Adding an app-v package to SCVMM 2012 R2

Hi,
I sequenced an application with App-v Sequencer 5.0 SP1. I don't have an app-v infrastructure (Server, Streaming ...). When the application is sequenced, I have the following files:
Report.xml
Application_Name.appv
Application_Name.msi
Application_Name_DeploymentConfig.xml
Application_Name_UserConfig.xml
I created a folder in my VMM Library with all these files. When a refresh of the library is done, I only have these files:
Report.xml
Application_Name_DeploymentConfig.xml
Application_Name_UserConfig.xml
If I well understand, only .OSD files are supported for App-v packages in VMM library. So I would like to know how to add my app-v package and deploy it from VMM with an application profile please.
Thank you for help.

Hi Hasan,
I haven't seen this issue before, but the following post provides information on checking the registry value:
https://wmoore.wordpress.com/2014/04/11/appcontroller-2012-r2-vmm-registration-error/
The usual caveats about editing the registry apply, including make a backup first.
Regards
Richard
This posting is provided "AS IS" with no warranties, and confers no rights.

Similar Messages

  • Adding a Cluster Hyper-V 2012 into SCVMM 2012 SP1 causes a Crash in VMMService.exe

    I'm trying to register a 5 node Cluster into SCVMM 2012 SP1 host, but when the registration job is running the SCVMMService crashes and then registration becomes inconsistent.
    this is the error log from App Event Viewer:
    Event 1000: Application Error:
    Faulting application name: vmmservice.exe, version: 3.1.6011.0, time stamp: 0x50aaba3f
    Faulting module name: unknown, version: 0.0.0.0, time stamp: 0x00000000
    Exception code: 0xc0000005
    Fault offset: 0x000007fae7615fdb
    Faulting process id: 0x1050
    Faulting application start time: 0x01ce1b77516905f8
    Faulting application path: F:\Program Files\Microsoft System Center 2012\Virtual Machine Manager\Bin\vmmservice.exe
    Faulting module path: unknown
    Report Id: a450c591-876d-11e2-93fe-00155d011c01
    Faulting package full name:
    Faulting package-relative application ID:
    Event 1026: .Net Runtime
    Application: vmmservice.exe
    Framework Version: v4.0.30319
    Description: The process was terminated due to an unhandled exception.
    Exception Info: System.NullReferenceException
    Stack:
       at Microsoft.VirtualManager.Engine.RefreshDriver`1[[System.__Canon, mscorlib, Version=4.0.0.0, Culture=neutral, PublicKeyToken=b77a5c561934e089]].RefreshThreadFunction(System.Object)
       at Microsoft.VirtualManager.Utils.Multithreading.ThrottledThreadPool+<>c__DisplayClass3.<ScheduleNextThread>b__2(System.Object)
       at System.Threading.ExecutionContext.RunInternal(System.Threading.ExecutionContext, System.Threading.ContextCallback, System.Object, Boolean)
       at System.Threading.ExecutionContext.Run(System.Threading.ExecutionContext, System.Threading.ContextCallback, System.Object, Boolean)
       at System.Threading.QueueUserWorkItemCallback.System.Threading.IThreadPoolWorkItem.ExecuteWorkItem()
       at System.Threading.ThreadPoolWorkQueue.Dispatch()
    Faulting application name: vmmservice.exe, version: 3.1.6011.0, time stamp: 0x50aaba3f
    Faulting module name: unknown, version: 0.0.0.0, time stamp: 0x00000000
    Exception code: 0xc0000005
    Fault offset: 0x000007fae7615fdb
    Faulting process id: 0x1050
    Faulting application start time: 0x01ce1b77516905f8
    Faulting application path: F:\Program Files\Microsoft System Center 2012\Virtual Machine Manager\Bin\vmmservice.exe
    Faulting module path: unknown
    Report Id: a450c591-876d-11e2-93fe-00155d011c01
    Faulting package full name:
    Faulting package-relative application ID:
    Its important that this error occurs only with my Windows 2012 Datacenter cluster, with a Windows 2008R2 Cluster doesn't, and works perfect the registration.
    What's going wrong???
    Thank you very much.

