Bluescreen on Win NT with AT/GPIB TNT!

I have a AT/GPIB TNT board and 488.2 version 1.60 software. The computer crashes randomly and the "blue screen" on NT always appears, with this line included: IRQL_NOT_LESS_OR_EQUAL ** -gpibclsd.sys
and sometimes
IRQL_NOT_LESS_OR_EQUAL ** -afd.sys
I´ve tried several things but none work except for when I run it without network connection.
Anyone have a good answer??
/Sohrab, Ericsson Microwave Systems

I have heard of this before but haven't been able to reproduce the error. If it works without a network connection/ you might want to try a different network interface card.
Just so you have the latest updates...
there's a patch for LabWindows/CVI 5.5, http://digital.ni.com/softlib.nsf/websearch/090082BECD7AC973862568EA005704EE?OpenDocument&node=132070_US
The latest VISA version, 2.6 can be downloaded from, ni.com > Support > Product Reference > Drivers and Updates > Current Versions, and for the latest Instrument Drivers refer, http://zone.ni.com/idnet97.nsf/browse/

Similar Messages

  • How to program VC++ with AT-GPIB-TNT

    I am a student in Taiwan and a beginner user in GPIB.
    I am writing a control program in Visual C++(console) on Win98 (by N.I. GPIB-TNT
    board).
    I need to control two devices one is Laser interferometer for measurement,
    another is PZT(piezo actuator).
    When I execute a simple read and write program,
    it always shows " can not read ".
    I am so confused.
    Can you help me to overcome this problem
    and show me a new simple program?!
    Thank you very much.....
    I am so appreciate for your help.
    best regards
    Andrew

    Andrew,
    From the bottom of http://www.ni.com/support/trouble/gpib/max/ibic.htm, there is
    a link to "Solutions to Common Errors." If you follow that link, the next page will
    have an entry for the EABO error code (and several other error codes). These tips
    are the suggestions that our support staff would make to you if you were to speak
    with them. I suggest checking that link out. I have posted this message to the
    newsgroup for the benefit of all readers.
    Regards,
    Rich
    NI
    Thanks for your help.
    After receiving your mail, I try to follow the step.
    But when I use "ibrd", it has the error code as follow
    iberr = EABO
    EABO indicates that an I/O operation has been canceled, usually due to a
    timeout condition after a GPIB read.
    Before reading from the instrument, verify that the GPIB command you are
    sending is understood by your device
    and instructs it to place data in its output buffer.
    device data as follow
    Board: GPIB0 AT-GPIB/TNT
    Device: Name Type
    Value Description
    instrument0 Instrument is not 488.2 compatible pad=2 GPIB
    instrument
    instrument1 Zygo, VMEbus control board pad=3 GPIB
    instrument
    My goal just want to read the measuring data from laser device by
    AT-GBIP/TNT board.
    Need your help again thanks.
    Andrew
    > Andrew,
    >
    > What you may want to do, instead of starting off with straight
    coding, is
    > to see if you can establish communication with the instrument using
    "IBIC," our
    > interactive diagnostic tool for instrument control. This program comes
    > installed with your 488.2 driver.
    >
    > To find out more about this, visit
    > http://www.ni.com/support/trouble/gpib/max/ibic.htm . If you can achieve
    > communication with your instruments with this program, you're well on your
    way.
    > If you cannot, the website has solutions to common errors that one can see
    while
    > using this tool.
    > ps. "threads" refer to the number of processes running at once. For
    example,
    > if you can do two separate math operations simultaneously in your program,
    > that's a multithreaded application.
    > "andrew" on 04/24/2000 03:51:13 AM
    > I am a student in Taiwan and a beginner user in GPIB.
    > I got your e-mail address from your post on N.I. user newsgroups.
    > I am writing a control program in Visual C++(console) on Win98 (by N.I.
    GPIB-TNT
    > board).
    > I need to control two devices one is Laser interferometer for measurement,
    > another is PZT(piezo actuator).
    > When I execute a simple read and write program,
    > it always shows " can not read ".
    > I am so confused.
    > Can you help me to overcome this problem?
    > And show me a new simple program!
    > Thank you very much.....
    >
    > I am so appreciate for your help.
    >
    > best regards
    > Andrew
    >
    > Ps.what is singlethreaded and multithreaded?

