Automatic defect recording

Dear all
During recording result if ant characteristic is valuated as reject,a screen should pop up automatically for defect recording.but is not coming.so how can i do this .any configuration required in spro.

Hi
Pl check wheather you have ticked defects recording(in Results confirmation)and RR change docs (In miscellaneous)in your MIC
Regards,
Raj
Edited by: rajaram kulkarni on Jun 2, 2008 1:02 PM

Similar Messages

  • Duplication of Defect items when using the Automatic Defect recording

    Can someone help with this one:
    We are using the Defect Code for General rejection field (QPMK-CODEGRQUAL) in some Qualitative characteristics.
    When we record a rejected result for these characteristics, the system creates a Quality Notification as expected, but the Notification Item detail tab contains two identical defect items, instead of just one. Both items have the same created_by information and the identical creation time.
    I have looked through OSS for any reference to this problem, and cannot find anything, but I'm pretty sure it is a bug.
    We are on ECC60.
    Thanks for your help!

    Hi Chris,
    Program RFDM3000 creates dispute cases for residual items arising during automatic incoming payments (account statement, lockbox), during check presentation, or in postprocessing.
    Alternatively, you can use the program to create dispute cases for open receivables items. You can use the selection criteria to restrict the quantity of open items (for example, using the document type and posting key for residual items from incoming payment postings).
    You will find more information in the link below
    http://help.sap.com/saphelp_erp2004/helpdata/en/0b/e07340b0c6980ae10000000a155106/content.htm
    Regards,
    Jose

  • Defects Recording in QE11

    Hi
    Can anyone sugggest me bapi for recording defects after the results recording in QE11. I am using BAPI_INSPOPER_RECORDRESULTS  for results recording but there is no option for defects recording in that bapi.
    can anyone suggest me an appropriate bapi for the same.
    Thanks & Regards
    Manoj

    Dear JJ
    The defect recording tick in the mic is for automatic defect recording. What this means is if an inspection characteristic is rejected during results recording, the function for recording defects for a characteristic is automatically called up. Defects recording in the background is done if you define defect codes in the inspection characteristic.You can specify three defect codes for a quantitative characteristic:A defect code for a general rejection,A defect code for a rejection at an upper specification limit,A defect code for a rejection at a lower specification limit
    If you do not need this functioanlity remove the tick from MIC. You can anyway o defect recording without this tick also
    Hope this helps
    Regards
    Gajesh

  • Defects Recording  in MIC

    Hello
    When we set this indicator , i am getting a warning message in QS21 / QP01. I already assigned the code 9 to the relevant plant .
    But the warning message was suppressed if i assign any one of the code from code 9 in MIC or Inspection plan .
    What was the concept behind it ?
    I want to use the code in the defects recording only
    Thanks
    JJ

    Dear JJ
    The defect recording tick in the mic is for automatic defect recording. What this means is if an inspection characteristic is rejected during results recording, the function for recording defects for a characteristic is automatically called up. Defects recording in the background is done if you define defect codes in the inspection characteristic.You can specify three defect codes for a quantitative characteristic:A defect code for a general rejection,A defect code for a rejection at an upper specification limit,A defect code for a rejection at a lower specification limit
    If you do not need this functioanlity remove the tick from MIC. You can anyway o defect recording without this tick also
    Hope this helps
    Regards
    Gajesh

  • Automatic POP screen for Defect Recording

    Hi,
    I am working at Result recording, my client want to record the defect at time of result recording with help of Automatic POP screen of defect overview. I did not find the assignment for automatic POP screen for Defect,
    Pl helps me for finding that solution

    Hi,
    You can get the automatic POP screen for Defect Recording after you Reject the characteristics in the result recording. For that you need to flag the Defect recording check box in the control indicators of the inspection characteristics.
    If you are using the task list then select the inspection characteristics and then click on the control indicators. Flag (check) the Defect recording check box in the tab results confirmation.
    If you are using the master inspection characteristics the click on the control indicators and flag (check) the Defect recording check box in the tab results confirmation.
    By this way you can get the pop up. You can also get the automatic defect codes assigned to your result recording after rejecting. For that you need to assign the defect code in the catalogs of your inspection characteristics or master inspection characteristics.
    Please give points if found useful.
    Regards,
    Manoj

  • Deactivate Quality Notification During Defect Recording

    Hi,
    How will I deactivate the Quality Notification Tabs during Defect Recording? Because it is showing a red traffic light which user dont want to see and mis understood that there is something wrong.
    Thank you,
    Raymond

