Hi, i'm new in lab view. i'm using 3'rd party daq card to get data using labview

i'm still green in this field. can anybody help me on how to get various data from daq card(not an ni brand) using my labview programming. i use labview 6 and i don't know how to get the data so i can display it in my programming. i used Pcl 1800 and pcl 836 card of advantech brand.

Greetings,
Below is a link to a KnowledgeBase, which discusses your options:
http://pong.ni.com/public.nsf/websearch/F3009806E2AE416E8525645D0076B962?OpenDocument
It appears that Advantech has a LabVIEW driver available. Below is a link to information about the driver on their Web Site. I would suggest trying this option, as opposed to using the Call Library Function with Advantech's driver DLLs:
http://www.advantech.com/content/0000000175/0000000175.asp?css=corp&name=corp
Good luck with your application.
Spencer S.

Similar Messages

  • Completely new to lab view and need to get some stop watch help please

    OK I am new to lab view so please be patient with me. I have a need for a stop watch that is triggered to start when two voltage values differ by more than 0.110V and then stop counting when they return to within 0.110v my goal is to capture the total amount of time the two voltages differ and record it along with the rest of the data is this possible and how would I do it? Thanks I am running 8.5

    danger831 wrote:
    thanks for the quick response but thats not really enough info to help me as I am very very unfamiliar with lab view and have only been using it for a few days(mainly just plugging in copied sections) so hopefully someone can give me a little more help. But the good news is I am now looking into taking one of the Lab view courses but that probably won't help me with this problem this week. thanks again for your help
    For starters, try to write the name correctly. It is LabVIEW, not lab view.
    Seriously though, your best way of learning to is try some things yourself first. Look through the examples that ship with LabVIEW for the components Raven suggested (while loops, shift registers, etc.) We could give you a working example but you will learn far more by trying things for yourself. As suggested, try a few things and then post what you have done and what you are having trouble with. From there we can answer your questions rather than just do it for you.
    Mark Yedinak
    "Does anyone know where the love of God goes when the waves turn the minutes to hours?"
    Wreck of the Edmund Fitzgerald - Gordon Lightfoot

  • Hello! Pls can anyone help. I am new to Lab view, having three(3) input variable entering a tank at the same time, but they not mixed?

    Pls, i really need help. I am having three (3) input variables entering a tank at the same time,but not mixed, they mixed only inside the tank. I assumed the tank to be an indicator then used bundle/unbundle didn't solve. I tried build array but still no solution. Thanks

    Abul, I would recommend posting in that other thread to follow up on your issues from before.  Also your problem is not very clear.  You may want to expand some more on what your issue, and a post a screen shot or a VI.
    Good Luck,
    Paul
    Paul Davidson
    Sound and Vibration Software Staff Product Support Engineer
    National Instruments

  • Dc input offset voltage, bias current using lab view

    hi all
     my lecture has asked me to write a lab vbiew program that can measure the 741 operational amplifer dc input offset volage, its bias current. i totally do not have an ideal how to do this because i am new to lab view programming.
     i have design the hardware and connected to using the ni elvis instrument, but i do not know how to write a lab view program that can help me take these. readings without been done manually using and oscilloscope.
     please help guys

    Hello augusta,
    Many thanks for your post, I have some information that I think you will find useful.
    The link below is a link to our LabVIEW Getting Started page that will allow you to get to grips with the LabVIEW environment and basic programming.
    http://www.ni.com/gettingstarted/labviewbasics/
    In terms of ELVIS, the following link may also help
    http://zone.ni.com/devzone/cda/tut/p/id/12964
    In terms of example coding, using the Find Examples from the LabVIEW getting started screen and then using Hardware Input and Output>> DAQmx>> and then selecting one of voltage examples there will also be if use.
    Many thanks and good luck!
    Liam A.
    National Instruments
    Applications Engineer

  • Video freezing up while running Lab View 10

    I am using Lab View 10. My video will freeze up every so often. Somtimes labview will abort by itself? I can run other applications while lab view is frozen. Is it a lab view programming problem or a possible video card problem. The main VI is 1.7 MB. I am running Windows Xp 32 bit. CPU 2.4 Gig, Memory 4 gig, Video Nvidea GeForce 8400 GS. It appears to be a video refresh problem. I can have a screen with two different application screens on top of each other. Can someone confirm that the video card is the issure?
    Any suggestions would be helpfull.
    Solved!
    Go to Solution.