  • AT-GPIB/TNT board driver with linux kernel 2.2.16

    I have installed AT-GPIB/TNT board to my linux computer. I downloaded the driver 0.5.1 from ni web site, installed with no problem.
    First I used Window98 OS to test my hardware setup. My GPIB board is connect HP E3632A DC Power supply. I can use window version's ibic to run ibfind, ibdev, ibwrt, ibrd. Then I booted to linux, load the drive. But when I run ibwrt, give "EBUS" error. I used small test program to verify that I would get the same error. But I couldn't get it from Windows.
    Where is my problem? inside the driver? or linux driver setup?
    Thank you in advance
    Allyson

    Version 0.6 of the BETA driver is available at:
    http://www.ni.com/linux
    See if this new release gives you better performance
    Ryan Mosley

  • Dual channel receiver works with NI-PC2/driver v2.6 but not NI-GPIB/TNT(PNP)/driver v2.7.2

    I posted a message earlier but didn't word it correctly. We have a Microdyne 2800 receiver that we would like to set up remotely via 488. The receiver works fine in DOS using an older NI-PC2 card with the v2.6 drivers that came with it. However, when we switch to the newer PC-GPIB/TNT(PNP) 488 card with the latest DOS drivers, v2.7.2, it doesn't respond. The receiver recognizes that it received something via the bus but does nothing (it has a little red light that turns on when in remote mode). What prompted us to test it in DOS was that the same thing was happening under WinNT 4.0 using the PNP card and the v1.60 drivers.
    In ibic, I'm using the exact same
    sequence of commands to setup the card (ibdev, ibclr, and then ibln) and then I use the ibwrt to write the setup string to it. Are there any differences in the cards and/or drivers that I should be aware of?
    Thanks for any help!

    Dear Sr.,
    This kind of troubleshooting can be extensive so I recommend you to call us in Technical Support to address your issue, you can find the information at:
    http://sine.ni.com/apps/we/niae_asc.main
    Some of the common questions I'd ask you about this will be:
    1. Has this board work before?
    2. Have you tried it in another computer?
    3. When installing the board, did you ran the configuration utility and did the query and scan for instruments? (Start > Programs > National Instruments > NI-488.2 > Explore GPIB.... click F5 to Refresh then Select your board from "Devices and Interfaces" and click "Scan for Instruments" then when it finds your instrument click "Communicate with Instrument" and then click "Query")
    4. Have you tried this IBIC procedure? http://www.ni.com/su
    pport/gpib/max/ibic.htm
    5. Take a look at this link, it may be of help: http://www.ni.com/support/gpib/dos/attntpnp/default.htm
    6. What type of termination character does your instrument uses?
    If after looking at this questions and links your board still is not working please give us a call, we may need to try different workarounds or need more information from your system. As far as the information you wrote your board should work fine. Also, I can assume from your info that you have a 488.2 compatible instrument, is this correct?
    Regards,
    Nestor Sanchez
    Applications Engineering
    National Instruments
    Nestor
    National Instruments

  • AT-GPIB/TNT PnP and Sound Blaster 16 Clashing

    Hi Group
    The Story is:
    I have had a AT-GPIB/TNT PnP on a old Pentium 75/Win 95 Machine doing some testing, and havn't had a problem with it.
    I now wanted to install a Creative Sound Blaster (Vibra) 16, also PnP ISA, card for basic audio analysis measurements.
    The problem is when the Sound Blaster card is installed the PnP BIOS doesn't recognise the GPIB card at all, even with PnP
    disabled.
    Has anybody seen this before?
    Could it be that the PC can only handle 2 ISA PnP cards (there is also a PnP network card)?
    Would I be better of with a PCI SB card.
    Any help would be gratefull
    Tim S

