How to use Enhancement Framework in ECC 5.0 and 6.0

hi
is there any good tutorials on enhancement framework? i have gone through the help but its not very clear. if anyone has stepby step guide will be useful.
~Suresh

This is an old question... but i think it is very useful for the developers if anyone search it and find my answer relevant like it with immediate effect.....
What is Enhancement Framework?????????
Enhancement Framework is the new paradigm to bring all enhancement techniques under one roof. It can also be switched using Switch Framework. The following are different enhancement technologies available under this framework.
• Source Code Enhancement
• Function Group Enhancement
• Class Enhancement
• Kernel-BADI Enhancement
Semantically related enhancement options are grouped under a ‘Simple Enhancement Spot’. ‘Composite Enhancement Spot’ contains one or more of Simple and other Composite Enhancement Spots. On the other hand (implementation side), various related implementation elements are grouped under a ‘Simple Enhancement Implementation’. A ‘Composite Enhancement Implementation’ can contain one or more of Simple and other Complex Enhancement Implementations.
1.Source Code enhancement
Whenever enhancement needs to be incorporated directly into the ABAP source code, this technology shall be provided. Implementing this technology is also called as Source Code Plug-In. There are two types of Source Code enhancements possible.
• Implicit enhancement option
• Explicit enhancement option
>>>Implicit enhancement option
Throughout the ABAP system, enhancement options are automatically available at certain pre-defined places. Some of the implicit options are:
• At the end of all the programs (Includes, Reports, Function pool, Module pool, etc.), after the last statement
• At the beginning and end of all FORM subroutines
• At the end of all Function Modules
• At the end of all visibility areas (public, protected and private) of local class
******Note that, in order to implement any of these Source code enhancements, you need to be in the ‘Change Enhancement mode’ (the spiral icon available in the editor). Technically the source code plug-in implementations are stored in a separate include program and not as part of the original source program.***********
>>>>Explicit enhancement option
The Implicit enhancement options are provided at specific source code places explicitly by SAP (Note that these enhancement definitions can also be created by partners and customers in their code).
There are two types of Explicit Enhancement options available. One which can be provided at a specific place - called Enhancement Point, and another which can be used to replace a set of statements – called Enhancement Section. For this, we now have two new ABAP statements, viz.
• ENHANCEMENT-POINT
• ENHANCEMENT-SECTION
When the Enhancement-Section is implemented, only the implementation gets executed and the original code doesn’t get executed. This is a new technique, which didn’t exist previously in any of the old ways of enhancing, to exclude any standard SAP code from execution. Because of this, there can be only one active implementation of an Enhancement-Section. On the other hand, there can be multiple active implementations of an Enhancement-Point, in which case all the implementations will be executed with no guarantee in the order of execution.
we mainly use above framework .......if nybody need further and more information let me knw...

Similar Messages

  • How to make a view created using enhancement framework as Interface View

    Dear Experts.
    I Created A  new View and window  by using Enhancement Framework for a standard webdynpro comp. Now i want to use the same window as a  UIBB in FPM , since in window properties interface view check box is unchecked it's not allowing me to use a UIBB in FPM.
    Kindly answer for the following.
    1) Is there any way to make a view a interface ( whcih is by default in nature but while creating from Enhancement framework behaivng Strangly).
    2) If there is no way then how to use enhanced (additional View Created  in Standard WDA comp) further like in FPM ( UIBB ).
    thanks in Advance.
    Best Regards,
    Kranthikumar Palle

    >
    kranthi9121 wrote:
    > Dear Experts.
    >
    > I Created A  new View and window  by using Enhancement Framework for a standard webdynpro comp. Now i want to use the same window as a  UIBB in FPM , since in window properties interface view check box is unchecked it's not allowing me to use a UIBB in FPM.
    >
    > Kindly answer for the following.
    >
    > 1) Is there any way to make a view a interface ( whcih is by default in nature but while creating from Enhancement framework behaivng Strangly).
    >
    > 2) If there is no way then how to use enhanced (additional View Created  in Standard WDA comp) further like in FPM ( UIBB ).
    >
    >
    > thanks in Advance.
    >
    > Best Regards,
    > Kranthikumar Palle
    Hi,
    Please see [https://cw.sdn.sap.com/cw/docs/DOC-21546|https://cw.sdn.sap.com/cw/docs/DOC-21546]
    windows created through enhancement are local to component and hence they are not visible outside.
    You need to find other way to provide your interface view to UIBB.

  • How to use Enhancement spot in program

    Hi gurus,
    now i am working ecc 6.0, so how to use Enhancement spot in program, can anybody explain step by step.
    Rewarded with points.
    Thanks
    Naveen

    Hi Naveen ,
    Enhancement Spot are available.
    Examples:
    -End of Executable Program, Include, Function group, Dialog module
    -Begin/End of Form routine / Function module / Method
    -End of a structure
    -End of Private/Protected/Public Section of a local class
    If you want to create Implementation , You have to right click on yellow color line and gve Zxxx and save it in any
    transport request under any dev class. Then you can write your own code and save it and activate it .
    Later If you want to Transport it you need to transport this request.
    Reqward if usefuil
    Thanks
    Jagadeesh.G

  • Any one knows how to use Axis Framework in the SOAP Adapter Modules

    How to use Axis Framework in the SOAP Adapter?
    How to add custom handler modules?
    http://help.sap.com/saphelp_nw04/helpdata/en/45/a4f8bbdfdc0d36e10000000a114a6b/frameset.htm
    I went through the above link on help.sap.com. But still could not create a working example.
    I have created a wc on some 3ed party app server using apaches axis. I am trying to call that web service from XI using SOAP receiver? I need to add some security related headers to the soap message, SO I am trying to use a handler.  I want to know how to configure this handler in SOAP axis adapter module.
    Thank you
    Moni

