_SCREEN_START_LINE: Coordinates for list in dialog box
    I_SCREEN_END_COLUMN: Coordinates for list in dialog box        
    I_SCREEN_END_LINE: Coordinates f

  • Add Fields in S_ALR_87013570

    Hi All,
    I want to add fields in ALV in transaction S_ALR_87013570.
    The way i find is to copy the program but it seems very complicated because of 2 things:
    First one, there are a lot of programs to copy and if a update comes, the copy will not be updated...
    Second one, the program seems to be "mandant (system)" dependent...
    Sorry, i've checked now and the program is not System dependent... There was an "If sy-mandt <> XXX".
    I copy the first part and when i activate it, if i try tu use it in my "test mandant", an error appears and say "Program could only be used in mandant (system) XXX".
    Could somme one tell me how to use this program in other mandant (system) (i try to transfer it with scc1 but don't work)?
    And is there any other way to add fields in report S_ALR_87013570?
    Thanks
    Luis.
    PS: Please, apologize me for my english i'm a spanish boy who live in french country :o)
    Message was edited by: me :o)
            Luis Loredo

    Hi,
    I follow this good topic, but I have two questions :
    - I created me own Z* from standard 6PP2-001 and I would like add just one column but I can't ... only new section or horizontale page are available. Can you explain, a little more, the differentes steps to create column ?
    - In a second time, I'm looking for fill this new column with my own selection. User Exit with structure append on CCSS, I think is the good solution but ... I don't find place for abap customer ... any ideas ?
    By advance, Thank you.
    Ps: sorry for my english ...
    Edited by: AlexDoy on Jul 13, 2011 8:36 AM

  • Add fields in VL10 report - EHN

    Hi ,
    I am supposed to add two fields from Table KNVV-KVGR1/KVGR2 table in to alv report output of VL10/VL10A.
    I have tried for BADI but none got trigged. Is.Is the any Badi/Exits available or do I need to go for explict/implicit enhancement.
    Kindly help urgent requirement.
    Thanks in advance.
    Thanks,
    D.Dutta.

    Hi
    Madhu is right. Please, see the coding in include V50R_USEREXITS
    * 1. Add field to list-display
    * Userexits for additional fields on list display
    * use append-structure in DDIC at structure SHP_VL10_ITEM
    * and ad field value in one of these routines
    *INCLUDE LV50R_VIEWG02.       "POS_ITEM_FILL_USER:       SD/MM-orders
    *INCLUDE LV50R_VIEWG03.       "POSTAB_VEPVG_FILL_USER    SD-Index
    *INCLUDE LV50R_VIEWG06.       "POSTAB_VETVG_FILL_USER    MM-Index
    *INCLUDE LV50R_VIEWG07.       "POSTAB_DELIVERY_FILL_USER Delivery item
    Do double click and see the coding. If you are in ECC 6.0, do an implicit. If not, go to SCCR.
    I hope this helps you
    Regards
    Eduardo

  • How to add fields to already loaded cube or dso and how to fill records in

    how to add fields to already loaded cube or dso and how to fill  it.can any one tell me the critical issues in data loading process..?

    This is sensitive task with regards to large volumes of data in infoproviders.
    The issue is to reload of data in case of adjusted structures of infoproviders.
    Indeed there are some tricks. See following:
    http://weblogs.sdn.sap.com/cs/blank/view/wlg/19300
    https://service.sap.com/sap/support/notes/1287382

  • How to ADD field in iview ?

    hi,
    in portal-iview i want to add a field.
    when i go to 'portal-content -> open the iview with right click -> preview' and then
    do ctrl-alt-right-mouse click i got to the customizing of the fields.
    i know how to HIDE fields there, but i don't know how to add fields ? in the list
    of the fields the necessary fields are available, BUT i only have to options:
    hide -> YES or NOT PERSONALIZED
    any ideas ?
    reg, Martin

    Gopal,
    the root element of this fields does NOT have the option 'decorate'.
    it is the quoata overview of ESS : sap.com/ess~quotas
    the top of the tree has option 'decorate', but this is above the necessary table where
    i select the data.
    my adrl is 
    martin.svik(at)denzel.at
    maybe we can 'change' some screenshots where you can send me yours and i can
    send you mine to explain it in a better way
    reg, Martin

  • How to add fields to Structure in Report Painter

    Hi All,
    We have a requiremnt where we need to add 2 fields ( profit center-PRCTR & description-CEPCT-LTEXT ) to structure CCSS. This structure is attached to library 1VK.
    Is it possible to add fields directly to a structure or do I need to create a new structure and attach it to a new library.
    If any one of this is possible, how can I do this ?

