Error setting cookie while login process
Dear forum users,
i am getting this error while login into my own application.
Content-type: text/html; charset=ISO-8859-1 Set-Cookie: DHW_COOKIE=EEDD257F53989F57; path=/; Location: f?p=100:1000:155225166267009
I am using a process on submit after computation. This process is before the login process.
10: set Cookie
20: login
This source would setting the cookie before login:
declare
p_text_raw RAW(128);
p_key RAW(128) := utl_raw.cast_to_raw('Key88888');
p_crypto_typ NUMBER := dbms_crypto.des_cbc_pkcs5;
p_encrypted_raw RAW(2048);
p_decrypted_raw RAW(2048);
begin
-- Benutzername und damit den Cookie-Inhalt verschlüsseln
p_text_raw := UTL_I18N.STRING_TO_RAW (lower(:P100_USERNAME), 'AL32UTF8');
p_encrypted_raw := dbms_crypto.encrypt(
src=> p_text_raw,
typ => p_crypto_typ,
key => p_key);
-- Verschlüsseltes Cookie senden
owa_util.mime_header('text/html', FALSE);
owa_cookie.send(
name=>'DHW_COOKIE',
value=>p_encrypted_raw);
owa_util.http_header_close;
exception
when others then null;
end;
Any ideas for this error ?
regards
Frank
Hello community,
any comments ?
Edited by: handwerk.net on Dec 16, 2009 7:31 PM
Here's one more reason why this error occurs in Toad. It is when you have more than one Oracle Client installed on your machine. Even when you select the correct Oracle Home in "Connect Using" field of Toad, you still get this error "Can't initialize OCI. Error -1". So, to solve that you need to go to the installation folder of that Oracle Home (e.g. C:\Oracle\ora92\), then go to the BIN folder. Open Oracle.Key in Notepad and confirm that it is showing Registry entry/path to the correct Oracle Home (e.g. HOME0 or HOME1 or whatever).
I hope this helps.
Similar Messages
-
Error occurred during the login process
Error: A connection was successfully established with the server, but then an error occurred during the login process. (provider: Shared Memory Provider, error: 0 - No process is on the other end of the pipe.) (.Net SqlClient
Data Provider)Step 1: Open SQL Server Configuration Manager
Go to Windows 8 Start screen.
Start typing in SQLServerManager11.msc if you are looking for SQL Server 2012 configuration manager. Type in SQLServerManager10.msc if you are looking for SQL Server 2008 configuration manager.
In the result panel you can see the SQLServerConfiguration Manager.
Click the icon to launch the SQL Server Configuration manager.
The configuration manager will open in MMC.
Step 2: Enable following configuration settings
ensure Shared Memory protocol is enabled
ensure Named Pipes protocol is enabled
ensure TCP/IP is enabled, and s ahead of the Named Pipes in the settings
http://dotnetguts.blogspot.com/2014/05/a-connection-was-successfully.html?utm_source=feedburner&utm_medium=feed&utm_campaign=Feed%3A+DotnetGuts+%28Asp.net%2C+C%23%2C+.Net+Framework%2C+SQL+Server+Information%29
Ahsan Kabir Please remember to click Mark as Answer and Vote as Helpful on posts that help you. This can be beneficial to other community members reading the thread. http://www.aktechforum.blogspot.com/ -
Can't initialize OCI error occured during the login process using TOAD 9.0
I have installed the Toad 9.0 recently while login using the username & password for oracle 10.0 database , i am getting the error
Can't initialize OCI Error 1
But i am able to login using the Sql Plus successfully..
Thanks in Advance.Here's one more reason why this error occurs in Toad. It is when you have more than one Oracle Client installed on your machine. Even when you select the correct Oracle Home in "Connect Using" field of Toad, you still get this error "Can't initialize OCI. Error -1". So, to solve that you need to go to the installation folder of that Oracle Home (e.g. C:\Oracle\ora92\), then go to the BIN folder. Open Oracle.Key in Notepad and confirm that it is showing Registry entry/path to the correct Oracle Home (e.g. HOME0 or HOME1 or whatever).
I hope this helps. -
Version incompatibility error in OWB while login to Design Center
Hi,
I have created a Warehouse Builder repository on database(Version 11.1.0.7) server and installed Standalone OWB 11.2 on the client machine. However while connection from client pc it is throughing error like:
API5036: client version 11.1.0.6.0 is not compatible with repository version 11.1.0.7.
