C240 M3 with VIC 1225 managed with UCSM: Failure Reason: not enough vNIC available

Hello,
I have problems in creating a working service profile with more than one vNIC/NIC.
I have a shiny new C240 server with a UCS VIC 1225 network card in PCI Slot 2. The server is directly connected to the two Fabric Interconnects (6248UP). 2 Direct attached cables with no FEX ("Direct Connect Mode Cluster Setup"). Firmware version is 2.2(1d). After setting the FI port to server role the server is flawlessly discovered. And shows up in the UCSM-GUI. And I see the VIC 1225 adapter that has 2 DCE Interfaces.
Now, when I try to create Service Profile for this server by choosing "Hardware Based Service Profile" (with Create default vNICs [X] and Create Default vHBA [ ]) I get the following error:
I am able to create a working profile with one vNIC in one fabric, but a soon as I try to add a second vNIC I get the error above.
What I expected was, that it is possible to map more than one vNIC/NIC into the server profile. At leat 2 NICs, one in each fabric.
I would be great if there is someone to bring some light in the darkness thats around me. Any hints or pointers to obvious documentation would be great.
Kind regards,

Hello,
thanks for your answer. And you are probably correct.
I can add aditional vnics to fabric A but not to fabric B. And even trying to add a single nic to Fabric B does not work.
I changed the ports for this server on the fabric interconnects and rebooted the FI but it did not help.
When I look at the General Tab of my server and then on Connection Details I see:
Conection Path: A, B
Connection Status: A
Managing Instance: A
My conclusion is, I have a problem with the Connection Path B of my C240..

Similar Messages

  • C460-M2 with 2 VIC-1225, managed by UCSM

    C460-M2 with 2 VIC-1225; all documents show only one VIC-1225 (which has to be in PCI slot nr.1)  single wire managment with a UCS FI ?
    Is this a limitation ? or must the second VIC-1225 be connected to a switch outside the FI ?
    Walter.

    I received the following answer
    Good question Walter. The documentation is confusing. If running the C460 as part of a UCS integration, only 1 card is supported.Although the server supports 2 cards , slot 1 & 2 according to the specsheet. The datasheet states that upto 3 VIC can be supoprted int he server.
    The Cisco CCW config tool allows you to configure 2 VIC1225 in the C460.
    From the 460 spechseet.
    http://www.cisco.com/en/US/prod/collateral/ps10265/ps10493/ps11587/spec_sheet_c17-662220.pdf
    Page 24
    The C460 server accommodates the Cisco 1225 Virtual Interface card, which is supported only in slots 1 and 2. Note, however, that if the server is running UCSM, only slot 1 is supported for the VIC card.
    ■ The Cisco Card NIC mode is currently supported only with a Cisco 1225 VIC (UCSC-PCIE-CSC-02) that is installed in PCIe slot 1.
    ■ The C460 server accommodates the Cisco 1225 Virtual Interface card, which is supported only in slots 1 and 2. Note, however, that if the server is running UCSM, only slot 1 is supported for the VIC card.
    From the datasheet
    http://www.cisco.com/en/US/prod/collateral/modules/ps10277/ps12571/data_sheet_c78-708295.html
    System Requirements
    The Cisco UCS VIC 1225 is designed for use only on Cisco UCS C-Series Rack Servers. A single Cisco UCS VIC 1225 is supported on Cisco UCS C260 M2, C460 M2, C220 M3, C240 M3, C22 M3, and C24 M3 rack servers. Up to three Cisco UCS VIC 1225 cards are supported on these servers depending on the slot configuration.
    Anyone at Cisco want to clarify the above?
    Message was edited by: NABIL YAGHI

  • UCS C420M3 server with VIC 1225 , Cant see LOM ethernet ports

    Hi Guyz,
    we have C420M3 server with VIC 1225 connected on PCIe slot, with Fabric Interconnet.
    After installing OS & drivers , vNICs created on VIC 1225 by service profile appear, but 4 gig ports on Server LOM dont appear.
    Any Idea.?
    Thank

