Hello ,
I want to know if any1 can help me with this issue of writing Protocol Drivers to establish a PPP communication .
Using Labview 8 version.If any of you ll know anything regarding PPP communication do send me link or attachment
Waiting in anticipation.
Regards.
yogan
The PPP standard is defined in (IETF) RFC 1661. An overview of the PPP protocol is available on wikipedia.
PPP is a data link layer protocol. Writing a PPP implimentation in LabVIEW is going to be a significant effort. LabVIEW generally passes this level of communications to the OS.
Message Edited by Phillip Brooks on 01-16-2008 07:05 AM
Now is the right time to use %^<%Y-%m-%dT%H:%M:%S%3uZ>T
If you don't hate time zones, you're not a real programmer.
"You are what you don't automate"
Inplaceness is synonymous with insidiousness
Similar Messages
-
Write PPP protocol driver to establish PPP communication
Dear Sir,
As there is no PPP specific functions in LabVIEW ......
I want to know more about how to write PPP protocol drivers, in register level programming, for labview version 8.
As i want to establish PPP communication over RS-232 to send & recieve data from GUI created in LabVIEW to a third party device ...
how to do register level programing in Labview ? ...
& to do register level programing do I need to have any additional interfacing software installed?
If you have any reference or any sample code relating to my query , do mail me the link..
Waiting in anticipation.
Regards .
YoganYogan,
Welcome to the discussion forums. Since there are no PPP specific functions inside of LabVIEW, have you considered using NI-VISA instead? VISA has VIs that have the ability to control at the registry level. Here are some additional resources that further expound upon VISA and its capabilities.
NI-VISA Overview
Serial Instrument Control Tutorial
VISA VIs and Functions
VISA Advanced VIs and Functions
Drivers and Updates: NI-VISA
A_Ryan
AES
National Instruments -
How to write a driver for custom hardware on a digital port
Hi,
I am a complete newbie to LabView and so I hope that someone can hint me to the information I need.
At the moment, I am completely lost.
I have the CVS-1454 which has a digital I/O port.
Now I want to plug a custom made converter on this port to convert the digital port into 4 RS232 ports.
The hardware is not the problem, but how do I write a driver for my box?
Is there some kind of tutorial on writing drivers available?
All I found in the official documentation was that you can write your own drivers, but the link to the page which should give more information was invalid :-(
Thank you for reading and have a nice day,
FReAKFrankly, what you're attempting to do may be beyond the capability of both LabVIEW and the digital I/O. At the very least, it's going to take quite a bit of work. On the transmit side, you're going to have break down characters into binary and then transmit them at a pretty precise rate. I'm not familiar with the CVS-1454 but a lot of digital I/O on NI devices is not hardware timed. Using software timing is going to be risky. You have the same issue on the receive end - just in reverse. I think that if I was forced to convert some digital I/O to serial, I'd try to use commerical parallel to serial converters. The digital I/O is similar to a parallel port and the converters handle all of the conversion, timing, and handshaking for you.
-
How to write ACPI device driver for Solaris 8 (SPARC Edition)
Hi, All,
I wonder how to write ACPI driver to access battery life,
can anyone help ? thanks!!I am having the similar problem identified in this thread.
OS: Sun Solaris 10 01/06
Hardware: Sun Blade 2500
PCI Memory card.
Problem: When driver moves more then 40 bytes via PIO from a PCI device memory card, the long words are swapped starting at 40 byte transfer size and greater.
device memory description:
static ddi_device_acc_attr_t sdram_access_attr =
DDI_DEVICE_ATTR_V0, /* Boilerplate value */
DDI_STRUCTURE_LE_ACC,
DDI_STRICTORDER_ACC /* Don't reorder accesses */
The user application does a read call, which goes to xxread. xxread calls physio( xxstrategy, bp, dev, B_READ, xxminphys, uio );
In xxstrategy the transfer is done using
ddi_mem_rep_get8(ucb->ucb_sdram_accHndl,
(uint8_t*) kaddr,
(uint8_t*) raddr,
(size_t) bp->b_resid),
(uint_t) DDI_DEV_AUTOINCR );
PCI Device memory is loaded with incrementing address (8bit), 0,1,2... This is confirmed using a PCI Bus Analyzer.
A read of 36 bytes or less returns:
03 02 01 00 07 06 05 04 ...
A read of 40 bytes returns:
07 06 05 04 03 02 01 00 ...
