ERROR: OUI-10180:Invalid Operating System group name specified. em12c instl

Hi All,
I am doing a silent install of EM12C, I have downloaded the 2 zip files from e-delivery.
The installation is done as ora3010 user whose group id is ems3010. On the same machine I have installed 11.2.0.2 with the same ora user ora3010 and group ems3010 for EM repos.
Now when I try to do the silent install of EM12C with the command
<EM_DUMP>/runInstaller -silent -responseFile $CONFIG_HOME/software_only.rsp -invPtrLoc $HOME/Middleware/oraInst.loc -waitForCompletion
with the contents of "software_only.rsp" file like below
RESPONSEFILE_VERSION=2.2.1.0.0
UNIX_GROUP_NAME=ems3010
SECURITY_UPDATES_VIA_MYORACLESUPPORT=false
DECLINE_SECURITY_UPDATES=true
INSTALL_UPDATES_SELECTION="skip"
ORACLE_MIDDLEWARE_HOME_LOCATION=/slot/ems3010/oracle/Middleware
FROM_LOCATION="../oms/Disk1/stage/products.xml"
DEINSTALL_LIST={"oracle.sysman.top.oms","12.1.0.1.0"}
b_upgrade=false
EM_INSTALL_TYPE="NOSEED"
CONFIGURATION_TYPE="LATER"
TOPLEVEL_COMPONENT={"oracle.sysman.top.oms","12.1.0.1.0"}
I get this error
ERROR: OUI-10180:Invalid Operating System group name specified.
As you can see the UNIX_GROUP_NAME is set to proper group id ems3010
-bash-3.2$ id ora3010
uid=60103010(ora3010) gid=60403010(ems3010) groups=60403010(ems3010)
Please Help.

Thanks Asheoran.
However the issue was with my Ora Inventory file OraInst.loc. I had actually installed 11.2.0.2 database on the same machine and as same user, and for that db I had a different OraInst.loc file. When I give the same OraInst.loc file for the EM install too, the error goes away. It seems we just need to have one Inventory file for both installations.

Similar Messages

  • LDAP: error code 1 - Invalid query reference]; remaining name '

    I have the following function for a paged search operation.
    Data retrieved by this function is used somewhere else to modify the Ldap Directory context.
    Despite my setting for ctx and search control as "no timeout", i've been keeping thrown the exception for operations lasting more than 5 minutes(consistently) and for some short operations(sporadically):
    Paged Search failed : javax.naming.NamingException: [LDAP: error code 1 - Invalid query reference]; remaining name '<directory>'
    I am using DirX as LDAP directory.
    Is this a time-out related exception which can be fixed in the code?
    How can it be fixed?
    There's no clue all over the web about this.
    Thanks.
          * Returns the next page of the search results.
          * The returned result from this method can not exceed page size
          * set in the constructor.
          * @return
         public NamingEnumeration nextPage(){
              //1.step Set PagedResultsControl
              NamingEnumeration results = null;
              Control[] controls=null;          
              try {               
                   if( isSearchStarted==false ){
                        isSearchStarted=true;
                        if(sortingAttributes==null)
                             controls=new Control[]{ new PagedResultsControl(pageSize) };
                        else
                             controls=new Control[]{new SortControl(sortingAttributes, Control.NONCRITICAL), new PagedResultsControl(pageSize) };
                   }else {// examine the response controls
                        cookie = parseControls(ctx.getResponseControls());
                        if( cookie!=null && cookie.length!=0 ){
                             // pass the cookie back to the server for the next page
                             if(sortingAttributes==null)
                                  controls=new Control[] { new PagedResultsControl(pageSize, cookie, Control.CRITICAL) };
                             else
                                  controls=new Control[] {new SortControl(sortingAttributes, Control.NONCRITICAL), new PagedResultsControl(pageSize, cookie, Control.CRITICAL) };
                        }else{
                             //search is finished
                             return null;
                   ctx.setRequestControls(controls);
                   //ctx.getEnvironment().values();
                   //ctx.getEnvironment().put("com.sun.jndi.ldap.connect.timeout", "5000", 300000);
                   ctx.addToEnvironment("com.sun.jndi.ldap.connect.timeout", "0");
                   //ctx.getEnvironment().values();
              } catch (NamingException e) {
                   Tracer.getInstance().error("Paged Search failed while setting response controls: " + e);
                   return null;
              } catch (Exception e) {
                   Tracer.getInstance().error("Paged Search failed while setting response controls: " + e);
                   return null;
              //2.step: DO SEARCH
              for(int i=0;i<10;i++){
                   boolean reconnect=false;
                   try{     
                        results = ctx.search(searchBase, searchFilter, searchCtls);
                        Thread.sleep(300000);
                        //ctx.get
                        //Thread.sleep(300000);
                        break;
                   } catch (NamingException e) {
                        Tracer.getInstance().error("Paged Search failed : " + e);
                        reconnect=true;                    
                   } catch (Exception e) {
                        reconnect=true;
                        Tracer.getInstance().error("Paged Search failed : " + e);                    
                   if(reconnect){
                        try {
                             this.ctx = LDAPServer.getInstance().getDirContext();
                             ctx=ctx.newInstance(controls);
                             //ctx.getEnvironment().values();
                        } catch (NamingException e1) {
                             Tracer.getInstance().error("Could not reconnect the ldapcontext");
              return results;
         }

