Cutomer Exit variable problem

Hi,
I have created user exit variable based on the calmonth user exit variable.
The problem is I am unable to fetch the data for YTD values.
ZVCS_USPER  ---> other user exit varible  EX: 002.2011
Input for ZVCS_YTDUSPER Variable
IF i_step = 2.
case i_vnam.
    when 'ZVCS_YTDUSPER'.
      LOOP AT i_t_var_range INTO loc_var_range
                            Where vnam = 'ZVCS_USPER'.
       concatenate  Loc_var_range-low+4(3) '001'  into LS_RANGE-low.
      LS_RANGE-High = Loc_var_range-low+0(7)
      LS_RANGE-SIGN = 'I'.
      LS_RANGE-OPT = 'BT'.
      APPEND LS_RANGE TO E_T_RANGE.
ENDLOOP.
     ENDCASE.
ENDIF.
Could you please verify the code and let me know the issue....
Thanks,
Gana

answered.

Similar Messages

  • Cutomer exit variable

    Hi all,
    I need to use a date field in variable screen.
    My problem is that the field is in day format and I want to allow the user to enter a month (i.e.: 05.2010 instead of 01.05.2010-31.05.2010).
    I cannot use 0CALMONTH because it is populated with another date.
    Is it possible?
    Regards,
    Hagit

    Hi,
    you can create a variable to enter a value and then fill the exit variable via coding from the data entered in the input variable. You need to take into account i_step in the exit.
    Siggi

  • Problem in transporting the Customer exit variable

    Hi all,
    i have careated a variable to capture the current date in my report, with the processing type, Customer Exit. and, its getting populated fine in my DEV environment. basically, i have to compute the number of days, in which net due date is being compared to the current date.  when i transport this to the QA environment, the values for number of days is gettting some junk value, wherein in DEV its showing the exact values. It seems i have to take cetain measures in transportation of the Customer Exit.
    please advice.
    Thanks in advance
    Sneel

    Hello ,
               In the Quality after you run the report check in the layout option>display text elements> variables and check what value is displayed for the use exit variable , if it is correct then problem may be in the selection you gave when you run the report if the user exit variable value is wrong , then set a break point in the code and run the report from rsrt and check where the error is.
    hope it is clear
    assign points if useful

  • Problem with customer exit variable that is input ready as well

    Hello all,
    I'm facing an issue with a customer exit variable that again has been defined as input ready. I'm not sure why it is working incorrectly and I#m wondering if this is a bug or if I do s.th. stupid.
    The problem is that in the exit program ZXRSRU01 this varibale does not go into the program code I have prepared for this variable. I have added entry points for all three i_step values 1,2,3, but the code will never be touched and in debugging I can see that it simply pypasses the code for this variable.
    I have tried to enter a value or to leave it blank, no difference.
    When I run another test by just using a customer exit variable w/o input ready capability, then I have no issue, the exit does exactly what I have coded.
    Does this mean, that a customer exit variable along with input readiness dows not work ?????
    You may ask why I need this variable. Well, my intention is to use the input value of this variable A to derive other values for a complete different variable B. Afterwards I want to erase the input given into variable A to have it blank.
    Any comments are appreciated
    Thanks

    Hi Heiko,
    I assume A & B variables are defined on different Characteristics. If you wish to derive B based on A, you can create the Query Characteristic Restriction on B & have a dummy RKF restricted on A whose processing is by Manual Input; where processing of B is by Customer Exit. In istep 2 you can check for B, read A & derive B. There would not be a need to blank out A since the Query would not be restricted on A - you can hide the dummy RKF from showing in the output. Just a thought.
    --Priya

  • Numeric value variable problem with user exit

    Dear experts,
    I've created a variable (numeric value, user exit) and I want to get the value of variable from an user exit.
    Actually, I want to convert "0calyear" to a number to be albe to calculate (multiplying, dividing etc).
    If there is a possible solution only in FOX, the solution will be the best. However I couldn't find anything.
    So, the next solution I am trying is user-exit. But I am in stuck here.
    The problem is that I have no idea whether the numeric value variable has any sturcture like other variables(char. value) or not. If yes, what structure it has?
    I know, the characterisc value variables have the structure as blow,
        ls_varsel-chanm =
        ls_varsel-seqno =
        ls_varsel-sign  =
        ls_varsel-opt   =
        ls_varsel-low   =
    I've tried several times with the same way like above, but it doesn't work when I call the variable in "BPS0" or "UPSPL".
    How can I solve it? Please let me know.
    I am using SEM_BW 4.00.
    Many Thanks.
    Bruce

