EEWB enhancement screen null after CR transport.
Hi guys,
We did some EEWB enhancement to Opportunity and a new screen "Customer Fields" was generated and shown in GUI. But NOW, after we transported all CRs to QAS, the "Customer Fields" tab is null. No fields there. The fields exists in the structure and the screen is there too.
Do you have an idea for this?
Thanks a lot.
This issue is fixed by activate the screen manually.
Similar Messages
-
Problem with transporting the enhancement screen.
Hi,
I have transported an enhancement project. The enhancement screen doesnt show up,instead it goes for a dump. How can i resolve this.
Regards,
Sathish.yeah u can change the package.
check SE80 or se03 here u can change.
<b>[code]IN SE80--->select PACKAGE option in the first LIST BOX
and in the second list box give ur Local PACKAGE like $TMP, then u will get list of OBJECTS in that LOCAL PACKAGE.
2.Select object which PACKAGE u want to change.
3.Right click on that Object ,there u will get option like CHANGE PACKAGE.[/code]</b>
[code]Do one thing, GOTO -->SE51 with program name and Screen --->GOTO(menu item) ->Object Dic.Entry> here u can assign new PACKAGE.[/code]
Regards
Prabhu -
EEWB enhancement -Zfields not visible in Customer Fields in CRM online
Hi there,
I've run an EEWB enhancement to add some new fields to Service Process - it seemed to work correctly
and the fields have been correctly added to BTADMIN_H.
I was also able to add them to WebUI screens (as was the requirement) and they function correctly.
I then noticed that the fields are not available to view/edit in "Customer Fields" TAB in SAP online (CRMD_ORDER
transaction), when I create a new service process(complaint).
when I went to regenerate the EEWB, I noticed that many report/screen/table entries that normally appear on the log of data generated by the EEWB were missing (in comparison to previous EEWBs). I redid it a few times, but with no success.
Any suggestions, please, on how to solve this?
Thanks,
David.Hi,
That is because in EEWB you might have used some other object other than COMPLAINTS.
If you want your field to come in GUI as well then may be you need to delete this EEWB extension and create a new one.
Also check other Business Transaction like activity opportunity may be the that new field is coming in those transactions if you have choosen Bus. object as BUSINESS_ACTIVITY or BUSINESS_TRANSACTION in EEWB.
Regards,
Shobhit -
User presses F4 on the selection screen for the field ''Transport Request"
Dear ALL,
I want to build up a functionality in my report where if the user presses F4 on the selection screen for the field ''Transport Request", then it will display all the Transport Requests involving that particular User...
What I mean is the normal process that is provided by SAP on saving an object in a package & assigning it to TR...
How do we Achieve it ?Hi.
First we need to give the client after that client number related requestes display in second parameter F4 help for that purpose i used two function modules.First for read the client no dynamically after that pass the client number second function module.
then u can get all the request for that client.
DFIELD-FIELDNAME = 'P_MANDT'.
APPEND DFIELD.
CALL FUNCTION 'DYNP_VALUES_READ'
EXPORTING
dyname = 'Y9EZ_TR_COPYCLIENT'
dynumb = SY-DYNNR
tables
dynpfields = DFIELD
READ TABLE DFIELD INDEX 1 ."WITH KEY DFIELD-FIELDVALUE = 'P_MANDT'.
V_MANDT = DFIELD-FIELDVALUE.
CALL FUNCTION 'TR_F4_REQUESTS'
EXPORTING
IV_USERNAME = SY-UNAME
IV_TRKORR_PATTERN =
IV_TRFUNCTIONS =
IV_TRSTATUS = 'RNDL'
IV_FROM_DATE =
IV_TO_DATE =
IV_CLIENT = V_MANDT
IV_PROJECT =
IV_TITLE =
IV_VIA_SELECTION_SCREEN = 'X'
IV_COMPLETE_REQUESTS = 'X'
IT_EXCLUDE_REQUESTS =
IMPORTING
EV_SELECTED_REQUEST = S_TRKORR-LOW.