    Tim,
    I had similar struggles with a 1995 vintage Pentium. My ISA GPIB conflicted with PCI sound card and PCI network card. It
    tooks me hours to hit upon a sequence of installing the cards, and manually locking in the resources, in order to get them all
    working.
    Some general suggestions: get back to a configuration that works, say without the sound card. Make note of the resources for
    the network card and GPIB card. While your there, examine the other possibilities. You can select other GPIB resource
    configurations and see what the I/O range, INT and DMA settings would be. For example, some GPIB resource configurations
    don't use INT and DMA at all. Write all of this down.
    Then install the sound card, without the GPIB. See what resources it wants, and explore what other configurations it might be
    happy with. Sound cards are tricky, because they usually use a lot of resources because they have a lot of functions: wave,
    midi, mixer, etc. Some also have "legacy drivers" that mimic the older DOS based sound cards, for backwards compatibility
    with games. You may be able to install the sound card and then remove some of these "extra drivers."
    With sound card working, and the network card working, reinstall the NI488 software. Then power down and install the GPIB
    card. Reboot. You may get lucky and everything just works.
    More likely, the GPIB will work and the sound card won't. Go check the GPIB card resources and you'll probably see that the
    NI488 drivers snagged one or more of the INT or DMA channels that the sound card was using. Try a different GPIB
    configuration, or manually edit the DMA and INT settings to NONE. Also check for I/O range conflicts. (Consult your written
    list, because the conflicts won't show in Device Manger -- since the sound card's not working it's not using any resources!)
    Hopefully, by telling Device Manager to NOT use Automatic Settings, you can get the GPIB working and still leave enough
    resources available for the sound card. Which you will probably have to go back and reinstall, from scratch. Possibly a few
    times before you get everything to fit.
    How bad do you want that sound card ? :~)
    Isn't (Microsoft) plug and play wonderful?
    p.s. you might also consider using CMOS setup to disable any motherboard resources you are not using, for example a COM port
    that's not connected to anything. Remember to write down EVERYTHING, you do so you can put it back if you have to.
    Good luck!
    Best Regards,
    Mike T
    Mike Tranchemontagne
    Consulting Applications Engineer
    TeraComm, Inc.
    148 Main Street
    Building A, 3rd Floor
    North Andover, MA 01845
    877-900-TERA (8372)
    978-557-9490 (FAX)
    603-598-4773 (Direct Line and Cell)
    Timothy John Streeter wrote:
    > Hi Group
    >
    > The Story is:
    > I have had a AT-GPIB/TNT PnP on a old Pentium 75/Win 95 Machine doing some testing, and havn't had a problem with it.
    > I now wanted to install a Creative Sound Blaster (Vibra) 16, also PnP ISA, card for basic audio analysis measurements.
    > The problem is when the Sound Blaster card is installed the PnP BIOS doesn't recognise the GPIB card at all, even with PnP
    > disabled.
    >
    > Has anybody seen this before?
    > Could it be that the PC can only handle 2 ISA PnP cards (there is also a PnP network card)?
    > Would I be better of with a PCI SB card.
    >
    > Any help would be gratefull
    >
    > Tim S
    Attachments:
    miket.vcf ‏1 KB

  • I have problems with pci-gpib card under windows me, What I need to know what to do in order to fix this problems?

