Data Acquisition Solution for Measurement of Temp,V,I,P,Q,PF,f

Dear All,
I am facing one problem in selecting the Hardware,can anybody support me,
This is regarding DAQ Solution(cFP) for Measurement of Temperature,Voltage,Current,Active Power,Reactive Power,Power Factor and Frequency for a Motor.
Requirement is that, Measurement and Monitoring of Temperature,Voltage,Current,Active Power,Reactive Power,Power Factor and Frequency for a Motor
1)12 RTD Inputs(PT 100 Sensors)
2)3 Current(From 3 CT's) ,3 Voltage(From 3 PT's) [From these 6 Parameters,Active Power,Reactive Power,Power Factor,Frequency we have to derive ]
 Hardware which i have selected is attached,please find the attachment..
RTD Module which i have selelcted is ok,but i have one doubt in AI Module Selection,
I selected AI 100 Module(8 Channel(Both V,I).12 bit,360 S/s[in this i have one doubt,i.e.360 Samples that to per channel or 360 Samples per 8 channels?) for taking 3 Voltage Signals from PT's and 3 Current Signals from CT's)
If we install and take signals from Motor,in reality harmonics(Max if we consider 8th Harmonic Components [8*50=400 Hz will be signal Freq]) will come into picture,
For finding frequency(From V,I wave shapes),atleast (5 Fs i.e.5*400=2kS/s i have to take right,correct me sir if i am wrong..)
Why we want this system is,currently,we are using Yokogava Power Analyzer for finding Voltage,Current,Active Power,Reactive Power,Power Factor and Frequency,But RTD it cant..,So we need total System with RTD SIgnals and above parameters to be monitored in a host PC without any Power Analyzer,i.e.our measurement system should be independent of Yokogava Power Analyzer.Again one problem is that Yokogava is giving Accuracy 0.02% in the measurement of Power and what about the accuracy of our system and for this,which Module shall i go for?)
Regards,
Bujjin
Attachments:
cFP System Configuration.JPG ‏141 KB

Hi wayne.C,
Thank you very much for your reply,
Actually Interfacing the instrument for Power and remaining using Compact DAQ is also one more solution as u told,
but problem here is that,we are always dependent on the instruemnt.So i am looking for common Hardware platform
which will server both the purposes,and obviously,i will go for cRIO Solution,as sampling rate will be higher,
Thanks and regards,
Bujjin

Similar Messages

  • Does anyone have a data recovery solution for recovering photos lost after ios8 install?

    Does anyone have a data recovery solution for retrieving lost photo stream photos after installing ios8 on iphones and ipads?

    Does anyone have a data recovery solution for retrieving lost photo stream photos after installing ios8 on iphones and ipads?

  • I want to acquire data for multiple channels using PCI 6120 that works on traditional DAQ. I cannot access more than one channel, can someone help me or if someone has data acquisition vi for PCI 6120, please send me over . Thanks

    I have PCI 6120 card and I want to acquire data for more than one channels. I'm using traditional DAQ to get it. But it does not work for more than one channels. If someone has a data acquisition vi for PCI 6120. Or some suggestion how to aquire data please let me know.
    Thanks

    Hello DSPGUY1,
    You can definetly acquire from several channels. For your convenience, I have appended below the content from help that tells you how to configure it:
    "channels specifies the set of analog input channels. The order of the channels in the scan list defines the order in which the channels are scanned during an acquisition. channels is an array of strings. You can use one channel entry per element or specify the entire scan list in a single element, or use any combination of these two methods. If x, y, and z refer to channels, you can specify a list of channels in a single element by separating the individual channels by commas, for example, x,y,z. If x refers to the first channel in a consecutive channel range and y refers to the last channel, yo
    u can specify the range by separating the first and last channels by a colon, for example, x:y."
    Hope this help.
    Serges Lemo
    Applications Engineer
    National Instruments

  • Data Selection option for Measures only?

