CIMC Access After Integrating C Series with UCS Manager
My question relates to the following language:
This guide contains information and procedures for installing Cisco UCS C200, C210 and C250 servers for integration with Cisco UCS Manager release 1.4 or 2.0.1.
Cisco UCS C-Series Rack-Mount Servers are managed by the built-in standalone software, Cisco Integrated Management Controller (CIMC) . When a C-Series Rack-Mount Serveris integrated with Cisco UCS Manager, the CIMC does not manage the server anymore. Instead it is managed with the Cisco UCS Manager software. You will manage the server using the Cisco UCS Manager GUI or Cisco UCS Manager CLI.
Does this mean that you literally are unable to web to the CIMC GUI? Or does it mean that although you can still access the CIMC, the management of the C Series is recommended to be performed via the UCS Manager?
Are they mutually exclusive?
Thanks,
Amir
Just saw this:
These UCSM mode settings enable DHCP, Active-Active NIC redundancy, and Shared LOM NIC mode, which enables CIMC control through the 1-Gb LOM ports, rather than the management port. Any static IP addresses and the management port are disabled, so you lose connection with the CIMC.
So it appears that they are mutually exclusive.
Similar Messages
-
How to move a standalone Cisco C series to UCS managed service profile without losing data?
Hi,
We currently have a standalone cisco C series server with Windows 2012 installed on the local disks. We need to move this server to Cisco UCS managed with a service profile but cannot lose the existing data and OS boot method.
Does anyone know how to do this?
ThanksHi Adrian,
To be able to accomplish this set the local disk policy to "Any Configuration" this way UCSM won't overwrite the current raid configuration on the server.
See link below
http://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/sw/gui/config/guide/2-1/b_UCSM_GUI_Configuration_Guide_2_1/b_UCSM_GUI_Configuration_Guide_2_1_chapter_011110.html#task_897FABF194524BDF8C0EF72E755972F0
Let it me know if this helps -
Best Approach for integrating SAP CRM with Outage Management System
Hi All,
We are moving towards deploying Outage Management System (Oracle Utilities NMS) to help localize the fault, achieve Outage Management and a transparent network with a near-real time stats. We already have SAP ECC 6.0, ISU, SAP PI 7.0 and SAP CRM 7.0. One of the challenges we are facing is to decide how should we go about the integration of SAP CRM with Oracle's Outage Management System.
Here is a sample business scenario,
CSR receives a call from a consumer and inquires about planned outages for a particular area.
This information is contained in the Outage Management System (OMS). OMS is SOA based and is hosted on Oracle Service Bus.
I want to know that is there any ES Bundles available for CRM-OMS integration? Should we go about Service Based Integration? What are the alternatives to Service based integration? Can it be done using BAPIs?
We receive around 1000 consumer complains and against every complain a ticket is generated in CRM. Now If CRM is integrated with OMS using SAP PI, the volume of the data being exchanged via PI is very much high and exceeds our licensed volume for SAP PI. So I do need to know the best practices for either approach that you may recommend.
Regards,
Adil Khalildoes anyone have an idea about this one, I've asked this question in a few places and no one really seems clear about it.
Also, I've read here and there that SAP Business One is not a real SAP product. It was bought by SAP and is sold by them but has little do to with SAP's technology (R/3, SAP ERP, Netweaver, SAP CRM, ...), and that therefore they don't support it that much ? Is any of this right ?
I'm just trying to get my vision of the SAP universe clear.
Angela -
Integrating Trex search With Solution manager
HI Guys,
Please help me with this .
Let's say the solution manager is integrated in the SAP Portal and trex is available in the SAP portal.
Can we search documents stored in the solution manager via the trex which is integrated in the SAP Portal? Is there a how-to guide available on the config?
Any thoughts are appreciated.
Dev.Hi Dev
I'm facing a similar problem.
We have a trex server. We connected the TRex to our EP KM. Fulltext search in our Portal KM works well.
We have several project documentations on our Solution Manager. I was hoping I could connect the KM repository of the solution manager to our TREX and search the docs from EP. I was able to connect the Solution Manager repository to Trex. The index is working well.