    Hi, I have installed a pci-gpib card in my computer, I have a problem with
    installation, the message of troubleshooting wizard is as follow:
    "One or more missing GPIB interfaces.
    There are several reasons why you might encounter this problem:
    Reason: Your GPIB interface is incorrectly installed.
    Solution: Please verify that your GPIB interface is correctly installed
    and rerun the NI-488.2 Troubleshooting Wizard.
    Reason: You are using a non-Plug-and-Play interface (e.g., AT-GPIB/TNT,
    GPIB-PCII/IIA, GPIB-ENET) and you did not use the Add New Hardware Wizard
    to add the interface to your system properly.
    Solution: Click th
    e Add Hardware button and the Add GPIB Hardware wizard
    will guide you through the process of adding GPIB hardware.
    Reason: For the GPIB-USB and GPIB-1394, the host controller (USB or 1394)
    must be working properly in order to use the GPIB interface.
    Solution: Click on the System Details button for details about the USB and
    1394 host controllers.
    Reason: For the PCMCIA-GPIB and PCMCIA-GPIB+, the PCMCIA host controller
    must be working properly in order to use the GPIB interface.
    Solution: Use the Windows Device Manager to verify that your PCMCIA host
    controller is functioning correctly. Start the control panel by selecting
    "Start>>Settings>>Control Panel", open the System icon and select the
    Device Manager page. If you select "View devices by type", you can look at
    the PCMCIA socket properties to ensure it is correctly enabled."
    And on system details the message is the next:
    "USB Driver type: USB universal host controller"
    "This version of windows does not su
    pport IEEE 1394."
    I am using Windows Me, so i want to know what i need to do to fix this
    problems.
    Best regards.

    If you have a PCI-GPIB card, you needn't worry about the USB port or whether or not Windows ME supports 1394. All you need in NI-488.2 version 1.70 from National Instruments. Install this driver and then insert your card. Windows should detect the card and find the proper driver.
    If this did not happen in the proper sequence, look in the device manager and see if the card was installed as an "other device". If this happens, remove the card in the device manager and have windows redetect it. If this is not a solution, you may consider the ask an engineer page at www.ni.com/ask. Provide as many details as possible.

  • Instrument not recognized - computer too fast for AT-GPIB/TNT board

    I have a problem with a potentiostat (PAR 283) connected to ISA AT-GPIB/TNT (not pnp) board. I recently upgraded to a motherboard with 1.8GHz AMD processor. Potentiostat is recognized by other software as "28PD", "28PE" or sometimes just some garbage characters, instead of "283". I'm using driver version 1.6 (1.7 could not recognize the board). In "Measurement&Automation" potentiostat doesn't respond to *IDN? query (error EAB0). FRA analyzer connected to the same board is recognized without a problem. None of the Windows programs can control potentiostat (it's not recognized as "283). One DOS program, however, is able to recognize and control the potentiostat. I tested the whole system with 166MHz compu
    ter, and everything worked fine.
    My operating system is Win98
    Does anyone have idea what could solve the problem?
    Thanks
    Darko

    I don't necessarily have an answer to your problem, but I want to assure you those usually these problems are with the instrument. The IEEE 488.1 standard defines a 3-wire interlocked handshake to prevent any problems due to computer/device speeds.
    However, some devices violate this protocol. They rely on internal timing to determine when things should occur on the bus. For example, the talker asserts the DAV hardware line to indicate that data is valid on the bus. Following that, the listener is supposed to latch the data from the bus and then assert NDAC to indicate that it has taken the data from the bus. At the moment that NDAC has been asserted, the talker is allowed to modify the data lines since they have already been latched. However, some devices have noted in the past that their is usually X amount of time that passes from when NDAC is asserted until the data is removed from the wire. In order to improve peformance, they actually assert NDAC sometime before the data has been latched, assuming that the data will be there when they are actually ready to receive this data. In the case of moving to a faster computer, this data is actually staying on the bus for a shorter period of time than expected and the device receives garbage data.
    A similar phenomenon can occur when the device is the talker where is violates the proper 3-wire handshake.
    Note that not all failures are intential on the side of the device, it could be a legitimate bug.
    Now that I have given a somewhat long-winded description of how problems like this can manifest, I can give you a few recommendations.
    1) Obtain a GPIB bus analyzer and examine the handshake sequence to determine where the failure is.
    2) Talk to the equipment manufacturer to see if they have any updates
    3) Modify the bus timing in NI-488.2 from 500ns to 2ms. This is not likely to work since you are on the receiving end.
    4) Try to procure a GPIB-PCII/IIA board. This is a slower board that overall responds to handshaking slower than the AT-GPIB/TNT board and may mask the problem.
    5) Increase your cable length (including to "illegal" lengths such as 8m). This can add propegation delays that can mask this problem. I have seen work in teh past with troubled instruments.
    Good luck.

