Data transmition using serial com

Hello everyone,
I'm new to JAVAME, and would like to ask how can I send numeric value 1-3 to the pc serial com port, I'll be using the hyperterminal to see the value recieved. The phone I'm using is Nokia N95..any link or ideas will be appreciated.
Thanks in advance,
joseph

LuI wrote:
>
> Hi all,
>
> I am frustrated on VISA serial comm. It looks so neat and its
> fantastic what it supposes to do for a develloper, but sometimes one
> runs into trouble very deep.
> I have an app where I have to read large amounts of data streamed by
> 13 µCs at 230kBaud. (They do not necessarily need to stream all at the
> same time.)
> I use either a Moxa multiport adapter C320 with 16 serial ports or -
> for test purposes - a Keyspan serial-2-USB adapter with 4 serial
> ports.
Does it work better if you use the serial port(s) on your motherboard?
If so, then get a better serial adapter. If not, look more closely at
VISA.
Some programs have some issues on serial adapters but run fine on a
regular serial port. We've had that problem recent
ly.
Best, Mark

Similar Messages

  • I pull fiftyfour bytes of data from MicroProcessor's EEPROM using serial port. It works fine. I then send a request for 512 bytes and my "read" goes into loop condition, no bytes are delivered and system is lost

    I pull fiftyfour bytes of data from MicroProcessor's EEPROM using serial port. It works fine. I then send a request for 512 bytes and my "read" goes into loop condition, no bytes are delivered and system is lost

    Hello,
    You mention that you send a string to the microprocessor that tells it how many bytes to send. Instead of requesting 512 bytes, try reading 10 times and only requesting about 50 bytes at a time.
    If that doesn�t help, try directly communicating with your microprocessor through HyperTerminal. If you are not on a Windows system, please let me know. Also, if you are using an NI serial board instead of your computer�s serial port, let me know.
    In Windows XP, go to Start, Programs, Accessories, Communications, and select HyperTerminal.
    Enter a name for the connection and click OK.
    In the next pop-up dialog, choose the COM port you are using to communicate with your device and click OK.
    In the final pop
    -up dialog, set the communication settings for communicating with your device.
    Type the same commands you sent through LabVIEW and observe if you can receive the first 54 bytes you mention. Also observe if data is returned from your 512 byte request or if HyperTerminal just waits.
    If you do not receive the 512 byte request through HyperTerminal, your microprocessor is unable to communicate with your computer at a low level. LabVIEW uses the same Windows DLLs as HyperTerminal for serial communication. Double check the instrument user manual for any additional information that may be necessary to communicate.
    Please let me know the results from the above test in HyperTerminal. We can then proceed from there.
    Grant M.
    National Instruments

  • Capturing data acquisition frames reliably at 100 hz using serial, how?

    Hi All,
    I am completing development of a 14 channel, 10 bit resolution, pic based data acquisition circuit. It transmits frames of 41 bytes (currently) at 100hz using serial. The embedded code functions satisfactorily. I can see data ok using hyperterminal. I am unsure how to optimise labview to get complete frames without hogging lots of cpu/system resource etc. eg. do I simply set the frame size (num of bytes) to retrieve and set this looping as fast as possible , and/or set the rate to fetch frames at the rate frames are transmitted by the pic? This may allow drift in available buffered bytes to finally overflow the buffer.
    I tend to lose 1 byte in 100 typically doing nothing but this increase
    s to chunks of bytes if I interact with windows.
    I have the feeling a number of decisions need making when setting up a serial link like this but I am unsure which settings best suit my application.
    Thanks in advance,
    Regards
    Chris