ES_SELECTED_REQUEST =
'TR_F4_REQUESTS' This function module for request
Regards
muralii -
"Conversion of Source System names after the transport" : O
Experts:
Environment : BI 7.0 and SP 12
<b>Tranports related to transformation rules are failing with inactive status...</b>
Further investigation on this, I have noticed that in our QA system, where "Conversion of Source System names after the transport" : O screen, we have columns
Original Source System, Target Source System, 7.0, Description(I guess, since no name is found)
Everything looks fine to me with reference to actual techinical names of source/target system...
My question there is a check box on column "7.0", which is UNCHECKED. Is this correct?
My understanding is that, this check box needs to be CHECKED, since this is related " Only Valid for RSDS, TRFN and DTPA Objects ". Is this correct?
If yes, Can I check this box in QA system, save and retransport my requests. If so, what happens to standard BW objects i.e., transfer ruels, update rules etc...
OR do i need to create another entry with same source/target system and check the 7.0 box.
OR do i need to create 3 entries with same source/target system and check 7.0 box for each entry i.e., RSDS, TRFN, DTPA.
Finally, please advise the exact steps that need to be taken here...pros and cons
Your inputs will be of great help....
Thanks,
BI
Message was edited by:
B IHi,
Yes you need to check the checkbox as it is related to Data sources and transformation and DTPs. you can mark the check box if your client is modifiable, if not you need to transport the setting from DEV. Go to
SPRO > Business Intelligence>Transport Settings--> Change Source system name after transport.
you also need to maintain the Source system IDs .
Hope it helps. -
Hi All,
Does any one know the procedure to enhance Screens related to RF. I need to enhance 'Handling unit screen' within transaction /SCWM/RFUI. The path for 'Handling unit screen' is : "/SCWM/RFUI -> 03 Inbound Processes -> 01 Unloading -> 03 Unloading by Transportation Unit". Any Information regarding this would be helpful.
Thankx in advance..Hi,
First of all you have to find out which screen is it. Press CTRLSHIFTF1. There is a Modify Screen radiobutton, and it is start a wizard, which is help you modifiy the current screen.
Hint: Usually the new screen have to save to an new FG not to the SAP standard.
Best regards,
Istvan -
Satellite U400-22n and Win7 - screen hangs after 5 min
Hi, This is my first post
Ive purchased a new U400 with Vista preinstalled, last week ; 2 days ago Ive upgraded to windows 7 32bit professional when I stared Installing it windows prompted me that it requires a full installation , so I done a normal full install, windows 7 installed normally .
Now my screen hangs after 5 min and windows gos black and reboots after 3-5 min, Ive downloaded all the drivers from the Toshiba site Ive used the auto detect, and installed the drivers one by one and tested if the reboot stops , Ive reinstalled windows now 4-5 time returned my copy to the shop and got a new copy of the windows DVD, its the same,
Please has some one any advice for me. As the shop Ive perched this from will not upgrade to windows 7 for me.hi Mather,
any bluescreens visible?
win7 32bit i guess...
you have to install all the drivers for win7 provided by toshiba in the right order!
first chipset and patchfiles if available...
i think a clean install will do the job!
make sure that the hdd is error free!
you can upgrade from vista 32bit to win7 32bit
but no chance to upgrade to a win7 64bit when a vista 32bit is installed... -
My MacBook Pro will turn on and get to the login screen. After I login though it goes to a white screen.
Please read this whole message before doing anything.
This procedure is a diagnostic test. It’s unlikely to solve your problem. Don’t be disappointed when you find that nothing has changed after you complete it.
The purpose of the test is to determine whether the problem is caused by third-party software that loads automatically at startup or login, by a peripheral device, by a font conflict, or by corruption of the file system or of certain system caches.
Disconnect all wired peripherals except those needed for the test, and remove all aftermarket expansion cards, if applicable. Start up in safe mode and log in to the account with the problem. You must hold down the shift key twice: once when you turn on the computer, and again when you log in.
Note: If FileVault is enabled, or if a firmware password is set, or if the startup volume is a Fusion Drive or a software RAID, you can’t do this. Ask for further instructions.