    Hi All I have Data Source with 3 dimenstion and few measures.  I see that We can pick measures to dispaly,, but can i also pick dimenstion to show on horizonatal a-axis ? In screenshot below, I would like to pick one domension for chart A and pick 2nd dimension for chart B.

    It's clear, but the selection you are showing above is only to bind measures.
    Why not use a filter panel, dimension panel, etc. to filter?

  • Data storage solution for SAP BO

    Hello,
    Is there a storage platform that SAP prefers for Business One SQL databases? For example, Storage Area Networks? Some big storage Vendors are HP, EMC, is there a preference on which vendor and which product?
    I would appreciate it if you could share any of your experience on this topic. Thanks.
    Yi

    Hi Yi,
    I suppose this forum may not be the right place for this question since it is mostly about the SAP Business One SDK and related questions.
    I propose that you contact your SAP sales representative who should forward you accordingly - or give you the information you are asking for.
    I remember having heard about special offerings from hardware vendors for B1 partners customers, but I don't know about any recommendation.
    If you would like to get recommendations from other partners or customers, I would suggest that you ask the question in the SAP community forum (www.sap.com/community) or the SAP Business One forum on Channel Partner Solution Network (CPSN): http://cpsn-channel.sap.com/businessoneforum
    HTH,
    Frank
    Message was edited by: Frank Moebius

  • NI Data Acquisition stuff for sale on Ebay

    I'm sorry if this offends any of the loyal readers of this group, but I
    didn't know where else to post this type of message.
    I have a NI DAQ-1200 for sale,
    http://cgi.ebay.com/aw-cgi/eBayISAPI.dll?ViewItem&item=142689200
    And also a 6810 serial data analyzer;
    http://cgi.ebay.com/aw-cgi/eBayISAPI.dll?ViewItem&item=142692934
    Thanks
    Sent via Deja.com http://www.deja.com/
    Share what you know. Learn what you don't.

    BEFORE you erase your iPhone 4, turn off FaceTime, iMessage & delete the iCloud account. After doing that, then erase the phone. If you fail to do so, your phone's IMEI number will still be associated with these services, even after you erase.

  • Strain gauge data acquisition

    Hi,
    Carried out first test for my data acquisition project for uni today. The general basic operation is I am carrying out a test on a super duplex steel tube. A new load is applied every 30 seconds and the program should record when the change in strain occurs which is then plotted on a table in an excell file. Some slight issues that I was hoping someone could maybe explain to me...
    1) get a negative value. "-2.107" unsure how to solve this. Have swapped wires around and no luck. Not sure if maybe he filter in my lab view is causing problems as I get an error with it. Problems with differential amplifier maybe?
    2) I wanted my program to plot ten results before save to a file. However it only takes one value and then saves. This means to get the next value when a new load is applied I have to save to a new document.
    I will post the actual program soon. Any ideas help would be much appreciated.
    Cheers
    Mike.

    Hi there,
    I've had a bit of a look into your code, and have modified it a bit to try better understand it. I'm not quite sure what's happening to give you negative results out of your strain analysis, but I think I may have picked up on some other issues.
    I've commented the changes I've made, but in summary:
    1) Removed sequence structure and enforced dataflow with error line
    2) Modified the DAQ section to just a random number generator for the sake of testing.
    3) Set data feed into excel section to indexing output rather than last value
    4) set iteration count of the for loop to address 10 strain measurements out of the array
    5) Changed text file logging to "open or create" to avoid errors which might occur if the file already exists during multiple runs - but this would depend on you wanting to write to the same file each time
    Note: In your for loop, if your attempting to relate the loads in the first column to your last 10 strain measurements, then this would be an incorrect way to go about interacting with the listbox. Please see this example which demonstrates how to address items in a listbox: https://decibel.ni.com/content/docs/DOC-5808
    Attached is the edited/commented vi - I hope this helps in some way and I haven't misunderstood! I'll have another think about the negative values issue..
    Attachments:
    Strain Gauge Edit.vi ‏124 KB

  • Data Recovery Software for MBP

    Apparently I have trashed the directory on my FW 160GB Maxtor External drive. "Unable to read disk". (It is a drag since it happened just as I was getting my brand new MBP system up! Oh well!)
    My research has not uncovered a suitable disk repair/data recovery solution for the new iMac (Intel-based). Does anybody know of one? The best one?

