Default value of a numeric control

Hello I want to fix the default value of a numeric control using his node property but I haven't found this attribute. It's possible to fix this value through the node property of a block?
I've tried to fix it, right-clicking on the control....properties....default value....but when I save the vi's and I reopen the vi's, his value has disappeared and value is set 0.
Do you know another way to fix this value?
Thank you in advance
Larson

The default value is only relevant when the VI is loaded into memory, not every time you start running it. Your code is probably changing the value to some out-of-limit value (probably 0 if your calculations are incorrect) and it is coerced to the minimum. If you want a value to remain constant, don't change it.
The answer is simple - DON'T RUN CONTINUOUSLY! If you want something to repeat, use a loop. That way, the value will only need to be read once, when the VI starts running. If this didn't help you, you should post the VI and explain more about your problem.
To learn more about LabVIEW, I suggest you try searching this site and google for LabVIEW tutorials. Here and here are a couple you can start with. You can also contact your local NI office and join one of their courses.
In addition, I suggest you read the LabVIEW style guide and the LabVIEW user manual (Help>>Search the LabVIEW Bookshelf).
Try to take over the world!

Similar Messages

  • NaN as default value for LabVIEW numeric control

    TestStand 2010 SP1, LabVIEW 2011 SP1
    This may be a "feature" but I also may be missing something here.
    Reproduce my issue doing this:
    Create a VI with a numeric double.  Set the value to NaN.  Make that the default value.  Connect it to the connector pane.  Try and call it from TestStand.  The prototype will not reload.  Why?  NOTE: it only works for controls and not indicators.
    Not sure if it's related to this because that's in .NET: http://forums.ni.com/t5/Measurement-Studio-for-NET/NaN-as-default-value-for-a-numeric-edit-control/t...
    We have hundreds of VIs with the default set to NaN.  We started seeing this issue when we just upgraded to the latest dev suite.
    Thanks in advance,
    jigg
    CTA, CLA
    teststandhelp.com
    ~Will work for kudos and/or BBQ~

    The prototype reloads fine in TestStand 4.2.1 and LabVIEW 2010, as you probably already knew.
    In TestStand 2010, the problem is that it doesn't reload only when you set to NAN?  Or does it never reload no matter what the numeric value is?
    What is your logic for using NaN values?  Are these values that are not used in tests?  We have a suite of over 50+ tests and I have never used NaN values as inputs.
    Thanks,
    PH

  • How to get y axis value(in a numeric control) by providing x-axis value using wave graph

    Hi,
    I'm new here, Sorry if i have selected wrong Location.
    I want to get Y-axis value (in a numeric Control) by providing X-axis Value using Wave graph.
    i want to do calculations with the obtained value.
    i have attached File and Snapshot.

    Well, you are using the Dynamic Data Type, which I almost never use, but if you convert the data to a WaveForm (using From DDT on the Signal Manipulation Palette, which is a choice when you right-click on the DDT Wire), you should be able to do this.  Do you know about how Waveforms are stored?  They are a Cluster, with t0 being a TimeStamp for the start of the Waveform, dt being the time step, and Y being the samples.  So if you want a point at 0.5 seconds and dt is 0.001, you would pull out the point at Index 499 (offset 0) from the Y array.
    Bob Schor

  • How to set the current month as the default value of an input control?

    Hello,
    I want to set the current month or current year as the default value of an input control. Something like try to get the month from the currentdate() formula and assign it to the input control.
    Is this possible?
    Thanks & Regards
    SU

    >
    soauniverse wrote:
    > Hello,
    >
    > I want to set the current month or current year as the default value of an input control. Something like try to get the month from the currentdate() formula and assign it to the input control.
    >
    > Is this possible?
    >
    > Thanks & Regards
    > SU
    I don't think so.  I tried to find a property or something in that Input Control but there is nothing to set it that way.

  • How can I highlight the default data in a numeric control when a VI loads.