The procedure is described in note 750623 but unfortunately the note is far away from a how to guide so I hope this helps:
Trex:
- Go to Admin Tool. Then landscape - connectivity and click on create "Connection". Enter system information of your solution manager system. Then click on Create - RFC Destination (sm59).
Solution Manager:
- Transaction srmo: Create a new Search Server Relation (DRFUZZY) and enter the RFC Destination you created in the above step and set it to default.
- Transaction spro: SAP Solution Manager - Cross-Scenario Settings - Document Management - Servers - Connect Index Server for Full Text Search. Click on "Define Index Readiness" and mark both entries for "IWBSolar" and save.
- Now go tou se38 and start the report RSTIRIDX_REINDEX. Here enter IWBSOlAR for document area and execute.
- Now go back to spro: Start the IMG activity "Schedule Asynchronous Indexing and De-indexing" and schedule the indexing job (Make sure you have executed the report RSTIRIDX_REINDEX before).
If you want to test the search go to transaction SKPR07, go to tools, select document area IWB Solar and click on "test search".
Unfortunately I don't know if there is any bether transaction for the search.
I was looking for a possibility to search from EP directly to the solman KM. But unfortunately I didnt' find a solution for this. The only way I know is to connect the solution manager over a transaction iview im EP.
Hope I could help.
Marco -
Integrating ecc6.0 with soultion manager
Hi All,
Could some please let me how to integrate soultion manager system to ecc6.0 or 4.7 server after installing sap in unix or windows server.
And also let me know how to integrate Bi or any other sap servers with r/3.
please provide steps in detail if some one have.
Thanks in advance.
kishoreHi Dude,
Thanks for replying me soon, could you pelase let me know what steps need to be followed in soultion manager.
Thanks, -
LMS 3.1 Slow after integrating with ACS
Dear All, have any one faced issue of slowness after integrating LMS3.1 with ACS4.2. I dont know how can I resolve this issue. Is there any patch to resolve it...
Any kind of help will be very helpful.I'm using LMS 3.2 into ACS 4.0 and it actually seemed a bit faster after ACS integration. Nothing I measured but subjectively it seems faster. Both my servers are on Windows and the ACS is across the WAN from my CiscoWorks.
How do your devices fare with their ACS? You can debug tacacs at the router/switch level as one tool. I'm sure one of the cisco guys on here will point you to one of the many logs that LMS generates, possibly with debugging activated, to dig deeper there also. -
BI Publisher 11.1.1.5 is installed in Host A and Enterprise Manager 12.1.0.1 is installed in Host B.
All the samples and steps given in the oracle doc explains how to integrate them if they are in the same host.
./configureBIP
But how to integrate them if they are on different hosts?Hi Anandh,
Bi publisher cannot be integrated with EM 12c is its running on a different host
Below are the scenarios
For Standalone OMS setup
BI Publisher can only be installed only on the 12c OMS host in case of standalone OMS setup
For multi oms setup
BI Publisher can only be installed only on the Primary OMS in a Multi-OMS setup.
Ref
How to Integrate BI Publisher (BIP) After Fresh Install or Upgrade of EM 12c Cloud Control ? (Doc ID 1392921.1)
16 Integrating BI Publisher with Enterprise Manager
http://docs.oracle.com/html/E24089_15/install_em_bip.htm#CHDHJFEC
Regards,
Rahul -
Nexus 1000v UCS Manager and Cisco UCS M81KR
Hello everyone
I am confused about how works the integration between N1K and UCS Manager:
First question:
If two VMs on different ESXi and different VEM but in the same VLAN,would like to talk each other, the data flow between them is managed from the upstream switch( in this case UCS Fabric Inteconnect), isn'it?
I created a Ethernet uplink port-profile on N1K in switch port mode access(100), I created a vEthernet port-profile for the VM in switchport mode access(100) as well. In the Fabric Interconnect I created a vNIC profile for the physical NICs of ESXi(where there are the VMs). Also I created the vlan 100(the same in N1K)
Second question: With the configuration above, if I include in the vNIC profile the vlan 100 (not as native vlan) only, the two VMs can not ping each other. Instead if I include in the vNIC profile only the defaul vlan(I think it is the vlan 1) as native vlan evereything works fine. WHY????
Third question: How it works the tagging vlan on Fabric interconnectr and also in N1K.