  • GPIB/TNT PnP DOS Installation Issue

    I have a AT-GPIB/TNT PnP board that I am trying to install on a DOS computer.  I am using the latest NI488.2 software for DOS.
    On bootup, the GPIB software drivers install properly, but the interface cannot be found.  When I run ibdiag it detects the correct board but then I get errors saying :
    1. Make sure the GPIB cables are disconnected.
    2. The base address does not match the address in the ni-pnp.ini file. 
    3. Another board or device is using the same address space. Try using a different I/O address and run the hardware diagnostic program.
    I don't have any cables connected ot the card.  The base address (as set using ibconf.exe) does match the address settings in the ni-pnp.ini file.  I have tried every possible base address with the IRQ and DMA turned off just to make sure that these were not in conflict.  I have tried other ISA slots in the computer.  I have disabled other on-board devices in the BIOS to prevent potential conflicts.  I have a PCI IO board also in the system.  But I have tried changing the addresses with and without this board installed.
    Based on the errors, it feels like the address settings may not be making it to the card properly, so that there is an address mismatch between what the computer/driver thinks is installed and what the card thinks it's address actually is.
    Any ideas?

    Jesse,
    Thanks for the reply.  
    I followed one of the links and read the following (I highlighted the critical portions in bold/underline):
    If ibdiag completes with no errors, your hardware is functioning properly. If ibdiag returns an error message, go back to the previous step and reconfigure the board to not use a DMA channel or an IRQ. Then shut down the computer, remove the IRQ, DACK, and DRQ jumpers, and boot up again. Rerun the hardware diagnostic test. At this point only the board's base I/O address is being tested. If the diagnostic continues to fail, then there are only three possible reasons:
    The Base I/O Address selected has a conflict with another hardware component in your computer. You should try other addresses, being certain to modify the DIP switches and ibconf settings each time.
    The Base I/O Address selected in ibconf is not a legal address. If using a Non-Plug and Play board, the Base I/O Address selected in ibconf does not match the DIP switch settings on the board. Sometimes users accidentally set the switches exactly opposite of what they should be. Be certain that you are following the switch diagram given in ibconf correctly.
    Note: The AT-GPIB/TNT (PnP) and AT-GPIB/TNT+ have valid address ranges of 0x0100 to 0x03E0 in increments of 0x20 bytes.
    The board has been damaged and needs repair. Call National Instruments if you feel this is the case.
    I worked the drill as described and I believe that the hardware is not working properly.  I will call NI.
    Thanks again.

  • Device Manager lists AT-GPIB/TNT instead of AT-GPIB

    I installed the AT-GPIB using the Atwin271 file, and then followed up with the Compatibility Release. The hardware and software diagnostics both succeed, and MAX is able to talk to the device.
    In the Device Manager, though, it lists the AT-GPIB/TNT as the device in use, and it has an exclamation point indicating an error/issue with the driver. As well, the resources also list AT-GPIB/TNT and have an exclamation over the listing icon.
    When I "add new hardware" and choose the GPIB device, the AT-GPIB is not listed there. AT-GPIB/TNT is, and the rest of the devices include various other GPIB products that are not similar (including STD-GPIB, etc...).
    Should the AT-GPIB be listed, or is this the reason the Compati
    bility Release was used? ie: one possible understanding I can come up with is that the drivers I installed for the card are in fact for the AT-GPIB/TNT, and then the addition of the Compat. Release is used to allow the drivers for the /TNT to work with the plain AT-GPIB.