    Dear All,
    I can't find a solution for this error....
    Faulting application name: vmmservice.exe, version: 3.1.6011.0, time stamp: 0x50aaba3fFaulting module name: KERNELBASE.dll, version: 6.2.9200.16451, time stamp: 0x50988aa6Exception code: 0xe0434352Fault offset: 0x000000000003811cFaulting process id: 0x1070Faulting application start time: 0x01cf1b5d8e2c9535Faulting application path: C:\Program Files\Microsoft System Center 2012\Virtual Machine Manager\Bin\vmmservice.exeFaulting module path: C:\Windows\system32\KERNELBASE.dllReport Id: e35b1662-8750-11e3-9417-00155d00795aFaulting package full name: Faulting package-relative application ID: 
    I've a cluster with 2 nodes.
    1) The NIC teaming is configured in the cluster (the VMM is installed in one VM in the cluster).
    2) yes
    3) yes
    Thanks a lot for the replies!
    SF

  • Error in connecting App Controller to SCVMM 2012 R2

    Hello All,
    I have recently installed App Controller 2012 R2 on a new VM. We are already using SCVMM 2012 R2 with Update Rollup 4.
    I'm logged-in on the App Controller website with the service account of App Controller/SCVMM.
    Now when I'm trying to connect App Controller to SCVMM server, it gives the following error:
    "Category: Critical
    Description: Connection attempt to the target system failed.
    Details: Category: Critical
    Message: 553–RegistryInvalidValue
    Description: The type or name syntax of the registry key value IndigoTcpPort under Software\Microsoft\Microsoft System Center Virtual Machine Manager Administrator Console\Settings is incorrect."
    I'm correctly entering the complete FQDN of my VMM management server, and the default port: 8100.
    Need help please.
    Thank you.
    Regards
    Hasan Bin Hasib

    Hi Hasan,
    I haven't seen this issue before, but the following post provides information on checking the registry value:
    https://wmoore.wordpress.com/2014/04/11/appcontroller-2012-r2-vmm-registration-error/
    The usual caveats about editing the registry apply, including make a backup first.
    Regards
    Richard
    This posting is provided "AS IS" with no warranties, and confers no rights.

  • App v package distribution issue to sccm 2012 DP

    Hi,
    We are migrating app-v 4.6 packages to sccm 2012 , after importing the packages when we update DP its not copying the dependent scripts inside the appv package to Dp and hence when application launches it fails to launch the vb script.
    the script is made to run when shortcut is launched, but no vb script is copied to DP , but I have all files intact in source folder iyt just copies .sprj,xml,osd.
    Please suggest how to make all the files in package abcd.001 to get copied in DP.
    Does App-v package distribution is different from normal package.
    Thanks
    Shuaib

    Open up the app in the sequencer, add the file to your scripts folder. If the script requires to be run elevated, you'll want to use the Deployment config file and use Global publishing....
    If you don't need elevation you can use the User Config and won't need to publish globally.
    Fore more info and some examples, check this out:
    http://blogs.technet.com/b/appv/archive/2012/12/10/scripting-and-embedded-scripting-for-appv-5-0-dynamic-deployment-and-user-configuration-scripting.aspx
    PLEASE MARK ANY ANSWERS TO HELP OTHERS Blog:
    rorymon.com Twitter: @Rorymon

  • Live Migration between two WS2012 R2 Clusters with SCVMM 2012 R2 creates multiple objects on Cluster

    Hi,
    I'm seeing an issue when migrating VM's between two 2012 R2 Hyper-V Clusters, using VMM 2012 R2, that have their Storage provided by a 4 Node Scale Out File Server Cluster that the two clusters share.
    A migration between the two clusters is successful and the VM is operation but I'm left with two roles added to the cluster the VM has moved to instead of the expected one.
    For example: Say I have a VM that was created on cluster A with SCVMM, resulting in a name of : "SCVMM Test-01 Resources"
    I then do a live migration to Cluster B which has access to the same storage and then I end up with two new roles instead of one.
    "SCVMM abw-app-fl-01 Resources" and "abw-app-fl-01"
    The "SCVMM abw-app-fl-01 Resources" is left in an unknown state and "abw-app-fl-01" is operational.
    I can safely delete "SCVMM abw-app-fl-01 Resources" and everything still works but it looks like something is failing during the process.
    Has anyone else seen this?
    I'll probably have one of my guys open a support ticket in the new year but was wondering if anyone else is seeing this.
    Kind regards,
    Jas :)