    Ravi ,
    I am trying exactly the same. Hers is the scenario.
    ABAP Proxy --> PI (7.0) SP 12 ---> WebService.
    Since This is service is secured, means it is using OASIS web servie securyty user name token,
    I am trying to use AXIS adapter. and I want to configure HandlerBean in which I want to use apache wss4j api to add the userNameToken. I am looking for some documentation on this.
    I need to add SOAP action element too as I can not configure this one on the communication channel.
    Thanks for any inputs in this regard.
    Moni

  • How to use enhanced slideshow without .Mac

    (I am Japanese so my English is not good . Sorry)
    I read these iWeb's Discussions and I knew that we can use iWeb's enhanced slideshow without .Mac!
    I read some posts about that , but many links doesn't work and I can't found how to USE.
    So I want source code and, tell me how do I do.
    Please!
    iBook G3 & iMac G5   Mac OS X (10.4.8)   iPod 5G (Black)

    You might be interested in this:
    http://www.codemanic.com/blog-archives/000084.html
    Otherwise, email Cyclosaurus from his web page:
    http://www.geocities.com/[email protected]/

  • How to use multiple VCI strings for lap 1300 and 1200 (option 60) in one pool?

    Hi All,
    Hope to you a very happy new year,
    I have two differnt LAP 1300 and 1200 in my network and I need to add theme to the WLC,
    I successed to add one of theme by the option 60 in the DHCP pool at the Core SW,
    So my quetion is below:
    How to use multiple VCI strings for lap 1300 and 1200 (option 60) in one pool?
    Thanks in Advanced,
    Ahmed,

    To add to Scott's post.  Option 60 would be useful if you needed to put certain types of AP on specific controllers.  Otherwise, no real need to use it for the most part.
    Though, I do recall an issue a few years ago that some windows machines had issues getting DHCP if option 43 is being returned.
    Now, on an IOS switch, you can only configure one option 60 per DHCP scope
    HTH,
    Steve
    Please remember to rate useful posts, and mark questions as answered

  • How to use the admin user account in reports and dashboards?

    Hi Everyone,
    I want to use the admin user account in report and dashboard connections. But the Hyperion is automatically using the current user's credentials to fetch data.
    Hyperion 11.1.1.1
    Thanks
    Syantan

    This has been posted in the essbase forum > How to use the admin user account in reports and dashboards?
    Cheers
    John
    http://john-goodwin.blogspot.com/

  • SSHR reskin AKA 'How to Use Adobe Flash to Transform the Look and Feel...

    There was a presentation at the OHUG 2011 Conference titled 'How to Use Adobe Flash to Transform the Look and Feel of Oracle HR Self Service'. It presented a method of 're-skinning' SSHR to present a different UI to the user.
    Looking for anyone out there that has attempted to apply this to their Oracle HRSS pages. I know this company has developed (is developing?) a product based on this approach. I want to see if anyone has done it on their own and would be willing to share some details.
    Follow-up question. Has anyone availed themselves of the bespoke UI Development based on this approach from Applaud Solutions (as mentioned on their website), and care to comment on your experience?

    Any update on this please? Even we are looking for some pointers in this area.

  • How to use left outer joins ,right outer joins and order by clause for belo

    Hi,
    How to use left outer joins ,right outer joins and order by clause for below XML query.
    The query which is red colour returns null then its not displaying any values for columns in that tables. Tried decode, nvl function hasn't worked.
    SELECT XMLAGG ( XMLELEMENT( "P", XMLFOREST( P.process_id AS Ppid,
              (SELECT XMLAGG( XMLELEMENT( "PI", XMLFOREST( PI.question_id AS PIqid,
                                       PI.process_id AS PIpid,
    PI.innertext AS
                                       PItext, PI.itemtype AS PItype,
                                       PI.linkfrom AS PIfrom,
                                       PI.linkto AS PIto,
    PI.associated AS PIas,
                                       PI.content_id AS PIc,
                                       PI.exitpoint1_id AS PIe1,
                                       PI.exitpoint2_id AS PIe2,
                                       PI.exitpoint3_id AS PIe3,
                                       PI.followoncall AS PIfoc,
    PI.userinput AS PIui,
                                       PI.resolveidentifier AS PIri,
    PI.libquestion_idfk AS PIlqid,
                                       PI.isLocked AS PIstls,
                                       PI.PreviousAnswer AS PIPAns,
                                       PI.VisibleToAgent AS PIVAgent,
                                       PI.RetryAttempt AS PIRetry,
                                       PI.Tags AS PITag,
                                  SELECT XMLAGG( XMLELEMENT( "PO", XMLFOREST( PO.option_id AS POoid,
                                       PO.question_id AS POqid,
                                                           PO.process_id AS popid,
                                                           PO.opt_innertext AS POtext,
                                                           PO.opt_linkfrom AS POfrom,
                                                           PO.opt_linkto AS POto,
                                                           PO.libquestion_idfk AS POlqid,
                                                           PO.liboption_idfk AS POloid ) ) )
                                  FROM vw_liveProcessOption_Sim_v6 PO
                                       WHERE PI.question_id = PO.question_id (+)
                                  AND PI.process_id = PO.process_id (+)
                                  ) "A" ) ) ) AS "PO"
         FROM vw_liveProcessItem_Sim_v6 PI
              WHERE P.process_id = PI.process_id
              ) "A" ) ) ) AS "PI"
    FROM liveProcess_ec P
    WHERE (P.process_id = 450)
    Any help really appreciated.
    Thanks