Please help me on this issue.
Thanks.
vinod
Edited by: Vinod Ranjan on 27 Dec, 2011 11:32 PMYou need to access the repository version with a compatible client.
Which OWB version are you trying to use?
There is a section below on using the standalone install which will let you use OWB 11gR2 for example with a 10gR2, 11gR1 or 11gR2 database.
http://docs.oracle.com/cd/E11882_01/owb.112/e17130/setup_windows.htm#CHDGDCGD
Cheers
David -
Why is the Error Code 0x8002006E While Burning the Disc?
Hey there! I don't seem to get through this Issue. I was trying to burn content to a Disc and it failed with the error code 0x8002006E, while the process was almost complete. I came across a few forums and nothing helped much to resolve this problem. Is there someone who knows the exact cause? Is this is a known-issue or anything already being addressed by Apple? Or a work-around to get this resolved? because i also read (did not try) that no third-party applications, as an alternative, solved this Issue. Disappointed! Help!
Model: iMac (21.5-inch, Mid 2011)
OS: Lion OS X 10.7.4
I have the latest software updates and Firmware updates installed.
Thank you,
Sivarama Krishnan (kvsrkrishnan)
<Edited by Host>I found this article excerpt:
The few solution that where found where by calling at Apple and get technical support. There are a few solutions that might work.
The first one would be Go to users > your computer name / user name > library > Preferences > com.apple.finder.plist and delete this file. Also it’s advised to keep the burn speed at 8x.
The second solution found that Apple technical support gave is to unplug everything, including the AC power cord and then remove the battery. Press the power button for 10 seconds without replacing the battery or attaching the AC power cord and after the 10 seconds are up replace the battery. After the battery is in slot hold down the following keys with the left hand: Option + Apple (command) + R and with the right hand hold down the following keys: P + Power Button. You will need to hold all 5 of these buttons at the same time until you hear both sets of startup chimes Release all of the 5 buttons after you hear the two startup chime sounds.
Hope this helps -
Exception occurred while TADIR processing (/IWFND/MED200).
I am trying to set up the HCM ESS UI5 scenario which is based on Gateway. Now I have a problem with two services. Anyhow these services are not assigned to a model and they are not of type BEP, the backend type field is empty. See attached screenshot of /IWFND/MAINT_SERVICE.
Now I tried to delete the services and create it newly. But when I push the delete button I get an error “Exception occurred while TADIR processing”
(/IWFND/MED200).
Does anyone know how I can delete the services?
Or is it possible to add the model and the BEP assignment to an existing service?
Thanks for any help!
Best Regards
ChristianHi Chandra,
thanks for your quick answer but unfortunately I can't do it that way.
I cannot delete the backend service and model as these are SAP standard from the ESS scenario.
Also I do not have a project in SEGW, I only activated the existing services in /IWFND/MAINT_SERVICE. Obviously I did something wrong at that step...
I try to do some debugging now, maybe I'll find the reason for the error!
Best Regards
Christian -
Error "Lock not set for: Generate index" while running process chain
SAP BI 7.0
SP 17
I am attempting to run a new process chain and the generate index steps are failing with the below errors:
"Lock NOT set forGenerate index"
"RSSM PROCESS INDEX terminated, because InfoCube/DSO object could not be locked."
The process chain just pauses. I let it finish once and it took 2 hours and then it gave the failure messages. I have looked in sm12 and can see the lock records when the process chain is running - unfortunately I can't make much of what's there - everything looks good to me. I also tried creating the indexes manually inside the cube and then re-ran, but still get the same error. Before running the process chain, I can get the indexes to check to green, but then after running the process chain they go back to red. I have attempted many things (including looking at other forum posts), but I still have the error. Please help. Thanks
Edited by: Brett Hutchinson on Feb 10, 2009 7:50 PMHello,
So Create index is getting failed in you PS right?
1)check if any other loads are running to the same CUBE(May be from other PC's also)
Goto Manage of the cube and check, some times it may happen if any Loads are running into cube I mean Load/DTP & roll up may be running.. if so wait till the others Loads(Jobs) get complete then Repeat the failed index
2) If the Create index is running for long time, then got RSDDV--> Select the CUBE then click on BIA index(Maintenance wizard), you can see a message if indexes are running , this will happen only when some one would have tried to generate the indexes manually and it may got failed due to some reason , since u are running it manually u couldn't identify whether it got failed or not unless you got to RSDDV and check. So delete the index here and then rebuild them through PC
Hope it helps! -
Error has occurred while processing your request reference #...