    If you integrate your rack server to UCSM, you will be able to use the LOM ports ONLY for Mgmt traffic, that is when you integrate the server in "Dual Wire Mode".
    There is no need (unless you have one for an special reason I am not considering in this very moment) to use the LOM ports once you have integrated the server, precisely cause the VIC 1225 is a not a regular NIC card, nor a regular HBA, it is actually a CNA (Converged Network Adapter) which basically lets you do in one card, what you would do with two (meaning "what you would do with a separate NIC and HBA")
    When you have a VIC card, you actually have the option to create up to 256 virtual interfaces (that's the capability of the hardware, always limited by the OS used, please keep that in mind), that is the reason why, after the server is integrated, you totally depend on the interfaces set in the Service Profile instead of the physical interfaces.
    Find more info here:
    http://www.cisco.com/c/en/us/products/interfaces-modules/unified-computing-system-adapters/models-comparison.html
    Do you have a particular reason for using the LOM ports instead of creating 2 additional virtual interfaces in the Server's Service Profile?
    -Kenny

  • Cisco UCS C220 with VIC 1225

    Hello,
    We have Cisco UCS C220 M3 with VIC 1225 card installed. We connected only one 10G port of VIC 1225 to Nexus 5548UP switch. But I do not see this port on switch and in CIMI the status for this port shows Link Down. I wanted to to iSCSI boot from storage NetApp FAS2240 but since I don't see this port on my Nexus switch I am unable to do boot from NetApp. I tried both ports on VIC 1225 with same result. Please I need help in this matter. I know I am missing something very simple but can't figure this out.
    Thanks,
    Salman

    Hi Kenny,
    Here is the answers:
    -What slot is this card installed in?
    Mezzenine
    -How many CPUs does the server have installed? (1 OR 2 CPUs can make the difference)
    2x 2.90 GHz E5-2690/135W 8C/20MB Cache/DDR3 1600MHz
    -Is the PCIe slot enabled in BIOS? << Let us know if you don't know how to check it from CIMC
    I believe I did. Server>BIOS>BIOS advanced> PCIe (Let me know if this correct)
    -Have you confirmed that the cable is good?
    I have changed four cables. I am using SFP-H10GB-CU2M= Twinax cable.
    -If the switch does not even see the port and CIMC says it is down, have you confirmed the switch port is properly configured?
    CIMI says “Link Down” in VIC adapter General area. The switch interface config has only “switchport mode access” in default vlan 1.
    -What is the firmware running on the server and the OS?
    We upgraded the firmware with latest ucs-c220-huu-1.5.4-3.iso.
    Let me share with you the complete BoM of the server:
    UCSC-C220-M3S              1x  UCS C220 M3 SFF w/o CPU  mem  HDD  PCIe  PSU  w/ rail kit
    UCS-CPU-E5-2690              2x  2.90 GHz E5-2690/135W 8C/20MB Cache/DDR3 1600MHz
    UCS-MR-1X082RY-A    16x 8GB DDR3-1600-MHz RDIMM/PC3-12800/dual rank/1.35v
    CAB-9K10A-UK              2x  Power Cord 250VAC 10A BS1363 Plug (13 A fuse) UK
    UCSC-PCIE-CSC-02    1x           Cisco VIC 1225 Dual Port 10Gb SFP+ CNA
    UCSC-PCIE-QSFP              1x  Qlogic QLE8242-CU Dual Port 10 GbE FCoE CNA
    UCSC-HS-C220M3              2x  Heat Sink for UCS C220 M3 Rack Server
    UCSC-RAIL1              1x  Rail Kit for C220 C22 C24 rack servers

  • C240 M3 with VIC 1225 VMware network issue

    Just got my hands on a few C240 M3′s with the VIC 1225 adapter and began setting them up as a VMware 5.1 U1 cluster. I’ve configured 8 vNICs per host: 2 for Management, 2 for VMotion, 2 for iSCSI, and 2 for VM traffic. Each pair of vNICs has one pinned to uplink 0 and the other to uplink 1. vNICs are set to trunk mode in the VIC since I am tagging multiple VLANs from VMware. The hosts are physically connected to a stacked pair of Cisco 4500-X switches; physical uplink 0 to one switch, uplink 1 to the other switch. Switch ports are trunked to allow the VLANs we plan to use. Portfast is enabled. VMware vSwitches using Source Port ID for Load Balancing and the vNICs are active/active for Management and VM traffic. No port channel or Etherchannel is configured on the swtiches.
    After creating a VM for vCenter and joining the hosts to it, I started migrating existing VMs from an old cluster and saw odd network behavior. It seems whenever a VM or vmkernel interface are on any vNIC pinned to the same physical uplink on the same host, they can’t talk to each other.
    Example: VM1 and VM2 are on host 1. VM1′s network adapter is pinned to vNIC1 using VLAN 10 which uses physical uplink 0. VM2′s network adapter is pinned to vNIC2 using VLAN 10 which uses physical uplink 1. VM1 and VM2 can ping each other. If I move VM2′s network adapter to any vNIC that uses physical uplink 0, just like VM1, then VM1 and VM2 can no longer ping each other. Or if host 1′s management IP is pinned to vNIC 1 on physical uplink 0, any VM on host 1 using a vNIC also pinned to physical uplink 0 cannot ping the host.
    Anyone have any ideas?  Is something configured incorrectly on the switch?  On the VIC?
    Thanks!