    Hi Ravi,
    Sorry, there's a correction. <b>var2 is used for getting the first month of the year selected by the user in var1</b>. If the user doesn't enter a value for var1, then var2 should take first month of current year from var1 which has by default last month of current year (populated in i_step1 from sy-datum). The user can select the value of var1 according to his requirement. Then var 2 should get first month of the year selected. That's why I'm using two exit variables.
    It works fine during the initial run of the query. But when the user clicks on the variable button in the toolbar and executes the query, var1 is not being displayed and an error message <i>No value could be determined for var2</i> is shown. All other variables used in the query are displayed except var1.
    Krzys, Is the option <i>Can be changed in Query Navigation</i>  available for Exit variables. I'll check that and get back to you.
    Boujema, Thanks for the OSS note.
    Thanks
    Hari

  • Problem with Bex Customer Exit Variable

    Hi Friends,
    I have a customer exit variable which is getting filled based on the User Input.  I have written the code inside the If condition checking i_step = 2. The code is working as required.
    But the problem is when I try refreshing the query or change the user variable selection, the Customer exit variable is not changing.  I tried to debug the code and realized that the  values for the exit variable based on the previous selection is not cleared and the i_step = 2  is not being executed for the variable.
    While I close and reopen the query, the code is working fine.  
    Does anyone know why this is happening?  Please suggest..
    Thanks in advance..
    Regards,
    Priya

    Hi Binu,
    Here is the code sample.  I am trying to populate the month based on the input Week number '0I_WEKIN'
    .  For eg.  If I give 37.2011, the month value should be 08.2011.  If I give 39.2011, month should be 09.2011.
      WHEN 'ZC_MONTH'.
        IF i_step = 2.     "after the popup
            READ TABLE i_t_var_range INTO lw_var_range WITH KEY vnam =
        '0I_WEKIN'.
           IF lw_var_range-high IS NOT INITIAL.
              l_week  = lw_var_range-high.
              l_week = l_week - 3.
              CALL FUNCTION 'WEEK_GET_FIRST_DAY'
                EXPORTING
                  week = l_week
                IMPORTING
                  date = l_date.
              lw_range-low = l_date+0(6).
            ENDIF.
            lw_range-sign = 'I'.
            lw_range-opt  = 'BT'.
            APPEND lw_range TO e_t_range.
        ENDIF.
    Regards,
    Priya

  • Problem with BW exit variable on range of dates

    Hi everyone:
    I have a problem with exit variables in BW, the scenary is following:
    I need to generate a ratio MTD (month to date, i mean, first day of the month to actual date), for this, I enter a date by keyboard, for example 31.12.2010 and BW must return the range 01.12.2010 - 31.12.2010. The problem is what BW returns: 31.12.2010 - 31.12.2010, i mean, repeats the same date entry by keyboard.
    For this porpuse I have a variable of interval type called "ZCALDAY" on infoobjeto 0CALDAY, and  exit variable of interval type called "ZRANGE", the code in CMOD is the following:
    DATA: L_RANGE         TYPE RRS0_S_VAR_RANGE,
                L_P_RANGE   TYPE RRS0_S_VAR_RANGE,
                L_S_RANGE   TYPE RSR_S_RANGESID.
    when 'ZRANGE'.
         BREAK-POINT.
         IF I_STEP = 2.
           CLEAR l_s_range.
           READ TABLE i_t_var_range INTO loc_var_range WITH KEY vnam = 'ZCALDAY'.
           CONCATENATE loc_var_range-low(6) '01' INTO l_s_range-low.
           l_s_range-high = loc_var_range-low.
           l_s_range-sign    = 'I'.
           l_s_range-opt     = 'BT'.
           APPEND l_s_range TO e_t_range.
        ENDIF.
    I doing Something wrong with the variables definition or on the  code??
    I hope you can help me....
    Best regards!!!!
    Cesar.

