Callback for a state change on digital Input 6025E

Hello All,
I need to have a callback function invoked when a state change occurs on serveral digital inputs (interlocks, kill button etc.).
I am using a PCI-6025E and traditional NI-DAQ. For test purposes I have connected the output P3.0 to the input P4.0 using a SCB-68
terminal block and initialize the ports in the following manner:
void initfunc()
long nPattern;
DIG_Prt_Config(1, 3, 0, 1); /* port 3 output */
DIG_Prt_Config(1, 4, 0, 0); /* port 4 input */
DIG_Out_Prt(1, 3, 0xff); /* set all outputs high */
DIG_In_Prt(1, 4, &nPattern); /* returns 0xff */
Config_DAQ_Event_Message (1, 1, "DI4", 8, 0xffff, 0xffff, 0, 0, 0, 0, 0, (unsigned long)(&myCallback)); /* callback on state change */
Now later in my program I perform the following (again as a test) when a button is pushed on a dialog box.
CDigioDlg:nKillBtn()
DIG_Out_Line(1, 3, 0, 0);
DIG_In_Prt(1, 4, &nPattern); /* returns 0xfe */
My callback funtion never gets called on the state change. Now looking at the documentation for the Config_DAQ_Event_Message it says that
it notifies traditional NI-DAQ applications when the status of an asynchronous DAQ operation (initiated by a call to DAQ_Start, DIG_Block_Out, WFM_Group_Control, and so on) meets certain criteria you specify.
Eventually this routines will need to monitor these input lines continuously within a DLL. I want to call an initialization function within
the DLL to configure the board and callbacks then return. I want the callback functions within the DLL to handle these state changes.
Any help would be greatly appreciated,
John

Hello John. Thank you for contacting National Instruments. It looks like you are using the callback incorrectly. I found an example that uses the callback in Visual C++ with Traditional DAQ. This isn't the same setup as you are using, but it should give you a good idea of how to setup the callback. Please let me know if you have any questions. Have a great day!
Marni S.
National Instruments
Attachments:
DAQEvent3VC6.zip ‏5 KB

Similar Messages

  • Callbacks for Process States

    Hi all,
    Are there any callbacks available for Process states(faulted,closed,completed) etc similar to callbacks for human workflow tasks in BPEL 1013? I need to handle the scenarios when a process is faulted or is aborted (from BPELConsole) and propagate this information to my application.
    thanks,
    Ravikiran

    This is normal exception handling. You just use the Fault handling in the SOAP response.
    Create a Fault message in your BPEL process and send this back to the client.

  • Monitor for State Change

    Hello,
    I am running SCOM 2012 R2 UR4.  Is it possible to setup a Windows Server monitor to notify me when the state change goes from Healthy to Critical?  I want to setup one alert to e-mail me regardless of the reason for the state change.

    Hi,
    Monitor only alert you once when the state changes and no further alerts will be triggered until the monitor normalize either by auto resolve or going back to the healthy state.
    If an alert is required every time a state change, you will have to configure a custom alert rule.
    Blog: http://theinfraguys.com
    Follow me at Facebook
    The Infra Guys Facebook Page
    Please remember to click Mark as Answer on the answer if it helps you in anyway

  • ACE Syslog message for State change

    Hi,
    Is there a syslog message for a state-change for rservers, if so how could we enable this?
    e.g. when probe fails state changes to 'probe-failed'
    when all probes are successful state is 'operational'
    Thank you
    Bilal

    Hi,
    There is a syslog message something like below:
    %ACE-3-251006: Health probe failed for server 10.80.10.10 on port 80 internal error: failed to setup a socket.
    First enable logging on ACE.
    ACE/Admin(config)# logging enable
    http://www.cisco.com/en/US/docs/app_ntwk_services/data_center_app_services/ace_appliances/vA1_7_/configuration/system/message/guide/config.html#wp1063750
    read the section:  Specifying Syslog Output Locations
    logging buffered 3 should generate syslog in event of probe failure.
    You can also set snmp to monitor it.
    cesRealServerStateChange
    CISCO-ENHANCED-
    SLB-MIB
    State of a real server configured in a server farm changed to a new  state as a result of something other than a user intervention. This  notification is sent for situations such as ARP failures, probe  failures, and so on.
    Hope that helps.
    regards,
    Ajay Kumar

