Hi all,
Hi have install a cisco nexus 7010 with the following modules :
Mod  Ports  Module-Type                         Model              Status
1    48     1000 Mbps Optical Ethernet XL Modul N7K-M148GS-11L     ok
2    48     10/100/1000 Mbps Ethernet XL Module N7K-M148GT-11L     ok
5    0      Supervisor Module-2                 N7K-SUP2           active *
6    0      Supervisor Module-2                 N7K-SUP2           ha-standby
9    48     10/100/1000 Mbps Ethernet XL Module N7K-M148GT-11L     ok
10   48     1/10 Gbps Ethernet Module           N7K-F248XP-25E     ok
After trying to build a port-channel with a 1G port on slot 1 and a 1G port on slot 10 i get a messague with incompatible port.
Can any one tell me if its supported a port-channel with ports on the following modules :
N7K-M148GS-11L
N7K-F248XP-25E
Thanks
Patrício

Hi Particio,
The port-channel/vPC features require that all uplinks are connected to the same type of
module. You can refer to the following document.
http://www.cisco.com/en/US/partner/docs/switches/datacenter/sw/6_x/nx-os/interfaces/configuration/guide/if_portchannel.html#wp1888267
HTH
Regards
Inayath
*Plz rate if this is helpfull and mark as Answerd if this answerd your query.

Similar Messages

  • Nexus 7010 port-channel to ESXi host running on Dell 910 and 810

    Was wondering has anyone had any experience with configuring a port-channel going back to ESXi host. My basic config is below. My issue is with what to put in the spanning-tree port type. Do I use normal, edge, network, or edge trunk?? Yes I have read most of the documentation out there but am just a lil confused. I just wanna be right.
    Also if anyone has any suggestions for the Vswitch config as well that would be much appreciated.
    int PO 201
    desc 01_6-1
    switchport mode trunk
      switchport access vlan 99
      switchport trunk native vlan 777
      switchport trunk allowed vlan 220,300,310,320-321,350,390-391
      switchport trunk allowed vlan add 420,777
      spanning-tree port type normal (what should go here)
      speed auto
      medium p2p
      no shutdown
    int e8/11
    desc 01_6-1
    channel-group 201 force
    int e10/11
    desc 01_6-1
    channel-group 201 force
    Thanks Guys

    Short answer: You could use spanning tree port type edge (trunk; if it's going to be a trunk). The vswitch isn't really a switch, it doesn't participate in spanning tree, so it's fine to make it an edge port.
    In my experience, many VMware guys don't like port channels as much as the other more host-centric NIC teaming methods. I think this has to do with ESX having a less than stellar implementation of etherchannel/LACP early on.