I tried to read differnt documents, but I did not understand.
ThanksThis document may help...
Best Practices in Deploying Cisco Nexus 1000V Series Switches on Cisco UCS B and C Series Cisco UCS Manager Servers
http://www.cisco.com/en/US/prod/collateral/switches/ps9441/ps9902/white_paper_c11-558242.html
If two VMs on different ESXi and different VEM but in the same VLAN,would like to talk each other, the data flow between them is managed from the upstream switch( in this case UCS Fabric Inteconnect), isn'it?
-Yes. Each ESX host with the VEM will have one or more dedicated NICs for the VEMs to communicate with the upstream network. These would be your 'type ethernet' port-profiles. The ustream network would need to bridge the vlan between the two physicall nics.
Second question: With the configuration above, if I include in the vNIC profile the vlan 100 (not as native vlan) only, the two VMs can not ping each other. Instead if I include in the vNIC profile only the defaul vlan(I think it is the vlan 1) as native vlan evereything works fine. WHY????
- The N1K port profiles are switchport access making them untagged. This would be the native vlan in ucs. If there is no native vlan in the UCS configuration, we do not have the upstream networking bridging the vlan.
Third question: How it works the tagging vlan on Fabric interconnectr and also in N1K.
- All ports on the UCS are effectively trunks and you can define what vlans are allowed on the trunk as well as what vlan is passed natively or untagged. In N1K, you will want to leave your vEthernet port profiles as 'switchport mode access'. For your Ethernet profiles, you will want them to be 'switchport mode trunk'. Use an used used vlan as the native vlan. All production vlans will be passed from N1K to UCS as tagged vlans.
Thank You,
Dan Laden
PDI Helpdesk
http://www.cisco.com/go/pdihelpdesk -
Hello everyone
I am confused about how works the integration between N1K and UCS Manager:
First question:
If two VMs on different ESXi and different VEM but in the same VLAN,would like to talk each other, the data flow between them is managed from the upstream switch( in this case UCS Fabric Inteconnect), isn'it?
I created a Ethernet uplink port-profile on N1K in switch port mode access(100), I created a vEthernet port-profile for the VM in switchport mode access(100) as well. In the Fabric Interconnect I created a vNIC profile for the physical NICs of ESXi(where there are the VMs). Also I created the vlan 100(the same in N1K)
Second question: With the configuration above, if I include in the vNIC profile the vlan 100 (not as native vlan) only, the two VMs can not ping each other. Instead if I include in the vNIC profile only the defaul vlan(I think it is the vlan 1) as native vlan evereything works fine. WHY????
Third question: How it works the tagging vlan on Fabric interconnectr and also in N1K.
I tried to read differnt documents, but I did not understand.
ThanksSince you have defined switchport mode access vlan 100 on uplink port-profile of Nexus 1000v, it sends all ethernet frames untagged(without 802.1q tag).
When you include in the vNIC profile the vlan 100 (not as native vlan) ONLY like below screenshot, untagged frames are dropped because UCS expects all frames received on this port as tagged frames.
When you change vNIC template to include default vlan as native vlan ONLY like below screen shot, you basically bridge two vlans (vlan 100 and vlan 1) because UCS FI now puts all untagged frames in vlan 1. and sends untagged frames to other ESXi host and ESXi host again bridge vlan 1 to vlan 100 with switchport mode access vlan 100 on uplink port profile. -
JCAPS 6 with Enterprise manager 5.1.3
I have a problem to use JCAPS 6 with eManager 5.1.3.
I have installed JCAPS 6 in my PC and I want to use emanager 5.1.3 to monitorate an integration but //localhost:15000/eManager don't permit me the connection.
This is the message:
Connection failed. Please check the following:
- Server type is correct.
- Server is running.
- Hostname and Port number(s) are correct.
- Server SSL configuration.
I controlled every item but I don't understand how to make the connection.
Can you help me about? Thanx
Best regards
FabrizioHi Anandh,
Bi publisher cannot be integrated with EM 12c is its running on a different host
Below are the scenarios
For Standalone OMS setup
BI Publisher can only be installed only on the 12c OMS host in case of standalone OMS setup
For multi oms setup
BI Publisher can only be installed only on the Primary OMS in a Multi-OMS setup.