If I peek 1 byte at a time using ddi_get8(ucb->ucb_sdram_accHndl, ...) I get
00 01 02 03 04 05 06 07
Why are the long words swapped starting at 40 byte transfer size and greater? -
How to write driver programming in smartforms
hi Floks
<i>how to write driver programmig and how many types of driver programs available to trigger smartforms what are they . how to call the url in smartforms ?
help me out .thanking you ,</i>
with regards,
sureshHi
Try to get the Function module name from the smart form
how to find Driver program for a smartform
and now goto SE38 and create a progarm for calling the smartform
smartform driver program
Regards
Kathirve -
I have a Dynisco UPR700 instrument that has a modbus communication protocol, I use the lookout protocol driver modbus to communicate with it, but the lookout protocol driver gave me the information about "modbus exception response 2 (illegal data address)", how can I solve this problem? where can I set the right data address? Thanks!
Most likely you are trying to access a datamember address that is either not supported or non-existant on the UPR700.
Double check the address that you are writing/reading and make sure that it is supported.
Regards,
Chad Evans -
How to write Wireless PC Card Driver?
Hi, All,
Can anyone help me to find out how to write wireless pc card device driver?
Thanks !!There are [at least] two examples of PCMCIA dirvers in the DDK supplimentary suite. There is also an example of simple DLPI driver.
All you have to do is to combine those examples to get the PCMCIA DLPI driver and fine tune it to match your particular hardware. Any bells ring?
You will definitely need your card programming manual and/or software interface description for the last phase.
If you do not have one, you might get some open source (say, Linux or FreeBSD) driver for your card and do some code analysis to reveal the information you'll need.
Hope this helps...
Ilya. -
Does anyone know how to write on a NTFS drive?
Re: question???
How to write to a NTFS drive??
Maybe native support???I got this working just yesterday. Read this link for instructions:
http://www.offthehill.org/articles/2010/12/31/macfuse-for-64-bit-snow-leopard/
Install tuxera's MacFUSE binary from here: http://www.tuxera.com/mac/macfuse-core-10.5-2.1.9.dmg
Once you plug in your USB drive or an NTFS drive, the system will mount it read-only by default. You will need to "umount" it (as root, of course) and re-mount it with read-write permissions and a "noowners" option (I assume you're familiar with Unix commands and their options). I tried this today and it works, I can read/write to the NTFS drive on 64-bit snow leopard. -
Iphone 4 cdma ppp user hdr password how to write cdma work shop
iphone 4 cdma ppp user hdr password how to write im using cdma work shop
and how to enble dignostic portMy Yahoo email account worked just fine on my iPhone 4S for the last 2 months. Then this morning I started receiving the apple.imap.mail,yahoo error. I tried all of the steps above in solving the yahoo email issue including numerous hard re-sets and deletions of my yahoo account settings without any success. So I gave up trying to use the default Yahoo setup option. I added my Yahoo account back as an "other" type email account and then had the option to choose to set it up as a "POP" account instead of an IMAP type. I then just used the server settings recommended from Yahoo Help for a Yahoo Plus Email POP (or just google yahoo plus email pop settings). This works and I am back in business.
I'm not sure if this will work for yahoo mail classic accounts.
Frustrating that this issue seems to have been going on for quite awhile and Apple still as not made any acknowledgement of this issue or proposed a fix for those of us that can not resolve the issue with a reset. -
hi
can any1 over here help me out in how to establish connection between 2 RF modem's for data transfer , between client & server USing LABVIEW?
I want to establish a connection between 2 PC's through RF modem on client & server side & to set up PPP communication for data transfer.
(I have tried data transfer through RS-232 using TCP/IP whn the 2 PC's are connected over ethernet... which is working.
I also tried connecting loopback cable between 2 PC's COM port & geting data transfer using VIsa configure serial port & other visa functions ... which is working)
can u guide me how to establish connection between 2 RF modem's using LABview?
& how does the data transfer take place between 2 RF modems through RS-232?
is it using TCP/IP?
If you got any links to go abt this issue do send me related links .. or any examples .....
I am currently using Labview version 8.
Waiting in anticipation.. reply ASAP..
thanking you
Regards
Yogan..Howdy yogan,
Maybe you could clarify a few things for me, and we'll see how we can help ya. TCP/IP protocol occurs through an ethernet connection; RS-232 communication occurs through an RS-232 serial connection, typically through a cable that has a DB9 connector on both ends. Do you mean that the RF modems in question have the option to communicate via RS-232 and/or via TCP/IP ethernet? Specific information like the manufacturer of your RF modems, the model number of your RF modems, and how you connect the modems to the PC would enable us to give you more efficient support.