    It turned out to be a DirX "root DSE" entry "PAGP" that is disposing my paged results if a timeout occurs(300 seconds by default).
    So i have to modify this entry during runtime, which is unfortunately only can be accesed by dirxadm.exe.
    Is it possible to modify this attribute by a ldap context method?

  • Could not open error log file ''. Operating system error = 5(failed to retrieve text for this error. Reason: 15105).

    Hello
    When I try to start the SQl server service i get the following error:
    Event id 17058
    Could not open error log file ''. Operating system error = 5(failed to retrieve text for this error. Reason: 15105).
    As a test I have made sure the errorlog file ,and the entire drive it is, has everyone full control permissions, but to no avail. Does anyone have any ideas to resolve this issue?
    Thank you

    Hi,
    Try running:
    SELECT SERVERPROPERTY('ErrorLogFileName')
    Then verify that the account being used to run the SQL Server service account has access to the path output above.  If possible, you could try logging onto the server with the same account used to run SQL Server then navigate to the errorlog folder.
    Thanks,
    Andrew Bainbridge
    SQL Server DBA
    Please click "Propose As Answer" if a post solves your problem, or "Vote As Helpful" if a post has been useful to you

  • ERROR CODE 1962 - NO OPERATING SYSTEM FOUND

    My B540 continues to experience intermittent problems with Error Code 1962-No Operating System Found.  Sometimes the computer will run correctly for 3 or 4 days, other times for just an hour, but in the end it repeatedly locks up and will not reboot.  If I check the Bios Setup immediately after this happens, it says that there is no HDD.  However, if I wait for an hour or two with the computer off, it will boot.
    1. The logical explanation is that the HDD is faulty, but that is not so in this case.  In addition to the HDD that came with the computer, I have tried two other HDDs, both brand new, never used, and both with fresh Win 7 installs.  Both of those ended up with the same Error Code 1962.  There is no way that all three HDDs could be defective.
    2. I removed and reseated the memory.
    3. I ran extensive diagnostic tests on the memory; it tests OK.
    4. Someone suggested plugging the HDD SATA cable into a different SATA connection, but the B540 only has two connections (one for the HDD, one for the optical drive).  I swapped those two, but still got the error code.
    I have to believe that the problem is with the motherboard.  I have noticed on the forum that other people are experiencing the same 1962 error code; has anyone found a working solution?
    Thanks!