  • Digital Inputs do not record over long time periods

    I am running Signals Express 2009 with a USB-6009.  I have a project that needs to record the states of 8 digital inputs over a 24 hour period.  The inputs typically do not change state for long periods of time.  When I run the project it does record and gather data if I stop it "soon"(I have gone as long as 30 min.)  When I leave it running overnight it does not appear to record anything.

    If you have not already, you should try turning off display updates in the "Operate »Update Signal Views While Running" menu item.  Set this to Update None.  Also, turn off "Prepare log data for viewing" under the Logging part in the Tools » Options dialog.  
    When I ran your project overnight, it ran out of memory.  The first error it threw was "Not enough memory to complete this operation."  The problem was that SignalExpress saved a great deal of data in memory for easy displaying while it's running, but this grows too big when it runs overnight.  The second error was as follows:
    Logging Stopped:
    Logging was stopped because an error occurred with a Step in the Project. 
    If this error is because of a device buffer overflow, you can improve performance by turning off display updates using the "Operate »Update Signal Views While Running" menu item.
    You can also change the way signals are logged by changing the Logging Options in the Tools»Options dialog.  
    Turning off  the "Prepare log data for viewing" will greatly improve performance. 
    Mark E.
    National Instruments
    Schedule a Free 1-Hour online LabVIEW Tutorial with an NI Applications Engineer

  • Actual time of digital input

    I am trying to record the actual time of the change in digital input pattern.

    Hello;
    You will probably need a combination of the digital board you have with a counter board.
    Then you can catch the intial time that the application starts, and then to count the PCKL pulses with the counter. You will need to stop the counter when the pattern you are looking for is matched (you can configire the 6534 board to generate a pulse when the pattern is match, and use that pulse to stop the counter).
    Since you know the TimeBase that the counter is using, to have the accurate time that the pattern was matched, you will need just to multiply the number of pulses the counter registered by the timebase, and add the initial time. I suggest you to work with the 660x counter board for that purpose.
    Hope this helps.
    Filipe A.
    Applications Engineer
    National Instruments

  • Can't change sample rate for digital input on Mac Pro

    Hello all,
    on my Mac Pro with 10.4.10 I can't change the sample rate for the digital input. Whenever I choose 48000 or 96000 Hz it returns to 44100 Hz after a few seconds. Feeding a 24 bit/96000 Hz signal from an external ADC into the optical input doesn't help. No input signal is available for digital recording software such as Sound Studio or Cubase. After changing the sample rate in audio midi configuration to 96000 Hz the sound can be heard for a few seconds but when the setup returns to 44100 automatically the signal is, of course, lost.
    I've deleted all relevant preferences and restarted with resetting paramter RAM. Still the same. With external hardware such as M-Audio Firewire equipment setting the sample rates works properly.
    Thanks to all for helpful clues.

    Hi,
    when E&M signaling is configured on digital interface like the VWIC is, 2 or 4 wires operation is not applicable because there are no wires at all, and reported only for compatibility with the analog E&M card.
    Consequently, you cannot configure that and it will not make any difference to effect of the connection.
    Please rate post if it helps!

  • NI-6023 digital inputs miss line state-changes

    I am using the NI-6023 DAQ to monitor digital lines. Occasionally (less than 1% of the time) the 6023 misses a low-to-high line state-change from . LabVIEW 6.1 polls the 6023 every 5 mS. The digital lines are normally low. When they go high, they remain high for only 50 mS.
    LabVIEW 6.1
    Windows 2000 Professional

    Hi Rchrd,
    If you're using a loop to poll your digital line, it's possible that you're not actually polling every 5 ms, since this is software timed. The speed is software/computer dependent, hence can depend on factors such as processor activity. Software timed I/O is normally used for low-speed applicatiosn that do not need hardware timed precision. You can do some troubleshooting by checking to see if there's a certain condition under which the state change is missed, and making sure you don't have other applications runing.
    Hope this helps.
    Thanks,
    Lesley Y.