    Hello Michael,
    I assume VIC is operating Classical Ethernet ( CE ) mode and VM1 and VM2 are in different vswitchs for the non-working scenario, ( where there vNICs used by vSwitch are pinned to physical uplink ) .
    If this is the scenario, the frames have to be switched upstream switch and needs to be forwarded back on the same switch interface. Any IEEE standards based switch will not forward such traffic flow.
    You might want to take advantage of Adapter-FEX or adapt changes to design to accommodate such traffic flows.
    HTH
    Padma

  • C240 with VIC 1225 : enable Failover

    Hi,
    I have a C240M3 with a VIC 1225. I would want to enable failover.
    In order that, i have to enable NIV mode. But it seems to me that i could not.
    Why ????
    how to solve this issue ???
    C240-FCH1749V0VC /chassis/adapter # set
    cli         CLI options
    description Adapter description
    fip-mode     Enable/disable FIP
    vntag-mode   Enable/disable VNTAG
    niv-mode not present.....
    C240-FCH1749V0VC /chassis # show adapter 2 detail
    PCI Slot 2:
       Product Name: UCS VIC 1225
       Serial Number: FCH17457ESH
       Product ID: UCSC-PCIE-CSC-02
       Adapter Hardware Revision: 6
       Current FW Version: 2.1(3a)
       VNTAG: Disabled
       FIP: Enabled
       Configuration Pending: no
       CIMC Management Enabled : yes
       VID: V03
       Vendor: Cisco Systems Inc
       Description:
       Bootloader Version: 2.1(3a)
       FW Image 1 Version: 2.1(3a)
       FW Image 1 State: RUNNING ACTIVATED
       FW Image 2 Version: 2.1(3a)
       FW Image 2 State: BACKUP INACTIVATED
       FW Update Status: Idle
       FW Update Error: No error
       FW Update Stage: No operation (0%)
       FW Update Overall Progress: 0%
    C240-FCH1749V0VC /chassis #
    any detail on NIV
    My C240 is connect to Catalyst 3750.
    Many thx.
    Nicolas.

    Hello Kenny,
    My main question is « how to use and to configure failover on VIC 1225 ». I have already configure failover on B-serie but never on c-series
    For more details (please see diagram in attach), my issue is that my C240 on DRP site (just 40 metres from main site) is connected to local switch (C3560) and to LAN core (C4506 on main site). This connection on 2 Catalyst devices seems to be a problem for vSphere :
    i could see that : as soon as I connect the 2 ports, C240 lost connection to vCenter ; CIMC is still pinging.
    I could read on ucsguru forum, someone has the same issue with 2 catalyst.
    I do not have a lot of time for this deployment and installation. So, I told me to use actif/passif should be the faster way. If I connect only a cable (by shuting/ no shuting an interface on a catalyst), it works. In order to do that, automatically, I would want to implement failover on VIC1225
    Any suggestion on my issue is welcome.
    Many thanks.
    Nicolas.

  • Registry issue with Lenovo Power Manager with X61

    I have the following problem. 
    Hi guys,
    Lenovo power manager v1,6 quit working properly lately so I googled for a solution which involved removing power schemes which had reproduced in the registry to cause an overload to the application.
    Anyway because this wasnt really working (I ended up with having powerschemes but wasnt allowed to change them) I in my brightest moments decieded to delete the messed up part of my registry [HKEY_CURREN_USER --> Control panel --> PoweCfg] because it was preventing my reinstalations of said program from functioning properly since they resorted to the previosly present registryentrys.
    Well it appears that when installing the powermanager it does not write these new registry entrys and Im stuck now without a way to get them back. I wonder at what point that registry entry is written in the first place, does anyone feel like exporting said part of their healthy registry...please...?