Ref
How to Integrate BI Publisher (BIP) After Fresh Install or Upgrade of EM 12c Cloud Control ? (Doc ID 1392921.1)
16 Integrating BI Publisher with Enterprise Manager
http://docs.oracle.com/html/E24089_15/install_em_bip.htm#CHDHJFEC
Regards,
Rahul -
SharePoint Designer 2013 after installation getting error with runtime i.e. error writing to file Microsoft.SharePoint.Client.Runtime.Local.Resources.dll Verify that you have access to that directory
after retry..again SharePoint Designer requires the following component require to install Microsoft.NET framework version 4 i have downloaded and try to installed but fail not work please answer what to do?
Thanks and Regards, Rangnath MaliHi Rangnath,
For running SharePoint Designer 2013, you need to install Microsoft .NET 4.0 Framework or higher.
Please uninstall the Microsoft .NET 4.0 Framework, and install it again. After that, reboot your machine.
Best Regards,
Wendy
Wendy Li
TechNet Community Support -
The problem with forecast reports in SCOM 2012 after integration with VMM 2012
Hello.
I have problem with forecast reports in SCOM 2012 after integration with VMM 2012. All other reports (not forecasting) works fine. For example, report “Host Group Forecasting” don’t work. The report is generated, but I have error: “Subreport
could not be shown”. I find only errors in SQL Server Reporting logs like this:
library!ReportServer_0-13!1758!06/26/2012-18:26:23:: i INFO: RenderForNewSession('/Microsoft.SystemCenter.VirtualMachineManager.2012.Reports/Microsoft.SystemCenter.VirtualMachineManager.2012.Report.ForecastHostGroup')
processing!ReportServer_0-13!1758!06/26/2012-18:26:28:: e ERROR: Throwing Microsoft.ReportingServices.ReportProcessing.ReportProcessingException: , Microsoft.ReportingServices.ReportProcessing.ReportProcessingException: Не удалось выполнить
запрос для набора данных "DiskSpaceUsageForecasting". ---> Microsoft.AnalysisServices.AdomdClient.AdomdErrorResponseException: Execution of the managed stored procedure GetTimeSeriesForecast failed with the following error: Exception has been thrown by
the target of an invocation..
Query (5, 58) Parser: The syntax for '6' is incorrect.
at Microsoft.AnalysisServices.AdomdClient.AdomdConnection.XmlaClientProvider.Microsoft.AnalysisServices.AdomdClient.IExecuteProvider.ExecuteTabular(CommandBehavior behavior, ICommandContentProvider contentProvider,
AdomdPropertyCollection commandProperties, IDataParameterCollection parameters)
at Microsoft.AnalysisServices.AdomdClient.AdomdCommand.ExecuteReader(CommandBehavior behavior)
at Microsoft.AnalysisServices.AdomdClient.AdomdCommand.System.Data.IDbCommand.ExecuteReader(CommandBehavior behavior)
at Microsoft.ReportingServices.DataExtensions.AdoMdCommand.ExecuteReader(CommandBehavior behavior)
at Microsoft.ReportingServices.OnDemandProcessing.RuntimeDataSet.RunEmbeddedQuery(Boolean& readerExtensionsSupported, Boolean& readerFieldProperties, List`1 queryParams, Object[] paramValues)
--- End of inner exception stack trace ---;
The Russian string “Не удалось
выполнить запрос для набора данных "DiskSpaceUsageForecasting"” is translated to “Could not execute query for data set "DiskSpaceUsageForecasting"”.
I have clean installation SCOM 2012 RU1, VMM 2012 RU1. Integration SCOM with VMM work fine.
SQL collation for all SQL DB instances (SCOM and VMM and SCOM reporting) – “SQL_Latin1_General_CP1_CI_AS”
SQL Analysis service: SQL collation – “Latin1_General” ; language for the server – English (United States)
I think the problem in regional settings. By my opinion there are two possible mistakes:
SQL collation for all SQL DB instances. May be need use “Latin1_General_CI_AS”
as provided by
http://blogs.technet.com/b/momteam/archive/2012/05/25/clarification-on-sql-server-collation-requirements-for-system-center-2012.aspx
Need change regional setting. Question is for what (OS regional setting, SQL Analysis service settings,…) ?Error: Subreport could not be shown
Opening a report for Client Security might result in the following error being displayed in one or more areas of the report: "Error: Subreport could not be shown."