    Hi Lynn, Tristan,
    Please find the current llb attached. This has my last serial run and shows how the data gets glitchy after a number of seconds (toward end of the text box).
    I have spent time building the suggestions into code. I am not yet trying to strip out individual channels. At the moment I just want to get frames in reliably before moving on.
    It certainly looks a lot more reliable now but a few more questions have been raised. I think the idea of getting data in using 1 loop then immediately passing it for processing by another parrallel loop seems important for reliability.
    You will notice I grab a frame and it then goes into a que where it will be processed but this needs doing quickly as frames will be used in realti
    me.
    I have set up the code to trim the delay for both the get data from serial port loop and get 1 entry from the que loop.
    I am using 2 identical circuits in my product, 1 captures data from a leg harness, the other controls movements of a biped robot (servos) this occurs in "real time". I need to remove as much latency due to processing as possible.
    click on "video 3" on the right of the page for a prototype demo:
    http://www.robotic-systems.co.uk/products/full_system.htm
    I noticed that some of text embedded within text boxes used in subvi's can tend to float thro to the top level vi. I proved this by adding a bit of text and noticed it kept cropping up occasionally on the top level text box. I found this peculiar but cured it by deleting all chars in the subvi text box. Now I am concerned, could this be somthing to do with why I get glitches in text occasionally?
    Is there some labview feature to say flush all text, numbers and bools prior to running from the top leve
    l?
    I'd be gratefull if you have a look thro my llb and sanity check the flow of code and let me know what you think.
    Best Regards
    Chris
    Attachments:
    Monitor.llb ‏722 KB

  • Need to build communication redundancy using serial RS-232 for Data Transfer b/w Host and RT irrespective of TCP/IP Data Transfer

    Hi - I would like to build the logic in which it should accomodate the communication redundancy using serial RS-232 for Data Transfer b/w Host and RT irrespective of TCP/IP Data Transfer.
    I want to do data transfer b/w host and RT through RS232 VISA portal whenever TCP/IP ethernet cable has been unplugged from the controller continuosly , it should keep on checking for TCP/IP link re-establishing also , when ever the tcp/ip link established again that time the communication should be using in that link only. This is accomplished by deploying the RT vi as execuatbale file. I made some logic regards to the above said logic , bur it was not working as much I expected.
    I request you to go through the attached two VI's and let me know , what I did wrong in that,
    Please do the needful.
    Attachments:
    TCP_Serial_Host.vi ‏33 KB
    TCP_Serial_RT.vi ‏41 KB

    even i am new to this topic and i am trying to get familiar with these protocols
    refer to tcp server/client examples in labview examples

  • I want to transfer data through the serial port in the same coding that hyperterminal uses. How can i do it?

    The serial port seems to be working, and labview seems to be sending the data, but the problem is in which format does it send the data, because in hyperterminal i just input the string "JDX" and it sends it to my device, with labview it sends something but my device does not recognize it.

    nobuto wrote:
    > I want to transfer data through the serial port in the same coding
    > that hyperterminal uses. How can i do it?
    >
    > The serial port seems to be working, and labview seems to be sending
    > the data, but the problem is in which format does it send the data,
    > because in hyperterminal i just input the string "JDX" and it sends it
    > to my device, with labview it sends something but my device does not
    > recognize it.
    Hyperterminal adds the carriage return/line feed to the string which is
    generated by the return key to send out the current line. LabVIEW simply
    sends out what you tell it, so try to set the string to "Show \ Display"
    format and add a \r or \n or \r\n to the command you want to send out.
    Assumes of course that you set the right baudr
    ate/bits/parity etc in
    LabVIEW with the VISA property node, when opening the serial port.
    Rolf Kalbermatter
    Rolf Kalbermatter
    CIT Engineering Netherlands
    a division of Test & Measurement Solutions

  • My users folder has 140GB used on it, but I cannot find where it is getting that calculation. I went through all of my folders and opened them all in an info panel, and they all come out to about 30GBs. Where is the rest of the data? -Using Mountain Lion

    My users folder has 140GB used on it, but I cannot find where it is getting that calculation. I went through all of my folders and opened them all in an info panel, and they all come out to about 30GBs. Where is the rest of the data? -Using Mountain Lion

    First, empty the Trash if you haven't already done so.
    Use a tool such as OmniDiskSweeper (ODS) to explore your volume and find out what's taking up the space. You can delete files with it, but don't do that unless you're sure that you know what you're deleting and that all data is safely backed up. That means you have multiple backups, not just one.
    Proceed further only if the problem hasn't been solved.
    ODS can't see the whole filesystem when you run it just by double-clicking; it only sees files that you have permission to read. To see everything, you have to run it as root.
    Back up all data now.
    Install ODS in the Applications folder as usual.
    Launch the Terminal application in any of the following ways:
    ☞ Enter the first few letters of its name into a Spotlight search. Select it in the results (it should be at the top.)
    ☞ In the Finder, select Go ▹ Utilities from the menu bar, or press the key combination shift-command-U. The application is in the folder that opens.
    ☞ Open LaunchPad. Click Utilities, then Terminal in the icon grid.
    Triple-click the line of text below to select it, then drag or copy — do not type — into the Terminal window:
    sudo /Applications/OmniDiskSweeper.app/Contents/MacOS/OmniDiskSweeper
    Press return. You'll be prompted for your login password, which won't be displayed when you type it. You may get a one-time warning not to screw up.
    I don't recommend that you make a habit of doing this. Don't delete anything while running ODS as root. If something needs to be deleted, make sure you know what it is and how it got there, and then delete it by other, safer, means.
    When you're done with ODS, quit it and also quit Terminal.