    Ah, bummer.  Thought maybe I was onto something...
    Z.
    The large print: please read the Community Participation Rules before posting. Include as much information as possible: model, machine type, operating system, and a descriptive subject line. Do not include personal information: serial number, telephone number, email address, etc.  The fine print: I do not work for, nor do I speak for Lenovo. Unsolicited private messages will be ignored. ... GeezBlog
    English Community   Deutsche Community   Comunidad en Español   Русскоязычное Сообщество

  • Error: Unable to manipulate operating system

    In the CCM I have all services up and running, however, when I go to the CMC web page and look at the Servers, there are two servers in particular that are stopped and when I go to click on them to start I get a new page with the verbiage "Unable to manipulate operating system service for server".
    What is causing the CMC to report this "error" whilst the CCM shows the service as up and running? I am logged on the server directly running both the CCM and CMC (not both at the same time).
    My platform is XI R2 SP3.
    Thanks,
    John

    Gurusamy,
    Did you try creating new service for the same type of service?
    This is exactly what happened, on Monday morning I wound up creating a new service (actually every service except for the Central Management Server).  All other servers were sending a notice to the Apps log on the server "Fail to register with the nameserver.  Please check for name duplication and validness of name used".  Though no one in network ops is confessing, some type of naming convention was changed over the weekend causing all of our BO services to fail (except miraculously CMS).  So I followed SAP tech note #1199817 (add and start the services, delete the duplicate services), all done successfully via CCM, however, when I went over to the CMC side of the house, some of the newly established services indicated "stopped", which I found to be quite confusing, hence this post.  Tim's suggestion to delete the service in the CMC and allow it re-populate was the solution that worked.
    Thanks,
    John

  • Re: Error while Execute External Operating System Command using T.code SM49

    Dear Experts,
    I Have uploaded one .exe file in the application server (eg: sum.exe) and created the OS command in SM69 transaction .
    And maintained the application server path in the 'operating system command' field in SM69 t.code.
    Our SAP system, oprating system is UNIX.
    After I have executed the external command using transaction SM49 , but I got the below error.
    Can not execute external program (permission denied) , External program terminated with exit code 1
    Immediately I run the SU53 transaction code to check the authorization, but Authorization was successful.
    Could any one please help on this error.
    Thanks in advance.

    >>Can not execute external program (permission denied) , External program terminated with exit code 1
    You need to give the permission as 755 to your file.
    >>I Have uploaded one .exe file in the application server (eg: sum.exe)
    You are on UNIX and do not expect to any result of .exe file as UNIX doesn't know about this.

  • TS130 ERROR CODE 1962 - NO OPERATING SYSTEM FOUND

    Lenovo TS130 Ubuntu Server 14.04 Error 1962: This error occurred during the installation of Ubuntu Server on a hard drive that was completely deleted and then re-partioned using "use entire disk" option in the installation menu: No operating system would start regardless of the BIOS settings such as UEFI, legacy, auto; quickboot; etc.
    The solution was to update the BIOS to the latest version from the Lenovo website and then enable the new securboot feature in the BIOS menu.
    For the TS130, this was accomplished by burning the BIOS update on a CD after downloading for the system from the Lenovo website and then updating the server via the CD and on-screen prompts.
    The optimize BIOS defaults was selected from the Exit menu in the BIOS settings to set everything back to original before the update was run.
    Then the CD drive was moved upwards above the hard drive under primary in the boot menu to run the BIOS Update CD at boot.
    Afterwards, there will be additional options in the BIOS menu which is where the solution lies. There is a new option below the "load optimal defaults" which is new from the BIOS update and named optimize operating system defaults. Selecting this will bring up prompts asking about enabling securboot and such but if everything is enabled, the system started Ubuntu Server 14.04 without issues.
    Moderator Note; subject edited; post moved to here

    Ah, bummer.  Thought maybe I was onto something...
    Z.
    The large print: please read the Community Participation Rules before posting. Include as much information as possible: model, machine type, operating system, and a descriptive subject line. Do not include personal information: serial number, telephone number, email address, etc.  The fine print: I do not work for, nor do I speak for Lenovo. Unsolicited private messages will be ignored. ... GeezBlog
    English Community   Deutsche Community   Comunidad en Español   Русскоязычное Сообщество

  • Error al iniciar "USING OPERATING SYSTEM"