Every time we go to login into a particular site get the message an error has occurred while processing your request and give a reference number. This happens while using both browsers Safari and Firefox. I've cleared history and cookies/cache. Nothing seems to work. any suggestions?
The problem is at the server end.
-
Run time error while login to RTF Template
Hi,
I am trying to create a sample report in BI Publisher. but while login into RTF Template I am getting below error.
Please rectify this problem?
Run time error '429'
Active x component can't ceate object
help me outRuntime Errors DYNPRO_FIELD_CONVERSION
Date and Time 07.05.2010 08:49:15
ShrtText
A conversion error occurred.
What happened?
The current screen processing was terminated, since a situation
occurred from which it could not continue processing.
This is probably due to an error in the current screen of the ABAP
program.
What can you do?
Make a note of the actions and input which caused the error.
To resolve the problem, contact your SAP system administrator.
You can use transaction ST22 (ABAP Dump Analysis) to view and administe
termination messages, especially those beyond their normal deletion
date.
Error analysis
The program flow was interrupted and could not be resumed.
Program "SAPMJ1IFN" tried to display fields on screen 1210. However, an
error occurred while this data was being converted. -
I can not login to a certain account due to an error stating cookie not enabled, however my 3rd party cookies are enabled. How do I correct this?
COOKIE_DOMAIN=.hackers
I think this is the problem. .hackers is no valid cookie domain. You have to use something like:
.xy.ab
(two points)
I fear it is not possible to correct this easiely. First change the hostname to something allowed e.g. hackers.com
Then open an ldap browser and edit ou=iplanetamplatformservice,ou=services,dc=hackers
There is an entry with an xml. Copy the xml to an editor, search for .hackers, change it to a valid domainname.
Im not sure if a restart of the webserver is necessary here.
Another idea: You could also try to set the cookie domain to solnce.hackers, maybe this is accepted, even if it is not a cookie domain. But I dont know if this works...
hth
Chris -
An error was encountered while processing images
Huge document, full of pictures and graphics. Created in Word for Mac 2011. Saved as pdf it's 38M.
When I try to reduce the size, I get an error, "An error was encountered while processing images".
No other info. Any clues?It would help to know what version of Acrobat. However, the better way is to probably work with the WORD file first. You might want to work on a copy so that you don't mess up the original. If you select a graphic in WORD, go to the format tab and select Compress Pictures. You might select the options and use 150 ppi or the 220. Many people use graphics with dpi in the thousands that the human eye can not see. You might also consider reducing the color depth from millions to 256 colors, or even 16 colors if a simple line drawing or such (this would probably have to be done to the graphic itself). If you uncheck the button to apply to the selected item, then the change will be applied to all figures (other than the color depth that can not be done this way).
Another item that makes a PDF huge are tags. Tags are good for accessibility or going back to WORD (not a good idea in general), but take a lot of space. For the smallest reasonable PDF print to the Adobe PDF printer (this will not create tags or bookmarks) with at least the Standard settings (not embedding fonts is typically a bad idea -- though you might want to be careful about using lots of different fonts in your DOC file). If you use PDF Maker (the Acrobat tab in WORD), you can set the preferences about tags and the level of bookmarking in the PDF. All of this can help in creating a reasonable size PDF. For such a large PDF, the print root might be best. If you are careful, there should be no need for 38M. -
Hi all,
I'm facing a problem while login into ESSO Provisioning Gateway, it throws error "Cannot connect to "AD" data repository. Your username or password may be incorrect.". My Provisioning Gateway version is 11.1.1.5.2 and it is freshly installed. It throws error while I try to set event log in PG setting menu. The symptom is really like document with ID 467150.1 in Oracle Support but my storage is Active Directory as had mentioned above not Oracle Internet Directory. Have anyone ever faced problem like thisOIM? Any help will be very much appreciated. Thanks
Regards
Johan SaragihI use only support.mozilla.org and never used any other websites. However, the same problem here. My ID and Password are not accepted. Had to create a new account with a temporary email to use Support - it would not allow me to use my main email, because "it is used by another account". Try to reset password - receive no email (even though there is a confirmation on the website that email to reset password has been sent). At the same time can easily receive a confirmation about User ID and account activation. Thus, the account is completely locked, and I can not use my email address for a new one. Please fix this problem.