  • Nexus 7010 port-channel failed, not receiving any LACP BPDUs

    Hi every one,
    I'm having issue when trying to form LACP etherchannel links between N7k and server. Here's the setup:
    SERVER eth0-------N7K-1 Eth102/1/9
    SERVER eth1-------N7K-2 Eth102/1/9
    Configuration:
    N7K-1# sh run int eth102/1/9
    interface Ethernet102/1/9
      switchport
      switchport access vlan 204
      channel-group 321
      no shutdown
    N7K-1# sh run int po321
    interface port-channel321
      switchport
      switchport access vlan 204
      flowcontrol send on
      vpc 321
    N7K-2# sh run int eth102/1/9
    interface Ethernet102/1/9
      switchport
      switchport access vlan 204
      channel-group 321
      no shutdown
    N7K-2# sh run int po321
    interface port-channel321
      switchport
      switchport access vlan 204
      flowcontrol send on
      vpc 321
    vPC status
    id   Port   Status Consistency Reason                     Active vlans
    321  Po321  up     success     success                    204            
    Scenario 1-Etherchannel only without protocol
    Both links are up, problem only happened when link to N7K-2 restart. If link to N7K-1 restart no problem.
    Scenario 2-Etherchannel with LACP
    Both physical links NOT up. Logs showing this:
    2013 Aug 20 17:04:31 N7K-1 %ETHPORT-5-IF_DOWN_ADMIN_DOWN: Interface Ethernet102/1/9 is down (Administratively down)
    2013 Aug 20 17:04:32 N7K-1 %ETHPORT-5-IF_ADMIN_UP: Interface Ethernet102/1/9 is admin up .
    2013 Aug 20 17:04:35 N7K-1 %ETHPORT-5-SPEED: Interface Ethernet102/1/9, operational speed changed to 1 Gbps
    2013 Aug 20 17:04:35 N7K-1 %ETHPORT-5-IF_DUPLEX: Interface Ethernet102/1/9, operational duplex mode changed to Full
    2013 Aug 20 17:04:35 N7K-1 %ETHPORT-5-IF_RX_FLOW_CONTROL: Interface Ethernet102/1/9, operational Receive Flow Control state changed to off
    2013 Aug 20 17:04:35 N7K-1 %ETHPORT-5-IF_TX_FLOW_CONTROL: Interface Ethernet102/1/9, operational Transmit Flow Control state changed to on
    2013 Aug 20 17:04:35 N7K-1 %ETHPORT-5-SPEED: Interface port-channel321, operational speed changed to 1 Gbps
    2013 Aug 20 17:04:35 N7K-1 %ETHPORT-5-IF_DUPLEX: Interface port-channel321, operational duplex mode changed to Full
    2013 Aug 20 17:04:35 N7K-1 %ETHPORT-5-IF_RX_FLOW_CONTROL: Interface port-channel321, operational Receive Flow Control state changed to off
    2013 Aug 20 17:04:35 N7K-1 %ETHPORT-5-IF_TX_FLOW_CONTROL: Interface port-channel321, operational Transmit Flow Control state changed to on
    2013 Aug 20 17:04:55 N7K-1 %ETH_PORT_CHANNEL-5-PORT_SUSPENDED: Ethernet102/1/9: Ethernet102/1/9 is suspended
    2013 Aug 20 17:05:13 N7K-1 %LACP-FEX102-5-LACP_SUSPEND_INDIVIDUAL: LACP port Ethernet102/1/9(0x1f650200) of port-channel port-channel321(0x16000140) not receiving any LACP BPDUs  suspending (individual) port
    Scenario 3-Etherchannel with LACP to single 3750 switch
    All working fine, fail over success as expected.
    N7k is using NX-OS 6.0(4)
    Anyone facing this issue?

    Hi,
    I had had this problem before.
    Please, put the following command, if in your server side is using LACP:
    interface Ethernet102/1/9
      switchport
      switchport access vlan 204
      channel-group 321 mode active
      no shutdown
    N7K-1# sh run int po321
    interface port-channel321
      switchport
      switchport access vlan 204
      flowcontrol send on
      vpc 321
    N7K-2# sh run int eth102/1/9
    interface Ethernet102/1/9
      switchport
      switchport access vlan 204
      channel-group 321 mode active
      no shutdown
    N7K-2# sh run int po321
    interface port-channel321
      switchport
      switchport access vlan 204
      flowcontrol send on
      vpc 321

  • Cisco Nexus 7010

    Hi,
    Can any one please let me know how to enable http/https access on cisco nexus 7010
    Regards
    Asif Naveed

    Following objects from conventional CISCO-PROCESS-MIB provides you details on CPU on devices:
    cpmCPUTotal5secRev     1.3.6.1.4.1.9.9.109.1.1.1.1.6
    cpmCPUTotal1minRev     1.3.6.1.4.1.9.9.109.1.1.1.1.7
    cpmCPUTotal5minRev      1.3.6.1.4.1.9.9.109.1.1.1.1.8
    Following document will be helpful as well:
    http://www.cisco.com/en/US/tech/tk648/tk362/technologies_tech_note09186a0080094a94.shtml
    As many MIBs are not completely implemented on NX-OS so there is one more MIB which can help, i.e CISCO-SYSTEM-EXT-MIB :
    cseSysCPUUtilization(1.3.6.1.4.1.9.9.305.1.1.1)
    Unlike the averaged values from CISCO-PROCESS-MIB, cseSysCPUUtilization returns an un-smoothed value and typically shows more erratic results. It only shares the the average utilization of CPU on the active supervisor. So usually it is recommended to use the CISCO-PROCESS-MIB, ie. cpmCPUTotal5secRev instead.
    -Thanks
    Vinod
    **Rating Encourages contributors, and its really free. **

  • Logging of commands on syslog server (Cisco Nexus 7010)

    Please help.
    How to set up logging of commands on syslog server ? (cisco nexus 7010)

    Hi Igor
    Nexus has internal accounting log: sh accouting log
    But it can be sent only to the accounting server, not to a syslog server.
    If you want - you man manually export it to some log.
    HTH,
    Alex