    ..this one is from an x200 with Server2003...seems like you're familiar enough with registry exports and wrapping and shoiuld be able to convert this into a *.reg form:
    Windows Registry Editor Version 5.00
    [HKEY_USERS\.DEFAULT\Control Panel\PowerCfg]
    "CurrentPowerPolicy"="7"
    [HKEY_USERS\.DEFAULT\Control Panel\PowerCfg\GlobalPowerPolicy]
    "Policies"=hex:01,00,00,00,00,00,00,00,03,00,00,00​,08,00,00,00,00,00,00,00,03,\
      00,00,00,08,00,00,00,02,00,00,00,03,00,00,00,00,00​,00,00,02,00,00,00,03,00,\
      00,00,00,00,00,00,00,00,00,00,01,00,00,00,00,00,00​,80,00,00,00,00,01,00,00,\
      00,00,00,00,80,01,00,00,00,05,00,00,00,02,00,00,00​,04,00,00,c0,01,00,00,00,\
      04,00,00,00,01,00,00,00,0a,00,00,00,00,00,00,00,03​,00,00,00,01,00,01,00,01,\
      00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00​,00,00,00,00,02,00,00,00,\
      00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00​,00,00,00,03,00,00,00,00,\
      00,17,00,00,00
    [HKEY_USERS\.DEFAULT\Control Panel\PowerCfg\PowerPolicies]
    [HKEY_USERS\.DEFAULT\Control Panel\PowerCfg\PowerPolicies\0]
    "Name"="Home/Office Desk"
    "Description"="This scheme is suited to most home or desktop computers that are left plugged in all the time."
    "Policies"=hex:01,00,00,00,02,00,00,00,01,00,00,00​,00,00,00,00,02,00,00,00,00,\
      00,00,00,00,00,00,00,00,00,00,00,2c,01,00,00,32,32​,00,03,04,00,00,00,04,00,\
      00,00,00,00,00,00,00,00,00,00,b0,04,00,00,2c,01,00​,00,00,00,00,00,58,02,00,\
      00,01,01,64,50,64,64,00,00
    [HKEY_USERS\.DEFAULT\Control Panel\PowerCfg\PowerPolicies\1]
    "Name"="Portable/Laptop"
    "Description"="This scheme is designed for extended battery life for portable computers on the road."
    "Policies"=hex:01,00,00,00,02,00,00,00,01,00,00,00​,00,00,00,00,02,00,00,00,01,\
      00,00,00,00,00,00,00,b0,04,00,00,84,03,00,00,32,32​,03,03,04,00,00,00,04,00,\
      00,00,01,00,00,00,14,f2,06,00,84,03,00,00,78,00,00​,00,08,07,00,00,2c,01,00,\
      00,01,01,64,64,64,64,a0,71
    [HKEY_USERS\.DEFAULT\Control Panel\PowerCfg\PowerPolicies\2]
    "Name"="Presentation"
    "Description"="This scheme keeps the monitor on for doing presentations."
    "Policies"=hex:01,00,00,00,02,00,00,00,01,00,00,00​,00,00,00,00,02,00,00,00,01,\
      00,00,00,00,00,00,00,00,00,00,00,84,03,00,00,32,32​,03,02,04,00,00,00,04,00,\
      00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,00​,00,00,00,00,00,2c,01,00,\
      00,01,01,50,50,64,64,00,00
    [HKEY_USERS\.DEFAULT\Control Panel\PowerCfg\PowerPolicies\3]
    "Name"="Always On"
    "Description"="This scheme keeps the computer running so that it can be accessed from the network.  Use this scheme if you do not have network wakeup hardware."
    "Policies"=hex:01,00,00,00,02,00,00,00,01,00,00,00​,00,00,00,00,02,00,00,00,00,\
      00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,32,32​,00,00,04,00,00,00,04,00,\
      00,00,00,00,00,00,00,00,00,00,b0,04,00,00,84,03,00​,00,00,00,00,00,08,07,00,\
      00,00,01,64,64,64,64,00,00
    [HKEY_USERS\.DEFAULT\Control Panel\PowerCfg\PowerPolicies\4]
    "Name"="Minimal Power Management"
    "Description"="This scheme keeps the computer on and optimizes it for high performance."
    "Policies"=hex:01,00,00,00,02,00,00,00,01,00,00,00​,00,00,00,00,02,00,00,00,00,\
      00,00,00,00,00,00,00,00,00,00,00,2c,01,00,00,32,32​,03,03,04,00,00,00,04,00,\
      00,00,00,00,00,00,00,00,00,00,84,03,00,00,2c,01,00​,00,00,00,00,00,84,03,00,\
      00,00,01,64,64,64,64,00,00
    [HKEY_USERS\.DEFAULT\Control Panel\PowerCfg\PowerPolicies\5]
    "Name"="Max Battery"
    "Description"="This scheme is extremely aggressive for saving power."
    "Policies"=hex:01,00,00,00,02,00,00,00,01,00,00,00​,00,00,00,00,02,00,00,00,05,\
      00,00,00,00,00,00,00,b0,04,00,00,78,00,00,00,32,32​,03,02,04,00,00,00,04,00,\
      00,00,00,00,00,00,00,00,00,00,84,03,00,00,3c,00,00​,00,00,00,00,00,b4,00,00,\
      00,01,01,64,32,64,64,00,00
    [HKEY_USERS\.DEFAULT\Control Panel\PowerCfg\PowerPolicies\7]
    "Policies"=hex:01,00,00,00,00,00,00,00,01,00,00,00​,00,00,00,00,00,00,00,00,00,\
      00,00,00,00,00,00,00,00,00,00,00,00,00,00,00,32,32​,00,00,04,00,00,00,04,00,\
      00,00,00,00,3d,77,2e,f2,07,00,00,00,00,00,00,00,00​,00,00,00,00,00,00,00,00,\
      00,01,01,64,50,64,64,91,7c
    Don't just sit there, take a second and use the Kudo's button to compliment the people who help you.