    user512743 wrote:
    Hi,
    Here below is the scripts of tables, insert statements and Required output.
    CREATE TABLE VW_LIVEPROCESSOPTION_SIM_v6
    (     "OPTION_ID" NUMBER,
         "QUESTION_ID" NUMBER(10,0),
         "PROCESS_ID" NUMBER(10,0),
         "OPT_INNERTEXT" VARCHAR2(200 CHAR),
         "OPT_LINKFROM" VARCHAR2(20 CHAR),
         "OPT_LINKTO" VARCHAR2(20 CHAR),
         "LIBQUESTION_IDFK" NUMBER,
         "LIBOPTION_IDFK" NUMBER
    Insert into VW_LIVEPROCESSOPTION_SIM_v6(OPTION_ID,QUESTION_ID,PROCESS_ID,OPT_INNERTEXT,OPT_LINKFROM,OPT_LINKTO,LIBQUESTION_IDFK,LIBOPTION_IDFK) values (1,2,450,'Yes',null,'5',null,null);
    Insert into VW_LIVEPROCESSOPTION_SIM_v6(OPTION_ID,QUESTION_ID,PROCESS_ID,OPT_INNERTEXT,OPT_LINKFROM,OPT_LINKTO,LIBQUESTION_IDFK,LIBOPTION_IDFK) values (1,3,450,'Yes',null,'5',null,null);
    Insert into VW_LIVEPROCESSOPTION_SIM_v6(OPTION_ID,QUESTION_ID,PROCESS_ID,OPT_INNERTEXT,OPT_LINKFROM,OPT_LINKTO,LIBQUESTION_IDFK,LIBOPTION_IDFK) values (1,5,450,'Yes',null,'6',null,null);
    Insert into VW_LIVEPROCESSOPTION_SIM_v6(OPTION_ID,QUESTION_ID,PROCESS_ID,OPT_INNERTEXT,OPT_LINKFROM,OPT_LINKTO,LIBQUESTION_IDFK,LIBOPTION_IDFK) values (1,6,450,'Yes',null,'7',null,null);
    Insert into VW_LIVEPROCESSOPTION_SIM_v6(OPTION_ID,QUESTION_ID,PROCESS_ID,OPT_INNERTEXT,OPT_LINKFROM,OPT_LINKTO,LIBQUESTION_IDFK,LIBOPTION_IDFK) values (1,8,450,'Block All',null,'9',null,null);
    Insert into VW_LIVEPROCESSOPTION_SIM_v6(OPTION_ID,QUESTION_ID,PROCESS_ID,OPT_INNERTEXT,OPT_LINKFROM,OPT_LINKTO,LIBQUESTION_IDFK,LIBOPTION_IDFK) values (1,9,450,'Yes',null,'10',null,null);
    Insert into VW_LIVEPROCESSOPTION_SIM_v6(OPTION_ID,QUESTION_ID,PROCESS_ID,OPT_INNERTEXT,OPT_LINKFROM,OPT_LINKTO,LIBQUESTION_IDFK,LIBOPTION_IDFK) values (1,11,450,'Yes',null,'12',null,null);
    Insert into VW_LIVEPROCESSOPTION_SIM_v6(OPTION_ID,QUESTION_ID,PROCESS_ID,OPT_INNERTEXT,OPT_LINKFROM,OPT_LINKTO,LIBQUESTION_IDFK,LIBOPTION_IDFK) values (1,12,450,'Yes',null,'13',null,null);
    Insert into VW_LIVEPROCESSOPTION_SIM_v6(OPTION_ID,QUESTION_ID,PROCESS_ID,OPT_INNERTEXT,OPT_LINKFROM,OPT_LINKTO,LIBQUESTION_IDFK,LIBOPTION_IDFK) values (1,14,450,'Yes',null,'16',null,null);
    Insert into VW_LIVEPROCESSOPTION_SIM_v6(OPTION_ID,QUESTION_ID,PROCESS_ID,OPT_INNERTEXT,OPT_LINKFROM,OPT_LINKTO,LIBQUESTION_IDFK,LIBOPTION_IDFK) values (2,2,450,'No',null,'3',null,null);
    Insert into VW_LIVEPROCESSOPTION_SIM_v6(OPTION_ID,QUESTION_ID,PROCESS_ID,OPT_INNERTEXT,OPT_LINKFROM,OPT_LINKTO,LIBQUESTION_IDFK,LIBOPTION_IDFK) values (2,3,450,'No',null,'4',null,null);
    Insert into VW_LIVEPROCESSOPTION_SIM_v6(OPTION_ID,QUESTION_ID,PROCESS_ID,OPT_INNERTEXT,OPT_LINKFROM,OPT_LINKTO,LIBQUESTION_IDFK,LIBOPTION_IDFK) values (2,5,450,'No',null,'8',null,null);
    Insert into VW_LIVEPROCESSOPTION_SIM_v6(OPTION_ID,QUESTION_ID,PROCESS_ID,OPT_INNERTEXT,OPT_LINKFROM,OPT_LINKTO,LIBQUESTION_IDFK,LIBOPTION_IDFK) values (2,6,450,'No',null,'8',null,null);
    Insert into VW_LIVEPROCESSOPTION_SIM_v6(OPTION_ID,QUESTION_ID,PROCESS_ID,OPT_INNERTEXT,OPT_LINKFROM,OPT_LINKTO,LIBQUESTION_IDFK,LIBOPTION_IDFK) values (2,8,450,'Standard',null,'11',null,null);
    Insert into VW_LIVEPROCESSOPTION_SIM_v6(OPTION_ID,QUESTION_ID,PROCESS_ID,OPT_INNERTEXT,OPT_LINKFROM,OPT_LINKTO,LIBQUESTION_IDFK,LIBOPTION_IDFK) values (2,9,450,'No',null,'11',null,null);
    Insert into VW_LIVEPROCESSOPTION_SIM_v6(OPTION_ID,QUESTION_ID,PROCESS_ID,OPT_INNERTEXT,OPT_LINKFROM,OPT_LINKTO,LIBQUESTION_IDFK,LIBOPTION_IDFK) values (2,11,450,'No',null,'14',null,null);
    Insert into VW_LIVEPROCESSOPTION_SIM_v6(OPTION_ID,QUESTION_ID,PROCESS_ID,OPT_INNERTEXT,OPT_LINKFROM,OPT_LINKTO,LIBQUESTION_IDFK,LIBOPTION_IDFK) values (2,12,450,'No',null,'14',null,null);
    Insert into VW_LIVEPROCESSOPTION_SIM_v6(OPTION_ID,QUESTION_ID,PROCESS_ID,OPT_INNERTEXT,OPT_LINKFROM,OPT_LINKTO,LIBQUESTION_IDFK,LIBOPTION_IDFK) values (2,14,450,'No',null,'15',null,null);