Background
There are two possible reasons for this error:
1. Wrong location The reporting server is pointing to the wrong computer running SQL Server or a SQL Server instance.
2. Insufficient permissions The account configured (in SQL Server Reporting Services) to connect to the reporting database does not have appropriate permissions for the database.
Solution
To determine which reason is causing the error, attempt to directly open the subreport reporting the error, by clicking the name of the subreport.
If the reporting server is pointing to a wrong location, the report displays an error similar to the following:
Error message
An error has occurred during report processing.
Cannot create a connection to data source 'SystemCenterReporting'. Cannot open database "SystemCenterReporting" requested by the login. The login failed. Login failed for user username.
To verify the correct SQL Server computer and instance path
In Report Manager, navigate to the report generating the error and click the Properties tab.
Click Data Sources and under a Shared data source, note the path.
Open the reporting Web site. If you chose the default virtual directory for reports, the URL is: http://hostname/Reports/
If you chose to secure the viewing of reports with HTTPS, the URL is: https://hostname/Reports/
Click SCDW.
In the Connection type list, ensure that Microsoft SQL Server is selected.
In the Connection string box, ensure that the correct SQL Server computer and instance name are entered.
Note:
A period (.) denotes the local computer.
If the account has insufficient permissions, the report displays an error similar to the following:
Error message
An error has occurred during report processing. (rsProcessingAborted) Query execution failed for data set 'DSDashboardComputersTrend'. (rsErrorExecutingCommand) EXECUTE permission denied on object 'prSAS_UX_DashboardComputersTrend', database 'SystemCenterReporting',
schema 'dbo'.
To determine if you are experiencing the SQL Server permissions issue
Open the reporting Web site. If you chose the default virtual directory for reports, the URL is:http://hostname/Reportserver/
If you chose to secure the viewing of reports with HTTPS, the URL is:https://hostname/Reportserver/
Click Microsoft Operations Manager Reporting, click Microsoft Forefront Client Security, and scroll to DashboardComputersTrend.
Click DashboardComputersTrend.
If you are experiencing a SQL Server permissions issue, an error similar to the preceding error appears.
To grant permissions to the SQL Server computer
1. In Report Manager, click SCDW and note the account in the Connect using section. This is the account under which the database is contacted.
2. On the server with the System Center Reporting database, start SQL Server Management Studio.
3. In the tree, expand Security, and then expand Logins. Do one of the following:
If the user account is listed, right-click the account, click Properties, and then go to step 5.
If the user account is not listed, right-click Logins and choose New Login.
4. In the Login name box, enter the user account (domain\username).
5. In the Login Properties dialog box, click User Mapping, and then under Users mapped to this login, select the System Center Reporting check box.
6. Under Database role membership for: System Center Reporting, select the db_owner check box, and then click OK.
Thanks,
Yog Li
TechNet Community Support -
How do I access files that have been recovered (after a Mavericks problem) with the .cca file extension
First, to access documents you must use an app designed for that specific Document type. So Pages will not be able to open PDFs. The Documents app by Readdle can handle PDFs though. In the latter case, you'd open the app, click the menu icon at its top left, and click Open to go to your iCloud Drive. With Pages, if you had files outside the main Pages folder, click + then iCloud and navigate to the file's location.
Matt -
Problems with network access after applying batch of updates
Hi all,
Yesterday, I've applied a batch of updates to my Windows Server 2012 Hyper-V server. All went good, but after the reboot I was not able to access... Microsoft website for update download, or WSUS to Report and detect updates.
For my troubleshooting I did:
ping www.microsoft.com (DNS goes well)
With Wireshark running, did a http request to www.microsoft.com and I don't see any request leaving the NIC. This goes to *.microsoft.com
This happens either with or without Proxy set up.
I've reset Internet Explorer Settings, all with no luck.
When trying over our WSUS, I get error 80244019, and with wireshark I can see that WSUS may not be able to get the updates because it is replying with 404 not found.