    From your follow-up, you have seen the http://www.ni.com/support/gpib/ win98_95cr.htm page. On that pages is a manual link: "Using Your NI-488.2 Software for DOS or Windows 3 with Windows 98/95 Manual." Follow the directions within this manual for information.
    Your driver is correct. The AT-GPIB will not show up in the device manager. If you added it to the device manager (as an AT-GPIB/TNT), you may have multiple NI-488.2 drivers installed (one for 32-bit windows such as 1.7 or 2.2) and the one for Windows 3.x (2.7.1). I highly recommend uninstalling the 32-bit version if it is installed (should be able to do this through add/remove programs).
    If you have specific problems following the instructions, post a follow up and we can try to help.

  • Problems with pci--gpib-300k from computerboards

    hallo,
    i have problems with my gpib-card, win95 and 2000 identify this card
    corectly but labview not, the max 2.0 find not cards.......have everyone the
    self card and can help????
    (sorry for my bad english..)
    bye & thanks...
    Thomas

    Thomas,
    The short answer is the MAX will not recognize non-NI devices. NI-MAX was designed to recognize and interface with National Instruments' boards such as our PCI-GPIB, AT-GPIB/TNT, etc. With the introduction of MAX2.0 and NI-VISA2.5, there was an added capability to recognize some Hewlett-Packard boards but even then, configuration of them must be done from an HP interface.
    LabVIEW will interface with the board fine but MAX is designed specifically to interface with our drivers for our boards.
    Ryan Mosley
    National Instruments, Applications Engineer
    http://www.ni.com/exchange

  • A problem regarding set up of Oracle Lite 3.6.0.2.0 on Win 95, with JDK 1.1.8 &java 2

    A problem regarding set up of Oracle Lite 3.6.0.2.0 on Win 95, with JDK 1.1.8 and Java 2 SDK ( Ver 1.3 Beta)
    After the installation of Oracle Lite 3.6.0.2.0 on a laptop (with WIN 95 OS), When I run Oracle Lite Designer from start menu, I receive following error message :
    ====================================
    Invalid class name 'FILES\ORA95_2\LITE\DESIGNER\oldes.jar;C:\PROGRAM'
    usage: java [-options] class
    where options include:
    -help print out this message
    -version print out the build version
    -v -verbose turn on verbose mode
    -debug enable remote JAVA debugging
    -noasyncgc don't allow asynchronous garbage collection
    -verbosegc print a message when garbage collection occurs
    -noclassgc disable class garbage collection
    -ss<number> set the maximum native stack size for any thread
    -oss<number> set the maximum Java stack size for any thread
    -ms<number> set the initial Java heap size
    -mx<number> set the maximum Java heap size
    -classpath <directories separated by semicolons>
    list directories in which to look for classes
    -prof[:<file>] output profiling data to .\java.prof or .\<file>
    -verify verify all classes when read in
    -verifyremote verify classes read in over the network [default]
    -noverify do not verify any class
    -nojit disable JIT compiler
    Please make sure that JDK 1.1.4 (or greater) is installed in your machine and CLASSPATH is set properly. JAVA.EXE must be in the PATH.
    ====================================
    My ORACLE_HOME is c:\program files\ora95_2 and Oracle Lite is installed under the ORACLE_HOME in LITE\DESIGNER directory.
    JDK version is 1.1.8 which is greater than 1.1.4 installed in c:\program files\jdk1.1.8, My PATH, and CLASSPATH are set in AUTOEXEC.BAT as follows:
    set CLASSPATH=c:\Progra~1\jdk1.1.8\lib\classes.zip;c:\progra~1\ora95_2\lite\classes\olite36.jar;c:\progra~1\ora95_2\lite\designer\oldes.jar;c:\progra~1\ora95_2\lite\designer\swingall.j ar
    PATH=C:\Progra~1\Ora95_2\bin;.;c:\Progra~1\jdk1.1.8\lib;c:\Progra~1\jdk1.1.8\bin;C:\Progra~1\Ora95_2\lite\Designer;C:\WIN95;C:\WIN95\COMMAND;C:\UTIL
    And, I can run JAVA.EXE from any directory on command prompt.
    With JAVA 2 SDK (ver 1.3 Beta) instead of JDK 1.1.8 I'm getting a different Error message as follows:
    =============================
    java.lang.NoClassFoundError: 'FILES\ORA95_2\LITE\DESIGNER\oldes.jar;C:\PROGRAM'
    Please make sure that JDK 1.1.4 (or greater) is installed in your machine and CLASSPATH is set properly. JAVA.EXE must be in the PATH.
    ==============================
    the PATH and CLASSPATH were set accordingly, as with JDK1.1.8, and there was no classes.zip in classpath
    also the class file or the jar file looks weird or wrapped in the error message : 'FILES\ORA95_2\LITE\DESIGNER\oldes.jar;C:\PROGRAM'
    Another interesting thing I noticed is if I run oldes.exe from Installation CD, the Oracle Lite Designer runs fine, and without error, I'm able to modify tables in the database of my laptop also.
    Could someone shade some light on what am I doing wrong here ?
    Thanks for help in advance .
    Regards
    Viral
    null