-
GETTING ERROR MESSAGE"You cannot login because the phone is JAL-enabled' while logging into CAD
Hello All,
One of my customer is facing problem while loging into CAD. They were getting an error message"
You cannot login because the phone is JAL-enabled.
JAL-enabled phones are not compatible with CAD".
I gone through some cisco document saying that Join across line/Direct transfer across policy option status should be set to OFF. But i dont find option in 9971 series phone.
Any Reply for this query. Highly Appreciated.That's because the JAL function is inherent to the 8961/9951/9971 phone and cannot be disabled. You'll need to upgrade to a release that supports this phone model or use a different phone.
Please remember to rate helpful responses and identify helpful or correct answers. -
Hi,
I m getting error while login to Infoview
u201CAn error has occurred: recv() failed:I/O error during read:java.net.SocketException: No buffer space available (maximum connections reached?): recv failedu201D
CMC is working fine.
We have tried restarting Tomcat.
Checked the available space on the installation directory as well on C drive, there was enough space.
Checked the temp directory of the user who installed Business Objects.
Checked the virtual memory size on the system, increased the Heap size to 1024.
Please suggest how to proceed further.
Thanks,
AnisaHi Anisa,
The above error was caused in windows If you try to set up TCP connections from ports that are greater than 5000, Try the below solution
Start Registry Editor.
Locate the following subkey in the registry, and then click Parameters:
HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Services\Tcpip\Parameters
On the Edit menu, click New, and then add the following registry entry:
Value Name: MaxUserPort
Value Type: DWORD
Value data: 65534
Valid Range: 5000-65534 (decimal)
Default: 0x1388 (5000 decimal)
Description: This parameter controls the maximum port number that is used when a program requests any available user port from the system. Typically , ephemeral (short-lived) ports are allocated between the values of 1024 and 5000 inclusive.
Exit Registry Editor, and then restart the computer.
Hope this helps,
Regards,
Santhi Bushan -
A communication error has occurred while invoking commands in SharePoint host process
Hi All,
I am using Virtual box to connect to Sharepoint 2013 VPC. Due to an unexpected sutdown of my machine the VPC got some issue. Now I restored it using my bak up file. But after this when I deploy my sharepoint 2013 farm solution Iam getting the following error.
Error occurred in deployment step 'Recycle IIS Application Pool': A communication error has occurred while invoking commands in SharePoint host process: The server did not provide a meaningful reply; this might be caused by a contract mismatch, a premature
session shutdown or an internal server error.
What could be the issue? Any suggestions ?
Thanks in advance...
Regards
Nimisha
[email protected]Hi Nimisha,
Seems that the original issue of communication error has been solved, for this new issue, it is recommended that you open a new thread which can make others easier
to focus on one issue in one single thread.
Best regards,
Patrick
Patrick Liang
TechNet Community Support
Maybe you are looking for
-
I am having the worst trouble with two things. I am very aware how to get the server to show up via SMB, but every time I log off the Macbook, the server's disappear. OK, so I went into "System Preferences" and hit "Users and Accounts" and added the
-
Hello again. First of all excuse me if I mistype anything or fail to use some terms correctly. English is not my mother tongue and I am kind of new to MacBooks. Here's my problem. I've got a macbook pro (yosemite 10.10.1, retina, 15", late 2013, 8gb
-
Problems logging in to get my trial version of Acrobat XI Pro
I'm trying to log in to my trial version of Acrobat pro but it keeps logging in on an old email address, doesn't give me the option to change it and says I need to license it when I haven't even used it yet! I have uninstalled it and re-installed it
-
I took the plunge and upgrade my ipad and 6 + to IOS 8.3. I am no long able to connect to the exchange server at my office. Does anyone have a hint or solution? TIZ
-
Can i delete standard Adobe's Script from editor?
Hello I put a around 60 drop down fields in my_subform in my_form, well. Now, the requirements got changed, hence i need to change all of them into a TEXT FIELDs, so instead of deleting all drop downs and placing again 60 new text fields, my idea is