    I'm having trouble understanding the exact behavior of 'Video' on your system. Are you having trouble displaying specific VIs? (Controls/Indicators, Updates on the Front Panel, Etc) Are you seeing generalized glitches only when running LabVIEW? If you can provide further detail on the behavior, it will be very helpful in providing meaningful troubleshooting steps of the system. 
    Thank You, 
    Patrick Corcoran
    Application Engineering Specialist | Control
    National Instruments

  • Getting error messages upon startup after installing Lab View 5.1.1.

    I have recently purchased a DAQ system along with a computer, which uses a readout program written in Lab View. however, after installing Lab View 5.1.1 on this same system, I started getting some error messages and the readout program no longer works. Here are the error messages:
    "The \SystemRoot\system32\drivers\nidmmk.dll device driver could not locate the entry point ?single PointWrite@mdsSimpleDIGPortPrimitive@@UAEXKKKAAJ@Z in driver Nidaq32K.sys"
    as well as
    "The ordinal 2011 could not be located in the dynamic link library nidaq32.dll. An error occurred while loading VT Digital buffer write.vi"
    I would greatly appreciate any help I can get.

    Hello,
    Installing LabVIEW should not effect an installation of NI-DAQ. However, it seems to me that we may have installed a different version of NI-DAQ on top of the current version. This is very possible because the old LabVIEW CD�s contain NI-DAQ on them.
    In this case, there is not an easy solution, we could try uninstalling and reinstalling combinations, but it will probably save the most time and effort to uninstall all National Instruments products and reinstall them. The best way to do so is from the ADD or REMOVE Programs utility from the Control Panel. Then we want to remove the following registry keys (BE SURE TO BACKUP YOUR REGISTRY!!)
    HKEY_CURRENT_USER\Software\National Instruments <-- Delete the entire tree!
    HKEY_LOCAL_MACHINE\Software\National Instruments <-- Delete the entire tree!
    HKEY_LOCAL_MACHINE\System\CurrentControlSet\Enum\PCI\ or \ISA and delete registry entries containing any keys with 1093 in them.
    Do not worry if any of these trees are not listed. If you have Administrative rights, and you still cannot delete these keys, that is also OK. Continue with the remainder of the process.
    Make sure that you do not have any of your own VIs or other files saved in the "C:\VXIpnp", "C:\Program Files\National Instruments", or "C:\WINDOWS\nidaq" folders. If you do, copy them to a different location. If you are concerned about keeping old virtual channels and your SCXI setup intact, then backup the "C:\WINDOWS\niconfig.daq" file, too. Delete all folders and files mentioned above.
    Note: If you have Windows NT/2000, replace "C:\Windows" with "C:\WINNT" in the paths listed above.
    Once these steps are taken care of, we should have clean system. You probably want to reboot and then reinstall the software. You should install development environments first, and then install drivers.
    Just let us know if this does not take care of the problem, or if you have any questions on how to complete a step of the process.
    Best regards,
    Justin T.
    National Instruments
    NOTE: Turning off virus scan programs greatly increases the speed of uninstalling and reinstalling.

  • Getting data from HD with cable to new Laptop

    I was unable to fix my PB G3 firewire. I am now trying to use an ATA to usb cable to get data off of the PB HD. After attaching and plugging in, I don't hear the HD spinning and the new MacBook Pro will not recognize it. Does it need a power source? Is the HD dead or cable bad? It was spinning before I took it out. Would a HD enclosure work? Thanks for any help.

    B Rob,
    I can't recall...are you sure the HD was working the last time the Pismo(?) was run?
    Read through this tutorial on mounting troublesome USB devices:
    http://www.macfixit.com/article.php?story=20070824012114701
    A few points in the tutorial:
    -Firmware update: this relates to the USB chipset in the cable system; I have no idea how you would find out which chipset is being used and if there were an update available; I would disregard this.
    -Reset NVRAM/PRAM: I would definitely try the reset with the USB HD disconnected.
    -Since your MacBook is brand new, I doubt the other suggestions would help except USB Prober; I've never used it.
    I have read of some MacBooks/MacBook Pros not supplying enough USB bus power to get the HD to mount; little you can do with your adapter cable. If nothing above works, I would definitely go with a FireWire HD enclosure, one with the Oxford 911 chipset. Here is one example:
    http://eshop.macsales.com/item/Other%20World%20Computing/MOTGFW400OB/
    If you wanted to cover your bases, you might consider the FireWire/USB HD enclosure:
    http://eshop.macsales.com/item/Other%20World%20Computing/MOTGFWU2/