You can check our Instrument Driver Network (IDNet) to see if a plug-and-play/IVI driver already exists for your RF modem. (You'll need to know its manufacturer and model number.) In the case that you do find an IDNet driver for your modem, you can use this KnowledgeBase article for instructions on how to use the driver.
Another excellent resource to consider is the NI Example Finder. You can access this within LabVIEW by navigating to Help»Find Examples and then searching for serial or TCP/IP examples.
Message Edited by pBerg on 03-10-2008 04:35 PM
Warm regards,
pBerg -
Strange issue - unable to establish PPP with Cisco 887 VAG router on one particular ADSL line
I have a strange problem that I’m struggling to get to the bottom of with my ISP and wondered if anyone could help.
We have a site with an older Cisco 877 ADSL router which was working happily until a few weeks ago when the connection dropped suddenly (out-of-hours at 2am if that’s of any significance – made me think most likely something carrier/ISP related?) When connectivity was lost, the router could sync with the BT exchange (we are in the UK) but could not establish PPP.
We logged fault with our ISP – after some to’ing and fro’ing, they passed it onto BT and their engineers visited site, they fixed “a line fault” (we don’t get much detail on what was actually fixed) but we still could not establish connectivity – same thing, solid CD light but no PPP.
So, we replaced the router with another 877 – same again, solid CD but no PPP. We replaced all the cables and microfilter etc but no difference.
We tried a different Cisco router (a newer Cisco 887VAG) which, as I understand, uses a different modem chipset but no matter – PPP could still not be established. We tested this router on another ADSL line with the same ISP and it worked without issue, using the same ADSL account details, it was able to establish connectivity. So we figured this must still be a BT/ISP issue.
Since then we’ve had BT out again twice but they say there is no fault. The ISP say there is no issue with them. But we still cannot establish ADSL connectivity on this line, despite having tried 3 different ADSL routers and despite the fact the routers work with the same account details on another ADSL line.
The 887VAG router we have currently connected has 3G backup so that is keeping us going in the meantime and also means I can login to the router remotely to check on the ADSL status.
But I’m struggling to pinpoint where the problem may lie. Strangely, if I turn on PPP negotiation and authentication debug then I’m not actually seeing any output from it at all?
Yet, the ATM interface is up and shows packets being sent and received:
ATM0 is up, line protocol is up
Hardware is MPC ATMSAR, address is bc16.6596.9b00 (bia bc16.6596.9b00)
MTU 1600 bytes, sub MTU 1600, BW 704 Kbit/sec, DLY 520 usec,
reliability 255/255, txload 1/255, rxload 1/255
Encapsulation ATM, loopback not set
Keepalive not supported
Encapsulation(s): AAL5
4 maximum active VCs, 1024 VCs per VP, 1 current VCCs
VC Auto Creation Disabled.
VC idle disconnect time: 300 seconds
Last input 00:00:28, output 00:00:07, output hang never
Last clearing of "show interface" counters 6d23h
Input queue: 0/75/0/0 (size/max/drops/flushes); Total output drops: 0
Queueing strategy: Per VC Queueing
5 minute input rate 0 bits/sec, 0 packets/sec
5 minute output rate 0 bits/sec, 0 packets/sec
23886 packets input, 1676964 bytes, 0 no buffer
Received 0 broadcasts (0 IP multicasts)
0 runts, 0 giants, 0 throttles
0 input errors, 0 CRC, 0 frame, 0 overrun, 0 ignored, 0 abort
56469 packets output, 4418592 bytes, 0 underruns
0 output errors, 0 collisions, 6 interface resets
0 unknown protocol drops
0 output buffer failures, 0 output buffers swapped out
Does anyone have any ideas on where the problem may be and what more I can do to troubleshoot and provide the relevant evidence to our ISP (assuming it is an ISP/BT issue though the fact the same router works ok with the exact same details etc would seem to indicate it must be their issue!)Hi Jody,
thanks for the suggestions. Here's what I see from the ppp debugs (but I'm not sure how to interpret?)