    In my case the VMs where created in VMM in my one and only Hyper-V cluster (that's been created and is managed by VMM).
    All Higly Available VM:s have a FCM role named "SCVMM vmname" where vmname is the name if the VM in VMM. On top of that a lot
    of VM:s, but not all,  have a second role name named vmname. Lots of name in that sentence.
    All VMs that have duplicates are using the role named vmname.
    I thought it had to do with whether a VM had been migrated so I took one that never had been migrated and did. It did not get a duplicate.
    Is there any progress on this?

  • Errors Performing V2V Conversions from ESX 5.5 to Hyper-V 2012 R2 using SCVMM 2012 R2

    I've successfully added my vSphere server and 2 ESXi 5.5 hosts to my SCVMM 2012 R2 server.
    I have also added my 2 Hyper-V 2012 R2 hosts as well.
    When I attempt to do a V2V conversion of a VM from 1 of my ESX hosts to Hyper-V, I receive - "Error (2901) The operation did not complete successfully because of a parameter or call sequence that is not valid. The parameter is incorrect."
    When I go into the details of the job in VMM it shows "1.4 Convert VMDK to virtual hard disk - Failed" and "1.4.1 Deploy file (using HTTP) - Failed"
    Any help resolving this would be appreciated.
    Also, I can do V2V conversions using the same ESX and Hyper-V hosts without any issues using Microsoft Virtual Machine Converter 2.0, but my manager wants me to use VMM.
    Thanks!

    Quite honestly, building fresh on the platform and migrating the apps / services is always the best way to go
    PlateSpin was the last product I knew that had a Linux conversion utility.   Even found this:
    http://blogs.technet.com/b/enterprise_admin/archive/2010/04/26/hyper-v-linux-p2v-with-platespin.aspx
    No idea the current status of PlateSpin.  They were the gold standard back in 2008.
    But honestly, it can be painful.  It all depends on the hardware now.
    With Hyper-V the end boot device is IDE - so if the machine now runs on SCSI, the boot loader pointers need to be modified (if you can find a tool to bring the disk forward).
    Now, that said.  Hyper-V can convert a physical disk to VHD.  That is a stealth feature that has been there from the beginning.  I can't recall if it is block by block, or if the file system must be known for the copy to succeed.
    You mount the disk on the Hyper-V Server and create a new VHD from a physical disk.
    The biggest issue with the conversion utilities is that Windows does not know the Linux file systems.  So you need some Linux tool to do it.
    I know that VMware had a converter that handled Linux - but again, you have to manually fixup the hardware in the boot menu.
    Brian Ehlert
    http://ITProctology.blogspot.com
    Learn. Apply. Repeat.

  • Unable to reinstall SCVMM 2012 R2 during database migration - access denied to VMMDKM container