    Hola,
    Tengo un ThinkCentre Edge 72 el cual al iniciar el equipo aparece el mensaje "using operating system" y de ahí no pasa.
    He intentado entrar en la BIOS para restablecer los valores por defecto pero no entra en BIOS directamente aparece de nuevo ese mensaje.
    Alguien tiene idea de que puede ser?.
    Saludos y gracias,

    Hola RichiRS. Por lo que comentas puede ser un problema de la información contenida en el disco (particiones, sistemas de archivos, etc) y por eso el sistema operativo no arranca.
    Mi recomendación es que saques el disco y lo conectes a otro equipo (directo por cable SATA o bien utilizando un dock) para que puedas ver si tienes acceso a la información.
    Saludos.
    IPnaSh
    First Spanish Community Guru - Colaborador ad honorem

  • SCCM 2012 - Adding Operating System Installer (The specified path does not contain a valid operating system ..)

    I have encountered the dreaded "The specified path does not contain a valid operating system or you do not have permission to access it.  Specify a valid path" message that seems to be popular in many forums .... BUT, so far none of the "solutions"
    have fixed the problem (of I don't understand the fix)
    Configuration
    SCCM 2012 SP1 5.0.7804.1000
    WADK 8.100.26629.0  < Suggested Fix
    Server 2008 R2
    SCCM Administrator with UserID = SCCMAdmin 
    Steps / Fixes I have followed
    I have configured a administrative share
    \\caleb\sources$ to hold directories (such as Apps, Drivers, and OS) with the following NTFS Permissions
    EVERYONE has Read and Execute, List folder, Read permissions<o:p></o:p>
    SYSTEM has Full Control 
    <Suggested Fix
    SCCMManagers (our group that has all SCCMManagers) has Full Control<o:p></o:p>
    SCCMAdmin (the SCCM Admin account that we are using to import image) has Full Control<o:p></o:p>
    Local Administrators (the local machine administrator) has Full Control 
    <Suggested Fix
    <o:p></o:p>
    Another Fix is to explicitly grant all permissions to the SCCM Administrator
    <Suggested Fix
    >Administrative Users ...
    Properties of the SCCM Administrator (for us that is SCCMAdmin) has all the boxes checked<o:p></o:p>
    Another suggestion I was able to glean was to Specify the Network Access Account
    so I configured SCCMAdmin as the Network Access Account.
    Another potential fix is that the image ISO file that has been downloaded is corrupt.   So, I downloaded the Win 7 (and Win 8.1) ISO's from MSDN and did a Checksum check.
    I then mounted the ISO (on 2008R2 I use VirtualClone Drive) and copied the contents of the image to
    E:\Sources\OS\en_windows_7_professional_with_sp1_vl_build_x86_dvd_u_677896 for Windows 7 with SP1
    To double check,
    I computed the Hash on the Install.WIM located in the Sources directory and compared with
    the computed Has Tag for the Install.WIM on the ISO Image  ... and the Hash tag of the WIM's matched (extracted vs what is contained within the ISO)<o:p></o:p>
    I tried to load the images into SCCM 2012 using the "Operating System Installers" option
    UNC to installer
    \\caleb\sources$\OS\en_windows_7_professional_with_sp1_vl_build_x86_dvd_u_677896
    Then I receive the lovely message <o:p></o:p>
    "The specified path does not contain a valid operating system or you do not have permission to access it.  Specify a valid path"<o:p></o:p>
    <o:p> </o:p>
    From
    C:\Program Files (x86)\Microsoft Configuration
    Manager\AdminConsole\AdminUILog\SmsAdminUI.log<o:p></o:p>
    <o:p> </o:p>
    \r\nSystem.Management.ManagementException\r\nGeneric failure \r\n  
    at System.Management.ManagementException.ThrowWithExtendedInfo(ManagementStatus
    errorCode)
       at System.Management.ManagementObject.InvokeMethod(String
    methodName, ManagementBaseObject inParameters, InvokeMethodOptions options)
       at
    Microsoft.ConfigurationManagement.ManagementProvider.WqlQueryEngine.WqlConnectionManager.ExecuteMethod(String
    methodClass, String methodName, Dictionary`2 methodParameters, Boolean
    traceParameters)\r\nManagementException details:
    instance of SMS_ExtendedStatus
     Description = "Failed to get the image property from the source WIM
    file due to error 80070002";
     ErrorCode = 2147942402;
     File ="e:\\nts_sccm_release\\sms\\siteserver\\sdk_provider\\smsprov\\sspimagepackage.cpp";
     Line = 586;
     Operation = "ExecMethod";
     ParameterInfo = "SMS_OperatingSystemInstallPackage";
     ProviderName = "WinMgmt";
     StatusCode = 2147749889;
    \r\n<o:p></o:p>
    What am I missing ????  I assume something simple but, darn I'm stumped!!!