  • I always lose data when i read continous using serial

    I am developping a application, using serial communication for data
    acquisition.
    This serial read data continuous.but when i click on the graph or made
    a zoom i lose data in that interval ...
    What can i do

    If I understand correctly what you're saying, there is a gap in you data when you click on the graph, or zoom in on it. If you have the acquisition and the graph in the same loop, you could be essentially pausing or slowing down the loop while you are interacting with the graph. I've never noticed this effect before myself, but it is possible.One solution might be to put the acquisition process in a seperate loop and pass data to the loop containing the graph in something like a queue.Mike...
    Certified Professional Instructor
    Certified LabVIEW Architect
    LabVIEW Champion
    "... after all, He's not a tame lion..."
    Be thinking ahead and mark your dance card for NI Week 2015 now: TS 6139 - Object Oriented First Steps

  • Using DLL in LV for a serial com

    Hi,
    I'm trying to implement in LV a software involving a pan-tilt-zoom motor control, which works with a pretty large communication protocol but have C++ written DLL.
    I have tested the DLL with a c++ program, and it works fine, but when I try to use it in LV it doesn't work at all!
    To start with, i'm trying to run a basic program, with 2 vis from the dll:
    The first VI (Init.vi) Configures the serial com port receiving the name (for example COM4) and the baudrate (9600) and returns the handler for the port
    The second (TiltUp.vi) vi receives the handle, and sends the packet through the port
    The problem is that the first Init.vi doesn't seem to initialize the port. I'm using C calling convention for every vi, and running them in the UI thread.
    Do you have any idea of what could be my problem? It is possible to configure and get the port handler any other way in LV?
    Thank you very much!
    Attachments:
    lv-ptz.JPG ‏41 KB
    library-call-conf.JPG ‏50 KB

    nyc escribió:
    LabVIEW has built-in serial port functions.
    I'd start with those before trying to use a DLL.
    I know, but i was trying to use the c++ library to avoid the entire protocol coding in LV...
    I will modify the library to avoid the entire implementation of the protocol.. but using the VISA Serial lib
    Thank you nyc! 

  • I'm new to the LabView. How do I pass data from VI configured using Serial (CMTS using CLI commands to set Parameters ) to VI configured using GPIB(vecto​r signal analyzer ) to measure such as RF frequency or power on the instrument​? Thanks

    I'm new to the LabView. How do I pass data from VI configured using Serial (CMTS using CLI commands to set Parameters ) to VI configured using GPIB(vector signal analyzer ) to measure such as RF frequency or power on the instrument?
    I just want to set something on the front panel that will execute the Serial parameters first and then pass these settings to vector signal analyzer
    Thanks
    Phong

    You transfer data with wires.
    Frankly, I'm a little confused by your question. I can't think of any reason why you would want to pass serial parameters (i.e. baud rate, parity) to a GPIB instrument. Please explain with further detail and attach the code.

  • Problem in using serial port.

    I am using serial port to get data from a fusion splicer. The number of bytes at the port is 4096 but the read buffer of VISA read is empty. I am reading the same number of bytes. Can any one tell me what is the maximum size of VISA Read buffer? I am trying to put the contents of the buffer in a file. I am using labVIEW 6.1 on linux.I am also attaching the VI.
    I also noticed this problem...If I read the number of bytes in the serial buffer many times, sometimes it reads it as 0 and I have to keep trying until it reads this 4096 bytes.
    Thanx for any help.
    S.Vijayalakshmi
    Attachments:
    serail_comm.vi ‏52 KB