Safe mode is much slower to start up and run than normal, with limited graphics performance, and some things won’t work at all, including sound output and Wi-Fi on certain models. The next normal startup may also be somewhat slow.
The login screen appears even if you usually login automatically. You must know your login password in order to log in. If you’ve forgotten the password, you will need to reset it before you begin.
Test while in safe mode. Same problem?
After testing, restart as usual (not in safe mode) and verify that you still have the problem. Post the results of the test. -
my mac air died, after i reinstall from dvd drive, when i boot up again, i saw a prohibit sign showing up on the screen, then get to my logon screen. After logon, it takes very long time to load any application. pls help
OK. If you believe that.
When the disk is starting to die it can be bad for a moment and then be good for a while. If there was no problem while you were checking it of course it shows up good.
I tell you those are the signs of a disk that is about to die.
Allan -
Enhance screen for standard infotype
I need to enhance screen for standard infotype. I follow docs but nothing happens.
Here is my process by steps:
1. PM01 - select infty number
2. PM01 - generating CI_PXXXX (customer include)
3. create structure for this include
4. create customer screen for this include
5. PM01 - generate objects.
Then I am redirected to SE19 - BAdI-Builder. What should I do follow?
Created screen hasn't appear in se80 (MPXXXX00).
Thank you in advance!I suggest you place your question in [ERP HCM forum|SAP ERP Human Capital Management (SAP ERP HCM);,
-
I am working on MDI application which was developed in VC++ in VS 2012. When my application is launched, it will display a Tree. Under a tree there are 254 nodes. Basically
these nodes data are read from Configuration xml file and loaded into the Tree. By double clicking on each node, first it will create object for document class ( By calling CreateNewDocument() method) after that member variables for that
document class will be initialized and then it will create the new frame window (by calling
CreateNewFrame(pDoc,NULL). New child frame window will show under Main window to the user.
User able to see the data from child frame window.
Similarly by double clicking on each node it will create another object for the same document class and new child frame window will be opened for that node. Each child frame window runs
in different data and showed under the Main window.
Existing requirement by double clicking on each node, node data shall show in separate child window and there is no requirement for all 254 child windows opened simultaneously.
But current requirement is , all 254 child windows shall open simultaneously by double clicking on each node one by one.
In debug mode I have tried double clicking on each node. I able to open up to 50 nodes. After 50th child windows are opened, I unable to access to the application
(Unable to open further node data window since application is getting hanged).
Each child window is having tree, multiple splitter window and some additional controls (static text, ...).
Same I have tried in release mode, I able to open up to 136 child windows. After that the application fail to create the new frame window in VS 2012. i.e CreateNewFrame() return
NULL after successful created 136 child frame window. Debug purpose I have added the code to retrieve last error code by calling GetLastError() method. I got the value as "0". By closing any existing child window then I able to open remaining nodes.
At any point of time I can reach maximum of 136 child frame window that can be opened under Main window. Failing to open all 254 child frame window
simultaneously, currently I fail to meet the current requirement.
current Requirement is all 254 child frame window are opened simultaneously. Please let me know what may be the reason fail to create new frame window after 136 frame window that are
opened already. In Microsoft site, mentioned that there is no limitation for creating frame window in MDI application. I have tried another sample MDI application having limited number of controls, in which I able to create "n"
number of child frame windows. why not able to create more than 136 child frame window in my actual application?
Is there any possibility by changing project settings allow me to create 254 child frame window??
Code Snippet as below:
CDiagBaseDoc * CDiagBaseMDocTemplate::OpenDiagView( ...)