  • Lab View crashing when creating new bound variable

    Hi,
    I have to connect to an OPC server from Lab view and have played around a bit with the OPC client options.
    I would like to use shared variables as that seems like a handy way to access the needed variables. I have followed the instructions in http://zone.ni.com/devzone/cda/tut/p/id/7450 .
    However when i use the create bound variables feature LabView crashes when i browse for OPC tags, step3 under "Create Shared Variables that Connect to the OPC Tags through the I/O Server". If i try to expand the node "OPC1" LabView crashes. I try to access the built in NI OPC server locally.
    Also during this process LabView gives warning box saying "Configure OPC server to run with an identity of interactive user". we did try the the steps in http://zone.ni.com/reference/en-XX/help/371618G-01/lvdschelp/config_local_opc_serv/ . However the The interactive user button was disabled under NI OPC sever properties.
    Is there something i have missed? Something that needs to be configured before going through that tutorial?
    I run LabView 2011 on a 64 bit Win7P computer. The DSC module and the NI OPC Servers are installed and seem to work (when running the OPC examples ).
    Thanks.

    Hello AmritaNikhil,
    Thanks for the post, I have a few questions for you about this issue.
    What versions of NI OPC Servers are you using?
    Is the server hosted on your local machine or on a remote machine?
    Are you able to successfully connect NI OPC Servers and NI OPC Quick Client?
    Have you been successful in using OPC IO Servers in the past or has this issue occurred since you have started your application?
    Can you consistently reproduce this crash?
    You can try to work around this issue by using Network Items rather than Project Items when creating bound variables in the Create Bound Variables window. Please try this option and let me know if you have any additional information about your application that may be helpful in solving this issue. In addition, I have also included a link to a similar post. Hope this helps!
    LV 2011 crash when create bound variables
    http://forums.ni.com/t5/LabVIEW/LV-2011-crash-when-create-bound-variables/m-p/1879137
    Paul-B
    Applications Engineer
    National Instruments

  • Create test sequence from lab view - add it to the .seq file

    Hello All,
                   I have a query. consider an test sequence that has already stored in "Test.seq" format. let us say we have 5 test steps.
    now is it possible to add a new test step to this existing test sequence using Lab VIEW. I mean if we enter a new test step this has to reflect in the existing test sequence "Test.seq".  i.e in the "Test.seq" we must have 6 test steps.
      If this is possible let me know how this can be done. 

    Michels,
    Guenter mande a very good point.  Make sure to take a look at the forum thread he linked to see the licensing implications of creating your own Sequences.
    There is a very good forum thread that discusses how to create steps programmatically.  You can find the forum here:
    http://forums.ni.com/ni/board/message?board.id=330&message.id=7785&requireLogin=False
    Regards,
    Santiago D

  • Versions of lab view

    Hi:
    Just a few days ago i put this message:
    Hi:
    Im trying, to find a way to search, a file stored in different subfolders of a main folder, and copy, i mean i have a VI which makes a folder everyday (the name istoday date, or yesterday date), and inside that folder is a serial1.txt log file, but yesterday (for axample) the same log file (serial1.txt) was generated, how can i search in lab view all of those serial1.txt files?? By putting just in the search field, the main folder name??? 
    And I want to copy each of these serial1.txt, to different paths???
    So in this days, i ve working and the file is ready, but this archive just search like this: main directory /2nd directory/ 3rd directory/Files.... I mean if the files is deeper in more subdirectorys, does not work well works for me.   
    Im working in lab view 8.5 but, when i tried to put the .exe file in the computers where i have to look for my files, sorprise!!! the computers have the version 7 express or somethig like that so i cant use my file. IT Is possible change the version of my file to version 7?????  
    Solved!
    Go to Solution.
    Attachments:
    search_engine_lol.vi ‏117 KB

    I don't know if you are still asking the same question in this thread or not. If you are, don't start a new thread. 
    As far as the exe, all you have to do is install the 8.5 run-time engine on the other PCs. If you had created an installer (something you should always do), the run-time would have been included.

  • Installation of Lab view 8.20, DAQ Assistant has disappeared & Instrument I/O Assistant cant be used

    After upgrading to Lab view 8.20 and on a 8.20 new install I
    notes’ that
    DAQ Assistant has disappeared from the tool pallet completely.
    Also that Instrument I/O Assistant cant be used or
    configured and produces an error
    “NI Measurement & Automation Explorer or the Instrument
    I/O Assistant is not correctly installed. Please install these from the Driver
    CD”
    I have checked both of these and all parts are fully installed
    and I cant fined what part of the Full version of Labview would course this
    problem.
    Would a completely new installation with default settings
    clear the problem, what has coursed these tools to be not avalible.