    I have a VI that features a string constant that asks for a numeric response via a numeric control, a "next" button that enters the data (controlled by the enter key), and two leds, one that lights if the data entered is correct, and one that lights if the data entered is incorrect.  Is there anyway that I can make sure that when this VI loads, the zero in the numeric control is highlighted?
    Currently the opeator must use the mouse to highlight the zero in the numeric control, type the number and press enter ("next") to advance in the program.  I want the operator to be able to simply type the number after the VI loads and press enter.  This would require the zero to be highlighted when the VI loads.
    Is there anyway that I can format the numeric control to do this?

    If you set the key focus of the control to true (Right click on
    control->Create->Property Node, then on the property node, select
    "Key Focus") before anything else, it should be highlighted when you
    run the program.

  • Set initial value for numerical control

    Hello LV users,
    I have a VI that is used to initialize some experimental equiptment. It passes on a cluster of ten or so numerical control DBL integers as parameters. Everytime I open the programe the values are reset back to zero and I have to enter the values back in. Is there any way to set default values for  the controls so I do not have to change them everytime I open the program.
    Thanks 
    Solved!
    Go to Solution.

    Wowden,
    If you want to set default values for multiple numeric control's in your cluster in one go, 
    -Type in the desired default values
    - Right click on your cluster, browse to 'data operations'
    - Choose 'Make current values default. 
     Similarly, if you need to set defaults for  multiple clusters or multiple controls on your front panel,
    - Choose 'Edit' in the menu 
    - Choose "make current values default' (This sets defaults for all controls/constants etc. in one go)
    RaVI

  • How can I change the numeric and enum default values in a Strict Type Def Cluster?

    I have a Strict Type Def cluster that contains 10 Numerical controls and a number of enums.  I have edited default values of the numerical controls in the Strict Type Def, in customize mode, performed a "Make Current Values Default"  and have done a "Apply Changes"  and saved.
    This cluster is used in various locations throughout the project and have not found a way to make the cluster default values change downstream.  The Strict Type Def (STD) Control appears to have the right values on the front panel.  But if I place an instance of this on a blank front panel, and run a wire from it in the block diagram with a probe and indicator, I still get the old default values being passed from the STD.  
    Solved!
    Go to Solution.

    There Are No Strict Type Definition Constants
    "Even though typedefs only update when types change, instances get cosmetic changes from the definition whenever they update. So one trick to "push" changes to typedef instances is to change the data type, apply changes, and then change the data type back. [edit, March 26 - Note that the typedef instances need to be in memory when you use this trick]."
    From Eyes on VIs, here.
    http://blog.eyesonvis.com/
    I love this article.
    Jim
    You're entirely bonkers. But I'll tell you a secret. All the best people are. ~ Alice

  • XML FORM  -  How to save read-only controls with a default value

    Hello everybody,
    I have a 3 xml forms, each one to create one type of news. I need to use 3 because each of this forms has their own controls. But the control which indicates the type of news (asociated with a KM Predefined Property) must be common in the 3 forms, in order to use it on searches.
    The question is, how can I include in this forms a control:
      - Visible for the user
      - With a default value defined in the control properties (each form has a different value, corresponding with the type of news)
      - Read-only mode
      - The value showed in the control must be saved in the associated KM Predefined Property when the user clicks the Save button. 
    Anyone knows how to do this?
    What control can I use?
    I was thinking of trying with text boxes, but I don't find the way to make them unwritable (Read only mode).
    It is posible using labels?
    Thanks.
    Kind regards

    Hello Jose,
    I know you responded with a question... I see it in the email, but I don't see it here!  Very odd... but in response:
    The first thing I do when I open the Edit.xsl file is do a 'find' for the name of the text field that I want to be read-only (in my test case, it's 'location').  Repeat the find until you see something like:
    [code]<!--
    field location
    -->[/code]
    Below there is where I put the new code.  Mine looks like this:
    [code]- <xsl:choose>
    - <xsl:when test="location='' and ($editmode='create')">
    - <xsl:choose>
    - <xsl:when test="./xf:ValidationError/@tagname='location'">
    - <input name="location" size="30" type="text" class="urEdfiTxtEnbl" id="field_1157467268006">
    - <xsl:attribute name="tabindex">
    - <xsl:choose>
      <xsl:when test="$accessibilitymode='true'">21</xsl:when>
      <xsl:otherwise>3792</xsl:otherwise>
      </xsl:choose>
      </xsl:attribute>
    - <xsl:attribute name="value">
      <xsl:value-of select="''" />
      </xsl:attribute>
    - <xsl:attribute name="readonly">true</xsl:attribute>
      </input>
      </xsl:when>
    - <xsl:otherwise>
    - <input name="location" size="30" type="text" tabindex="3792" class="urEdfTxtEnbl" id="field_1157467268006">
    - <xsl:attribute name="value">
      <xsl:value-of select="''" />
      </xsl:attribute>
    - <xsl:attribute name="readonly">true</xsl:attribute>
      </input>
      </xsl:otherwise>
      </xsl:choose>[/code]
    I put the <xsl:attribute name="readonly"> in both places (when test, and when not test).  I'm not entirely sure if that's necessary, but that worked for me.
    Hope this helps,
    Fallon