    Thanks!!
    I think the problem is other, I check the RSRT transaction and the range is calculated ok, i mean, the range generated is 01.12.2010..31.12.2010.
    But the query does not show the data corresponding. the query shows the values of the day 31.12.2010.
    The interval are not restricting the key figure...
    I used the variable exit "ZRANGE" on the key figure restriction and the variable ZCALDAY in the filters section.
    Maybe, the variable definition is wrong (variable ZCALDAY and exit variable ZRANGE)
    Thanks!!!

  • Problem with customer exit variable on date range

    Hi All,
    I have customer exit variable on date range. In the selection screen it has to give the week range  as a default (05/21/2009 to 05/27/2009).
    Earlier its working fine and from yesterday onwards it is not working properly. yesday onwards default date range was not displaying in selection screen.
    Wht would be the problem.
    Thanks in Advance

    Hi Ashish,
    I checked every thing what u told earlier. Every thing is fine.
    And another thing is
    I have routine in infopackage level. Since day before yesterday it was working fine and yesterday onwards it was not working.
    Eg: budat will take the data based on routine for the week. But yesterday onwards it is not picking up the data.however I have the data in datasource for the week.
    Wht would be the problem. I debuged the code and its working fine.
    Sekhar

  • Problem with customer exit variable in BeX Query

    Hi All,
    We have created a customer exit variable in a query and populated with few patterns in customer exit.
    My query has to bring all the records where the address line is containg the patterns passed through customer exit. Here the query is not working as expected.
    It is bringing the values where the address line is exactly same as the pattern and not bringing the records where the pattern is part of the address line.
    For example: Pattern passed in customer exit = 'HOSPITAL'
    The record where address line = 'HOSPITAL' is shown in the rpeort, where the record with address line = 'HOSPITAL ROAD' is not shown in the report.
    I would appreciate your help on this.
    Regards,
    Rakesh

    Hi Diogo,
    Below is the code I am using in the customer exit.
    SELECT * FROM zae_tt_pbuild INTO TABLE gt_pbuild.
          IF sy-subrc = 0.
            LOOP AT gt_pbuild INTO gs_pbuild.
              CONCATENATE '*' gs_pbuild-pbuild '*' into lv_pattern.
              ls_range-low = lv_pattern.
              ls_range-sign = lc_sign_i.
              ls_range-opt = 'CP'.
              APPEND ls_range TO e_t_range.
              CLEAR: ls_range,
                     lv_pattern.
            ENDLOOP.
          ENDIF.
         ENDIF.
    I have tried using '%' instead of '*' aswell but the result is same.
    Thanks,
    Rakesh

  • Problem with populating exit variable

    Hi,
    Im reposting this thread which is already in another section.
    I have a requirement as follows:
    There are 2 info objects for Start& End Periods of project.
    There is another Keyfigure(number of months) which is populated by calculating the difference of Start & End periods.
    Now, the filtering criteria would be Start period, End period and number of months.
    When the user enters the Start and End periods of the project and also the number of months, the system shoudl display all the projects matching the above filtering criteria.
    Eg:
    Project1: Start period : 01.2009
    End period : 06.2009
    Number of months : 6
    Project2: Start period : 02.2009
    End period : 04.2009
    Number of months : 3
    Project3: Start period : 03.2009
    End period : 05.2009
    Number of months : 3
    Project4: Start period : 05.2009
    End period : 07.2009
    Number of months : 3
    Project5: Start period : 05.2009
    End period : 09.2009
    Number of months : 5
    Now if the user enters the following the filtering criteria:
    Start period: 01.2009
    End period: 12.2009
    Number of Months : 3,
    the system should display only project2,project3,project4.
    Any thoughts on how to achieve this using an Exit variable? Because the variables Start and End periods are created on 2 seperate info objects.
    Thanks
    Shyam

    Hi Shyam,
               Check this url.....
    http://www.sd-solutions.com/documents/SDS_BW_Replacement%20Path%20Variables.html
    Hope this will suits for u'r requirement.
    Regards,
    Vijay.