  • How to wait for a digital input to go high?

    I bet the following question is explained somewhere but I don't know how to find it.
    Is there an optimal way to wait for a digital input to transition from 0 to 1? I mean, other than creating a loop that continously polls the input line is there a better way to wait for the transition? With all the "event driven" capability of CVI I suspect there's a slick way to do this but I don't know how to find it. I'm willing to RTFM if I know where to look.
    thanks

    Hi,
    I have never done this, but it looks like it is possible to use the DAQmxRegisterSignalEvent function to assign a function that will be called when a "change detection event" occurs.
    It works on a task basis, so if I'm not mistaken, you need to put the digital to be tracked into a separate task. 
    It is not stated if all NI hardware is compatible with this functionality, so try and see if it works for you.
    Hope this helps,
    Edit: It looks like you have already found the solution by yourself
    S. Eren BALCI
    www.aselsan.com.tr

  • WebLogicServer BEA-000365 Server state changed to FORCE_SHUTTING_DOWN at the time of bi services starting for obiee

    Hi Gurus,
    I have integrated Hyperion 11.1.2.3 with obiee 11g. Able to see obiee in workspace and Shared services. But suddenly we restarted the server. After that obiee link not working. It is showing Internet explorer could not open the web page. I have tried to start the bi services but the prompt ends with this error msg.
    <Aug 14, 2013 9:26:44 AM MST> <Critical> <Security> <BEA-090402> <Authentication denied: Boot identity not valid; The user name and/or password from the boot id
    entity file (boot.properties) is not valid. The boot identity may have been changed since the boot identity file was created. Please edit and update the boot id
    entity file with the proper values of username and password. The first time the updated boot identity file is used to start the server, these new values are enc
    rypted.>
    <Aug 14, 2013 9:26:44 AM MST> <Critical> <WebLogicServer> <BEA-000386> <Server subsystem failed. Reason: weblogic.security.SecurityInitializationException: Auth
    entication denied: Boot identity not valid; The user name and/or password from the boot identity file (boot.properties) is not valid. The boot identity may have
    been changed since the boot identity file was created. Please edit and update the boot identity file with the proper values of username and password. The first
    time the updated boot identity file is used to start the server, these new values are encrypted.
    weblogic.security.SecurityInitializationException: Authentication denied: Boot identity not valid; The user name and/or password from the boot identity file (bo
    ot.properties) is not valid. The boot identity may have been changed since the boot identity file was created. Please edit and update the boot identity file wit
    h the proper values of username and password. The first time the updated boot identity file is used to start the server, these new values are encrypted.
            at weblogic.security.service.CommonSecurityServiceManagerDelegateImpl.doBootAuthorization(CommonSecurityServiceManagerDelegateImpl.java:959)
            at weblogic.security.service.CommonSecurityServiceManagerDelegateImpl.initialize(CommonSecurityServiceManagerDelegateImpl.java:1050)
            at weblogic.security.service.SecurityServiceManager.initialize(SecurityServiceManager.java:873)
            at weblogic.security.SecurityService.start(SecurityService.java:141)
            at weblogic.t3.srvr.SubsystemRequest.run(SubsystemRequest.java:64)
            Truncated. see log file for complete stacktrace
    Caused By: javax.security.auth.login.FailedLoginException: [Security:090303]Authentication Failed: User epm_admin weblogic.security.providers.authentication.LDA
    PAtnDelegateException: [Security:090295]caught unexpected exception
            at weblogic.security.providers.authentication.LDAPAtnLoginModuleImpl.login(LDAPAtnLoginModuleImpl.java:251)
            at com.bea.common.security.internal.service.LoginModuleWrapper$1.run(LoginModuleWrapper.java:110)
            at java.security.AccessController.doPrivileged(Native Method)
            at com.bea.common.security.internal.service.LoginModuleWrapper.login(LoginModuleWrapper.java:106)
            at sun.reflect.NativeMethodAccessorImpl.invoke0(Native Method)
            Truncated. see log file for complete stacktrace
    >
    <Aug 14, 2013 9:26:44 AM MST> <Notice> <WebLogicServer> <BEA-000365> <Server state changed to FAILED>
    <Aug 14, 2013 9:26:44 AM MST> <Error> <WebLogicServer> <BEA-000383> <A criticalservice failed. The server will shut itself down>
    <Aug 14, 2013 9:26:44 AM MST> <Notice> <WebLogicServer> <BEA-000365> <Server state changed to FORCE_SHUTTING_DOWN>
    I have deleted password and username in boot.properties of Admin Server and bi_security1 folder but no use. Other option, i have deleted boot.properties then in the bi services prompt entered weblogic server username and password. Now also same issue.
    please help me, to resolve this issue.
    Thanks