  • Nexus 1000v port-channels questions

    Hi,
    I’m running vCenter 4.1 and Nexus 1000v and about 30 ESX Hosts.
    I’m using one system uplink port profile for all 30 ESX Host; On each of the ESX host I have 2 NICs going to a Catalyst 3750 switch stack (Switch A), and another 2 NICs going to another Catalyst 3750 switch stack (Switch B).
    The Nexus is configured with the “sub-group CDP” command on the system uplink port profile like the following:
    port-profile type ethernet uplink
    vmware port-group
    switchport mode trunk
    switchport trunk allowed vlan 1,800,802,900,988-991,996-997,999
    switchport trunk native vlan 500
    mtu 1500
    channel-group auto mode on sub-group cdp
    no shutdown
    system vlan 988-989
    description System-Uplink
    state enabled
    And the port channel on the Catalyst 3750 are configured like the following:
    interface Port-channel11
    description ESX-10(Virtual Machine)
    switchport trunk encapsulation dot1q
    switchport trunk native vlan 500
    switchport trunk allowed vlan 800,802,900,988-991
    switchport mode trunk
    switchport nonegotiate
    spanning-tree portfast trunk
    end
    interface GigabitEthernet1/0/18
    description ESX-10(Virtual Machine)
    switchport trunk encapsulation dot1q
    switchport trunk native vlan 500
    switchport trunk allowed vlan 800,802,900,988-991
    switchport mode trunk
    switchport nonegotiate
    channel-group 11 mode on
    spanning-tree portfast trunk
    spanning-tree guard root
    end
    interface GigabitEthernet1/0/1
    description ESX-10(Virtual Machine)
    switchport trunk encapsulation dot1q
    switchport trunk native vlan 500
    switchport trunk allowed vlan 800,802,900,988-991
    switchport mode trunk
    switchport nonegotiate
    channel-group 11 mode on
    spanning-tree portfast trunk
    spanning-tree guard root
    end
    Now Cisco is telling me that I should be using MAC pinning when doing a trunk to two different stacks , and that each interface on 3750 should not be configured in a port-channel like above,  but should be configured as individual trunks.
    First question: Is the above statement correct, are my uplinks configured wrong?  Should they be configured individually in trunks instead of a port-channel?
    Second questions: If I need to add the MAC pinning configuration on my system uplink port-profile can I create a new system uplink port profile with the MAC pinning configuration and then move one ESX host (with no VM on them) one at a time to that new system uplink port profile? This way, I could migrate one ESX host at a time without outages to my VMs. Or is there an easier way to move 30 ESX hosts to a new system uplink profile with the MAC Pinning configuration.
    Thanks.

    Hello,
    From what I understood, you have the following setup:
         - Each ESX host has 4 NICS
         - 2 of them go to a 3750 stack and the other 2 go to a different 3750 stack
         - all 4 vmnics on the ESX host use the same Ethernet port-profile
              - this has 'channel-group auto mode on sub-group cdp'
         - The 2 interfaces on each 3750 stack are in a port-channel (just 'mode on')
    If yes, then this sort of a setup is correct. The only problem with this is the dependance on CDP. With CDP loss, the port-channels would go down.
    'mac-pinning' is the recommended option for this sort of a setup. You don't have to bundle the interfaces on the 3750 for this and these can be just regular trunk ports. If all your ports are on the same stack, then you can look at LACP. The CDP option would not be supported in the future releases. In fact, it is supposed to be removed from 4.2(1)SV1(2.1) but I still see the command available (ignore 4.2(1)SV1(4) next to it) - I'll follow up on this internally:
    http://www.cisco.com/en/US/docs/switches/datacenter/nexus1000/sw/4_2_1_s_v_2_1_1/interface/configuration/guide/b_Cisco_Nexus_1000V_Interface_Configuration_Guide_Release_4_2_1_SV_2_1_1_chapter_01.html
    For migrating, the best option would be as you suggested. Create a new port-profile with mac-pinning and move one host at a time. You can migrate VMs off the host before you change the port-profile and can remove the upstream port-channel config as well.
    Thanks,
    Shankar

  • Nexus 1000v - port-channel "refresh"

    Hi All,
    My question is, does anyone have any information on this 1000v command:
    Nexus-1000v(config)# port-channel internal device-id table refresh
    I am looking for a way for the port-channel interface to be automatically removed from the 1000v once the VEM has been deleted, currently the port-channel interface does not disappear when the VEM has been removed. This seems to be causing problems once the same VEM is re-added later on. Ports are getting sent into quarantine states and ending up in invalid states (eg. NoPortProfile state when there is actually a port-profile attached).
    Anyway, if anyone can explain the above command or tell me how to find out more, it would be great, I can't find it documented anywhere and the context-sensitive help in the NXOS is vague at best.