    Hi,
    Configuration Manager version
    Windows AIK or Windows ADK Version
    Windows PE versions for boot images customizable from the Configuration Manager console
    Supported Windows PE versions for boot images not customizable from the Configuration Manager console
    System Center 2012 Configuration Manager with no service pack
    Windows AIK for Windows 7
    Windows PE 3
    None
    System Center 2012 Configuration Manager with SP1
    Windows ADK for Windows 8
    Windows PE 4
    None
    System Center 2012 Configuration Manager with SP1 and cumulative update 2
    Windows ADK for Windows 8
    Windows PE 4
    Windows PE 3.11
    System Center 2012 Configuration Manager with SP1 and cumulative update 3
    Windows ADK for Windows 8
    Windows PE 4
    Windows PE 3.11 and Windows PE 5
    System Center 2012 R2 Configuration Manager
    Windows ADK for Windows 8.1
    Windows PE 5
    Windows PE 3.11
    Please try to install the Windows ADK for Windows 8.
    http://www.microsoft.com/en-us/download/details.aspx?id=30652
    For more information, please review the link below:
    http://technet.microsoft.com/en-us/library/gg682187.aspx
    We
    are trying to better understand customer views on social support experience, so your participation in this
    interview project would be greatly appreciated if you have time.
    Thanks for helping make community forums a great place.

  • AD security groups listed in user groups in Config Manager however not listed when selecting values for the "System Resource - System Group Name" query

    Morning All,
    We are in the process of setting up our SCCM 2012 infrastructure and are experiencing issues with our device collection querys based on AD security groups.
    I can see the security groups are being updated per adsgdis.log - i can see the computers that are members of the groups in AD are being recorded in the same log. Issue is when we build the device collection query - click the value button for the string,
    only 2 of the 18 AD security groups are displayed.  These are 2 AD groups we setup initially to test.
    We have since added several additional yet they only appear to populate as user groups in config manager.
    The same goes for additional OUs that we have created with AD.
    When i click the value button only the initial 10 OUs that were created are populating in the list of applicable OUs.
    We have the discovery methods Group Discovery & System Discovery enabled and set to search the parent OU recursively
    I'm wondering if there might be an SQL issue with this as it initially worked but stopped...
    Additionally we added an OU recently that now appears in in the Values options in the query but the ones added previously and additionally after are not showing up....
    Any help is appreciated.
    Thanks,
    Jeff

    Given the adsgdis.log lists the new pc and the group it's assigned to it appears the AD group discovery is working.
    Have the following excert from the adsgdis.log
    INFO: Processing discovered group object with ADsPath = 'LDAP://************.****.COM/CN=Software - Microsoft Project Professional 2010 x64,OU=Software,OU=US-West,DC=*****,DC=com' SMS_AD_SECURITY_GROUP_DISCOVERY_AGENT 10/4/2012 7:08:13 AM 8180
    (0x1FF4)
    INFO: DDR was written for group '*****\Software - Microsoft Project Professional 2010 x64' - E:\Program Files\Microsoft Configuration Manager\inboxes\auth\ddm.box\userddrsonly\asg8ud94.DDR at 10/4/2012 7:8:12. SMS_AD_SECURITY_GROUP_DISCOVERY_AGENT 10/4/2012
    7:08:13 AM 8180 (0x1FF4)
    INFO: DDR was written for system 'THURMANWIN7VM' - E:\Program Files\Microsoft Configuration Manager\inboxes\auth\ddm.box\adhh8419.DDR at 10/4/2012 7:8:12. SMS_AD_SECURITY_GROUP_DISCOVERY_AGENT 10/4/2012 7:08:13 AM 8180 (0x1FF4)
    Here you can see it processes the new members in the Software - Microsoft Project Professional 2010 x64 group and captures Thurmanwin7vm as a member.
    I did find some log entries that reference permission issues with objects in the SQL database and have opened a case with MS to get that looked into.  Hopefully that will be where the issue lies.