Jan 6 14:50:22.838: pppoe_send_padi:
contiguous pak, size 74
00 01 09 00 AA AA 03 00 80 C2 00 07 00 00 FF FF
FF FF FF FF BC 16 65 96 9B 00 88 63 11 09 00 00
00 10 01 01 00 00 01 03 00 08 0C 00 00 01 00 00
04 A3 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 ...
Jan 6 14:50:22.878: PPPoE 0: I PADO R:0030.8810.000b L:bc16.6596.9b00 0/38 ATM0.1
contiguous pak, size 71
BC 16 65 96 9B 00 00 30 88 10 00 0B 88 63 11 07
00 00 00 33 01 03 00 08 0C 00 00 01 00 00 04 A3
01 02 00 1F 62 72 61 73 2D 72 65 64 37 2E 6C 73
2D 62 61 73 2D 42 32 32 36 45 34 37 30 39 45 30
31 34 5A 01 01 00 00
Jan 6 14:50:24.885: OUT PADR from PPPoE Session
contiguous pak, size 85
00 01 09 00 AA AA 03 00 80 C2 00 07 00 00 00 30
88 10 00 0B BC 16 65 96 9B 00 88 63 11 19 00 00
00 33 01 03 00 08 0C 00 00 01 00 00 04 A3 01 02
00 1F 62 72 61 73 2D 72 65 64 37 2E 6C 73 2D 62
61 73 2D 42 32 32 36 45 ...
Jan 6 14:50:35.125: OUT PADR from PPPoE Session
contiguous pak, size 85
00 01 09 00 AA AA 03 00 80 C2 00 07 00 00 00 30
88 10 00 0B BC 16 65 96 9B 00 88 63 11 19 00 00
00 33 01 03 00 08 0C 00 00 01 00 00 04 A3 01 02
00 1F 62 72 61 73 2D 72 65 64 37 2E 6C 73 2D 62
61 73 2D 42 32 32 36 45 ...
Jan 6 14:50:45.364: OUT PADR from PPPoE Session
contiguous pak, size 85
00 01 09 00 AA AA 03 00 80 C2 00 07 00 00 00 30
88 10 00 0B BC 16 65 96 9B 00 88 63 11 19 00 00
00 33 01 03 00 08 0C 00 00 01 00 00 04 A3 01 02
00 1F 62 72 61 73 2D 72 65 64 37 2E 6C 73 2D 62
61 73 2D 42 32 32 36 45 ...
Jan 6 14:50:55.603: OUT PADR from PPPoE Session
contiguous pak, size 85
00 01 09 00 AA AA 03 00 80 C2 00 07 00 00 00 30
88 10 00 0B BC 16 65 96 9B 00 88 63 11 19 00 00
00 33 01 03 00 08 0C 00 00 01 00 00 04 A3 01 02
00 1F 62 72 61 73 2D 72 65 64 37 2E 6C 73 2D 62
61 73 2D 42 32 32 36 45 ...
Jan 6 14:51:05.843: OUT PADR from PPPoE Session
contiguous pak, size 85
00 01 09 00 AA AA 03 00 80 C2 00 07 00 00 00 30
88 10 00 0B BC 16 65 96 9B 00 88 63 11 19 00 00
00 33 01 03 00 08 0C 00 00 01 00 00 04 A3 01 02
00 1F 62 72 61 73 2D 72 65 64 37 2E 6C 73 2D 62
61 73 2D 42 32 32 36 45 ...
Jan 6 14:51:16.114: OUT PADR from PPPoE Session
contiguous pak, size 85
00 01 09 00 AA AA 03 00 80 C2 00 07 00 00 00 30
88 10 00 0B BC 16 65 96 9B 00 88 63 11 19 00 00
00 33 01 03 00 08 0C 00 00 01 00 00 04 A3 01 02
00 1F 62 72 61 73 2D 72 65 64 37 2E 6C 73 2D 62
61 73 2D 42 32 32 36 45 ...
Jan 6 14:51:26.353: [0]PPPoE 0: O PADT R:0000.0000.0000 L:0000.0000.0000 0/38 ATM0.1
contiguous pak, size 74
00 01 09 00 AA AA 03 00 80 C2 00 07 00 00 00 00
00 00 00 00 00 00 00 00 00 00 88 63 11 A7 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 ...