    Other than Disk Utility (Utilities folder) there are two commercial products: TechTool Pro 4.5.2 (www.micromat.com) and Drive Genius 1.5.1 (www.prosofteng.com.)
    Try DU, it's pretty good unless the directory is too badly trashed to be repaired.
    For data recovery there's Data Rescue II (www.prosofteng.com) and File Salvage (www.subrosasoft.com.)
    Why reward points?(Quoted from Discussions Terms of Use.)
    The reward system helps to increase community participation. When a community member gives you (or another member) a reward for providing helpful advice or a solution to their question, your accumulated points will increase your status level within the community.
    Members may reward you with 5 points if they deem that your reply is helpful and 10 points if you post a solution to their issue. Likewise, when you mark a reply as Helpful or Solved in your own created topic, you will be awarding the respondent with the same point values.

  • Descargar toolkit Q2-USB Data Acquisition Device

    Saludos comunidad:
    ¿Alguien tiene información o sabe como conseguir el driver y el toolkit para labview  y windows 7 del dispositivo "Q2-USB Data Acquisition Device" de Quanser, de forma gratuita?, pues solo lo necesito para este software y no el paquete completo.Ademas, el paquete de instalación que poseo sol sirve pra windows XP y labview 2012.
    cualquier ayuda se los agradeceria

    Saludos cristian.ccl,
    Gracias por utilizar los Foros de Discusión de National Instruments, estuve investigando un poco sobre tu consulta, lamentablemente no logre encontrar ningún driver gratuito para esta tarjeta, así bien te comento que para utilizar esta tarjeta con LabVIEW es necesario que cuentes con el Add-On Rapid Control Prototyping Toolkit para LabVIEW de Quanser, el cuál podrás encontrar en el siguiente enlace:
    Rapid Control Prototyping Toolkit - Quanser:
    http://sine.ni.com/nips/cds/view/p/lang/en/nid/211216
    Lamentablemente este Add-On no ofrece un periodo de evaluación, sin embargo te comparto un getting started de Quanser para utilizar esta tarjeta en LabVIEW esperando que sirva como punto de inicio:
    Quick Start Guide Q2-USB Data Acquisition Device for LabVIEW:
    www.quansershare.com/Home/Search?contentID=94
    Una posible opción sería comunicarte con el dispositivo en RAW Mode, los siguientes links pueden serte de utilidad:
    http://www.ni.com/tutorial/4478/en/
    How Can I Communicate With a Device Using NI-VISA USB RAW Mode?:
    http://digital.ni.com/public.nsf/allkb/E3A2C4FE42D7ED0D86256DB7005C65C9
    USB Instrument Control Tutorial:
    http://www.ni.com/tutorial/4478/en/
    Sin embargo, francamente creo que la mejor opción sería que utilizaras el Add-On existente, ya que además del driver, también cuenta con VI's bastante interesantes y que seguramente de serán de utilidad para tu aplicación. Otra posible alternativa sería contactar directamente a Quanser para confirmar si cuentan con algún driver gratuito:
    Technical Support Request:
    http://www.quanser.com/forms/techsupport.aspx
    Saludos cordiales.
    David P.
    National Instruments
    Applications Engineer
    www.ni.com/soporte

  • Lenovo NeXtScale N1200 Enclosure is a customized solutions for your applications