    Insert into VW_LIVEPROCESSOPTION_SIM_v6(OPTION_ID,QUESTION_ID,PROCESS_ID,OPT_INNERTEXT,OPT_LINKFROM,OPT_LINKTO,LIBQUESTION_IDFK,LIBOPTION_IDFK) values (3,8,450,'Disabled',null,'12',null,null);
    Insert into VW_LIVEPROCESSOPTION_SIM_v6(OPTION_ID,QUESTION_ID,PROCESS_ID,OPT_INNERTEXT,OPT_LINKFROM,OPT_LINKTO,LIBQUESTION_IDFK,LIBOPTION_IDFK) values (4,8,450,'User Defined',null,'12',null,null);
    REATE TABLE "VW_LIVEPROCESSITEM_SIM_v6"
    (     "QUESTION_ID" NUMBER(10,0),
         "PROCESS_ID" NUMBER(10,0),
         "INNERTEXT" VARCHAR2(200 CHAR),
         "ITEMTYPE" VARCHAR2(50 CHAR),
         "LINKFROM" VARCHAR2(500 CHAR),
         "LINKTO" VARCHAR2(500 CHAR),
         "ASSOCIATED" VARCHAR2(200 CHAR),
         "CONTENT_ID" NUMBER,
         "EXITPOINT1_ID" NUMBER(10,0),
         "EXITPOINT2_ID" NUMBER(10,0),
         "EXITPOINT3_ID" NUMBER(10,0),
         "RESOLVEIDENTIFIER" VARCHAR2(40 CHAR),
         "LIBQUESTION_IDFK" NUMBER(10,0),
         "FOLLOWONCALL" NUMBER(1,0),
         "USERINPUT" VARCHAR2(200 CHAR),
         "ISLOCKED" NUMBER(1,0),
         "PREVIOUSANSWER" NUMBER(1,0),
         "VISIBLETOAGENT" NUMBER(1,0),
         "RETRYATTEMPT" NUMBER(10,0),
         "TAGS" VARCHAR2(50 BYTE)
    Insert into VW_LIVEPROCESSITEM_SIM_v6 (QUESTION_ID,PROCESS_ID,INNERTEXT,ITEMTYPE,LINKFROM,LINKTO,ASSOCIATED,CONTENT_ID,EXITPOINT1_ID,EXITPOINT2_ID,EXITPOINT3_ID,RESOLVEIDENTIFIER,LIBQUESTION_IDFK,FOLLOWONCALL,USERINPUT,ISLOCKED,PREVIOUSANSWER,VISIBLETOAGENT,RETRYATTEMPT,TAGS) values (1,450,'CBB1015 - Router Firewall Settinngs Process','Title',null,'2',null,null,null,null,null,null,null,null,null,null,null,null,null,null);
    Insert into VW_LIVEPROCESSITEM_SIM_v6 (QUESTION_ID,PROCESS_ID,INNERTEXT,ITEMTYPE,LINKFROM,LINKTO,ASSOCIATED,CONTENT_ID,EXITPOINT1_ID,EXITPOINT2_ID,EXITPOINT3_ID,RESOLVEIDENTIFIER,LIBQUESTION_IDFK,FOLLOWONCALL,USERINPUT,ISLOCKED,PREVIOUSANSWER,VISIBLETOAGENT,RETRYATTEMPT,TAGS) values (2,450,'Is the customers PC Firewall turned off?','Question','1','2.2,2.1',null,null,null,null,null,null,null,null,null,null,null,null,null,null);
    Insert into VW_LIVEPROCESSITEM_SIM_v6 (QUESTION_ID,PROCESS_ID,INNERTEXT,ITEMTYPE,LINKFROM,LINKTO,ASSOCIATED,CONTENT_ID,EXITPOINT1_ID,EXITPOINT2_ID,EXITPOINT3_ID,RESOLVEIDENTIFIER,LIBQUESTION_IDFK,FOLLOWONCALL,USERINPUT,ISLOCKED,PREVIOUSANSWER,VISIBLETOAGENT,RETRYATTEMPT,TAGS) values (3,450,'Advise the customer to turn off the PC Firewall in order to continue. Has this been done?','Question','2.2','3.2,3.1',null,278,null,null,null,null,null,null,null,null,null,null,null,null);
    Insert into VW_LIVEPROCESSITEM_SIM_v6 (QUESTION_ID,PROCESS_ID,INNERTEXT,ITEMTYPE,LINKFROM,LINKTO,ASSOCIATED,CONTENT_ID,EXITPOINT1_ID,EXITPOINT2_ID,EXITPOINT3_ID,RESOLVEIDENTIFIER,LIBQUESTION_IDFK,FOLLOWONCALL,USERINPUT,ISLOCKED,PREVIOUSANSWER,VISIBLETOAGENT,RETRYATTEMPT,TAGS) values (4,450,'Advise the customer the PC Firewall must be switched off before this process????','ExitPoint','3.2',null,null,null,14,null,null,null,null,null,null,null,null,null,null,null);
    Insert into VW_LIVEPROCESSITEM_SIM_v6 (QUESTION_ID,PROCESS_ID,INNERTEXT,ITEMTYPE,LINKFROM,LINKTO,ASSOCIATED,CONTENT_ID,EXITPOINT1_ID,EXITPOINT2_ID,EXITPOINT3_ID,RESOLVEIDENTIFIER,LIBQUESTION_IDFK,FOLLOWONCALL,USERINPUT,ISLOCKED,PREVIOUSANSWER,VISIBLETOAGENT,RETRYATTEMPT,TAGS) values (5,450,'Is the customer able to access the internet now?','Question','3.1,2.1','5.2,5.1',null,null,null,null,null,null,null,null,null,null,null,null,null,null);
    Insert into VW_LIVEPROCESSITEM_SIM_v6 (QUESTION_ID,PROCESS_ID,INNERTEXT,ITEMTYPE,LINKFROM,LINKTO,ASSOCIATED,CONTENT_ID,EXITPOINT1_ID,EXITPOINT2_ID,EXITPOINT3_ID,RESOLVEIDENTIFIER,LIBQUESTION_IDFK,FOLLOWONCALL,USERINPUT,ISLOCKED,PREVIOUSANSWER,VISIBLETOAGENT,RETRYATTEMPT,TAGS) values (6,450,'Is the customer having a problem with a specific website?','Question','5.1','6.2,6.1',null,null,null,null,null,null,null,null,null,null,null,null,null,null);