    Hi ,
    u can do it in both the ways , but i am not much sure abt second option.
    Useful Tcodes are GR21.
    Regards
    Prabhu

  • How to add fields in a z table

    hi experts !
    i have to add a new fields to an already existing Z table. how can i add field? do i have to delete all other entries and create new ones so that the entry in the new field also gets created.?
    akanksha

    Hi,
    You have two options to enter data type while creating new field in table.
    1. User standard data types i.e. mandt, kunnr etc..to use it u need to press  "Predefined type" button present on top of table fields.
    2. User custom data elements...this data elements you creates when you want to have data field specified to your required length.
    Hope this will help.
    Sumit

  • Add fields to Existing DSO and DS in R/3

    Hi Friends,
    I have got to change my LO datasource which is running on production, 2lis_va_vatim, i need to add 2 fields to the exisitng DS from Comm Stru, so could anyone point me inthe right direction, Hoow to Add the fields with out disturbing the production,
    and the same way i need to cgane my DSO aswell for new fields, please tell me how to meet this.
    Thanks,
    Kiran.

    Hi Kiran,
    Before applying your changes in Production do the below steps:
    1)run V3 job as immediate, which picks data to delta queue and delete the acive V3 job.
    2)run the IP which loads data to BW(Delta IP).
    3)Apply your changes to the 2lis_va_vatim and DSO.
      i)Do the changes(adding your fields to 2lis_va_vatim and DSO)in DEV and active the 2lis_va_vatim and DSO.(insert this in transports).
    ii)first apply the R3 transport and then BW side.
    4)from now on wards your 2 fileds will get populated in BW side.
    5)Maintain the V3 job for 2lis_va_vatim in R3.
    If you need any clarification how to add fields to 2lis_va_vatim and create transport req pelase check the below article.
    http://www.sdn.sap.com/irj/scn/index?rid=/library/uuid/2050db8b-9d90-2c10-2980-b13a4b0938f6
    Hope this helps.
    Regards,
    Venkatesh.

  • Add fields in KOB2 & KSB2 report in selection screen as well as output

    Dear All,
    I have an issue in which i have to add fields in KOB2 & KSB2 report.
    i need to add below fields to KSB2 report.
    1) Internal order
    2) Vendor
    3) Purchasing group
    I also need to add profit centre in selection screen for KSB2
    Similarly for KOB2 i need to add below fields
    1) Cost centre
    2) Vendor
    3) Purchasing group
    I also need to add cost centre as input for KOB2 report.
    I have gone through note 325546 "CO line item reports: Creating a user-defined field" which can be helpful.
    However i am not sure as to how do i add fields in input screen as required.
    Other alternative is to create a Z report however when i try and copy the report both KOB2 & KSB2 call same report "RKAEP000".
    I am not able to get as to how do i differentiate the call of different screens when ZKOB2 is called or when ZKSB2 is called.
    I could identify " c_item_group" field having different values however i couldnot get a proper logic as to how correct screen can be called based on input
    Please suggest .
    Thanks,
    Ronak

    Hi Raymond,
    The note 747588 is good as soon as you are adding fields from the same table only.
    When I have added additional table into KAEP_SCOVP selection view below COVP (just because the extra fields I need are not in COVP) they will show up in KOB1 as selection criteria, but not getting saved.
    Any idea if any ABAP should be regenerated or what extra steps are required when adding more tables into Selection View?
    Thank you!

Maybe you are looking for

  • How do I add a header/footer to a document?

    I am using Adobe X Standard, version 10.1.2 and everything I am reading tells me to go to tools>pages>Header & Footer>Add Header & Footer, but once I click on tools to the left, the only options I have are export and create pdf files and send files.

  • How to get the specific filename

    Hi.. I want to get the specific file where the filename contains current date like "asd.11.20051226.03.dat". Then, i want to write the filename to a text file. Now, i only know how to get the list of file in a specific directory& write the whole list

  • Installing Elements 11 and Premier Elements 11

    I just bought Elements 11 & Premier Elements 11 but cannot install it.  When I click download, I get the Adobe Site Requirements screen, which says I have IE 4 or earlier.  However, I have IE 10.  What do I need to do?

  • Oracle Discoverer Report issue

    One of the report in our setup takes 3 hours on specific day on week , any other day it runs normal. from where to start to diagnose that issue ?

  • Site unreachable via FiOS in MA but reachable via ViOS in MD

    I tried to reach the website istarusa.com from my home in MA and was unsuccessful. I was able to complete a tracert. I later noticed that, when I remoted into a desktop I have in MD which is also on FiOS, it was able to reach istarusa.com. So I check