  • Problem with User exit variable

    We're using an user exit variable (var2) for YTD calculation (For getting the first month of current year). It gets value from another exit variable (var1) which has by default value last month of current year(populated in I_step1 from sy-datum). If the user wants he can change the default value of var1. It works fine when the query is executed the first time. But if the user calls the variable screen again, the variable screen does not show var1 in the popup and the user gets an error message that no value could be determined for var2. How can this issue be resolved or is there any other method to satisfy this requirement.
    Your help would be appreciated and rewarded.
    Thanks & Regards
    Hari

    Hi Ravi,
    Sorry, there's a correction. <b>var2 is used for getting the first month of the year selected by the user in var1</b>. If the user doesn't enter a value for var1, then var2 should take first month of current year from var1 which has by default last month of current year (populated in i_step1 from sy-datum). The user can select the value of var1 according to his requirement. Then var 2 should get first month of the year selected. That's why I'm using two exit variables.
    It works fine during the initial run of the query. But when the user clicks on the variable button in the toolbar and executes the query, var1 is not being displayed and an error message <i>No value could be determined for var2</i> is shown. All other variables used in the query are displayed except var1.
    Krzys, Is the option <i>Can be changed in Query Navigation</i>  available for Exit variables. I'll check that and get back to you.
    Boujema, Thanks for the OSS note.
    Thanks
    Hari

  • Problem with customer exit variable

    HI i have created a customer exit variable to rread a table based in user input and pass it to my variable , every thing works fine but i get a waring message in my WAD saying
    RANGE-LOW for customer exit variable ZVSO_PRM corrected to #   BRAIN  746
    Does any one have any idea why is it comming
    my code is as follows
    WHEN 'ZVSO_PRM'.
    IF I_STEP = 2.
    DATA: BEGIN OF ZPROD_MODEL OCCURS 0,
    I_PROD LIKE ZCURR_PM_T-/BIC/ZPRODMOD,
    END OF ZPROD_MODEL.
    DATA: BEGIN OF ZREGIO_TABLE OCCURS 0,
    REGION LIKE ZCURR_PM_T-/BIC/ZREGION,
    END OF ZREGIO_TABLE.
    LOOP AT I_T_VAR_RANGE INTO LOC_VAR_RANGE
    WHERE VNAM = 'ZREG02'.
    CLEAR L_S_RANGE.
    ZREGIO_TABLE = LOC_VAR_RANGE-LOW.
    APPEND ZREGIO_TABLE.
    ENDLOOP.
    LOOP AT ZREGIO_TABLE.
    SELECT /BIC/ZPRODMOD FROM ZCURR_PM_T INTO TABLE ZPROD_MODEL WHERE /BIC/ZREGION = ZREGIO_TABLE-REGION.
    APPEND ZPROD_MODEL.
    ENDLOOP.
    SORT ZPROD_MODEL.
    CLEAR L_S_RANGE.
    LOOP AT ZPROD_MODEL.
    L_S_RANGE-LOW = ZPROD_MODEL-I_PROD.
    L_S_RANGE-SIGN = 'I'.
    L_S_RANGE-OPT = 'EQ'.
    APPEND L_S_RANGE TO E_T_RANGE.
    ENDLOOP.
    ENDIF.

    Could it be that the code doesn't find any value in ZCURR_PM_T table for the specified input region?

  • Error in customer exit variable

    Hi All,
    My requirement is end user will enter fiscal year and in report out put I need to display fiscal year periods.
    For this I have created two variables
    1.Fiscal year-Manual Input/Default value-Single value-Mandetary-Variable is ready for input.
    2.FiscalyearperiodCustomer ExitInterval-Optional
    DATA : fiscyear1 TYPE numc4,
          i_fiscper_high TYPE /bi0/oifiscper.
    DATA: datein LIKE  sy-datum .
    CMOD Code is as below
    CASE i_vnam.
    WHEN  'ZFISCVAR'.
        LOOP AT i_t_var_range INTO loc_var_range
                             WHERE  vnam = 'ZFISCYER'.
          CLEAR l_s_range.
          fiscyear1 = loc_var_range-low(4).
          CONCATENATE fiscyear1 '001' INTO i_fiscper_high.
          l_s_range-low = i_fiscper_high.
          l_s_range-high = i_fiscper_high.
          l_s_range-sign = 'I'.
          l_s_range-opt  = 'BT'.
          APPEND l_s_range TO e_t_range.
        ENDLOOP.
    But we are getting error after entering fiscalyear
    error message --Value 2009001 for uesr exit variable xxxx is invalid.
    Regards
    Albaik