    On 07/20/2015 06:35 AM, Itzhak Hovav wrote:
    > hi
    > [snip]
    > [root@p22 eclipse]# cat eclipse.ini -startup
    > plugins/org.eclipse.equinox.launcher_1.3.0.v20120522-1813.jar
    > --launcher.library
    > plugins/org.eclipse.equinox.launcher.gtk.linux.x86_64_1.1.200.v20120913-144807
    >
    > -showsplash
    > org.eclipse.platform
    > --launcher.XXMaxPermSize
    > 256m
    > --launcher.defaultAction
    > openFile
    > -vmargs
    > -Xms40m
    > -Xmx512m
    > [snip]
    Try this: http://wiki.eclipse.org/Eclipse.ini. You should have read the
    sticky posts at forum's top for getting started help.

  • When i try to open the itunes store in itunes,windows closes it after not finding a solution for the problem.I have uninstalled and reinstalled the Itunes software. I am running Win 7-with IE10-any help?

    When I selected the Itunes store on my win PC today-the program was closed by windows with windows saying there was a problem. I tried a couple of times and then uninstalled the itunes software and reinstalled it with the same results. The program has always worked before but I have not used it recently since the Ipad now receives it's software updates right off the router. I am running Win 7 with IE10. Anyone with the same problem?

    My post has been viewed 24 times, and yet have had no answers. I have always like adobe products, however if this is the type of support they offer, I will never purchase another product of theirs. The issue I am having is the same issue many others have had, and yet no answer. Poor customer service!

  • AT-GPIB/TNT AND Windows NT4 Install Problems

    When I install my AT-GPIB/TNT card on a WinNT4 sp6 PC, it always fails the trouble shooting wizard. The wizard indicates a DMA conflict, but NT Diagnostics doesn't indicate any conflicts. All other available DMAs are consumed. Short of installing a PCI-GPIB card, how best can I resolve this issue. Note, GPIB communications will not work unless the GPIB card passes the trouble shooting wizard.
    The odd thing is that it had worked previously...

    What is the GPIB driver version that you have? I hope you have the latest GPIB driver available from http://www.ni.com/support/gpib/versions.htm.
    I would recommend that you un-install the driver remove the card and follow the steps from www.ni.com/support/install. Also in the bios settings for NT the PNP option should be set to NO.

  • Steps to use win 7 with bootcamp on imac7,1

    what steps do I need to do to utilize win 7 with boot camp on my imac7,1 ?

    http://manuals.info.apple.com/MANUALS/1000/MA1519/en_US/Boot_Camp_Install-Setup_ 10.6.pdf

  • Flash Player 11.6.602.180 installed on Win 7 with IE and can never play videos from

    Hi, I installed Flash Player 11.6.602.180 installed on Win 7 with IE and can never play videos from this site http://w3.newsmax.com/newsletters/uwr/video_hyman.cfm?s=al&promo_code=12CF6-1
    any idea what this site is looking for ? thanks bill m

    What do you see instead of the expected Flash content?

Maybe you are looking for