CDiagBaseDoc* pDoc = NULL;
if (pDoc == NULL)
pDoc = (CDiagBaseDoc*)CreateNewDocument();
if ( pDoc )
CFrameWnd* pFrame = NULL;
if (bAlreadyOpen)
// If Child frame window already opened, then handling the code here.
else
pFrame = CreateNewFrame(pDoc, NULL);
if (pFrame == NULL)
ASSERT(FALSE);
delete pDoc; // explicit delete on error
pDoc = NULL;
ASSERT_VALID(pFrame);
if( pDoc != NULL ) //VS2012
if ( !pDoc->OnNewDocument() )
TRACE0("CDocument::OnNewDocument returned FALSE\n");
delete pDoc; // explicit delete on error
pDoc = NULL;
pFrame->DestroyWindow();
pFrame = NULL;
if (pFrame)
InitialUpdateFrame(pFrame, pDoc);
ShowWindow( pFrame->GetSafeHwnd(), SW_MAXIMIZE ); //when opening node for the 1st time, maximize it
}<o:p></o:p>Hi MuruganK,
Have you checked how much memory your application used? You could check it by Task Manager. Maybe your application reach Memory Limits for Windows.
https://msdn.microsoft.com/en-us/library/windows/desktop/aa366778%28v=vs.85%29.aspx?f=255&MSPPError=-2147217396
Is it possible that there are some memory leaks in your application? It would better if you have made a simple sample to reproduce and narrow down this issue.
Best regards,
Shu
We are trying to better understand customer views on social support experience, so your participation in this interview project would be greatly appreciated if you have time. Thanks for helping make community forums a great place.
Click
HERE to participate the survey. -
I was trying to enter a revised p/w in itunes via the tv screen. After several keystroke mistakes, i got a message "unable to sign in". How do I get passed this to get the apple tv accessible?
Maddy Girl 2May mean you are locked out of the account. Contact iTunes.
-
when i plug in my ipod touch it goes to the battery witht he bolt under it the goes to the apple logo screen and after a while it will flash white like its trying to go to the lock screen but just restarts and restarts the process and keeps doing it. What should i do? Is there any way to fix it?
See if you missed anything here:
- iOS: Not responding or does not turn on
- Also try DFU mode after try recovery mode
How to put iPod touch / iPhone into DFU mode « Karthik's scribblings
- If not successful and you can't fully turn the iOS device fully off, let the battery fully drain. After charging for an least an hour try the above again.
- Try on another computer
- If still not successful that usually indicates a hardware problem and an appointment at the Genius Bar of an Apple store is in order.
Apple Retail Store - Genius Bar -
Hello. Today, I was updating my iPod Touch 4th Generation to iOS 6. I unplugged the iPod when it was during the installation because it appeared to be frozen. Now the iPod is stuck at a light blue screen even after I reset it. How do I fix it?
You will need to do a DFU restore by holding the home and power buttons down (while the device is plugged in to your computer) until the device's screen goes black and as soon as the screen goes black, count down from 3 and release the power/sleep button, but keep holding down the home button. Then, iTunes will say the iPod needs to be restored. The restore process will take some time and even though the iPod may appear to be frozen, don't interrupt the restore.
-
There is always a blue screen appears after the Apple logo during the booting process. And then everything is back to normal. What is this thing? Is there something wrong with my screen or something?
Nah - that's just the normal boot process.
Clinton
Maybe you are looking for
-
How do you eliminate audio from AECS3 project?
Hello, Every time I import an AECS3 project into PPCS3, the AE project has an audio track even though I don't have any audio in the AE project. What do I need to setup in AECS3 to get rid of the audio track? Thanks, Simon
-
Is it possible to check the previous backups on a certain backup file for the iPhone.
Is it possible to check the previous backups on a certain backup file for the iPhone. I need to backup and restore the files which were used in the second week of January, but now I am only able to see the latest iteration of the backup. I am assumin
-
Inspection lot with inspection type 03 - Using Inspection plan
Dear friends, I want to create an inspection lot at the time of production order release (ideally - insp type 03). But I want to use inspection plan as a task list instead of routing for that lot. Is it possible? Best Regards, Avinash
-
Here's an Odd one: Microsoft Excel 2010 Workbook "randomly" Becoming Protected
Either there are gnomes in our servers, someone is lying, or some sort of glitch is causing this issue (and honestly I'm not even sure which is most likely), but here's my story: User is working on an excel workbook. This user accesses this file all
-
JMS Message resent for for long processes
Hi, Currently we using Webspher App Server 6 and WSAD 6 as our development platform. We are also using Websphere MQ as our JMS server. We have one MDB resposible for processing data extraction/migration jobs from legacy databases that can take anywhe