    Insert into VW_LIVEPROCESSITEM_SIM_v6 (QUESTION_ID,PROCESS_ID,INNERTEXT,ITEMTYPE,LINKFROM,LINKTO,ASSOCIATED,CONTENT_ID,EXITPOINT1_ID,EXITPOINT2_ID,EXITPOINT3_ID,RESOLVEIDENTIFIER,LIBQUESTION_IDFK,FOLLOWONCALL,USERINPUT,ISLOCKED,PREVIOUSANSWER,VISIBLETOAGENT,RETRYATTEMPT,TAGS) values (7,450,'1536: CBB1008 - Browser Setup and Daignostics','SubProcess','6.1',null,'1536-1-0',null,null,null,null,null,null,null,null,null,null,null,null,null);
    Insert into VW_LIVEPROCESSITEM_SIM_v6 (QUESTION_ID,PROCESS_ID,INNERTEXT,ITEMTYPE,LINKFROM,LINKTO,ASSOCIATED,CONTENT_ID,EXITPOINT1_ID,EXITPOINT2_ID,EXITPOINT3_ID,RESOLVEIDENTIFIER,LIBQUESTION_IDFK,FOLLOWONCALL,USERINPUT,ISLOCKED,PREVIOUSANSWER,VISIBLETOAGENT,RETRYATTEMPT,TAGS) values (8,450,'What is the security level on the CPE Management page?','Question','6.2,5.2','8.4,8.3,8.2,8.1',null,279,null,null,null,null,null,null,null,null,null,null,null,null);
    Insert into VW_LIVEPROCESSITEM_SIM_v6 (QUESTION_ID,PROCESS_ID,INNERTEXT,ITEMTYPE,LINKFROM,LINKTO,ASSOCIATED,CONTENT_ID,EXITPOINT1_ID,EXITPOINT2_ID,EXITPOINT3_ID,RESOLVEIDENTIFIER,LIBQUESTION_IDFK,FOLLOWONCALL,USERINPUT,ISLOCKED,PREVIOUSANSWER,VISIBLETOAGENT,RETRYATTEMPT,TAGS) values (9,450,'Change the security level to Standard. Does this resolve the customers issue?','Question','8.1','9.2,9.1',null,280,null,null,null,null,null,null,null,null,null,null,null,null);
    Insert into VW_LIVEPROCESSITEM_SIM_v6 (QUESTION_ID,PROCESS_ID,INNERTEXT,ITEMTYPE,LINKFROM,LINKTO,ASSOCIATED,CONTENT_ID,EXITPOINT1_ID,EXITPOINT2_ID,EXITPOINT3_ID,RESOLVEIDENTIFIER,LIBQUESTION_IDFK,FOLLOWONCALL,USERINPUT,ISLOCKED,PREVIOUSANSWER,VISIBLETOAGENT,RETRYATTEMPT,TAGS) values (10,450,'Issue Resolved','ExitPoint','9.1',null,null,null,1,6,122,null,null,null,null,null,null,null,null,null);
    Insert into VW_LIVEPROCESSITEM_SIM_v6 (QUESTION_ID,PROCESS_ID,INNERTEXT,ITEMTYPE,LINKFROM,LINKTO,ASSOCIATED,CONTENT_ID,EXITPOINT1_ID,EXITPOINT2_ID,EXITPOINT3_ID,RESOLVEIDENTIFIER,LIBQUESTION_IDFK,FOLLOWONCALL,USERINPUT,ISLOCKED,PREVIOUSANSWER,VISIBLETOAGENT,RETRYATTEMPT,TAGS) values (11,450,'Change the security level to Disabled. Is the customer able to browse the internet?','Question','9.2,8.2','11.2,11.1',null,281,null,null,null,null,null,null,null,null,null,null,null,null);
    Insert into VW_LIVEPROCESSITEM_SIM_v6 (QUESTION_ID,PROCESS_ID,INNERTEXT,ITEMTYPE,LINKFROM,LINKTO,ASSOCIATED,CONTENT_ID,EXITPOINT1_ID,EXITPOINT2_ID,EXITPOINT3_ID,RESOLVEIDENTIFIER,LIBQUESTION_IDFK,FOLLOWONCALL,USERINPUT,ISLOCKED,PREVIOUSANSWER,VISIBLETOAGENT,RETRYATTEMPT,TAGS) values (12,450,'Change the security level to Standard. Is the customer able to browse the internet now?','Question','11.1,8.3,8.4','12.2,12.1',null,283,null,null,null,null,null,null,null,null,null,null,null,null);
    Insert into VW_LIVEPROCESSITEM_SIM_v6 (QUESTION_ID,PROCESS_ID,INNERTEXT,ITEMTYPE,LINKFROM,LINKTO,ASSOCIATED,CONTENT_ID,EXITPOINT1_ID,EXITPOINT2_ID,EXITPOINT3_ID,RESOLVEIDENTIFIER,LIBQUESTION_IDFK,FOLLOWONCALL,USERINPUT,ISLOCKED,PREVIOUSANSWER,VISIBLETOAGENT,RETRYATTEMPT,TAGS) values (13,450,'Issue Resolved','ExitPoint','12.1',null,null,null,1,6,123,null,null,null,null,null,null,null,null,null);
    Insert into VW_LIVEPROCESSITEM_SIM_v6 (QUESTION_ID,PROCESS_ID,INNERTEXT,ITEMTYPE,LINKFROM,LINKTO,ASSOCIATED,CONTENT_ID,EXITPOINT1_ID,EXITPOINT2_ID,EXITPOINT3_ID,RESOLVEIDENTIFIER,LIBQUESTION_IDFK,FOLLOWONCALL,USERINPUT,ISLOCKED,PREVIOUSANSWER,VISIBLETOAGENT,RETRYATTEMPT,TAGS) values (14,450,'Ask the customer to perform a master reset. Does this resolve their issue?','Question','12.2,11.2','14.2,14.1',null,282,null,null,null,null,null,null,null,null,null,null,null,null);