  • Error with widows 7 Operating system

    1."Microsoft Visual C++ Runtime Library Runtime Error" error message on IE browser 
    2.System.OutOfMemoryException: Exception of type System.OutOfMemoryException was thrown.

    Hi,
    One: "Microsoft Visual C++ Runtime Library Runtime Error" error message on IE browser 
    Hava you tried running IE in No Add-on mode?
    Please try re-installing Microsoft Visual C++ Runtime Library:
    http://www.microsoft.com/en-us/search/DownloadResults.aspx?q=Microsoft%20Visual%20C%2B%2B2010
    Two: System.OutOfMemoryException: Exception of type System.OutOfMemoryException was thrown.
    Please refer to the article below:
    http://blogs.msdn.com/b/ericlippert/archive/2009/06/08/out-of-memory-does-not-refer-to-physical-memory.aspx
    Andy Altmann
    TechNet Community Support

  • Error 4960/103 mac operating system

    I downloaded the trial several times in different places: desktop, new folders etc. It downloads the product showing the % of completion then gets to extracting files this might take a while and does not finish. what is going wrong after it downloads?

    Yep this is completely expected behavior for choosing to download the install files to the Application folder.  Please choose the default of your User folder or your desktop.  The Adobe Download Assistant does not have sufficient rights to write install files to the Application folder.
    Once the download is complete the installer will be launched and then install the Application files to the Application folder.

  • OIncomingPayment + BillOfExchange = error -5002 - Invalid dll path or name

    Hi for all,
       I´m having a problem when I try to pay a incoming payment from a invoice with BillOfExchange, I´ve been search all this forum for many hours, with all possibile combinations of subject, but any past topic could explain this problem.
       When I try to add a BillOfExchange of one invoice, I´m getting the error -5002 called 'Invalid dll path or name'. I know that the PaymentMethod that I use references the BankOfBrazil.dll library, but how can I handle this error? I´ve tried to put this file on my projects folder, but It wasn´t works...
       Here´s the code, I´m using the SAP B1 2005B PL36:
       Thanks
                'oIP = oIncomingPayments
                oIP = oCompany.GetBusinessObject(SAPbobsCOM.BoObjectTypes.oIncomingPayments)
                chave = oIP.DocEntry
                oIP.CardCode = oBP.CardCode
                oIP.CardName = oBP.CardName
                oIP.DocDate = Now
                oIP.DueDate = Now
                oIP.TaxDate = Now
                oIP.Invoices.AppliedFC = 0
                oIP.Invoices.DocEntry = oInvoiceIn.DocEntry
                oIP.Invoices.InvoiceType = 13
                oIP.Invoices.SumApplied = 5.85
                oIP.Invoices.InstallmentId = 1
                oIP.Invoices.Add()
                 oIP.BillOfExchange.PaymentMethodCode = oInvoiceIn.PaymentMethod
                oIP.BoeAccount = "1121110"
                oIP.BillOfExchangeAmount = 5.85
                '**** Commita ****
                lErrCode = oIP.Add 'Occours error -5002
                connmatriz.getConn().GetLastError(lErrCode, sErrMsg)
                If lErrCode <> 0 Then
                    connmatriz.getConn().EndTransaction(SAPbobsCOM.BoWfTransOpt.wf_RollBack)
                    GoTo FALHA
                End If

    HI
    I have also got several times same message:
    1. Disconnect with development environment
    2. Clear the SM_OB_DLL directory from the TEMP directory.
    3. Start it again, and try
    In the BankofBrazil stuffs i am so perfect....
    Regards,
    J.