    QuestionDo you need a customized solutions for your applications?
    AnswerLenovo NeXtScale N1200 Enclosure is a customized solutions for your applications that can be configured to meet your specific business needs. Lenovo NeXtScale N1200 Enclosure is the best solution for optimum compute power, GPU acceleration, maximum compute power, GPU or coprocessor and storage with the right I/O and networking. Since the NeXtScale platform is optimized for standard racks, it allows the mixing of high-density NeXtScale server offerings and non NeXtScale components within the same cluster rack. Lenovo NeXtScale System is comprised of compute nodes and chassis. The compute node is the nx360 M5 and the chassis the n1200 Enclosure.  The chassis can house up to 12 half-wide nx360 M4 and nx360 M5 nodes. The Lenovo n1200 enclosure is a light chassis without integrated networking or switching. As a result, no chassis-level management is required.  The nodes in the chassis with front access cabling would connect to top-of-rack switches installed in the same rack. Lenovo NeXtScale System is the data center solution for clients who are facing challenges such as physical space, budget, and low productivity due to late production readiness. Lenovo delivers NeXtScale, a dense platform that not only is cost optimized but also provides tremendous time to value by helping clients get on-board more quickly.

    Thanks for the suggestion.
    One concern I have is this package is developed for v12.0. According to SAP, these action blocks will work in 12.1 but not in 12.2. I've tried to install it on 12.2. The configuration dialog are not working properly.
    Have anybody succefully implemented this package on 12.2?
    Best regards,
    Arnold
    Edited by: Brad Arnold on Mar 2, 2012 11:53 PM
    Edited by: Brad Arnold on Mar 2, 2012 11:55 PM

  • Standalone application for data acquisition using NI DAQ card

    I have made a standalone application in labview GUI for data acquisition and signal processing. if i have to run this application in any other computer what all softwares should be installed other than labview runtime engine...NI DEVICE DRIVER CD alone is to be installed or do i have to install any other software for data acquisition using NI daq card??
      thanks and regards
    Solved!
    Go to Solution.

    You should only need the run time engine, The device drivers for the device, maybe need VISA drivers if you are doing serial or something of that nature, You may need the channels or tasks created in NI measurements and automation if you created them there.
    There may be other things that you will need depending on what you include in your code and what tool kits that you have installed.
    Tim
    Johnson Controls
    Holland Michigan

  • Multiple Sound Card for data acquisition gives read buffer error

    I am using 6 usb based sound cards for voltages and currents mearuments of a three phase delta system.. Hardware is working well. but in labview when i use builtin Input=>sound box for data acquisition it also works well upto 4 inputs... but when i use more i.e. 6 it starts giving error "cannt perform action, read buffer is full" some thing like this... som times it goes to "not responding"...i have tried to find the solution and found in another post of this fourm to varry the sampling rate... i did it upto 96000 that is maximum ... but still problem is same...i need to know, how to manually increase the read buffer. if not possible then.. is there any way that labview stop giving any type of error during simulation?

    thnx i hv solved that problem ... now there is another problem... i am getting all my signals in computer but problem comes when i use phase detector. it keep on showing different values in phase measurement block.. how can i manage the signal with correct phase. i cannt send code cz it has many VIs and they are spread in computer. so i am pasting come photos that are showing different. look in picture...it is from same signal and the phase is different..
    Attachments:
    Capturexcvxccxvxcvcxvvxcvxcv.JPG ‏11 KB
    Capturexcvxcvxcvxcv.JPG ‏11 KB

  • Data Acquisition for Position Transducer

    I just purchased an Analog Position Transducer from SpaceAge Control, and was wondering if anyone had any code to gather the data. I must admit i'm lost when it comes to this, I thought the transducer would come like an instron where you just plug it into the computer. I have a six pronged plug that exits the device. I have a couple TI data acquisition boards at my disposal. I am hoping someone has used a similar product or has some advice. Thank You
    Keith

    We have lots of code to gather data in all sorts of ways. Building measurement applications is what we do. Since you are lost when it comes to this, you would do well to hire a guide in the form of an Alliance Member company. We do this stuff every day.
    Your TI DAQ boards may do the trick, but you would have to show someone the specs for them. Also, you need to think about what kind of speed you require and where you want the position data to go. Table? Plot? Database? A good LabVIEW developer can set you up with some code that does exactly what you want.
    Daniel L. Press
    PrimeTest Corp.
    www.primetest.com