    Hi All,
    Below is the code and there is no problem with code but there was some problem with Fiscal year varient and solution is we went to source system -right click-Transfer global settings---- and maintained  Fiscal year varient 
    DATA: l_s_range TYPE rsr_s_rangesid.
    DATA: loc_var_range LIKE rrrangeexit.
    DATA: datein LIKE  sy-datum .
    DATA: L_S_RANGE_2 TYPE RSR_S_RANGESID.
    DATA : I_FISCPER_HIGH TYPE /BI0/OIFISCPER ,
           I_FISCPER_LOW TYPE /BI0/OIFISCPER.
    DATA : FISCYEAR1(4), FISCYEAR2(4),CALMONTH TYPE /BI0/OICALMONTH .
    WHEN  'ZFISPERIOD'.
        LOOP AT I_T_VAR_RANGE INTO LOC_VAR_RANGE
                             WHERE  VNAM = 'ZFISYEAR'.
          CLEAR L_S_RANGE.
          FISCYEAR1 = LOC_VAR_RANGE-LOW(4).
          CONCATENATE FISCYEAR1 '001' INTO L_S_RANGE-LOW .
             L_S_RANGE-SIGN = 'I'.
          L_S_RANGE-OPT  = 'EQ'.
          APPEND L_S_RANGE TO E_T_RANGE.
        ENDLOOP.
    ENDCASE.

  • Default value of BeX customer Exit variable not Displayed in WeBI??

    Hello Experts,
    We are stuck with a problem where WeBI report is created on top of BeX query and we are not able to see the default value of Bex Customer exit variable in WeBI run. Here is the complete scenario:
    1. One restricted KF is created in BeX, restricted with Customer exit variable on net Due date. And this variable is mandatory, ready for input, and Default value in calculated is user exit as current Week's Monday.
    2. So, by default KF data should be restricted to Monday of current week, if user does not change this value.
    3. Now, WeBI report is created on top of this Bex query, and all is working fine, i.e. we are getting variable as Prompt in WeBI, but Default value is not shown while Running the Webi Report.
    So, need your inputs on the same, if default values from BeX in WeBI is supported or not? If yes, why this is happening, and how to resolve it?
    Please notice, the restrcition is in KF only, it is not a separate restrcition on Net Due date in Filter area or in Defualt area of BeX
    and we are on SAP BW 7.1 and BOXI 3.1 SP4.
    Regards,
    Vipul
    Edited by: VIPUL GOYAL on Nov 23, 2011 9:44 PM

    Hi,
    See 1285993 - Support of Customer Exit Variables from BEx query into WebIntelligence via OLAP universe
    WebI will prompt when executed, but the default values calculated by the user exit  - do not appear.
    Note: If the BEx variable has property 'ready for input' set / enabled, then its WebI prompt shows ok, but no default value appears.
    Cause
    This behaviour expected 'by design' (in the context of the product's current limitations) as explained in the online guide below:
    Please refer to Chapter 7, page 44, document link here: http://help.sap.com/businessobject/product_guides/boexir3/en/xi3_sap_olap_universes_en.pdf
    Characteristic variable > processing type > Customer Exit  is "Supported, without user entry"                                                                               
    -->  This should be understood as meaning "User will not be shown a prompt"
    regards,
    H

  • How to select several values from a user exit variable in a planning folder

    Hello,
    I have created a user exit variable for limiting the values only to which the user need to access.
    For a simulation part, it is then necessary for him to select several values from these values (not only one, and not all)
    But It seems in this case the user has only two possibilities :
    - keep all the values without any restriction
    - restrain the selection to only one value.
    It seems possible for the user to access to a multiple choice window, but this possibility doesn't seems to work : in all tests we did, only the first value was taken into account by BPS.
    If this method is not good do you know an other manner to permit the user to choice several values amongst a set of pre-selected  (because the original set is too important) values ?
    Thanks for your help.

    Hi Mayank,
    Thanks for your response, but I don't think it corresponds to my problem.
    I my case, I use a user exit variable to filter some data. It seems BPS offers the possibility to the user to select several values amongts the pre-selected values presented by the user exit variable, but it doesn't work. We can use a popup in which we enters the required values, but in final, only the first value is taken into account.
    I don't know if it is due to a BPS bug or if it is not a good solution in regard to BPS philosophy. In this case, the concerned caracteristic isn't in the header but in lead columns.
    I must present a solution to my client next monday, so I have not enough time to open an OSS message.
    An alternate solution should be interesting too.
    My need is to present to a user a selection of values amongst all values from an infoobject (the user exit variable seemed to be a good solution) and the user must have the possibility to select some values amongst these as filter.
    Regards