    we need to change the Weblogic Username and Password which is saved in boot.properties file
    Thanks,
    Madhu

  • I am trying to do a blank composition widget, but it keeps ignoring my state changes for the trigger. How can I have my state changes still work for things placed in the trigger?

    So below is what I have so far. The menu is working perfectly, thanks to a few Youtube tutorials. And everything is linked correctly. But the only thing is that the "WORK" button doesn't respond to the state change that is set up for it. I tried applying the state change before I placed it in the trigger area, and after. Neither seems to make it work.
    The goal state change is basically that the text "WORK" will turn white, and the white space within the teal stroke will also turn teal. So, the colors will reverse. I have a link next to it, "ABOUT" that is currently successfully doing it. I guess if it's not possible then I will have to figure out another design..but I'd like to see if there is a way to do it!

    I believe you are trying to get a color state for composition when its active ? please publish the site and provide the url to have a look.
    Thanks,
    Sanjit

  • "External sample clock" and "Rate" for digital input acquisition

    Dear all,
    I want to acquire digital input (21 bits with external clock = 50 kHz) with a PCIe-6343 NI board. Using the  DAQ assistant under Labview, I selected the advanced timing with the sample clock time parametrized as External. However, it is also possible to select the Rate of the acquisition. In my case, i want to get the data at the rising edge of the external clock signal, so at a frequency of 50 kHz.  How can I do that ? I just need to put a Rate of 50 kHz ?
    thanks for your help.
    Cedric 

    Cedric,
    dddsdsds wrote: 
    [...]In my case, i want to get the data at the rising edge of the external clock signal, so at a frequency of 50 kHz.  How can I do that ?[...]
    You answered your question already. If you want to use an external clock, you have to configure the timing source of your task to be external. In order of proper buffer configuration, you should enter 50kHz as rate in addition to the external configuration, but this will not influence the speed of the acquisition (since it is "clocked" externally!)
    hope this helps,
    Norbert
    CEO: What exactly is stopping us from doing this?
    Expert: Geometry
    Marketing Manager: Just ignore it.

  • Change the background color for HToggleButton as State changed

    Hi , I want to change the background color of HToggleButton or HGraphicButton as its state changed as normal to focus and then focus to normal and same with actioned state .It is possible to change the image with different states but how can I do the same thing to change background color .I'll appreciate any help regarding this with thanks in adv.