    I'm trying to migrate my SCVMM 2012 R2 DB to a new SQL 2012 server. As per TechNet article http://technet.microsoft.com/en-us/library/dn469626.aspx,
    I uninstalled VMM, which went without a problem. During the reinstall, setup fails with "Unable to create or access the Active Directory container CN=VMMDKM,CN=System,DC=feroscare,DC=local. Access is denied. Specify the distinguished name
    for the container and verify that you have GenericRead|CreateChild|WriteProperty rights on the container." - as is shown in the setup log below.
    I'm trying to use the same account as the service account and to connect to the database. I'm logged into the VMM server as that user account (and running setup as that account). I have verified that the account has full control over the VMMDKM container
    and all descendant objects. I've also added these permissions for the VMM server's computer account, although I'm not sure that's necessary.
    VMM server is running Win 2012 R2, SQL server is 2012 running on Win 2012 R2. Domain controller is running 2008 R2 with AD at the 2003 functional level.
    Please can anyone please advise what to do next to troubleshoot this?
    What seem to be the relevant lines from the VMM setup log:
    "12:33:04:Error:SetupDKM method threw. See inner exceptions, Exception Type: System.DirectoryServices.DirectoryServicesCOMException, Exception Message: A constraint violation occurred.
    12:33:04:StackTrace:   at System.DirectoryServices.DirectoryEntry.CommitChanges()
       at Microsoft.Incubation.Crypto.GroupKeys.ADRepository.AddAccessRule(IdentityReference identityReference, ActiveDirectoryRights rights)
       at Microsoft.VirtualManager.Setup.DKMHelper.SetupDKM(String containerName, String topContainerName)
    12:33:04:VMMPostinstallProcessor threw an exception: Threw Exception.Type: Microsoft.VirtualManager.Setup.Exceptions.BackEndErrorException, Exception.Message: Unable to create or access the Active Directory container CN=VMMDKM,CN=System,DC=feroscare,DC=local.
    Access is denied.
    Specify the distinguished name for the container and verify that you have GenericRead|CreateChild|WriteProperty rights on the container.
    12:33:04:StackTrace:   at Microsoft.VirtualManager.Setup.DKMHelper.SetupDKM(String containerName, String topContainerName)
       at Microsoft.VirtualManager.Setup.DKMHelper.SetDKM(Boolean isDKMEnabled)
       at Microsoft.VirtualManager.Setup.InstallItemCustomDelegates.PangaeaServerPostinstallProcessor()
    12:33:04:InnerException.Type: System.DirectoryServices.DirectoryServicesCOMException, InnerException.Message: A constraint violation occurred.
    12:33:04:InnerException.StackTrace:   at System.DirectoryServices.DirectoryEntry.CommitChanges()
       at Microsoft.Incubation.Crypto.GroupKeys.ADRepository.AddAccessRule(IdentityReference identityReference, ActiveDirectoryRights rights)
       at Microsoft.VirtualManager.Setup.DKMHelper.SetupDKM(String containerName, String topContainerName)
    12:33:04:ProcessInstalls: Running the PostProcessDelegate returned false.
    12:33:04:ProcessInstalls: Running the PostProcessDelegate for PangaeaServer failed.... This is a fatal item.  Setting rollback.
    12:33:04:SetProgressScreen: FinishMinorStep.
    12:33:04:ProcessInstalls: Rollback is set and we are not doing an uninstall so we will stop processing installs"
    Thanks in advance!

    Hi new_guise,
    Please refer to following link regarding "Reinstalling VMM with a Retained Database" :
    http://technet.microsoft.com/en-us/library/cc764334.aspx
    Also please refer to following article regarding that error message :
    http://support.microsoft.com/kb/2721457
    Best Regards,
    Elton Ji
    Please remember to mark the replies as answers if they help and unmark them if they provide no help. If you have feedback for TechNet Subscriber Support, contact [email protected] .

  • Subscription and volume licensed Office 365 C2R App-V packages on the same computer