    Insert into VW_LIVEPROCESSITEM_SIM_v6 (QUESTION_ID,PROCESS_ID,INNERTEXT,ITEMTYPE,LINKFROM,LINKTO,ASSOCIATED,CONTENT_ID,EXITPOINT1_ID,EXITPOINT2_ID,EXITPOINT3_ID,RESOLVEIDENTIFIER,LIBQUESTION_IDFK,FOLLOWONCALL,USERINPUT,ISLOCKED,PREVIOUSANSWER,VISIBLETOAGENT,RETRYATTEMPT,TAGS) values (15,450,'Faulty CPE','ExitPoint','14.2',null,null,null,1,6,124,null,null,null,null,null,null,null,null,null);
    Insert into VW_LIVEPROCESSITEM_SIM_v6 (QUESTION_ID,PROCESS_ID,INNERTEXT,ITEMTYPE,LINKFROM,LINKTO,ASSOCIATED,CONTENT_ID,EXITPOINT1_ID,EXITPOINT2_ID,EXITPOINT3_ID,RESOLVEIDENTIFIER,LIBQUESTION_IDFK,FOLLOWONCALL,USERINPUT,ISLOCKED,PREVIOUSANSWER,VISIBLETOAGENT,RETRYATTEMPT,TAGS) values (16,450,'Issue Resolved','ExitPoint','14.1',null,null,null,1,6,123,null,null,null,null,null,null,null,null,null);
    CREATE TABLE "LIVEPROCESS_EC_V"
    (     "PROCESS_ID" NUMBER(10,0),
         "USER_ID" NUMBER(10,0),
         "CREATED" TIMESTAMP (6)
    Insert into LIVEPROCESS_EC (PROCESS_ID,USER_ID,CREATED) values (450,7460,to_timestamp('21-APR-08 09.34.41.000000000 AM','DD-MON-RR HH.MI.SS.FF AM'));
    Required O/P in XML format
    <P>
    <Ppid>450</Ppid>
    <PI>
    <PIqid>1</PIqid>
    <PIpid>450</PIpid>
    <PItext>CBB1015 - Router Firewall Settinngs Process</PItext>
    <PItype>Title</PItype>
    <PIto>2</PIto>
    <PO />
    </PI>
    <PI>
    <PIqid>2</PIqid>
    <PIpid>450</PIpid>
    <PItext>Is the customers PC Firewall turned off?</PItext>
    <PItype>Question</PItype>
    <PIfrom>1</PIfrom>
    <PIto>2.2,2.1</PIto>
    <PO>
    <POoid>1</POoid>
    <POqid>2</POqid>
    <popid>450</popid>
    <POtext>Yes</POtext>
    <POto>5</POto>
    </PO>
    <PO>
    <POoid>2</POoid>
    <POqid>2</POqid>
    <popid>450</popid>
    <POtext>No</POtext>
    <POto>3</POto>
    </PO>
    </PI>
    <PI>
    <PIqid>3</PIqid>
    <PIpid>450</PIpid>
    <PItext>Advise the customer to turn off the PC Firewall in order to continue. Has this been done?</PItext>
    <PItype>Question</PItype>
    <PIfrom>2.2</PIfrom>
    <PIto>3.2,3.1</PIto>
    <PIc>278</PIc>
    <PO>
    <POoid>1</POoid>
    <POqid>3</POqid>
    <popid>450</popid>
    <POtext>Yes</POtext>
    <POto>5</POto>
    </PO>
    <PO>
    <POoid>2</POoid>
    <POqid>3</POqid>
    <popid>450</popid>
    <POtext>No</POtext>
    <POto>4</POto>
    </PO>
    </PI>
    <PI>
    <PIqid>4</PIqid>
    <PIpid>450</PIpid>
    <PItext>Advise the customer the PC Firewall must be switched off before this process????</PItext>
    <PItype>ExitPoint</PItype>
    <PIfrom>3.2</PIfrom>
    <PIe1>14</PIe1>
    <PO />
    </PI>
    <PI>
    <PIqid>5</PIqid>
    <PIpid>450</PIpid>
    <PItext>Is the customer able to access the internet now?</PItext>
    <PItype>Question</PItype>
    <PIfrom>3.1,2.1</PIfrom>
    <PIto>5.2,5.1</PIto>
    <PO>
    <POoid>1</POoid>
    <POqid>5</POqid>
    <popid>450</popid>
    <POtext>Yes</POtext>
    <POto>6</POto>
    </PO>
    <PO>
    <POoid>2</POoid>
    <POqid>5</POqid>
    <popid>450</popid>
    <POtext>No</POtext>
    <POto>8</POto>
    </PO>
    </PI>
    <PI>
    <PIqid>6</PIqid>
    <PIpid>450</PIpid>
    <PItext>Is the customer having a problem with a specific website?</PItext>
    <PItype>Question</PItype>
    <PIfrom>5.1</PIfrom>
    <PIto>6.2,6.1</PIto>
    <PO>
    <POoid>1</POoid>
    <POqid>6</POqid>
    <popid>450</popid>
    <POtext>Yes</POtext>
    <POto>7</POto>
    </PO>
    <PO>
    <POoid>2</POoid>
    <POqid>6</POqid>
    <popid>450</popid>
    <POtext>No</POtext>
    <POto>8</POto>
    </PO>
    </PI>
    <PI>
    <PIqid>7</PIqid>
    <PIpid>450</PIpid>
    <PItext>1536: CBB1008 - Browser Setup and Daignostics</PItext>
    <PItype>SubProcess</PItype>
    <PIfrom>6.1</PIfrom>
    <PIas>1536-1-0</PIas>
    <PO />
    </PI>
    <PI>
    <PIqid>8</PIqid>
    <PIpid>450</PIpid>