    Hey Viji,
    In your application it looks like you are just checking to see how many bytes are at the serial port. Is it possible that your application is check for the serial data at the port before the data actually gets there. If you are looping this code as a subVI or just running it over and over it is possible that one of the iterations could occur faster than your device can write the information to the bus. In this instance you are checking the number of bytes at the port and there might not be any there yet. In this case the port reads 0 as you have designed it.
    If you want the read function to wait and always read 4096 then don't wire the bytes at port to the read function. Just wire a constant/control equal to 4096 to the read function instead o
    f the bytes at port. In this case, if there are not any bytes at the port the read function will wait for the bytes to show up or until the timeout period is reached.
    I would also, suggest lowering your time to something more reasonable, because if your instrument quits transmitting your application is going to wait for 33 minutes. That is a long time for a program to hang.
    I hope this helps out.
    JoshuaP
    National Instruments

  • [svn:osmf:] 13042: Fix for FM-287, reinstating the main sample ( that uses serial and parallel composition), and making another pass at  getting all the changed trait methods mapped correctly back- and forth between JS and Flash .

    Revision: 13042
    Revision: 13042
    Author:   [email protected]
    Date:     2009-12-17 03:45:27 -0800 (Thu, 17 Dec 2009)
    Log Message:
    Fix for FM-287, reinstating the main sample (that uses serial and parallel composition), and making another pass at  getting all the changed trait methods mapped correctly back- and forth between JS and Flash.
    Ticket Links:
        http://bugs.adobe.com/jira/browse/FM-287
    Modified Paths:
        osmf/trunk/apps/samples/framework/HTMLGatewaySample/HTMLGatewaySample.as
        osmf/trunk/apps/samples/framework/HTMLGatewaySample/html-template/index.template.html
        osmf/trunk/framework/MediaFramework/org/osmf/external/HTMLElement.as
        osmf/trunk/framework/MediaFramework/org/osmf/gateways/HTMLGateway.as

    Perre wrote:I'm used to being able to pick one or a couple of songs and then adding it a specified playlist. Is this impossible in sonata?
    It's clearly not impossible, just different than you expect. Create your playlist as you want it to appear in the Current tab (meaning don't dump every single song from your library in there, just the ones you want) and then save the playlist.
    Perre wrote:And if I try to play the m3u file created (the one with every song listed) through freevo I get a message that the directory is empty. What am I doing wrong??
    Look at save_absolute_paths_in_playlists in your mpd.conf.

  • HTML DB and Serial(COM) Port

    Hi, everyone,
    Is there any way that HTML DB can communicate with Serial Port (COM Port) directly? I searched the forum, and saw someone mentioned "Visual Baisc", "Javascript", "ActiveX", or "DLL". Could anyone give an example for it if you had successful experiences about it?
    My problem is I'm working on a HTML DB project which will read data from barcode scanner. And request I have is the HTML DB can monintor the Serial Port and read the data from there if there is one. That means some programs need to be embedded in or called in HTML DB page. I known there are some commerial software developed for this purpose on the market, but I am wondering if it can be done by HTML DB itself?
    Thank you. And Regards,
    Ran

    > Is there any way that HTML DB can communicate with Serial Port (COM Port)
    directly?
    There seems to be a misunderstanding or lack of understanding about what APEX/HTMLDB is ito client-server architecture.
    APEX is a server side application. It resides entirely in Oracle as PL/SQL software. It is executed by Oracle server processes that are servicing requests from a web (i.e. Apache) server.
    APEX does not "run" on the client. APEX streams, via the web server, data to the client browser. These MIME streams can be anything from HTML, XML, plain text (like CSV data), to images and so on.
    The browser receives this data stream, and depending on the browser configuration, does something with it - e.g. it renders a HTML data stream, it starts Flash Player plugin for a Flash graph, etc.
    The browser interacts with the client. With the user, the mouse, the keyboard, the printer and any other peripherals the client may have - like a barcode scanner.
    Can HTMDBL use a COM port? The more correct question is, Can PL/SQL in the Oracle Server Process access the COM port of the Oracle Server Platform?. The answer to that is yes - it can be done.
    But in the context of client interaction and the COM port being that of the client platform - no. PL/SQL is a server-side language. It does not execute on the client in the client browser.
    It is important to understand the web client-server architecture - as it is a lot more complex and inflexible and slower than the "traditional" client-server architecture. It is stateless. It uses a very "primitive" client, the web browser. It is bound to W3C standards which is the lowest common denominator. Forget about smooth and slick client GUIs using and supporting the latest desktop GUIs standards and controls. Forget about easily interfacing with the client platform's file system and peripherals and so on.