    Brendan,
    I don't have much information on that command, but I do know it wont remove any unused port channels.  They have to be manually deleted if they're no longer needed.
    The port Channel ID will remain even after a VEM is removed in case the assigned VEM comes back.  When a VEM is decommisioned permanently, I'll do a "no vem x" to also remove the Host entry for that VEM from the VSM.  This way the module slot # can be re-assigned to the next new VEM inserted.  After adding/removing VEMs just do a "show port-channel summary" to see any unused Port Channel IDs, and delete them.  It's a quick & painless task.
    I would hope this wouldn't be a common issue - how often are you deleting/removing VEMs?
    Regards,
    Robert

  • Nexus 6K: Port-Channel Load-Balance

    Hi all,
    I configured "port-channel load-balance ethernet source-dest-mac" on Nexus 6001. But when I use "show run all | in load-balance", it displays module 1 and module 2 are still using source-dest-ip for port-channel load-balance. And for command "show port-channel load-balance" and "show port-channel load-balance forwarding-path interface", it still shows switch using MAC for hash algorithm. The NXOS is 6.0(2)N1(2a).
    Does anybody know:
    -  What is the function of "port-channel load-balance ethernet source-dest-ip module" and in which situation this command will be effective?
    -  It shows "port-channel load-balance ethernet source-dest-ip module" command for both module 1 and 2. Module 1 is N6K Supervisor and module 2 is 4xQSFP Ethernet Module. Is it possible to set different load-balance algorithm  to these 2 modules?   
    # show run all | in load-balance
    port-channel load-balance ethernet source-dest-mac
    port-channel load-balance ethernet source-dest-ip module 1
    port-channel load-balance ethernet source-dest-ip module 2
    # show port-channel load-balance
    Port Channel Load-Balancing Configuration:
    System: source-dest-mac
    Port Channel Load-Balancing Addresses Used Per-Protocol:
    Non-IP: source-dest-mac
    IP: source-dest-mac
    # show port-channel load-balance forwarding-path interface port-channel 30 vlan 150 src-ip 172.25.228.6 dst-ip 172.25.226.97
    Missing params will be substituted by 0's.
    Load-balance Algorithm on switch: source-dest-mac
    crc_hash: 977 Polynomial: CRC10b        Outgoing port id  Ethernet1/2
    Param(s) used to calculate load-balance:
            seed: 0x701
            dst-mac:  0000.0000.0000
            src-mac:  0000.0000.0000
    # show module
    Mod Ports Module-Type                         Model                  Status
    1   48    Norcal 64 Supervisor                N6K-C6001-64P-SUP      active *
    2   10    Nexus 4xQSFP Ethernet Module        N6K-C6001-M4Q          ok
    Mod  Sw              Hw      World-Wide-Name(s) (WWN)
    1    6.0(2)N2(3)     1.0     --
    2    6.0(2)N2(3)     1.0     --