    <PItext>What is the security level on the CPE Management page?</PItext>
    <PItype>Question</PItype>
    <PIfrom>6.2,5.2</PIfrom>
    <PIto>8.4,8.3,8.2,8.1</PIto>
    <PIc>279</PIc>
    <PO>
    <POoid>1</POoid>
    <POqid>8</POqid>
    <popid>450</popid>
    <POtext>Block All</POtext>
    <POto>9</POto>
    </PO>
    <PO>
    <POoid>2</POoid>
    <POqid>8</POqid>
    <popid>450</popid>
    <POtext>Standard</POtext>
    <POto>11</POto>
    </PO>
    <PO>
    <POoid>3</POoid>
    <POqid>8</POqid>
    <popid>450</popid>
    <POtext>Disabled</POtext>
    <POto>12</POto>
    </PO>
    <PO>
    <POoid>4</POoid>
    <POqid>8</POqid>
    <popid>450</popid>
    <POtext>User Defined</POtext>
    <POto>12</POto>
    </PO>
    </PI>
    <PI>
    <PIqid>9</PIqid>
    <PIpid>450</PIpid>
    <PItext>Change the security level to Standard. Does this resolve the customers issue?</PItext>
    <PItype>Question</PItype>
    <PIfrom>8.1</PIfrom>
    <PIto>9.2,9.1</PIto>
    <PIc>280</PIc>
    <PO>
    <POoid>1</POoid>
    <POqid>9</POqid>
    <popid>450</popid>
    <POtext>Yes</POtext>
    <POto>10</POto>
    </PO>
    <PO>
    <POoid>2</POoid>
    <POqid>9</POqid>
    <popid>450</popid>
    <POtext>No</POtext>
    <POto>11</POto>
    </PO>
    </PI>
    <PI>
    <PIqid>10</PIqid>
    <PIpid>450</PIpid>
    <PItext>Issue Resolved</PItext>
    <PItype>ExitPoint</PItype>
    <PIfrom>9.1</PIfrom>
    <PIe1>1</PIe1>
    <PIe2>6</PIe2>
    <PIe3>122</PIe3>
    <PO />
    </PI>
    <PI>
    <PIqid>11</PIqid>
    <PIpid>450</PIpid>
    <PItext>Change the security level to Disabled. Is the customer able to browse the internet?</PItext>
    <PItype>Question</PItype>
    <PIfrom>9.2,8.2</PIfrom>
    <PIto>11.2,11.1</PIto>
    <PIc>281</PIc>
    <PO>
    <POoid>1</POoid>
    <POqid>11</POqid>
    <popid>450</popid>
    <POtext>Yes</POtext>
    <POto>12</POto>
    </PO>
    <PO>
    <POoid>2</POoid>
    <POqid>11</POqid>
    <popid>450</popid>
    <POtext>No</POtext>
    <POto>14</POto>
    </PO>
    </PI>
    <PI>
    <PIqid>12</PIqid>
    <PIpid>450</PIpid>
    <PItext>Change the security level to Standard. Is the customer able to browse the internet now?</PItext>
    <PItype>Question</PItype>
    <PIfrom>11.1,8.3,8.4</PIfrom>
    <PIto>12.2,12.1</PIto>
    <PIc>283</PIc>
    <PO>
    <POoid>1</POoid>
    <POqid>12</POqid>
    <popid>450</popid>
    <POtext>Yes</POtext>
    <POto>13</POto>
    </PO>
    <PO>
    <POoid>2</POoid>
    <POqid>12</POqid>
    <popid>450</popid>
    <POtext>No</POtext>
    <POto>14</POto>
    </PO>
    </PI>
    <PI>
    <PIqid>13</PIqid>
    <PIpid>450</PIpid>
    <PItext>Issue Resolved</PItext>
    <PItype>ExitPoint</PItype>
    <PIfrom>12.1</PIfrom>
    <PIe1>1</PIe1>
    <PIe2>6</PIe2>
    <PIe3>123</PIe3>
    <PO />
    </PI>
    <PI>
    <PIqid>14</PIqid>
    <PIpid>450</PIpid>
    <PItext>Ask the customer to perform a master reset. Does this resolve their issue?</PItext>
    <PItype>Question</PItype>
    <PIfrom>12.2,11.2</PIfrom>
    <PIto>14.2,14.1</PIto>
    <PIc>282</PIc>
    <PO>
    <POoid>1</POoid>
    <POqid>14</POqid>
    <popid>450</popid>
    <POtext>Yes</POtext>
    <POto>16</POto>
    </PO>
    <PO>
    <POoid>2</POoid>
    <POqid>14</POqid>
    <popid>450</popid>
    <POtext>No</POtext>
    <POto>15</POto>
    </PO>
    </PI>
    <PI>
    <PIqid>15</PIqid>
    <PIpid>450</PIpid>
    <PItext>Faulty CPE</PItext>
    <PItype>ExitPoint</PItype>
    <PIfrom>14.2</PIfrom>
    <PIe1>1</PIe1>
    <PIe2>6</PIe2>
    <PIe3>124</PIe3>
    <PO />
    </PI>
    <PI>
    <PIqid>16</PIqid>
    <PIpid>450</PIpid>
    <PItext>Issue Resolved</PItext>
    <PItype>ExitPoint</PItype>
    <PIfrom>14.1</PIfrom>
    <PIe1>1</PIe1>
    <PIe2>6</PIe2>
    <PIe3>123</PIe3>
    <PO />
    </PI>
    </P>
    Thanks in advance
    Edited by: user512743 on Nov 18, 2008 4:46 AM