  • Issue with turning on project 2010 / 2013 - "There is not enough memory to complete the operation. To free up available memory, close programs, projects, or windows you aren't using, and then try again."

    I get the following error after the installation and configuration window of MS Project: "There is not enough memory to complete the operation. To free up available memory, close programs, projects, or windows you aren't using, and then try again."
    It happens both with MS Project 2010 and 2013 on a Windows 7 desktop. 
    I tried installing / uninstalling Office 2010, MS Project, tried installing 32 and then 64 bit versions, clean up, disk error checker, startup changes (msconfig), anti virus, running as Windows 7 and then Windows XP compatible mode. 
    Nothing helps. I see this issue reported as early as 2007 version of MS projects on Microsoft forums, but I do not see any solution anywhere. Any suggestions on how to fix the issue without having to reformat hard drive? Every other application, including
    all other Office programs work seamlessly. 
    I also tried Microsoft support, after an hour and a half of basically doing what I did before, I was told I have to pay 99$ for "premium" support, so someone can look at this bug. 
    I have 16 Gb RAM and more than 200Gb or hard drive free, so actual memory is not the problem. 

    This issue was originally reported with MS Project 2007 and keeps popping up since.
    A quick Google search provides more than 200K pages of results of this issue:
    https://www.google.ca/webhp?sourceid=chrome-instant&ion=1&espv=2&ie=UTF-8#q=There+is+not+enough+memory+to+complete+the+operation.+To+free+up+available+memory%2C+close+programs%2C+projects%2C+or+windows+you+aren't+using%2C+and+then+try+again.
    And 193K results on Bing:
    http://www.bing.com/search?q=There+is+not+enough+memory+to+complete+the+operation.+To+free+up+available+memory%2C+close+programs%2C+projects%2C+or+windows+you+aren%27t+using%2C+and+then+try+again.&go=Submit&qs=n&form=QBLH&pq=there+is+not+enough+memory+to+complete+the+operation.+to+free+up+available+memory%2C+close+programs%2C+projects%2C+or+windows+you+aren%27t+using%2C+and+then+try+again.&sc=0-0&sp=-1&sk=&cvid=4cb023c1fbd94ec2bba9821b095f21f2
    Computer was defragged already. I run more tests, and specifically when MS Projects tries to run, it tries to take all memory, more than 300Gb, on the computer. (DropBox was running at the same time, and warned that there were no space. As soon as MS Project
    stopped attempting to configure itself, everything came back to normal and the available space became available again.)
    Looking through older forum posts, looks like this application tries to take "unlimited" amount of memory. Some registry fixes are mentioned potentially, but I was not able to apply them. 
    Since everything else works, this is a MS Project bug reported by multiple users on various versions of Windows, including Vista and 7, so please provide a fix and not 'not a know bug' lie. All the premium support will say, is to format the hard drive, unless
    they have a patch or a registry edit solution. If the latter is true, since the issue exists for multiple years, it should have been already been provided to users.
    Also, I am not running a SQL server, or any server, this is an installation on a local machine. 