    Hi all,
    I configured "port-channel load-balance ethernet source-dest-mac" on Nexus 6001. But when I use "show run all | in load-balance", it displays module 1 and module 2 are still using source-dest-ip for port-channel load-balance. And for command "show port-channel load-balance" and "show port-channel load-balance forwarding-path interface", it still shows switch using MAC for hash algorithm. The NXOS is 6.0(2)N1(2a).
    Does anybody know:
    -  What is the function of "port-channel load-balance ethernet source-dest-ip module" and in which situation this command will be effective?
    -  It shows "port-channel load-balance ethernet source-dest-ip module" command for both module 1 and 2. Module 1 is N6K Supervisor and module 2 is 4xQSFP Ethernet Module. Is it possible to set different load-balance algorithm  to these 2 modules?   
    # show run all | in load-balance
    port-channel load-balance ethernet source-dest-mac
    port-channel load-balance ethernet source-dest-ip module 1
    port-channel load-balance ethernet source-dest-ip module 2
    # show port-channel load-balance
    Port Channel Load-Balancing Configuration:
    System: source-dest-mac
    Port Channel Load-Balancing Addresses Used Per-Protocol:
    Non-IP: source-dest-mac
    IP: source-dest-mac
    # show port-channel load-balance forwarding-path interface port-channel 30 vlan 150 src-ip 172.25.228.6 dst-ip 172.25.226.97
    Missing params will be substituted by 0's.
    Load-balance Algorithm on switch: source-dest-mac
    crc_hash: 977 Polynomial: CRC10b        Outgoing port id  Ethernet1/2
    Param(s) used to calculate load-balance:
            seed: 0x701
            dst-mac:  0000.0000.0000
            src-mac:  0000.0000.0000
    # show module
    Mod Ports Module-Type                         Model                  Status
    1   48    Norcal 64 Supervisor                N6K-C6001-64P-SUP      active *
    2   10    Nexus 4xQSFP Ethernet Module        N6K-C6001-M4Q          ok
    Mod  Sw              Hw      World-Wide-Name(s) (WWN)
    1    6.0(2)N2(3)     1.0     --
    2    6.0(2)N2(3)     1.0     --

  • Data Center Hall Temperature for Cisco Nexus 7010

    Hi,
    I Have a Nexus 7010 that sometimes raise an alarm about temperature thresholds that are being exceeded.... I was wondering if Cisco has a recommendation (or best practice) about the correct temperature that the Nexus need in the cold and hot hall of the data room. I know that the operative temperature of nexus is 0 - 40°C but i´m not sure if my halls are in the best temperature.

    Hi Salvador,
    As long as you keep your Data Center environment in this operative range your N7K will be fine.
    The usual is around 18°C and 24°C.
    Richard

  • Nexus 5k port channel

    I want to create a port channel on my nexus switch which will be connected to my server.
    will someone please share with me the configuration for the same ?

    Hi,
    From server side create LACP port-channel and same from switch end.
    Nexus-SW
    =======
    interface Ethernet1/1-2
      description [connection to SRV-01]
      switchport
      switchport access vlan 10
      channel-group 20 mode active
      no shutdown
    interface port-channel20
      description [connection to SRV-01]
      switchport
      vpc 20
      switchport access vlan 10

  • FI 6248 Nexus 5548 Port-channel problem

                       Hi all
    I have a strange behavior between 2 FI and 2 nexus 5k configured as VPC , From a remote location and from my desktop I can ping odd ip and not even , from an other desktop in the same LAN the reverse, for both the tracert are good.
    The only solution is to shutdown  ports 1/1-2 on nexus A or FI A and in that case both desktops can ping both IP.
    All seems OK, no log error , no error on interface , I give below some commands
    What thing to know is that the nexus b has a L3 card , not the Nexus A , In fact I am waiting for a spare L3 daughter card.
    On both NexusI have such configuration and status
    interface port-channel201
      description ucs-Fab-a
      switchport mode trunk
      switchport trunk native vlan 999
      spanning-tree port type edge trunk
      vpc 201
    UCSM-PARIS-A(SSI153000ST)
                           Eth1/1        129    S I s     UCS-FI-6248UP Eth1/11
    UCSM-PARIS-A(SSI153000ST)
                           Eth1/2        174    S I s     UCS-FI-6248UP Eth1/12
    sh port-channel summary
    201   Po201(SU)   Eth      LACP      Eth1/1(P)    Eth1/2(P)
    sh mac address-table dynamic | i 1010
    * 1010     0025.b5c9.481e    dynamic   0          F    F  Po201
    * 1010     0025.b5c9.481f    dynamic   10         F    F  Po201
    sh ip arp
    10.203.136.21   00:01:05  0025.b5c9.481f  Vlan1010
    10.203.136.22   00:12:43  0025.b5c9.481e  Vlan1010
    On both FI A have such configuration and status
    terface port-channel201
      description U: Uplink
      switchport mode trunk
      pinning border
      switchport trunk native vlan 999
      switchport trunk allowed vlan 1,104,999,1010-1013,1020-1021,1500-1502,1510-151
    2,1550-1552,1560-1561,1600-1602,1610-1619
      speed 10000
    sh port-channel summary
    201   Po201(SU)   Eth      LACP      Eth1/9(P)    Eth1/10(P)   Eth1/11(P)
                                         Eth1/12(P)
    sh mac address-table dynamic
    * 1010     0025.b5c9.481e    dynamic   0          F    F  Po201
    * 1010     0025.b5c9.481f    dynamic   0          F    F  Po201
    sh cdp nei
    E2RTR001(SSI1608085E)  Eth1/9          120     S I s       N5K-C5548UP   Eth1/1
    E2RTR001(SSI1608085E)  Eth1/10         120     S I s       N5K-C5548UP   Eth1/2
    E2RTR002(SSI16080F17)  Eth1/11         151     R S I s     N5K-C5548UP   Eth1/1
    E2RTR002(SSI16080F17)  Eth1/12         136     R S I s     N5K-C5548UP   Eth1/2
    Any ideas, A configuration I forgot on FI ?
    Regards .