  • Reading data from a serialized file(Data is in special characters &symbols)

    Please help me.... I struck up at reading data in a serialized file. It is a text file with some special characters. My question is - Is it a real serialized file or some bad file? If it a real good one please tell me which method i have to use to read? Actually i have to read records with time stamps from this file and have to do some calculations on them.
    FILE CONTENTS :
    ¬í sr java.util.ArrayListxÒ^TM^Ça I sizexp w sr *com.progress.recruitment.test.email.Record¨ƒù~‹6 I aI bI cI dI idI timexp                  sq ~                      ¥¤sq ~            
    Ûsq ~ gÒsq ~ 5ásq ~ E.x

    It looks like it might contain serialized Java objects, since it contains Java class names. Have you tried reading it as such to see what happens?
    Or are you asking how to do that? In which case why not just start with the code in the Java serialization tutorial and go from there?
    Or did you not know there was such a tutorial? Google keywords: "java serialization tutorial".

  • Issue in Data transfers using ALE for E-Recruiting standalone system

    Dear Experts,
    We have an issue in data transfers using ALE. We are having standalone system where E-Recruiting is maintaind seperately and the version is EHP5.
    When we configured iDoc in Sandbox and its working fine. But when it comes to Dev and Quality servers this is not working fine.
    we have created iDocs using the following filters.
    For Object P: Infotypes 0000, 0001, 0002, 0003, 0006, 0024, 0105.
    For Objects O,S: 1032, Subtype: 0010
    For Object: 1001, Subtype: A003, A008, A012, B007
    For Object O: 1001, Subtype: A002, B002, B003, B012, Tyoe of related object: O,S
    For Objects: C, O, S, Subtype: 1000, 1002, 1028
    For Object:C, Subtype: 1001, Subtype: A007
    When we do the data transfers in Sandbox using PFAL it is transferring the data properly.
    But when we do the same iin Dev and Quality servers we are not able to do it and gettign 52, 51 errors.
    Here we are facing a strange issue. For some Users when we transfer data it is transferring data but with 52 error messgae.
    For some users I am getting 51 error where i could not transfer any data.
    For some users, when we tranfer O, S, and P related data is moving but getting mostly 52 error and all the relationships are not moving here for O,S and properly. But P related CP, BP and NA are getting created successfully.
    It is happening only in Dev and Quality server and that too some users are able to get transferred but not all.
    Where will be the issue? How can we resolve this?
    Any help will be appreciable.
    Thank you in advance.

    Hi Sekhar,
    Have a look over these threads.
    Errors in ALE data transfer to E-Recruiting.
    http://scn.sap.com/thread/1535402    
    BR,
    RAM.

  • Extracting SQL statement from a Webi document's data provider using SDK.

    Hi all,
    Is it possible to extract the SQL statement from an existing Webi document's data provider using BO SDK?  I've searched through the class library but haven't found any information on this yet.  If you have done it, could you provide some guidance.  Many thanks.