    I'm interested if anyone has come across a similar scenario to what we have at the organisation I am currently working for. The organisation has signed up for an E3 subscription to Office 365, however would like to continue to using their volume licenses
    of Visio and Project 2013 (at least until new versions are released at which point they'll likely move to the same subscription model).
    Using the Office Deployment Tool, I've created App-V 5.0 SP2 packages for
    a. "O365ProPlusRetail"
    b. "ProjectProVolume" and "VisioProVolume"
    Both App-V packages ignore any exclusion rules in the configuration.xml file I've defined. This is expected and I can control which applications are published using Config Mgr 2012 R2. Both packages deploy and run as I would expect.
    The issue I specifically have is that if I publish both App-V packages (using different package ID's) to the same PC with modified DeploymentConfig.xml files:
    a. "O365ProPlusRetail" package only enables Word, Outlook and Excel (subscription licensing)
    b. "ProjectProVolume/VisioProVolume" package only enables Visio and Project (volume licensed)
    it appears as though the Word, Excel and Outlook from (b) are utilised instead of from (a) even though they are specifically disabled. This means that Word, Excel and Outlook activate to our local KMS server, rather than using the user credentials as we would
    prefer.
    To confirm I can see that package (a) is already running when I run the following command: Get-AppvClientPackage | select Name, InUse, InUseByCurrentUser
    Name                                                                                         
    InUse                                InUseByCurrentUser
    Microsoft Office 15 ProjectProRetail_O365ProPl...                                             
    True                                             
    True
    Microsoft Office 15 VisioProVolume_ProPlusVolu...                                             
    False                                            
    False
    If I then open Word (which should only be enabled in the first package), I see that the second package is now in use
    Name                                                                                         
    InUse                                InUseByCurrentUser
    Microsoft Office 15 ProjectProRetail_O365ProPl...                                             
    True                                             
    True
    Microsoft Office 15 VisioProVolume_ProPlusVolu...                                             
    True                                             
    True
    I've also confirmed that all the applications (besides Visio and Project) are disabled in the second package:
    Name                                                                                                                                 
    EnabledGlobally
    Database Compare 2013                                                                                                                          
    False
    Spreadsheet Compare 2013                                                                                                                       
    False
    Excel 2013                                                                                                                                     
    False
    OneDrive for Business 2013                                                                                                                     
    False
    InfoPath Filler 2013                                                                                                                           
    False
    Lync 2013                                                                                                                                      
    False
    Access 2013                                                                                                                                    
    False
    Telemetry Log for Office 2013                                                                                                                  
    False
    Telemetry Dashboard for Office 2013                                                                                                            
    False
    Office 2013 Upload Center                                                                                                                      
    False
    Publisher 2013                                                                                                                                 
    False
    Lync Recording Manager                                                                                                                         
    False
    Microsoft Outlook Mobile Service                                                                                                               
    False
    OneNote 2013                                                                                                                                   
    False
    Send to OneNote 2013                                                                                                                           
    False
    Organization Chart Add-in for Microsoft Office programs                                                                                        
    False
    Outlook 2013                                                                                                                                   
    False
    PowerPoint 2013                                                                                                                                
    False
    Microsoft Office 2013                                                                                                                          
    False
    Office 2013 Language Preferences                                                                                                               
    False
    SharePoint Designer 2013                                                                                                                       
    False
    Visio 2013                                                                                                                                      
    True
    Project 2013                                                                                                                                    
    True
    Word 2013                                                                                                                                      
    False
    Office XML Handler                                                                                                                             
    False
    Internet Explorer                                                                                                                              
    False
    Notepad                                                                                                                                        
    False
    Perhaps what I am trying to do is unsupported but I can't find anything explicity calling this out - and surely other organisations will have a similar scenario to us. Is there any best practice recommendations from Microsoft in this regard?
    Cheers, Tim

    here is some reference, hope it's helpful.
    http://support.microsoft.com/kb/2915745
    http://technet.microsoft.com/en-us/library/jj219422(v=office.15).aspx
    http://technet.microsoft.com/en-us/library/hh852466.aspx

  • Creating Lync and OneNote App-V Packages

    I need to create an App-V package for Lync 2013 and another for OneNote 2013. From
    this KB article it appears that the valid product ID's I can use in ODT are all retail versions. I want to do volume licensing from my KMS server. Is it okay to use the product ID's LyncRetail and OneNoteRetail?
    Am I going about this all wrong?
    John Marcum | Microsoft MVP - Enterprise Client Management
    My blog: System Center Admin | Twitter:
    @SCCM_Marcum | Linkedin:
    John Marcum

    Hi John,
    Thanks for your post.
    When creating the App-V package for Volume Licensing editions, it will require the Product ID in the configuration.xml file to be like “ProPlusVolume”, “StandardVolume”, “VisioProVolume” or “ProjectProVolume”.
    So I am assuming you might want to try with "LyncVolume" and "OneNoteVolume" in your configuration.xml file.
    For more information, please refer to these blog posts:
    http://blogs.technet.com/b/office_resource_kit/archive/2013/12/02/announcing-app-v-5-0-sp2-support-for-office-2013-volume-licensing-editions.aspx
    http://blogs.technet.com/b/pauljones/archive/2013/08/28/office-2013-click-to-run-with-configuration-manager-2012.aspx
    Thanks,
    Ethan Hua CHN
    TechNet Community Support

  • Slow Mount for App-V Packages

    Hi,
    I'm having an issue I first noticed with App-V 5 sequence packages deployed via ConfigMgr 2012 SP1 that are taking forever to mount.
    To rule out ConfigMgr i've manually copied an app-v package (around 1GB) and ran the following powershell commands locally on a test client...
    Add-AppvClientPackage -Path "path to package" | Publish-AppvClientPackage -Global | Mount-AppvClientPackage -Verbose
    The mount command takes around 25-35+ minutes to complete, which is the behaviour i'm seeing when ConfigMgr deploys the package to a client.
    If i was to just run the MSI from the same sequenced App-V Package on a client system this would complete a number of minutes.
    Whats the difference between how and what the MSI installer does and why is the mount command taking so long?
    App-V version is 5.0 SP1.
    Thanks,
    Doug