  • I had nokia n8 and now i want to transfer my contacts from nokia to my new i phone 5, i set up i tune and i cloud account but i don't know how to use do it. i have windows 7 and no outlook

    i had nokia n8 and now i want to transfer my contacts from nokia to my new i phone 5, i set up i tune and i cloud account but i don't know how to use do it. i have windows 7 and no outlook

    If I wiped my phone I wouldn't have the contacts on my phone to send to my self.    I would need to take just the contacts from my back up. I would have to do this through iTunes and I don't see how I can just extract the contacts only from my back up. From what I can figure out it is all or nothing

  • How to use WMI to query to distinguish legacy and UEFI mode Windows?

    How to use WMI to query to distinguish legacy and UEFI mode Windows?

    This document covers requirements for UEFI support.
    http://msdn.microsoft.com/en-us/windows/hardware/gg463144.aspx
    One of the requirements seems to be ACPI. The Win32_BIOS class of WMI has a BIOSCharacteristics property that indicates if ACPI is supported. See this link for properties exposed by Win32_BIOS:
    http://msdn.microsoft.com/en-us/library/aa394077(v=VS.85).aspx
    There is a PowerShell example showing how to get this information at the bottom. You will need to study the document in the first link to see what else is required.
    Richard Mueller - MVP Directory Services

  • Enhancement framework in ECC 6.0

    I have some question regarding ECC6.0 version:-
    1) what is enhancement framework.
    2) HOW IT IS BETTER THAN USER EXITS AND BADI?
    3) And one more after creating a ztable in ecc6.0  , do we have to do enhancement? what is it , not getting this pint... can u pls clarify my doubt....
    Pls do reply to my queries.....
    Thanks
    ankita

    Thanks you very much...very helpful answer.
    One thing do you have any doc or notes in regards to the table/ structure enhancement category in ECC6.0.
    Pls do send if you have.
    And the link regarding Enhacement framework is also very helpful to understand.
    Thanks once again:))

  • How to use web service in ECC 6.0

    Hi.
    I found some WSDL in "SDN ES Workplace".
    Anybody know how to use this WSDL ?
    For example, I want to use 'Query Sales Order' web service and I found WSDL in "SDN ES Workplace".
    What's next step to use this web service ?
    Regards, Arnold.

    Hi Austin,
    Link provided for mySAP ERP Enterprise Service Package ECC-SE 600, does not work. My company is SAP customer and I am SDN member.
    Do I need some special login or membership to download ES packages?
    I also understand that I can access the Enterprise Service from the ES Workplace (implementation) and for that I have to Apply For an Account. I applied for an account at this link https://www.sdn.sap.com/irj/sdn/esareg .
    After applying for an Account should be getting an email with user Id/password OR I can use the my Service Market Place ID?
    Tried entering the my service market place Id, does not work.
    Thanks,
    Abhay

  • Can anyone tell me how to use Tiles framework in an existing JSP page

    I want to seperate my portal area using tiles. I'm looking for example on how I go about that.

    This book doesn't have information on how to use tiles in legacy JSP page. Let me rephase the question again:
    How do I place Tiles tags to an existing JSP page to seperate the areas in a page?

  • How to use cairngorm framework in flex 4?

    Hi Everyone!
    Right now i am working with Flex 3.5 sdk using cairgorm architecture. Now i want to move to Flex 4 sdk with cairgorm architecture. I tried to use the cairngorm architecture in flex 4 sdk. But i did not get the output.
         Please anyone let me know how to use the cairngorm artchitecture in flex 4 sdk.
    Thanks in advance.!

    Read about Presentation Model. Refactor towards that and you should fine.
    C

Maybe you are looking for

  • Exporting as a PDF with missing fonts - help please?

    Hi, I am using Windows In Design CS4 and an agency provided us with a template via Mac OSX. Some of the fonts they used appear to be missing on Windows (mainly the ITC bookman family), I open the file anyway. When I export it to a PDF the PDF appears

  • Only one headphone works

    please help me to figure out what can I do to restablish function of the 2 headphone thank you

  • I deleted the podcast folder from my ipod. How do I get it back?

    How do I recreate the podcast folder on my ipod nit in itunes. I stil have the podcast folder in itunes.

  • Transporting table changes

    Hi folks, I've made changes to a custom table in SE11(including keys and add new fields). Question is, if these changes are being transported to QA system, will the current table in QA system will be overwritten? how about the current content of tabl

  • MAPI issue between Outlook 2007 and third party software