    Hi
    What you can do is remove the creation of automatic notification in the background.
    QCC3->inspection lot creation>Maintain Inspection type->select inspec type--->remove defualt " notification type".
    This will neither create notification nor give pop-up.
    Sujit

  • Code Group on defect recording

    Hi guys,
    When I do my defect recording for an inspection characteristic using QE51N, I notice that when I clicks on the Code column, a screen pops up (i.e. Catalog Selection screen), there are three Code Group (i.e. defect types) and its relevant codes.
    My question is how on earth that the system automatically pull out these three defect types for this inspection characteristic when I didn't assign these defect types into this inspection characteristic
    Does it means when I create the code group A at QS42 using Catalog 9, this code group A will appears on the defect recording screen whenever I want to perform the defect?
    Am I right?
    Thanks

    Yes
    Whenever u record defects all code groups with their codes in catalog 9 will appear.
    U can avoid this by activating 'defect recording' tick in characteristic control indicator.
    then in catalogs enter catalog 9 and give relevent code groups.
    Now whenever u record defects of this material it will show u only these defects.

  • Stock Posting during Defects recording

    Dear experts,
       can any one help me for the below scenario,
      1. During Defects recording the rejected stock should post automatically to the respective stolrage location.
    thanks in advance
    muthamil

    Hi,
      Thanks for your response , my client requirement is  as follows,
      1. Can we have Automatic posting of Accepted stock / Rejected stock after entering the Defects in Defects Recording? (to avoid wrong entry of stock posting)
    2. " Results were recorded wrongly and UD given and stock posting done. Is there any procedure to rewrite the Results?
    Is there any solution for the above scenario
    Thanks
    GM

  • Defect recording

    hello guys,
    I have a requirement that if the part got failed at the incoming inspection,some thing should trigger the quality notification before they do the UD rejection.Normally, we will click the defect icon at the RR to process quality notification manually.
    But is there any way that if somebody forgot to click the defect at RR and if they directly trying to do the UD ,it should have some control to restrict him and say to process quality notification ?
    I agree even if we forget they can manually write the quality notification thru qm01 but they dnt like that and they need some cntrol on this.
    I saw some defect recording option at MIC control indicators .....is that helps on my rqmt ?
    Pls advice
    Akash

    Hi
    I hope youi have done following cofig:
    QCC0>Quality inspection>maintain Inspection type>select 01 inspection type>Notification type:F2
    Now
    QCC0>quality planning>Basic data>Define catlog  Class>select class -->Click on Active notification.
    If you set this indicator, the quality notification (already existing) is immediately activated, when the defect data record is created. This means, that the quality notification receives the status "Outstanding notification" (OSNO).
    That means Notification will automatically remain in OSNO even if user do not create it manually.
    even if user forget to trigger it it will be geenarted & remain open.
    This will solve your problem
    Regards
    Sujit

  • I'm trying to record only part of my screen using my Quicktime 10.0, but once I press record in the "Screen recording" feature it automatically starts recording and doesn't give me the option to choose what part of the screen to capture. What gives?

    I'm trying to record only part of my screen using my Quicktime 10.0, but once I press record in the "Screen recording" feature it automatically starts recording and doesn't give me the option to choose what part of the screen to capture. What gives?

    QuickTime version 10 can only record the entire screen.
    10.1, 10.2 and 10.3 offer part of the screen recording.

  • Canon Rebel T5i automatically stops recording after about 6 seconds. How can I disable or fix this?

    I just got a Canon Rebel T5i and I was testing out the video and several times it will automatically stop recording after about 6 seconds. How can I fix or disable this?

    And while buying said faster card... buy a REPUTABLE brand from a reputable vendor.  I've come to the conclusion that there are a lot of fly-by-nights making cards that are not as fast as they claim to be.
    Reputable vendors are companies like Sandisk and Lexar.  But as an SD card is just a plastic card with a sticker on it, and stickers are pretty easy to fake, buy the card from a vendor you can trust is not selling fakes. 
    This is one item where it is probably not a good idea to try to save money by finding the cheapest deal you can find on the Internet.
    Tim Campbell
    5D II, 5D III, 60Da

  • Powershot SX510 HS automatically stops recording video after 10 - 15 minutes into the recording.

    Powershot SX510 HS automatically stops recording video after 10 - 15 minutes on continuous recording. Is there a way to turn this off? I would like to record videos until either I press the stop recording button, or the battery gets low. I have turned off all the power saving setting, at least I think I have.
    Solved!
    Go to Solution.