Jan 6 14:51:46.576: pppoe_send_padi:
contiguous pak, size 74
00 01 09 00 AA AA 03 00 80 C2 00 07 00 00 FF FF
FF FF FF FF BC 16 65 96 9B 00 88 63 11 09 00 00
00 10 01 01 00 00 01 03 00 08 0C 00 00 01 00 00
04 A3 00 00 00 00 00 00 00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00 ...
Jan 6 14:51:46.608: PPPoE 0: I PADO R:0030.8810.000b L:bc16.6596.9b00 0/38 ATM0.1
contiguous pak, size 71
BC 16 65 96 9B 00 00 30 88 10 00 0B 88 63 11 07
00 00 00 33 01 03 00 08 0C 00 00 01 00 00 04 A3
01 02 00 1F 62 72 61 73 2D 72 65 64 37 2E 6C 73
2D 62 61 73 2D 42 32 32 36 45 34 37 30 39 45 30
31 34 5A 01 01 00 00
Provider wouldn't have bumped us from ADSL to VDSL - but here's the output of show controller vdsl 0:
Controller VDSL 0 is UP
Daemon Status: Up
XTU-R (DS) XTU-C (US)
Chip Vendor ID: 'BDCM' 'IFTN'
Chip Vendor Specific: 0x0000 0x71C8
Chip Vendor Country: 0xB500 0xB500
Modem Vendor ID: 'CSCO' ' '
Modem Vendor Specific: 0x4602 0x0000
Modem Vendor Country: 0xB500 0x0000
Serial Number Near: FCZ1111C08V C887VAG 15.2(4)M
Serial Number Far:
Modem Version Near: 15.2(4)M
Modem Version Far: 0x71c8
Modem Status: TC Sync (Showtime!)
DSL Config Mode: AUTO
Trained Mode: G.992.1 (ADSL) Annex A
TC Mode: ATM
Selftest Result: 0x00
DELT configuration: disabled
DELT state: not running
Trellis: ON ON
SRA: disabled disabled
SRA count: 0 0
Bit swap: enabled enabled
Bit swap count: 1 8
Line Attenuation: 54.5 dB 31.5 dB
Signal Attenuation: 54.5 dB 0.0 dB
Noise Margin: 6.7 dB 11.0 dB
Attainable Rate: 2132 kbits/s 888 kbits/s
Actual Power: 16.7 dBm 12.7 dBm
Total FECC: 546 0
Total ES: 6 0
Total SES: 0 0
Total LOSS: 0 0
Total UAS: 486 486
Total LPRS: 0 0
Total LOFS: 0 0
Total LOLS: 0 0
Full inits: 14
Failed full inits: 1
Short inits: 0
Failed short inits: 1
Firmware Source File Name (version)
VDSL user config flash:vdsl.bin-A2pv6C035d_d23j (10)
Modem FW Version: 110802_1752-4.02L.03.A2pv6C035d.d23j
Modem PHY Version: A2pv6C035d.d23j
Vendor Version:
DS Channel1 DS Channel0 US Channel1 US Channel0
Speed (kbps): 0 1664 0 704
SRA Previous Speed: 0 0 0 0
Previous Speed: 0 1600 0 736
Total Cells: 0 2786872 0 0
User Cells: 0 68 0 0
Reed-Solomon EC: 0 546 0 0
CRC Errors: 0 9 0 0
Header Errors: 0 10 0 0
Interleave (ms): 0.00 8.00 0.00 8.00
Actual INP: 0.00 1.12 0.00 1.28
Training Log : Stopped
Training Log Filename : flash:vdsllog.bin
And here's the output from the ATM and dialer interfaces:
interface ATM0
no ip address
ip flow ingress
no atm ilmi-keepalive
end
interface ATM0.1 point-to-point
ip flow ingress
pvc 0/38
pppoe-client dial-pool-number 2
end
interface Dialer2
description OUTSIDE
ip address negotiated
ip access-group firewall in
ip mtu 1492
ip flow ingress
ip nat outside
ip inspect DEFAULT100 out
ip virtual-reassembly in
encapsulation ppp
dialer pool 2
dialer-group 2
ppp authentication chap callin
ppp chap hostname ###removed###
ppp chap password ###removed###
no cdp enable
crypto map dcvpn
end
As I say though, config-wise, everything should be correct - the same router works fine on another line (which should also confirm the authentication details are correct - at least in as far as it matches what the ISP have on their RADIUS)
Any further thoughts? -
How to write data on to a location other than desktop or application server
Hi all,
I already posted this question.But i didn't get exact answer
Can anyone explain that how to write data on to a share drive located on other Nonsap server.Please I dont want to FTP the file.I dont want that solution.I need to write directly on to that Nonsap share drive..