    Satya,
    i_x denotes first column and not characctersitic 1.
    Also I am not sure if the check is to be for IS_SUM.
    Use Get_Cell_info class instance and then use the data returned by the same for checking IS_SUM and then change the cellstyle.
    Another thing to look out for is , the required change might be needed on DATA_CELL and notcharacteristic_cell.
    Arun
    Assigning points is a way of saying thank you on SDN

  • Agent state changed to reserved but call is not ringing/landing for 30 seconds

    Hi All,
    we have IPCC 8.5, CVP 8.5, UCM 8.5, last few weeks we are facing
    agents are facing intermittently, their state changed to reserved but call is not landing/ring for a while, and we have seen call is going to RONA in CVP logs.
    We have cross checked the Device Target (4 CVP servers) its fine, Queue music is interruptable.
    In Ingress/VXML gateway we have the dial-peer pointing to two subscribers with equal priority. Seems to be some call is not routing to agent phone (delay is there between voice gateway and ip phone) due to some reason. We dont use SIP proxy we use static routing to subscribers.
    Please share your ideas.
    with Regards,
    Manivanna                  

    In Ingress/VXML gateway we have the dial-peer pointing to two subscribers with equal priority.
    The gateway should point to the Call Servers. The Call Servers should have static routes to the subscribers.
    If the call is not getting to the agent even though they go into Reserved (the Call Router has selected them), ensure that the SIP trunks to the Call Servers and the agent phones are in compatible partitions/CSS. Examine the logs on the Call Server when the INVITE is sent to the agent phone. If the INVITE returns 404 (not found) or 503 (unavailable), then the setup is wrong.
    Regards,
    Geoff

  • I am new to apple having worked with microsoft all these years.  The switch was more for my photos. iPhoto seem to have changed my digital albums into tiff. All pictures are now in very small resolution. Can anyone out there help me retrieve my photos. Ta

    I am new to apple software having worked with microsoft all these years. The switch was mainly for my photographs. Iphotos seemed to have changed all digital albums from jpeg to tiff format hence the very small resolution. Can anyone out there please help me recover these photos to origianal format???
    Thanks
    suvieve63

    Gosh I am already tired of trying to retrieve this photo album and it seems like a waste of time and money spent on an apple IMac.
    No disrespect intended but until you learn how iPhoto and Macs work you will continue to be confused and frustrated. 
    You say you want to create a book in iPhoto and have it printed by Apple, right.  Have you finished creating  the book in iPhoto? If so the Control (right) - click in the View all pages window background and select Save Book as  PDF in the contextual menu?
    Open the the PDF file with Preview and check for any errors or problems.  If there are none you can order the book by clicking oin the Buy Book button at the bottom. Save the pdf file to compare with the printed book when it arrives in you feel there's a problem with it.  That's all you need to do.  There's no use of the Finder required.
    OT

Maybe you are looking for

  • 100000 records resultset giving problem ?

    Hello All, I am using oracle database, windows 2000, OC4J(Oracle Containers for j2ee) Application Server. When I query a emp table which has 100000 records and store the 100000 records in resultset and using a while loop if I iterates through the res

  • Removing duplicated messages in Apple Mail

    Is there any way to do that automatically? I don't want to browse through thousands of e-mails to remove duplicates manually?

  • CRM_ORDER_MAINTAIN / SAVE don't work?

    Hello, I want to change the priority of a CRM order(e.g. Object-id: 9999000241 , Header-GUID: F3330F14B8A20A43BEEDDD3B6791395F). According to some threads here, I used three FMs: CRM_ORDER_MAINTAIN, CRM_ORDER_SAVE and CRM_ORDER_INITIALIZE. I pasted t

  • BAPI_SALESORDER_CREATEFROMDAT2 configure error information

    hi every body: I use BAPI_SALESORDER_CREATEFROMDAT2 to creat a SO ,when i need to configure it's item, the thing come out "S V4                   233 SALES_HEADER_IN has been processed successfully A CU                   013 Internal error: 10, 00001

  • Adding elements to a Dialog after it's been created using a resource string

    I can add elements using add but not with a resource string. The following works in ExtendScript Toolkit but not in Photoshop. Any idea why? var window_res = "dialog { \      orientation: 'row', \      alignChildren: 'top', \      preferredSize: [500