    +1
    We similarly have 30 - 45 minute mount times particularly for the larger Autodesk products (using App-V Server infrastructure) compared to 2 - 3 minutes for exactly the same package sequenced in 4.6.
    I raised a ticket with Microsoft and initially figuring it must be something in the way we were sequencing in 5.0. They played with one or two of our packages and gave a few tips to tidy up the packages, told us there were general performance issues at that
    stage with 5.0 but essentially there was no answer. To us, a package taking 20 minutes to load against 30-45 does not real make a huge difference. It is not acceptable coming from what we had with 4.6.
    I was told that a Hotfix was due to be released immediately after SP2 that would deal with some of the "performance issues" but no sign yet.
    We have been rolling out Windows 8.1 across our regional offices and have taken to sticking a member of IT in all of the App-V Groups that are required for the local office and doing the Mount on the weekend as part of the install. We can't be rolling
    out Windows 8.1 and then having the guys come in on a Monday and telling them they can't use any Apps for 2 hours. I'd be laughed out of the office.

  • App-V packages not streaming on VMWare View VDI

    Hello All,
    We are currently running SCCM 2012 R2 CU2 on VMware View VDI's.
    We maintain our golden image using SCCM OSD.
    NExt to applications installed in the image, we are also using app-v packages.
    Before we can deploy the image, it needs to be stripped (or sysprepped) so as to garantuee that the clones will not report to the Management Point using the same SCCM Guids etc.
    There for we perform the following:
    net stop "CcmExec"
    Remove-Item c:\windows\smscfg.ini
    Get-ChildItem -Path cert:\LocalMachine\SMS | Remove-Item
    Get-wmiObject -Namespace root\ccm\invagt -class inventoryActionStatus | where {$_.inventoryactionID -eq "{00000000-0000-0000-0000-000000000001}" } | remove-wmiobject
    Clear-EventLog -logname Application
    Clear-EventLog -logname System
    Clear-EventLog -logname Security
    Get-ChildItem c:\windows\ccm\logs | remove-item
    When we deploy the new version of an image, we see that APP-V packages are not being streamed immediately to the clients.
    While troubleshooting, I noticed that whenever I login and run a Machine Policy Evaluation & Retrieval cycle, that a ccmrepair and ccmrestart is being executed.
    After the restart, the client immediately starts streaming the App-V packages.
    Can anyone help me in pinpointing where the ccmrestart gets triggered from?
    I've searched to already a lot of logs (ccmexec, execmgr, policyagent, policyevaluator,..) for the root cause but am unable to find it.
    Many thanks in advance!
    Filip Theyssens

    Hi,
    I just ran the action "Machine Policy Evaluation & Retrieval cycle" on my client, the Ccmrepair and Ccmrestart were not being executed from the logs.
    You could trigger the CcmRestart by running "%windir%\CCM\CcmRestart.exe".
    Best Regards,
    Joyce
    We
    are trying to better understand customer views on social support experience, so your participation in this
    interview project would be greatly appreciated if you have time.
    Thanks for helping make community forums a great place.

  • SCVMM 2012 SP1 (RTM) Deployment from VMM Console fails.