    In fact in the probem I described the path is Esx -> FAB A - > N5K-A (for layer 2) -> N5K-B (for L3) -> routing to the LAN
    And what you told me is that such configuration is not supported with VPC configuration , so I need to wait to receive the L3 card for the N5k-A. and check later if I have the same problem.
    thanks

  • Monitoring optical level cisco nexus 7010, 5548.

    Good day!
    Please help me find oid for monitoring optical levels by snmp.

    Hi ,
    Have you tried to snmpwalk the entSensorValueTable
    (.1.3.6.1.4.1.9.9.91.1.1.1) from the CISCO-ENTITY-SENSOR-MIB
    It¹s indexed by entPhysicalIndex, so you¹ll need to snmpwalk the
    entPhysicalDescr (.1.3.6.1.2.1.47.1.1.1.1.2) to map the index in the above
    table to a name/entity indexed by the same # here.
    what is the equivalent CLI for the same ?
    Thanks-
    Afroz

  • Port-channel L2 problem with Fabric Interconnect and Nexus 7010

    Hi,
    i using port-channel from both fabric interconnect to N7k with 3 cables per Fabric Interconnect.
    but, my problem is when i creating port-channel, Fabric Interconnect don't support mode ON dan rate-mode share in Interface 10G Nexus 7010.
    I was trying :
    1. I using non dedicated port in Nexus 7010.
          - rate-mode share
          - channel-group 1 mode active
          - switchport mode trunk
    when i using this option, the port-channel in Nexus 7010 was suspended
    2. I using non dedicated port in Nexus 7010
         - rate-mode share
         - channel group 1 mode on
         - switchport mode trunk
    when i using this option, the port-channel in Nexus 7010 was came up, but in Fabric interconnect was failed.
    3. I using dedicated port in Nexus 7010
         - rate-mode share
         - channel group 1 mode active
         - switchport mode trunk
    when i using this option, the port-channel in Nexus 7010 was suspended
    4. I using dedicated port in Nexus 7010
         - rate-mode dedicated
         - channel group 1 mode active
         - switchport mode trunk
    when i using this option, the port-channel in Nexus 7010 was came up and running well.
    but, the problem is my costumer do not want using a dedicated rate-mode. if i using dedicated mode the only available port is 8 interfaces instead of 32 ports. i want to using rate-mode share in nexus 7010.
    is there any way to configuring port-channel using mode on in fabric interconnect ? i was trying using CLI to create port-channel in Fabric interconect but i cannot configure the channel group protocol.
    i attach the topology of N7K with Fabric interconnect.
    regards,
    Berwin H