  • IPhoto 6 crashes when opening with iPhoto Library Manager with external sto

    I've had stored many iPhoto libraries on my Freecom Mobile Drive 160gb, accessing them via iPhoto Library Manager, for years. Suddenly, when I try to open a library, iPhoto crashes. I'm still able to go into the storage disk so I don't think this is damaged. I've also reinstalled IPLManager (using original 3.2.3), without any luck.
    I get this crash report (greatly abbreviated)
    PID: 809
    Thread: 0
    Exception: EXCBADACCESS (0x0001)
    Codes: KERNPROTECTIONFAILURE (0x0002) at 0x00000000
    Does this make sense to anyone? I can't understand why one minute everything is fine, and then the next a procedure which has worked for a long time, doesn't. BTW, I've taken off lots of junk from the Freecom external drive (have 44gb available) and 3gb available on my iBook.
    Many thanks in advance for any help or advice.

    That
    Exception Codes: KERNPROTECTIONFAILURE
    is always a Data Related issue.
    So use iPhoto Library Manager to rebuild the Library. This will create a new library based on data in the albumdata.xml file. Not everything will be brought over - no slideshows, books or calendars, for instance - but it should get all your albums and keywords back.
    Because this process creates an entirely new library and leaves your old one untouched, it is non-destructive, and if you're not happy with the results you can simply return to your old one.
    Regards
    TD

  • Itunes install on windows - not enough space with 80 gig open, itunes install on windows - not enough space with 80 gig open

    Hi
    had itunes installed (windows vista 64), after lots of errors and refusing to sync nor repair nor upgrade - I uninstalled. the next step was that it didnt want to reinstall due to older version... have now removed all with Revo uninstaller pro. Now i cant re install as it tells me I dont have enough space even though i have 80gig open? dont know what else to try.

    Best to remove all music and re-sync from the Mac, which you can do without doing a complete Restore of the iPhone.  Assuming that you auto-sync music and not manually manage music on the iPhone:
    While connected to your Mac iTunes, change your sync settings by un-checking the "Sync Music" option, then apply the change to delete all the music.
    Since there seems to be some funny business with iCloud, where some music downloads stubbornly remain on the iPhone despite attempts to delete them, disconnect from iTunes and check your iPhone to make sure all music really was removed.  If you still see music, first turn off the "Show All Music" option (Settings/Music/Show All Music/OFF) since songs with a cloud symbol really aren't on the device.  If after doing that you still see music on the iPhone, go to Settings/General/Usage/Music and swipe left to right across "All Music" and tap Delete.  Hopefully that deletes past cloud downloads you may have done.  If not, I've had to change to manual sync mode, manually deleting remaining songs by navigating into iPhone via iTunes, backing up, restoring from backup, then changing back to auto-sync mode.
    Re-connect back to iTunes and change your sync settings to allow music syncing -- either your entire library, or selected playlists, genres, albums, etc. 
    You mentioned that your library is "only 14 GB" but consider that if you have a 16 GB iPhone you don't really have 16 GB of storage, so perhaps you're running up against a real capacity issue if you own a 16 GB model, or have a larger model but other things taking up space.  So perhaps you can no longer sync your entire library as you expect.

  • I have tried to sync my Iphone with my current Itunes and for some reason not all of my music is transferring to my Iphone.  Some songs that were on my phone previously, are now not transferring.  Any ideas?

    I have downloaded all of the recent upgrades for both Itunes and Iphone.  Now for some reason, not all of my songs in my playlists are transferring when I sync.  Previously I have had the songs in the playlists on my phone, but now some of them are not there although they are listed and show in Itunes.  Any ideas?

    iTunes will only copy back iTunes purchased music. If you don't still have a copy of the music that you copied from CDs or bought from other stores anywhere (e.g. on another computer or on your backup of your library) then there are some third-party programs listed half-way this page which should be able to copy them back : Recover your iTunes library from your iPod or iOS device.