    The camera has some recording limitations as all the Canon models do. Below is how you can extend your recording times to a max of about 1 hour but there is a 4BG limit regardless so once it hits 4GB the recording stops and has to be restarted.
    Also the memory card needs to be at least a Class 6 rating or the recording will stop sooner regardless of the clip size.
    This is from page 161 of your manual

  • Tables for Defect type and its description while defect recording for a MIC

    Dear Experts,
    Kindly suggest the tables name  in  system by which we can get Defect type and its description that we have used while  performing defect recording for a MIC in system at the time of result reording for an inspection lot.
    Thanks in advance for your inputs ...
    Best regards ,
    Nitishj

    hii,
    Check
    QPAC - Inspection catalog codes for selected sets
    QPAM - Inspection catalog selected sets
    QPMK-CODEQUAL- Defect code grp for rejection at MIC level
    Link above table field name with QAVE for UD code & QAMR for Results recording
    Edited by: Lokesh K on Sep 29, 2010 10:43 AM
    Edited by: Lokesh K on Sep 29, 2010 10:45 AM

  • Extra Field in Defects Recording

    Hi Friends,
      As per my clients requirements i need to develop an extra field in the defects recording screen.Is there any standard program exist for this.
    Regards,
    S.P.Selvathangam

    Hi
    You explore with the following user exits
    Exit name text
    QEEM0003  xit: add. functions after valuating insp. characs
    QEEM0004  xit: add. functions after valuation of partial samples
    QEEM0006  xit: add. functions after closing inspection characs
    QEEM0007  xit: add. functions after completing partial samples
    QEEM0011  xit: add. functions before valuating insp. characs
    QEEM0012  xit: add. functions before valuating partial samples
    QEEM0015  xit: add. functions after entering individual results
    QEEM0020  xit: additional functions after entering the inspector
    QEEM0021  xit: additional functions for user key +US1
    QEEM0022  xit: additional functions for user key +US2
    QEEM0023  xit: additional functions for user key +US3
    QEEM0024  xit: additional functions for user key +US4
    QEEM0029  xit for Characteristic Overview Subscreen
    QEEM0030  xit for Subscreen: Characteristic Single Screen
    QEEM0031  xit for Table Structure with External Numbers
    QEEM0032  tation of the characteristic text in the logon lang.
    QEEV0003  ination of order type for print
    Regards
    YMREDDY

  • Suppression of automatic interaction record

    Hi All,
    I have a requirement like this:
    User entered the business partner and confirm the account.
    1) when user presses 'SAVE' button automatically interaction record will create(this is standard functionality working fine).
    2) when user enters customer note or reason code and presses enter , BADI CRM_IC_IARECORD method BEFORE_IR_CREATE  should trigger, here i need to check customer entered note or not.
    but at this point BADI is not triggering when user presses 'END' button.
    How to activate this BADI everytime when user presses 'END' button.
    Please give me advice , i am new CRM.
    Thanks,
    Rami.

    Hello Rami
    We did something similar whereby an IR would be created only if the reason field was populated and it works great. You need a good developer to help with this.
    We created logic whereby the IR was created when a certain field was populated else nothing was created. In order to suppress the Interaction Record save, it was necessary to enhance the component with the u201CCancelu201D and u201CEnd Buttonsu201D:
    Object(s) name     CRMCMP_IC_FRAME/HiddenView
    The htmlb_event->server_event that is handled by the view controller for the hidden view (ZL_CRMCMP_I_HIDDENVIEW_IMPL is the view controller) is u201CforwardCallu201D. So the handler method is EH_ONFORWARDCALL. This method was redefined.
    If either the u201CCancelu201D or u201CEndu201D button is clicked, the same htmlb_event is raised u2013 u201CforwardCallu201D, so the handler handles the same event for both buttons. It differentiates between the two buttons by the value that is held in attribute param1-value when the handler method is called. If the u201CCancelu201D button was clicked, then the value of this field would be 'CancelInteractionRequest', otherwise if the u201CEndu201D button was clicked it would be 'InteractionEndRequest'. These names correspond to the internal CRM event names.
    In order to effectively suppress the interaction record from saving it is necessary to perform the same logic that would be called by the event handler if the u201CCancelu201D button was pressed. In other words, if the user clicked the u201CEndu201D button, in order to suppress the interaction record the system needs to first execute the cancel logic and then the end logic. However, we donu2019t want to suppress the automatic save of the Interaction Record if the Interaction Record has been filled in and can tell if the interaction Record needs to be saved by the value in the u201Creason codeu201D field on the interaction record. So, the double step of first calling the u201CCancelu201D logic and then the regular u201CEndu201D logic must only occur if the u201Creason codeu201D on the Interaction Record is blank. This can be done for any fields..
    Regards
    Muneeb

Maybe you are looking for