    Hi Trevor
    You need to load on the Drivers for DAQmx, if you have a CD you can load them on from there otherwise the link to download NIDAQmx 8.3 is:
    http://digital.ni.com/softlib.nsf/websearch/7feaee6a4b4aa836862571c00064e6ca
    There is a order in which you must load things on for everything to work correctly,
    LabVIEW --->> Modules & Toolkits --->> Drivers
    This should solve your issue
    YatinM
    NIUK

  • Lab view coder wants challange

    Experienced Lab view programmer looking for new challenges in the north of Boston, MA area.  If you are in need of a programmer please contact me.

    hey!!
    Am a university student currently working on a project of 16 qam modem using labview 8.2...dsp kit am using is 6713....Will you be able to help me in this regard....as you are an experienced programmer you must have got some help matrerial for me...
    thanx alot
    wajahat Hassan

  • Lab View is not detecting two com ports of system

    Hi,
       In my PC, three com ports are there COM1, COM4 and COM6. But when we create new visa resource name, lab view is detecting only COM1 port. I want to know is there any way to correct this.
    Regards
    Shivakumar Singh

    Hi,
    First of all check if the ports are visible in the NI MAX. If not, you can try to Create New Port by going into Measuremenmt & Automation Explorer. Assign the Port values accordingly. This can be done by right clicking on the Ports (Serial & Parallel) section of the Devices and Interfaces tree.
    Regards,
    Deepu.

  • Device drive of lab view fpga 2013 for Spartan 3E FPGA

    Hi NI
    I has get labview 2013
    but I need  FPGA device drive of Spartan 3E
    can NI release it for us !!!!!!!!!!!!
    best regards
    hi ?Q>

    T-REX$ wrote:
    Hey mangood,
    There currently is no support for the Spartan3E board in LabVIEW FPGA 2013, and I am not aware of any plan for developing support in the near future. Sorry for the bad news...
    DEAR
    i have lab view 2012 and it has device drvie for spartan FPGA
    only one year
    may be can NI do this its simple
    thank
    hi ?Q>

  • Why does Lab View add control elements to some driver VI's!

    Hi,
    I have downloaded a driver project that was developed with Lab View 2009sp1. Now I will this project use with LV2010.
    To do this I have the library installed in instr.lib. But when I opened some VI's I discovered that Lab View have added control elements.
    Why is it so and how can I stop this behaviour?
    Solved!
    Go to Solution.

    Surely that didnt just happen because you saved it in 2010. You downloaded a new set of drivers for 2010 from here: http://sine.ni.com/apps/utf8/niid_web_display.download_page?p_id_guid=AFAA2CBD85041C96E04400144F1EF8...
    The second driver has more features.
    Also, note that the two modes are different, in the second case you are specifying the current where as the first one is a constant current configuration for the load.
    Beginner? Try LabVIEW Basics
    Sharing bits of code? Try Snippets or LAVA Code Capture Tool
    Have you tried Quick Drop?, Visit QD Community.

Maybe you are looking for

  • Batch operation in function

    hey folks, I have a number of mcs labelled h 1-15. I want to have a function that if someone places an mc on it, it'll lock to the h mc centered. So I'm thinking I'll have a function similar to this (see below). Is there a way to run this without hav

  • How to assign course program block elements to Course Block

    Hi ! I have created a Course Program and added course program blocks but i am not able to add Course Block elements to it. Please guide me how to do this. Is it related to EHP level ? We are at EHP3 level. Anand

  • OOTB Approval workflow and content approval

    I have successfully utilized the OOTB Approval workflow to manage the content approval status for document libraries. But when I attempt the same on a list (custom, links, announcements...etc)..... the approval goes through without a problem but the

  • Broken home screen button

    I have a 4th generation ipod touch, the home button is now sunk in and does not bounce back when I press it. I can not press it at all anymore. This happend from me simply over using it (everyday for atleast 8 hours) and i guess pressin  it too hard.

  • Macbook Air i5 vs i7 fr music recording/production

    Hey all.  I have a 2008 Macbook unibody with a 2.0 GHZ processor.  I want something more current so i'm looking at a MBA.  I mainly want it for music recording/production through Logic and Reason as well as daily internet, photo's and converting the