    Error During a library refresh, or deployment from template - It all fails:
    Error (12710)
    VMM does not have appropriate permissions to access the Windows Remote Management resources on the server (MyServer).
    Unknown error (0x80338105)
    Recommended Action
    1) Ensure that the Windows Remote Management (WS-Management) service is running on the server (myserver).
    2) If the System Center Virtual Machine Manager service on your VMM management server is configured to run by using the machine account, ensure that there is not a group policy that does not allow adding machine accounts to a computer's Administrators group.
    If there is, you can use one of the following workarounds:
      - Disable the group policy in Active Directory Domain Services (AD DS)
      - Modify the group policy to allow the VMM machine account in the Administrators group
      - Move the machine account to its own organizational unit (OU) and block the group policy from being applied
      - Reinstall the VMM management server and choose the option to run the System Center Virtual Machine Manager service by using a domain account, and re-add all of your virtual machines.
    So, as soon as SCVMM 2012 Sp1 was released we decided that it was best to upgrade so we could utilise the new features of Server 2012 as a host.
    The upgrade worked a treat. VM's deployed, Server 2012 worked. Anyway, a few days after deployment we start to see errors relating to WinRM and permissions (See end of the post). After a quick trace around we found some failed services, usually on a host
    but sometimes it seemed to happen on the Library/Management server as well.
    So, our setup is as follows:
    Management/Library server = VMware  VM, Server 2012 standard, 6 GB memory, 4 vCPU's
    Hosts = HP DL360p G7, HP DL360 Gen8 (we have a few of these), Server 2012. We also have a DL380 G7 on Server 2008 R2 Enterprise that fails as well, so it seems the error isn't O/S specific (I'm picking a VMM issue).
    So I have tried many resolutions and now none of them work.
    We have no restrictions on group policy for the local admin, this can be set manually, and works for that matter.
    WinRM is working and the listening port is 5985 (I can see it working and listening via a "netstat -an")
    Also, I have ensured many many times that all of the required services are up and running (SCVMMAgent, VirtualDisk managerment, WinRM) and initially these where at fault and a simple restart of each service (or even a full start from dead) fixed
    it - Now it all fails. Even a library refresh fails. And all while each of the services required are up and running.

    So, I have now tried a reinstall of the management server & made some changes
    1- Changed the service account during the install.
    2 - Added the service account user to the local admins group of each host in question.
    3 - Tried "winrm /qc" .which lets me know its already up and running and configured. Although I must admit, I'm not 100% sure how to use WinRM. From what I can read, this is like an express setup and ensures you are up, running and listening.
    4 - Verified that WinRM is working of the right port (Listening ports dump below)
    5 - Verified that I can connect to each port required for the SCVMM Management server.
    BUT, it seems the error is still there and deployments still fail,
    although the library refreshes correctly now.
    Error (12710)
    VMM does not have appropriate permissions to access the Windows Remote Management resources on the server ( Myserver).
    Unknown error (0x80338105)
    NETSTAT Listening ports dump.
    PS C:\Users\nzadmin> netstat -an
    Active Connections
      Proto  Local Address          Foreign Address        State
      TCP    0.0.0.0:135            0.0.0.0:0              LISTENING
      TCP    0.0.0.0:443            0.0.0.0:0              LISTENING
      TCP    0.0.0.0:445            0.0.0.0:0              LISTENING
      TCP    0.0.0.0:1801           0.0.0.0:0              LISTENING
      TCP    0.0.0.0:2103           0.0.0.0:0              LISTENING
      TCP    0.0.0.0:2105           0.0.0.0:0              LISTENING
      TCP    0.0.0.0:2107           0.0.0.0:0              LISTENING
      TCP    0.0.0.0:3389           0.0.0.0:0              LISTENING
      TCP    0.0.0.0:5985           0.0.0.0:0              LISTENING
      TCP    0.0.0.0:8000           0.0.0.0:0              LISTENING
      TCP    0.0.0.0:8100           0.0.0.0:0              LISTENING
      TCP    0.0.0.0:8101           0.0.0.0:0              LISTENING
      TCP    0.0.0.0:8102           0.0.0.0:0              LISTENING
      TCP    0.0.0.0:8103           0.0.0.0:0              LISTENING
      TCP    0.0.0.0:47001          0.0.0.0:0              LISTENING
      TCP    0.0.0.0:49152          0.0.0.0:0              LISTENING
      TCP    0.0.0.0:49153          0.0.0.0:0              LISTENING
      TCP    0.0.0.0:49154          0.0.0.0:0              LISTENING
      TCP    0.0.0.0:49155          0.0.0.0:0              LISTENING
      TCP    0.0.0.0:49156          0.0.0.0:0              LISTENING
      TCP    0.0.0.0:49170          0.0.0.0:0              LISTENING
      TCP    0.0.0.0:49201          0.0.0.0:0              LISTENING
      TCP    0.0.0.0:49211          0.0.0.0:0              LISTENING
      TCP    127.0.0.1:57388        0.0.0.0:0              LISTENING
      TCP    172.23.16.69:139       0.0.0.0:0              LISTENING