  • "File Path Control" default Value

    Hi - How do we set or change the default value for "File Path Control" (Control --> String & Path ---> File Path Control)?
    I typed the default path into the control field on the front pannel and save the VI file.  The value gone when I reopen the file.

    jimmy.chretien wrote:
    [...] difference between Not a path and Empty path... Why?
    Not a Path is a specific value for the path (<Not a Path>).
    Developers should use this to prevent situations in applications, where a user has to select a path before performing an action (e.g. saving a file). If the user skips the path selection, the application still has "Not a Path" and can prevent errors and tell the user to select the path (error handling!).
    Norbert
    CEO: What exactly is stopping us from doing this?
    Expert: Geometry
    Marketing Manager: Just ignore it.

  • Imaq image control (Delete default Value)

    I have a problem with the vision imaq image control.
    I have defined for a "imaq image control" a default image for the development.
    Now the default image is no longer need and i want to remove the default value an reset the Control to an empty image.
    How can i reset the default Value from the "imaq image control" to an empty image?
    Solved!
    Go to Solution.
    Attachments:
    imaq_image.vi ‏2726 KB

    Cardinal1664 wrote:
    I have about 20 Vi's with imaq image controls with default images!
    I don't want to too that progmaticaly!?
    Another possible way is to automate this task, something like this:
    Just obtain list of VIs where Vision Control should be resetted to default, then run snippet above in the cycle.
    Andrey.
    Attachments:
    Empty Images.vi ‏17 KB

  • Changing default values in .exe

    Hello
    I have created a test tool control program. This program controls pressure regulators and pressure transducers as well as a bunch of other stuff. I have the program written and it works great. I was able to create an exe and deploy it successfully. Now I realize that the calibration fields in my program need to be updated periodically by the end user due to stuff on the hardware end.
    The values in the calibration controls are editable, however when the program is closed and reopened the value returns to default. Is there a way to update the values in a numeric control and have that saved as the new default once the VI has been converted to an exe?  The calibrations only need to be updated every three months but I know that the computer system will be shut down at least once a week. When the program is restarted I would like the last values in those fields to be retained without having to create a new exe. Is there another option besides a read from file?
    Thanks,
    Ross
    Solved!
    Go to Solution.

    tst wrote:
    Note that it's also relatively easy to write code which won't require you do this manually for every single control. OpenG has a VI which does this for all the controls on the panel, but you can also use something like this to do this for specific controls (or for all the controls, if you get the panel's Controls[] property).
    The OpenG is handy but if a human needs to edit the file it is not the most human friendly.
    Mark Yedinak
    "Does anyone know where the love of God goes when the waves turn the minutes to hours?"
    Wreck of the Edmund Fitzgerald - Gordon Lightfoot

  • How to change default values in SCC?

    Hi,
    does anyone knows how to change the default values of the Sybase Control Center e.g.:
    Activation Code Expiration (Hours) – indicates how long an activation code is valid. The default is 72 hours.
    Within SCC the field is deactivated, it's changeable after creating a connection, but I need to set it within the connection template.
    Thanks in advance, Christian

    You're right, but we want to change the default setting of the template, to avoid this step.
    Thanks, Christian