    I found the following Java code that might be of some help to you. I realize you are using .NET but this might push you down the right path.
    The trick here is to use the Report Engine SDK to get the DataProvider of the DocumentInstance. Then, look at the SQLDataProvider to get your SQLContainer.
    My apologies for the poor formatting. This didn't copy and paste over to the forums very well. I've cleaned up as much as I could.
    <%@ page import="com.crystaldecisions.sdk.framework.*" %>
    <%@ page import="com.crystaldecisions.sdk.exception.SDKException" %>
    <%@ page import="com.crystaldecisions.sdk.occa.infostore.*" %>
    <%@ page import="com.businessobjects.rebean.wi.*" %>
    <%
    boolean loginSuccessful = false;
    IEnterpriseSession oEnterpriseSession = null;
    String username = "username";
    String password = "password";
    String cmsname  = "cms_name";
    String authenticationType = "secEnterprise";
    try
    //Log in. oEnterpriseSession = CrystalEnterprise.getSessionMgr().logon( username, password, cmsname, authenticationType);
    if (oEnterpriseSession == null)
    out.print("<FONT COLOR=RED><B>Unable to login.</B></FONT>");
    else
    {  loginSuccessful = true;
    catch (SDKException sdkEx)
    { out.print("<FONT COLOR=RED><B>ERROR ENCOUNTERED</B><BR>" + sdkEx + "</FONT>");}
    if (loginSuccessful) { IInfoObject oInfoObject = null;
    String docname = "WebI document name";
    //Grab the InfoStore from the httpsession IInfoStore oInfoStore = (IInfoStore) oEnterpriseSession.getService("", "InfoStore");  //Query for the report object in the CMS.  See the Developer Reference guide for more information the query language.   String query = "SELECT TOP 1 * " +        "FROM CI_INFOOBJECTS " +        "WHERE SI_INSTANCE = 0 And SI_Kind = 'Webi' " +        "AND SI_NAME='" + docname + "'";
    IInfoObjects oInfoObjects = (IInfoObjects) oInfoStore.query(query);
    if (oInfoObjects.size() > 0)
    //Retrieve the latest instance of the report  oInfoObject = (IInfoObject) oInfoObjects.get(0);
      // Initialize the Report Engine  ReportEngines oReportEngines = (ReportEngines)
    oEnterpriseSession.getService("ReportEngines"); 
    ReportEngine oReportEngine = (ReportEngine) oReportEngines.getService(ReportEngines.ReportEngineType.WI_REPORT_ENGINE);
      // Openning the document  DocumentInstance oDocumentInstance = oReportEngine.openDocument(oInfoObject.getID());   
    DataProvider oDataProvider = null; 
    SQLDataProvider oSQLDataProvider = null; 
    SQLContainer oSQLContainer_root = null; 
    SQLNode oSQLNode = null;
    SQLSelectStatement oSQLSelectStatement = null; 
    String sqlStatement = null;
      out.print("<TABLE BORDER=1>");
    for (int i=0; i<oDocumentInstance.getDataProviders().getCount(); i++)
    oDataProvider = oDocumentInstance.getDataProviders().getItem(i);
      out.print("<TR><TD COLSPAN=2 BGCOLOR=KHAKI>Data Provider Name: " + oDataProvider.getName() + "</TD></TR>");
       if (oDataProvider instanceof SQLDataProvider)
    oSQLDataProvider = (SQLDataProvider) oDataProvider;
        oSQLContainer_root = oSQLDataProvider.getSQLContainer();
        if (oSQLContainer_root != null)
    for (int j=0; j<oSQLContainer_root.getChildCount(); j++)
    oSQLNode = (SQLNode) oSQLContainer_root.getChildAt(j);
          oSQLSelectStatement = (SQLSelectStatement) oSQLNode;             
    sqlStatement = oSQLSelectStatement.getSQL();     
    out.print("<TR><TD>" + (j+1) + "</TD><TD>" + sqlStatement + "</TD></TR>");   
    else
    out.print("<TR><TD COLSPAN=2>Data Provider is not a SQLDataProvider.  SQL Statement can not be retrieved.</TD></TR>");   }  }  out.print("</TABLE>");
      oDocumentInstance.closeDocument(); }
    oEnterpriseSession.logoff();}%>

Maybe you are looking for

  • My computer isn't recognising my new ipod nano.  And it doesn't show up in my itunes account.  Any suggestions?

    Am trying to sync ipod nano 7th generation with i tunes but ipod isn't showing up on PC - nor in i tunes.  My computer doesn't recognise that my ipod is connected to it. Any ideas?   I thought I simply needed to follow the online instructions on itun

  • Remote access to WebDB

    I can connect to my WebDB host (RedHat 6.1, Oracle 8.1.5 and WebDB 2.2) only from my localhost. If I try to connect from a remote machine, my web browser tells me that may server is busy or down. Why? Thanks

  • MAX 7041/6040 export

    Hello, I got 2 PC with PCI 7041/6040E RT Target. I'd like to export tasks and channels of the 6040 with max from one PC and import it to the other. But when i chose RT::1 (which is my 7041 RT device) in the export wizard, it doesn't show me channels

  • "reconnect" old events to the Event Library

    I imported a bunch of DV tapes last spring(onto HDD "iMovie VIdeos 1") and everything worked great, but I hadn't used iMovie since then, until this week. I'm now importing old VHS tapes(onto HDD "iMovie VIdeos 2"). This importing is also going well.

  • Compatibility of jinitiator

    Hi, i m facing a problem with jinitiator. i have to use jinitiator 1.1.8.21 for oracle apps 11.5.10 and i need jinitiator 1.1.8.16 for oracle apps 11.5.9. i need to access both the servers and only one copy of jinitiator can be there. so is there any