  • How to get the details of a LUN (Storage Logical Units) presented to an ESX host thru SCVMM 2012

    Hi,
    We are working with a UI Add-in for SCVMM 2012 where we should support both Hyper-v and ESX hosts. When added the ESX host and presented few LUNs (out of band operation) from the HP 3PAR array,
    we are unable to view the Storage details like Storage Logical unit, Storage Pool and Storage Array when we select the same LUN in the Classification and Pools section of SCVMM.
     We tried even with the PowerShell, but couldn’t help. Can you please guide us, how we can get the storage details of a LUN presented to the ESX host which is added in the SCVMM 2012.
    Thanking you.
    Regards,
    Hari

    Hi Jiannan,
    No worries, you can go to UDDI client from the main page of PI  i.e. http://<serverName>:<serverPort>/
    And you use the search function for  the TModel for your Physical System. Search parameters can use the % wildcard.
    Hit the search and you find the UDDI Key for the Physical System.
    Cheers.
    Hemant Chahal

  • SCVMM 2012 R2 deploy network problem

    Hi,
    I'm trying to set up the network on SCVMM 2012 R2 according to the several documentation and I'm finding a problema trying to deploy my simple design.
    Basically I need to create two network environments completelly isolated from each other. The servers have one NIC connected to these networks, and what I have configured is two logical networks with some networks sites, the uplinks and logical switch, there
    is a Virtual network per logical network to connect the VMs... all seems to be ok, I add this two logical networks to the hosts but when I want to configure the networking in the virtual machine, I only see one logical network, I can't choose the environment
    I want... I don't know what I'm doing wrong...
    Thanks in advanced...

    "How should I configure networking in SCVMM to allow one virtual machine to connect to the same subnet using two network interfaces?"
    You can achieve this by simply adding multiple vNICs to a VM - connected to the same VM Network. 
    -kn
    Kristian (Virtualization and some coffee: http://kristiannese.blogspot.com )

  • Can't able to add update server to fabric in SCVMM 2012 R2

    Hi,
    I have one windows server 2012 R2 standard machine (update server) with WSUS, I have installed from server manager as server role. This update server machine is having the public IP without domain and it is a VM on one of my Hyper-V server. I would like
    to add the update server to my SCVMM 2012 R2 environment. When I try to add the update server to the fabric, it can't seems to be add because its throwing the error like, "Error (410) Agent installation failed on update server. The RPC
    server is unavailable."
    Has anybody else have clue ?
    Can anybody offer some help ?

    Hi,
    following link provides info on how to add untrusted Hyper-V hosts to VMM
    http://technet.microsoft.com/en-us/library/gg610609.aspx
    as it might help you adding an untrusted WSUS also (haven't tested it myself)
    MCITP SA - MCP Active Directory - MCP Infrastructure - MCP Server Virtualization www.it101.eu

Maybe you are looking for

  • Unable to Install oracle lite 10g mobile server on windows

    Hi all, Basically I am a .net developer, i want to explore Oracle Lite 10g mobile database. for that I am trying to install Olite 10g Mobile server on my windows system it is installing upto 95%, after that nothing is happening. it is not giving any

  • Songs skip right in the middle of the song

    when I listen to some songs right in the middle of the song it just stops and skips for no reason. In the past i've seen this issue go right within the first 0-10 seconds of the sogn but this time it is in th e middle. What is causing this and how ca

  • Discoverer Bar Chart Data Points

    Hi everyone, I am creating a Bar Chart in Discoverer with the data points to be displayed at the top. Does anyone know how to make the datapoints not display decimal places. I've tried to change the number format in the table and through administrato

  • Brush error?

    Hi guys, I'm using Illustrator CS5 and seem to have run into some problems using the brush tool. The example below is using the default 7pt round brush at a size of 0.01pt. The problem is that a) the width of the brush doesnt stay consistent, it look

  • PB with french accent, and french character

    Hello, I have some problem to use, character like 'é' or 'à', ... i use form tag in Weblogic Portal 4.0, and when i get the data from the form, i have character like 'é' for any character who have a code greater than 128. There is some one who have