  • A question about assigning a default value

    Hi guys, I have a question about assigning a default value to a Numeric Decision CO. This Co needs 2 parameters to compare with each other. I wanna assign para1 during runtime and para2 during design time, but I have no idea how to assign a default value to para2 during design time. Can anyone help me solve this question? Thx a lot.
    BTW I`m searching an article about Time-off example`s "details". I have read several articles about time-off example, but those are not detailed enough. I wanna know about all details of COs. Can anyone forward such article to me, plz.  Thx again.^^

    Hi,
    You can assign a default value to the parameter of a callable object.
    First attach your CO to an Action.At the action level you can assign default values to the CO Parameters.
    Select the action in the design time.
    Select the parameters tab for that action.
    Select the required paramter. At the top, you can find Default value tab, with that you can assign default value.
    I think you can achieve your requirements with Business logic CO better.
    [Business Logic CO|http://help.sap.com/saphelp_nwce10/helpdata/en/44/3d3936c5c14a8fe10000000a1553f6/content.htm]
    Thanks

  • Update while typing in numeric control?

    So...
    When I type a number into a numeric control, it doesn't update until I hit enter or click somewhere outside the control.
    Problem is, after entering the number, I want to click on a "go" button
    to do something with the new value in numeric control, but unless I
    remember to click somewhere else or hit enter first, I'm doing
    something with the old value, not the new value.
    This gets aggravating.
    How to make sure the value of the numeric control gets updated before doing something with it?
    "update while typing" exists for string controls, but seems conspicuously lacking for other types of controls...

    I cannot reproduce your described behavior: With either a local variable or the numeric control inside the event case, I never see a stale value. Please attach your VI so we can troubleshoot.
    Adding a delay to fix something like this is incorrect and dangerous. If a delay solves the problem, it points to a flaw in the code.  What if somebody will run your program on a slower computer where it would suddenly need a 12ms delay. You'd be back to sqaure one, dealing with race conditions.
    (And why are you using "mouse down" instead of "value changed"?)
    Message Edited by altenbach on 03-21-2006 05:22 PM
    LabVIEW Champion . Do more with less code and in less time .
    Attachments:
    Events.vi ‏12 KB

  • Controlling numeric slider with numeric control

    Hello,
    what i have is a numeric slider and
    a numeric control.  i would like to be able to move the slider and have
    it update the value in the numeric control and vice versa.  the problem
    is that i can update the value in the numeric control when i move the
    slider, but i can't update the slider if i try to change the value in
    the numeric control.  i was trying to use the 'value' property node for
    each of them and and wire each of the controls to the opposite property
    node.  i know they are both control but i thought if i change the
    'value' to an input then it may update.
    i have attached the vi.
    thank you
    Attachments:
    numeric_slider.vi ‏10 KB

    AdamKrzy16 wrote:
    Any help or insight would be appreciated beyond measure!
    Well, since the event structure only executes when one of the controls changes, it is blocking the loop. Dataflow in action!
    A quick solution would be to make the event structure "transparent" by adding a short and empty timeout case. Now just use a feedback node to retain the existing value if the controls did not change.
    There are probably definitely better ways to do this, but they would require more fundamental changes to your code.
    LabVIEW Champion . Do more with less code and in less time .
    Attachments:
    PID LabVIEW Program_slider try number 2MOD.vi ‏282 KB

Maybe you are looking for

  • Office 2013 deployment tool Invalid product ID error

    Hi, Im in the process of virtualizing apps like Office 2013 with App-V.  Downloading the binaries with the Office Deployment tool and converting to app-v package is very easy, I've followed this kb http://support.microsoft.com/kb/2915745 But now I wa

  • Exception Handling in Web Center for UI related Errors not working.

    Hi Guys, I have implemented Error Handling in ADF Application with Custom Model Exception Handler ( which is "CustomExceptionHandler extends DCErrorHandlerImpl") to catch all Model Layer Exception and to customize those error messages. I have impleme

  • Direct Input - Routing

    I tried to use LSMW with program RCPTRA02 to direct input routing master data, but failed. Is there any person kindly show me a example? Thank you very much.

  • How  the condition of combo box of matrix can be passed in query

    Hi, I want to get the parameter code and description for a particular category. Category code is in the matrix combo box  if i pass tat field in a where condition i cant retrieve the parameter code but its working in the database. Please identify the

  • Will there be a Firefox for iOS8?

    considering the changes that are coming to iOS8