HEAD /Content/C5/EC7E6D6C8063BF4424CE2EC75EBC977953CF11C5.cab HTTP/1.1
Connection: Keep-Alive
Accept: */*
Accept-Encoding: identity
User-Agent: Microsoft BITS/7.6
Host: srv-dc-sys:8530
HTTP/1.1 404 Not Found
Content-Length: 1245
Content-Type: text/html
Server: Microsoft-IIS/8.0
X-Powered-By: ASP.NET
Date: Wed, 14 Jan 2015 10:34:49 GMT
HEAD /Content/C5/EC7E6D6C8063BF4424CE2EC75EBC977953CF11C5.cab HTTP/1.1
Connection: Keep-Alive
Accept: */*
Accept-Encoding: identity
User-Agent: Microsoft BITS/7.6
Host: srv-dc-sys:8530
HTTP/1.1 404 Not Found
Content-Length: 1245
Content-Type: text/html
Server: Microsoft-IIS/8.0
X-Powered-By: ASP.NET
Date: Wed, 14 Jan 2015 10:34:49 GMT
HEAD /Content/C5/EC7E6D6C8063BF4424CE2EC75EBC977953CF11C5.cab HTTP/1.1
Connection: Keep-Alive
Accept: */*
Accept-Encoding: identity
User-Agent: Microsoft BITS/7.6
Host: srv-dc-sys:8530
HTTP/1.1 404 Not Found
Content-Length: 1245
Content-Type: text/html
Server: Microsoft-IIS/8.0
X-Powered-By: ASP.NET
Date: Wed, 14 Jan 2015 10:34:49 GMT
Seems to me two issues here. One I might workaround with deleting the WSUS content, and let WSUS resync(may solve).
The other... It's strange because can't seem to have www.microsoft.com leave my nic...
As part of the troubleshooting, I have two nics teamed, 1 nic for live migration, 1 nic for cluster network, and teaming, obviously has itself a single default gateway.
What can I do to go forward?
PS: One last finding. In WSUS this server does not report since 13th January at 11:00 a.m. I've forced it to report, and still no update/report
Nuno SilvaHi Nuno,
Do you mean that you can't see a HTTP request of
www.microsoft.com when you access it with Internet Explorer?
Can you successfully access the www.microsoft.com with the Internet Explorer? If yes, it should be normal. Because
www.microsoft.com is a CNAME.
>>but after the reboot I was not able to access... Microsoft website for update download, or WSUS to Report and detect updates.
Please try to update from Microsoft Update. Then post the windowsupdate.log here. It may give some hints.
Best Regards.
Steven Lee Please remember to mark the replies as answers if they help and unmark them if they provide no help. If you have feedback for TechNet Support, contact [email protected] -
Hi,
I have recently installed iTunes latest version (10.5.1.42) on Win XP SP3.
The problem is, when accessing iTunes, It connects to the internet, I can sign in (It shows my username in sign in bar), But nothing is shown in the iTunes store window in iTunes. It shows "accessing iTunes store..." for few seconds and after that its blank with an apple logo inside the status bar.
ANU SUGGESSION???Sorry, no. The screen image you see is specifically saying you need to connect it to a computer. You could take it to an Apple retailer for help.
Maybe you are looking for
-
Display data from BLOB column.
Hi All, I want to display data from blob datatype field, which contains HTML and GIF both files. If I set it's property from file format IMAGE then i get data only gif. if anybody have answer plz revert back... awaiting... Juned
-
i need help my mp3 play is stuck in recovery mode and warranty is done
-
Hi, Can anyone give me some instructions on how to print a VAS order? When I try to print a VAS order template, I just get the message "Some error occured during printing". Debugging it I found that some values are missing but I don't know where to d
-
All my applications dissapeared (Including Phone and SMS)
I clicked on the App Store to look for a new app and it froze. As usual I forced a reboot. When it turned back on, all of my applications were gone. Everything. Even the Phone and SMS. The only thing that was there were the Web Clips I had saved whic
-
Recently I installed Arch 2010.05 on an Acer 1410 notebook. The operating system runs perfectly fine except for the wired internet card and wireless internet card. The wireless card on that notebook never worked, so I'm not too concerned about that