    Hi Manish,
    the issue was solved, i was fix it last week.
    the solution is:
    i enable the license grace-priode (since my license is Enterprise so cannot create VDC) then i create a VDC (ex: VDC 2)  so i allocate the interface on all module
    /* Style Definitions */
    table.MsoNormalTable
    {mso-style-name:"Table Normal";
    mso-tstyle-rowband-size:0;
    mso-tstyle-colband-size:0;
    mso-style-noshow:yes;
    mso-style-priority:99;
    mso-style-qformat:yes;
    mso-style-parent:"";
    mso-padding-alt:0cm 5.4pt 0cm 5.4pt;
    mso-para-margin-top:0cm;
    mso-para-margin-right:0cm;
    mso-para-margin-bottom:10.0pt;
    mso-para-margin-left:0cm;
    line-height:115%;
    mso-pagination:widow-orphan;
    font-size:11.0pt;
    font-family:"Calibri","sans-serif";
    mso-ascii-font-family:Calibri;
    mso-ascii-theme-font:minor-latin;
    mso-fareast-font-family:"Times New Roman";
    mso-fareast-theme-font:minor-fareast;
    mso-hansi-font-family:Calibri;
    mso-hansi-theme-font:minor-latin;
    mso-bidi-font-family:"Times New Roman";
    mso-bidi-theme-font:minor-bidi;}
    N7K-M132XP-12 to VDC 2. after that i delete VDC 2 then all interface back to VDC 1 (default vdc). then i enable the rate-mode share in dedicated port and bundle into port-channel and its working.
    i dont know why it must move to VDC first then it will working, maybe cisco can explain the reasons.
    So here the result of my port-channel :
    SVRN7KFARM-HO-01# show port-channel summary
    Flags:  D - Down        P - Up in port-channel (members)
            I - Individual  H - Hot-standby (LACP only)
            s - Suspended   r - Module-removed
            S - Switched    R - Routed
            U - Up (port-channel)
    Group Port-       Type     Protocol  Member Ports
          Channel
    1     Po1(SU)     Eth      LACP      Eth1/1(P)    Eth1/2(P)    Eth1/3(P)
                                         Eth1/4(P)    Eth1/25(P)  
    2     Po2(SU)     Eth      LACP      Eth1/9(P)    Eth1/10(P)   Eth1/11(P)
                                         Eth1/12(P)   Eth1/26(P)  
    3     Po3(SU)     Eth      LACP      Eth1/17(P)   Eth1/18(P)  
    4     Po4(SU)     Eth      NONE      Eth10/32(P)  Eth10/34(P)  Eth10/35(P)
                                         Eth10/36(P)
    Thanks.
    Berwin H

  • Cisco Nexus 9300 Virtual Port Channel Support

    Hi,
    As I am new to Nexus 9300 and I was wondering if the switch may support virtual port channel (VPC)? I was wondering if there may be any feature matrix to compare it against the 9500/N7Ks/N5Ks
    Any suggestion is appreciated.
    Thanks.

    Hi Marvin,
    Appreciate for the information. I believe the customer is in the process of moving to ACI gradually however the setup I will be making will be classical ethernet setup which is similar to VSS setup whereby the N9300 would make use of VPC to connect to catalyst 3K/6K switch. I have illustrated it below for reference:
          Catalyst 6500 Non-VSS (Core)
          |----(VPC)---|
    N9300 ----- N9300   (Aggregation/Distribution)
          |----(VPC)---|
     Catalyst 3K switch (Access)
    Appreciate for clarrifiying the support for VPC for Nexus 9300 as I made a search on feature navigator for "Virtual Port Channel" which only listed the N7K platforms.
    Thanks.

  • Maximum number of interfaces in Port Channel on Nexus 5596

    Let me preface this by saying I am not a network expert....
    I noticed that our customer had configured a port channel on their Nexus 5596 comprised of 16 interfaces. I thought the maximum number of interfaces in a port channel was 8 interfaces? I see in the Nexus 7000 documentation that if you configure 16 interfaces, the remaining 8 will be in "hot standby." Is this the same behavior on the Nexus 5000 series?
    Thank you.

    Same behavior on the 5500 series and other Cisco switches like 3750, 3850 , etc..
    HTH

Maybe you are looking for

  • FCE 4 won't launch

    Ok, before anybody lectures me, I know that an eMac is not supported for FCE 4 because of the graphics card. But it works for what I need to do, which is some DV capture and simple editing. It should also give me the ability to look at my friend's FC

  • Advice on importing a 250 page document into indesign 5.5

    Hi, My job needs me to put together a fairly large well-designed 250 page book. I currently have the document in a 2007 Miccrosoft Word file. I was trying to read on the Adobe website, as well as on the forums, but I am hoping to get some additional

  • Translation of the French

    The translation of the French functions is it correct. It y in A much which does not function. Somebody can it to help me?

  • Need to restrict Print out in back Ground Job

    Hi all, The T.Code COHVPI  will use for mass processing of Relealse process order. It the same time it will give print out for all process orders which are successfule change status to REALEASE status.Presently it is running forground Job , it is giv

  • Re:SAP GRC 10.o

    Hi All, I am new to GRC 10.o, Can Any one suggest me to Start the GRC 10.o implementation preparation please.