  • The user or group name is not recognized. (rsUnknownUserName) error

    Hi All
    i have create a group name Finance using these steps.
    my computer rightclick -> manage->create group -> add user
    now i add this in reportmanager ->sitesetting -> domainname\Finance.
    but getting an error..
    "The user or group name 'domainname\Finance' is not recognized. (rsUnknownUserName) "
    I also tried to give permission to user those in active directory but getting the same error.
    Kindly Help

    What permission did you give to that account in the Report Manager?
    Best Regards,Uri Dimant SQL Server MVP,http://sqlblog.com/blogs/uri_dimant/
    Blog : MS SQL Development and Optimization
    Blog : Large
    scale of database and cleansing

  • BDD 2007 -- ZTI -- OSD error "The Operating System Installation Failed Unspecified Error (80004005)

    Hi there
    Wonder if anyone can advise me on a BDD 2007 OS deployment issue? (Apologies if this is in the wrong forum, I couldn't see a forum for BDD 2007.)
    First of all, this BDD 2007 server and the OSD config was not done by me. For info, it is part of a SMS 2003 infrastructure.
    I am trying to get the XP Pro build process working. I am led to believe the config has been completed.
    Unfortunately, after booting the pc from the nic, I get an error. This is the order:
    - the 'Initializing Windows PE' splash appears for perhaps 15 seconds
    - very briefly, the text changes to 'Initializing Network'
    - for a second or two only 'Initializing Windows PE' appears again
    - then this error message appears:
    "SMS Operating System Deployment - The Operating System Installation failed. Please contact your system administrator for assistance. Unspecified Error (80004005)"
    I've spent some time looking into this error (80004005) and from what I can gather it possibly means 'access denied'.
    I'm assuming after Windows PE loads the first Task Sequence begins, and if this possibly is where the issue lies?
    One thing I cannot understand - the first Task Sequence (Initialization) has this command line (as do most, with different .wsf file):
    cscript.exe "%SCRIPTROOT%\ZTIGather.wsf" /localonly
    However, I cannot access %SCRIPTROOT% at all, Windows says it can't find it. I can run other variables such as %USERPROFILE%, %SYSTEMROOT%, etc, but cannot open %SCRIPTROOT%.
    Is it simply the case that I should create a new system variable (that has not been created by whoever built the server)?
    Thanks
    John Henry

    Since no one has answer this post, I recommend opening  a support case with CSS as they can work with you to solve this problem.
    Garth Jones | My blogs: Enhansoft and
    Old Blog site | Twitter:
    @GarthMJ

Maybe you are looking for

  • Can't see phone in File Manager

    Hey. Bought a new Nokia 2730 today and managed to get some music into it. Everything worked fine so far; the phone has connected without any problem, I can see it in PC suite and all that things. But when I select File Manager, there is nothing. I ca

  • Strange repaint behaviour with JList & Keyboard actions

    Hi everyone, This is my first post to the forum. You guys have been a great help in the past and I hope to contribute more in the future. Anyways, I've encountered some strange repainting behaviour with a JDialog that uses a JList and a JButton. The

  • Configuring OAM audit database

    Hi Gurus, I am trying to configure audit database for OAM 11.1.1.5, i am following http://download.oracle.com/docs/cd/E14571_01/doc.1111/e15478/audit.htm#BABHAJCB this document. I have created a audit database using RCU then created a data source(Aud

  • --uuid restore & multiple server pools

    Greetings, Greetings, we have a 3.1.1 environment with 4 disparate server pools (105 servers - 400+ VMs) managed by one centralized Oracle VM Manager host. Each server pool is in a different data center. We would like to decentralize the management o

  • Trabajar con Multicolumn Listbox

    Hola a todos...mi pregunta es la siguiente: me encuentro realizando una aplicación donde almaceno en una base de datos el nombre de unas variables (temperaturas), mas no el valor. en la primera columna muestro los datos de un Select que hago a una ta