  • Placed order on Creative web, with VISA payment...... not enough for Creative

    i did place an order on creative onli've shop web site, using my VISA, but this is not enough. When ALL web sites are usually doing right a way, releasing the order, signing, giving VISA autorization,....... is not enough for Creative. They need much more!!!!!!!!!!!
    Copy (2 sides without numbers) of your credit card plus some other creasy information like copy of BANK last payment of your personel credit card.
    Trying to amange taht for 7 days now and still order not released
    Just ONE ADVISE........ DO NOT BUY DIRECT FROM CREATIVE WEB STORE........

    Just got email telling the order has been received
    Anyway, Creative web site is not well working and placing an order, giving credit card number is not enough for CREATIVE. I am used to buy from the WEB and never got request to give copy of credit card, ......
    CREATIVE should revise the way they accept oders, using credit card as payment and take model from all other web sites.
    My recomemndation is still the same. DO NOT PLACE ORDER ON CREATIVE DIRECT. if you want to get creative product (and I guess this is good product) go to some other CREATIVE's vendors. You will certainely get MUCH BETTER SERVICE

  • C460 Rack Server with two VIC 1225 - UCSM vNIC placement policy

    I am trying to integrate C460 having 2 VIC 1225 cards with UCSM. The objective is to have 2 ethernet interfaces assigned to each VIC , one per FI.
    vNIC 1 on VIC 1 - FI A failover to FI B
    vNIC 2 on VIC 1 - FI B failover to FI A
    vNIC 3 on VIC 2 - FI A failover to FI B
    vNIC 4 on VIC 2 - FI B failover to FI A
    I have created a service profile with 4 vNICs and assigned to C460. When the UCSM is configured to use the system default for vNIC/vHBA placement policy, all 4 vNICs are assigned to one VIC. When trying to place them manually with 2 on vCon1 and 2 on vCon2, I am seeing insufficient resource error. Both the VIC are recognized and UCSM server tab shows both of them as adapters.
    Could someone please let me know how to achieve it?
    Thanks!

    The C460 has an integrated BCM 57711 which would also be recognized by the system.  What's most likely happening is that the VIC 1225s are on vCon1 and vCon3 and the BCM card is on vCon2, since FF is not supported on the Broadcom adapter this would cause the association to fail.  Try placing the manual placement with vCon1 and vCon3 and see if this clears up the issue.
    Steve McQuerry
    UCS - Technical Marketing

  • Posting to G/L accounts with open item management not permitted Fagl_post

    Dear Expert,
    When i run the foreign cur rev. through FAGL_FC_VAL then system is not post the currency rev on open item on GL account.  It showing subject message and also show below mesaage:-
    Message no. FAGL_POST_SERVICE012
    Diagnosis
    You use GL account 210012 in company code 1000 with open item management. However, posting  are not permitted G/L accounts in individual ledger with open item management.
    Please advice on this issue.
    Thanks & Regards,
    Pankaj

    Hello Pankaj,
    Is your adjustment account was defiined as OI management. if yes, then t is generally not permitted to use the O/I managed account as an djustment account. The adjustment account is the same as O/I
    managed GL account, so the error message FAGL_POST_SERVICE012 is issued. This is justified because open items must be made valid for ALL ledgers in the client but FAGL_FC_TRANS posts ledger specific posting by having ledger group in the document header - Ledger Grp 0L.
    The best solution is to assign non-O/I managed account as an adjustment account, and this is the 'standard' solution.Please also check note 884639.
    Best Regards,
    Gladys xing

  • Postings to G/L accounts with open item management are not permitted Messag

    HI All,
    Me activiated New GL. and when I am trying to post the
    document, I am getting the below error.
    The GL used 200100 is Cash A/c (40)
    Cr Eq Share Capital A/c (50)
    As Cash A/c requires Clearing, I have activated "Open Item Management".
    Can you advice me why Its giving me the below mentioned error.
    Thanks
    Postings to G/L accounts with open item management are not permitted
    Message no. FAGL_POST_SERVICE012
    Diagnosis
    You use G/L account 200100 in company code RLIF with open item
    management. However, postings are not permitted to G/L accounts in
    individual ledgers with open item management.
    Procedure
    If you have not yet made any postings to this account and if the
    account is to be used for closing processes in non-leading ledgers,
    deactivate the Open Item Management indicator in the company code data
    for the G/L account.
    Thanks,
    Niranjan Yandamuri

    Hi,
    Please, refer to note 1646466 for the info on this message.
    Regards,
    Eli

Maybe you are looking for