Thanks,
BalajiI guess the only way is sending the file using a XI connection to the non sap system server,generate RFC adapters, inbound, outbound interfaces, using xml or soap or IDOC to move the file to that system.
-
How to wipe hard drive bc selling computer and want all passwords/personal info gone? etc
how to wipe hard drive bc selling computer and want all passwords/personal info gone?
You need to boot the computer from another source, e.g. a CD or an external drive. Then run Disk Utility, select the drive you want cleaned up, and run Erase. Note the security options: "write zeroes" will erase the drive completely.
-
Hi,
We have exadata x3-2. I am seeing this error in alert log file frequently.
The db version: 11.2.0.3 On RAC on Linux 5.8 x86-64Bit
Errors in file /d01/oracle/TEST/11.2.0/admin/TEST1_dbtest/diag/rdbms/prod/TEST1/trace/TEST1_reco_11909.trc:
ORA-01017: invalid username/password; logon denied
[Oracle][ODBC SQL Server Wire Protocol driver][SQL Server]Login failed for user 'RECOVER'. {28000,NativeErr = 18456}
ORA-02063: preceding 2 lines from HIS_CUST
The file /d01/oracle/TEST/11.2.0/admin/TEST1_dbtest/diag/rdbms/prod/TEST1/trace/TEST1_reco_11909.trc
Contains many repeated lines like below
*** 2015-01-21 06:34:40.209
ERROR, tran=21.24.51311, session#=1, ose=0:
ORA-01017: invalid username/password; logon denied
[Oracle][ODBC SQL Server Wire Protocol driver][SQL Server]Login failed for user 'RECOVER'. {28000,NativeErr = 18456}
ORA-02063: preceding 2 lines from HIS_CUST
Could any please help why is this happening.
ThanksHi,
You have customers who are running distributed transactions using a gateway which need to be rolled back. However, the gateway has not been correctly configured for distributed transactions. To roll back a transaction on the SQL*Server database a connection is made as the user defined in the parameter HS_FDS_RECOVERY_ACCOUNT in the gateway init<sid>.ora file but this user has not been created in the SQL*Server database with the password defined in HS_FDS_RECOVERY_PWD. This user also needs to own the transaction log table.
I assume you are using the Database Gateway for SQL*Server (DG4MSQL) as the Database Gateway for ODBC (DG4ODBC) doesn't support distributed transaction.
If you have access to My Oracle Support have a look at this note -
How to Setup DG4MSQL to Use Distributed Transactions (Doc ID 227011.1)
Otherwise, check the Gateway documentation.
Regards,
Mike -
How to write output from Keithley 220 to Excel using Labview
Hello, I have seen other posts that ask this question and was wondering if anyone has found the solution? I have downloaded the driver and seem to be able to communicate with the instrument. However, I am not very sure how to modify the driver to set the amperage and record the output to Excel.
Hi rachel-d,
It looks like that instrument driver is only one VI, and is not a certified driver. There seems to be a control for "source (A)" which may be what you're looking for as far as setting the amperage. Honestly, you may have better luck starting with a simple GPIB communication program and writing your own VI. You may need to check your device's manual for information on specific commands to set current values, etc. As for excel, you could use the Write to Measurement File Express VI and write your data to a text-based measurement file (.lvm) that is tab deliminated. You can then open this file with Excel. There are also examples you could look at in the NI Example Finder (Help > Find Examples).
Hope this helps!
Adam W
Applications Engineering
National Instruments
Maybe you are looking for
-
Entered wrong email setting up my ipad, now i cant get it to do anything
while setting up my ipad i mispelled my email address now I cant get it do anything, email, web, etc.
-
Need help with export PDF options
I want to go into edit job options and set everything for the highest possible quality exported PDF. Can someone please tell me how to set these options for the highest quality? Many thanks.
-
I purchased a new Nokia 6102i and it syncs perfectly with isync through the bluetooth port. Now I type in all my phone numbers in "Address Book" and all my appointments in "iCal" and synchronize these to my cell phone and if it ever gets lost or dest
-
Chat and email applications programmed in java
Can someone tell me where I can find some applications about chat and email with codes and tutorial? I have to work about these topics with some students of mine. Thanks Eugenia Mariani
-
I don't know what setting to change so that when I start typing my login (to an email account, etc), the previous entries do not show up. I want the field to start out and stay blank, and have me type the whoe string == This happened == Every time Fi