  • Choice of design pattern for data acquisition system

    Hello all
    I have a trouble about selecting the suitable design pattern / architecture for a data acquisition system. 
    Here is the details of the desired system:
    There is data acquisition hardware and I need to use it by observing parameters on User interface. 
    the data acquisiton period, channel list to scan should be chosen on User interface. Besides, there are many user interface interactions. e.g. if user selects a channel to add scanlist, then I need to enable and make visible some other parts on user interface. 
    When user completes the channel selection, then he will press the button to start data acquisition. Then I also need to show the scanned values on a graph in real time and log them in txt file.
    I know that I cannot use producer consumer pattern here. because the data acquisition loop should wait for parameters to scan channels. and it works in a given period by user. so the user interface loop performs higher rate then consumer loop (data acquisition loop). it means queue will be bigger bigger. if I use notifier it will loss some data come from user interface. 
    is there any idea about that ? is there any suitable design pattern for this case ? 
    Thanks in advance
    best regards 
    Veli BAYAR
    Embedded Systems Software and Hardware Engineer 
    "You live in a graphical world. Why not program in one?"
    Solved!
    Go to Solution.

    johnsold wrote:
    Veli,
    I recommend the Producer/Consumer model with some modifications.
    You might need three loops.  I cannot tell for sure from your brief description.
    The User Interface loop responds to the user inputs for configuration and start/stop of acquisition.  The parameters and commands are passed to the Data Acquisition loop via a queue. In this loop is a state machine which has Idle, Configuration, Acquisition, and Shutdown states (and perhaps others). The data is sent to the Processing loop via a different queue. The Processing loop performs any data processing, displays the data to the user, and saves it to file. A notifier can be used to send the Stop or shutdown command from the User Interface loop to the other loops.  If the amount of processing is minimal and the file write times are not too long, the Processing loop functions might be able to occur in the Timeout case of the UI loop Event structure.  This simplifies things somewhat but is not as flexible when changes need to be made.
    I am not sure that a Design Pattern for this exact setup exists but it is basically a combination of the Producer/Consumer (Events) and Producer/Consumer (Data) Design Patterns.
    Lynn
    Check out this thread: http://forums.ni.com/t5/LabVIEW/Multiple-poll-case-structures-to-event-help/td-p/2551309
    There are discussions there about a 3-loop architecture that may help you.
    Jeff
    Jeffrey Zola

  • VI for measuring FRF having data writing problem

    Respected Sir/Mam,
                                        I have created a Vi for measuring the signal during modal analysis. The Vi is giving a very good signal but the problem is in writing the data. The no of samples is given as 10K and rate is 100k but it writes only 5k datas in the file. The signals are good but the data logging is the problem. I have attached the VI. Your earliest reply will be very much helpfull to carry out my further work.
    thanking you
    ram
    Solved!
    Go to Solution.
    Attachments:
    RAM.vi ‏141 KB

     I first of all thank you for your valuable reply in the labview forum.                        I posted a question sayiny the " VI for measuring FRF ( Freqency Response Function ) having data writing problem"  Sir actually the data i am storing is to be further used for plotting the mode shapes.
                                1. When i plot the data i am not getting back the orginal plot that i acquired during my experiment.
                                2. No of samples to read i have mentioned is 10K. But the VI reads only 5K data.
                                3. The rate is given as 100K
                          Sir i have attached the image of plot which i got from the experiment.The experimental plot is good the problem is qwith the data being saved it in not completly storing the data.
                           The problem is VI is storing only 5K data from 10K it is missing 5K of data while writing to file. I am attaching the VI and plot.
    Attachments:
    RAM.vi ‏141 KB
    FRF PLOT.JPG ‏279 KB

Maybe you are looking for